OEMvs original
Intended Use:The Temperature Probe is designed for measuring gas temperature and flow with Fisher & Paykel Healthcare MR850 and HC550 Humidifiers and Fisher & Paykel Healthcare Breathing Circuits.
Expected Service Life:3 years, if used in accordance with this User Instruction. Note: Service life may vary depending on usage pattern.
Reprocessing DiagramE.g.Tuffie 5 WipesTristel Wipes SystemMetrex Caviwipes 1Metrex CaviwipesPDI Sani-Cloth AF3PDI Super Sani-ClothClorox Hydrogen Peroxidee.g. STERIS Revital-Ox Resert HLD, 2.0 – 4.0% glutaraldehyde (e.g. Cidex, Metricide, ProCide-D), 0.95% glutaraldehyde/1.64% phenol(e.g. Sporicidin), 0.55% ortho‑phthalaldehyde (e.g. Cidex OPA), 7.5% hydrogen peroxide (e.g. Sporox).EquipmentSettingReprocessing CyclesSTERIS V-PRO 1Standard Cycle 78STERIS V-PRO 1 Plus Non-Lumen CycleSTERIS V-PRO 60STERIS V-PRO maXSterrad 100NXStandard Cycle25VP4 STERIZONECycle 178Setup DiagramTemperature Probe User InstructionsIntended Use:The Temperature Probe is designed for measuring gas temperature and flow with Fisher & Paykel Healthcare MR850 and HC550 Humidifiers and Fisher & Paykel Healthcare Breathing Circuits.Specification:Expected Service Life:3 years, if used in accordance with this User Instruction. Note: Service life may vary depending on usage pattern.Setup:Refer to the setup diagram.Before use remove and discard Protective Sleeve D, if present, from Chamber Probe B .Visually inspect entire product for damage before use. Discard if damaged.Push the Airway Probe A and Chamber Probe B into the Breathing Circuit making sure they are correctly located and pushed into place.The probe lead can be restrained usingBreathing Circuit Clips.If patient is in an incubator, refer to Breathing Circuit User Instructions for probe positioning information.Insert the Temperature Probe Connector C into the blue socket on the Humidifier.Perform ventilator leak test on the Breathing Circuit before use.Maintenance:Probe maintenance and accuracy checks should be routinely performed. For further information, refer to the MR850 or HC550 Technical Manual (available from your local Fisher & Paykel Healthcare representative).Reprocessing:The following parts are in contact with the gas path and can become contaminated with body fluids or expired gases:Airway Probe A, Chamber Probe B.Recommended cleaning procedures between uses (refer to reprocessing diagram):Remove any visible soil using a soft bristle brush, water and a mild non-abrasive detergent.Do not immerse the Temperature Probe Connector C in any liquid.Rinse in water after cleaning.Dry with a non-shedding cloth.Check for visible signs of damage. Discard if damaged. Repeat the cleaning steps if parts are not visually clean.Proceed to either step A, B, C or D depending on hospital guidelines.A. MANUAL DISINFECTION – WIPES Follow the wiping instructions supplied by the manufacturer.Check for visible signs of damage.Discard if damaged.If applicable, product can be packaged for reuse.B. MANUAL DISINFECTION – CHEMICALFollow the soaking instructions supplied by the manufacturer of the disinfection solution.Do not immerse the TemperatureProbe Connector C in any liquid.Cover container while soaking.Rinse in water after chemical soaking.Dry with a non-shedding cloth.Check for visible signs of damage.Discard if damaged.If applicable, product can be packaged for reuse.C. VAPORISED HYDROGEN PEROXIDE (VHP) STERILIZATIONFollow hospital guidelines for using the equipment (Equipment) and settings (Setting).D. ETHYLENE OXIDE (ETO) STERILIZATIONFollow hospital guidelines for process.Allow at least 12 hours aeration.Store as per hospital guidelines.Notes:Fisher & Paykel Healthcare do not recommend exceeding the number of reprocessing cycles stated (Reprocessing Cycles).The product is not designed for autoclave sterilization processes.Follow these recommended cleaning procedures and the user instructions of the cleaning agents or disinfection/sterilization equipment. It is the user’s responsibility to qualify any deviations from these procedures, both for disinfecting efficacy and physical effect.Warnings:The use of breathing circuits, chambers, other accessories or parts which are not approved by Fisher & Paykel Healthcare may impair performance or compromise safety.Failure to perform routine probe accuracy and visible damage checks may impair performance or compromise safety.Ensure that both Temperature Probe sensors are correctly and securely fitted. Failure to do so may result in gas temperatures in excess of 41 °C being delivered to the patient.Do not touch the glass tip of the ChamberProbe B during use; it may cause a skin burn.Gas mixes, such as helium-oxygen mixtures, that have different physical or thermal properties than air or air-oxygen mixture, may impair system performance or compromise safety.No automated method for cleaning and disinfection is recommended.California residents please be advised of the following, pursuant to Proposition 65:This product contains chemicals known to the State of California to cause cancer,birth defects and other reproductive harm.For more information, please visit: www.fphcare.com/prop65.Disposal:Dispose according to standard hospital guidelines for electrical and electronic equipment.Symbol Definition:Operating InstructionsDate of manufactureManufacturerDispose of product in correct mannerTransportation and storage humidity limitationTransportation and storage temperature limitationLot numberReference numberEuropean union authorised representativePrescription onlyCE Marking 93/42/EECMD symbolManufacturer Fisher & Paykel Healthcare Ltd, 15 Maurice Paykel Place, East Tamaki, Auckland 2013, PO Box 14 348 Panmure, Auckland 1741, New Zealand Tel: +64 9 574 0100Fax: +64 9 574 0158Email: info@fphcare.co.nzWeb: www.fphcare.com Importer/ DistributorREF 617135 REV E 2022-02 © 2022 Fisher & Paykel Healthcare LimitedDocuments / ResourcesFISHER PAYKEL 900MR860 Temperature Probe [pdf] Instructions900MR860, Temperature Probe, 900MR860 Temperature Probe, Probe, 900MR861, 900MR863, 900MR868, 900MR869References Quality & Regulatory | Fisher & Paykel Healthcare Home | Fisher & Paykel HealthcareUser ManualRelated PostsFISHER PAYKEL Vitera Sizing InstructionsFISHER PAYKEL Vitera Sizing Instructions Sizing guide instructions: Print this sizing guide onto US Letter-sized paper. Place your…FISHER PAYKEL RB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer User GuideRB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer User Guide RB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer Use your CoolDrawer™ as…FISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User GuideFISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User Guide Introduction Use your Cool Drawer™ as a…FISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User GuideQUICK REFERENCE GUIDE > RB9064S1 Integrated CoolDrawer™ Multitemperature Drawer Series 9 | Integrated Panel Ready RB9064S1 Integrated CoolDrawer…
Maintenance:Probe maintenance and accuracy checks should be routinely performed. For further information, refer to the MR850 or HC550 Technical Manual (available from your local Fisher & Paykel Healthcare representative).
10 FT LENGTH OEM Part Number Cross References: Manufacturer OEM Part # Curbell 5590 (CB-A400-3300) (8 ft) GE Healthcare > Marquette 2021406-001, 2025350-001 ...
OEMautomotive
8110 Series) and Alaris® PCA Module (PCA. Module, 8120 Series) . Use this ... Press Syringe Module soft key. 4. To view additional options, press PAGE.
e.g. STERIS Revital-Ox Resert HLD, 2.0 – 4.0% glutaraldehyde (e.g. Cidex, Metricide, ProCide-D), 0.95% glutaraldehyde/1.64% phenol(e.g. Sporicidin), 0.55% ortho‑phthalaldehyde (e.g. Cidex OPA), 7.5% hydrogen peroxide (e.g. Sporox).EquipmentSettingReprocessing CyclesSTERIS V-PRO 1Standard Cycle 78STERIS V-PRO 1 Plus Non-Lumen CycleSTERIS V-PRO 60STERIS V-PRO maXSterrad 100NXStandard Cycle25VP4 STERIZONECycle 178Setup DiagramTemperature Probe User InstructionsIntended Use:The Temperature Probe is designed for measuring gas temperature and flow with Fisher & Paykel Healthcare MR850 and HC550 Humidifiers and Fisher & Paykel Healthcare Breathing Circuits.Specification:Expected Service Life:3 years, if used in accordance with this User Instruction. Note: Service life may vary depending on usage pattern.Setup:Refer to the setup diagram.Before use remove and discard Protective Sleeve D, if present, from Chamber Probe B .Visually inspect entire product for damage before use. Discard if damaged.Push the Airway Probe A and Chamber Probe B into the Breathing Circuit making sure they are correctly located and pushed into place.The probe lead can be restrained usingBreathing Circuit Clips.If patient is in an incubator, refer to Breathing Circuit User Instructions for probe positioning information.Insert the Temperature Probe Connector C into the blue socket on the Humidifier.Perform ventilator leak test on the Breathing Circuit before use.Maintenance:Probe maintenance and accuracy checks should be routinely performed. For further information, refer to the MR850 or HC550 Technical Manual (available from your local Fisher & Paykel Healthcare representative).Reprocessing:The following parts are in contact with the gas path and can become contaminated with body fluids or expired gases:Airway Probe A, Chamber Probe B.Recommended cleaning procedures between uses (refer to reprocessing diagram):Remove any visible soil using a soft bristle brush, water and a mild non-abrasive detergent.Do not immerse the Temperature Probe Connector C in any liquid.Rinse in water after cleaning.Dry with a non-shedding cloth.Check for visible signs of damage. Discard if damaged. Repeat the cleaning steps if parts are not visually clean.Proceed to either step A, B, C or D depending on hospital guidelines.A. MANUAL DISINFECTION – WIPES Follow the wiping instructions supplied by the manufacturer.Check for visible signs of damage.Discard if damaged.If applicable, product can be packaged for reuse.B. MANUAL DISINFECTION – CHEMICALFollow the soaking instructions supplied by the manufacturer of the disinfection solution.Do not immerse the TemperatureProbe Connector C in any liquid.Cover container while soaking.Rinse in water after chemical soaking.Dry with a non-shedding cloth.Check for visible signs of damage.Discard if damaged.If applicable, product can be packaged for reuse.C. VAPORISED HYDROGEN PEROXIDE (VHP) STERILIZATIONFollow hospital guidelines for using the equipment (Equipment) and settings (Setting).D. ETHYLENE OXIDE (ETO) STERILIZATIONFollow hospital guidelines for process.Allow at least 12 hours aeration.Store as per hospital guidelines.Notes:Fisher & Paykel Healthcare do not recommend exceeding the number of reprocessing cycles stated (Reprocessing Cycles).The product is not designed for autoclave sterilization processes.Follow these recommended cleaning procedures and the user instructions of the cleaning agents or disinfection/sterilization equipment. It is the user’s responsibility to qualify any deviations from these procedures, both for disinfecting efficacy and physical effect.Warnings:The use of breathing circuits, chambers, other accessories or parts which are not approved by Fisher & Paykel Healthcare may impair performance or compromise safety.Failure to perform routine probe accuracy and visible damage checks may impair performance or compromise safety.Ensure that both Temperature Probe sensors are correctly and securely fitted. Failure to do so may result in gas temperatures in excess of 41 °C being delivered to the patient.Do not touch the glass tip of the ChamberProbe B during use; it may cause a skin burn.Gas mixes, such as helium-oxygen mixtures, that have different physical or thermal properties than air or air-oxygen mixture, may impair system performance or compromise safety.No automated method for cleaning and disinfection is recommended.California residents please be advised of the following, pursuant to Proposition 65:This product contains chemicals known to the State of California to cause cancer,birth defects and other reproductive harm.For more information, please visit: www.fphcare.com/prop65.Disposal:Dispose according to standard hospital guidelines for electrical and electronic equipment.Symbol Definition:Operating InstructionsDate of manufactureManufacturerDispose of product in correct mannerTransportation and storage humidity limitationTransportation and storage temperature limitationLot numberReference numberEuropean union authorised representativePrescription onlyCE Marking 93/42/EECMD symbolManufacturer Fisher & Paykel Healthcare Ltd, 15 Maurice Paykel Place, East Tamaki, Auckland 2013, PO Box 14 348 Panmure, Auckland 1741, New Zealand Tel: +64 9 574 0100Fax: +64 9 574 0158Email: info@fphcare.co.nzWeb: www.fphcare.com Importer/ DistributorREF 617135 REV E 2022-02 © 2022 Fisher & Paykel Healthcare LimitedDocuments / ResourcesFISHER PAYKEL 900MR860 Temperature Probe [pdf] Instructions900MR860, Temperature Probe, 900MR860 Temperature Probe, Probe, 900MR861, 900MR863, 900MR868, 900MR869References Quality & Regulatory | Fisher & Paykel Healthcare Home | Fisher & Paykel HealthcareUser ManualRelated PostsFISHER PAYKEL Vitera Sizing InstructionsFISHER PAYKEL Vitera Sizing Instructions Sizing guide instructions: Print this sizing guide onto US Letter-sized paper. Place your…FISHER PAYKEL RB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer User GuideRB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer User Guide RB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer Use your CoolDrawer™ as…FISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User GuideFISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User Guide Introduction Use your Cool Drawer™ as a…FISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User GuideQUICK REFERENCE GUIDE > RB9064S1 Integrated CoolDrawer™ Multitemperature Drawer Series 9 | Integrated Panel Ready RB9064S1 Integrated CoolDrawer…
OEMfull form
Symbol Definition:Operating InstructionsDate of manufactureManufacturerDispose of product in correct mannerTransportation and storage humidity limitationTransportation and storage temperature limitationLot numberReference numberEuropean union authorised representativePrescription onlyCE Marking 93/42/EECMD symbolManufacturer Fisher & Paykel Healthcare Ltd, 15 Maurice Paykel Place, East Tamaki, Auckland 2013, PO Box 14 348 Panmure, Auckland 1741, New Zealand Tel: +64 9 574 0100Fax: +64 9 574 0158Email: info@fphcare.co.nzWeb: www.fphcare.com Importer/ DistributorREF 617135 REV E 2022-02 © 2022 Fisher & Paykel Healthcare LimitedDocuments / ResourcesFISHER PAYKEL 900MR860 Temperature Probe [pdf] Instructions900MR860, Temperature Probe, 900MR860 Temperature Probe, Probe, 900MR861, 900MR863, 900MR868, 900MR869References Quality & Regulatory | Fisher & Paykel Healthcare Home | Fisher & Paykel HealthcareUser ManualRelated PostsFISHER PAYKEL Vitera Sizing InstructionsFISHER PAYKEL Vitera Sizing Instructions Sizing guide instructions: Print this sizing guide onto US Letter-sized paper. Place your…FISHER PAYKEL RB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer User GuideRB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer User Guide RB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer Use your CoolDrawer™ as…FISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User GuideFISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User Guide Introduction Use your Cool Drawer™ as a…FISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User GuideQUICK REFERENCE GUIDE > RB9064S1 Integrated CoolDrawer™ Multitemperature Drawer Series 9 | Integrated Panel Ready RB9064S1 Integrated CoolDrawer…
OEMmeaning in sales
FISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User Guide Introduction Use your Cool Drawer™ as a…
Disposal:Dispose according to standard hospital guidelines for electrical and electronic equipment.Symbol Definition:Operating InstructionsDate of manufactureManufacturerDispose of product in correct mannerTransportation and storage humidity limitationTransportation and storage temperature limitationLot numberReference numberEuropean union authorised representativePrescription onlyCE Marking 93/42/EECMD symbolManufacturer Fisher & Paykel Healthcare Ltd, 15 Maurice Paykel Place, East Tamaki, Auckland 2013, PO Box 14 348 Panmure, Auckland 1741, New Zealand Tel: +64 9 574 0100Fax: +64 9 574 0158Email: info@fphcare.co.nzWeb: www.fphcare.com Importer/ DistributorREF 617135 REV E 2022-02 © 2022 Fisher & Paykel Healthcare LimitedDocuments / ResourcesFISHER PAYKEL 900MR860 Temperature Probe [pdf] Instructions900MR860, Temperature Probe, 900MR860 Temperature Probe, Probe, 900MR861, 900MR863, 900MR868, 900MR869References Quality & Regulatory | Fisher & Paykel Healthcare Home | Fisher & Paykel HealthcareUser ManualRelated PostsFISHER PAYKEL Vitera Sizing InstructionsFISHER PAYKEL Vitera Sizing Instructions Sizing guide instructions: Print this sizing guide onto US Letter-sized paper. Place your…FISHER PAYKEL RB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer User GuideRB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer User Guide RB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer Use your CoolDrawer™ as…FISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User GuideFISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User Guide Introduction Use your Cool Drawer™ as a…FISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User GuideQUICK REFERENCE GUIDE > RB9064S1 Integrated CoolDrawer™ Multitemperature Drawer Series 9 | Integrated Panel Ready RB9064S1 Integrated CoolDrawer…
OEMexample
Leggett & Platt Plymouth K-132 Manual Online: Remote Control Programming. - 1 REMOTE TO OPERATE 1 BASE STEP 1 Plug base into power outlet.
Manufacturer Fisher & Paykel Healthcare Ltd, 15 Maurice Paykel Place, East Tamaki, Auckland 2013, PO Box 14 348 Panmure, Auckland 1741, New Zealand Tel: +64 9 574 0100Fax: +64 9 574 0158Email: info@fphcare.co.nzWeb: www.fphcare.com Importer/ Distributor
OEMbrand
Warnings:The use of breathing circuits, chambers, other accessories or parts which are not approved by Fisher & Paykel Healthcare may impair performance or compromise safety.Failure to perform routine probe accuracy and visible damage checks may impair performance or compromise safety.Ensure that both Temperature Probe sensors are correctly and securely fitted. Failure to do so may result in gas temperatures in excess of 41 °C being delivered to the patient.Do not touch the glass tip of the ChamberProbe B during use; it may cause a skin burn.Gas mixes, such as helium-oxygen mixtures, that have different physical or thermal properties than air or air-oxygen mixture, may impair system performance or compromise safety.No automated method for cleaning and disinfection is recommended.California residents please be advised of the following, pursuant to Proposition 65:This product contains chemicals known to the State of California to cause cancer,birth defects and other reproductive harm.For more information, please visit: www.fphcare.com/prop65.Disposal:Dispose according to standard hospital guidelines for electrical and electronic equipment.Symbol Definition:Operating InstructionsDate of manufactureManufacturerDispose of product in correct mannerTransportation and storage humidity limitationTransportation and storage temperature limitationLot numberReference numberEuropean union authorised representativePrescription onlyCE Marking 93/42/EECMD symbolManufacturer Fisher & Paykel Healthcare Ltd, 15 Maurice Paykel Place, East Tamaki, Auckland 2013, PO Box 14 348 Panmure, Auckland 1741, New Zealand Tel: +64 9 574 0100Fax: +64 9 574 0158Email: info@fphcare.co.nzWeb: www.fphcare.com Importer/ DistributorREF 617135 REV E 2022-02 © 2022 Fisher & Paykel Healthcare LimitedDocuments / ResourcesFISHER PAYKEL 900MR860 Temperature Probe [pdf] Instructions900MR860, Temperature Probe, 900MR860 Temperature Probe, Probe, 900MR861, 900MR863, 900MR868, 900MR869References Quality & Regulatory | Fisher & Paykel Healthcare Home | Fisher & Paykel HealthcareUser ManualRelated PostsFISHER PAYKEL Vitera Sizing InstructionsFISHER PAYKEL Vitera Sizing Instructions Sizing guide instructions: Print this sizing guide onto US Letter-sized paper. Place your…FISHER PAYKEL RB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer User GuideRB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer User Guide RB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer Use your CoolDrawer™ as…FISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User GuideFISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User Guide Introduction Use your Cool Drawer™ as a…FISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User GuideQUICK REFERENCE GUIDE > RB9064S1 Integrated CoolDrawer™ Multitemperature Drawer Series 9 | Integrated Panel Ready RB9064S1 Integrated CoolDrawer…
QUICK REFERENCE GUIDE > RB9064S1 Integrated CoolDrawer™ Multitemperature Drawer Series 9 | Integrated Panel Ready RB9064S1 Integrated CoolDrawer…
This website is an independent publication and is neither affiliated with nor endorsed by any of the trademark owners. The "Bluetooth®" word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. The "Wi-Fi®" word mark and logos are registered trademarks owned by the Wi-Fi Alliance. Any use of these marks on this website does not imply any affiliation with or endorsement.
Baxter Evacuated Container - 1A8504 ; Sold out. $71.99 USD ; SKU 1A8504 ; Stock # : 200415 ; Manufacturer # : 1A8504 ; Manufacturer : Baxter.
OEMproduct
Setup DiagramTemperature Probe User InstructionsIntended Use:The Temperature Probe is designed for measuring gas temperature and flow with Fisher & Paykel Healthcare MR850 and HC550 Humidifiers and Fisher & Paykel Healthcare Breathing Circuits.Specification:Expected Service Life:3 years, if used in accordance with this User Instruction. Note: Service life may vary depending on usage pattern.Setup:Refer to the setup diagram.Before use remove and discard Protective Sleeve D, if present, from Chamber Probe B .Visually inspect entire product for damage before use. Discard if damaged.Push the Airway Probe A and Chamber Probe B into the Breathing Circuit making sure they are correctly located and pushed into place.The probe lead can be restrained usingBreathing Circuit Clips.If patient is in an incubator, refer to Breathing Circuit User Instructions for probe positioning information.Insert the Temperature Probe Connector C into the blue socket on the Humidifier.Perform ventilator leak test on the Breathing Circuit before use.Maintenance:Probe maintenance and accuracy checks should be routinely performed. For further information, refer to the MR850 or HC550 Technical Manual (available from your local Fisher & Paykel Healthcare representative).Reprocessing:The following parts are in contact with the gas path and can become contaminated with body fluids or expired gases:Airway Probe A, Chamber Probe B.Recommended cleaning procedures between uses (refer to reprocessing diagram):Remove any visible soil using a soft bristle brush, water and a mild non-abrasive detergent.Do not immerse the Temperature Probe Connector C in any liquid.Rinse in water after cleaning.Dry with a non-shedding cloth.Check for visible signs of damage. Discard if damaged. Repeat the cleaning steps if parts are not visually clean.Proceed to either step A, B, C or D depending on hospital guidelines.A. MANUAL DISINFECTION – WIPES Follow the wiping instructions supplied by the manufacturer.Check for visible signs of damage.Discard if damaged.If applicable, product can be packaged for reuse.B. MANUAL DISINFECTION – CHEMICALFollow the soaking instructions supplied by the manufacturer of the disinfection solution.Do not immerse the TemperatureProbe Connector C in any liquid.Cover container while soaking.Rinse in water after chemical soaking.Dry with a non-shedding cloth.Check for visible signs of damage.Discard if damaged.If applicable, product can be packaged for reuse.C. VAPORISED HYDROGEN PEROXIDE (VHP) STERILIZATIONFollow hospital guidelines for using the equipment (Equipment) and settings (Setting).D. ETHYLENE OXIDE (ETO) STERILIZATIONFollow hospital guidelines for process.Allow at least 12 hours aeration.Store as per hospital guidelines.Notes:Fisher & Paykel Healthcare do not recommend exceeding the number of reprocessing cycles stated (Reprocessing Cycles).The product is not designed for autoclave sterilization processes.Follow these recommended cleaning procedures and the user instructions of the cleaning agents or disinfection/sterilization equipment. It is the user’s responsibility to qualify any deviations from these procedures, both for disinfecting efficacy and physical effect.Warnings:The use of breathing circuits, chambers, other accessories or parts which are not approved by Fisher & Paykel Healthcare may impair performance or compromise safety.Failure to perform routine probe accuracy and visible damage checks may impair performance or compromise safety.Ensure that both Temperature Probe sensors are correctly and securely fitted. Failure to do so may result in gas temperatures in excess of 41 °C being delivered to the patient.Do not touch the glass tip of the ChamberProbe B during use; it may cause a skin burn.Gas mixes, such as helium-oxygen mixtures, that have different physical or thermal properties than air or air-oxygen mixture, may impair system performance or compromise safety.No automated method for cleaning and disinfection is recommended.California residents please be advised of the following, pursuant to Proposition 65:This product contains chemicals known to the State of California to cause cancer,birth defects and other reproductive harm.For more information, please visit: www.fphcare.com/prop65.Disposal:Dispose according to standard hospital guidelines for electrical and electronic equipment.Symbol Definition:Operating InstructionsDate of manufactureManufacturerDispose of product in correct mannerTransportation and storage humidity limitationTransportation and storage temperature limitationLot numberReference numberEuropean union authorised representativePrescription onlyCE Marking 93/42/EECMD symbolManufacturer Fisher & Paykel Healthcare Ltd, 15 Maurice Paykel Place, East Tamaki, Auckland 2013, PO Box 14 348 Panmure, Auckland 1741, New Zealand Tel: +64 9 574 0100Fax: +64 9 574 0158Email: info@fphcare.co.nzWeb: www.fphcare.com Importer/ DistributorREF 617135 REV E 2022-02 © 2022 Fisher & Paykel Healthcare LimitedDocuments / ResourcesFISHER PAYKEL 900MR860 Temperature Probe [pdf] Instructions900MR860, Temperature Probe, 900MR860 Temperature Probe, Probe, 900MR861, 900MR863, 900MR868, 900MR869References Quality & Regulatory | Fisher & Paykel Healthcare Home | Fisher & Paykel HealthcareUser ManualRelated PostsFISHER PAYKEL Vitera Sizing InstructionsFISHER PAYKEL Vitera Sizing Instructions Sizing guide instructions: Print this sizing guide onto US Letter-sized paper. Place your…FISHER PAYKEL RB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer User GuideRB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer User Guide RB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer Use your CoolDrawer™ as…FISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User GuideFISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User Guide Introduction Use your Cool Drawer™ as a…FISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User GuideQUICK REFERENCE GUIDE > RB9064S1 Integrated CoolDrawer™ Multitemperature Drawer Series 9 | Integrated Panel Ready RB9064S1 Integrated CoolDrawer…
Expected Service Life:3 years, if used in accordance with this User Instruction. Note: Service life may vary depending on usage pattern.Setup:Refer to the setup diagram.Before use remove and discard Protective Sleeve D, if present, from Chamber Probe B .Visually inspect entire product for damage before use. Discard if damaged.Push the Airway Probe A and Chamber Probe B into the Breathing Circuit making sure they are correctly located and pushed into place.The probe lead can be restrained usingBreathing Circuit Clips.If patient is in an incubator, refer to Breathing Circuit User Instructions for probe positioning information.Insert the Temperature Probe Connector C into the blue socket on the Humidifier.Perform ventilator leak test on the Breathing Circuit before use.Maintenance:Probe maintenance and accuracy checks should be routinely performed. For further information, refer to the MR850 or HC550 Technical Manual (available from your local Fisher & Paykel Healthcare representative).Reprocessing:The following parts are in contact with the gas path and can become contaminated with body fluids or expired gases:Airway Probe A, Chamber Probe B.Recommended cleaning procedures between uses (refer to reprocessing diagram):Remove any visible soil using a soft bristle brush, water and a mild non-abrasive detergent.Do not immerse the Temperature Probe Connector C in any liquid.Rinse in water after cleaning.Dry with a non-shedding cloth.Check for visible signs of damage. Discard if damaged. Repeat the cleaning steps if parts are not visually clean.Proceed to either step A, B, C or D depending on hospital guidelines.A. MANUAL DISINFECTION – WIPES Follow the wiping instructions supplied by the manufacturer.Check for visible signs of damage.Discard if damaged.If applicable, product can be packaged for reuse.B. MANUAL DISINFECTION – CHEMICALFollow the soaking instructions supplied by the manufacturer of the disinfection solution.Do not immerse the TemperatureProbe Connector C in any liquid.Cover container while soaking.Rinse in water after chemical soaking.Dry with a non-shedding cloth.Check for visible signs of damage.Discard if damaged.If applicable, product can be packaged for reuse.C. VAPORISED HYDROGEN PEROXIDE (VHP) STERILIZATIONFollow hospital guidelines for using the equipment (Equipment) and settings (Setting).D. ETHYLENE OXIDE (ETO) STERILIZATIONFollow hospital guidelines for process.Allow at least 12 hours aeration.Store as per hospital guidelines.Notes:Fisher & Paykel Healthcare do not recommend exceeding the number of reprocessing cycles stated (Reprocessing Cycles).The product is not designed for autoclave sterilization processes.Follow these recommended cleaning procedures and the user instructions of the cleaning agents or disinfection/sterilization equipment. It is the user’s responsibility to qualify any deviations from these procedures, both for disinfecting efficacy and physical effect.Warnings:The use of breathing circuits, chambers, other accessories or parts which are not approved by Fisher & Paykel Healthcare may impair performance or compromise safety.Failure to perform routine probe accuracy and visible damage checks may impair performance or compromise safety.Ensure that both Temperature Probe sensors are correctly and securely fitted. Failure to do so may result in gas temperatures in excess of 41 °C being delivered to the patient.Do not touch the glass tip of the ChamberProbe B during use; it may cause a skin burn.Gas mixes, such as helium-oxygen mixtures, that have different physical or thermal properties than air or air-oxygen mixture, may impair system performance or compromise safety.No automated method for cleaning and disinfection is recommended.California residents please be advised of the following, pursuant to Proposition 65:This product contains chemicals known to the State of California to cause cancer,birth defects and other reproductive harm.For more information, please visit: www.fphcare.com/prop65.Disposal:Dispose according to standard hospital guidelines for electrical and electronic equipment.Symbol Definition:Operating InstructionsDate of manufactureManufacturerDispose of product in correct mannerTransportation and storage humidity limitationTransportation and storage temperature limitationLot numberReference numberEuropean union authorised representativePrescription onlyCE Marking 93/42/EECMD symbolManufacturer Fisher & Paykel Healthcare Ltd, 15 Maurice Paykel Place, East Tamaki, Auckland 2013, PO Box 14 348 Panmure, Auckland 1741, New Zealand Tel: +64 9 574 0100Fax: +64 9 574 0158Email: info@fphcare.co.nzWeb: www.fphcare.com Importer/ DistributorREF 617135 REV E 2022-02 © 2022 Fisher & Paykel Healthcare LimitedDocuments / ResourcesFISHER PAYKEL 900MR860 Temperature Probe [pdf] Instructions900MR860, Temperature Probe, 900MR860 Temperature Probe, Probe, 900MR861, 900MR863, 900MR868, 900MR869References Quality & Regulatory | Fisher & Paykel Healthcare Home | Fisher & Paykel HealthcareUser ManualRelated PostsFISHER PAYKEL Vitera Sizing InstructionsFISHER PAYKEL Vitera Sizing Instructions Sizing guide instructions: Print this sizing guide onto US Letter-sized paper. Place your…FISHER PAYKEL RB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer User GuideRB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer User Guide RB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer Use your CoolDrawer™ as…FISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User GuideFISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User Guide Introduction Use your Cool Drawer™ as a…FISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User GuideQUICK REFERENCE GUIDE > RB9064S1 Integrated CoolDrawer™ Multitemperature Drawer Series 9 | Integrated Panel Ready RB9064S1 Integrated CoolDrawer…
OEMcompany
Duracell Ultra Lithium Pack of 2 · Capacity: 1500 mAh · Battery Chemistry: Lithium · Warranty: 1 YEAR.
Brand: Kangaroo · Condition: New Other · SKU: BN221 · Model: 773662 · Lot# BN221 17.3.C · MPN: 773662 ...
Trimbio supply a wide range of New & Reconditioned Medical / Rehabilitation / Physiotherapy Products - We also carry out Nationwide Service & Repair of ...
Reprocessing:The following parts are in contact with the gas path and can become contaminated with body fluids or expired gases:
AHP Medical Supplies Ltd., operating out of United Kingdom, provides one of the largest medical equipment supplier in UK as compared to all the other medical ...
FISHER PAYKEL Vitera Sizing Instructions Sizing guide instructions: Print this sizing guide onto US Letter-sized paper. Place your…
by HR Blackwell · 1970 · Cited by 16 — ..949 .902. F5 .950 .950. 1.013 .977. LC1 .902 .902 .945 .911. LC2 ... X Target C48.4.1 (S). O Target C48.4.1. APRIL 1970. Contrast Rendition for Pencil ...
Find great prices on Stryker stretcher parts for Stryker DX-LX, EZ Pro, MX & Power Pro cots. https://t.co/DN7Ad7gWDi.
Notes:Fisher & Paykel Healthcare do not recommend exceeding the number of reprocessing cycles stated (Reprocessing Cycles).The product is not designed for autoclave sterilization processes.Follow these recommended cleaning procedures and the user instructions of the cleaning agents or disinfection/sterilization equipment. It is the user’s responsibility to qualify any deviations from these procedures, both for disinfecting efficacy and physical effect.Warnings:The use of breathing circuits, chambers, other accessories or parts which are not approved by Fisher & Paykel Healthcare may impair performance or compromise safety.Failure to perform routine probe accuracy and visible damage checks may impair performance or compromise safety.Ensure that both Temperature Probe sensors are correctly and securely fitted. Failure to do so may result in gas temperatures in excess of 41 °C being delivered to the patient.Do not touch the glass tip of the ChamberProbe B during use; it may cause a skin burn.Gas mixes, such as helium-oxygen mixtures, that have different physical or thermal properties than air or air-oxygen mixture, may impair system performance or compromise safety.No automated method for cleaning and disinfection is recommended.California residents please be advised of the following, pursuant to Proposition 65:This product contains chemicals known to the State of California to cause cancer,birth defects and other reproductive harm.For more information, please visit: www.fphcare.com/prop65.Disposal:Dispose according to standard hospital guidelines for electrical and electronic equipment.Symbol Definition:Operating InstructionsDate of manufactureManufacturerDispose of product in correct mannerTransportation and storage humidity limitationTransportation and storage temperature limitationLot numberReference numberEuropean union authorised representativePrescription onlyCE Marking 93/42/EECMD symbolManufacturer Fisher & Paykel Healthcare Ltd, 15 Maurice Paykel Place, East Tamaki, Auckland 2013, PO Box 14 348 Panmure, Auckland 1741, New Zealand Tel: +64 9 574 0100Fax: +64 9 574 0158Email: info@fphcare.co.nzWeb: www.fphcare.com Importer/ DistributorREF 617135 REV E 2022-02 © 2022 Fisher & Paykel Healthcare LimitedDocuments / ResourcesFISHER PAYKEL 900MR860 Temperature Probe [pdf] Instructions900MR860, Temperature Probe, 900MR860 Temperature Probe, Probe, 900MR861, 900MR863, 900MR868, 900MR869References Quality & Regulatory | Fisher & Paykel Healthcare Home | Fisher & Paykel HealthcareUser ManualRelated PostsFISHER PAYKEL Vitera Sizing InstructionsFISHER PAYKEL Vitera Sizing Instructions Sizing guide instructions: Print this sizing guide onto US Letter-sized paper. Place your…FISHER PAYKEL RB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer User GuideRB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer User Guide RB36S25MKIWN1 Integrated Cool Drawer Multi-Temperature Drawer Use your CoolDrawer™ as…FISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User GuideFISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User Guide Introduction Use your Cool Drawer™ as a…FISHER and PAYKEL RB9064S1 Integrated CoolDrawer Multi Temperature Drawer User GuideQUICK REFERENCE GUIDE > RB9064S1 Integrated CoolDrawer™ Multitemperature Drawer Series 9 | Integrated Panel Ready RB9064S1 Integrated CoolDrawer…