GE Healthcare Senographe DS Service Information and Procedures Class A SIP-A 0459 The page behind contains quick access links to commonly used information. Use these Favorite Links when attempting to find information. 2385072-16-8EN Revision 1 Copyright© 2012 by General Electric Company inc. All rights reserved. GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN This page is blank. Page no. 2 coverDS-SIP-Class-A.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Favorite Links for Field Engineers Favorite Links for Field Engineers Use these links for quick access to frequently used information in the SIP: Functional diagrams Acquisition System Entry Block Diagram on page 74 Product history, compatibility, and applicability Introduction on page 51 FRU/Component locations Control Station on page 201 Gantry - MPCB on page 188 Generator Cabinet on page 211 Pre-installation procedures Scenario PRE A001 - Pre-installation Procedures on page 363 Installation procedures Scenario PHY A001 - Physical Installation on page 389 Scenario ELE A001 - Electrical Installation on page 537 Corrective maintenance Error Messages on page 829 Diagnostics on page 941 Troubleshooting guides on page 1007 Disassembly/Reassembly on page 1093 Scenario CAL A001 - Image Quality Full Calibration Process from Scratch on page 819 Configuration guide on page 1639 Calibration guides on page 1647 Verification checks on page 1727 Long-term shutdown procedure Job Card CARE A001 - Detector protection during system shutdown on page 1761 Planned Maintenance Scenario PM A001 - Planned Maintenance Steering Guide on page 1765 Page no. 3 Favorites for FE.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Favorite Links for Field Engineers This page is blank. Page no. 4 Favorites for FE.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Table of Contents Table of Contents Favorite Links for Field Engineers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 5 Chapter 1: Safety Language Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X-ray Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Definition of Warnings and Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 23 25 Chapter 2: Publication Presentation 1. Scope and Applicability of the Publication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 2. Content of this Publication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 3. Publication Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 4. How to Navigate Using Acrobat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Acronyms Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 35 39 Chapter 3: System Description Sub-Systems and Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 1. System Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 2. System Component Description .......................................... 45 3. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product history and compatibility. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Functional Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 51 71 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 2. Correspondence between Functions and Components . . . . . . . . . . . . . . . . . . . . . . . . . . 72 3. Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 4. Acquisition System Entry Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 5. MPCB Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 6. Column Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 7. Compression Arm Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 8. Tube Head Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 9. Collimator Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 10. Main Distribution and Conditioner Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 11. Generator Block Diagram ............................................... 81 12. Control Station Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Senographe Operations - How to.... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 91 1. How to Use the X-ray Console. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 2. X-ray Console Menu Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 Page no. 5 SenoDS_SIP-Class-ATOC.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Table of Contents 3. How to Use the Browser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 4. How to Use the Command Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 5. How to Use the Service Desktop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 6. How to Use the Error Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 7. How to Use Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 8. How to Use the Image Quality Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 9. How to Use Calibration Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131 10. How to Use the Configuration Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135 11. How to Use the Utilities Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 12. How to View the Status Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 13. How to Use the Calculator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 14. Comparison between CS V1/V2 and CS V3/V4 Service Desktop . . . . . . . . . . . . . . . . . FRU/Component Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FRU/Component Index - Control Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FRU/Component Index - Gantry ............................................ FRU/Component Index - Generator Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FRU/Component Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 145 149 156 177 185 1. Scope. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185 2. Navigation Principles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185 3. Acquisition System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tools Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 219 1. Mechanical Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 2. Specified Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226 3. Consumable Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Central Listing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236 239 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239 2. Generator Cabinet Jumpers and Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239 3. Generator Cabinet Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279 4. Gantry Board Indicators and Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 286 5. Gantry MPCB Switches and Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable Lay-out and Pin-out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 297 299 1. Gantry Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299 2. AWS Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322 3. Generator Cabinet Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322 Chapter 4: Pre-Installation System Requirements 1. Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324 2. IEC60601-1-2 Electromagnetic Standards Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . 327 3. Noise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332 Page no. 6 SenoDS_SIP-Class-ATOC.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Table of Contents 4. Structural Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332 5. Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334 6. Door Lights and Safety Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338 7. Room Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338 8. Planning for Radiation Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 339 9. Planning for Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 340 10. Room Layout Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341 11. Insite Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359 12. Networking Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359 13. Telephone Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359 14. Associated Review Workstations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359 Chapter 5: Pre-Installation Procedures Scenario PRE A001 - Pre-installation Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Scenario PRE A002 - Pre-purchase Site Visit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Scenario PRE A003 - Installation Planning Visit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Scenario PRE A004 - Pre-Delivery Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PRE A001 - Checking for Damage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363 365 367 369 371 Chapter 6: Physical Installation Job Card LOTO A001 - Lock-Out / Tag-Out (LOTO) Procedures . . . . . . . . . . . . . . . . . . . . . Scenario PHY A001 - Physical Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PHY A001 - Unpacking the Gantry and Generator Cabinet . . . . . . . . . . . . . . . . . Job Card PHY A002 - Unpacking the Control Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PHY A003 - Gantry and Control Station Installation . . . . . . . . . . . . . . . . . . . . . . . Job Card PHY A004 - Radiation Screen Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PHY A005 - Bucky Support Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PHY A006 - Regulatory and Safety Labelling . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PHY A009 - Opposite Side Rotative Arm Installation . . . . . . . . . . . . . . . . . . . . . . Job Card PHY A010 - Mount LCD Monitor on Control Station . . . . . . . . . . . . . . . . . . . . . . . Job Card PHY A011 - Trackball Option Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PHY A012 - X-ray Console Cable Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PHY A014 - Connect Gantry to Control Station. . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PHY A015 - HT Cable Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PHY A016 - AC Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PHY A018 - Room Lamps and Door Configuration. . . . . . . . . . . . . . . . . . . . . . . . Job Card PHY A030 - Generator and Gantry Disconnection Reconnection . . . . . . . . . . . . Job Card PHY A040 - Remove/Reinstall Control Station Covers. . . . . . . . . . . . . . . . . . . . . Job Card PHY A042 - Remove/Reinstall Generator Covers . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PHY A044 - Remove/Reinstall Gantry Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 7: Electrical Installation Page no. 7 SenoDS_SIP-Class-ATOC.fm 377 389 391 397 401 405 409 411 415 435 443 451 455 467 469 475 479 503 513 523 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Table of Contents Scenario ELE A001 - Electrical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A005 - Check Supply Voltages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A006 - First System Power-On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A007 - Line Resistance Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A008 - Configuring the 21-inch 3MP Monitor . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A009 - Generator Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A010 - Set Lift Travel Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A012 - X-ray Parameter Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A013 - AWS Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A015 - Gantry Functional Checks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A017 - Manual Compression Check and Calibration . . . . . . . . . . . . . . . . . . Job Card ELE A020 - Declare and Set Printers (Filming Devices). . . . . . . . . . . . . . . . . . . . Job Card ELE A021 - Networking Connection and Configuration. . . . . . . . . . . . . . . . . . . . Job Card ELE A022 - Declare Network Hosts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A023 - Declare Worklist Hosts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A024 - Declare Performed Procedure Step Hosts. . . . . . . . . . . . . . . . . . . . . Job Card ELE A028 - Collimation Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A031 - AOP Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A032 – IQ Tools Flat Field Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A037 - Image Acquisition and ACR Score . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A038 - AOP Mode and SNR Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A039 - Compliance with Germany for Detector Dose. . . . . . . . . . . . . . . . . . Job Card ELE A042 - Bar Code Scanner (Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A043 - AWS Monitor Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A044 - Install User Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A050 - Changing Senographe Internal IP Addresses . . . . . . . . . . . . . . . . . . Job Card ELE A052 - Back-up/Restore Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A060 - Image Receptor Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A065 - Trackball Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card ELE A067 - Repeat and Reject Analysis Configuration . . . . . . . . . . . . . . . . . . . . Job Card ELE A071 - Installation of CAD option on AWS . . . . . . . . . . . . . . . . . . . . . . . . . . 537 541 543 547 549 561 565 571 573 579 583 585 625 663 671 675 679 693 699 705 707 711 715 729 755 757 771 781 787 791 793 Chapter 8: System Identification and Follow-up Form LBK A001 - System Configuration Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 797 Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets 801 Chapter 9: Corrective Maintenance Procedures Scenario CAL A001 - Image Quality Full Calibration Process from Scratch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Scenario PDR A001 - Post-D/R Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 819 821 Error Messages 829 ERR SUB A001 - Generator Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ERR SUB A003 - Gantry Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 831 851 Page no. 8 SenoDS_SIP-Class-ATOC.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Table of Contents ERR SUB A005 - AWS Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 935 ERR SUB A007 - IDC Error Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 937 Diagnostics 941 Job Card DIAG A1000 - Gantry Diagnostic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card DIAG A001 - AWS Sun-VTS Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card DIAG A002 - AWS Ethernet Port Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card DIAG A003 - AWS File System and SCSI Board Diagnostics . . . . . . . . . . . . . . . Job Card DIAG A005 - Error Log Retrieval. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card DIAG A010 - No Lift or Rotation Movement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 943 977 987 989 993 1005 Troubleshooting guides 1007 Job Card TSG A001 - AWS Troubleshooting - No Display on Power Up . . . . . . . . . . . . . . 1009 Job Card TSG A007 - Digital Detector Firmware Corrupted . . . . . . . . . . . . . . . . . . . . . . . . . 1015 Job Card TSG A009 - AWS Bootup Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1017 Job Card TSG A010 - Troubleshooting Bad Pixel Calibration Failure. . . . . . . . . . . . . . . . . 1019 Job Card TSG A012 - Use of DB9 Adaptors to Reduce Intermittent IDC or ADS Communication Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1029 Job Card TSG A015 - Lift Movement Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1035 Job Card TSG A016 - Rotation Movement Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . 1059 Job Card TSG A020 - Generator Power-Up Sequence Flow Charts . . . . . . . . . . . . . . . . . . 1069 Job Card TSG A027 - 080/011 Error Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1083 Job Card TSG M028 - E24 084/008 Error Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . 1085 Disassembly/Reassembly 1093 Job Card D/R A121 - Optical Fiber (Gantry to Generator). . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A141 - Image Receptor/Digital Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A142 - Detector Power Supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A150 - System Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A189 - Interface Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A190 - Gantry CPU Board. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A191 - PDU Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A192 - Arm Distribution Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A193 - AC/DC Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A194 - AC/DC Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A201 - Lift Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A202 - Upper Optical Fork . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A203 - Lower Optical Fork . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A204 - Lift Potentiometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A205 - Lift Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A206A - Lift Gas Spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A207 - Lift Belt. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A208 - Gantry Curtains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A210 - Gantry cover replacement guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A212 - Gantry Readout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page no. 9 SenoDS_SIP-Class-ATOC.fm 1097 1099 1107 1109 1125 1131 1137 1143 1147 1153 1161 1167 1171 1175 1179 1183 1189 1193 1197 1215 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Table of Contents Job Card D/R A215 - Arm Control Keypad Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A216 - Arm Control Keypads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A221 - Rotation Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A222 - Clutch and Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A223 - Rotation Optical Fork . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A224 - Gas Spring for Rotation Worm Gear . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A227 - Rotation Potentiometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A228 - Rotation Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A229 - Rotation Brake . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A230 - Rotation Gas Spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A232 - Lift Screw Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A233 - Lift Screw Assembly Top Brake . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A243 - Compression Potentiometer and Cable . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A244 - Compression Motor with Encoder and Compression Belt . . . . . . . . Job Card D/R A245 - Manual Compression Belt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A246 - Manual Compression Brake. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A247 - Motorized Compression Brake . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A248 - Force Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A249 - W304 Cable for Paddle Recognition . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A250 - Compression Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A251 - Paddle Holder Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job card D/R A252 - Compression Trolley Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A255 - Bucky . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job card D/R A256 - Bucky Top Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job card D/R A258 - Bucky Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A261 - X-ray Tube Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A264 - Tilt Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A265 - Tilt Motor and Drive Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A266 - Tube Tilt Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A280 - Collimator Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A285 - Collimator Filter Wheel Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A287 - Collimator DC-DC Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A288 - Collimator Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A290 - FOV Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A291 - Stop Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A292 - Tube Tilt Pivots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A311 - AWS Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A312 - Mouse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A313 - Trackball . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A314 - External CD-RW Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A315 - International Keyboard. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A316 - SB-150 CD-ROM Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1217 1219 1223 1227 1231 1235 1239 1243 1247 1251 1255 1279 1289 1297 1299 1301 1309 1313 1319 1323 1331 1337 1339 1343 1347 1353 1357 1361 1365 1369 1375 1379 1383 1391 1395 1397 1401 1417 1427 1439 1443 1457 Page no. 10 SenoDS_SIP-Class-ATOC.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Table of Contents Job Card D/R A317 - Radiation Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A318 - LCD Monitor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A319 - Rotative Arm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A321 - IDC Computer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A322 - RJ-45 Service Network Patch Panel . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A331 - UPS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A332 - UPS Battery Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A335 - AWS (U20) Motherboard Battery (V3 Control Stations only) . . . . . . Job Card D/R A401 - Generator CPU Board 400PL3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A402 - Generator CPU Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A403 - Capacitor Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A404 - HV Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A405 - HV Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A406 - Generator Command Board 400-PL1 . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A407 - Generator Interface Board 400-PL2. . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A408 - Generator Supply Command Board 200-PL2 . . . . . . . . . . . . . . . . . . . Job Card D/R A409 - Relay Board 200-PL4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A410 - Inverter Board 300-PL1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A411 - Mains Distribution Board 200-PL1. . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A412 - Anode Starter Board 300-PL2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A413 - BT Power Supply 400-T1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A414 - Power Line Filter Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A415 - Generator Board CPU EEPROMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card D/R A421 - Conditioner Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1463 1469 1483 1503 1517 1521 1529 1537 1543 1549 1553 1559 1565 1569 1577 1583 1591 1595 1601 1609 1613 1617 1625 1633 Configuration guide 1639 Job Card CFG A001 - Software Reload. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1641 Job Card CFG A070 - Deactivate Contrast Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1645 Calibration guides 1647 Job Card CAL A001 - Heater Current Scale Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card CAL A003 - X-Ray Tube Focal Bias Voltage Scale Factor . . . . . . . . . . . . . . . . . . Job Card CAL A007 - Automatic X-ray Tube Warm-Up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card CAL A009 - X-Ray Tube mA Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card CAL A011 - Calibration of kV Scale Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card CAL A012 - X-Ray Tube Heater Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card CAL A021 - Arm Rotation Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card CAL A027 - Tube Tilt Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card CAL A029 - Collimator Format Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card CAL A031 - Lift Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card CAL A041 - Bad Pixel Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card CAL A043 - Detector Gain Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card CAL A045 - Conversion Factor Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card CAL A046 - Half-Value Layer Measurement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page no. 11 SenoDS_SIP-Class-ATOC.fm 1649 1655 1661 1663 1667 1673 1679 1681 1683 1687 1693 1697 1701 1703 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Table of Contents Job Card CAL A048 - Calibration of Compression Force Sensor . . . . . . . . . . . . . . . . . . . . Job Card CAL A049 - Compression Paddle Offset Calibration . . . . . . . . . . . . . . . . . . . . . . Job Card CAL A050 - Compression Thickness Calibration . . . . . . . . . . . . . . . . . . . . . . . . . Job Card CAL A051 - AOP Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card CAL A053 - mAs Non-linearity Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1709 1711 1721 1723 1725 Verification checks 1727 Job Card CHK A001 - Boot/Init and Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card CHK A003 - UPS Batteries. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card CHK A004 - DICOM Printer Adjustments and Checks . . . . . . . . . . . . . . . . . . . . . Job Card CHK A011 - Check kVp settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card CHK A013 - Check mA and mAs settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1729 1737 1741 1745 1755 Chapter 10: Long Term Shutdown Procedures Job Card CARE A001 - Detector protection during system shutdown . . . . . . . . . . . . . . . . 1761 Chapter 11: Planned Maintenance Procedures Scenario PM A001 - Planned Maintenance Steering Guide . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PM A101 - Site Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PM A155 - General System Inspection Checks. . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PM A201 - Gantry operational checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PM A205 - Mechanical checks and lubrication . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PM A254 - Tube Head Fan Filter Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PM A255 - Collimator and Tube Head Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PM A300 - 21-inch 3MP Monitor Luminance Checks . . . . . . . . . . . . . . . . . . . . . . Job Card PM A407 - Check HV Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PM A425 - IDC Air Filter Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Job Card PM A428 - Conditioner Coolant Level Check and Top-up . . . . . . . . . . . . . . . . . . Job Card PM A429 - Conditioner Air Filter Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . End of the Publication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1765 1773 1775 1777 1779 1783 1787 1793 1801 1803 1805 1807 1809 Page no. 12 SenoDS_SIP-Class-ATOC.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Safety CHAPTER 1 SAFETY This chapter contains information and warnings related to safety. Page no. 13 Chap-Safety.fm Chapter 1 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Safety This page is blank. Chapter 1 Page no. 14 Chap-Safety.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Language Warning Language Warning ПРЕДУПРЕЖДЕНИЕ (BG) 警告 (ZH-CN) 警告 (ZH-HK) 警告 (ZH-TW) UPOZORENJE (HR) Chapter 1 Това упътване за работа е налично само на английски език. • Ако доставчикът на услугата на клиента изиска друг език, задължение на клиента е да осигури превод. • Не използвайте оборудването, преди да сте се консултирали и разбрали упътването за работа. • Неспазването на това предупреждение може да доведе до нараняване на доставчика на услугата, оператора или пациентa в резултат на токов удар, механична или друга опасност. 本维修手册仅提供英文版本。 • 如果客户的维修服务人员需要非英文版本,则客户需自行提供翻译服 务。 • 未详细阅读和完全理解本维修手册之前,不得进行维修。 • 忽略本警告可能对维修服务人员、操作人员或患者造成电击、机械伤害 或其他形式的伤害。 本服務手冊僅提供英文版本。 • 倘若客戶的服務供應商需要英文以外之服務手冊,客戶有責任提供翻譯 服務。 • 除非已參閱本服務手冊及明白其內容,否則切勿嘗試維修設備。 • 不遵從本警告或會令服務供應商、網絡供應商或病人受到觸電、機械性 或其他的危險。 本維修手冊僅有英文版。 • 若客戶的維修廠商需要英文版以外的語言,應由客戶自行提供翻譯服 務。 • 請勿試圖維修本設備,除非 您已查閱並瞭解本維修手冊。 • 若未留意本警告,可能導致維修廠商、操作員或病患因觸電、機械或其 他危險而受傷。 Ovaj servisni priručnik dostupan je na engleskom jeziku. • Ako davatelj usluge klijenta treba neki drugi jezik, klijent je dužan osigurati prijevod. • Ne pokušavajte servisirati opremu ako niste u potpunosti pročitali i razumjeli ovaj servisni priručnik. • Zanemarite li ovo upozorenje, može doći do ozljede davatelja usluge, operatera ili pacijenta uslijed strujnog udara, mehaničkih ili drugih rizika. Page no. 15 language warning.fm Chapter 1 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Language Warning VÝSTRAHA (CS) ADVARSEL (DA) WAARSCHUWING (NL) WARNING (EN) HOIATUS (ET) Chapter 1 Tento provozní návod existuje pouze v anglickém jazyce. • V případě, že externí služba zákazníkům potřebuje návod v jiném jazyce, je zajištění překladu do odpovídajícího jazyka úkolem zákazníka. • Nesnažte se o údržbu tohoto zařízení, aniž byste si přečetli tento provozní návod a pochopili jeho obsah. • V případě nedodržování této výstrahy může dojít k poranění pracovníka prodejního servisu, obslužného personálu nebo pacientů vlivem elektrického proudu, respektive vlivem mechanických či jiných rizik. Denne servicemanual findes kun på engelsk. • Hvis en kundes tekniker har brug for et andet sprog end engelsk, er det kundens ansvar at sørge for oversættelse. • Forsøg ikke at servicere udstyret uden at læse og forstå denne servicemanual. • Manglende overholdelse af denne advarsel kan medføre skade på grund af elektrisk stød, mekanisk eller anden fare for teknikeren, operatøren eller patienten. Deze onderhoudshandleiding is enkel in het Engels verkrijgbaar. • Als het onderhoudspersoneel een andere taal vereist, dan is de klant verantwoordelijk voor de vertaling ervan. • Probeer de apparatuur niet te onderhouden alvorens deze onderhoudshandleiding werd geraadpleegd en begrepen is. • Indien deze waarschuwing niet wordt opgevolgd, zou het onderhoudspersoneel, de operator of een patiënt gewond kunnen raken als gevolg van een elektrische schok, mechanische of andere gevaren. This service manual is available in English only. • If a customer's service provider requires a language other than english, it is the customer's responsibility to provide translation services. • Do not attempt to service the equipment unless this service manual has been consulted and is understood. • Failure to heed this warning may result in injury to the service provider, operator or patient from electric shock, mechanical or other hazards. See teenindusjuhend on saadaval ainult inglise keeles • Kui klienditeeninduse osutaja nõuab juhendit inglise keelest erinevas keeles, vastutab klient tõlketeenuse osutamise eest. • Ärge üritage seadmeid teenindada enne eelnevalt käesoleva teenindusjuhendiga tutvumist ja sellest aru saamist. • Käesoleva hoiatuse eiramine võib põhjustada teenuseosutaja, operaatori või patsiendi vigastamist elektrilöögi, mehaanilise või muu ohu tagajärjel. Page no. 16 language warning.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Language Warning VAROITUS (FI) ATTENTION (FR) WARNUNG (DE) ΠΡΟΕΙΔΟΠΟΙΗΣΗ (EL) FIGYELMEZTETÉS (HU) Tämä huolto-ohje on saatavilla vain englanniksi. • Jos asiakkaan huoltohenkilöstö vaatii muuta kuin englanninkielistä materiaalia, tarvittavan käännöksen hankkiminen on asiakkaan vastuulla. • Älä yritä korjata laitteistoa ennen kuin olet varmasti lukenut ja ymmärtänyt tämän huolto-ohjeen. • Mikäli tätä varoitusta ei noudateta, seurauksena voi olla huoltohenkilöstön, laitteiston käyttäjän tai potilaan vahingoittuminen sähköiskun, mekaanisen vian tai muun vaaratilanteen vuoksi. Ce manuel d’installation et de maintenance est disponible uniquement en anglais. • Si le technicien d'un client a besoin de ce manuel dans une langue autre que l'anglais, il incombe au client de le faire traduire. • Ne pas tenter d'intervenir sur les équipements tant que ce manuel d’installation et de maintenance n'a pas été consulté et compris. • Le non-respect de cet avertissement peut entraîner chez le technicien, l'opérateur ou le patient des blessures dues à des dangers électriques, mécaniques ou autres. Diese Serviceanleitung existiert nur in englischer Sprache. • Falls ein fremder Kundendienst eine andere Sprache benötigt, ist es Aufgabe des Kunden für eine entsprechende Übersetzung zu sorgen. • Versuchen Sie nicht diese Anlage zu warten, ohne diese Serviceanleitung gelesen und verstanden zu haben. • Wird diese Warnung nicht beachtet, so kann es zu Verletzungen des Kundendiensttechnikers, des Bedieners oder des Patienten durch Stromschläge, mechanische oder sonstige Gefahren kommen. Το παρόν εγχειρίδιο σέρβις διατίθεται μόνο στα αγγλικά. • Εάν ο τεχνικός σέρβις ενός πελάτη απαιτεί το παρόν εγχειρίδιο σε γλώσσα εκτός των αγγλικών, αποτελεί ευθύνη του πελάτη να παρέχει τις υπηρεσίες μετάφρασης. • Μην επιχειρήσετε την εκτέλεση εργασιών σέρβις στον εξοπλισμό αν δεν έχετε συμβουλευτεί και κατανοήσει το παρόν εγχειρίδιο σέρβις. • Αν δεν προσέξετε την προειδοποίηση αυτή, ενδέχεται να προκληθεί τραυματισμός στον τεχνικό σέρβις, στο χειριστή ή στον ασθενή από ηλεκτροπληξία, μηχανικούς ή άλλους κινδύνους. Ezen karbantartási kézikönyv kizárólag angol nyelven érhető el. • Ha a vevő szolgáltatója angoltól eltérő nyelvre tart igényt, akkor a vevő felelőssége a fordítás elkészíttetése. • Ne próbálja elkezdeni használni a berendezést, amíg a karbantartási kézikönyvben leírtakat nem értelmezték. • Ezen figyelmeztetés figyelmen kívül hagyása a szolgáltató, működtető vagy a beteg áramütés, mechanikai vagy egyéb veszélyhelyzet miatti sérülését eredményezheti. Page no. 17 language warning.fm Chapter 1 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Language Warning AÐVÖRUN (IS) AVVERTENZA (IT) 警告 (JA) 경고 (KO) BRDINJUMS (LV) ĮSPĖJIMAS (LT) Chapter 1 Þessi þjónustuhandbók er aðeins fáanleg á ensku. • Ef að þjónustuveitandi viðskiptamanns þarfnast annas tungumáls en ensku, er það skylda viðskiptamanns að skaffa tungumálaþjónustu. • Reynið ekki að afgreiða tækið nema að þessi þjónustuhandbók hefur verið skoðuð og skilin. • Brot á sinna þessari aðvörun getur leitt til meiðsla á þjónustuveitanda, stjórnanda eða sjúklings frá raflosti, vélrænu eða öðrum áhættum. Il presente manuale di manutenzione è disponibile soltanto in lingua inglese. • Se un addetto alla manutenzione richiede il manuale in una lingua diversa, il cliente è tenuto a provvedere direttamente alla traduzione. • Procedere alla manutenzione dell'apparecchiatura solo dopo aver consultato il presente manuale ed averne compreso il contenuto. • Il mancato rispetto della presente avvertenza potrebbe causare lesioni all'addetto alla manutenzione, all'operatore o ai pazienti provocate da scosse elettriche, urti meccanici o altri rischi. このサービスマニュアルには英語版しかありません。 • サービスを担当される業者が英語以外の言語を要求される場合、翻訳 作業はその業者の責任で行うものとさせていただきます。 • このサービスマニュアルを熟読し理解せずに、装置のサービスを行わ ないでください。 • この警告に従わない場合、サービスを担当される方、操作員あるいは 患者さんが、感電や機械的又はその他の危険により負傷する可能性が あります。 본 서비스 매뉴얼은 영어로만 이용하실 수 있습니다 . • 고객의 서비스 제공자가 영어 이외의 언어를 요구할 경우 , 번역 서비 스를 제공하는 것은 고객의 책임입니다 . • 본 서비스 매뉴얼을 참조하여 숙지하지 않은 이상 해당 장비를 수리하 려고 시도하지 마십시오 . • 본 경고 사항에 유의하지 않으면 전기 쇼크, 기계적 위험, 또는 기타 위 험으로 인해 서비스 제공자 , 사용자 또는 환자에게 부상을 입힐 수 있 습니다 . Šī apkopes rokasgrāmata ir pieejama tikai angļu valodā. • Ja klienta apkopes sniedzējam nepieciešama informācija citā valodā, klienta pienākums ir nodrošināt tulkojumu. • Neveiciet aprīkojuma apkopi bez apkopes rokasgrāmatas izlasīšanas un saprašanas. • Šī brīdinājuma neievērošanas rezultātā var rasties elektriskās strāvas trieciena, mehānisku vai citu faktoru izraisītu traumu risks apkopes sniedzējam, operatoram vai pacientam. Šis eksploatavimo vadovas yra tik anglų kalba. • Jei kliento paslaugų tiekėjas reikalauja vadovo kita kalba – ne anglų, suteikti vertimo paslaugas privalo klientas. • Nemėginkite atlikti įrangos techninės priežiūros, jei neperskaitėte ar nesupratote šio eksploatavimo vadovo. • Jei nepaisysite šio įspėjimo, galimi paslaugų tiekėjo, operatoriaus ar paciento sužalojimai dėl elektros šoko, mechaninių ar kitų pavojų. Page no. 18 language warning.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Language Warning ADVARSEL (NO) OSTRZEŻENIE (PL) ATENÇÃO (PT-BR) ATENÇÃO (PT-PT) ATENŢIE (RO) Denne servicehåndboken finnes bare på engelsk. • Hvis kundens serviceleverandør har bruk for et annet språk, er det kundens ansvar å sørge for oversettelse. • Ikke forsøk å reparere utstyret uten at denne servicehåndboken er lest og forstått. • Manglende hensyn til denne advarselen kan føre til at serviceleverandøren, operatøren eller pasienten skades på grunn av elektrisk støt, mekaniske eller andre farer. Niniejszy podręcznik serwisowy dostępny jest jedynie w języku angielskim. • Jeśli serwisant klienta wymaga języka innego niż angielski, zapewnienie usługi tłumaczenia jest obowiązkiem klienta. • Nie próbować serwisować urządzenia bez zapoznania się z niniejszym podręcznikiem serwisowym i zrozumienia go. • Niezastosowanie się do tego ostrzeżenia może doprowadzić do obrażeń serwisanta, operatora lub pacjenta w wyniku porażenia prądem elektrycznym, zagrożenia mechanicznego bądź innego. Este manual de assistência técnica encontra-se disponível unicamente em inglês. • Se outro serviço de assistência técnica solicitar a tradução deste manual, caberá ao cliente fornecer os serviços de tradução. • Não tente reparar o equipamento sem ter consultado e compreendido este manual de assistência técnica. • A não observância deste aviso pode ocasionar ferimentos no técnico, operador ou paciente decorrentes de choques elétricos, mecânicos ou outros. Este manual de assistência técnica só se encontra disponível em inglês. • Se qualquer outro serviço de assistência técnica solicitar este manual noutro idioma, é da responsabilidade do cliente fornecer os serviços de tradução. • Não tente reparar o equipamento sem ter consultado e compreendido este manual de assistência técnica. • O não cumprimento deste aviso pode colocar em perigo a segurança do técnico, do operador ou do paciente devido a choques eléctricos, mecânicos ou outros. Acest manual de service este disponibil doar în limba engleză. • Dacă un furnizor de servicii pentru clienţi necesită o altă limbă decât cea engleză, este de datoria clientului să furnizeze o traducere. • Nu încercaţi să reparaţi echipamentul decât ulterior consultării şi înţelegerii acestui manual de service. • Ignorarea acestui avertisment ar putea duce la rănirea depanatorului, operatorului sau pacientului în urma pericolelor de electrocutare, mecanice sau de altă natură. Page no. 19 language warning.fm Chapter 1 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Language Warning ОСТОРОЖНО! (RU) UPOZORENJE (SR) UPOZORNENIE (SK) ATENCION (ES) VARNING (SV) Chapter 1 Данное руководство по техническому обслуживанию представлено только на английском языке. • Если сервисному персоналу клиента необходимо руководство не на английском, а на каком-то другом языке, клиенту следует самостоятельно обеспечить перевод. • Перед техническим обслуживанием оборудования обязательно обратитесь к данному руководству и поймите изложенные в нем сведения. • Несоблюдение требований данного предупреждения может привести к тому, что специалист по техобслуживанию, оператор или пациент получит удар электрическим током, механическую травму или другое повреждение. Ovo servisno uputstvo je dostupno samo na engleskom jeziku. • Ako klijentov serviser zahteva neki drugi jezik, klijent je dužan da obezbedi prevodilačke usluge. • Ne pokušavajte da opravite uređaj ako niste pročitali i razumeli ovo servisno uputstvo. • Zanemarivanje ovog upozorenja može dovesti do povređivanja servisera, rukovaoca ili pacijenta usled strujnog udara ili mehaničkih i drugih opasnosti. Tento návod na obsluhu je k dispozícii len v angličtine. • Ak zákazníkov poskytovateľ služieb vyžaduje iný jazyk ako angličtinu, poskytnutie prekladateľských služieb je zodpovednosťou zákazníka. • Nepokúšajte sa o obsluhu zariadenia, kým si neprečítate návod na obluhu a neporozumiete mu. • Zanedbanie tohto upozornenia môže spôsobiť zranenie poskytovateľa služieb, obsluhujúcej osoby alebo pacienta elektrickým prúdom, mechanické alebo iné ohrozenie. Este manual de servicio sólo existe en inglés. • Si el encargado de mantenimiento de un cliente necesita un idioma que no sea el inglés, el cliente deberá encargarse de la traducción del manual. • No se deberá dar servicio técnico al equipo, sin haber consultado y comprendido este manual de servicio. • La no observancia del presente aviso puede dar lugar a que el proveedor de servicios, el operador o el paciente sufran lesiones provocadas por causas eléctricas, mecánicas o de otra naturaleza. Den här servicehandboken finns bara tillgänglig på engelska. . • Om en kunds servicetekniker har behov av ett annat språk än engelska, ansvarar kunden för att tillhandahålla översättningstjänster. • Försök inte utföra service på utrustningen om du inte har läst och förstår den här servicehandboken. • Om du inte tar hänsyn till den här varningen kan det resultera i skador på serviceteknikern, operatören eller patienten till följd av elektriska stötar, mekaniska faror eller andra faror. Page no. 20 language warning.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Language Warning OPOZORILO (SL) DIKKAT (TR) Ta servisni priročnik je na voljo samo v angleškem jeziku. • Če ponudnik storitve stranke potrebuje priročnik v drugem jeziku, mora stranka zagotoviti prevod. • Ne poskušajte servisirati opreme, če tega priročnika niste v celoti prebrali in razumeli. • Če tega opozorila ne upoštevate, se lahko zaradi električnega udara, mehanskih ali drugih nevarnosti poškoduje ponudnik storitev, operater ali bolnik. Bu servis kılavuzunun sadece ingilizcesi mevcuttur. • Eğer müşteri teknisyeni bu kılavuzu ingilizce dışında bir başka lisandan talep ederse, bunu tercüme ettirmek müşteriye düşer. • Servis kılavuzunu okuyup anlamadan ekipmanlara müdahale etmeyiniz. • Bu uyarıya uyulmaması, elektrik, mekanik veya diğer tehlikelerden dolayı teknisyen, operatör veya hastanın yaralanmasına yol açabilir. Page no. 21 language warning.fm Chapter 1 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Language Warning This page is blank. Chapter 1 Page no. 22 language warning.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN X-ray Warning X-ray Warning Chapter 1 ATTENTION Les appareils à rayons X sont dangereux à la fois pour le patient et pour le manipulateur si les mesures de protection ne sont pas strictement appliquees Bien que cet appareil soit construit selon les normes de sécurité les plus sévères, la source de rayonnement X représente un danger lorsque le manipulateur est non qualifié ou non averti. Une exposition excessive au rayonnement X entraîne des dommages à l’organisme. Par conséquent, toutes les précautions doivent être prises pour éviter que les personnes non autorisées ou non qualifiées utilisent cet appareil créant ainsi un danger pour les autres et pour elles-mêmes. Avant chaque manipulation, les personnes qualifiées et autorisées à se servir de cet appareil doivent se renseigner sur les mesures de protection établies par la Commission Internationale de la Protection Radiologique, Annales 60 : Recommandations de la Commission Internationale sur la Protection Radiologique et les normes nationales en vigueur. Elles doivent également avoir reçu une formation sur l’utilisation de ce matériel. WARNING X-ray equipment is dangerous to both patient and operator unless measures of protection are strictly observed Though this equipment is built to the highest standards of electrical and mechanical safety, the useful X-ray beam becomes a source of danger in the hands of the unauthorized or unqualified operator. Excessive exposure to x-radiation causes damage to human tissue. Therefore, adequate precautions must be taken to prevent unauthorized or unqualified persons from operating this equipment or exposing themselves or others to its radiation. Before operation, persons qualified and authorized to operate this equipment should be familiar with the Recommendations of the International Commission on Radiological Protection, contained in Annals Number 60 of the ICRP, and with applicable national standards and should have been trained in use of the equipment. ATENCION Los aparatos de rayos X son peligrosos para el paciente y el manipulador cuando las normas de proteccion no estan observadas Aunque este aparato está construido según las normas de seguridad más estrictas, la radiación X constituye un peligro al ser manipulado por personas no autorizadas o incompetentes. Una exposición excesiva a la radiación X puede causar daños al organismo. Por consiguiente, se deberán tomar todas las precauciones necesarias para evitar que las personas incompetentes o no autorizadas utilicen este aparato, lo que sería un peligro para los demás y para sí mismas. Antes de efectuar las manipulaciones, las personas habilitadas y competentes en el uso de este aparato, deberán informarse sobre las normas de protección fijadas por la Comisión Internacional de la Protección Radiológica, Anales No 60: Recomendaciónes de la Comisión Internacional sobre la Protección Radiológica y normas nacionales y deben haber sido formatas en el uso de este equipo. ACHTUNG Röntgenapparate sind eine gefahr fÜr patienten sowie bedienungspersonal, wenn die geltenden sicherheitsvorkehrungen nicht genau beachtet werden Dieser Apparat entspricht in seiner Bauweise strengsten elektrischen und mechanischen Sichereitsnormen, doch in den Händen unbefugter oder unqualifizierter Personen wird er zu einer Gefahrenquelle. Übermäßige Röntgenbestrahlung ist für den menschlichen Organismus schädlich. Deswegen sind hinreichende Vorsichtsmaßnahmen erforderlich, um zu verhindern, daßunbefugte oder unqualifizierte Personen solche Geräte bedienen oder sich selbst und andere Personen deren Bestrahlung aussetzen können. Vor Inbetriebnahme dieses Apparats sollte sich das qualifizierte und befugte Bedienungspersonal mit den geltenden Kriterien für den gefahrlosen Strahleneinsatz durch sorgfältiges Studium des Hefts Nr. 60 der Internationalen Kommission für Strahlenschutz (ICRP) vertraut machen: Empfehlungen der Internationalen Kommission für Strahlenschutz und anderer nationaler Normenbehörden. Page no. 23 radiation warning.fm Chapter 1 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN X-ray Warning This page is blank. Chapter 1 Page no. 24 radiation warning.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Definition of Warnings and Notes Definition of Warnings and Notes Chapter 1 DANGER Indicates an imminently hazardous situation that, if not avoided, will result in death or serious injury. WARNING Indicates a potentially hazardous situation that, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation that, if not avoided, may result in minor or moderate injury. ! Notice: Used for instructions to the Operator to prevent damage to property. Note: Used to draw attention to information that is important for the Operator to know. Page no. 25 Definition-warning-notes.fm Chapter 1 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Definition of Warnings and Notes Meaning of Symbols The following symbols may appear on parts of the Senographe System. Alternating current Earth (ground) Dangerous voltage Type B equipment This symbol indicates that waste electrical and electronic equipment must not be disposed of as unsorted municipal waste and must be collected separately. Please contact an authorized representative of the manufacturer for information concerning the decommissioning of your equipment. Name and address of manufacturer Date of manufacture Medical device catalogue number Medical device serial number Consult instructions for use Caution -orAttention, consult accompanying documents Chapter 1 Page no. 26 Definition-warning-notes.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Publication Presentation CHAPTER 2 PUBLICATION PRESENTATION 1. SCOPE AND APPLICABILITY OF THE PUBLICATION This Service publication provides all information required to understand, to plan installation, to install, and to maintain the Senographe DS. For information on associated equipment mentioned in this publication, such as the Stereo option, review workstation and CAD, refer to their specific publications. This publication contains only class A information. It is intended for use by Field Engineers installing and maintaining the system who are employed by: • GEMS. • A third party supplier with an agreed contract with GE. • A third party supplier without an agreed contract with GE. 2. CONTENT OF THIS PUBLICATION 2-1. Safety Information • The Safety chapter gives regulatory warnings which must be read and understood before reading the documentation and using the equipment. 2-2. • The Publication Presentation chapter describes the content of the publication and explains how to navigate within it. 2-3. • Publication Presentation Descriptive Chapters Descriptive chapters give information required to understand the equipment, together with reference information: - System Description gives a physical and operational description of the system. It includes, functional diagrams, FE operations, component and FRU location, and a component index. - System Identification and Follow-up gives system configuration and service history information. - Pre-Installation System Requirements specifies site planning requirements. 2-4. Procedural Chapters 2-4-1. Service Contexts • Procedural chapters describe procedures required in specific service contexts: - Pre-installation. - Physical Installation. - Electrical Installation. - Upgrade Procedures. - Corrective Maintenance. - Long Term Shutdown. - Planned Maintenance. • Installation and Planned Maintenance procedures assume that no equipment failure occurs. If an equipment failure occurs, the FE must refer to Corrective Maintenance procedures. Page no. 27 Publication Presentation.fm Chapter 2 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Publication Presentation 2-4-2. Procedural Instructions • Procedural instructions are given in three types of document: Error message lists, Scenarios, and Job Cards: 2-4-2-1 • • Error message lists document messages intended for the FE. These messages can be displayed on screen, on dedicated display panels, or stored in an error log Specified or suggested corrective actions are listed. These can include hypertext links to relevant Job Cards. 2-4-2-2 • • • • • • Scenarios A scenario is a high-level description of the steps required to carry out a defined Service action, such that: - The context is perfectly known. - The initial state and the final state are perfectly known. All the steps are identified, including preparation steps (pre-requisites) and finalization steps (post requisites). The steps are defined in Job Cards. The sequencing (order) of the steps is exactly defined. However, there can be alternative (conditional) paths in the sequence. Scenarios contain two sections: - Context: explains the circumstances in which the scenario must be performed. - Steering guide: gives the exact sequence of jobs to be performed, in a tabular format. 2-4-2-3 • Error Message Lists Job Cards Job Cards are used to describe specified independent tasks (e.g., the installation of a specific component, a calibration procedure, etc.). Job Cards include all instructions required to carry out the specified task. These can include instructions to perform other Job Cards. The same Job Card can be used in different contexts. For example, a Job Card specifying a calibration procedure can be carried out during installation, or after changing a component. Chapter 2 Page no. 28 Publication Presentation.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Publication Presentation 2-4-3. Job Card and Scenario Categories Category definition Scope JC SC code code Pre-installation Includes wall, ceiling, and floor preparation, electrical cabling, etc. PRE PRE System Physical Installation First installation on Customer site – Physical installation step = without powering-on the equipment. PHY PHY System Electrical Installation First installation on Customer site Starts with powering on the system – ends with cleaning the equipment, the room, and putting all into order. ELE ELE Upgrade Describes installation of an option or application of an FMI on an existing functional system, i.e., a change to the configuration of the system. UPG UPG Corrective maintenance: CM Configuration (HW & SW), Describes procedures for configuration of hardware and/or software. Restore procedures are considered as configuration; JCs describing backup and restore are also classified as CFG. CFG N/A Calibrations and adjustments Describes calibration and adjustment procedures. CAL N/A Tool Describes the connection and use of a measuring tool TOOL N/A Functional and performance checks Describes checks used to confirm correct global operation of the system after an installation or repair action has been performed. VF N/A REG N/A Functional and performance Equivalent to VF, but applies to a specific case of verifying checks for specific regulations compliance to one standard or regulation. Image Quality performance checks Equivalent to VF, but applies to the specific case of verifying Image Quality performance. IQ N/A Diagnostics = diagnose only Used when a problem has been identified, and it is required to locate the root cause or to choose between different root causes. May also be used to describe the use of diagnostic software tools. DIAG N/A Trouble shooting = diagnose + repair Gives general guidance for a diagnostic and repair strategy in a certain context (i.e., a certain combination of symptoms). TSG N/A Disassembly/Reassembly Describes removal and reinstallation of a component or assembly. Does not usually include calibration and verification procedures, but points to them. D/R N/A Repair Describes a repair procedure without disassembly/reassembly for an identified problem (diagnosis already done). May be used for a work-around or a “temporary fix”. REP N/A Signature Signature measurement, backup, and log book completion May call a FORM type document. SGN N/A PM PM UIST UIST Planned Maintenance Specifies planned maintenance procedures and their frequency. De-Installation Describes on-site de-installation procedures required at the end of product life. Page no. 29 Publication Presentation.fm Chapter 2 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Publication Presentation 3. PUBLICATION CONVENTIONS 3-1. Typographical Convention • • • In text describing the user interface, italic and bold characters differentiate between body text and on-screen or hardware captions and labels, entered text, etc.: - Italics are used for references to hardware items and text which appears on-screen (e.g., menu titles, button labels, on-screen messages, etc.). - Bold face is used when specific instructions are given for the entry of text or selection of a menu option, etc. In text describing the command line interface (CLI), italic and bold courier characters are used to differentiate between body text and the command line: - Italics are used for references to filenames and directory paths. - bold courier face is used when specific commands are entered at the command line. In other text: - Italics are used when a specific concept is introduced. - Italic and bold characters can also be used for local emphasis. - Blue italics are used for cross references. 3-2 Entering and Typing Instructions Depending on the situation, you are instructed to either enter or type a command or string of text. If you are instructed to enter a command or string of text, it means that you have to press the key after typing that command or string of text. For example, in a CLI you are instructed as follows: Move to the temp directory, by entering: cd temp If you are instructed to type a command or string of text, it means that you do not have to press the key after typing that command or string of text. You are instructed to type, in the following cases: - typing a menu option in a CLI which does not require you to press the key - field entries in a graphical user interface (GUI) For example, to specify your name in a GUI field you are instructed as follows: Type your first name in the First Name field. or Type 192.168.0.5 in the IP Address field. Chapter 2 Page no. 30 Publication Presentation.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Publication Presentation 4. HOW TO NAVIGATE USING ACROBAT Note: The appearance and position of the navigation buttons referred to here can vary slightly, according to your version of Adobe Reader and its configuration. 4-1. Entering the Publication • • • Open the Acrobat document. The first page of the publication (the Cover page) appears. The list of bookmarks must be displayed. If not, click the Bookmarks tab at the left of the screen. Check that the Continuous Scrolling feature is active. If necessary, click the Continuous Scrolling icon in the bottom Acrobat toolbar to highlight it: Continuous Scrolling • You can now view the publication and navigate within it. 4-2. Using Acrobat Tools to Navigate Within the Publication Adobe Acrobat Reader includes many navigation tools. Use them to access any desired part of the publication: • Change pages using the Acrobat buttons Previous page and Next page as shown in illustration 1, or using the keyboard Page up and Page down keys. • By using a “Full Text search” to locate any desired string of characters in the publication (in body text or in illustrations). In the Acrobat tool bar, select Edit/Find (or click the binocular symbol as shown in illustration 1), then type the desired string in the Find box. Click Find to locate the first occurrence, then on Find again to find more occurrences. The located string of characters is highlighted. • By clicking a section in the Table of Contents. • By clicking a topic in the list of Bookmarks as shown in illustration 2. It is important to understand the structure of the publication; this structure is represented in the Bookmark column. The folder symbol for the currently selected section is shown in gray; click another folder symbol to open the corresponding section. 4-3. Using Hypertext to Navigate Within the Publication The publication contains many programmed hypertext links, allowing you to "jump" from one location in the publication text or diagrams to view associated information, as required. Arrows in the navigation flow chart, illustration 1, indicate the types of navigation possible. • Programmed hypertext links are shown on the Acrobat screen as blue text, which indicates the location of the linked information. Click the link to display the new location. • To go back to a previously viewed page, click one of the Acrobat historic hypertext link buttons, shown in illustration 1. - Click the arrow Previous page of the publication to return to a previously selected page. - Click the arrow Next page of the publication to go forward again after returning to a previously selected page. Page no. 31 Publication Presentation.fm Chapter 2 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Publication Presentation Descriptive TOC navigation ILLUSTRATION 1 - HOW TO NAVIGATE IN THE SIP Direct access tools Table of contents Bookmarks Component Location Diagrams Product History Cable Layout and Pin-out Corrective Maintenance Procedural Troubleshooting scenario Functional Diagrams Acrobat navigation DIA or TSG Job Cards DIA Job Cards Pre-Installation scenario PRE Job Cards Electrical -Installation scenario ELE Job Cards Physical -Installation scenario PHY Job Cards Planned Maintenance scenario DR Job Card SGN Job Card CHK Job Card CAL Job Card PM Job Cards First page of the Publication Previous page of the Publication Next page of the Publication Full text search Historic ‐ To go forward after returning to a previously selected page Last page of the Publication Chapter 2 Glossary of: Tools Supplies Component Index Central Listing Error messages Favorites pages Historic ‐ To return to a previously selected page Page no. 32 Publication Presentation.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Publication Presentation ILLUSTRATION 2 - USE BOOKMARKS Page no. 33 Publication Presentation.fm Chapter 2 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Publication Presentation This page is blank. Chapter 2 Page no. 34 Publication Presentation.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Acronyms Glossary Acronyms Glossary Chapter 2 A AC ADS AET ARC ASIS AWS AW A/D Alternating Current Appollo Digital System Application Entity Title Analog Readout Chip Application Specific Integrated Circuit Acquisition Workstation Advantage Window Analog to Digital C CAN CF CL CM CPLD CPU Controller Area Network Conversion Factor Central Listing Corrective Maintenance Complex Programmable Logic Device Central Processing Unit D DC DCB DICOM DLC DMPU DMR DQE DSP DRC DPS D/R Direct Current Differential Circuit Breaker Digital Imaging and Communications in Medicine Data Length Code (CANopen protocol) Digital Mammography Processing Unit Dual Molybdenum Rhodium — A legacy term which in some cases represents a product such as Senographe DMR, and in other cases represents the Generator. Typically system error messages that include DMR in the message are actually referring to the Generator. Defective Quantum Efficiency Digital Signal Processor Digital Readout Chip Detector Power Supply Disassemble and Reassemble E EMC ESD Electromagnetic Compatibility ElectroStatic Discharge F FAU Field Adjustable Unit Page no. 35 Acronym-Glossary.fm Chapter 2 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Acronyms Glossary FD FDA FE FET FFDM FMI FOV FPGA FRU FSB FW Functional Diagram Food and Drug Administration Field Engineer Field Effect Transistor Full Field Digital Mammography Field Modification Instruction Field Of View Field Programmable Gate Array Field Replacable Unit Front System Bus Firmware or Feeder Wire G GLI Gnd Grid Line Interference Ground H HIS HNS HV HVL HT Hospital Information System Hospital Network Service OR Health Net Services High Voltage Half Value Layer High Tension I IPMS IP IIP IOD IDC I/F Isis Positioner Motion Software (old definition that covers the whole Gantry) or Interrupt Pipes Management System (low-level processor activity) Internet Protocol Insite Interactive Platform Information Object Definition Image Detection Controller Interface J JC Job Card L LFOV LMP LSL LUT LV Large Field Of View Lamp Lower Specification Limit Look Up Table Low Voltage Chapter 2 Page no. 36 Acronym-Glossary.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Acronyms Glossary M MC MCU MCM MDR MFU MQSA MTF Main Contactor Micro Controller Unit (usually refers to the HC12 chip on the Gantry nodes) MulitChip Module Main Distribution Rack Main Functional Unit Mammography Quality Standards Act Modulation Transfer Function N NPS Noise Power Spectrum O OLC OnLine Center P PB PDB PDI PDO PDU PI PPP PPS PWA PM PTB Push Button Power Distribution Board Product Delivery Instructions Process Data object (CANOpen protocol) Power Distribution Unit Part Identity Point-to-Point Protocol Performed Procedure Step Printed Wiring Assembly Planned Maintenance Positioner Tracking Board (main Gantry control board called Roadrunner that has Poseidon SW on it) Q QAP Q/R Quality Assurance Procedures OR Quality Assurance Program Query Retrieve R RF r.h. RIS RNU ROI RWS RT Radio Frequency Relative Humidity Radiology Information System Resolution Non-Uniformity Region Of Interest Review Workstation Real Time Page no. 37 Acronym-Glossary.fm Chapter 2 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Acronyms Glossary S SBC SC SCP SCU SDD SEL SID SIP SLDU SM SOP Single Board Computer Scenario Categories Service Class Provider Service Class User Source to Dosimeter Distance Select Source to Image Distance Service Information and Procedures Second Look Digital Unit Service Manual Service Object Pair T TEC TFT TP ThermoElectric Cooler Thin Film Transistor Twisted Pair U UBC USL Universal Builders Code Upper Specification Limit V VOI Volume Of Interest W WL WW Window Level Window Width Chapter 2 Page no. 38 Acronym-Glossary.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Revision History Revision History Chapter 2 Note for the Technical Writer: This publication is contained in a multibook Master folder. It is a slave publication. To maintain this publication it is mandatory to use “Master Folder” 2396423–x–8EN as the Frame Maker source. The “Master Folder” contains a “Read me” which explains how to proceed. Date Reference Main reason for change March 2012 2385072-16-8EN Rev 1 Updates for Sunburst Release August 2011 2385072-15-8EN Rev 1 Updates for Pixel Spacing Kit and IB Release June 2010 2385072-14-8EN Rev 1 Updates for LFOV2 (Nephtys M415) Page no. 39 Revision history.fm Chapter 2 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Revision History This page is blank. Chapter 2 Page no. 40 Revision history.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN System Description CHAPTER 3 SYSTEM DESCRIPTION This chapter contains descriptive information for the Senographe system. Page no. 41 Chap-System Description.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN System Description This page is blank. Chapter 3 Page no. 42 Chap-System Description.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Sub-Systems and Components Sub-Systems and Components Chapter 3 Senographe Acquisition System: Gantry Definitions: Gantry = Arm + Column + Image Receptor Arm = Tube Head + Compression Arm Image receptor = Digital Detector + Bucky or Mag Stand or Stereotactic Positioner Tube Head Compression Arm Column Generator Cabinet Conditioner Image Receptor Main Distribution Rack (MDR) Conditioner Rack Gantry readout Generator Rack Footswitches Control Station Review options: Seno Advantage Review Workstation Radiation screen X-ray Console AWS LCD monitor (b/w) AW 4.2 Processor unit LCD or CRT AW 4.2 LCD monitor (color) Diagnostic monitors Mouse or optional trackball keypad AWS keyboard (pull out from top of cabinet) AWS cabinet including: ADS computer IDC computer UPS Hub switch keyboard CAD: R2 Image Checker or SLDC CAD Processor unit CAD UPS Page no. 43 Introduction.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Sub-Systems and Components 1. SYSTEM FEATURES Senographe DS is one of the latest Digital Mammography Systems from GE Medical Systems. It has been designed to perform Screening examinations as well as Diagnostic Views (including Spot compression, Magnified and/or Coned views). It is a modular system that eliminates the need for film cassettes. It takes advantage of digital technology, including on-screen image display, Networking, Filming, and Archiving. The Senographe system is equipped with a dual track X-ray tube (molybdenum/rhodium) and a digital detector. The Digital Detector is a flat panel of amorphous silicon on which cesium iodide is deposited to maximize detection of X-rays. The X-ray Console controls the X-ray exposure parameters and controls the power to all parts of the Senographe system. The Arm control keypads control the positioning operations of the Tube Head. • It offers the capability to acquire images in near real time, process images, and manipulate images with the ability to vary brightness and contrast levels. • It also offers high examination productivity as compared with screen film, and introduces new applications such as Networking and Archiving. • It is built on a new platform, designed for superior Image Quality. The Rhodium spectrum of the X-ray tube is adapted to Digital Imaging. The Control Station includes an Acquisition Workstation (AWS) with monitor, keyboard, and mouse or trackball, computer, electronics, and Uninterruptible Power Supply (UPS). The AWS is used for image acquisition, processing, and display. The AWS can also be used for database management, and can send images to archive, review, or filming. • The Acquisition Workstation displays acquired images in the room, allowing immediate evaluation of breast positioning and possible motion blur, or adjustment of brightness and contrast. Archiving, Networking, and Filming are all possible from the Acquisition Workstation, which can produce any number of equally high quality film copies as needed. A hardcopy laser-film printer can be used for image interpretation. Printer window width and window level are set automatically, based on the image content. Images are displayed per film 1 on 1. The Acquisition Workstation can also display and print SCPT (Secondary Capture) images (if they have the modality MG). This allows the Operator to view images which have been reviewed and annotated on a review workstation (such as the Review Workstation or the SenoAdvantage). Several options are available for use with the Senographe system. These options include a review workstation, a mass archiving system, a laser camera, networking capabilities, and CD-ROM interchange media. • The optional Review Workstation is a stand-alone workstation, with its own dedicated computer and image database. It is connected to the Acquisition Workstation (AWS) by a high speed link. It supports image display and manipulation. This powerful computer is equipped with two dedicated, high resolution monochrome monitors and a dedicated keypad. Networking is possible from this workstation, as well as printing and receiving images from an archive device. Chapter 3 Page no. 44 Introduction.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Sub-Systems and Components 2. SYSTEM COMPONENT DESCRIPTION Gantry Control Station Radiation screen Generator Cabinet LCD monitor Position for mouse or optional trackball (not shown) Digital Detector X-ray Console AWS Cabinet 2-1. Overview The following pages describe the main system components: 1. The Gantry is equipped with a Digital Detector for efficient creation of X-ray images. The X-ray Console controls Gantry operations, X-ray exposures, and power to all parts of the Senographe system. The X-ray Console is normally mounted on the Control Station. 2. The Control Station includes the Acquisition Workstation (AWS) Cabinet, an LCD monitor, a keyboard and mouse (or optional trackball), and a radiation screen. The AWS Cabinet houses the workstation electronics and a UPS (Uninterruptable Power Supply). 3. Accessories (standard and optional). Mandatory marking labels such as CE marking, UL Listing labels, and FDA labels are located on the bottom left-hand side of the Generator Cabinet. Page no. 45 Introduction.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Sub-Systems and Components 2-2. Senographe X-ray System The Senographe is equipped with a dual track X-ray tube (molybdenum/rhodium) and a Digital Detector. Mammographic examinations can be made with standing, sitting, or recumbent patients; both contact and magnification views are available. Images are acquired by direct digitization; they are displayed immediately on the LCD monitor and are stored for later diagnostic review. They can be processed and/or filmed. AOP (Automatic Optimization of Parameters) and manual setting modes are provided for control of the X-ray parameters; the system provides auto-collimation. 2-3. Digital Detector and Image Receptor The Digital Detector is built into the Image Receptor, shown below. It is a flat panel of amorphous silicon on which cesium iodide is deposited to maximize detection of X-Rays and transmission of light photons. The high definition digital images produced are sent to the Acquisition Workstation for visualization and processing. A removable grid (Bucky) plugs into the Arm above the Image Receptor. For magnification views, Mag Stands providing magnifications of 1.5 or 1.8 are used instead of the Bucky. The presence of the Bucky or the Mag Stand is recognized automatically. Compression Paddle Bucky Image Receptor Chapter 3 Page no. 46 Introduction.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Sub-Systems and Components 2-4. Control Station Radiation screen LCD Monitor X-ray Console mounted on top of the cabinet Mouse or optional trackball AWS keyboard pulls out from top of cabinet Access to workstation computer and CD-R Interchange Media unit (from side of the AWS cabinet) 2-4-1. Overview The Control Station is used for image acquisition and display, database management, and to send images to archive, review or filming. It includes the Acquisition Workstation (AWS) Cabinet, which accommodates the following: • the workstation electronics (ADS computer, Image Detection Controller (IDC) computer) • the Uninterruptible Power Supply (UPS) • an integrated CD-R unit for interchange purposes The AWS Cabinet supports the LCD monitor used for control and display, a pointing device (trackball or mouse), and a radiation screen. Page no. 47 Introduction.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Sub-Systems and Components 2-4-2. Uninterruptible Power Supply (UPS) To assure system safety in the event of disturbances in the mains power supply, the Senographe system incorporates a UPS, housed in the Control Station cabinet. During power fluctuations or brief interruptions, the UPS assures a continuous supply to the workstation and the acquisition system. The UPS prevents mains disturbances from being transmitted to the system. When a power failure occurs the UPS continues to supply power to the workstation until it has shut down safely. 2-4-3. External Connections One Ethernet cable connection to the local hospital network is connected at the rear of the cabinet for external communications (such as Insite connection): Chapter 3 Page no. 48 Introduction.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Sub-Systems and Components 3. ACCESSORIES 3-1. Senographe DS Accessories • • • The Senographe DS is delivered with a standard 19 x 23 paddle for use with the Bucky. The following accessories may be standard or optional according to country: - 19 x 23 cm standard magnification paddle. - Round spot paddle. - Round spot magnification paddle. - Square spot paddle. - Square magnification paddle. - 2D large localization paddle. - 2D large spot paddle. - Phlexis paddle. - Axillary compression paddle. Paddles supplied for use with the Stereotaxy option: - Biopsy paddle for vertical approach (with aperture). - Biopsy paddle for lateral approach (no aperture). Optional accessories available for the Gantry include: - Optical localizer (consisting of cross hair and biopsy paddle) for 2D biopsy. - Examination chair. - Remote handswitch. - Bar code scanner. CAUTION Only Senographe DS recommended accessories must be used with this equipment. Failure to heed this warning can cause unexpected results and possible data loss. System Options System options available include: • Review workstation. • Mass Archiving System. When installed and connected to the Senographe system, acquired images can be sent to the mass archiving device for permanent storage, either automatically or on request. A list of all patients ever imaged on the Senographe system can be kept on the mass archiving device, making future retrievals fast and easy. • Laser Camera. To provide “hard copies” of images, the Senographe system can be connected to a high resolution DICOM MG compatible laser camera for film printing. WARNING ONLY IMAGES PRODUCED BY GE-RECOMMENDED LASER CAMERAS CAN BE USED FOR FINAL INTERPRETATION OF EXAMINATIONS. FOR COMPATIBLE PRINTERS SEE THE LATEST PRODUCT DATA SHEETS FOR THIS SYSTEM, WHICH MAY BE OBTAINED FROM YOUR LOCAL GE SALES REPRESENTATIVE. • Networking. The Senographe is DICOM compliant, allowing it to be connected in a network with Page no. 49 Introduction.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Sub-Systems and Components other compliant devices for the exchange of images. Networking allows transmission of images acquired with the Senographe system to other DICOM-compatible review workstations, using the “Network Push” function of the AWS Browser. In some cases, detailed evaluations are needed for the implementation of customized connections. DICOM conformance statements can be accessed at http://www.gehealthcare.com/usen/interoperability/dicom/index.html. • CD-R Interchange Media. For older systems an external CD-R (CD-Recordable) unit is installed in the AWS cabinet. On newer systems an internal CD-RW (CD-Rewriter) unit exists in the ADS computer. This allows selected sets of images to be saved on CD-ROMs for communication purposes (e.g., recording images for referring physicians, training, personal image library, etc.). It is not recommended for permanent archiving. See your General Electric Medical Systems Representative for more information on accessories and options. Chapter 3 Page no. 50 Introduction.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Product history and compatibility Product history and compatibility 1 • • • • • • Chapter 3 INTRODUCTION The Senographe DS Acquisition System is a product which continuously evolves to meet new needs and to take account of component improvements and obsolescence. This manual is intended to be applicable to all versions of the system. System changes are summarized in section 3 System historyOverview Chronogram of this module. This chart shows the main manufacturing versions in chronographic order. It shows the main Field Modification Instructions and hardware and software changes applicable to each manufacturing version. It indicates the corresponding Technical Releases, and the evolution of associated technical publications. The evolution and compatibility of the main electronic components are summarized in section Component FW/SW to ADS Version compatibility Matrix of this module. It indicates PI numbers used in each main version, and which components are backwards compatible. New versions may be introduced in manufacturing, or an existing system may be modified by the application of an FMI (Field Modification Instruction). Changes may also occur to individual systems when a component fails and is replaced by a newer version. Some replacement components/FRUs and some service procedures may be applicable only to certain versions of the system. The document module FRU/Component Index on page 145 identifies these components and procedures by Compatibility codes, which are described and defined in section 5 Compatibility codes on page 68 of this module. 2 MANUFACTURING VERSION IDENTIFICATION AND LABELING 2-1 How to Identify Your System As the Senographe DS system evolves, successive manufacturing versions exist for the same system name. You can identify the manufacturing version of your Senographe DS system by viewing the following two items together: • the model number on the system identification label, which can be found on the cover of the Generator Cabinet for newer systems, and on the back of the Gantry column covers for older systems. Illustration 1 on page 52 shows an example of the system identification labelling for pre-Penduick systems, and Illustration 2 on page 53 shows an example of the system identification labelling for Penduick and above systems. • the AWS Application Software version that is displayed on the Service Desktop home page. For more information on displaying the Service Desktop home page, refer to Launching the Service Desktop on page 120. Page no. 51 Product-historyDS.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Product history and compatibility 2-2 How to Identify The Model Number ILLUSTRATION 1 - LOCATION OF SYSTEM IDENTIFICATION LABEL - PRE-PENDUICK SYSTEMS Upto and including Nephtys M5A Model number for the system OR Regulatory labels From Nephtys M5B Note: Since the Gantry column covers are changed more frequently than the Generator cabinet covers, it was decided to move the identification label to the Generator cabinet covers. Some older systems which have had their Gantry column covers changed may no longer have their identification labels. Chapter 3 Page no. 52 Product-historyDS.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Product history and compatibility ILLUSTRATION 2 - LOCATION OF SYSTEM IDENTIFICATION LABEL - PENDUICK AND ABOVE SYSTEMS System Identification HV Tank ID CDRH Generator ID CDRH System Identification Label Model Number Page no. 53 Product-historyDS.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Product history and compatibility 2-3 Control Station Identification Different Control Stations can exist for the same system name. Consequently you may need to identify your type of Control Station if you are changing a particular component on the Control Station. 2-3-1 Location of Control Station Identification Label The Control Station has an identification label on its rear panel. The evolution of the different Control Stations are briefly described in the section Evolution history on page 59. 2-3-2 Differences Between V1 and V2 Control Stations The V2 Control Station differs from the V1 Control Station, as follows: • The V2 top cover contains no slot for an external CD-ROM, whereas the V1 top cover contains a slot for an external CD-ROM. • The V2 Omega covers can be removed by four screws without the need to remove the top cover. • Introduction of Ergotron B arm. As a result, the fixation of the LCD monitor is different. The arm holding the LCD monitor on the V2 now contains a bracket holder and a bracket is on the rear of the LCD monitor — this makes it far easier to install the LCD monitor. The V2 bracket holder is adjustable so you can adjust the angle of the LCD monitor. The V2 arm holding the LCD monitor now extends below to accommodate the mouse/trackball. For V1 there was a separate piece of metal connected to the back of the monitor which accommodated the mouse/trackball. • The fixation of the Radiation Shield (and the Radiation Shield) are different. On V1 the plate securing the Radiation Shield to the back cover of the Control Station was separate, whereas for V2 the plate is integrated into the back cover. • For the V2 by default there is a mouse instead of a trackball. 2-3-3 Different ADS Computers for Different Control Stations There exist different ADS Computers exist for the different versions of the Control Station, as follows. Control Station (CS) Version AWS Computer V1 CS SB150 V2 CS SB150 V3 VS U20 V4 CS Z400 2-3-4 Evolution of Rotative Arm Sets for Different Control Stations Three types of Rotative Arm Sets exist, as follows: • Ergotron A (introduced with V1 Control Stations) - contains one rotative arm support and two extension (rotative) arms. Superseded by Ergotron B arm. You cannot order the Ergotron A arm. • Ergotron B (introduced with V2 Control Stations and early V3 Control Stations) - contains one rotative arm support and two extension (rotative) arms. The Ergotron B arms are superior to the Ergotron A arms as they have more rhobust stop brackets and the LCD monitor fixation is more easily facilitated by a separate monitor bracket. • Sisfle (introduced with V3 Control Stations) - contains one rotative arm support and one extension (rotative) arm. The different Rotative Arm Sets on all Control Stations. The compatibility codes used in the Component Index for the Rotative Arm and Rotative Arm Parts are summarized below. Chapter 3 Rotative ArmCompatibility Coding Definition ErgB Applies to Ergotron B Rotative Arm only Sis Applies to Sisfle Rotative Arm only ErgB&Sis Applies to Sisfle Rotative Arm only Page no. 54 Product-historyDS.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Product history and compatibility 2-3-5 Accelera Upgraded Control Stations Some V2 Control Stations have been upgraded to V3 Control Stations, using the Accelera Upgrade Kit. Upgraded Control Stations contain FRUs specific to the Accelera upgrade (such as a VGA-DVI Adaptor, ADS-UPS Extension cable, and Ferrite Blocks), which are denoted by the compatibility code Acc. 2-3-6 Penduick V3 Control Stations A new V3 "Penduick" Control Station exists, with the following changes: • No more AC multi-socket exists on the top shelf. The Ethernet Switch and LCD Monitor are now directly connected to the UPS. As a result, the AC cables for the Ethernet Switch (5376554) and LCD Monitor (5376551) are slightly longer in length. • A new RJ-45 service connector (5158907) exists on the middle shelf for service use, which is easily accessible by simply removing the Omega Cover Side Panel rather than the entire Omega Cover. When performing certain service operations, you can now connect a laptop to the Senographe network via this new RJ-45 service connector rather than the Ethernet Switch on the top shelf. • The UPS support plate is now a different shape, such that there is no longer a panel between the UPS and IDC. • New shorter Ethernet cables (2389288-2) exist between the IDC and Ethernet Switch, and between the ADS and Ethernet Switch. An additional Ethernet cable (2389288-2) exists between the new RJ-45 service connector and Ethernet Switch. • The Ethernet switch has moved from the top shelf to the bottom right of the Control Station towards the rear of the U20 workstation. 2-3-7 V4 Control Stations A new V4 Control Station exists, based on the V3 Control Station, with the following changes: • A new HP Z400 computer exists for the ADS Computer, replacing the Sun U20. As a result: - The HP Z400 computer has a display port, so the monitor is now connected to the ADS Computer via a display port - DVI-I adaptor. - The two serial cards inserted into the Z400 computer are in the opposite order to the U20, so the serial connections on the back of the ADS Computer are in opposite positions relative to the U20. - A new mouse and keyboard exist. - The Solaris Operating System on the Z400 computer uses Xorg server instead of Xsun server for its X-Windows environment. Since Xorg auto-detects the signal from the monitor, kdmconfig is no longer required to set monitor resolution. - The network interdace cards on the Z400 computer have different device names. Therefore, the network related commands are the same as before, but use different device names for the network interface cards. • A new mouse mat, which has better performance with optical mouses. The new mouse mat is backward compatible, and must be used if you want to replace a mouse mat on an IB system. • A new Omega Cover with addition venting holes on the main side. • The RJ-45 connector for the hospital network is removed. Therefore, the hospital must be directly connected to the ADS Computer. • Lean Packaging: The threaded holes to fix the delivery wheels, located under the Control Station baseplate have moved. There are new threaded holes under located under the Control Station baseplate to accommodate C-brackets for fixing the Control Station to a pallet. The packaging of the Control Station on the pallet is now different and uses C-shaped brackets to fix the base of the Control Station to the pallet. The threaded holes under the Control Station baseplate do not impact the hole positions of the fixation holes, which are still in the same position. Page no. 55 Product-historyDS.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Product history and compatibility 2-4 AWS Application Software Versions The following table summarizes each of the different model numbers and AWS Application Software version for each manufacturing version for each manufacturing version for the Senographe DS system, and the location of the identification label. Forward Production Technical Release Manufacturing Version Model Number Model Number Label Location Control Station (CS) AWS App SW Version (*) Nephtys M3 M3 2383168 Gantry Column V1 CS Nephtys M4 M4 2383168 Gantry Column V1 CS 31.0 Nephtys M4Plus M4Plus 2383168 Gantry Column V1 CS 31.3.2 Nephtys M5A M5A 2383168-2 Gantry Column V1 CS 31.20 Nephtys M5B M5B 2383168-3 Generator Cabinet V2 CS 32.04 Nephtys M5BPlus M5BPlus Standard 2383168-3 Generator Cabinet V2 CS 32.05 M5BPlus International 2383168-3-1 Generator Cabinet V2 CS 32.05 Nephtys M5BPlus-FB M5BPlus-FB Standard 2383168-3 Generator Cabinet V2 CS 32.10 M5BPlusFB International 2383168-3-1 Generator Cabinet V2 CS 32.10 Nephtys M49 (Madras IS4-2) M49 International 2383168-4-1 Generator Cabinet V3 CS 53.00 (V3 CS) 43.00 (V1/V2 CS) Nephtys M410 (IS4-3 FMI 12075) M410 International 2383168-5 Generator Cabinet V3 CS 53.10.1 (V3 CS) 43.10.1 (V1/V2 CS) Nepthys M411 (IS4-3 Fwd Prod) M411 International 2383168-5 Generator Cabinet V3 CS 53.10.1 (V3 CS) 43.10.1 (V1/V2 CS) Nepthys M412 (Orion 1) Nepthys M412 Step 1 Nepthys M413 M412 International 2383168-6 Generator Cabinet V3 CS 53.10.10 (V3 CS) Nepthys M414 (Penduick) M414 2383168-7 Generator Cabinet V3 CS 53.40 (V3 CS) Nephtys M415 (Z400) M415 2383168-8 Generator Cabinet V4 CS 54.10 (V4 CS) Nephtys M416 (Sunburst) M416 2383168-9 Generator Cabinet V4 CS 54.20 (V4 CS) * - From Nephtys M49, two variations of the AWS Application Software are usually manufactured. One for forward production (V3 Control Stations), and another for the V1/V2 Control Station install base. Chapter 3 Page no. 56 Product-historyDS.fm GE Healthcare Senographe DS Product history and compatibility Service Information and Procedures Class A 2385072-16-8EN SYSTEM HISTORYOVERVIEW CHRONOGRAM Revision 1 3 Page no. 57 Chapter 3 This chronogram illustrates an overview of the Senographe DS evolution up to Nephtys M5BPlusFB: Product-historyDS.fm GE Healthcare Revision 1 Product history and compatibility Senographe DS Service Information and Procedures Class A 2385072-16-8EN Page no. 58 Product-historyDS.fm This chronogram presents an overview of the Senographe DS product evolution up to Nephtys M416: Chapter 3 Note: During June 2011, forward production systems had a new Type 3 Lift Screw Assembly with Motor Brake introduced in the Gantry. GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Product history and compatibility 3-1 Evolution history This section describes the Senographe DS product evolution at a high level. 3-1-1 M5BPlus Since Nepthys M5BPlus there exists the two different digital detectors with two sets different of characteristics, referred to as the Standard Digital Detector and the International Digitial Detector. These different detectors lead to the following two different Senographe DS core systems: • Senographe DS Standard (2383168-3) — manufactured with the Standard Digital Detector. • Senographe DS International (2383168-3-1) — manufactured with the International Digital Detector. If you ever need to replace the digital detector refer to Table 1 on page 1099. 3-1-2 Nephtys M5BPlus-FB • ADS Software was updated to 32.10 so that the From Below (FB) view is printed with the correct orientation. • IDC Software was updated to 4.2.5 with better functionality, and is backward compatible down to Nepthys M5BPlus. • Introduction of new Rotation, Compression, and PDU boards that contain improved firmware, which are all backward compatible as follows: - Rotation board (2375488-10) backward compatible down to Nepthys M5B - Compression board (2373563-7) backward compatible down to Nepthys M5B - PDU board (2365871-7) backward compatible down to Nepthys M4 • Introduction of version b of the Control Station V2, named Control Station V2(b). The Control Station V2(b) has slightly different hole positions for the keyboard sliders. As a result, a new FRU exists for the sliders and a slider adapter kit exists for the pre-December 2006 V2(a) Control Stations so that they can accommodate the new sliders. 3-1-3 Nephtys M49 (IS4-2 Madras) The introduction of the V3 Control Station is implemented at Nepthys M49 (IS4-2 Madras), which contains the following differences: • a new ADS Computer — The 32-bit SB150 is replaced by a 64-bit Sun U20. This new ADS Computer runs a newer "common" Service Desktop, which is very similar to the original Service Desktop. The new ADS Computer does not have a floppy disk drive. Consequently all procedures that previously used a floppy disk now use CD-R media. Some of the UNIX binaries are different, the network interface device names are different, and all the serial connections are on separate PCI boards. Consequently, some of the networking and AWS diagnostic commands are different. • a new UPS unit — The old UPS unit has been replaced by a smaller UPS unit. The new UPS unit is an APC 750 SmartUPS, and has the same connectivity and functionality as the old UPS unit. • The layout of the IDC Computer, UPS and ADS Computer is different. Consequently, in order to be able to access the DVD-ROM on the new ADS Computer the hole locations on the Omega covers are different. • there is no more Global Modem. • introduction of a new Lift Board (2373567-8) with firmware CPLD 10.0.1. The introduction of a new Bucky and the possibility to order the Bucky board as a FRU. Reduction of the number of core systems from two to one; only the Senographe DS International (2383168-4-1) exists. Page no. 59 Product-historyDS.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Product history and compatibility 3-1-4 Nephtys M410 (IS4-3 FMI 12075) • The AWS Application Software for the V3 Control Stations (U20 Workstation) was updated from V53.0 to V53.10.1. • The AWS Application Software for the V1/V2 Control Stations (SB150 Workstation) was updated from V32.10 to V43.10.1. • The Gantry CPU board was updated from NSC.1.0.10 to NSC.1.1.7. • The Interface board was updated from FPGA 2E to FPGA 4A. • FMI 12075 (DS) installed on the install base. 3-1-5 Nephtys M411 (IS4-3 Fwd Prod) • Introduction of Sisfle Rotative Arm (replaces Ergotron B Rotative Arm) on the Control Station. • The Gantry CPU board for manufacturing was updated from NSC.1.1.7 (5233827-2) to NSC.1.1.8 (5233827-3). • Introduction of V2 Clutch, which is only compatible with the Rotation Board (2375488-12). However, the Rotation Board (2375488-12) is compatible with both V1 and V2 Clutches. Note: The Rotation Board (2375488-11) is not a FRU. If you need to replace the Rotation Board (2375488-11), order Rotation Board (2375488-12). • A new Gantry Update CD-ROM (5174994-7) is delivered with the system. Note: The Gantry Update CD-ROM (5174994-7) is not a FRU. If you need to replace the Gantry CDROM, order Gantry Update CD-ROM (5174994-6). 3-1-6 Nephtys M412 (Orion 1) The support of 5 new languages and the replacement of Brazilian Portugese by continental Portugese, which results in the introduction of: • a new Generator CPU Board (2385602-9), which supports additional languages. • a new Gantry CPU Board (5233827-4), which supports additional languages. • ADS 53.10.10 on V3 Control Stations, which supports 11 languages in the user interface, and 19 languages in the embedded user documentation. • a new Lift Board (2373567-9), which supports output of additional characters to the Gantry LCD Readout. Other product enhancements, including the introduction of: • a new Paddle Holder Board (2369391-2), which has DIP switches and better reliability. The Paddle Holder Board (2369391-2) is fully backward comptible. • new Detector FRUs (2383172-4 and 2383172-5). • Type 2 Lift Screw Assembly. The Type 2 Lift Screw Assembly differs from the Type 1 Lift Screw Assembly, such that it uses a different Ball Bearing Ring, and its associated Lift Motor has an earth cable. 3-1-7 Nephtys M412 Step1 • Introduction of X-ray Console (2282675-7) and new Arm Keypads (5268425). 3-1-8 Nephtys M413 • Introduction of one Gantry board FRU strategy. • Safety compliance : New tools and filmless procedure available for Collimator checks. • Introduction of a stronger 3000 N Rotation Gas Spring (5154719). • Introduction of new Arm Keypads (5268425-2). Chapter 3 Page no. 60 Product-historyDS.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Product history and compatibility 3-1-9 Nephtys M414 (Penduick) • New and improved Gantry Boards, as follows: - Gantry CPU Board with NSC.1.2.15 (5233827-8) - Lift Board with HC12: V5.16.2 (2373567-11) - Rotation Board with HC12: V5.12.4 (2375488-13) - Compression Board with HC12: V5.12.1 (2373563-8) • New Generator CPU Board with 4.02 CMN. • New PDU board (2365871-8), with unchanged software, but contains a different F5 fuse (5344386-2) and a different transformer. This new PDU board is fully backward compatible with IB systems, and must be used to replace earlier PDU boards. • New ADS Software 53.40 (5261381-6). • New Dione 5 form factor IDC (5324091). • New IDC Software 10.0.5 (5324092) to support the Dione 5 form factor IDC. • New Strator Cable W403 (2381701-2) with corrected mA return cable connection on XP2 connector. This cable is fully backward compatible with IB systems. • New Upper Compresion Arm cover (2401145-2), which is fully backward compatible with IB systems. When changing an Upper Compression Arm cover, always order 2401145-2. • Introduction of a new V2 50 N Rotation Clutch, which is only physically compatible with the Rotation Board 2375488-12 or later. Note: Since no more V1 Rotation Clutches exist, the Spare Part Kit Clutch 2345968-4 and Rotation Board 2375488-13 (5265895-2) has been introduced for systems where both the Rotation Board and Clutch need changing, replacing Spare Part Kit Clutch 2345968-3 and Rotation Board 2375488-12 (5265895). • New Mavig Radiation Screen (5352284), which is less high and slightly thinner than the previous Lamerpax Radiation Screen. The Mavig Radiation Screen is compatible with V2, V3 and V4 Control Stations. • Introduction of a new spare part, Rotation Potentiometer and Support (2372281-2) replacing the Rotation Potentiometer spare part, which is fully backward compatible. As a result the entire Rotation Potentiometer and Support are changed. • An optional 3 MP 21" Color LCD Monitor (5370904). • A new V3 "Penduick" Control Station exists with minor modifactions from the previous V3 Control Station. See section 2-3-6, Penduick V3 Control Stations on page 55 for more information. 3-1-10 Nephtys M415 (Z400) • A new V4 Control Station exists with major modifactions compared to the V3 Control Station. See section 2-3-7, V4 Control Stations on page 55 for more information. • New ADS Software 54.10 (5261381-7) to support the new HP Z400 computer used in the V4 Control Station. Page no. 61 Product-historyDS.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Product history and compatibility 3-1-11 Nephtys M415 (Z400) - Q3/Q4 2011 During Q3 2011, the following non-software related changes were made to the system: • Forward production Gantries include a new "Type 3" Lift Screw Assembly with an integrated Motor Brake. • The FRU strategy changed for the Generator CPU Board, such that it is now delivered with no EEPROMs, and seperate EEPROM Kits are now available. For more information, see Empty Generator CPU Board and EEPROM Kits on page 66. • The System Identification Label on the Generator cover is slightly different. • Available IHE 54.11 kit for IHE sites. • New dust kit (PN: 5394527). 3-1-12 Nephtys M416 (Sunburst) - Q1 2012 • New ADS 54.20 Software (5261381-8) bringing IHE Pixel Spacing Compatibility, IPM fix and an updated UPS script Chapter 3 Page no. 62 Product-historyDS.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Product history and compatibility 4 COMPONENT FW/SW TO ADS VERSION COMPATIBILITY MATRIX The components in the Senographe system must have a certain version of firmware or software in order to work correctly at a particular system level. The following table defines the compatibility matrix between the software/firmware version required for each of these components for each system level. TABLE 1 - COMPONENT FW/SW COMPATIBILITY MATRIX System Level (Model Number) Component IS4-3 (2383168-5 and lower*) Orion1 Nephtys M412s1 Nephtys M413 Penduick (2383168-7) Z400 (2383168-8) (2383168-6) ADS Hardware Computer SB150 or U20 U20 U20 Z400 Detector Type SFOV1 or SFOV2 SFOV1 or SFOV2 SFOV1 or SFOV2 SFOV1 or SFOV2 IDC Hardware Computer Dione 4 Dione 4 Dione 5 Dione 5 ADS Software Kit 53.10.1 (U20) 43.10.1 (SB150) 53.10.10 53.40 54.10 IDC Software Kit 4.2.6 ***** 4.2.6 ***** 10.0.5 10.0.5 Generator CPU Board (DMR) 1.10 3.02 4.02 4.02 Gantry CPU Board (Poseidon) NSC.1.1.7 or NSC.1.1.8 ** NSC.1.2.5 NSC.1.2.15 NSC.1.2.15 Interface Board Rotation Board Lift Board FPGA 4A FPGA 4A FPGA 4A FPGA 4A CPLD 5.1.2 5.1.2 5.1.2 5.1.2 DSP 5.13.5 5.13.5 5.13.5 5.13.5 HC12 5.9.4 5.9.4 5.12.4 5.12.4 CPLD 5.0.1 or 10.0.1*** 10.0.1 10.0.1 10.0.1 DSP 5.6.3 5.6.3 5.6.3 5.6.3 HC12 5.10.2 5.15.2 5.16.2 5.16.2 Compression Board CPLD 5.1.4 5.1.4 5.1.4 5.1.4 HC12 5.7.1 5.7.1 5.12.1 5.12.1 Tilt Board CPLD 5.1.5 5.1.5 5.1.5 5.1.5 HC12 5.4.0 5.4.0 5.4.0 5.4.0 DSP Rev1026 Rev1026 Rev1026 Rev1026 PDU Board HC12 4.0.7 or 5.0.7 **** 5.0.7 5.0.7 5.0.7 Bucky Board CPLD 5.0.3 5.0.3 5.0.3 5.0.3 Collimator HC12 Gantry CD-ROM to use to get required system level 5.4.6 5.4.6 5.4.6 5.4.6 5174994-7 5174994-9 5174994-11 5174994-11 *- With the complete rollout of FMI12075, all systems in the field are at least at an IS4-3 system level. ** - Systems that received FMI12075 have NSC.1.1.7 and IS4-3 Forward Production systems will have NSC.1.1.8. You must use Gantry CD-ROM to ensure that the Gantry CPU Board is at NSC.1.1.8. *** - Systems that received FMI12075 may have Lift CPLD 5.0.1 and IS4-3 Forward Production systems will have Lift CPLD 10.0.1. **** - Systems that received FMI12075 may have PDU HC12 4.0.7 and IS4-3 Forward Production systems will have PDU HC12 5.0.7. ***** - IDC Software 10.0.5 introduced at Penduick must only be used on the Dione 5 form factor IDC. When changing an IDC on a pre-Penduick IB system, if no more Dione 4 IDCs exist you will receive a Dione 5 IDC on which you must install IDC SW 10.0.5. Page no. 63 Product-historyDS.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Product history and compatibility Component CESM1 (Optional Upgrade) Pixel Spacing (FMI 12166) CESM 2 (Optional Upgrade) Sunburst ADS Hardware Computer U20 or Z400 U20 or Z400 U20 or Z400 Z400 Detector Type SFOV1 or SFOV2 SFOV1 or SFOV2 SFOV1 or SFOV2 SFOV1 or SFOV2 IDC Hardware Computer Dione 5 Dione 5 Dione 5 Dione 5 ADS Software Kit 55.10 54.11 55.20 54.20 IDC Software Kit 11.10.1 10.0.5 11.10.1 10.0.5 Generator CPU Board (DMR) 5.30 4.02 5.30 4.02 Gantry CPU Board (Poseidon) NSC.1.2.15 NSC.1.2.15 NSC.1.2.15 NSC.1.2.15 Interface Board FPGA 4A FPGA 4A FPGA 4A FPGA 4A Rotation Board Lift Board Compression Board Tilt Board CPLD 5.1.2 5.1.2 5.1.2 5.1.2 DSP 5.13.5 5.13.5 5.13.5 5.13.5 HC12 5.12.4 5.12.4 5.12.4 5.12.4 CPLD 10.0.1 10.0.1 10.0.1 10.0.1 DSP 5.6.3 5.6.3 5.6.3 5.6.3 HC12 5.16.2 5.16.2 5.16.2 5.16.2 CPLD 5.1.4 5.1.4 5.1.4 5.1.4 HC12 5.12.1 5.12.1 5.12.1 5.12.1 CPLD 5.1.5 5.1.5 5.1.5 5.1.5 HC12 5.4.0 5.4.0 5.4.0 5.4.0 Collimator DSP Rev1026 Rev1026 Rev1026 Rev1026 PDU Board HC12 5.0.7 5.0.7 5.0.7 5.0.7 Bucky Board CPLD 5.0.3 5.0.3 5.0.3 5.0.3 HC12 5.4.6 5.4.6 5.4.6 5.4.6 5174994-11 5174994-11 5174994-11 5174994-11 Gantry CD-ROM to use to get required system level *- With the complete rollout of FMI12075, all systems in the field are at least at an IS4-3 system level. ** - Systems that received FMI12075 have NSC.1.1.7 and IS4-3 Forward Production systems will have NSC.1.1.8. You must use Gantry CD-ROM to ensure that the Gantry CPU Board is at NSC.1.1.8. *** - Systems that received FMI12075 may have Lift CPLD 5.0.1 and IS4-3 Forward Production systems will have Lift CPLD 10.0.1. **** - Systems that received FMI12075 may have PDU HC12 4.0.7 and IS4-3 Forward Production systems will have PDU HC12 5.0.7. ***** - IDC Software 10.0.5 introduced at Penduick must only be used on the Dione 5 form factor IDC. When changing an IDC on a pre-Penduick IB system, if no more Dione 4 IDCs exist you will receive a Dione 5 IDC on which you must install IDC SW 10.0.5. Note: This matrix is extremely important to consider when you change one of the listed components. Chapter 3 Page no. 64 Product-historyDS.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Product history and compatibility 4-1 Gantry Boards To simplify Gantry FRU management, only one version of each Gantry Board (i.e. Gantry CPU, Interface, Rotation, Lift, Compression, Tilt, Collimator, PDU, and Bucky) is available, and is based on the most common system level in the install base (currently IS4-3 Forward Production). Every time you change a Gantry Board, you must do the following: 1. Go to the Service Desktop home page (see Launching the Service Desktop on page 120). 2. Determine the system level from the ADS/IDC/Generator CPU versions displayed on the Service Desktop home page, and by consulting Table 1 on page 63. The system level will be defined by one of the System Level (Model Number) columns in Table 1 on page 63. 3. Check whether the current firmware version(s) for the new Gantry Board corresponds to the required firmware version for the that system level. • If the current firmware version(s) match the required version(s) quoted in Table 1 on page 63, no additional steps are required. • If the current firmware version(s) does not match the required version(s) you must perform a firmware update of the mismatched firmware version(s) so that the new Gantry Board firmware version(s) match those quoted in Table 1 on page 63. To update the new Gantry Board firmware follow the instructions supplied in the Gantry Software Update CD-ROM that is kept with the system. Page no. 65 Product-historyDS.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Product history and compatibility 4-2 Empty Generator CPU Board and EEPROM Kits In the past, different Generator CPU Boards (containing EEPROMs) for different system levels were available as a FRU. Now the strategy has changed, such that an empty Generator CPU Board exists (P/N 5399150), and EEPROM Kits with different part numbers exist for different system levels. To determine which EEPROM Kit you need to order, do the following: 1. Go to the Service Desktop home page (see Launching the Service Desktop on page 120). 2. Determine the system level from the ADS/IDC versions displayed on the Service Desktop home page, and by consulting Table 1 on page 63. The system level will be defined by one of the System Level (Model Number) columns in Table 1 on page 63. 3. Order the appropriate Generator CPU EEPROM Kit, according to the system level as indicated below. If the Generator CPU Board is also faulty, in addition to the EEPROM Kit, also order the empty Generator CPU board. System Level Generator (DMR) Version IS4-3 (2383168-5 and lower*) 1.10 CMN Old Generator CPU Board reference (no longer orderable) 2385602-8 Reference of EEPROMs set to be used/ordered Reference of empty Generator CPU Board to be ordered (if necessary) 5405832 (part of set of EEPROMs Kit 5405814) Orion1 Nephtys M412s1 Nephtys M413 (2383168-6) 3.02 CMN 2385602-9 5405833 (part of set of EEPROMs Kit 5405814) Penduick (2383168-7) 4.02 CMN 2385602-11 5411745 Z400 (2383168-8) 4.02 CMN 2385602-11 5411745 5399150 4.02 CMN 2385602-11 5411745 Sunburst (2383168-9) * With the complete rollout of FMI12075, all systems in the field are at least at an IS4-3 system level. Note : If the system has the CESM option, the EEPROM set will be different to those listed in this table. Refer to the CESM SIP for the CESM version EEPROM set to order. Chapter 3 Page no. 66 Product-historyDS.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Product history and compatibility 4-3 IDC and ADS Software Kit Different IDC and ADS Software kits are available as a FRU. To determine which IDC and ADS Software kits you need to order, do the following: 1. Go to the Service Desktop home page (see Launching the Service Desktop on page 120). 2. Determine the system level from the Gantry Board versions displayed on the Service Desktop home page, and by consulting Table 1 on page 63. The system level will be defined by one of the System Level (Model Number) columns in Table 1 on page 63. 3. Order the appropriate ADS or IDC Software Kit, according to the system level as follows: System Level IDC SW Kit ADS SW Kit IS4-3 (2383168-5 and lower) 4.2.6 : 2407974-4 53.10.1 (V3 CS) : 5261383-3 43.10.1 (V1/V2 CS) : 5261381-3 Orion1 Nephtys M412s1 Nephtys M413 (2383168-6) 4.2.6 : 2407974-4 53.10.10 : 5261381-4 Penduick (2383168-7) 10.0.5 : 5324092 * 53.40 : 5261381-6 Z400 (2383168-8) 10.0.5 : 5324092 54.10 : 5261381-7 Pixel Spacing 10.0.5 : 5324092 54.11: 5426229 Sunburst Level (2383168-9) 10.0.5 : 5324092 54.20: 5261381-8 * - IDC Software 10.0.5 introduced at Penduick must only be used on the Dione 5 form factor IDC. When changing an IDC on a pre-Penduick IB system, if no more Dione 4 IDCs exist you will receive a Dione 5 IDC on which you must install IDC SW 10.0.5. Note : If the system has the CESM option, the software versions will be different to those listed in this table. Refer to the CESM SIP for the CESM version software versions to order. Page no. 67 Product-historyDS.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Product history and compatibility 5 • • COMPATIBILITY CODES Because of continuous product evolution, the components and procedures used may change from time to time. New versions are not always compatible with the old, and this means that some components and procedures should be used only with certain versions of the product. This manual identifies items which are affected by such changes by codes which appear in the text or in the Compatibility column of the Component Index (see FRU/Component Index on page 145). There are two types of Compatibility Code: • Compatibility codes defined by Change Points • Compatibility code defined by a type of Subsystem 5-1 Compatibility Codes Defined by Change Points Changes introduced in manufacturing are identified by Change Points, which are described below. These points are shown in the System history chronogram. These points are used to define intervals of compatibility. The following table provide generic examples of how you should select a FRU in the Component Index. Component Compatibility code Means that FRU A -70 This FRU should be ordered for systems which technical releases have been manufactured before 70 (e.g. Nepthys M49 and below). FRU B 70-90 This FRU should be ordered for systems which technical release has been manufactured in the period 70 to 90 (e.g. Nepthys M49 to Nephtys M411). FRU C +90 This FRU should be ordered for systems which technical releases have been manufactured after 90 (e.g. Nephtys M411 and above) 5-2 Compatibility Code Defined by a Type of Subsystem Sometimes the Senographe system may be equipped with alternate subsystem. For example two types of Control station, equivalent from a feature point of view, but built with different hardware or software. The following table provide examples of how you should select a FRU related to the Control Station in the Component Index. Component Compatibility code Means that FRU A Erg This FRU should be ordered to fit into Control Stations equipped only with the Ergotron rotative arm. FRU B Sis This FRU should be ordered to fit into Control Stations equipped only with the Sisifle rotative arm. FRU C Erg&Sis This FRU should be ordered to fit into Control Stations equipped either with the Ergotron or Sisfle rotative arm. FRU D Pre-Pend This FRU should be ordered to fit into Control Stations created before Penduick. FRU E Post-Pend This FRU should be ordered to fit into Control Stations created at Penduick or above. Chapter 3 Page no. 68 Product-historyDS.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Product history and compatibility 5-3 Changes introduced in the Field In addition to changes introduced in manufacturing, some components and procedures may be affected by changes in the field. A component might be usable on a system as delivered from the factory, but not on the same system after application of a specified FMI or component replacement. 5-3-1 Uppercase Alphabetic Change Tags These changes are identified by uppercase alphabetic Field Change Tags, defined in the table below. Field Change Tag Definition Due to ADS computer change: BA M3 and M4 if ADS computer 2259357-8 replaced by 2259357-9 in field Due to collimator change: DE 5-4 Collimator with Falhauber motors replaced by Maxon in field Example of Applying Numeric Change Point Codes and Field Change Tags When changing a unit, you must be aware of both change point codes and field change codes that exist. This is because for some situations both the change point code and field change code are applicable at the same time. For example, a failure in the Control Station CD-Writer must be corrected by installing a replacement unit. The choice of replacement unit depends on the product history: - System identified by Change Point code -25; manufacturing configuration M3 or M4, The replacement unit is External CD-Writer kit reference 5142891 (replaces 2303825-2). - System identified by Change Point code 25-30; manufacturing configuration M4Plus. The replacement unit is ADS computer reference 2299357-9/10 (includes an internal CD-Writer). - System identified by Field Change code BA; manufacturing configuration M3 or M4 modified after failure of the original computer, which has been replaced by ADS computer reference 2299357-9. The replacement unit is ADS computer reference 2299357-9/10 (includes an internal CD-Writer). Page no. 69 Product-historyDS.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Product history and compatibility This page is blank. Chapter 3 Page no. 70 Product-historyDS.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Functional Diagrams Functional Diagrams 1. INTRODUCTION 1-1. Purpose of this section Chapter 3 This is a functional description of the complete system; it is split into several block diagrams with hypertext links. 1-2. How to Navigate in this section 1-2-1. From Entry Block Diagram to Others If you are viewing the document on-screen from an original Acrobat PDF file, you can use hypertext links to navigate from the Entry Block Diagram to other Block Diagrams. These links are highlighted in blue. 1-2-2. Between Twin Block Diagrams The presence of navigation buttons as shown below indicates that the same assembly has more than one point of view, and therefore requires more than one Block Diagram. They are called Twin Block Diagrams. Click one of these buttons to jump to an illustration showing another point of view of the same assembly. 1-2-3. Historical Navigation in Acrobat 1. To return to a previously selected page. 2. To go forward after returning to a previously selected page. 1 2 Page no. 71 FunctionsDS.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Functional Diagrams 2. CORRESPONDENCE BETWEEN FUNCTIONS AND COMPONENTS Functions Second Level Functions Third Level Functions Corresponding Component Found in Acquisition System Entry Block Diagram on page 74 Positioning the Patient Arm Lift Column Arm Rotation Column Stereotaxy Stereotactic Positioner Breast Compression Compression Arm Breast Compression Paddles and Mag Stand Parameter Selection and Exposure Control X-Ray Console Supplying X-Ray Tube Generator Parameter Optimization Generator Command (400 PL1) Simulating X-Ray Beam with light Collimator Positioning the Breast Generating and Controlling Exposures Irradiating the Patient X-Ray beam control Tilting the X-Ray Tube Tube Head Filtering X-Rays Filter Wheel Collimating X-Rays Collimator Antiscattering Bucky Emitting X-Rays X-Ray Tube Converting X-Rays to electric signals Image Receptor / IDC Controlling the Image Detection IDC Receiving the Image Image Correction Archiving Connectivity Printing Chapter 3 Maintain constant detector temperature Chiller Image Feedback Function (IFF) IDC Processing the Image AWS Display the Image AWS Display the Image AWS Page no. 72 FunctionsDS.fm Circuit board assembly Gantry main units Cable conduit Physical component assembly M= DC Motor Mstp Stepper motor Senographe DS Chapter 3 Functional Diagrams Electrical connection Fiber‐optic cable Water hoses Manual operation Service Information and Procedures Class A 2385072-16-8EN Page no. 73 Connector Set of components belonging to the same function Bulkhead Area GE Healthcare SYMBOLS Revision 1 3. FunctionsDS.fm Generator Conditioner Control MPCB Detector ac supply AC UPS Main Distribution Link MDR Mammo Power and Control Box X Tu -ray be Tube Head Generator HV Tank 701 X-Ray Console XJ8 Generator Command 400 PL1 XJ6 XJ7 J1 J3 Detector supply PL104 CPU Grid Sync W121 Serial Link Rx W120 Serial Link Tx W119 J8 Paddle Control Station Stereotix Detector cooling J9 Bucky Detector IDC-Detector link (fiber) AWS-Generator Link XJ6 Keyboard CD Writer Ethernet Switch CS-Gantry Link AWS-Generator Link UPS AC UPS ADS-UPS-Gene link XJ5 Main Hospital AC Supply Mains Distribution 200PL1 Supply Command 200PL2 XJ3 XJ2 Relay Board 200PL4 XJ1 Gantry a.c. supply W124 12 V dc W125 ST101 PL101 IDC-Detector link (fiber) Conditioner Control IDC-Generator link IDC-DPS link Stop Motion W216, W217 Ext. X-ray ON Lamp Ext. Power ON Lamp S205 (R) S206 (L) Note : Global Insite Modem only applicable to V1/V2 Control Stations. Service Network connection only on V3 "Penduick" and V4 Control Stations. IDC Global Insite Modem Phone Line Network Senographe DS FunctionsDS.fm Ext. RoomDoor Switch P L F ADS-IDC Link ADS-UPS-Gene link Flat panel Monitor ADS Computer XJ10 XJ7 Bulkhead area XJ2 XJ1 XJ11 1/2 : DATA 2/2 : AC POWER J10 Generator Interface 400 PL2 XJ4 Service Network Collimator Service Information and Procedures Class A 2385072-16-8EN Page no. 74 XJ9 Filter wheel Detector supplyJ2 Compression Arm 300 PL2 Anode Starter XJ2 HV cable W412 To X-ray Tube H.V.-Stator W403 GE Healthcare Conditioner Revision 1 Detector cooling ACQUISITION SYSTEM ENTRY BLOCK DIAGRAM Column Conditioner Rack Functional Diagrams 4. Chapter 3 Gantry Generator Cabinet Arm Distrib.B. W314 Column 48vdc HP F1 F2 F1/2 F2/2 W216 P' EMC filter E102 N P W108 W117 W105 W111 W217 W208 Fuse check 48vdc LP2 J1 CPU Board PL103 PL101 W101 SYS‐Bus1 J2 J8 J2 Interface Board PL104 J1 W004 GND bar J10 12 Vdc to PDU J9 Bulkhead Area EMC filter E101 N X4 P' N' Terminal Block To GND Bar ST101 To Bulkhead Cover plate Senographe DS P X3 Functional Diagrams B W002 W001 B W127 W006 N, P B1/1 B2/1 G102 GND bar G101 N', P' W123 W129 W119 W120 Chapter 3 W124 W107 DC Control Service Information and Procedures Class A 2385072-16-8EN W116 B1/2 B2/2 W125 J137 PDU Board W121 GridSync Serial link Rx Serial link Tx J138 J4 J3 J7 J5 J8 Generator J5 J6 W005 J4 W315 W106 AC PDU Supply J3 AC/DC Board PS101 W104 AC Supply Thermoswitch Page no. 75 J7 J2 AC/DC Module W114 W209 J6 J1 48vdc LP W110 48vdc LP1 W402 Tube Head AC supply Shunt R101 W109 Terminal block ST102 POS Bus 1 To XR Tube W210 F2/1 SYS POS Bus E.Stop L‐Butt. Lift + Rot. Nd. F1/1 W113 48 Vdc3 N' 48vdc1 Lift + Rot. Nd. Lift + Rot. Nd. E.Stop R‐Butt. 48 Vdc2 (‐) W112 X1 GE Healthcare W315 MPCB BLOCK DIAGRAM Arm Distrib.B. Revision 1 5. FunctionsDS.fm Comp. Arm M= W206 M201 Encoder B201 Clutch J10 J9 J8 W221 J7 Opt. fork J6 W215 J1 J7 J2 J5 J3 W211 W213 J14 M201 U201 M= J3 J13 J10 J12 Encoder Gantry Readout Lower Opt. fork S201 Upper Opt. fork J9 W203 J11 W204 J15 W202 J5 W201 J4 J1 W210 J2 W209 J3 W208 J16 W207 J17 W222 FunctionsDS.fm Foot Switches CPU Board Interface Board PL104 J7 J6 Senographe DS S202 W205 Lift Board PL201 R201 Potentiometer DS201 W206 PL101 Service Information and Procedures Class A 2385072-16-8EN S203 W219 PDU Board POS-Bus 1 48vdc-LP1 48vdc-HP Brake F2 F1 X1 W212 Page no. 76 B202 PL202 W218 Terminal block ST102 J11 Rotation Board U201 W205 W217 GE Healthcare W220 Revision 1 Potentiometer COLUMN BLOCK DIAGRAM R202 MPCB W216 Functional Diagrams 6. Chapter 3 Stop Motion Button - Right S206 Stop Motion Button - Left S205 J8 POS Bus2 W411 Tilt Board PL401 J4 Bucky Assembly W311 J3a J4a W310 J2a J10 J2a J10a W320 W301 W309 J5 J7 J8 W305 Right J1 PL305 W305 J1 Left PL305 Chapter 3 Senographe DS B303 Manual brake J3 (left and right of arm) Functional Diagrams M301 Mstp Arm Control Keypads To MPCB GND J4 M302 W001 W302 GND Bar G301 To Arm U301 Encoder J9 Mstp W313 W306 J6 Potentiometer PL303 W303 R301 . Service Information and Procedures Class A 2385072-16-8EN J2 J1 W312 B301 J5 W304a W304b Compression Board J3 PL304 W317 PL302 J2 W316 Bucky Board Paddle holder W318 J1 W408 Comp.Brake Current ON IR paddle detector W307 B302 J1 To XR Tube J2 W308 Page no. 77 W319 J1a J5 J6 Force Sensor From PL101 PDU Board J6 To Image Rec. J10 W315 48vdc-LP2 J2 J3 From PL104 Interf. Board J5 To Compr. Trolley Tilt Board PL401 W410 PL301 J9 48vdc-LP2 W314 GE Healthcare J1 Distribution Board 48vdc-LP2 W401 To Colim. PL402 SYS POS Bus J7 COMPRESSION ARM BLOCK DIAGRAM SYS Bus2 W409 To Colim. PL403 Revision 1 7. FunctionsDS.fm MPCB Tube Head J2 J8 X-Ray tube support V401 Fan S401 Zero Sensor M401 Tube Tilt 48vdc-LP2 W411 POS-Bus 2 W405 W404 Mstp J11 J12 J9 J8 PL401 J4 From Distrib. Board PL301 W413 J7 FOV Button From Distrib. Board PL301 J3 Ground cable W412 W408 Generator +HT (mA feedback) and W403 Tube stator Thermo-Switch MPCB W402 To Interface Board PL104 J4 J1a 48Vdc-LP2 Refer to Collimator Block Diagram Senographe DS FunctionsDS.fm SYS-Bus 2 Service Information and Procedures Class A 2385072-16-8EN Page no. 78 Tube HV cable J1 J10 From GND Bar G301 Tilt Board W406 X-Ray tube J2 W410 GE Healthcare W407 J1 J1 Revision 1 Left PL404 J7 TUBE HEAD BLOCK DIAGRAM W407 PL404 J1 Compression Arm Functional Diagrams 8. Chapter 3 Arm Control Keypads (left and right of tube head) Right DC/DC Board M4 S4 M3 S3 M2 S2 W506 W504 Collimator Set (Falhauber motors) W409 SYS-Bus 2 J3 W401 48Vdc-LP2 J10 W409 SYS-Bus 2 (single FRU) J9 M1 S1 CONN50 W501 J8 Interconnection Board (Falhauber) M5 W500 W504 M1 S1 W506 W504 M2 S2 W506 W504 M3 S3 W506 W504 M4 S4 Control Board PL403 Collimator with Maxon motors W502 Light Assembly DC/DC Board PL402 J4 S5 M2 S2 W504 M1 S1 W508 W504 W508 W504 M3 S3 M2 S2 W508 W504 Collimator + Control Board Set (Maxon motors) J9 M1 S1 CONN50 Interconnection Board (Maxon) W501 J8 Control Board PL403 Collimator Set (Maxon motors) Chapter 3 Functional Diagrams M4 S4 M5 M3 S3 W508 M4 S4 W500 Rectangular Blade Unit W504 S5 W505 W509 M5 J5 Collimator W508 Filter Wheel Assy. W503 Senographe DS J10 J4 Service Information and Procedures Class A 2385072-16-8EN W401 48Vdc-LP2 Rectangular Blade Unit S5 Page no. 79 J3 PL402 Collimator W506 S5 W505 W507 M5 J5 GE Healthcare Filter Wheel Assy. W503 COLLIMATOR BLOCK DIAGRAM W502 Light Assembly Revision 1 9. FunctionsDS.fm Collimator with Falhauber motors TRANSFO 2kVA Conditioner Generator J3 J1 Ground J2 AC Conditioner IEC 320C1 4/ 10 Plug Conditioner control Mains Distribution Assembly J5 Interface Board XJ11 400‐PL2 FFDM Main Distribution link J9 J8 J7 J6 AC Detector PS AC UPS J4 Operator Interface XP5 IEC 320C1 4/ 10 Plug To Detector XP4 IEC 320C1 4/ 10 Plug To UPS Senographe DS In UPS ON Detector PS ON/OFF Service Interface Line Filter 250V From IDC To Detector Water AWS Cart ON/OFF LVPS Conditioner ON/OFF FunctionsDS.fm Out Bulkhead area Service Information and Procedures Class A 2385072-16-8EN Page no. 80 MPCB GE Healthcare Mains Circuit Breaker Mains Distribution 200 PL1 Revision 1 Conditioner Rack MAIN DISTRIBUTION AND CONDITIONER BLOCK DIAGRAM Generator cabinet Power Line Filter Functional Diagrams 10. Chapter 3 Operator Main Hospital AC Supply 300 PL2 5 V, +/‐12 V Optical Fibers XJ8 XJ6 XJ7 XJ9 XJ11 XJ1 Generator XJ2 Interface 400 PL2 HV Tank XJ10 Generator Command Board XJ4 400 PL1 XJ4 XJ1 XJ1 XJ5 XJ3 Ext. Room Door Switch to/from X‐Ray Room F4 XJ3 XJ4 C1‐P C1‐M XJ6 Supply Command Board XJ10 XJ7 D27‐AK D25‐AK XJ9 F3‐2 200 PL2 T° X12 S1 T° S2 X6 TR1 XJ11 TR1 X10 X7 ‐ 1 300 PL1 23 ‐ 4 C2 ‐ HV Cable‐4 Wires + 200 PL1 C3 XJ8 XJ6 XJ9 X5 X1 XJ7 XJ4 14 4 2 A1 13 3 1 PH2 AC Supply PH1 INPUT OUTPUT Chapter 3 FUSE PHASE 2 OR NEUTRAL to Gantry Senographe DS FUSE PHASE 1 XJ3 XJ1 A2 Functional Diagrams SWITCH S1 TH1 XJ10 X3 X4 POWER LINE FILTER Emergency Stop Button Gantry XJ2 C1 ‐ to/from T° + C4 SELF L1 BR1 + Inverter Board C5 Mains Distribution Board RELAY K1 ‐ C6 ‐ + + + X9 C7 ‐ + GKA/2 ‐ + C8 X8 X‐Ray Tube Housing Return FAN C9 C10 GKA/1 mA RETURN HV Connector AUTO‐ TRANSFO Service Information and Procedures Class A 2385072-16-8EN 300 PL1 XJ1 X11 250 V AC Kv Measure XJ3 GKC PE L1 N Ext. X‐Ray On Lamp 27 V AC Page no. 81 701 PL1 AC Mains via Line Supply Cable XJ2 C2 F5 XJ2 Ext. Seno On Lamp C1 XJ11 XJ8 XJ1 Heat Sink Inverter Kv‐mA XJ1 Board To Gantry CN1 CN2 400 T1 XJ13 701 XJ2 200 PL4 0 V, + 250 V DC XJ2 XJ5 XJ7 GKB BT Power Supply XJ3 XJ6 XJ9 Relay Board GE Healthcare XJ1 0 V, + 250 Vdc GENERATOR BLOCK DIAGRAM Anode Starter XJ3 Board 0 V, + 250 Vdc To MDR XJ2 Revision 1 11. FunctionsDS.fm to Stator Motor from X‐ray Console from Gantry GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Functional Diagrams 12. CONTROL STATION BLOCK DIAGRAM 12-1. Control Station Data Distribution Diagram (CS V1/V2) MODEM serial Modem Keyboard External Ethernet RJ45 D10 UPS Trackball D9 Serial A Main A Monitor VIDEO VIDEO PCI boards External 2&1 Ethernet D4 RJ45 D6 AC D8 SCSI 2390029 AC IN CD-W SCSI OUT Note: Not present on later models with an internal CD‐W unit. 2387162 RJ45 Internal Ethernet 1 1 USB 2 2 USB HARDWARE KEY D2 AC D5 AC AC AC SB150 AC AC RJ45 OF D1 SIB 26pts SIB 50pts 3X 2X 1X ETHERNET COM1 IDC RJ45 COM2 SWITCH AC 2226612 2240227 or 2244615 2340426 2226621 2240227 or 2244615 2226625 2387162 2385966 2381694 Chapter 3 Page no. 82 FunctionsDS.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Functional Diagrams 12-2. Control Station Data Distribution Diagram (CS V3 - Pre-Penduick) External Ethernet Keyboard AC Mouse SIB 50pts SIB 26pts 2387162 AC AC AC AC AC AC IN COM2 RJ45 COM1 5177284-2 IDC AC AC UPS DVI OF HARDWARE KEY Monitor AC 2340426 3X 2X 1X ETHERNET To Generator (MDR) To Gantry RJ45 To Generator To Detector Optical Fiber Socket 2226612 USB net1 To Detector Power Supply To Conditioner 2240227 or 2244615 USB net0 To Generator U20 PCIe PCI0 PCI1 SWITCH AC 2240227 or 2244615 2226621 2226625 2387162 2385966 2381694 Page no. 83 FunctionsDS.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Functional Diagrams 12-3. Control Station Data Distribution Diagram (CS V3 - Penduick and above) External Ethernet Keyboard AC Mouse SIB 50pts 2387162 AC AC AC AC AC IN RJ45 Service Network Connection COM2 RJ45 COM1 5177284-2 IDC AC UPS DVI AC AC OF HARDWARE KEY Monitor SIB 26pts AC ETHERNET To Generator (MDR) RJ45 To Gantry 4X 3X 2X 1X To Generator 2340426 USB net1 To Detector Power Supply To Detector Optical Fiber Socket 2226612 2244615 To Generator USB net0 To Conditioner U20 PCIe PCI0 PCI1 SWITCH AC 2244615 2226621 2226625 2387162 2385966 Chapter 3 Page no. 84 FunctionsDS.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Functional Diagrams 12-4. Control Station Data Distribution Diagram (CS V4) Hospital Network HARDWARE KEY Keyboard Mouse AC 50pts SIB 2387162 Monitor AC AC AC AC AC AC RS232 RJ45 IDC 5177284-2 AC IN RJ45 Service Network Connection 26pts OF UPS DVI AC SIB COM2 USB RJ45 COM1 AC 2340426 2226625 ETHERNET 2387162 To Gantry RJ45 To Generator (MDR) 4X 3X 2X 1X DVI-I adaptor net0 1 2 To Generator To Detector Optical Fiber Socket 2244615 USB net1 To Detector Power Supply To Generator 2226612 USB To Conditioner Z400 PCIe2 PCI1 PCI0 SWITCH AC 2244615 2226621 2385966 Page no. 85 FunctionsDS.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Functional Diagrams 12-5. Control Station Power Distribution Diagram (CS V1/V2) Serial AC Module Modem AC Module Note: Not present on later models with an internal CD‐W unit. AC IN CD‐W AC AC AC AC UPS Monitor PCI Boards 2 & 1 AC AC IN SCSI 1 1 RJ45 Internal Ethernet 2 2 USB USB OUT AC AC AC AC ADS AC AC OF SIB 26Pts ETHERNET SWITCH COM1 IDC RJ45 COM2 SIB 50Pts AC 2385793 2385960 Chapter 3 Page no. 86 FunctionsDS.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Functional Diagrams 12-6. Control Station Power Distribution Diagram (CS V3 - Pre-Penduick) AC IN AC AC AC AC AC OUT AC AC AC AC AC IDC AC AC UPS Monitor AC IN AC U20 USB net0 USB net1 PCIe ETHERNET SWITCH PCI0 PCI1 AC 2385793 2385960 Chapter 3 Page no. 87 FunctionsDS.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Functional Diagrams 12-7. Control Station Power Distribution Diagram (CS V3 - Penduick and above) Monitor AC AC UPS OUT AC AC AC AC AC IDC AC AC IN AC U20 USB net0 USB net1 PCIe ETHERNET SWITCH PCI0 PCI1 AC 2385793 2385960 Chapter 3 Page no. 88 FunctionsDS.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Functional Diagrams 12-8. Control Station Power Distribution Diagram (CS V4) Monitor AC AC UPS OUT AC AC AC AC AC IDC AC AC IN AC Z400 USB USB net1 net0 1 ETHERNET SWITCH 2 PCIe2 PCI1 PCI0 AC 2385793 2385960 Chapter 3 Page no. 89 FunctionsDS.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Functional Diagrams This page is blank. Chapter 3 Page no. 90 FunctionsDS.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... Senographe Operations - How to... Chapter 3 The following pages describe how to use various Service functions of the Senographe system: • Section 1, page 93 describes the use of the X-ray Console. • Section 2, page 99 describes how to use the X-ray Console to change system parameters through the Service menu. • Information on the use of the Senographe Service Desktop, accessed from the AWS, is given in sections 5, page 120 through 12, page 139. • Section 13 describes the use of the Calculator function. Page no. 91 S2100D How To.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... This page is blank. Chapter 3 Page no. 92 S2100D How To.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... 1. HOW TO USE THE X-RAY CONSOLE 1-1. Basic Functions Console functions for the normal application are described in the Operator Manual; other operating modes are summarized below. • Access to functions. Press one of the X-ray Console function keys to select a displayed function or menu choice, which in turn can display a new set of menu selections. Continue the selection until the required function appears. • • • • Exit. To go up (back) one level in the menu structure, press the SETUP key on the X-ray Console once. Selection functions. These functions require simple selection of a menu choice from a display of options or values; confirm the choice by selecting VALID. Modification functions. These functions allow you to change the displayed value or parameter to by rotation of the X-ray Console kV knob. When the required value or parameter appears, confirm the selection by selecting VALID. Calibration functions. Some calibration functions require the Exposure button order to perform the calibration. to be pressed in WARNING Never modify a Senographe parameter value that has already been calibrated unless you have a specific reason. If you do, it is usually necessary to enter the default parameter value and completely re-calibrate the generator or Gantry for the affected parameters. 1-2. Application and Installation Modes Throughout the service documentation, reference is made to application mode and installation mode. • Application mode. The normal operating mode; the Gantry enters application mode when it is powered up, regardless of previous settings. In application mode, the six function keys below the display window carry out the functions indicated by their symbols (focal spot, track, filter, etc.). For information on using the Console in application mode, refer to the Operator Manual. • Installation mode. Provides special setup functions. To enter or leave installation mode, press the SETUP key on the X-ray Console once. Page no. 93 S2100D How To.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... In installation mode, the six function keys below the display window carry out functions or menu selections which depend on the current procedure. The choice is indicated by a label displayed above the key. The illustration below shows typical X-ray Console displays before (left) and after (right) entering installation mode. The normal key symbols (shown shaded) no longer apply, and in the example shown two of the keys (shown shaded) have no function. The remaining four carry out the functions displayed above them (e.g., the left-hand key now gives access to the GENE menus). SELECT ARM/GENE INSTALL SMALL AUTO • AUTO +0 GENE A MEDICAL LANGUAGE ARM Some special installation menus are displayed only after changing the position of the installation enable switch (see below). Chapter 3 Page no. 94 S2100D How To.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... 1-3. Console Self-Test To carry out an X-ray Console self-test you must press five keys simultaneously. Refer to the illustration below. Press and hold the two keys A, and press the three keys B. A B 1-4. Saved Parameters Checksum Parameters resulting from installation or maintenance procedures are saved in memory zones whose contents are not lost when the Gantry is switched off. To perform the saved parameter checksum function CKSUM, select SETUP/GENE/INSTAL/CKSUM/ CKSUM (from the root of the X-ray Console menu). You can now return to application mode without receiving a checksum error message. There are other menu combinations to perform a CKSUM, but they vary and depend on where you currently are in the X-ray Console menu. It is not mandatory to do a checksum each time you leave a menu. There is no risk of losing data if you switch off the Senographe displaying a checksum error. 1-5. Re-loading Default (Initial) Parameters WARNING These functions are not normally used after the Senographe system has left the factory. To re-load generator or Gantry default parameters (before any installation or calibration procedures), use the appropriate CLEAR menu. This executes a software power-up comparable to the first hardware power-up of the generator or Gantry. When the Generator CLEAR menu is used, the Senographe returns to application mode. To return to installation mode, you must change the position of the installation menu enable switch again. When the Gantry CLEAR menu is used, the Senographe returns to the Gantry installation entry level. After use of the CLEAR menu, a CHECKSUM ERROR message appears. All generator or Gantry calibration procedures must be performed, followed by a CKSUM to enable use of the new parameters. WARNING The generator CLEAR menu causes the recorded thermal condition of critical components Page no. 95 S2100D How To.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... (tube, tube housing, generator, etc.) to be reset to the cold condition. This means that an excessive temperature rise at the time that this menu is used may not be immediately detected by the software thermal protection. 1-6. Representation of Numeric Parameters When displayed on the X-ray Console, most numeric values appear in the form of real numbers in scientific notation floating point format with four significant figures, as shown in the examples below: -1.250E+3 (= -1250.00); +4.345E-1 (= 0.4345) +1.000E+0 (= 1.000) 1-7. Display of Parameter Values To display parameter values on the X-ray Console, access the calibration menu for the procedure that computes the parameter. Typically this is done at a menu choice between CALIB and PARAM. Select PARAM to display the parameter value. If the calibration procedure computes more than one parameter, turn the kV dial to display the parameters in sequence. 1-8. Modification and Entry of Values At menu points allowing entry of a measured value or modification of a parameter, there are two possible selections: NEXT and VALID. Select NEXT to allow the first character to be entered (by changing the displayed character). Select NEXT again to enter the following character, and so on. Use the kV dial to change the character being entered. Numeric or alpha-numeric characters are displayed, according to the function. Parameters are entered or modified in scientific notation form (see above). Select VALID when all characters are correctly entered. If you make a mistake, select NEXT repeatedly until you arrive at the faulty value, correct it by rotating the kV dial. To exit the modification routine, press SETUP once. Note: Pressing the VALID key is effective ONLY when the entire value, including exponent, appears. This means that if you correct a digit after making a mistake, as described above, you must press the NEXT key repeatedly until the entire parameter value is visible before you can enter the new value using the VALID key. Chapter 3 Page no. 96 S2100D How To.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... 1-9. • The DISP Parameter The DISP (display) parameter is provided to aid service procedures; it controls the display of certain parameters after an exposure. When it is set to YES, the two groups of exposure parameters shown in the table below are displayed alternately: Group 1: kV mAs mA Time Ih Group 2: Composition Thickness Prep dose Prep kV Prep track Prep filter Delta grid Composition Breast composition Thickness: Breast thickness in equivalent cm of acrylic. Prep dose: Dose for pre-shot (returned by IDC) Prep kV: kV used for pre-shot Prep track: Track used for pre-shot Prep filter: Filter used for pre-shot Delta grid: Delta time (ms) from end of X-ray emission to grid U-turn To change the DISP parameter, access SETUP/GENE/INSTAL/GENE/CONFIG/DISP, and select YES or NO. A CKSUM is NOT necessary because this parameter is not a saved parameter. When power is turned off, the value of DISP is lost and reverts to NO at the next power-up. Page no. 97 S2100D How To.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... This page is blank. Chapter 3 Page no. 98 S2100D How To.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... 2. X-RAY CONSOLE MENU TREE 2-1. Introduction This section includes flow charts illustrating use of the X-ray Console Menu Tree to access Generator and compression parameters. KEY (Values) indicates that several values can be displayed by rotating the kV knob. (Value) indicates that a single value appears or can be modified or entered. indicates that rotation of the kV knob. Either displays other parameter values, or modifies a digit or character in a string being entered. indicates that the Exposure button must be pressed in order to perform the calibration (see associated instructions for the calibration in question before using these menus). Page no. 99 S2100D How To.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... 2-2. Menu Flow Chart ILLUSTRATION 1 - A GEMS-E (gen soft version) GEN (release date) INSTAL B MAINT See Illustration 2 MEDICAL SET-UP DECOMP COMP LIFT BEEP STEREO ROTATE LIGHT HEIGHT DECOMP DEFAULT LIGHT DURATION: XX min. END OF EXPOSURE DECOMP YES NO + - VALID WITH BEEP YES DECOMPRESSION HEIGHT : xx cm + - SPEED VALID FORCE Chapter 3 ANGLE NO SPEED LIFT FOOTSWITCH SPEED ROTATION SPEED FAST FAST SLOW SLOW MAX COMPRESS FORCE daN: (value) COMPRESSION SPEED DEFAULT OBLIQUE ANGLE: XX deg. + FAST + - VALID SLOW - VALID Page no. 100 S2100D How To.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... APPLICATION MODE * These selections appear only when the password has been entered. Select arm/gene install MEDICAL VIEW PASSWORD LANGUAGE Enter your password 2 1 3 4 5 6 Select arm/gene install GENE MEDICAL LANGUAGE ARM CLINIC A ARM ACCESS VALID B Select LANGUAGE FRANC DANIS ENGL FINNI DEUTS ESPAN DUTCH NORWI ITALI PORTU SWEDI DECOMP DECOMP HEIGHT COMP FORCE Page no. 101 S2100D How To.fm LIFT BEEP ROTATE STEREO SPEED Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... ILLUSTRATION 2 - A APPLICATION MODE B CHECKSUM OF SAVED PARAM CKSUM CLEAR USING THE CLEAR FUNCTION WILL ENTAIL A COMPLETE RE-CALIBRATION OF THE GANTRY, GENERATOR AND AEC. WARNING CLEAR ALL SAVED PARAM C VALID GENERATOR CONFIGURATION TUBE PMAX MASMAX PRES. T_MAX RINIT MAX AUTHORIZED POWER POWE = (value) 3.0KW 3.5KW 4.0KW 4.5KW WARNING 5.0KW RE-INITIALIZING THE TUBE WILL ENTAIL RE-CALIBRATING THE TUBE HEATER CURRENT. USE THE FUNCTION ONLY WHEN YOU HAVE REPLACED THE X-RAY TUBE. TYPE OF TUBE 2foc/2met/1ang ANODE FOCUS MODEL MAX MAS ALLOWED mAs=(value) DCHARG NEXT VALID D TYPE OF ANODE 2Metal DM SMSA SMDA MAX EXPOSURE TIME T(s)=(value) X-RAY DISCHARGE Delay (ms) NEXT FOCUS SELECTION bifocus SINGLE NEXT VALID VALID DUAL MODEL OF TUBE : (Maxray 100TH-M1) GS412 70TH-F 70TH-D 100TH-M1 GS412 70TH-F 70TH-D 100TH-M1 VALID VALID VALID VALID SUB-SYSTEMS PRESENCE PRS-B ARM PRESENCE YES Chapter 3 NO PRS-DS PRS-IDC DIGITAL STATION PRESENCE YES NO IMAGE DETECTOR CTRL PRES. YES NO Page no. 102 S2100D How To.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... * These selections appear only when the password has been entered SETUP See Illustration 1. Select arm/gene install A GENE * MEDICAL GENE CLINIC ARM LANGUAGE GEMS-E INSTAL MAINT INSTAL PRECED (DD/MM/YY) CKSUM GENE B GENERATOR INSTALLATION CONFIG GENE AOP DOSE DISP IMAGE DATE C THIS MENU CONSISTS OF PRODUCTION TEST PROCEDURES THAT ARE OF NO USE TO THE SERVICE ENGINEER. F GENERATOR CONFIGURATION CONFIG PROD EVOLUTION Ill. 8 IMAGE INFO : YES YES NO GENERATOR CALIBRATION TUBE EXPOSURE PARAM DISPLAY YES NO HTR_SCL BIAS KV mA_meas GENERATOR EVOLUTION 300PL3 WITH THE BOARD 300PL3 YES A B Ill. 3 Ill. 4 NO AOP CALIBRATION D DATE and TIME UPDATE DAY FILM PELOTE AUTOMATIC EXPOSURE AOP DATE DD/MM/YY (values) NEXT APOLLO HOUR CELL VALID ALGO COPY TYPE F TIME HH:MN:SS (values) NEXT VALID Ill. 8 D Ill. 6 RE-INITIALISATION INIT_TUBE INIT_ENERGY C TUBE RE-INITIALISATION VALID RESET TUBE ENERGY (Reset done) VALID Page no. 103 S2100D How To.fm Ill. 5 Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... ILLUSTRATION 3 - A TUBE CALIBRATION HEATER HTR_D CTUBE CTubH WarmUp B WARNING THE TWO MENUS CTUBE AND CTUBH ARE NOT INTENDED FOR SERVICE USE. HEATER: Select Foc/Track LF/MO SF/MO LF/RH SF/RH C HEATER: LF/MO CALIB CALIB PARAM HEATER: SF/MO CALIB HEATER: LF/Rh CALIB CALIB CALIB PARAM PARAM HEATER: SF/Rh CALIB CALIB PARAM HEATER: LF/MO CALIB Same menu structure as for C_GAIN I_VALUE LF/MO Cathode Gain LF/MO GK_Ax=(3 values) CHANGE Modif LF/MO cathode gain GK_Ax=(value) NEXT Chapter 3 VALID Currents LF/MO (28 values kV/A) CHANGE Currents LF/MO modif (value) (value) NEXT VALID Page no. 104 S2100D How To.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... GENE A TUBE HTR_SCL GENERATOR CALIBRATION TUBE HTR_SCL BIAS KV mA_meas A B Ill. 4 B HTR_SCL HARDWARE CALIB TRACK1 TRACK2 Same menu structure as for TUBE WARM-UP x/y kV TRACK1 HTR_SCL HARDWARE TRACK 1 CALIB C HTR_DELTA Parameters LF/MO SF/MO PARAM HTR_SCL HARDWARE TRACK 1 LF/RH SF/RH 1st pt 2nd pt Same menu structure as for 1st pt Same menu structure as for PARAM HTR_SCL track 1 x=(2 values) calcul CHANGE THIS MENU IS ONLY ACCESSIBLE WHEN BOTH FILAMENT CURRENT VALUES HAVE BEEN MEASURED AND ENTERED VIA THE 1ST PT AND 2ND PT MENUS. PARAM HTR_SCL modif track 1 x=(value) VALID LF/MO NEXT VALID HTR_SCL CALIB TRACK1 PT1 ref=(value) CMDE CALIB THE MENU ICH_M, WHICH IS USED TO ENTER THE MEASURED FILAMENT CURRENT VALUE FOUND IN THE CALIB MENU, IS ONLY ACCESSIBLE AFTER USE OF THE CALIB MENU. Meas LF/Mo HTR_DELTA display DEL_x=(3 values) HTR_SCL TRACK1 PT1 modif ref=(value) NEXT VALID HTR_SCL TRACK1 1st point meas=(value) NEXT Page no. 105 S2100D How To.fm VALID Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... ILLUSTRATION 4 A FOCAL BIAS VOLTAGE CALIB VOLTAGE TUBE TYPE 100TH-M1 OTHERS FOCAL BIAS VOLT Display Focus/Track CHANGE 100TH-M1 BIAS CALIB PARAM OTHER BIAS CALIB CALIB PARAM IJKLMN PARAM Disp display (6 values) CHANGE IJKLMN PARAM modif display (6 values) FOCAL BIAS VOLT modif x=(2 values) VALID NEXT VALID OTHER BIAS VOLTAGE CALIB CALIB 100TH-M1 Pt: 1st 2nd 3rd 4th Pt: 1st calcul FOCAL BIAS VOLT 1st/ 2nd/ 3rd/ 4th pt CALIB FOCAL BIAS VOLTAGE modif x/y (value) NEXT VALID FOCAL BIAS VOLT display x=(2 values) CHANGE NEXT CALIB MeasV MeasV THIS MENU IS ONLY ACCESSIBLE WHEN 1ST OR 2ND OR 3RD OR 4TH PT FOCAL BIAS VOLTAGE VALUE HAS BEEN MEASURED VIA THE "CALIB" MENU. NEXT THIS MENU IS ONLY ACCESSIBLE WHEN 1ST OR 2ND PT FOCAL BIAS VOLTAGE VALUE HAS BEEN MEASURED VIA THE "CALIB" MENU. FOCAL BIAS VOLT measure meas=(value) NEXT VALID calcul FOCAL BIAS VOLT 1st/ 2nd pt CALIB FOCAL BIAS VOLT measure meas=(value) 2nd VALID Table 1: FOCAL BIAS VOLT 1st/ 2nd/ 3rd/ 4th pt ref= See Table 1 FOCAL BIAS VOLT 1st/ 2nd pt ref= See Table 1 OTHER 1st Calculated 2nd Calculated 3rd Calculated 4th 300 V 70 V 250 V N/A N/A THIS MENU IS ONLY ACCESSIBLE WHEN BOTH FOCAL BIAS VOLTAGE VALUES HAVE BEEN MEASURED AND ENTERED VIA THE ‘1ST PT’ OR ‘2ND PT’ MENUS. THIS MENU IS ONLY ACCESSIBLE WHEN BOTH FOCAL BIAS VOLTAGE VALUES HAVE BEEN MEASURED AND ENTERED VIA THE ‘1ST PT’ OR ‘2ND PT’ OR ‘3RD PT’ OR ‘4TH PT’ MENUS. FOCAL BIAS VOLT calcul VALID FOCAL BIAS VOLT calcul VALID Chapter 3 PT 100TH-M1 Page no. 106 S2100D How To.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... B GENE BIAS GENERATOR CALIBRATION TUBE HTR_SCL BIAS KV mA_meas kV mA_meas mA MEASUREMENT A CALIB PARAM Ill. 3 A mA MEASURE CALIBRATION CALIB I_MEAS CALCUL kV CALIBRATION CALIB THIS MENU IS ONLY ACCESSIBLE WHEN X-RAY TUBE CURRENT HAS BEEN MEASURED AND ENTERED VIA THE "CALIB" AND "I_MEAS" MENUS. PARAM kV PARAMETERS x=(2 values) CHANGE mA MEASUREMENT CALC VALID PARAM kV MODIF x=(value) NEXT MEASURED CURRENT meas=(value) VALID NEXT mA MEASURE CALIBRATION meas=x mA kV CALIBRATION 1st pt 2nd pt Same menu structure as for 1st pt VALID MEASUR calcul THIS MENU IS ONLY ACCESSIBLE WHEN BOTH HV VALUES HAVE BEEN MEASURED AND ENTERED VIA THE "1ST PT" AND "2ND PT" MENUS. PRESSING THE "MEASUR" KEY UPDATES THE DISPLAYED VALUE OF THE THEORETICAL MEASURED X-RAY TUBE CURRENT VALUE mA MEASUREMENT PARAM f/mA=(value) VALID CHANGE mA MEAS PARAM MODIF f/mA=(value) kV CALIB 1st point ref=(value) kV REF kV REFERENCE 1st point ref=(value) kV NEXT VALID CALIB kV_M kV CALIB 1st point NEXT NEXT VALID Page no. 107 S2100D How To.fm VALID THIS MENU IS ONLY ACCESSIBLE WHEN 1ST PT KV VALUE HAS BEEN MEASURED VIA THE "CALIB" MENU. MEASURED kV 1st meas=(value) Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... ILLUSTRATION 5 - A PM_HV/DAC CALIBRATION FREQ/HV HV/DAC PM_HV/DAC Calibration CALIB FREQUENCY/PM_HV GAIN CALIB PARAM PARAM PM_HV/DAC Calibration FREQ/PM_HV GAIN display F/HV=(value) START CHANGE FREQ/PM_HV GAIN change F/HV=(value) NEXT PM_HV/DAC PARAM display alpha=(2 values) VALID CHANGE FREQUENCY/PM_HV GAIN ref=(value) REF CALIB HV_M CALC PM_HV/DAC PARAM change alpha=(value) NEXT Send PM/HV ref START VALID FREQ/PM_HV calcul STOP VALID FREQ/PM_HV REF modif ref=(value) NEXT FREQ/PM_HV Measure meas=(value) VALID NEXT VALID default=+7.000E+2 Chapter 3 Page no. 108 S2100D How To.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... (GENE) AOP C CELL COPY AUTOMATIC EXPOSURE AOP CELL ALGO COPY TYPE default = A nSC -> E SCR PARAMETERS DUPLICATION (fsc) (screen) -> (fsc) (screen) SOURCE CELL CALIBRATION HV/DAC PM/HV TARG COPY D STER ENABLE COPY Ill. 6 A VALID SOURCE CHOICE(fsc)/(scr/nscr) SCREEN TARGET CHOICE (fsc)/(scr/nscr) FSC SCREEN PM/PM_HV calibration CALIB FSC PARAM PM/PM-HV calibration SCREEN PRESENT (yes/no) YES SCREEN PRESENT (yes/no) NO YES NO SOURCE FSC CHOICE FSC=(fsc) FSC=A PM/PM_HV PARAM display alpha=(3 values) FSC=B FSC=C CHANGE FSC=D FSC=E TARGET FSC CHOICE FSC=(fsc) FSC=A PM/PM_HV PARAM change alpha=(value) NEXT VALID FSC=C FSC=D FSC=E STEREOTIX CELL calib CALIB PARAM STEREOTIX CELL calib CELL FSC=B CALIB STEREOTIX PARAM display x=(4 values) CALC CHANGE STEREOTIX PARAM change x=(value) STEREOTIX CELL calib Cell Selection NORMAL NEXT STEREOTIX CELL calib calc LEFT CENT RIGHT VALID Page no. 109 S2100D How To.fm VALID Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... ILLUSTRATION 6 - A C Ill. 5 B AEC/AOP CALIBRATION FSC=(fsc) VALID NAME TYPE STRAT CALIB C FSC validation YES NO Select FSC Name FSC (fsc)=(name) NEXT SCREEN/FILM STRATEGY VALID MEDIUM SLOW FAST V_SLOW V_FAST S_FAST Select FSC Type 1-SCR 2-SCR N-SCR D E PM YIELD SCREEN GRID CALIB REF_ENERGY CALIBRATION mAs=(value) mAs FILM/SCREEN CALIBRATION SCREEN PRESENT YES CALIB OD_MS CALC F NO G mAs Selection mAs=(value) NEXT FSC PARAM display CALIBRATION WITH GRID YES CALIB PARAM CONFIG NO VALID PARAM REF ENERGY CALIBRATION Select Configuration Mo/Mo Mo/Al FILM/SCREEN CALIBRATION THICK CALIB CALC Mo/Rh Rh/Al Rh/Rh FSC PARAM display x=(6 values) CHANGE FILM/SCREEN PARAM change x=(value) NEXT Select plexi thickness x cm 2 cm 4 cm 6 cm VALID PARAMETERS calculation VALID Chapter 3 Page no. 110 S2100D How To.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... (GENE) ALGO D PM YIELD AUTOMATIC EXPOSURE AOP CELL ALGO COPY TYPE A REF ENERGY AEC/AOP CALIBRATION FSC=A FSC=B FSC=C FSC=D FSC=E C Ill. 5 B STATUS: (VALUE) A B C Same menu structure as FSC=A C ALGORITHM CALIBRATION FSC=(fsc) PM_yld LNRT Energ Corr E E D E Ill. 7 REFERENCE ENERGY CALI B Ill. 7 PARAM CONFIG CELL MODE SELECTION NORMAL for Stereotix 2 mode REF_ENERGY PARAM menu F G GAMMA ENR_R OD_R STEREO SCALE D_STEP Same menu structure as for OD_R REF ENERGY calculation VALID REFERENCE ENERGY display OD_x=(7 values) REFERENCE ENERGY display ENERG=(value) Measured density OD=(value) NEXT CHANGE VALID WARNING THE VALUE OF ENERG IS CALCULATED DURING THE CALIBRATION PROCEDURE AND MUST NEVER BE MODIFIED MANUALLY FOR ANY REASON WHATSOEVER REFERENCE ENERGY display GAMMA=(value) WARNING REFERENCE ENERGY change OD_x=(value) NEXT VALID REFERENCE ENERGY display OD_r=(value) CHANGE CHANGE THE VALUE OF GAMMA IS CALCULATED DURING THE CALIBRATION PROCEDURE AND MUST NEVER BE MODIFIED MANUALLY FOR ANY REASON WHATSOEVER. Page no. 111 S2100D How To.fm CHANGE REFERENCE ENERGY change OD_r=(value) NEXT VALID Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... ILLUSTRATION 7 - A TIME RECIPROCITY FAILURE fsc name HEATER REFEN LNRT PARAM B HEATER CALIBRATION CALIB PARAM CALIB REF_ENERGY OF LNRT OD_ref SCALE MAS CALIB HEATER PARAM DISPLAY Kv=(3 values) I=(value) CHANGE C HEATER PARAM MODIF Kv=(value) I=(value) NEXT VALID REF ENERGY PARAM DISPLAY OD_x=(7 values) CHANGE REF ENERGY PARAM MODIF OD_x=(value) NEXT VALID D REF ENERGY PARAM DISPLAY OD_r=(value) CHANGE REF ENERGY PARAM DISPLAY mAs=(value) CHANGE REF ENERGY PARAM MODIF OD_r=(value) NEXT VALID REF ENERGY PARAM MODIF mAs=(value) NEXT Chapter 3 VALID Page no. 112 S2100D How To.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... (GENE) ALGO E LNRT (TIME RECIP. FAIL.) ALGORITHM CALIBRATION PM_yld LNRT Energ D Corr D Ill. 6 A MAG. CORR. Ill. 6 MAGNIFICATION CORRECTION CALIB PARAM MAGNIFICATION CALIB. Config:contact/magnify B CONFIG CALIB MAGNIF. PARAM display x=(2 values) CALC LNRT PARAM display x=(3 values) CHANGE CHANGE MAGNIFICATION CALIB calc VALID LNRT PARAM change x=(value) NEXT MAGNIF. PARAM change x=(value) VALID NEXT VALID CONTACT CONFIGURATION YES NO C TIME RECIPROCITY FAILURE THICK.=x cm CALIB OD_mea MAGNIFICATION CALIB. x cm CALC THICK TIME RECIPROCITY FAILURE RECIPROCITY FAIL.:calc Select plexi thickness VALID 2 CM 4 CM CALIB MAGNIFICATION CALIB. 6 CM MEASURED OPTICAL DENSITY=(value) NEXT VALID D CALIB REF_ENERGY OF LNRT mAs=(value) CALIB CALIB REF_ENERGY OF LNRT OD_mea CALC MEASURED DENSITY OD=(value) NEXT VALID Page no. 113 S2100D How To.fm CALIB REF. ENERGY calc VALID Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... ILLUSTRATION 8 - F GENERATOR INSTALLATION CONFIG GENE AOP DOSE PROD A See Illustration 2 B AOP CALIBRATION FILM FILM (AOP) CELL ALGO COPY PELOTE APOLLO APOLLO AOP CALIBRATION TYPE OpPOINT D CALIB APOLLO AOP OPERATING PT - (VALUE) Ill. 7 LOW C MEDIUM TYPE DOSE HIGH STD CNT AOP CALIBRATION GRID/LF Ill. 5 AOP CNT TYPE value NOGRID/LF NOGRID/SF mAsPRE TAB_A AOP STD TYPE value TAB_A AOP APOLLO GRID/LF CALIB CALIB PARAM STEREO TAB_B TAB_B AOP STEREO TYPE value TAB_A TAB_B Same menu Structure as AOP DOSE TYPE value GRID/LF TAB_A TAB_B AOP CALIB WITH GRID LFMoMo LFRhRh LF MoRh NON LINEARITY mAs PRE CAL CALIB PARAM mAs PRE CORR: VAL CHANGE PADDLE PARAMETERS mAs PRE CORR: VAL NEXT 18x24 24x30 MAGN STEREO VALID 18x24 PARAM DISPLAY (2 values) CHANGE Same menu structure as 19 x 23 18 x 24 PARAM CHANGE offs = (values) NEXT Chapter 3 VALID Page no. 114 S2100D How To.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... GENE-INSTALL AOP A DOSE THIS MENU CONSISTS OF PRODUCTION TEST PROCEDURES THAT ARE OF NO USE TO THE SERVICE ENGINEER. B DOSE : Select Focus LF SF Same menu Structure as LF DOSE : Select Spectrum LF MoMo RhRh MoRh MoAl RhAl Same menu Structure as MoMo DOSE : LF Mo/Mo CALIB CALIB PARAM DOSE : LF Mo/Mo : HVL ( 2 values) DOSE : LF Mo/Mo CALIB 0 0.2 0.5 Idem Idem CALCUL CHANGE Idem DOSE : LF Mo/Mo (Name) (Value) NEXT DOSE : LF Mo/Mo 0 mm Al CALIB Meas.D WARNING VALID THE VALUES OF HVL AND TUBE YIELD ARE COMPUTED DURING THE CALIBRATION PROCEDURE AND MUST NEVER BE MODIFIED MANUALLY FOR ANY REASON WHATSOEVER. DOSE : LF Mo/Mo 0.0 mm Al (mGy) value NEXT VALID Page no. 115 S2100D How To.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... This page is blank. Chapter 3 Page no. 116 S2100D How To.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... 3. HOW TO USE THE BROWSER 3-1 Accessing the Browser To access the Browser, do the following: 1. Power on the Senographe system. A series of system initialization messages appears on the screen, then the Login: prompt appears. 2. Login as the sdc user as follows: a. At the Login: prompt enter: sdc b. At the Password: prompt, press the key. The AWS login screen like the following appears after a short delay. V3 and V4 Control Stations V1 and V2 Control Stations 3. At the AWS login screen on V1 and V2 Control Stations: • select Login from the Operation drop-down field • select clinical from the Username drop-down field • type clinical in the Password field and click the OK button. At the AWS login screen on V3 and V4 Control Stations: • type clinical in the User ID field • type clinical in the Password field and click the OK button. The Browser appears (described in Introduction on page 118). Note: The AWS login screen allows you to log in to the system with different AWS users. However, each of these AWS users belong to the same sdc UNIX user that you logged in with at the initial Login: prompt. Different AWS users exist solely so that different personnel can be tracked on the system Page no. 117 S2100D How To.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... Note: If the user waits before logging in as sdc after powering on the system, the following DMI registration failure message appears (the date and timestamp varies): unknown console login: Feb 21 13:11:00 unknown snmpXdmid: Registration with DMI failed. err = 831. To avoid the DMI registration failure message, explain customers that: • An ideal way is to remain in the room after booting the system in the mornings until they enter "sdc" at the login prompt. • They must login as sdc immediately or within 20 minutes of powering on the system. • If they fail to login within 20 minutes and are faced with the DMI registration failure message, they can simply press the key and enter sdc to login as usual. 3-2 Introduction The Browser window (known as the Browser) is displayed after someone logs in via the AWS login screen with the Login option. Hospital staff use the Browser to undertake many tasks, such as to: • Shut down the Senographe system. • Link with the HIS/RIS (Hospital/Radiology Information System). • Access the Worklist for setting up and starting patient examinations. • Select images in the workstation database for review. • Manage the database (in particular to remove images that are no longer required). • Transfer images to other workstations. • Save images on recordable CDs for data interchange. • Archive images (if the optional mass archiving system is present). It is not the scope of this document to describe fully the use of the Browser. A full description of the Browser can be found in the Senographe DS Operator Manual. There are however some routine ser- Chapter 3 Page no. 118 S2100D How To.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... vice-based functions that service personnel use, which are available from the Browser (shown below). Tools menu button QAP button Power off button Many service-based functions are accessible by clicking the Tools menu button, and then by clicking the appropriate command from the drop-down menu that appears. Clicking on the QAP button launches the Quality Assurance Procedures screen, from which you can undertake various Quality Assurance Procedures. Clicking on the Power off button powers off the Senographe System. 3-3 Restarting the Browser On some occasions (e.g. during trouble shooting), you may need to restart the Browser. Use one of the following two methods if you need to restart the Browser: • • 4. In the Browser, click the Tools menu button and then click Restart Browser in the drop-down menu. Click the title bar of the Browser window and move the Browser to expose the background. Then click the right mouse button on the background of the Browser screen, and select Restart Browser from the Root menu which appears. HOW TO USE THE COMMAND LINE The command line is required for many service-based procedures. The command line is a text-based case-sensitive tool, which allows you to execute UNIX-based shell scripts, UNIX commands, and launch X-Windows based UNIX applications. Some shell scripts and commands contain upper and lower case characters. Since the command line is Page no. 119 S2100D How To.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... case sensitive, ensure that you enter commands exactly as they a shown within the documentation. 4-1 Launching a Command Line Window To launch a command line window, click the title bar of the Browser window and move the Browser to expose the background. Then click the right mouse button on the background of the Browser screen, and from the Root menu that appears, select Service Tools then select Command window. Note: Since the Browser is launched automatically by logging in as the sdc UNIX user at the first Login: prompt, any command line window that is launched from a Browser session is automatically running as the sdc user. Most service-based procedures use the sdc user. In cases where you must log in as a different UNIX user, appropriate steps are provided to log in as that UNIX user. 5. HOW TO USE THE SERVICE DESKTOP The presentation of the Service Desktop Graphical User Interface (GUI) varies according to the version of the Control Station you are using. The Service Desktop GUI for V1 and V2 Control Stations running the SB150 Workstation uses one type of Service Desktop GUI. The V3 Control Stations running the U20 Workstation and the V4 Control Stations running the Z400 uses another type of Service Desktop GUI. These differences are highlighted briefly in the following sections, and a comparison is described in Comparison between CS V1/V2 and CS V3/V4 Service Desktop on page 142. 5-1. Introduction Most Senographe service functions are accessed through the main Control Stations monitor, by selection of menus and submenus, starting from the Service Desktop. Sections 6 through 11 describe the use of functions accessed through the Service Desktop. 5-2. Launching the Service Desktop Use one of the following two methods to access the Service Desktop. • In the Browser, click the Tools menu button then click Service Desktop in the drop-down menu. • Use the right mouse button to click in the background of the Browser screen, then select Service Tools/Service Desktop from the pop-up menu. The Service Desktop intermediate home page appears on V1 and V2 Control Stations. Illustration 9 shows the main parts of the service desktop intermediate home page for V1 and V2 Control Stations. Chapter 3 Page no. 120 S2100D How To.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... ILLUSTRATION 9 - SERVICE DESKTOP INTERMEDIATE HOME PAGE ON V1/V2 CONTROL STATIONS Navigation bar Hospital name and address Station name/ system ID Language of AWS application Version of AWS Application Current system date/time Number of remote hosts declared on the system Connectivity: IP addresses of the various subsystems System version info. for all subsystems From the Service Desktop intermediate home page, click the Submit button to access the Service Desktop home page. On V3 Control Stations, you directly arrive at the Service Desktop home page. The Service Desktop home page you can access the main functions of the Service Desktop. An icon for each available service tool appears in the Navigation bar at the top of the screen. 5-3. How to Navigate in the Service Desktop Illustration 10 and 11 show how to access the main service functions from the service desktop. Available functions ar represented by icons in the navigation bar. In the following sections, screens for each service function are illustrated and the main capabilities are summarized. Page no. 121 S2100D How To.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... ILLUSTRATION 10 - NAVIGATING IN THE SERVICE DESKTOP Error Log Diagnostics Image Quality Calibration Configuration Utilities (section 6) (section 7) (section 8) (section 9) (section 10) (section 11) Home Chapter 3 Exit Page no. 122 S2100D How To.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... ILLUSTRATION 11 - NAVIGATING IN THE SERVICE DESKTOP ON V3/V4 CONTROL STATIONS Error Log Diagnostics Image Quality Calibration Configuration Utilities Replacement PM (section 6) (section 7) (section 8) (section 9) (section 10) (section 11) (not available) (not available) Home Exit Page no. 123 S2100D How To.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... The table below summarizes the functions of the Service Desktop navigation buttons. The buttons on the left correspond to the V1/V2 Control Station and the buttons on the right correspond to the V3/V4 Control Station. Button Description of Service Desktop toolbar Opens the system error log pages, which contain error logs for the Generator, AWS, and IDC. See How to Use the Error Log on page 125. Opens the diagnostic pages. See How to Use Diagnostics on page 127. Opens the Image Quality (IQ) pages. See How to Use the Image Quality Function on page 129. Opens the Calibration pages. See How to Use Calibration Functions on page 131. Opens the Site configuration pages. See How to Use the Configuration Function on page 135. Opens the Utilities pages, which include a set of tools used for backup, restore, launch telnet, etc. See How to Use the Utilities Function on page 137. Returns to the Service Desktop Home Page. Chapter 3 Page no. 124 S2100D How To.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... 6. HOW TO USE THE ERROR LOG Click the Error Log button in the Service Desktop navigation bar to view details of all errors logged by the Senographe system. To limit the number of errors displayed, type the desired number in the box, then click the Partial View check box. By default, errors are listed by date in descending order. To filter errors which satisfy a condition, type the condition in the corresponding box, then click the Filter check box. Click an error code for an explanation of the error. (not applicable for Gantry errors; see Note below). Note: Gantry errors are saved in a format which is slightly different from that of IDC and AWS errors. Clicking on Gantry errors does not display an explanation. ILLUSTRATION 12 - ERROR LOG ON V1/V2 CONTROL STATIONS Page no. 125 S2100D How To.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... ILLUSTRATION 13 - ERROR LOG ON V3/V4 CONTROL STATIONS Note: The error logs on V3/V4 Control Stations are listed in reverse order to the error logs on the V1/V2 Control Stations. Chapter 3 Page no. 126 S2100D How To.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... 7. HOW TO USE DIAGNOSTICS Click the Diagnostics button in the Service Desktop navigation bar to launch diagnostic tests for the different subsystems and communication links of the Senographe system. Specific instructions are given for each diagnostic test, and results are displayed at the end of each test. ! Notice: After running diagnostics, always reboot the system before handing it back to the customer, to ensure correct configuration. This is especially important after tests which require disconnection of communications links. ILLUSTRATION 14 - DIAGNOSTICS ON V1/V2 CONTROL STATIONS Page no. 127 S2100D How To.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... ILLUSTRATION 15 - DIAGNOSTICS ON V3/V4 CONTROL STATIONS Note: If you select the UPS diagnostics option on the V3/V4 Control Station an APS Login page appears. The login credentials to access the APS UPS Diagnostics are: - username: root - password: root Chapter 3 Page no. 128 S2100D How To.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... 8. HOW TO USE THE IMAGE QUALITY FUNCTION Click the Image Quality button in the Service Desktop navigation bar to: • View results of image quality tests performed in the past. • Launch a new image quality diagnostic test. To view the results of a past test, click the desired line under Result History, then click the Select button. To launch a new image quality diagnostic test, click the New Acquisition button. Results are displayed in the Image Quality Test Results column. ILLUSTRATION 16 - IMAGE QUALITY ON V1/V2 CONTROL STATIONS Page no. 129 S2100D How To.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... ILLUSTRATION 17 - IMAGE QUALITY ON V3/V4 CONTROL STATIONS Chapter 3 Page no. 130 S2100D How To.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... 9. HOW TO USE CALIBRATION FUNCTIONS Click the Calibration button in the Service Desktop navigation bar for access to calibration functions. Available calibration procedures are summarized below in sections 9-1 through 9-8. ILLUSTRATION 18 - CALIBRATION ON V1/V2 CONTROL STATIONS Page no. 131 S2100D How To.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... ILLUSTRATION 19 - CALIBRATION ON V3/V4 CONTROL STATIONS Chapter 3 Page no. 132 S2100D How To.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... 9-1. Calibration of Detector 9-1-1. Bad Pixel Calibration The bad pixel calibration identifies all detector cells which have a response curve different from that of other cells subject to the same dose, even after flat field correction. Bad pixel calibration is a process which uses a number of acquisitions to identify such cells and store their positions in a bad pixel map. The bad pixel correction process, applied to acquired images, uses the map to replace the level read from each bad pixel with the mean level of neighboring cells. Refer to Job Card CAL A041 - Bad Pixel Calibration on page 1693. 9-1-2. Gain Calibration The detector gain calibration compensates for differences in pixel response and differences in electronic gain. This calibration ensures that the image of a flat uniform object looks flat and uniform (flat field uniformity). Refer to Job Card CAL A043 - Detector Gain Calibration on page 1697. 9-1-3. Conversion Factor Measurement The conversion factor (CF) measurement determines the relationship between the X-ray dose received and the brightness of the corrected image. The conversion factor is used for automatic optimization of parameters (AOP) calculations. Refer to Job Card CAL A045 - Conversion Factor Measurement on page 1701. 9-2. Calibration of AWS Monitor The AWS monitor calibration adjusts the AWS monitor settings for brightness, contrast, horizontal and vertical width, and linearity. 9-3. Calibration of Tube Tilt The tube tilt calibration determines the X-ray tube angle when in its reference position. This calibration is done by taking an exposure with the field coverage depth limited by the anode geometry (and not by the rear collimator blade), measuring this field coverage depth, and entering this depth into the Gantry, which can then calculate the X-ray tube angle when in its reference position. Refer to Job Card CAL A027 - Tube Tilt Calibration on page 1681. 9-4. Calibration of Collimator Format The collimator format calibration determines the exact magnification of the collimator blades. This allows determination of the correct collimator blade positions in order to produce the different fields of view (small, medium, and large). Refer to Job Card CAL A029 - Collimator Format Calibration on page 1683. 9-5. Calibration of Lift Travel Limits The lift travel limits calibration sets the lift lower and upper travel limits in software, defining the minimum, and maximum usable heights. Refer to Job Card ELE A010 - Set Lift Travel Limits on page 565. Page no. 133 S2100D How To.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... 9-6. Calibration of Rotation The arm rotation calibration sets travel limits in software, defining the maximum positive and negative usable angles. Refer to Job Card CAL A021 - Arm Rotation Calibration on page 1679. 9-7. Calibration of Compression Force The compression force sensor is factory calibrated. However, if parts have been replaced or disturbed which affect the software or hardware settings, calibration must be carried out. Refer to Job Card CAL A048 - Calibration of Compression Force Sensor on page 1709. 9-8. Compression Thickness Calibration The breast thickness calibration calibrates the absolute breast thickness measurement read by a linear potentiometer linked to the compression carriage. This is done by defining two points in the range of travel of the compression carriage. Refer to Job Card CAL A050 - Compression Thickness Calibration on page 1721. Chapter 3 Page no. 134 S2100D How To.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... 10. HOW TO USE THE CONFIGURATION FUNCTION Click the Configuration button in the Service Desktop navigation bar for access to configuration functions. These allow you to change certain basic system parameters, such as language, date and time, or site details. Refer to Job Card ELE A013 - AWS Configuration on page 573. ILLUSTRATION 20 - CONFIGURATION ON V1/V2 CONTROL STATIONS Page no. 135 S2100D How To.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... ILLUSTRATION 21 - CONFIGURATION ON V3/V4 CONTROL STATIONS Chapter 3 Page no. 136 S2100D How To.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... 11. HOW TO USE THE UTILITIES FUNCTION Click the Utilities button in the Service Desktop navigation bar for access to utilities functions allowing you to: • Backup and restore system information • Install the software onto subsystems • Format a floppy disk on V1/V2 Control Stations and CD Erase on V3/V4 Control Stations • • • • • Note: You must only use the CD Erase function with CD-RW media and not with CD-R media. Eject CD-ROM on V3/V4 Control Stations Open a telnet session (on V1/V2 Control Stations only) Upgrade the detector manufacturing data after detector replacement Install Gantry software patches (first SW Install) Install Detector software patches (second SW Install or Detector FW Install) ILLUSTRATION 22 - UTILITIES ON V1/V2 CONTROL STATIONS Page no. 137 S2100D How To.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... ILLUSTRATION 23 - UTILITIES ON V3 CONTROL STATIONS UP TO ADS 53.10.10 ILLUSTRATION 24 - UTILITIES ON V3 CONTROL STATIONS GREATER THAN ADS 53.10.10 AND V4 CONTROL STATIONS Chapter 3 Page no. 138 S2100D How To.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... 12. HOW TO VIEW THE STATUS PANEL To access the Status Panel to view the status of workstation components, do the following: • For V1/V2/V3 Control Stations, press down the meta (♦) key and the F1 key at the same time. • For V4 Control Stations, press down the Windows (á) key and the F1 key at the same time. Alternatively, you can do the following: 1. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). 2. In the command window that appears, start the ADS Command Panel by entering: cmdpanel The ADS Command Panel window appears. Page no. 139 S2100D How To.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... 3. Click Panel and select Meta F1 System Status from the drop-down menu to display system status information in the ads Room Control Panel: 4. To close the Room Control Panel, click the Cancel button. 5. When you have finished using the ads Command Panel, click the minimize button at the top right corner; the window remains active. To view it again, press the Front key on V1/V2/V3 Control Stations or the Alt + Tab keys together on V4 Control Stations to bring the minimized window to the front, and double-click it. Chapter 3 Page no. 140 S2100D How To.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... Note: If you close the panel by using the option in the Config drop-down menu, the system application closes and must restart it. Page no. 141 S2100D How To.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... 13. HOW TO USE THE CALCULATOR The Calculator function is frequently useful, and is required for some calibration operations. • To access the calculator, right-click the Browser screen background and select Calculator from the drop-down menu. A calculator like the following appears. 14. COMPARISON BETWEEN CS V1/V2 AND CS V3/V4 SERVICE DESKTOP The presentation of the Service Desktop Graphical User Interface (GUI) varies according to the version of the Control Station you are using. The Service Desktop GUI for V1 and V2 Control Stations running the SB150 Workstation uses one type of Service Desktop GUI. The V3 Control Stations running the U20 Workstation and the V4 Control Stations running the Z400 Workstation uses another type of Service Desktop GUI. As seen briefly in the sections above, both types of Service Desktop GUI have a common layout, such that: • All the main service functions are accessible from icons horizontally display along the top. The buttons differ slightly but in general look the same. • When a particular service function is selected, its associated commands appear vertically down the left-hand side. For V1 and V2 Control Stations these commands appear as buttons under headings. For V3 and V4 Control Stations these commands appear as collapsible/expandable menu items of those headings. Chapter 3 Page no. 142 S2100D How To.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... • The main area to the right of the commands section contains content appropriate to the service function or service function command that was selected. This content is functionally the same between the two different Service Desktops, however it can differ slightly in its presentation. To reduce repetition in this document, and because of a lot of similarity exists between the two Service Desktop GUIs, the following documentation conventions are used: • The procedures are written generically, but the Service Desktop GUI screens are shown only for the V1/V2 Control Stations (and not the V3/V4 Control Stations). • The access to service function commands is written generically in the format "Click Service Action Command under Some Heading". For V1/V2 Control Stations, you actually click a Service Action button under Some Heading. For V3/V4 Control Stations, you actually click Some Heading to expand its contents and then click the Service Action listed under that heading. In the example below, the procedural text would be written "Click AWS-IDC under Communications". Some Heading (e.g. Communications) Some Service Action Command (e.g. AWS-IDC) Page no. 143 S2100D How To.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Senographe Operations - How to... This page is blank. Chapter 3 Page no. 144 S2100D How To.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN FRU/Component Index FRU/Component Index 1 Chapter 3 OVERVIEW Components listed in the Component index are units which have significance for the Field Engineer (FE). They can be physically seen or touched, or are described in the service documentation. A component is not necessarily a FRU (Field Replaceable Unit). Components are listed in three Component Index tables which follow this module, one for each main sub-assembly (refer to Main sub-assemblies on page 148). 2 COMPONENT INDEX TABLE ENTRIES Each Component Index table contains component information in 11 columns. The contents of each column are described in the following sections: 2-1 Class This column gives a numeric code which identifies the class of the component. Within each sub-assembly, components are sorted by class. The following table gives class codes and definitions, with examples of components within each class. Class Class title 15 Electronic components 25 Electronic sub-assemblies 35 Electrical components 45 Electrical sub assemblies 55 Examples Capacitor Coil Encoder Fuse (on-board, low power) Display LED Optical fork (detector) Potentiometer Switch Resistor (on-board, low power) Circuit Board Computer Digital detector EMC filter Equipped rack Keyboard LCD Non-equipped rack Power supply User Interface Mouse/Trackball X-ray tube Battery Circuit Breaker Connector Fuse (high power) Lamp Resistor (high power) Switch Terminal block Transformer Cable Handswitch HV unit Footswitch Electromechanical components Brake Clutch Fan Force sensor Motor Pump 65 Electromechanical sub-assemblies Filter wheel Tilt Assembly X-ray collimator Bucky 75 Mechanical component Accessories (for Operator use) Bearing Belt Cable tie Covers Curtain Gear Screw Transportation wheel Washer Page no. 145 Component-index-intro.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN FRU/Component Index Class Class title 85 Mechanical sub-assemblies 95 Hydraulic components 105 Optical component Lens 115 Chemical product Coolant liquid Fixing product Processing product 125 Labeling Label Publication 135 Software Software backup kit 2-2 Examples Paddle Hydraulic jack Gas Spring Component Description The description is made up as follows: Component name in the form: Type of component-Function. Where appropriate, an identification code or that of an additional attached component follows the component name. For example: - Board-Compression PL303 - Potentiometer-Lift + W203 There are four possible types of component (the types are not mutually exclusive). Type Field Replaceable Unit FRU or renewal part Field Adjustable Unit Unit containing components that provide information to the FE (e.g., a status indicator light), or can be adjusted (e.g., switches, jumpers, or potentiometers) Main Functional Unit Unit mentioned in a Functional Block Diagram (not including cables). Examples are: - Boards - Main electromechanical components (e.g., motor, brake, pump) - Displays Cable 2-3 Definition Cables linking sub-assemblies or assemblies Reference This is the ePDM reference of the component or sub-assembly. It is always given if the component is a FRU; this number is used for ordering. If the component is not a FRU, the reference is normally not given. However, the reference can be given in some cases when it is considered useful as an aid to identification. Some components have two references. In this case, they are called Alternates, and the FE can order either component. The words Alt A or Alt B at the end of the component description identify alternate components. 2-4 Comp. (Compatibility) An entry in this column indicates that the component must be used only on certain versions of the equipment. This column may contain two types of information; a compatibility code which helps you decide which FRU to order, and/or cross cross reference to the Product History chapter which describes the product evolution. The codes used to define compatibility are described and defined in the Compatibility codes on page 68. Chapter 3 Page no. 146 Component-index-intro.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN FRU/Component Index 2-5 Loc (Location) An entry in this column means that the component is mentioned in a diagram or illustration contained in the FRU/Component Location on page 185. A link is provided to the diagram or illustration. 2-6 FD (Functional Diagram) An entry in this column means that the component is mentioned in a diagram contained in the Functional Diagrams on page 71. A link is provided to the diagram. 2-7 Cabl (Cable Information) An entry in this column means that the component is described in the Cable Lay-out and Pin-out on page 299. A link is provided to the description. 2-8 CL (Central Listing) An entry in this column means that the component is described in the Central Listing on page 239. A link is provided to the description. 2-9 FRU (Field Replaceable Unit) The entry in this column indicates whether the component is a FRU: • FRU Y: It is a FRU, and can be ordered. • FRU N: It is not a FRU. 2-10 Trac (Traceability) The entry in this column indicates FRU Traceability: • Trac Y: the FRU is tracked by a product locator. • Trac N: the FRU is not tracked by a product locator. 2-11 D/R (Disassembly/Reassembly) • • • • • An entry of D/R in this column indicates that Disassembly/Reassembly of the component is explained in a D/R Job Card. The D/R Job Card includes any required post-requisite procedures (recalibrations and checks, etc.). A link is provided to the appropriate D/R Job Card. An entry of P-D/R in this column means that Disassembly/Reassembly of the component does not require specific explanation (no D/R Job Card is provided). However, some recalibrations and/or checks are required after changing or disturbing the component. These requirements are listed in the Post-D/R scenario (Scenario PDR A001 - Post-D/R Procedures on page 821). A link is provided to the appropriate section. If the D/R column is blank, the Disassembly/Reassembly of the component is considered self-explanatory, and that no special recalibration or check is needed after replacement. If the D/R column is contains SWF, this means that Disassembly/Reassembly instruction of the component is Supplied With the FRU. When a component is not a FRU (i.e. FRU N), the D/R indicated corresponds to the FRU (i.e. FRU Y) that contains the non-FRU. Page no. 147 Component-index-intro.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN FRU/Component Index 3 COMPONENT INDEX TABLE SORT ORDER The component index tables list components in order, according to main sub-assembly, class, and alpha-numeric component description. 3-1 • • • Main sub-assemblies The Senographe DS consists of three main sub-assemblies: - Control Station - Gantry - Generator Each component forms part of one of these main sub-assemblies, and the component index includes three tables, one for each sub-assembly. Cables connecting two sub-assemblies are allocated to one sub-assembly or another as shown. Except for the X-ray Console cable, no cables pass directly between the Control Station and the Generator Cabinet. Control Station Gantry Allocated to Control Station 3-2 Generator Allocated to Gantry Component Class Within each sub-assembly, components are sorted according to their class code (see Class on page 145). 3-3 Component Description Within each class, components are sorted by component description, in alphanumeric order. Chapter 3 Page no. 148 Component-index-intro.fm Component Description Reference Comp. Loc FD Cabl CL FRU Trac D/R FRU Y 25 ADS Computer SB150 (for V1/V2 Control Stations) 5189602 CS V1/V2 page 54 Loc page 202 FD page 82 FRU Y Trac N D/R page 1401 25 ADS Computer SUN U20 250Gb 1Gb (for V3 Control Stations) 5189387 CS V3 page 54 Loc page 204 FD page 84 FRU Y Trac N D/R page 1401 25 ADS Computer HP Z400 250Gb 1Gb (for V4 Control Stations) 5390674 CS V4 page 66 Loc page 206 FD page 85 FRU Y Trac N D/R page 1401 25 IDC Computer (Dione 4 form factor) 2375961 See Supplies on page 1503 PrePenduick Loc page 203 FD page 82 FRU Y Trac N D/R page 1503 25 IDC Computer (Dione 5 form factor) 5324091 See Supplies on page 1503 Penduick and above Loc page 203 FD page 82 FRU Y Trac N D/R page 1503 25 Console-X-Ray 2282675-7 Loc page 201 FD page 74 FRU Y Trac N 25 Handswitch and Cable 36005901-3 Loc page 207 FRU Y Trac N 25 Handswitch (no Cable) 46-270800G5 Loc page 207 FRU Y Trac N 25 Ethernet Switch 2382605 Loc page 202 FRU Y Trac N 25 LCD-AWS Monitor 18" or 19" or 3 MP 21" See Supplies on page 1469 See page 1469 Loc page 201 FD page 82 FRU Y Trac N D/R page 1469 25 BNC T-Adaptor (for AWS Monitor) (for V1/V2 Control Stations) 5165566 CS V1/V2 page 54 Loc page 201 FD page 82 FRU Y Trac N P-D/R page 822 Senographe DS 2407693 FRU/Component Index - Control Station Chapter 3 Bar Code Reader Service Information and Procedures Class A 2385072-16-8EN Page no. 149 25 GE Healthcare Class Chapter 3 Revision 1 Component-index.fm FRU/Component Index - Control Station Comp. Loc FD FD page 82 Cabl CL FRU Trac D/R FRU Y Trac N P-D/R page 822 5166327 CS V1/V2 page 54 Loc page 201 25 Keyboard type 6 UNIX and Mouse for SB150 (for V1/V2 Control Stations) 2404717 CS V1/V2 page 54 Loc page 201 FRU Y D/R page 1417 25 U20 Keyboard (for V3 Control Stations) 5233716 CS V3 page 54 Loc page 201 FRU Y D/R page 1417 25 Keyboard type 7 UNIX and Mouse for U20 (for V3 Control Stations) See supplies on page 1443 CS V3 page 54 Loc page 201 FRU Y D/R page 1417 and page 1443 25 XS Complete Keyboard (for V4 Control Stations) See supplies on page 1443 CSV4 page 54 Loc page 201 FRU Y D/R page 1443 25 XS Complete Mouse (for V4 Control Stations) 5394733 CSV4 page 54 Loc page 201 FRU Y D/R page 1417 25 Global Modem Kit (for V1/V2 Control Stations) 2245794 CS V1/V2 page 54 Loc page 203 25 ADS Trackball kit 5161412 25 UPS (for CS V1/V2) 2375014 CS V1/V2 page 54 Loc page 202 25 UPS (for CS V3/V4) 5195664 CS V3/V4 page 54 35 Battery for UPS (for CS V1/V2) 2295553 CS V1/V2 page 54 FRU Y Trac N FRU Y Trac N D/R page 1427 FD page 74 FRU Y Trac N D/R page 1521 Loc page 204 FD page 74 FRU Y Trac N D/R page 1521 Loc page 202 FD page 74 FRU Y Trac N D/R page 1529 FD page 82 Loc page 201 Senographe DS Component-index.fm 75 Ohm BNC Terminator for AWS Monitor (for V1/V2 Control Stations) Service Information and Procedures Class A 2385072-16-8EN Page no. 150 25 GE Healthcare Reference Revision 1 Component Description FRU/Component Index - Control Station Chapter 3 Class Reference Comp. Loc FD Cabl CL FRU Trac D/R 5193471 CS V3/V4 page 54 Loc page 202 FD page 74 FRU Y Trac N D/R page 1529 35 Battery for AWS (U20) motherboard (for CS V3) 5334112 CS V3 page 54 Loc page 202 FD page 74 FRU Y Trac N D/R page 1537 35 Connector-Wall (2 x optical fiber) 2231528 FRU Y Trac N 35 SB-150 CD-ROM drive 5392254 FRU Y Trac N 45 Cable-AWS Line 1 2226625 FRU Y Trac N 45 Cable-Control Station Pos Harness 5142875 FRU Y Trac N 45 Cable-Ethernet 2385966 FD page 74 Cabl page 322 FRU Y Trac N 45 Cable-Gene-ADS/UPS 2387162 FD page 82 Cabl page 322 FRU Y Trac N 45 Cable-Ground 2385960 FD page 86 45 Cable-IDC Conditioner Control 2226612 45 Cable-IDC Gantry serial link Alt A 45 45 CS V1/V2 page 54 FD page 82 Loc page 200 Cabl page 322 D/R page 1457 FRU N Cabl page 322 FRU Y Trac N 2240227 FD page 82 Cabl page 322 FRU Y Trac N Cable-IDC Gantry serial link Alt B 2244615 FD page 82 Cabl page 322 FRU Y Trac N Cable Console Generator (L=12,5 m) 5142876 FRU Y Senographe DS FD page 82 FRU/Component Index - Control Station Chapter 3 Battery for UPS (for CS V3/V4) Service Information and Procedures Class A 2385072-16-8EN Page no. 151 35 GE Healthcare Component Description Revision 1 Component-index.fm Class Comp. Loc FD Cabl CL FRU Trac 2226613 FD page 82 Cabl page 322 FRU Y Trac N 45 Cable-IDC Optical fiber port 2340426 FD page 82 Cabl page 322 FRU Y Trac N 45 Cable-IDC SIB or Gitane 26 pin 2226621 FD page 82 Cabl page 322 FRU Y Trac N 45 Cable-Kit-Carthage (for V1 Control Stations) 2389287 CS V1 page 54 FRU Y 45 Cable-Kit-Carthage (For V2/V3 Control Stations) 5145683 CS V2/V3 page 54 FRU Y 45 Cable-Kit-Carthage (For V3 Control Stations) 5388869 CS V3 page 54 45 Internal Cable Set incl Ethernet cable, etc... (for V4 Control Stations) 5388869-2 CS V4 page 54 45 Cable-Monitor VGA BNC (for CS V1/V2 or a V3 Control Station upgraded via Accelera Kit) 2390029 CS V1/V2 page 54 45 AWS DVI Monitor Cable (for V3 Control Stations) 5177284-2 CS V3 page 54 45 Cable-SCSI VHDCI 68-HD50 (not required with computer-ADS SB150 2299357-9 or later) 2402214 CS V1 page 54 45 Cable-UPS Power supply 2385793 45 VGA-DVI Adaptor 5364339 Acc page 55 FRU Y Trac N 45 ADS-UPS Extension cable 5214756 Acc page 55 FRU Y Trac N 45 Ferrite Block 2X1/2CYL+ENV Z275/100M D6 2109168 Acc page 55 FRU Y Trac N FRU Y FD page 82 FRU Y FRU Y FD page 86 FRU N Senographe DS Component-index.fm Cable-IDC Generator Serial link Service Information and Procedures Class A 2385072-16-8EN Page no. 152 45 D/R GE Healthcare Reference Revision 1 Component Description FRU/Component Index - Control Station Chapter 3 Class Reference Comp. Acc page 55 Loc FD Cabl CL FRU Trac D/R FRU Y Trac N FRU Y Trac N Loc page 204 FRU Y Trac N Loc page 201 FRU N Trac N D/R page 503 45 RJ-11/RJ-45 Hospital Network Patch Panel 2226632 45 RJ-45 Service Network Patch Panel 5158907 75 Cover-Omega 75 Cover-Top (without opening) for Control Stations without External CD-Writer 2391899-4 CS V1/V2 page 54 Loc page 203 FRU Y Trac N D/R page 503 75 Cover-Top (with opening) for Control Stations with External CD-Writer 2391899-2 CS V1 page 54 Loc page 203 FRU Y Trac N D/R page 503 75 Radiation Screen (for V1 Control Stations) 2409301 CS V1 page 54 Loc page 201 FRU Y Trac N 75 Lamerpax Radiation Screen (for V2/V3/V4 Control Stations) (for China) 5170447 CS V2/ V3/V4 page 54 Loc page 201 FRU Y Trac N D/R page 1463 75 Mavig Radiation Screen (for V2/ V3/V4 Control Stations) (not China) 5352284 CS V2/ V3/V4 page 54 Loc page 201 FRU Y Trac N D/R page 1463 75 Radiation Screen Pinch Assembly (for V1 Control Stations) 2408435 CS V1 page 54 75 Ergotron B Rotative Arm Set (replaces Ergotron A Rotative Arm Set) 5168412 ErgB page 54 Loc page 208 FRU Y Trac Y D/R page 1483 45 Left Stop Bracket Set for Ergotron Rotative Arm (delivered in the Accessories box) 5166732 ErgB page 54 Loc page 208 FRU N Trac N Inst. page 415 75 Monitor and Mouse Support Kit 5168123 ErgB page 54 Loc page 208 FRU Y Trac N PostPend page 68 Senographe DS 2107112 FRU/Component Index - Control Station Chapter 3 Ferrite Block 2X1/2CYL+ENV Z250/100M D13 Service Information and Procedures Class A 2385072-16-8EN Page no. 153 45 GE Healthcare Component Description Revision 1 Component-index.fm Class Comp. Loc ErgB&Sis page 54 FD Cabl CL FRU Trac Loc page 209 FRU Y Trac N Loc page 209 FRU Y Trac N D/R 5137577 75 Mouse Mat (for all Control Stations 5392259 75 Mouse Mat Support 5212331 ErgB&Sis page 54 Loc page 209 FRU Y Trac N 75 Monitor Fixation 5166557 ErgB&Sis page 54 Loc page 209 FRU Y Trac N 75 Sisfle Rotative Arm Set 5224479 Sis page 54 Loc page 209 FRU Y Trac N D/R page 1483 75 Stop Bracket Set for Sisfle Rotative Arm 5244791 Sis page 54 Loc page 209 FRU Y Trac N Inst. page 415 75 30 mm Monitor Cable Harness 5156705 Sis page 54 Loc page 209 FRU Y Trac N 75 Silicone Masks for Sisfle Rotative Arm 5270827 Sis page 54 Loc page 209 FRU Y Trac N 75 Stop Screw for Sisfle Rotative Arm 5233539 Sis page 54 Loc page 209 FRU Y Trac N 75 Keyboard slider rails (pair of) 5138587 FRU Y Trac N 75 Keyboard slider adapter kit for pre-December 2006 V2a Control Station 5214757 FRU Y Trac N 75 Bucky Support 5162608 75 Mounting Hardware Kit 5168526 -60 page 54 FRU Y CS V2/V3 page 54 FRU Y SWF Senographe DS Component-index.fm Arm Handle (for both Ergotron and Sisfle Rotative Arms) Service Information and Procedures Class A 2385072-16-8EN Page no. 154 75 GE Healthcare Reference Revision 1 Component Description FRU/Component Index - Control Station Chapter 3 Class Reference Comp. Loc FD Cabl CL FRU Trac D/R See page 67 Loc page 202 FRU Y P-D/R page 822 135 Software Backup kit-ADS V53.10.1 for U20 (Control Station V3) 5261381-3 See page 67 Loc page 204 FRU Y P-D/R page 822 135 Software Backup kit-ADS V53.10.10 for U20 (Control Station V3) 5261381-4 See page 67 Loc page 204 FRU Y P-D/R page 822 135 Software Backup kit-ADS V53.40 for U20 (Control Station V3) 5261381-6 See page 67 Loc page 204 FRU Y P-D/R page 822 135 Software Backup kit-ADS V54.10 for Z400 (V4 Control Stations) 5261381-7 See page 67 Loc page 206 FRU Y P-D/R page 821 135 Software Backup kit-ADS V54.20 for Z400 (V4 Control Stations) 5261381-8 See page 67 Loc page 206 FRU Y P-D/R page 821 135 Software Backup set-IDC V4.2.6 2407974-4 See page 67 Loc page 203 FRU Y P-D/R page 822 135 Software Backup set IDC V10.0.5 (for Dione 5 form factor) 5324092 See page 67 Loc page 203 FRU Y P-D/R page 822 135 Gantry Update CD-ROM for Nephtys M410 (IS-43) 5174994-7 See page 63 FRU Y 135 Gantry Update CD-ROM for Nephtys M412, M412s1 and M413 (Orion 1) 5174994-9 See page 63 FRU Y 135 Gantry Update CD-ROM for Nephtys M414 (Penduick) 5174994-11 See page 63 FRU Y Chapter 3 Senographe DS 5261383-3 FRU/Component Index - Control Station Software Backup kit-ADS V43.10.1 (For V1/V2 Control Stations) Service Information and Procedures Class A 2385072-16-8EN Page no. 155 135 GE Healthcare Component Description Revision 1 Component-index.fm Class Reference Comp. Loc FD Cabl CL FRU Trac D/R 99184799 FRU Y 15 Emergency kit-Fuse 6.25A 99184453 FRU Y 15 Fuse, 250 Vac, 6.25 A, Delay (F1 on PDU Board) 46-170021P60 Loc page 290 CL page 290 FRU Y 15 Fuse, 250 Vac, 0.5A, Delay (F3 on PDU Board) 46-170021P31 Loc page 290 CL page 290 FRU Y Trac N D/R page 1109 15 Fuse, 250 Vac, 2A, Delay (F4 on PDU Board) 46-170021P30 Loc page 290 CL page 290 FRU Y Trac N D/R page 1109 15 Fuse, 250 Vac, 125 mA, Delay (F5 and F6 on PDU Board) 5344386-2 Loc page 290 CL page 290 FRU Y Trac N D/R page 1109 15 Fuse, 60 Vac, 0.3 A, Resettable (F1 on Compression Board, and F1 on Tilt Board) 5314541-5 Loc page 288 FRU N Trac N D/R page 1109 15 Fuse, 60 Vac, 0.3 A, Resettable (F2/F3 on Compression Board, and F2/F3 on Tilt Board) 2214421 Loc page 288 FRU N Trac N D/R page 1109 15 Optical Fork-Lift-Lower 2345940 Loc page 192 FD page 76 FRU Y Trac N D/R page 1171 15 Optical Fork-Lift-Upper 2345937 Loc page 192 FD page 76 FRU Y Trac N D/R page 1167 15 Optical Fork-Rotation 2345966 Loc page 191 FD page 76 FRU Y Trac N D/R page 1231 15 Potentiometer-Compression + W303 2345909-2 Loc page 194 FD page 77 FRU Y Trac N D/R page 1289 D/R page 1109 Senographe DS Component-index.fm Emergency kit-Fuse 0.125A Service Information and Procedures Class A 2385072-16-8EN Page no. 156 15 GE Healthcare Component Description Revision 1 Class Chapter 3 FRU/Component Index - Gantry Chapter 3 FRU/Component Index - Gantry Reference Comp. Loc FD Cabl CL FRU Trac D/R Loc page 192 FD page 76 FRU Y Trac N D/R page 1175 15 Rotation Potentiometer and Support 2372281-2 Loc page 191 FD page 76 FRU Y Trac N D/R page 1239 15 Motor Pulley 2369419 Loc page 194 FD page 77 FRU Y Trac N 25 Board-AC/DC Module PS101 2343283 Loc page 199 FD page 75 FRU Y Trac N D/R page 1147 25 Board-Arm Distribution PL301 5128963 Loc page 193 FD page 77 FRU Y Trac N D/R page 1143 25 Board-Bucky PL302 5214502 Loc page 193 FD page 77 CL page 294 FRU Y 25 Board-Collimator Control PL403 2324334-3 Loc page 195 FD page 78 CL page 295 FRU N Trac N D/R page 1369 25 Board-Collimator DC-DC PL402 2376691 Loc page 195 FD page 78 CL page 296 FRU Y Trac N D/R page 1379 25 Board-Collimator Interconnection (Falhauber) 2376693 -30 page 68 Loc page 195 FD page 78 FRU N Trac N D/R page 1369 25 Board-Collimator Interconnection (Maxon) 2408939 DE or +20 page 68 Loc page 195 FD page 78 FRU N Trac N D/R page 1369 25 Board-Compression PL303 2373563-8 See page 67 Loc page 194 FD page 77 FRU Y Trac N D/R page 1323 CL page 288 DR page 1347 Senographe DS 2345944-2 FRU/Component Index - Gantry Chapter 3 Potentiometer-Lift + W203 Service Information and Procedures Class A 2385072-16-8EN Page no. 157 15 GE Healthcare Component Description Revision 1 Component-index.fm Class Comp. Loc FD Cabl CL FRU Trac D/R FRU Y Trac N D/R page 1131 5233827-8 See page 67 Loc page 196 FD page 75 25 Board-Interface PL104 2386985-2 See page 67 Loc page 196 FD page 75 CL page 293 FRU Y Trac N D/R page 1125 25 Board-Lift DC PL201 2373567-11 See page 67 Loc page 192 FD page 76 CL page 286 FRU Y Trac N D/R page 1161 25 Board-Paddle Holder PL304 2369391 See Supplies on page 1331 See page 1331 Loc page 193 FD page 77 FRU Y Trac N D/R page 1331 25 Board-Paddle Holder PL304 2369391-2 See Supplies on page 1331 See page 1331 Loc page 193 FD page 77 FRU Y Trac N D/R page 1331 25 Board-PDU PL101 2365871-8 Loc page 197 FD page 75 CL page 290 FRU Y Trac N D/R page 1137 25 Board-Rotation PL202 2375488-13 Loc page 191 FD page 76 CL page 286 FRU Y Trac N D/R page 1223 25 Board-Tilt PL401 2375399-5 Loc page 195 FD page 78 CL page 288 FRU Y Trac N D/R page 1365 25 Bucky Assembly Package. Replaces 2389883-X and 5128239. The package contains Bucky (PN 2389883-X). 5128239-2 Loc page 193 FD page 77 FRU Y Trac N D/R page 1339 25 Converter-AC/DC Module 48VDC 2316486-3 Loc page 199 FD page 75 FRU Y Trac N D/R page 1153 25 Digital Detector-Image Receptor See Table 1 on page 1099 Loc page 193 FD page 77 FRU Y Trac N D/R page 1099 25 Display-Stereotix-Remote FRU Y Trac N 2389787 See page 67 Senographe DS Component-index.fm Gantry CPU Board (PL103) Service Information and Procedures Class A 2385072-16-8EN Page no. 158 25 GE Healthcare Reference Revision 1 Component Description FRU/Component Index - Gantry Chapter 3 Class Reference Comp. Loc FD Cabl CL FRU Trac D/R Trac N D/R page 1215 Loc page 199 FD page 75 FRU N 25 Filter-EMC E102 Loc page 198 FD page 75 FRU N 25 Gantry Readout-Column DS201 2387891 Loc page 188 FD page 76 FRU Y 25 Power Supply-Detector 2292162-2 Loc page 200 FD page 74 FRU Y 25 Tube-X-Ray 100TH-M1 2281990 Loc page 195 FD page 78 FRU Y Trac N 35 Breaker-Circuit C10A MPCB 2387401 Loc page 199 FD page 75 CL page 297 FRU Y Trac N 35 Fuse, 600 Vac, 20 A, Fast (F1/F2 on MPCB in Gantry) 2387747 Loc page 297 FD page 75 CL page 297 FRU Y Trac N 35 Terminal Block-ST101 Loc page 199 FD page 75 FRU N 35 Terminal Block-ST102 Loc page 198 FD page 75 FRU N 45 Button-Stop Motion Left 2345917 Loc page 197 FD page 76 45 Button-Stop Motion Right 2345916 45 Cable-AWS Generator Serial link 2226623 CL page 297 D/R page 1107 Trac N FD page 76 FRU Y Trac N FD page 74 FRU Y Trac N D/R page 1109 Senographe DS FRU Y D/R page 1353 FRU/Component Index - Gantry Chapter 3 Filter-EMC E101 Service Information and Procedures Class A 2385072-16-8EN Page no. 159 25 GE Healthcare Component Description Revision 1 Component-index.fm Class Comp. Loc FD Cabl CL FRU Trac 2386021 FD page 74 FRU N Trac N 45 Cable-Detector System Fiber 2385694 FD page 74 FRU Y Trac N 45 Cable-Gaine BLC BL 2151138 FRU Y Trac N 45 Cable-Gantry Conditioner Control 2226611 FD page 74 FRU Y Trac N 45 Cable-Nephtys Detector to power supply 2386549 FD page 74 FRU Y Trac N 45 Cable-Nephtys system coolant hose 2387073 FD page 74 FRU Y Trac N 45 Cable-UPS ac supply 2225470 FD page 74 FRU N Trac N 45 CAN Bus Kit, containing the following BUS cables: 5173047 FRU Y Trac N FRU Y Trac N Loc page 200 • W314 - Sys Positioner (2345920-2) • W208 - Positioner (2345953) • W213 - Positioner Between Nodes (2345960) • W311 - Positioner for Bucky (2372186) • W308 - Positioner for Compression (2372181) • W411 - Positioner for Tilt (2345919) • W409 - System for Collimator (2345934) • W101 - System (2345976) Component-index.fm 45 Cable-W001 2346015 Loc page 199 FD page 75 Cabl page 299 Senographe DS Cable-Detector ac supply Service Information and Procedures Class A 2385072-16-8EN Page no. 160 45 D/R GE Healthcare Reference Revision 1 Component Description FRU/Component Index - Gantry Chapter 3 Class Reference Comp. Loc FD Cabl CL FRU FD page 75 Cabl page 299 FRU N 45 Cable-W004 Loc page 199 FD page 75 Cabl page 299 FRU N 45 Cable-W005 Loc page 199 FD page 75 Cabl page 299 FRU N 45 Cable-W006 Loc page 199 FD page 75 Cabl page 299 FRU N 45 Cable-W101 Loc page 196 FD page 75 Cabl page 299 FRU N 45 Cable-W104 Loc page 197 FD page 75 Cabl page 300 FRU N 45 Cable-W105 Loc page 198 FD page 75 Cabl page 300 FRU N 45 Cable-W106 Loc page 199 FD page 75 Cabl page 300 FRU N 45 Cable-W107 Loc page 199 FD page 75 Cabl page 300 FRU N 45 Cable-W108 Loc page 198 FD page 75 Cabl page 301 FRU N 45 Cable-W109 Loc page 198 FD page 75 Cabl page 301 FRU N 45 Cable-W110 Loc page 198 FD page 75 Cabl page 301 FRU N Senographe DS Loc page 199 FRU/Component Index - Gantry Chapter 3 Cable-W002 D/R Service Information and Procedures Class A 2385072-16-8EN Page no. 161 45 Trac GE Healthcare Component Description Revision 1 Component-index.fm Class Comp. Loc FD Cabl CL FRU Trac Loc page 198 FD page 75 Cabl page 301 FRU N 45 Cable-W112 Loc page 198 FD page 75 Cabl page 301 FRU N 45 Cable-W113 Loc page 198 FD page 75 Cabl page 301 FRU Y Trac N 45 Cable-W114 FD page 75 Cabl page 302 FRU Y Trac N 45 Cable-W116 Loc page 196 FD page 75 Cabl page 302 FRU N 45 Cable-W117 Loc page 198 FD page 75 Cabl page 302 FRU N 45 Cable-W119 TX 2381704 FD page 75 Cabl page 302 FRU Y Trac N 45 Cable-W120 RX 2381702 FD page 75 Cabl page 303 FRU Y Trac N 45 Cable-W121 GridSync 2381706 FD page 75 Cabl page 303 FRU Y Trac N 45 Cable-W123 FD page 75 Cabl page 303 FRU N 45 Cable-W124 FD page 75 Cabl page 303 FRU N 45 Cable-W125 FD page 75 Cabl page 303 FRU Y 2345987 2381710 Trac N Senographe DS Component-index.fm Cable-W111 Service Information and Procedures Class A 2385072-16-8EN Page no. 162 45 D/R GE Healthcare Reference Revision 1 Component Description FRU/Component Index - Gantry Chapter 3 Class Reference Comp. Loc FD Cabl CL FRU Loc page 199 FD page 75 Cabl page 304 FRU N Cable-W129 FD page 75 Cabl page 304 FRU N 45 Cable-W201 FD page 76 Cabl page 304 FRU N 45 Cable-W202 FD page 76 Cabl page 304 FRU N 45 Cable-W203 FD page 76 Cabl page 304 FRU N 45 Cable-W204 FD page 76 Cabl page 304 FRU N 45 Cable-W205 FD page 76 Cabl page 305 FRU N 45 Cable-W206 FD page 76 Cabl page 305 FRU N 45 Cable-W207 FD page 76 Cabl page 305 FRU N 45 Cable-W208 Loc page 196 FD page 76 Cabl page 305 FRU N 45 Cable-W209 Loc page 197 FD page 76 Cabl page 306 FRU N 45 Cable-W210 FD page 76 Cabl page 306 FRU N Senographe DS 45 FRU/Component Index - Gantry Chapter 3 Cable-W127 D/R Service Information and Procedures Class A 2385072-16-8EN Page no. 163 45 Trac GE Healthcare Component Description Revision 1 Component-index.fm Class Comp. Loc FD Cabl CL FRU Trac 2345958 FD page 76 Cabl page 306 FRU Y Trac N 45 Cable-W212 2345959 FD page 76 Cabl page 306 FRU Y Trac N 45 Cable-W213 2345960 FD page 76 Cabl page 307 FRU Y Trac N 45 Cable-W215 FD page 76 Cabl page 307 FRU N 45 Cable-W216 FD page 76 Cabl page 307 FRU N 45 Cable-W217 FD page 76 Cabl page 307 FRU N 45 Cable-W218 FD page 76 Cabl page 307 FRU N 45 Cable-W219 FD page 76 Cabl page 308 FRU N 45 Cable-W220 FD page 76 Cabl page 308 FRU N 45 Cable-W221 FD page 76 Cabl page 307 FRU N 45 Cable-W222 FD page 76 Cabl page 305 FRU N 45 Cable-W301/W302 FD page 77 Cabl page 308 FRU Y 2345907 Senographe DS Component-index.fm Cable-W211 Service Information and Procedures Class A 2385072-16-8EN Page no. 164 45 D/R GE Healthcare Reference Revision 1 Component Description FRU/Component Index - Gantry Chapter 3 Class Reference Comp. Loc FD Cabl CL FRU FD page 77 Cabl page 309 FRU N Trac D/R Cable-W304A 2345910 FD page 77 Cabl page 309 FRU Y Trac N 45 Cable-W304B 2379180 FD page 77 Cabl page 309 FRU Y Trac N D/R page 1319 45 Cable-W305 2345911 FD page 77 Cabl page 310 FRU Y Trac N D/R page 1217 45 Cable-W306 FD page 77 Cabl page 310 FRU N 45 Cable-W307 FD page 77 Cabl page 310 FRU N 45 Cable-W308 FD page 77 Cabl page 311 FRU N 45 Cable-W309 FD page 77 Cabl page 311 FRU N 45 Cable-W310/313 2372183 FD page 77 Cabl page 311 FRU Y Trac N 45 Cable-W311 2372186 FD page 77 Cabl page 311 FRU Y Trac N 45 Cable-W312 FD page 77 Cabl page 312 FRU N 45 Cable-W313 FD page 77 Cabl page 312 FRU Y 2372183 Senographe DS 45 FRU/Component Index - Gantry Chapter 3 Cable-W303 Service Information and Procedures Class A 2385072-16-8EN Page no. 165 45 GE Healthcare Component Description Revision 1 Component-index.fm Class Comp. Loc FD Cabl CL FRU Trac 2345920-2 Loc page 196 FD page 77 Cabl page 313 FRU Y Trac N 45 Cable-W315 2345921 Loc page 197 FD page 77 Cabl page 314 FRU Y Trac N 45 Cable-W316 2372170 FD page 77 Cabl page 314 FRU Y Trac N 45 Cable-W317 2372171 FD page 77 Cabl page 314 FRU Y Trac N 45 Cable-W318 FD page 77 Cabl page 314 FRU N 45 Cable-W319 FD page 77 Cabl page 314 FRU N 45 Cable-W320 FD page 77 Cabl page 314 FRU Y 45 Cable-W401 FD page 78 Cabl page 314 FRU N 45 Cable-W402 FD page 78 Cabl page 314 FRU Y Trac N 45 Cable-W403 (Stator Cable) FD page 78 Cabl page 315 FRU Y Trac N 45 Cable-W404 FD page 78 Cabl page 315 FRU N 45 Cable-W405 FD page 78 Cabl page 315 FRU N 2372204 2345927 2381701-2 Loc page 196 Trac N D/R page 1217 Senographe DS Component-index.fm Cable-W314 Service Information and Procedures Class A 2385072-16-8EN Page no. 166 45 D/R GE Healthcare Reference Revision 1 Component Description FRU/Component Index - Gantry Chapter 3 Class Reference Comp. Loc FD Cabl CL FRU FD page 78 Cabl page 315 FRU N Trac D/R D/R page 1217 Cable-W407 2345932 FD page 78 Cabl page 316 FRU Y Trac N 45 Cable-W408 2372172 FD page 78 Cabl page 316 FRU Y Trac N 45 Cable-W409 FD page 78 Cabl page 317 FRU N 45 Cable-W410 FD page 78 Cabl page 317 FRU N 45 Cable-W411 FD page 78 Cabl page 318 FRU N 45 Cable-W412 Tube HV (4 conductor) 2379842 FD page 78 Cabl page 318 FRU Y Trac N 45 Cable-W413 FOV 2395068 FD page 78 FRU Y Trac N 45 Cable-W500 2377083 FD page 79 Cabl page 318 FRU N 45 Cable-W501 2377081 FD page 79 Cabl page 319 FRU N 45 Cable-W502 2377082-2 FD page 79 Cabl page 319 FRU N 45 Cable-W503 2377082-3 FD page 79 Cabl page 319 FRU N D/R page 1565 Senographe DS 45 FRU/Component Index - Gantry Chapter 3 Cable-W406 Service Information and Procedures Class A 2385072-16-8EN Page no. 167 45 GE Healthcare Component Description Revision 1 Component-index.fm Class Comp. Loc FD Cabl CL FRU Trac 2377179 FD page 79 Cabl page 320 FRU N 45 Cable-W505 2377179-2 FD page 79 Cabl page 320 FRU N 45 Cable-W506 2378515 FD page 79 Cabl page 320 FRU N 45 Cable-W507 2378516 FD page 79 Cabl page 321 FRU N 45 Cable-W508 2408704 FD page 79 Cabl page 321 FRU N 45 Cable-W509 2408705 FD page 79 Cabl page 321 FRU N 45 Cable-Water Hose Assy 2266812 FD page 74 FRU Y Trac N 45 Cable-Water Hose Assy blue 2266811 FD page 74 FRU Y Trac N 45 Footswitch-Left 2393691-2 Loc page 188 FD page 76 FRU Y Trac N 45 Footswitch-Right 2393690-2 Loc page 188 FD page 76 FRU Y Trac N 45 Keypad-Arm Control (on Tube Head, left and right) 5268425-2 Loc page 188 FD page 77 FRU Y 45 Light Assembly-Collimator 2377836 Loc page 195 FD page 78 FRU Y D/R page 1219 Trac N D/R page 1383 Senographe DS Component-index.fm Cable-W504 Service Information and Procedures Class A 2385072-16-8EN Page no. 168 45 D/R GE Healthcare Reference Revision 1 Component Description FRU/Component Index - Gantry Chapter 3 Class Reference Comp. Loc FD Cabl CL FRU Trac D/R Loc page 198 FD page 75 FRU Y Trac N 55 Brake-Compression-Manual 2345924 Loc page 193 FD page 77 FRU Y Trac N D/R page 1301 55 Brake-Compression-Motorized 2345915 Loc page 194 FD page 77 FRU Y Trac N D/R page 1309 55 Brake-Rotation + W219 2345969 Loc page 192 FD page 76 FRU Y Trac N D/R page 1247 55 Rotation Clutch + W218/W221 Cables 2345968-4 See Supplies on page 1227. See page 1227. Loc page 194 FD page 76 FRU Y Trac N D/R page 1227 55 Spare Part Kit Clutch 2345968-4 and Rotation Board 2375488-13 5265895-2 See Supplies on page 1227. See page 1227. Loc page 194 FD page 76 FRU Y Trac N D/R page 1227 55 Fan + W406 2345931 Loc page 195 FD page 78 FRU Y Trac N 55 Force Sensor + W319 2345925 Loc page 193 FD page 77 FRU Y Trac N D/R page 1313 55 Motor-Compression-Motorized 2345907 Loc page 194 FD page 77 FRU Y Trac N D/R page 1297 55 Motor-Lift + W205/206 See Supplies on page 1179 Loc page 192 FD page 76 FRU Y Trac N D/R page 1179 55 Motor-Rotation + W205/206 5212422 Loc page 191 FD page 76 FRU Y Trac N D/R page 1243 55 Motor-Tilt + W404 2345929 Loc page 195 FD page 78 FRU Y Trac N D/R page 1361 Senographe DS 2345987 FRU/Component Index - Gantry Chapter 3 Shunt R101 +W109/W111/W113 Service Information and Procedures Class A 2385072-16-8EN Page no. 169 45 GE Healthcare Component Description Revision 1 Component-index.fm Class Comp. Loc FD Cabl CL FRU Trac D/R FRU Y Trac N P-D/R page 824 2287261 55 Zero Sensor-Tube +W405 2345930 Loc page 195 FD page 78 FRU Y Trac N D/R page 1357 65 SFOV Collimator Box and Control Board Set (without Filter Wheel) and Interface Plate 2408847 Loc page 195 FD page 79 FRU Y Trac N D/R page 1369 65 Collimator Filter Wheel Assy. for system using Maxon motors 2324331-1 Loc page 195 FD page 79 FRU N Trac N D/R page 1375 65 HVL Attenuator- Set AL 99.99 2388637 FRU Y Trac N D/R page 1361 65 Entire Tilt Motor and Tilt Drive Assembly with Bearing 2345905 Loc page 195 FRU Y Trac N D/R page 1361 65 Tilt Drive Assembly 2392469 Loc page 195 FRU Y Trac N D/R page 1361 65 Compression Trolley Kit 5130573 Loc page 193 FRU Y Trac N D/R page 1337 75 Dust Reduction Kit 5394527 75 2D Crosshair Kit (comprising faceshield, frameholder and long/short rods) 5160716 75 Bearing-Tilt Drive 99033678 PMA254 page 1783 FRU Y Component-index.fm Loc page 195 FRU Y Trac N D/R page 1361 Senographe DS Sensor-Tube Thermal Cut Out Service Information and Procedures Class A 2385072-16-8EN Page no. 170 55 GE Healthcare Reference Revision 1 Component Description FRU/Component Index - Gantry Chapter 3 Class Reference Comp. Loc FD Cabl CL FRU Trac D/R Loc page 193 FRU Y Trac N D/R page 1299 75 Belt-Compr-Motorized-225mm 9mm 2374629 Loc page 194 FRU Y Trac N D/R page 1297 75 Belt -Guiding, Lower 2410101 FRU Y 75 Belt -Guiding, Upper 2410102 FRU Y 75 Belt-Lift 1830mm 25mm 2363778-1 Loc page 191 FRU Y Trac N D/R page 1189 75 Belt-Rotation-294mm 15mm 2260269-2 Loc page 191 FRU Y Trac N 75 Cable tie-Compression D70/ L250x4.8 2387733-5 FRU Y Trac N 75 Lift Screw Assembly (Type 2 or Type 3) See Supplies on page 1255 FRU Y Trac N D/R page 1255 75 Lift Screw Assembly Top Brake (Type 2 Lift Screw Assemblies only) 5198687 FRU Y Trac N D/R page 1279 75 Chain Energy-Compr 2388037 FRU Y Trac N 75 Clamp-Tube 75 Cover-Detector Upper. To replace 2375024 or 2375024-3 see J.C. D/R A210 on page 1197. 2375024-2 75 Cover-Detector Lower. To replace 2375025 or 2375025-3 see J.C. D/R A210 on page 1197. 2375025-2 Loc page 192 Loc page 194 46-208713P1 FRU Y P-D/R page 825 Loc page 189 FRU Y D/R page 523 Loc page 189 FRU Y D/R page 523 Senographe DS 2388175 FRU/Component Index - Gantry Chapter 3 Belt-Compr-Manual-600mm 10mm Service Information and Procedures Class A 2385072-16-8EN Page no. 171 75 GE Healthcare Component Description Revision 1 Component-index.fm Class Comp. Loc FD Cabl CL FRU Trac D/R 2411952 FRU Y D/R page 1197 75 Interface plate assy. Required if replacing 2375024/5 or 2375024/ 5-3; see J.C. D/R A210 on page 1197. 2408213 FRU Y D/R page 1197 75 Cover-Column Top Left. To replace 2375027 or 2375027-3 see J.C. D/R A210 on page 1197. 2375027-2 Loc page 189 FRU Y D/R page 523 75 Cover-Column Top Right. To replace 2375028 or 2375028-3 see J.C. D/R A210 on page 1197. 2375028-2 Loc page 189 FRU Y D/R page 523 75 Cover-Column Cable Exit. To replace 2375029 or 2375029-3 see J.C. D/R A210 on page 1197. 2375029-2 Loc page 189 FRU Y D/R page 523 75 Cover-Column Bottom Front. To replace 2375030 or 2375030-3 see J.C. D/R A210 on page 1197. 2375030-2 Loc page 189 FRU Y D/R page 523 75 Cover-Column Bottom Back. To replace 2375031 or 2375031-3 see J.C. D/R A210 on page 1197. 2375031-2 Loc page 189 FRU Y D/R page 523 75 Cover-Front Left. To replace 2375032 or 2375032-3 see J.C. D/R A210 on page 1197. 2375032-2 Loc page 189 FRU Y D/R page 523 75 Cover-Front Right. To replace 2375033 or 2375033-3 see J.C. D/R A210 on page 1197. 2375033-2 Loc page 189 FRU Y D/R page 523 75 Column Rear Cable Cover. 5133587 Loc page 189 FRU Y 75 Cover-Arm Left. To replace 2375037, 2375037-2, or 2375037-3, see J.C. D/R A210 on page 1197. 2375037-4 Loc page 189 FRU Y D/R page 523 Senographe DS Component-index.fm Quick-fix assy. for Detector covers. Required if replacing 2375024/5 or 2375024/5-3; see J.C. D/R A210 on page 1197. Service Information and Procedures Class A 2385072-16-8EN Page no. 172 75 GE Healthcare Reference Revision 1 Component Description FRU/Component Index - Gantry Chapter 3 Class Loc FD Cabl CL FRU Trac D/R Cover-Arm Right. To replace 2375038 or 2375038-2, or 2375038-3, see J.C. D/R A210 on page 1197. 2375038-4 Loc page 189 FRU Y D/R page 523 75 Cover-Head Left. To replace 2375043 or 2375043-3 see J.C. D/R A210 on page 1197. 2375043-2 Loc page 189 FRU Y D/R page 523 75 Cover-Head Right. To replace 2375044 or 2375044-3 see J.C. D/R A210 on page 1197. 2375044-2 Loc page 189 FRU Y D/R page 523 75 Cover-Compression Carriage Upper. To replace 2401145, 2375040 or 2375040-3 see J.C. D/R A210 on page 1197. 2401145-2 Loc page 189 FRU Y D/R page 523 75 Cover-Compression Carriage Lower. To replace 2375041 or 2375041-3 see J.C. D/R A210 on page 1197. 2401147 Loc page 189 FRU Y D/R page 523 75 Arm cover rework assy. Required when replacing older Arm, Compression, or Head covers; see J.C. D/R A210 on page 1197. 2412297 FRU Y D/R page 1197. 75 Handle-Main. See J.C. D/R A210 on page 1197. 2352894-2 Loc page 189 FRU Y D/R page 523 75 Curtain-Replacement kit. Includes lower and upper curtains. Replaces 2387673 and 2387675. 5131154 Loc page 188 FRU Y Trac N D/R page 1193 75 FOV Button 2395068 FRU Y Trac N D/R page 1391 75 Stop button (works on left or right hand side of Gantry) 2398573 Loc page 188 FRU Y 75 FaceShield 2372430 Loc page 188 FRU Y D/R page 1395 Senographe DS 75 GE Healthcare Comp. FRU/Component Index - Gantry Chapter 3 Reference Service Information and Procedures Class A 2385072-16-8EN Page no. 173 Component Description Revision 1 Component-index.fm Class Grid air-Tube Inlet 75 Comp. Loc FD Cabl CL FRU Trac Grid air-Tube Outlet 2399755-3 FRU Y 75 IQST-Phantom 2222686-2 FRU Y 75 Bucky top plastic cover 2390010 Loc page 189 75 Breast Support Latches 5195501 Loc page 188 75 Latch hook for Breast Support 2406045 FRU N 75 Latch assembly for image receptor 2410755 FRU Y 75 Logo-GE D60 75 Nut-Tube Cathode 2300174 75 Pulley and Torque limiter-Compression 2388164 75 Retaining Ring-Lift 91202713 FRU Y Trac N 75 Retaining Ring-Rotation 91202737 FRU Y Trac N 75 Screw-Tube CL M3x5/5 99051913 FRU Y 75 Screw-Tube CL M4x6/6 A2 50 99059598 FRU Y 75 Screw-Tube CL M4x8 99100033 FRU Y 75 Screw-Tube CL M4x8 PASS 99116464 FRU Y 75 Washer-Tube Cathode 2300175 FRU Y 75 Washer-Tube dents DEC M4 99132746 FRU Y 75 Zipper-Arm Harness 2390783 FRU Y 75 Tube Tilt Pivots 5412241 2399858-3 Loc page 188 FRU Y D/R page 1343 D/R page 1173 FRU Y Trac N FRU Y Loc page 193 FRU Y P-D/R page 826 DR page 1397 Senographe DS Component-index.fm FRU Y Service Information and Procedures Class A 2385072-16-8EN Page no. 174 2399754 D/R GE Healthcare 75 Reference Revision 1 Component Description FRU/Component Index - Gantry Chapter 3 Class Reference Comp. Loc 2337192 FD Cabl CL FRU Trac D/R FRU Y Trac N P-D/R page 823 Filter-Collimation LRS 85 Mag Stand-1.5 2372870-3 Loc page 190 FRU Y Trac N 85 Mag Stand-1.8 2372876-3 Loc page 190 FRU Y Trac N 85 Needle-Z-Stereotix-Tray kit 2389788-2 FRU Y Trac N 85 Paddle-Axillary 2389570 85 Paddle-Biopsy 2389571 85 Paddle-Biopsy Round Spot 2389572 85 Paddle-Phlexis This new replacement flexible paddle corrects the problem of the edge of the flexible compression paddle appearing in the chest wall side of some images due to an exaggerated tilting of the paddle. It replaces previous paddle with P/N 2395540-2. 85 Loc page 190 FRU Y FRU Y Loc page 190 FRU Y Paddle-Plate 19x23 Compress. 2241745 FRU Y 85 Paddle-Plate Square Compress. 2241747 FRU Y 85 Paddle-Round Spot 2389569 FRU Y 85 Paddle-Round spot MagMode 2397557 FRU Y 85 Paddle-Square Spot 2389568 Loc page 190 FRU Y Trac N Senographe DS FRU Y FRU/Component Index - Gantry Chapter 3 2395540-3 Service Information and Procedures Class A 2385072-16-8EN Page no. 175 85 GE Healthcare Component Description Revision 1 Component-index.fm Class Comp. Loc FD Cabl CL FRU Trac D/R 2397558 FRU Y 85 Paddle-Standard 19X23 2389414 85 Paddle-Standard MagMode 2397559 FRU Y 85 Paddle-Stereotix Compression kit (w/o window) 2389792 FRU Y Trac N 85 Paddle-Stereotix Compression kit (with window) 2389797 FRU Y Trac N 85 Plate-Stereotix-Breast Support Kit 2389789 FRU Y Trac N 85 19 X 23 Flexible Paddle Dampers FRU Kit. This new replacement flexible paddle kit for the 19 X 23 Flexible Paddle corrects the problem of the edge of the flexible compression paddle appearing in the chest wall side of some images due to an exaggerated tilting of the paddle. 5337715 FRU Y Trac N SWF 95 Gas Spring-Lift-450mm 5390061 replaces 2375828, 2375828-2, and 2412204. 5390061 Loc page 192 FRU Y Trac N D/R page 1183 95 Gas Spring-Rotation-160 mm 3000 N (5154719 replaces 2412202 and 2362540) 5154719 Loc page 191 FRU Y Trac N D/R page 1251 95 Gas Spring for Rotation Worm Gear-100 N 2412203 Loc page 191 FRU Y Loc page 193 FRU Y Trac N D/R page 1235 Senographe DS Component-index.fm Service Information and Procedures Class A 2385072-16-8EN Paddle-Square spot MagMode Page no. 176 85 GE Healthcare Reference Revision 1 Component Description FRU/Component Index - Gantry Chapter 3 Class Component Description Reference Comp. Loc FD Cabl CL FRU Trac D/R D/R page 1553 Loc page 214 FRU Y Trac N 15 Capacitor-2200µF 350V 58079856 Loc page 215 FRU Y Trac N 15 Capacitor-330000µF 63V 99091203 FRU Y Trac N 15 Capacitor 2.5UF 45067136 FRU Y Trac N 15 Capacitor-ALU 100UF 99182146 FRU Y Trac N 15 Diode-Bridge 120A (D26, D27) 91707991 Loc page 215 FRU Y Trac N 15 Diode-Bridge 60A (D24, D25) 91707990 Loc page 215 FRU Y Trac N 15 Diode-Module 1.4kV 60A 58079525 Loc page 214 FRU Y Trac N 15 Electronic Component-Misc 2326402 FRU Y Trac N 15 Electronic Component-Misc 2326401 FRU Y Trac N 15 Fuse, 250 Vac, 1 A, Delay (F1 on Mains Distribution Board) 58079686 Loc page 263 FRU Y Trac N D/R page 1109 15 Fuse, 600 Vac, 35 A, Fast (F1/F2 next to Generator S1 Switch and K1 Contactor) 99184154 Loc page 215 FRU Y Trac N D/R page 1109 15 Fuse, 250 Vac, 3.15 A, Delay (F1 on Supply Command Board) 99194288 Loc page 270 FRU Y Trac N D/R page 1109 Chapter 3 Senographe DS 2110227 FRU/Component Index - Generator Cabinet Capacitor Unit Service Information and Procedures Class A 2385072-16-8EN Page no. 177 15 GE Healthcare Class Chapter 3 Revision 1 Component-index.fm FRU/Component Index - Generator Cabinet 15 Fuse, 250 Vac, 0.5 A, Delay (F2 on Supply Command Board, and F2/F3 on Mains Distribution Board) 58079685 15 Fuse, 150 Vac, 125 A, Fast (F3 on Supply Command Board) 15 Comp. Loc FD Cabl CL D/R Loc page 270 & page 263 FRU Y Trac N D/R page 1109 91684676 Loc page 270 FRU Y Trac N D/R page 1109 Fuse, 380 Vac, 10 A, Fast (F4/F5 on Supply Command Board) 58079166 Loc page 270 FRU Y Trac N D/R page 1109 15 Fuse, 250 Vac, 16 A, Fast (F6 on Supply Command Board) 58079690 Loc page 270 FRU Y Trac N D/R page 1109 15 Fuse, 250 Vac, 10 A, Delay (F1 on Mains Distribution Assembly) 99183979 Loc page 281 FRU Y Trac N D/R page 1109 15 Fuse, 250 Vac, 5 A, Delay (F2/F4 on Mains Distribution Assembly) 99183923 Loc page 281 FRU Y Trac N D/R page 1109 15 Fuse, 250 Vac, 1.6 A, Delay (F3 on Mains Distribution Assembly) 99183925 Loc page 281 FRU Y Trac N D/R page 1109 15 Fuse, 250 Vac, 1.0 A, Delay (F5 on Mains Distribution Assembly) 99183936 Loc page 281 FRU Y Trac N D/R page 1109 15 Fuse, 250 Vac, 2.5 A, Delay (F1/F2/F3 on Command Supply Board) 99194291 Loc page 251 FRU Y Trac N D/R page 1109 15 Inductor-Filtering 2X125 UH 45066952 Loc page 214 FRU Y Trac N 15 Jumper-Red 99171545 Loc page 216 FRU Y Trac N 15 Transistor-2N 60V 99023151 FRU Y Trac N Senographe DS Component-index.fm Trac Service Information and Procedures Class A 2385072-16-8EN Page no. 178 FRU GE Healthcare Reference Revision 1 Component Description FRU/Component Index - Generator Cabinet Chapter 3 Class 15 Transistor-2N 75V 0.8A 25 Board-Anode Starter Power 300PL2 25 Board-CPU Generator 400PL3 25 Generator CPU Board EEPROMs 25 Reference Comp. Loc FD Cabl CL 99048606 FRU Trac D/R FRU Y Trac N FRU Y Trac N D/R page 1609 5399150 Loc page 216 FD page 81 CL page 240 FRU Y Trac Y D/R page 1543 See Supplies on page 1625 Loc page 216 FD page 81 CL page 240 FRU Y Trac Y D/R page 1625 Board-Generator Command 400PL1 2107747-2 Loc page 216 FD page 81 CL page 251 FRU Y Trac N D/R page 1569 25 Board-Generator Interface 400PL2 2198369-3 Loc page 216 FD page 81 FRU Y Trac N D/R page 1577 25 Board-Inverter 2121509-2 Loc page 214 FD page 81 FRU Y Trac N D/R page 1595 25 Board-Main Distribution 200PL1 2108592-2 Loc page 212 FD page 81 FRU Y Trac N D/R page 1601 25 Board-Relay Board 200PL4 2106963-2 Loc page 212 FD page 81 FRU Y Trac N D/R page 1591 25 Board-Supply Command 200PL2 2121398-2 Loc page 212 FD page 81 FRU Y Trac N D/R page 1583 25 Interface-Operator 2221381 Loc page 213 FD page 80 FRU Y Trac N 25 Interface-Service 2221383 Loc page 213 FD page 80 FRU Y Trac N Senographe DS FD page 81 FRU/Component Index - Generator Cabinet Chapter 3 Loc page 214 Service Information and Procedures Class A 2385072-16-8EN Page no. 179 45553694-2 GE Healthcare Component Description Revision 1 Component-index.fm Class Comp. Loc FD 2102774 Loc page 212 FD page 81 2203685-2 Loc page 212 FD page 81 Power Line Filter Box 25 BT Power Supply 400T1 35 Autotransformer 9kW 415V 2262737 Loc page 215 35 Transformer 2kVA 2228007 Loc page 213 35 Battery 3.6V 2315533 35 Battery-Lithium for CPU 850mAh 35 CL FRU Trac D/R FRU Y Trac N D/R page 1617 D/R page 1613 Trac N FRU Y Trac N Loc page 212 FRU Y Trac N 99171019 Loc page 216 FRU Y Trac N Circuit Breaker 25A 5352939 Loc page 213 FRU Y Trac N 35 Holder-Fuse 2P 600V 91685123 Loc page 215 FRU Y Trac N 35 Relay-18A 230V 2327235 Loc page 215 FRU Y Trac N 35 Relay-K1 K2 8A 2100312 Loc page 212 FRU Y Trac N 35 Relay-X1 16A 91682082 Loc page 212 FRU Y Trac N 35 Resistor-coiled 160W 99120760 Loc page 212 FRU Y Trac N FD page 80 FD page 80 D/R page 1549 Senographe DS Component-index.fm FRU Y Service Information and Procedures Class A 2385072-16-8EN Page no. 180 25 Cabl GE Healthcare Reference Revision 1 Component Description FRU/Component Index - Generator Cabinet Chapter 3 Class Reference Comp. Loc FD Cabl CL FRU Trac Loc page 212 FRU Y Trac N 35 Switch-Main Emergency 91717300 Loc page 215 FRU Y Trac N 35 Thermostat 40/30° 58079253 Loc page 214 FRU Y Trac N 35 Thermostat 55/45° 58079252 Loc page 214 FRU Y Trac N 35 Thyristor 58079220 Loc page 214 FRU Y Trac N 45 Cable (400PL1-200PL2) 2110259 Loc page 217 FRU Y Trac N 45 Cable (400PL1-200PL2) 2110271 Loc page 217 FRU Y Trac N 45 Cable (400PL1-300PL1) 2110262 Loc page 217 FRU Y Trac N 45 Cable (400PL1-300PL2) 2110264 Loc page 217 FRU Y Trac N 45 Cable (40-P 0.5 M) C801418 Loc page 217 FRU Y Trac N 45 Cable (Heater and BIAS) 45474577 Loc page 217 FRU Y Trac N 45 Cable (Line supply W14) 2111145 Loc page 215 FRU Y Trac N Senographe DS 99182099 FRU/Component Index - Generator Cabinet Chapter 3 Resistor-coiled 280W Service Information and Procedures Class A 2385072-16-8EN Page no. 181 35 D/R GE Healthcare Component Description Revision 1 Component-index.fm Class Comp. Loc FD Cabl CL FRU Trac 2110067 Loc page 215 FRU Y Trac N 45 Cable (REL/CTRS, W10) 2110066 Loc page 215 FRU Y Trac N 45 Cable-250V Distribution 2110070 Loc page 212 FRU Y Trac N 45 Cable-Coaxial (HV Unit/IC) Alt A 45203148 Loc page 212 FRU Y Trac N 45 Cable-Coaxial (HV Unit/IC) Alt B 45203215 Loc page 212 FRU Y Trac N 45 Cable-Conditioner - Pos Harness 2387792 FRU Y Trac N 45 Cable-CPU Power Supply 45440115 Loc page 212 FRU Y Trac N 45 Cable-Data Control 45440116 Loc page 212 FRU Y Trac N 45 Cable-Gene pos Harness 2387764 FRU Y Trac N 45 HV Tank Unit 701 2107399 Loc page 212 FD FRU Y Trac Y 45 Line Filter 250V 2229249 Loc page 213 FD page 80 FRU Y Trac N 45 Mains Distribution Assy 2221053-2 Loc page 213 FD page 80 FRU Y Trac N 45 Power Supply 220V 12V 2228060 Loc page 213 FD page 80 FRU Y Trac N D/R page 1559 Senographe DS Component-index.fm Cable (PSRS/CTRS, W12) Service Information and Procedures Class A 2385072-16-8EN Page no. 182 45 D/R GE Healthcare Reference Revision 1 Component Description FRU/Component Index - Generator Cabinet Chapter 3 Class Reference Comp. Loc FD Cabl CL FRU Trac D/R P-D/R page 821 2264280 Loc page 216 FRU Y Trac N 55 Fan-Generator Cabinet 2331316 Loc page 211 FRU Y Trac N 65 Conditioner 2387548 Loc page 212 FRU Y Trac Y 75 Cable tie D22/L99x2.5 99020256 FRU Y Trac N 75 Conduit 2191670 FRU Y Trac N 75 Cover-Top (packaged FRU) 2235112-2 Loc page 211 FRU Y Trac N D/R page 513 75 Cover assembly-Rear including fan (packaged FRU) 2235113-2 Loc page 211 FRU Y Trac N D/R page 513 75 Cover-Front (packaged FRU) 2235114-2 Loc page 211 FRU Y Trac N D/R page 513 75 Cover-Left (packaged FRU) 2235115-2 Loc page 211 FRU Y Trac N D/R page 513 75 Cover-Right (packaged FRU) 2235116-2 Loc page 211 FRU Y Trac N D/R page 513 75 Jack-Fixed 91719024 Loc page 214 FRU Y Trac N 75 Protective cover-PL200/PL201 45563301 Loc page 212 FRU Y Trac N 75 Screw-Hexagon Socket head Cap M4 99059808 FRU Y Trac N 75 Screw-Slotted M2.5 99057154 FRU Y Trac N D/R page 1633 Senographe DS FRU/Component Index - Generator Cabinet Chapter 3 Power Supply 50W 5V Service Information and Procedures Class A 2385072-16-8EN Page no. 183 45 GE Healthcare Component Description Revision 1 Component-index.fm Class 75 Tubing-Shrink Wht D12.7/6.4 99002536 75 Wheel-Transportation 91727258 115 Coolant kit 2355459 Comp. Loc FD Cabl CL FRU Trac FRU Y Trac N Loc page 214 FRU Y Trac N Loc page 212 FRU Y Trac N D/R D/R page 1633 GE Healthcare Reference Revision 1 Component Description FRU/Component Index - Generator Cabinet Chapter 3 Class Senographe DS Component-index.fm Service Information and Procedures Class A 2385072-16-8EN Page no. 184 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN FRU/Component Location FRU/Component Location 1. Chapter 3 SCOPE This section includes information intended to assist in the location of Components as defined in the Component Index. A component is not necessarily a FRU (Field Replaceable Unit). When searching for FRUs, note that all FRUs are listed in the Component Index, but their locations may not be shown here. 2. NAVIGATION PRINCIPLES The first illustration is a top-level illustration which shows the Senographe system. Illustrations of the main component assemblies (Gantry, Generator, Control Station) follow the top-level illustration of the Senographe system. Successive levels of illustration show more detail. ! Notice: If you are viewing an original Acrobat PDF document on screen, illustrations appear in color, and you can use hypertext links to navigate the document. • Hypertext links are highlighted in blue. They are either blue text, or areas of illustrations outlined in blue. • FSU/FRU titles are shown in blue. In the final document you can click these titles and obtain component information (part number, etc.). • • If you see a folder icon beside an assembly title shown in blue, you can click the title to jump to a lower level illustration showing components and sub-assemblies. The table on the following page shows other navigation buttons. Page no. 185 Location-FRU.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN FRU/Component Location Navigation buttons: Click this button to jump to an illustration showing the opposite side of the assembly These buttons are used when an illustration is too large to fit on the page. Click the up arrow to move the view upwards. Click the down arrow to move the view downwards. This folder icon is placed beside title text when a lower level illustration with more information is available. Click the title to move down one level. Click one of these buttons to jump to an illustration showing the same assembly from another point of view. Chapter 3 Page no. 186 Location-FRU.fm GE Healthcare Senographe DS Service Information and Procedures Class A 2385072-16-8EN Page no. 187 ACQUISITION SYSTEM COMPONENTS Revision 1 3. Location-Nephtys.fm Generator Control Station Gantry Covers Detector Supply Tube Head CPU Board Faceshield Stop Latches Rotation/Lift Bulkhead Right Footswitch Left Footswitch Gantry Readout Senographe DS Location-Nephtys.fm Curtains Service Information and Procedures Class A 2385072-16-8EN Page no. 188 Compression Arm PDU Board Supply Gantry - MPCB Accessories GE Healthcare GE Logo Revision 1 Arm control keypad 3-1. Arm control keypad GE Healthcare Senographe DS Revision 1 3-1-1. Service Information and Procedures Class A 2385072-16-8EN Gantry Covers Tube head covers Main Handle Compression Carriage covers Cable Exit covers Bucky Top Cover Top Column covers Front covers Detector covers Arm covers Left Bottom Column covers Gantry Covers (full list) • Column covers - Cable Exit cover - Top Column cover (left and right) - Bottom Column covers (front and rear) - Front covers (left and right) • Compression and Arm covers - Compression Carriage cover - Arm covers (left and right) • Tube Head covers (left and right) • Detector covers (upper and lower) Page no. 189 Location-Nephtys.fm Right GE Healthcare Revision 1 3-1-2. Senographe DS Service Information and Procedures Class A 2385072-16-8EN Accessories • 19 x 23 cm compression paddle • Small round spot compression paddle • Axillary compression paddle • Square spot compression paddle • Two magnification platforms (or Mag Stand) with latches. Mag Stand 1.5 Mag Stand 1.8 Page no. 190 Location-Nephtys.fm Page no. 191 Rotation Optical Fork Rotation Board Rotation Gas Spring Not Illustrated: Lift Synchronous Belt Senographe DS Service Information and Procedures Class A 2385072-16-8EN Rotation Potentiometer GE Healthcare Rotation Belt Rotation /Lift - Front View Rotation Worm Gear Gas Spring Revision 1 3-1-3. Location-Gantry_DS.fm Rotation Motor + Encoder Lift Screw Assembly Page no. 192 Rotation Brake Lift Lower Optical Fork Lift Potentiometer Lift Motor + Encoder Lift Board Senographe DS Location-Gantry_DS.fm Service Information and Procedures Class A 2385072-16-8EN Lift Gas Spring GE Healthcare Lift Upper Optical Fork Rotation /Lift - Rear View Lift Screw Assembly Ball Baring Ring Revision 1 3-1-4. Lift Screw Assembly Brake Force Sensor Arm Distribution Board Paddle Standard 19 x 23 Bucky Assembly Bucky Board Senographe DS Image Receptor Image Digital Detector GE Healthcare Pulley and Torque Limiter Service Information and Procedures Class A 2385072-16-8EN Page no. 193 Paddle Holder Board Manual Compression Belt Compression Arm - Front Brake - Manual Compression Revision 1 3-1-5. Location-Gantry_DS.fm Compression Trolley Kit Motor Pulley Motorized Compression Belt Compression Board Senographe DS Location-Gantry_DS.fm Rotation Clutch GE Healthcare Compression Motor + Encoder Service Information and Procedures Class A 2385072-16-8EN Page no. 194 Compression Potentiometer Compression Arm - Rear Compression Energy Chain Revision 1 3-1-6. Brake for Motorized Compression GE Healthcare Tube Head Tube Head Zero Sensor Revision 1 3-1-7. Location-Gantry_DS.fm Tilt Drive Assembly Tube Tilt Motor Tilt Drive Bearing Tube Tilt Board Page no. 195 Control Board Collimator Set Fan Filter Wheel Senographe DS Light Assembly Service Information and Procedures Class A 2385072-16-8EN DC/DC Board PL104 Senographe DS Location-Gantry_DS.fm Cable W402 Service Information and Procedures Class A 2385072-16-8EN Cable W101 GE Healthcare Interface Board CPU Board PL103 MPCB - CPU Board Page no. 196 Cable W314 Revision 1 3-1-8. Cable W116 Cable W208 Cable W110 Cable W125 Cable W104 Senographe DS Cable W111 Service Information and Procedures Class A 2385072-16-8EN Fuses F5, F6 Cable W107 Cable W209 GE Healthcare Cable W101 MPCB - PDU Board Page no. 197 Fuses F1, F3, F4 Revision 1 3-1-9. Location-Gantry_DS.fm Stop Motion Left PDU Board PL101 Cable W315 Cable W112 Cable W108 Cable W105 GE Healthcare Fuse 20A Senographe DS Location-Gantry_DS.fm Service Information and Procedures Class A 2385072-16-8EN Cable W117 Revision 1 Cable W109 Page no. 198 EMC Filter E102 Shunt R101 Terminal Block ST102 3-1-10. MPCB - Supply Cable W110 Cable W113 Cable W106 Cable W005 Cable W004 EMC Filter E101 Circuit Breaker 10A Terminal Block ST101 Cable W002 Cable W001 Senographe DS Cable W127 Service Information and Procedures Class A 2385072-16-8EN Page no. 199 Cable W006 GE Healthcare Input I/F Board PL102 Revision 1 AC/DC Converter Module 3-1-11. MPCB - Bulkhead area Location-Gantry_DS.fm Cable W107 GE Healthcare Detector power Supply Senographe DS Location-Gantry_DS.fm Service Information and Procedures Class A 2385072-16-8EN Page no. 200 Detector ac supply cable Revision 1 Detector power cable 2386549 3-1-12. Detector Power Supply Detector supply to IDC 2226621 Mouse AWS Keyboard CS V1/V2 Right View CS V3 Right View CS V4 Left View CS V4 Right View Senographe DS CS V3 Left View Service Information and Procedures Class A 2385072-16-8EN Page no. 201 X-Ray Console Omega Cover GE Healthcare Control Station LCD Monitor Rotative Arm Ergotron or Sisfle CS V1/V2 Left View Revision 1 3-2. Location-CS_DS.fm Radiation Screen GE Healthcare Senographe DS Location-CS_DS.fm Service Information and Procedures Class A 2385072-16-8EN UPS Control Station V1/V2 Left Side Page no. 202 ADS Software Ethernet Switch ADS Computer SB150 with CD Writer Revision 1 3-2-1. Keyboard Slider Rails IDC Software Keyboard Slider Rails Senographe DS Service Information and Procedures Class A 2385072-16-8EN IDC GE Healthcare Bucky Support Control Station V1/V2 Right Side Page no. 203 Modem Revision 1 3-2-2. Location-CS_DS.fm Top Cover ADS Computer U20 ADS Software Senographe DS Ethernet Switch (Penduick and above) Service Information and Procedures Class A 2385072-16-8EN RJ-45 Service Panel GE Healthcare Control Station V3 Left Side Page no. 204 UPS Revision 1 3-2-3. Location-CS_DS.fm Keyboard Slider Rails IDC GE Healthcare UPS Senographe DS Location-CS_DS.fm Service Information and Procedures Class A 2385072-16-8EN Page no. 205 IDC Software Revision 1 Keyboard Slider Rails Control Station V3 Right Side Top Cover 3-2-4. Handswitch Ethernet Switch (Pre-Penduick) IDC ADS Computer Z400 ADS Software Senographe DS Ethernet Switch Service Information and Procedures Class A 2385072-16-8EN RJ-45 Service Panel GE Healthcare Control Station V4 Left Side Page no. 206 UPS Revision 1 3-2-5. Location-CS_DS.fm Keyboard Slider Rails IDC GE Healthcare Control Station V4 Right Side Top Cover Keyboard Slider Rails UPS Senographe DS Location-CS_DS.fm Service Information and Procedures Class A 2385072-16-8EN Page no. 207 IDC Software Revision 1 3-2-6. Handswitch IDC Mouse Mat Mouse Mat Support Note: The Ergotron rev 2 Rotative Arm Set is a FRU, and the components listed above are also available separately as a FRU. Senographe DS Arm Handle GE Healthcare Monitor and Mouse Support Service Information and Procedures Class A 2385072-16-8EN Rotative Arm Set (Ergotron rev 2) Page no. 208 Optional Trackball Revision 1 3-2-7. Location-CS_DS.fm Monitor Fixation 30 mm Monitor Cable Harness (not shown) Silicone Masks Location-CS_DS.fm Mouse Mat Support Note: The Sisfle Rotative Arm Set is a FRU, and the components listed above are also available separately as a FRU. Senographe DS Arm Handle Service Information and Procedures Class A 2385072-16-8EN Page no. 209 Mouse Mat Rotative Arm Set (Sisfle Arm) Stop Screw GE Healthcare Monitor Fixation Revision 1 3-2-8. Stop Bracket Set GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN This page is blank. Page no. 210 Location-CS_DS.fm GE Healthcare Senographe DS Revision 1 3-2. Service Information and Procedures Class A 2385072-16-8EN Generator Cabinet 3-2-1. Generator + Conditioner Cabinet Top Cover Generator Left Cover Generator Rear Cover Generator Generator Cooling Fan Front Cover Generator Right Cover Generator FRU detail: Illustration 3-2-4, 3-2-5, 3-2-6, 3-2-7 Page no. 211 Location-Gene.fm GE Healthcare Revision 1 3-2-2. Senographe DS Service Information and Procedures Class A 2385072-16-8EN Generator + Conditioner Cabinet (continued) Conditioner Coolant kit for install or replace Coaxial cable HVunit/IC 200PL4 Relay board 701HV unit Line Filter Box Mains distribution board 200PL1 • Relay K1, K2 • Relay X1 • Coiled Resistor 280W • Coiled Resistor 160W Protective cover between 200PL1 and 200PL2 CPU Power supply cable Data control cable 250 V distribution cable (WG4) 200PL2 Supply command board • Fast Fuse 27X27 125A 150VAC • Fuse 10A 380V Page no. 212 Location-Gene.fm GE Healthcare Revision 1 3-2-3. Senographe DS Service Information and Procedures Class A 2385072-16-8EN Generator + Conditioner Cabinet (continued) Service Interface Line filter 250VAC Operator Interface Circuit breaker Power supply 220V 0.5A Transformer 2kVA Page no. 213 Location-Gene.fm Mains distribution GE Healthcare Senographe DS Revision 1 3-2-4. Service Information and Procedures Class A 2385072-16-8EN Generator with HV Unit Fixed jack D=40 M10X25 HR:43 Transportation wheel D2X50mm A 300PL1 Inverter Board 300-PL2 Anode Starter Power Board Thermostat 55/45oC 1R 6A F6 Thermostat 40/30oC 1T 6A F6 Thyristor (TH1) (TH2) Filtering inductor 2X125 A Diode module DD31N 1.4 KV 60A Capacitor unit Page no. 214 Location-Gene.fm GE Healthcare Revision 1 3-2-5. Senographe DS Service Information and Procedures Class A 2385072-16-8EN Generator with the HV Unit (continued) Main Emergency switch Relay 18 A 230 V 22 V Fuse Holder 2P 60x27 600V Fast Fuse 27x60 35A 600V C 100KA Cable PSRS/CTRS (W12) Cable REL/CTRS (W10) Transformer 9kW 52A 415V Capacitor AL 2200µF 350V Diode DD31N400K (D24, D25) Line Supply Contactor cable (W14) Diode DD61N400K (D26, D27) Page no. 215 Location-Gene.fm GE Healthcare Senographe DS Revision 1 3-2-6. Service Information and Procedures Class A 2385072-16-8EN Generator with the HV Unit (continued) A 400-PL3 CPU Gene. Jumper, red Battery, lithium 400-PL2 Gene. Interface Board 400-PL1 Generator Command Board Power supply 50W 5V5A 12V2A - 12V0.5A A Page no. 216 Location-Gene.fm GE Healthcare Revision 1 3-2-7. Senographe DS Service Information and Procedures Class A 2385072-16-8EN Generator with the HV Unit (continued) Cable 40-cond. 0.50 m Cable 400PL1 - 200PL2 Cable 400PL1 - 300PL2 Cable 400PL1 - 300PL1 Cable 400PL1 - 200PL2 Heater & bias cable Page no. 217 Location-Gene.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN This page is blank. Page no. 218 Location-Gene.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Tools Glossary Tools Glossary Chapter 3 This section describes the tools and consumable supplies that are required to install and maintain the Senographe system. It is organized logically in the following sections: • Mechanical Tools - Standard Mechanical Tools - Professional Mechanical Tools • Specified Tools - Specific Maintenance Tools - Image Quality Tools - Measuring Meters - Loopback Kit • Consumable Supplies Page no. 219 Tool-Glossary.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Tools Glossary 1. MECHANICAL TOOLS 1-1. Standard Mechanical Tools The following table summarizes all of the standard mechanical tools that must exist in a Standard Tool Box. These tools are required for every site visit in order to perform installation and routine maintenance of the Senographe system. Standard Mechanical Tools Set of allen metric wrenches: 1.5 mm - 2 mm - 2.5 mm - 3 mm - 4 mm 5 mm - 5.5 mm - 6 mm - 8 mm Set of imperial allen wrenches including the size 3/32" American wrench 3/16" Set of metric open-ended wrenches: 5.5 mm - 7 mm - 8 mm - 13 mm - 17 mm Adjustable pin wrench: Ratchet handle (1/4" Square Drive) 10 Piece Metric Standard Hex Socket Set (1/4" Square Drive) : 4 mm, 5 mm, 6 mm, 7 mm, 8 mm, 9 mm, 10 mm,11 mm, 12 mm, 13 mm) 10 Piece SEA Standard Hex Socket Set (1/4" Square Drive) : 5/32", 3/16", 7/32", 1/ 4", 9/32",5/16", 11/32", 3/8", 7/16", 1/2") Chapter 3 Page no. 220 Tool-Glossary.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Tools Glossary Standard Mechanical Tools 13 mm Hex Socket (1/4" Square Drive) Socket Extension Bars (1/4" Square Drive) Combination pliers Circlip pliers Bent needle-nose pliers Page no. 221 Tool-Glossary.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Tools Glossary Standard Mechanical Tools Channel lock pliers Set of Feeler Gauges (from 0.03 mm to 1 mm) Torque Wrench (3 - 30 N.m) Soldering Iron Chapter 3 Page no. 222 Tool-Glossary.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Tools Glossary Standard Mechanical Tools ESD Strap Spirit level or similar device for measuring horizontality, accuracy ±0.5° Protractor or suitable device for measuring angles of 5° and 15°, accuracy ±0.5° Vernier calipers 3 m measuring tape Page no. 223 Tool-Glossary.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Tools Glossary Standard Mechanical Tools Screwdriver set, including large and small flat and cross-head screwdrivers Spatular (or slim flat blade) Vacuum Cleaner Chapter 3 Page no. 224 Tool-Glossary.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Tools Glossary 1-2. Professional Mechanical Tools The following table summarizes all of the professional mechanical tools that do not have to exist in a Standard Tool Box. Professional mechanical tools cannot be ordered from GE, but can be sourced from any professional hardware store. These tools are only required when changing a few components in the Senographe system. Tools Where Used Bearing Jaw Puller Axial Lock Nut Socket (for KM15 Lock Nuts - 98 mm diameter) HN15 Hook Spanner (for KM15 Lock Nuts - 98 mm diameter) Bearing Fitting Tool Kit (SKF) Hub Extractor Job Card D/R A205 - Lift Motor on page 1179 Job Card D/R A228 - Rotation Motor on page 1243 Job Card D/R A244 - Compression Motor with Encoder and Compression Belt on page 1297 Minimum specifications: jaw reach > 100 mm, jaw spread > 90 mm. Suitable models are the Grainger 4YT15 and Belzer 4532-0. Page no. 225 Tool-Glossary.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Tools Glossary 2. SPECIFIED TOOLS This section is not exhaustive; it lists tools which can be required for specified tasks. They can be supplied with the system, or by the Field Engineer. 2-1. Specific Maintenance Tools Tools PN Orderable How supplied 2247879-4 Y In system accessory kit Purge Tool 2249359 Y In system accessory kit Service terminal cable EMC 2116257 Y In system accessory kit Magstand simulator 5376101 Y In system accessory kit and FE supply N FE supply Y FE supply Loopback kit Standard RS-232 Loopback Adapter Breakout Box with cables Chapter 3 2252056 Where Used Page no. 226 Tool-Glossary.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Tools Glossary Tools Sisfle Rotative Arm Tool PN Orderable How supplied Where Used 5271823 Y FE supply Job Card PHY A009 - Opposite Side Rotative Arm Installation on page 415 Job Card D/R A319 - Rotative Arm on page 1483 7 mm wedge for Breast Support alignment N/A N Supplied with Breast Support Latches FRU 36003399 Y FE supply Two sheets of 0.2 mm and 0.5 mm thickness of 99.9% pure aluminum. Length and width sufficient to cover fully the ionization chamber. The thickness must be accurate within ±1%. N FE supply Lead sheet N 24 x 30 cm mammographic cassette with film N Hospital One coin N FE supply Job Card ELE A028 - Collimation Checks on page 679 HV unit/cable adaptor Job card D/R A257 - Breast Support Latches on page 1173 Parallel Key 2X2X14MM 2201766-10 Y FE supply Used to change Pulley Motor on Compression Arm Parallel Key 3X3X18MM 2201766-12 Y FE supply Used to change Pulley Motor on Compression Arm N FE supply Y FE supply Small Static Duster Gantry LOTO Tool 5337232 Page no. 227 Tool-Glossary.fm Job Card D/R A232 - Lift Screw Assembly on page 1255 Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Tools Glossary 2-2. Image Quality Tools The following table summarizes the recommended Image Quality tools (e.g. phantoms, acrylic plates) that you can use to perform Image Quality measurements on the Senographe system. Tools Set of acrylic plates PN Orderable How supplied 2299008-2 N With system (part of option S30321MP) 2222686-2 Y FE supply 2233248 Y In system accessory kit Comprises six 10 mm acrylic plates and one 5 mm acrylic plate. The acrylic plates in this set can be stacked to create different thicknesses. IQST standard phantom Flat Field Phantom ACR Standard Phantom - 16 cells Nuclear Associates 18-220 Chapter 3 Page no. 228 Tool-Glossary.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Tools Glossary Tools PN Orderable How supplied Detector Protection Plate 5162279 Y In system accessory kit GAFCHROMIC® XR-M Film 5324611 Y FE Supply Aluminum attenuator plate (used for Collimator checks) 5330673 Y FE Supply ACR Standard Phantom - RMI-156 Page no. 229 Tool-Glossary.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Tools Glossary 2-3. Measuring Meters The following section summarizes the recommended meters that you can use to perform different types of measurements on the Senographe system. 2-3-1. kVp Meters The table below summarizes the recommended kVp meters that you can use to perform kVp measurements on the Senographe system. kVp Meter PN Orderable How supplied 2384916 Y FE supply RMI 232 kVp meter N FE supply Keithley 35080B kVp meter N FE supply Radcal 4082 kVp meter Chapter 3 Page no. 230 Tool-Glossary.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Tools Glossary 2-3-2. Dosimeters The table below summarizes the recommended dosimeters (and associated accessories) that you can use to perform ionization measurements on the Senographe system. Dosimeter/accessory PN Orderable How supplied Dosimeter Radcal 2026 2213942 Y FE supply Chamber for dosimeter 2026 (mammo) 2213938 Y FE supply Y In system accessory kit 6M ionization chamber (6cc) calibrated at mammographic X ray beam energies Dosimeter Support (with Radiation Protection Plate) Radiation Protection Plate 2238777 In system accessory kit Included with the Dosimeter Support Page no. 231 Tool-Glossary.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Tools Glossary 2-3-3. Multimeters and mA-mAs Meters The table below summarizes the recommended multimeters and mA-mAs meters that you can use to perform various voltage, resistance, and current measurements on the Senographe system. Meter PN Orderable How supplied 12062-Fluke 87 type 5 Y FE supply N FE supply Y FE supply Multimeters Fluke 87 multimeter first generation, type III, and type V Fluke 8060 multimeter GS Poner 165 mA-mAs meter Keithley 35035 mAs meter Chapter 3 46-194427P435 Page no. 232 Tool-Glossary.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Tools Glossary 2-3-4. Luminance Meters The table below summarizes the recommended luminance meters that you can use to perform luminosity measurements in hospital rooms that accommodate the Senographe system. Luminance Meter PN Orderable How supplied 46-262762G1 or G2 Y FE supply Siemens luminance meter (Wellhoffer Serial Spot Meter) 2319223 Y FE supply Minolta Luminance Meter LS100/110 or CS100 2109716 Y FE supply IET Luminance meter kit Page no. 233 Tool-Glossary.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Tools Glossary 2-3-5. Mammography Compression Scales The table below summarizes the recommended compression scales that you can use to perform compression calibration measurements on the Senographe system. Mammography Compression Scale PN Orderable How supplied Mammography compression scale with digital display 46-194427P407 Y FE supply 2-3-6. X-ray Waveform Meters The table below summarizes the recommended X-ray waveform meters that you can use to perform Xray waveform measurements on the Senographe system. X-ray waveform meters PN Orderable How supplied X-ray waveform meter RMI 233 and oscilloscope 2-4. Loopback Kit The loopback kit (PN 2247879-4) comprises various parts, which are used to perform loopback tests on the different components of the Senographe system. The loopback kit is supplied within the Senographe system accessory kit (PN 2383183-4). The loopback kit is an orderable FRU, and all of the parts of the loopback kit are also orderable as a FRU. Some of these parts are also used in the actual Senographe system. The following table summarizes the loopback kit parts in terms of their function, part number, and whether there are also used elsewhere within the Senographe system. The parts that are also used elsewhere within the Senographe system are also listed in the Component Index. Name/photo PN Used Elsewhere Function Connector-Loopback UPS 2248665 N 9-pin loopback adapter, which can be used to perform loopback tests with COM ports on the UPS, IDC and ADS Computer. Connector-Loopback Generator 2248430 N 2-pin loopback adapter, which is used solely for loopback tests on the Generator. Chapter 3 Page no. 234 Tool-Glossary.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Tools Glossary Name/photo PN Used Elsewhere Function Male Loopback - COM 5342936 N 9 pin male loopback adapter, which can be used to perform loopback tests with the (serial) COM line between the IDC and Generator Male Loopback - RT 5342937 N 9 pin male loopback adapter, which can be used to perform loopback tests with the RT line between the IDC and Generator Female Loopback - COM 5342935 N 9 pin female loopback adapter, which can be used to perform loopback tests with the (serial) COM line between the IDC and Generator Female Loopback - RT 5315956 N 9 pin female loopback adapter, which can be used to perform loopback tests with the RT line between the IDC and Generator Adapter-Loopback Sub D 9F/25Mr 2198175-2 N 9-pin to 25-pin adapter. FO Loopback Connector - SC 5260771 N Optical fiber loopback cable with SCtype optical connectors. Wall Connector (2x optical fiber) 2231528 N Wall Connector Optical Fiber 2255935 N FO Loopback Connector - LC 5260765 N Page no. 235 Tool-Glossary.fm Optical fiber loopback cable. Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Tools Glossary 3. CONSUMABLE SUPPLIES This section describes the consumable supplies which can assist with the maintenance of the Senographe system. Supplies PN Orderable How supplied Silicone Tube Lubricant (stick for the HV plug) 2344420 Y FE supply C333633 or 2344420 Y FE supply C158117 Y FE supply 46-194427P85 Y FE supply 5212483 Y FE supply N FE supply HV block, equipped kV/mA HV Grease HV Oil (Z30118) (available in 30-liter tin only) Lubricant Grease (for Lift and Rotation) Roll of adhesive tape Blank DOS formatted Extra HD 3.5" 4 MB floppy disk 45558533 Y 10CDQ80NXSL Y Initially with the Control Station Coolant kit, including: - Pre-mixed coolant for conditioner. This is provided in two containers; marked Flushing and Topping. Their contents are identical, the labeling is only for convenience of use. - Funnel. - Safety goggles. - Empty container labeled Empty. - Gloves. - Documentation. 2355459 Y FE supply Universal Fastening Kit, including various screws, allen screws, washers, nuts and caps, which can be used within the Gantry. 5343313 Y FE supply X-ray Detector Coolant 2369908 Y FE supply Blank CD-R (Box of 10) Supplies Thread Locking Compound (Blue Loctite 243) Chapter 3 Page no. 236 Tool-Glossary.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Tools Glossary Supplies Thread Locking Compound Loctite 222 Thread Locking Compound Loctite 270 Loctite Cleaner (7061) Page no. 237 Tool-Glossary.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Tools Glossary This page is blank. Chapter 3 Page no. 238 Tool-Glossary.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Central Listing Central Listing 1. Chapter 3 INTRODUCTION The Central Listing section assists in finding information on components, whether for action (e.g., switches and fuses) or for monitoring (e.g., LED indicators). It lists fuses, jumpers, switches, circuit breakers, and indicator lights, and indicates their location, their function and their normal setting. Links are provided to the appropriate component references in the FRU/Component Index on page 145, and links are provided to this section from the FRU/Component Index. 2. GENERATOR CABINET JUMPERS AND SWITCHES The information in this Section is provided only to allow verification of the position of jumpers and switches if necessary. They are normally factory-set. Jumpers and switches are divided into three groups: Generator, Mains Distribution Rack, and Gantry. Page no. 239 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-1. Generator CPU Board 400PL3 P2 P1 B1 TP43 TP2 TP50 TP8 TP27 TP103 TP110 S2 TP109 DS11 DS10 DS9 DS8 DS7 DS6 DS5 DS4 DS3 DS2 DS1 S1 TP1 TP74 TP9 X2 TP60 TP28 TP112 TP111 2-1-1. 2-1-2. 2-1-3. Generator CPU Board 400PL3 Connectors Connector Function P1 To the XP1 connector on the Generator Interface Board 400PL2 P2 To the XP2 connector on the Generator Interface Board 400PL2 Generator CPU Board 400PL3 Push Buttons Switch Function S1 Abort S2 Reset Jumper Function X1 Not Applicable X2 Battery Disconnection (see below) Jumpers Chapter 3 Page no. 240 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 1. Check (visually, do not remove it!) that the jumper on the Generator CPU board 400PL3 is installed in position X2 as shown below: • Board-CPU Generator 400PL3; see component index page 179 . B46 B41 X2 P1 BT1 P2 CAUTION This jumper must never be removed from position X2 and must never be placed in position TP1. If this jumper is either removed or placed in position TP1, the generator CPU RAMs are erased, necessitating a TOTAL RE-CALIBRATION of the generator and AEC. Page no. 241 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-1-4. Generator CPU Board 400PL3 LEDs LED Function Color DS1 Test OK Green Behavior Normal status: ON ON when the Generator CPU Board has undertaken its self-test successfully and is operating normally. OFF when the Generator CPU Board has failed its self-test and is not operating normally. DS2 Tx TTL B1 Yellow DS3 Rx D B1 Yellow DS4 Tx TTL A2 Yellow DS5 Rx D A1 Yellow DS6 Tx TTL A2 Yellow DS7 Rx D A2 Yellow DS8 Tx TTL B2 Yellow DS9 Rx D B2 Yellow DS10 Halt Red Communication signals Normal status: ON/OFF/Blinking ON/Blinking when the Generator CPU board is sending/receiving communication data. OFF when the Generator CPU board is not sending/receiving communication data. Normal status: OFF ON when the Generator CPU Board is in the halt state. OFF when the Generator CPU Board is operating normally. DS11 Reset Red Normal status: OFF ON when the Generator CPU Board is being reset. OFF when the Generator CPU Board is operating normally. 2-1-5. Generator CPU Board 400PL3 B1 Switches Chapter 3 Switch Function Default Position 1 N.C Open 2 N.C Open 3 IN5 Open 4 IN4 Open 5 IN3 Open 6 IN2 Open 7 IN1 Open 8 IN0 Closed Page no. 242 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-1-6. Generator CPU Board 400PL3 Test Points Test Point Label (in French) TP1 Gnd TP2 LDS TP3 CS_DUART TP4 UDS TP5 IRQ_DUART1 TP6 IRQ_DUART2 TP7 VPA_G64 TP8 VPA_G64 TP9 ADDR (23:00) TP10 ADDR (23:00) TP11 ADDR (23:00) TP12 ADDR (23:00) TP13 Abort TP14 Gnd TP15 Gnd TP16 Vcc TP17 Vcc TP18 CS_Banc_1 TP19 CS_Banc_0 TP20 Taille_1M TP21 CS_Blanc_3 TP22 CS_Blanc_2 TP23 Dateur TP24 ADDR (23:00) TP25 ADDR (23:00) TP26 ADDR (23:00) TP27 AS TP28 E TP29 VPA_CPU TP30 VMA_CPU TP31 FC 2 TP32 FC 1 TP33 IDL 0 TP34 IDL 1 TP35 FC 0 TP36 IDL2 TP37 DTACK TP38 IRQ4_G96 Page no. 243 Indicators and Switches.fm Function (in English) Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing Chapter 3 TP39 FIRQ_G64 TP40 CLK_16 MHz TP41 CLK_8 MHz TP42 NMI_G64 TP43 IRQ_G64 TP44 to TP109 PLCC Outputs TP110 Vcc TP111 Gnd TP112 Alim SAVV +5 V Page no. 244 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-2. Generator Interface Board 400PL2 XP1 XP2 PT3 XJ4 XJ1 PT5 PT6 PT1 TP1 TP24 PT7 TP10 TP33 XJ2 PT2 PT4 F6 TP34 TP11 TP23 DS14 DS13 DS12 DS11 DS9 DS10 DS8 DS7 DS6 DS5 DS4 DS3 DS1 TP55 DS2 H6 XJ6 XJ7 XJ8 XJ9 DS15 TP53 XJ10 2-2-1. XJ11 Generator Interface Board 400PL2 Connectors Connector Function XP1 To the P1 connector on the Generator CPU Board 400PL3 XP2 To the P2 connector on the Generator CPU Board 400PL3 XJ1 To the XJ9 connector on the Generator Command Board 400PL1 (power supply ±12 V, +5 V) XJ2 To the XJ10 connector on the Generator Command Board 400PL1 (control signals) XJ3 Not Applicable XJ4 To ADS Workstation (RS-232 communications link) XJ5 Not Applicable XJ6 To PL104 (optical fiber serial link Rx) XJ7 To PL104 (optical fiber serial link Tx) Page no. 245 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing XJ8 To PL104 (optical fiber PM) XJ9 To PL104 (optical fiber, grid sync) XJ10 To ADS UPS XJ11 To MDR 2-2-2. Generator Interface Board 400PL2 H Counters Counter Function H6 Even Compt F6 Vcc 2-2-3. Generator Interface Board 400PL2 LEDs LED Function Color DS1 kV Empty (during testing: kV applied, no mA applied) Yellow Normally OFF ON during use of proprietary maintenance menu when only kV is applied but no mA is applied. DS2 X-ray Exposure Yellow ON when an X-ray exposure is taking place. OFF when an X-ray exposure is not taking place. DS3 Polar Working Yellow ON when polarization is applied (e.g. either during an X-ray exposure or via the use of the proprietary maintenance menu). OFF when no polarization is applied. DS4 Heater Working Yellow ON when current is applied to the heater (e.g. either during a preparation and an X-ray exposure or via the use of the proprietary maintenance menu). OFF when no current is applied to the heater. DS5 Track 2 (Track 2 = Rh) Yellow ON when the Rh track from the anode is selected. OFF when the Mo track from the anode is not selected. DS6 Starter Working Yellow ON when the starter motor is rotating during a preparation. OFF when the starter motor is rotating (i.e. during times other than the preparation phase). DS7 Normal Anode Rotation Speed Yellow ON when the anode in the X-ray Tube is rotating at a normal speed. OFF when the anode in the X-ray Tube is not rotating at a normal speed. DS8 Brake Yellow ON when the anode brake in the X-ray Tube is active. OFF when the anode brake in the X-ray Tube is not active. Chapter 3 Behavior Page no. 246 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing DS9 Anode Rotation Speed at 5000 RPM Yellow ON when the anode in the X-ray Tube is rotating at a speed of 5000 RPM or above. OFF when the anode in the X-ray Tube is not rotating at a speed 5000 RPM or above. DS10 Exposure Button Green ON when the X-ray Exposure button has been pressed on the X-ray Console. OFF when in standby DS11 Prep Button Green ON when the Preperation button has been pressed on the X-ray Console. OFF when in standby DS12 -12 V Present Green ON when the -12 V from the Generator Command Board 400PL1 is present and functioning as expected. OFF when the -12 V from the Generator Command Board 400PL1 is not present. In this case, check the status of the green DS11 LED on the Generator Command Board 400PL1. • If the DS11 LED on the Generator Command Board 400PL1 is ON, change the cable between the XJ9 connector on the Generator Command Board 400PL1 and the XJ1 connector on the Generator Interface Board 400PL2. • If the DS11 LED on the Generator Command Board 400PL1 is OFF, follow the appropriate trouble shooting steps for that LED as described in Mains Distribution Board 200PL1 LEDs on page 264. DS13 +5 V Vcc Present Green ON when the +5 V from the Generator Command Board 400PL1 is present and functioning as expected. OFF when the +5 V from the Generator Command Board 400PL1 is not present. In this case, check the status of the green DS6 LED on the Generator Command Board 400PL1. • If the DS6 LED on the Generator Command Board 400PL1 is ON, change the cable between the XJ9 connector on the Generator Command Board 400PL1 and the XJ1 connector on the Generator Interface Board 400PL2. • If the DS6 LED on the Generator Command Board 400PL1 is OFF, follow the appropriate trouble shooting steps for that LED as described in Mains Distribution Board 200PL1 LEDs on page 264. Page no. 247 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing DS14 +12 V Present Green ON when the +12 V from the Generator Command Board 400PL1 is present and functioning as expected. OFF when the +12 V from the Generator Command Board 400PL1 is not present. In this case, check the status of the green DS9 LED on the Generator Command Board 400PL1. • If the DS9 LED on the Generator Command Board 400PL1 is ON, change the cable between the XJ9 connector on the Generator Command Board 400PL1 and the XJ1 connector on the Generator Interface Board 400PL2. • If the DS9 LED on the Generator Command Board 400PL1 is OFF, follow the appropriate trouble shooting steps for that LED as described in Mains Distribution Board 200PL1 LEDs on page 264. DS15 Chapter 3 Authorization Working Red ON when security is inhibited. OFF when X-ray Exposures is prohibited. Page no. 248 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-2-4. Generator Interface Board 400PL2 Test Points Test Point Label (in French) Function (in English) TP1 Cons_Chauf_A Requested Heater A Current TP2 Cons_Chauf_B Requested Heater B Current (Ground) TP3 T5000 5000 RPM Speed TP4 Entretien Normal Rotation Speed TP5 Marche_Lanceur Starter Working TP6 Freq_Polar Polar Frequency TP7 kV_Vide kV Empty TP8 Pose_Rx X-ray Exposure TP9 Marche_Chauf Heater Working TP10 Piste_2 Track 2 TP11 mA_Max Maximum mA TP12 kV_INF_5_B TP13 Strobe_kV_A TP14 SRI_kV_A TP15 Load_kV_A TP16 Load_kV_B TP17 Voyant_Pose_A Exposure Warning A TP18 0V_Pupitre X-ray Console 0V TP19 Button Prepare TP20 mA_A TP21 Rx + TP22 Rx - TP23 Tx - TP24 Frein Brake TP25 Alim_Puis_OK Power Supply OK TP26 Secu_RatTrap TP27 Pres_Supply Supply Present TP28 Pres_Chauf Heater Present TP29 Lect_Secu TP30 Marche_Polar Polarization Working TP31 Pres_Polar Polarization Present TP32 Pres_Rotat Rotation Present TP33 En_Pose On Exposure TP34 Secu_Bloq Blocking Security TP35 Timeout_Regul Timeout Regulation TP36 Trad TP37 mA_B TP38 Strobe_kV_B Page no. 249 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing Chapter 3 TP39 SRI_kV_B SRI_kV_B TP40 I_OND_Max TP41 TPose_Max Maximum Exposure Time TP42 Chute_kV kV Drop (fall) TP43 kV_Max Maiximum kV TP44 Arret_Def_Alim Stop_Def_Supply TP45 Voyant_Pose_B Exposure Warning B TP46 Bouton_Graphie Rx Pose Button TP47 Tx + TP49 kV_INF_S_A TP49 X-ray ON X-ray ON TP50 X-ray Autor X-ray Autorization TP51 Synchro_BRAS Arm Sync TP52 Trigger 1 ¨Preperation TP53 Trigger 2 Exposure TP54 Pres_Acceleration TP55 Pres_Lanc_Actiif PT1 Sortie_DAC Exit DAC PT2 Vcc Vcc PT3 +12 V +12 V PT4 0V 0V PT5 -12 V -12 V PT6 0V 0V PT7 Vref DAC Voltage Reference DAC Page no. 250 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-3. Generator Command Board 400PL1 XJ6 DS1 DS2 XJ2 DS3 TP4 TP1 TP2 TP3 TP6 TP9 TP5 TP10 XJ4 TP7 TP8 TP22 TP21 TP23 TP24 TP25 TP26 TP27 TP28 TP35 TP40 TP39 TP37 TP38 TP36 TP33 TP32 TP31 TP34 TP29 TP41 GND1 TP42 DS4 TP43 GND2 DS5 DS6 TP44 TP45 TP54 F2 DS9 DS11 TP49 TP48 TP50 TP52 F3 DS7 TP46 TP47 F1 XJ3 TP55 TP53 TP59 TP58 GND3 DS12 TP62 TP60 TP64 TP51 TP66 XJ7 TP63 TP68 XJ9 DS10 TP57 GND4 TP56 TP51 DS8 TP69 TP70 TP73 TP74 DS13 TP65 TP77 TP79 GND5 TP75 TP76 TP80 TP82 TP89 TP84 TP83 TP87 TP88 XJ5 TP90 TP85 XJ11 Page no. 251 Indicators and Switches.fm TP81 XJ12 TP71 TP78 TP86 XJ10 TP72 TP67 XJ8 XJ13 Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-3-1. Generator Command Board 400PL1 Connectors Connector Function XJ1 To the XJ1 connector on the Supply Command Board 200PL2 (standby power supply) XJ2 To the XJ5 connector on the Supply Command Board 200PL2 (250 V) XJ3 To the CN2 connector on the BT Power Supply 400T1 (power supply ±12 V, +5 V) XJ4 To the HV Tank (heater, bias) XJ5 To the XJ1 connector on the kVmA Board (HV Tank control) XJ6 To XJ1 the connector on the Anode Starter Board (+12 V, control signals) XJ7 To the XJ1 connector on the Inverter Board (control signals) XJ8 From X-ray Console Cable (27 V, Rx/Tx signal, PREP, and GRAPHIE signals) XJ9 To the XJ1 connector on the Generator Interface Board 400PL2 (power supply ±12 V, +5 V) XJ10 To the XJ2 connector on the Generator Interface Board 400PL2 (control signals) XJ11 Not Applicable XJ12 To the Rx button XJ13 To the XJ11 connector on the Supply Command Board 200PL2 (control signals) 2-3-2. Generator Command Board 400PL1 Fuses Fuse Specification PN 250 V, 2.5 A, Time delay 99194291 F1 F2 +5 V BT supply F3 Chapter 3 Function -12 V BT supply +12 V BT Supply Page no. 252 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-3-3. Generator Command Board 400PL1 LEDs LED Function Color DS1 Filament Cut Red Behavior Normal status: OFF ON when the filament is cut or there is a problem with the cable connected to the XJ4 connector. OFF when the filament is not cut. DS2 Power Current Hot Yellow Normal status: ON ON at the start of an exposure preparation. OFF when the filament is cut or has too much charge or there is no command to heat. DS3 Filament Over Charge Red Normal status: OFF ON when the heater current is too high or when the Generator Interface board sent a false command. OFF when the filament is operating properly. DS4 Over Intensity on Stator Red Normal status: OFF ON when the stator motor power is over intense. Due a short circuit in the stator motor or a problem at the Anode Starter board. OFF when the stator motor is operating properly. DS5 Rotation Movement Present Yellow Normal status: ON ON at the start of an exposure preparation signaling rotation of the anode. OFF when no current measured in the stator motor. In this case either the rotation command is not reached or there is an overintensity on the stator motor (see DS4), or a problem with the brake. DS6 Vcc +5 V BT Present Green Normal status: ON ON when the 5 V supply voltage is OK OFF when the 5 V supply voltage is defective. In this case, either: • the fuse F1 has blown • the cable going from the BT Power Supply 400T1 to the XJ3 connector is defective • the BT Power Supply 400 T1 is defective. Page no. 253 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing DS7 Auto BT Supply Present Green Normal status: ON ON when the +12 V BT power supply is present on the Generator Command Board. OFF when the +12 V BT power supply is not present on the Generator Command Board. If OFF and DS6, DS9 and DS11 are all OFF then there is a problem on the Generator Command board. If OFF and not all the LEDs DS6, DS9 and DS11 are all OFF then check the appropriate power source. DS8 Polarization Circuit Cut Red Normal status: OFF ON when the polarization circuit on the Generator Command board is broken. In this case check the cable from the HV Tank going to the XJ4 connector, or HV Tank itself. OFF when the polarization circuit on the Generator Command board is functioning correctly. DS9 +12 V Present Green Normal status: ON ON when the +12 V supply voltage is OK OFF when the +12 V supply voltage is defective. In this case, either: • the fuse F3 has blown • the cable going from the BT Power Supply 400T1 to the XJ3 connector is defective • the BT Power Supply 400 T1 is defective. DS10 Polarization Present Yellow Normal status: ON ON when polarization is present. OFF when polarization is not present. DS11 -12 V Present Green Normal status: ON ON when the -12 V supply voltage is OK OFF when -12 V supply voltage is defective. In this case, either: • the fuse F3 has blown • the cable going from the BT Power Supply 400T1 to the XJ3 connector is defective • the BT Power Supply 400 T1 is defective. Chapter 3 Page no. 254 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing DS12 Security Re-obtainable Red Normal status: OFF ON when the security signal has been triggered by kV max, Chute kV, mA max, or Iond max. OFF when there is no security issue. DS13 Security Blocked Red Normal status: OFF ON when the security signal has been triggered by DEF alim or DEF TRAD. OFF when there is no security issue. 2-3-4. Generator Command Board 400PL1 Jumpers Jumper Function JP1 Defines lamp behavior when the door is open/closed JP2 Defines lamp behavior when the door is open/closed JP3 Parking for unused jumpers in JP1 (see text below) JP4 Parking for unused jumpers in JP2 (see text below) 1. Check that jumpers JP1 and JP2 are installed on Generator Command Board 400PL1. They must not be installed in the parking position JP3 and JP4 at this point. See illustration below. Note: JP1 and JP2 are connected to the room relays on Generator Command Board 200PL4. Refer to Job Card PHY A018 - Room Lamps and Door Configuration on page 475 for more information. • Board-Generator Command 400PL1; see component index page 179 . XJ 10 JP3 & JP4 (parking) XJ8 Right bottom edge of board JP1 XJ13 JP2 Page no. 255 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-3-5. Generator Command Board 400PL1 Test Points Chapter 3 Test Point Label (in French) Function (in English) TP1 Surcharge_Filament Filament overload TP2 Measure_Phase_1 TP3 Measure_Phase_3 TP4 ICH_Carre RMS Health Current TP5 Consigne_ICH_Carre RMS Health Current Reference TP6 Output B13/8 TP7 Input B8 (auto_regul_ch) TP8 Measure_Phases TP9 Reset ADR TP10 C_T6 TP11 B_T6 TP12 C_T5 TP13 B_T5 TP14 C_T4 TP15 B_T4 TP16 C_T3 TP17 B_T3 TP18 C_T2 TP19 B_T2 TP20 C_T1 TP21 B_T1 TP22 Output B13/6 TP23 Clock B6 TP24 SEL_LC TP25 Auto_Regul_Ch TP26 Measure_Phase_TTL TP27 Output_B16 (ICH_OND) TP28 Fil_Coupé Filament Cut TP29 Surcharge_Detectee Overload Detected in Filament TP30 Marche_Chauffage (dealye) Heater Working (delay) TP31 Output B24/10 TP32 Presence_Chauffage Heater Presence TP33 Entretien LC Normal RPM Speed TP34 Input B38/5 TP35 5000_LC TP36 Output B35/10 TP37 Fin_Tour Tour Finish TP38 Detect_SurInt_LC Overload Current LC detected Stator Command Signals 5000 RPM Speed Page no. 256 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing TP39 125 kHz LC Clock 125 kHz TP40 Reset_Detect TP41 Reset B21/1 TP42 Under Int saved LC TP43 Brake LC TP44 Presence_Rotation TP45 H500 (clock) TP46 Vcc (+5 V) TP47 H62_5K (clock) Clock 62.5 kHz TP49 H250K (clock) Clock 250 kHz TP49 H4M (clock) Clock 4 MHz TP50 H2M (clock) Clock 2 MHz TP51 Presence_Polarisation Polarization Presence TP52 12 V BT Supply Page no. 257 Indicators and Switches.fm Rotation Presence Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing X15 X16 Inverter Board 300PL1 X14 X13 2-4. ST1 ST2 XJ1 PT1 PT3 PT2 X7 X10 PT4 PT5 X11 X12 L1 X1 X6 X2 Chapter 3 X4 X3 X9 X5 X8 Page no. 258 Indicators and Switches.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-4-1. Inverter Board 300PL1 Connectors Connector Function XJ1 To the XJ7 connector on the Generator Command Board 400PL1 (Prep, Exposure thyristor command) X1 0V/600VR X2 Not Applicable X3 415 V Monophase (1) X4 415 V Monophase (2) X5 600VR X6 300VR X7 600VF X8 HF2 X9 HF1 X10 0V/600VF X11 Thermal Switch (1) X12 Thermal Switch (2) X13 Gate/TH1 X14 K / TH1 X15 Gate/TH2 X16 K / TH2 Page no. 259 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-4-2. Inverter Board 300PL1 Neon Lights LED Function Color L1 600 V Present Clear Behavior Normal status: ON ON when the 600 V from the Mains Distribution Board 200PL1 is present. OFF when there is a problem with the 600 V from the Mains Distribution Board 200PL1. In this case, proceed as follows: Check the states of the all the LEDs on the Mains Distribution Board 200PL1(see Mains Distribution Board 200PL1 LEDs on page 264). • If the states of any of the LEDs are abnormal, fix the problem as described in Mains Distribution Board 200PL1 LEDs on page 264. • If the states of all the LEDs are normal, check with a multimeter that the voltage between the X3 and X4 connectors on the Inverter Board 300PL1 is at 415 V. If the voltage is at 415 V, change the Inverter Board 300PL1. If the voltage is not at 415 V, check the cabling between the Mains Distribution Board 200PL1 and the capacitors of the DC Bus on the Inverter Board 300PL1. 2-4-3. 2-4-4. Inverter Board 300PL1 Straps Strap Function ST1 Gate TH1 ST2 Gate TH2 Inverter Board 300PL1 Test Points Chapter 3 Test Point Label (in French) PT1 A/TH1 PT2 HF1 PT3 K/TH2 PT4 600VF PT5 0V/600VF Function (in English) 600 VF supply at 0 V Page no. 260 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-5. Anode Starter Board 300PL2 XJ1 PT1 PT11 PT2 PT4 PT3 PT9 PT6 PT5 PT12 PT7 PT10 PT13 PT8 PT17 PT14 PT15 PT16 PT19 PT20 PT21 PT24 PT22 PT18 XJ2 XJ3 PT25 PT23 2-5-1. Anode Starter Board 300PL2 Connectors Connector Function XJ1 To the XJ6 connector on the Generator Command Board 400PL1 (control signals) XJ2 To Stator (U, V, W) (power phases) XJ3 To the XJ5 connector on the Supply Command Board 200PL2 (250 V power supply) Page no. 261 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-5-2. Anode Starter Board 300PL2 Test Points Chapter 3 Test Point Label (in French) Function (in English) PT1 T1 Command PT2 Bloc T1 PT3 T2 Command PT4 Bloc T2 PT5 T3 Command PT6 Block T3 PT7 T4 Command PT8 +12 V Coupé PT9 Bloc T4 PT10 T5 Command PT11 Bloc T5 PT12 Bloc T6 PT13 T6 Command PT14 Phase 1 Phase 1 Output PT15 Phase 2 Phase 2 Output PT16 Phase 3 Phase 3 Output PT17 S/T2-T4-T6 PT18 SUR_I_B Overload Current 1 PT19 0V Phase 1 0V Phase 1 PT20 Measure Phase 1 Measure Phase1 PT21 Measure Phase 3 Measure Phase 3 PT22 +250 V +250 V Present PT23 0V/250V 250 V supply at 0V PT24 0V Phase 3 0 V Phase 3 PT25 SUR_I_H Overload Current 2 Command Signals +12 V Cut Command Signals Page no. 262 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-6. Mains Distribution Board 200PL1 XJ7 XJ8 XJ14 XJ11 XJ10 XJ12_2 XJ6 DE1 XJ5 XJ12_1 XJ13_2 XJ13_1 XJ4 PT1 N2 DE2 PT3 DE3 PT2 DE4 DE5 N1 SW2 F2 F3 PT8 PT4 PT5 PT6 PT7 SW1 PT9 0VE P1 PT10 XJ2 PT12 PT13 PT14 XJ1 PT11 DE9 DE8 XJ3 DE6 DE7 F1 IN2 PT16 PT15 PT17 PT18 P2 PT19 PT20 Page no. 263 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-6-1. Mains Distribution Board 200PL1 Connectors Connector Function XJ1 PH1 XJ2 SEL XJ3 N/PH2 XJ4 W2 XJ5 Not Applicable XJ6 300 VR XJ7 W1 XJ8 600 VF XJ9 0V (-600V) XJ10 To Relay K1 XJ11 To the XJ2 connector on the Supply Command Board 200PL2 (+12V, control/data signals) XJ12 Seno ON XJ13 X-ray ON XJ14 Seno ON/X-ray ON 2-6-2. Mains Distribution Board 200PL1 LEDs LED Function Color DE1 Attente MST Red Behavior Normal status: OFF ON when the DC Bus is below a level of 30 V. Usually ON for a few seconds after the X-ray Console ON button is pressed while the DC Bus reaches 30 V. If permanently ON, there is a problem with the DC Bus reaching 30 V. In this case, proceed as follows: • Check the status of the DC Bus indicated by yellow DE5 LED. • If the DE5 LED is ON there is a problem with the Mains Distribution Board 200PL1, and you must change it. • If the DE5 LED is OFF there is a problem with the 600 V on the Inverter Board 300PL1. Check 200PL1 XJ8 and 300PL1 X5 connectors - if the connectors are OK change 300PL1. If the DE1 LED on the Mains Distribution Board 200PL1 and the DE2 LED on the Supply Command Board 200PL2 are not the same state, change the cable between the XJ11 connector on the Mains Distribution Board 200PL1 and the XJ2 connector on the Supply Command Board 200PL2. OFF when the DC Bus is operating normally at a level of around 600 V. Chapter 3 Page no. 264 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing DE2 +12 V (+VR) Present Green Normal status: ON ON when 12 V is present (i.e. when the S1 switch between the Power Line Filter and the Mains Distribution Board 200PL1 is closed). OFF when there is a problem and no 12 V is present. In this case, proceed as follows: • Check the fuse F1. • If the fuse F1 is OK, check the fuses of the mains input. • If the fuses of the mains input are OK, check the cabling arriving on the XJ1 and XJ3 connectors. • If the cabling is OK there is a problem with the transformer TR2 or RT1. Change the Mains Distribution Board 200PL1. DE3 +12 V (+VV) Present Green Normal status: ON ON when 12 V is present (i.e. when the S1 switch between the Power Line Filter and the Mains Distribution Board 200PL1 is closed). OFF when there is a problem and no 12 V is present. In this case, proceed as follows: • Check the fuse F1. • If the fuse F1 is OK, check the fuses of the mains input. • If the fuses of the mains input are OK, check the cabling arriving on the XJ1 and XJ3 connectors. • If the cabling is OK there is a problem with the transformer TR2 or RT1. Change the Mains Distribution Board 200PL1. DE4 DC Bus Voltage Too High E > 700 V (normally DC Bus Voltage is 600 V) Red Normal status: OFF ON when the 600 V DC Bus Voltage is too high. In this case, proceed as follows: • Use a multimeter to check the voltage on the XJ9 connector. • If the measured voltage is bad (i.e. 650 V to 700 V) check the configuration of the tension on the transformer and the tension sector. • If the configuration of the tension on the transformer and the tension sector are OK there is a problem with the transformer. OFF when the DC Bus is operating normally at a level of around 600 V. Page no. 265 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing DE5 DC Bus Voltage Below 30 V E < 30 V Yellow Normal status: OFF ON briefly when the X-ray Console ON button is pressed. If permanently ON and the N1 neon light is ON there is a problem with the 600 V. In this case, check the cabling between the Inverter Board 300PL1, the capacitors of the DC Bus and the Mains Distribution Board 200PL1. OFF when the DC Bus is operating normally at a level of 30 V and above. DE6 DC Bus Below Precharge Tension Yellow E > 250 V Normal status: ON ON when the DC Bus is below the precharge tension and operating correctly. OFF when the DC Bus is not below the precharge tension and not operating correctly. In this case, proceed as follows: • Check the state of DE5. • If DE5 is ON then follow the appropriate trouble shooting described for when DE5 is ON. • If DE5 is OFF check the state of DE7. • If DE5 OK, use a multimeter to check the voltage on the XJ9 connector. The cause of the anomaly comes from the Inverter Board 300PL1, configuration of the Transformer or the Transformer itself. If the voltage (tension) measured does not correspond with the indication of the LEDs, the problem comes from the comparators on the board and you must change the Mains Distribution Board 200PL1. DE7 DC Bus Voltage Too Low E < 400 V Red Normal status: OFF ON when the 600 V DC Bus Voltage is too low. In this case, proceed as follows: • Use a multimeter to check the voltage on the XJ9 connector. • If the measured voltage is bad (i.e. less than 550 V) check the configuration of the tension on the transformer and the tension sector. • If the configuration of the tension on the transformer and the tension sector are OK there is a problem with the transformer. OFF when the DC Bus is operating normally at a level of around 600 V. Chapter 3 Page no. 266 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing DE8 -8 V (-VE) Green Normal status: ON ON when -8 V is present (i.e. when the S1 switch between the Power Line Filter and the Mains Distribution Board 200PL1 is closed). OFF when there is a problem and no -8V is present. In this case, proceed as follows: • Check the fuse F2. • If the fuse F2 is OK, check the fuses at the mains input. • If the fuses at the mains input are OK, check the cabling arriving on the XJ1 and XJ3 connectors. • If the cabling is OK there is a problem with the transformer TR2 or RT4. Change the Mains Distribution Board 200PL1. DE9 +8 V (+VE) Green Normal status: ON ON when +8 V is present (i.e. when the S1 switch between the Power Line Filter and the Mains Distribution Board 200PL1 is closed). OFF when there is a problem and no +8 V is present. In this case, proceed as follows: • Check the fuse F3. • If the fuse F3 is OK, check the fuses at the mains input. • If the fuses at the mains input are OK, check the cabling arriving on the XJ1 and XJ3 connectors. • If the cabling is OK there is a problem with the transformer TR2 or RT3. Change the Mains Distribution Board 200PL1. Page no. 267 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-6-3. Mains Distribution Board 200PL1 Neon Lights LED Function Color N1 Power Present Orange Behavior Normal status: ON ON when power from the Generator Transformer is present. OFF when power from the Generator Transformer is not present. In this case check the status of the N2 neon light. N2 K1 under tension Orange Normal status: ON ON when the K1 contact is under tension. OFF when the K1 contact is not under tension. In this case, proceed as follows: • Check the X2 relay on the Mains Distribution Board 200PL1. • If the X2 relay is okay, check that the tension selector (SEL) is on the correct value. • If the X2 relay and the tension selector are OK, check the upstream fuses at the mains input. 2-6-4. Mains Distribution Board 200PL1 Fuses Fuse Specification PN Function F1 250 Vac, 1 A, Delay 58079686 1 A/250 V (+8 V) F2 250 Vac, 0.5 A, Delay 58079685 0.5 A/250 V (-8 V) F3 2-6-5. 2-6-6. 2-6-7. 0.5 A/250 V (+12 V) Mains Distribution Board 200PL1 Potentiometers Strap Function P1 Threshold E_Sup_EMax_a P2 Threshold E_Sup_EMin_a Mains Distribution Board 200PL1 Straps Strap Function IN1 Not Applicable IN2 BT Power Selector. Must be on left-hand side in the BT position. Mains Distribution Board 200PL1 Switches Chapter 3 Strap Function SW1 Test measure E SW2 Test measure E Page no. 268 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-6-8. Mains Distribution Board 200PL1 Test Points Test Point Label (in French) Function (in English) PT1 +12 V (+VR) +12 V Permanent PT2 0VV 0V PT3 +12 V (+VV) +12 V Premanent PT4 E_Sup_Emax Info DC Bus > 700 V PT5 E_Sup_EPRE Info DC Bus > 250 V PT6 E_Sup_30V Info DC Bus > 30 V PT7 E_Sup_Emin Info DC Bus > 400 V PT8 +VE +VE (+8 V) PT9 -VE -VE (-8 V) PT10 Ref 400 V Reference 400 V (Min threshold) PT11 Ref 250 V Reference 250 V (Precharge) PT12 0 V (0 VE) 0V PT13 MES_E_B (0 V) DC Bus Measure 1 PT14 -8 V (-VE) -8 V (internal for 200PL1) PT15 +8 V (+VE) +8 V (internal for 200PL1) PT16 Ref 30 V Reference 30 V (DC Bus Detection) PT17 +5 V +5 V PT18 MES_E_a (600 V) DC Bus Measure 2 PT19 Ref 700 V Reference 700 V (Max threshold) PT20 B2 Output DC Bus Measure Voltage 0VE 0 VE 0V Page no. 269 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-7. Supply Command Board 200PL2 XJ3 F1 XJ4 F3 TP1 XJ9 XJ8 F2 0VV TP4 TP9 F6 TP5 XJ3 XJ1 TP2 TP3 TP6 TP7 TP8 TP10 TP12 XJ10 TP13 XJ6 TP15 P250V P27V XJ7 0V/27V XJ2 TP16 TP19 TP18 0V/250V TP19 F5 XJ5 TP21 F4 TP19 2-7-1. Supply Command Board 200PL2 Connectors Connector Function XJ1 To the XJ1 connector on the Generator Command Board 400PL1 (standby power supply) XJ2 To/from the XJ11 connector on the Mains Distribution Board 200PL1 (12 V, control/data signals) XJ3 Fan (+27 V) XJ4 To the XJ4 connector on the Relay Board 200PL4 (control/data signals) XJ5 To the XJ2 connector on the Generator Command Board 400PL1 (0, +250 V DC) To the CN1 connector on the BT Power Supply (0, +250 V DC) To the XJ3 connector on the Anode Starter Board 300PL2 (0, +250 V DC) XJ6 + 27 V on the C1 capacitor in the Generator XJ7 0 V on the C1 capacitor in the Generator XJ8 Thermostat (+27 V) XJ9 To auto transformer (250 V) XJ10 To emergency stop button on Gantry and thermal switch the Auto Transformer (security signal) XJ11 To the XJ13 connector on the Generator Command Board 400PL1 (control signals) Chapter 3 Page no. 270 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-7-2. Supply Command Board 200PL2 LEDs LED Function Color DE1 Standby 12 V present via the XJ2 connector Green Behavior Normal status: ON ON when the standby 12 V from the Mains Distribution Board 200PL1 is present. OFF when there is a problem with the standby 12 V from the Mains Distribution Board 200PL1. In this case, proceed as follows: • Check the status of the 12 V on the Mains Distribution Board 200PL1 indicated by its green DE2 LED. • If the 12 V is OK on the Mains Distribution Board 200PL1, check the cable between the XJ2 connector and the XJ11 connector on the Mains Distribution Board. • If the cable is OK, check the fuses at the mains supply. • If the fuses at the mains supply are OK change the Mains Distribution Board 200PL1. DE2 Waiting for Power On Red Normal status: OFF ON when the DC Bus is below a level of 30 V. Usually ON for a few seconds after the X-ray Console ON button is pressed while the DC Bus reaches 30 V. If permanently ON, there is a problem with the DC Bus reaching 30 V. In this case, proceed as follows: • Check the status of the DC Bus on the Mains Distribution Board 200PL1 indicated by its yellow DE5 LED. • If the DE5 LED is ON there is a problem with the Mains Distribution Board 200PL1, and you must change it. • If the DE5 LED is OFF there is a problem with the 600 V on the Inverter Board 300PL1. Check 200PL1 XJ8 and 300PL1 X5 connectors - if the connectors are OK change 300PL1. OFF when the DC Bus is operating normally at a level of around 600 V. Page no. 271 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing DE3 Heater Meter at Maximum Limit Red Normal status: OFF ON when the heater meter has reached the maximum value. This is normal after some important stop/starts. In this case cut the power to the Generator and power it back up. If the DE3 LED systematically is on after restarting the Generator, replace the Supply Command Board 200PL2. OFF when the heater meter is operating normally and has not reached its maximum limit. 2-7-3. Supply Command Board 200PL2 Neon Lights LED Function Color N1 250 V from the Transformer present Orange Behavior Normal status: ON ON when the 250 V supply from the Generator Transformer is present. OFF when 250 V supply from the Generator Transformer is not present. In this case, proceed as follows: • Check the F6 fuse, and change if necessary. • Check the status of the N1 and N2 neon lights on the Mains Distribution Board 200PL1. If N1 and N2 are ON there is a problem with either the Generator Transformer or the cabling of the Generator Transformer. Check the cabling within the Generator Transformer and on the K1 contact and XJ10 connector. If N1 is OFF and N2 is ON there is possibly a problem with the X1 relay on the Mains Distribution Board 200PL1, and you must change the Mains Distribution Board 200PL1. 2-7-4. Supply Command Board 200PL2 Fuses Fuse Specification PN Function F1 250 Vac, 3.15 A, Delay 99194288 3.15 A / 250 V (+27 V X-ray Console) F2 250 Vac, 0.5 A, Delay 58079685 0.5 A / 250 V +27 V fan) F3 150 Vac, 125 A, Fast 91684676 125 A/150 V (27 V AC) F4 380 Vac, 10 A, Fast 58079166 10 A/380 V (starter, 250 V) F5 F6 Chapter 3 10 A/380 V (heater, BT supply, 250 V) 250 Vac, 16 A, Fast 58079690 16 A/250 V (250 V AC) Page no. 272 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-7-5. Supply Command Board 200PL2 Test Points Test Point Label (in French) Function (in English) PT1 Inib Decomptage Inhibit counting B11 PT2 Contact K2 K2 Contact PT3 Alim Puissance OK Power Supply OK PT4 Pres. Alim Supply Present PT5 250 V < E < 700 V 250 V < E < 700 V PT6 Cde Contacteur K1 Power Switch Command PT7 MST Power ON PT8 Teta_Sup_Tmax Overtemperature PT9 RAZ 3 s Reset Counter B11 PT10 Demande MST Power ON Request PT11 T_Sup_3S Delay > 3 s PT12 7.63 Hz 7.63 Hz Clock PT13 Echauffement Clock Counter B8 PT14 Auto MST Automatic Power ON Signal PT15 B13 Output B13 Counter Outpuy PT16 15.6 kHz Clock 15.6 kHz Clock PT17 Contacteur K1 Switch Command PT18 +VLC (+12 V) +12 V PT19 Cde Precharge Precharge DC Bus Command PT20 Threshold pres acceleration + 174 mV DC Voltage PT21 Threshold lanceur actif +20 mV DC Voltage P250V +250 V +250 V present P27V +27 V +27 V present 0V/250V 0 V (250 V) Ground for 250 V supply 0V/27V 0 V (27 V) Ground for 27 V supply Page no. 273 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-8. Relay Board 200PL4 XJ1 XJ4 XJ2 XJ3 2-8-1. Relay Board 200PL4 Connectors Connector Function XJ1 X-ray Room Lamp Indicator Cable - Senographe System ON XJ2 X-ray Room Lamp Indicator Cable - X-ray ON XJ3 X-ray Room Lamp Indicator Cable - Room Door XJ4 To the XJ4 connector on the Supply Command Board 200PL2 (control signals) Chapter 3 Page no. 274 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-9. kVmA Board 7001PL1 MES_MA_POS MES_MA_NG TP2 TP22 TP3 SW1 P5 TP16 SW2 XJ2 DS2 DS1 TP13 TP8 TP14 TP25 TP27 TP5 TP20 TP1 TP7 P2 TP29 TP31 TP9 TP21 TP30 TP24 TP26 TP15 TP18 TP12 XJ3 P1 TP28 TP11 XJ4 TP4 TP6 P3 TP17 TP19 DS3 TP10 TP23 XJ1 2-9-1. kVmA Board 700PL1 Connectors Connector Function XJ1 To XJ5 connector on Generator Command Board 400PL1 (HV Tank control) XJ2 To HV Tank (mA feedback) XJ3 To HV Tank (kV measure) XJ4 Test 62 kV (testing input) Page no. 275 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-9-2. kVmA Board 700PL1 LEDs LED Function Color DS1 -15 V Present Green Behavior Normal status: ON ON when the -15V from the Generator Command Board 400PL1 is present. OFF when there is a problem with the -15V from the Generator Command Board 400PL1. In this case, proceed as follows: • Check the status of the 12 V on the Generator Command Board 400PL1 indicated by its green DS9 LED. If the DS9 LED is ON, change the cable between the XJ1 connector on the kVmA Board and the XJ5 connector on the Generator Command Board 400PL1. • If the problem persists, change the HV Tank. DS2 +15 V Present Green Normal status: ON ON when the +15 V from the Generator Command Board 400PL1 is present. OFF when there is a problem with the +15 V from the Generator Command Board 400PL1. In this case, proceed as follows: • Check the status of the 12 V on the Generator Command Board 400PL1 indicated by its green DS9 LED. If the DS9 LED is ON, change the cable between the XJ1 connector on the kVmA Board and the XJ5 connector on the Generator Command Board 400PL1. • If the problem persists, change the HV Tank. Chapter 3 Page no. 276 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing DS3 - 12 V Present Green Normal status: ON ON when the -12 V from the Generator Command Board 400PL1 is present. OFF when there is a problem with the -12 V from the Generator Command Board 400PL1. In this case, proceed as follows: • Check the status of the -12 V on the Generator Command Board 400PL1 indicated by its green DS11 LED. If the DS11 LED is ON, change the cable between the XJ1 connector on the kVmA Board and the XJ5 connector on the Generator Command Board 400PL1. If the DS11 LED is OFF, check whether the -12 V returns when you disconnect the cable between the XJ1 connector on the kVmA Board and the XJ5 connector on the Generator Command Board 400PL1. If the problem persists (i.e. DS11 is still OFF), change the Generator Command Board 400PL1. 2-9-3. kVmA Board 700PL1 Switches Switch Function SW1 Test 120 mA SW2 Test 50 mA 2-9-4. kVmA Board 700PL1 Potentiometer Switch Function P1 kV gain input (1) P2 kV gain input (2) P3 Vref B1 adjust P4 Not Applicable P5 Measure mA adjust Page no. 277 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 2-9-5. kVmA Board 700PL1 Test Points Test Point Label (in French) Function (in English) TP1 0VK 0V TP2 0VM 0V TP3 Retour_MA mA feedback (or return) TP4 Vcc Vcc (+5 V) TP5 Chute_kV kV < Minimum Threshold TP6 -10 V TP7 Measure_kV TP8 kV_Ref TP9 E kV TP10 kV_Ref_Auto kV Reference Automatic TP11 kV_Ref_Manuel kV Reference Manual TP12 Init 1 TP13 kV 2 TP14 kV 1 TP15 Init 2 TP16 Measure mA TP17 N.C TP18 N.C TP19 N.C TP20 Auto Regul TP21 kV 5 TP22 Ref_mA_Max TP23 -12V_Drivers TP24 N.C TP25 kV C TP26 N.C TP27 kV X TP28 N.C TP29 Ref kV X TP30 mA Max TP31 mA_F kV Reference kV at 5 kV kV Max Reference kV Max 2-10. Mains Distribution Rack Jumpers and Switches • Check that the jumpers on the Mains Distribution Board are installed as follows: Chapter 3 Jumper Present? Where? TP1 NO Between K2 and K6 TP2 NO Beside K8 TP3 YES Beside K10 Page no. 278 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 3. GENERATOR CABINET CIRCUIT BREAKERS MDR Breaker Conditioner and MDR Conditioner Button Detector Supply Button Control Station Button UPS Button Generator Generator Breaker The power control buttons on the top of the Generator allow you to power on/off each of the labeled components, so that you can isolate them as required. Except for the UPS push-button, the other push-buttons contain a second indicator light to the right-hand side of the push-button, and function as follows: • the left-hand side push button toggles on/off the power to/from the component • when power is applied to the component the left-hand side push-button is illuminated green and the right-hand side light is not illuminated • when power is not applied to the component the right-hand side light is illuminated yellow indicating that the component is in standby, and the left-hand side push button is not illuminated The UPS indicator light is off during normal operation when the system is powered up, during which time it is charging. If the mains AC supply power to the Senographe system is suddenly cut, the UPS supplies power to the Control Station components for a few minutes. During this time, the UPS indicator light is illuminated. Page no. 279 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing The on/off power buttons on the X-ray Console override the power states of each component. For example, if you power off/on the system from the X-ray Console, the states of the power to each of the component defaults as indicated below. Push button Component controlled Default status when X-ray Console ON button supplies power to the system Default status when X-ray Console OFF button cuts power to the system Conditioner Conditioner ON ON Detector Power Supply Detector Power Supply ON ON Cart UPS in Control Station (supplies power to entire Control Station) ON OFF The table above assumes that the mains AC power supply is connected to the Generator, and the Generator/MDR breakers are switched on. Chapter 3 Page no. 280 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 3-1. Mains Distribution Assembly F1 J3 DS1 DS2 J4 J1 DS3 F2 TP1 DS4 DS5 J5 DS6 DS7 F5 F4 J2 F3 DS8 TP3 TP2 J8 J6 J7 DS9 J9 3-1-1. Mains Distribution Assembly Connectors Connector Function J1 240 V Supply from Primary Transformer J2 240 V Supply to Conditioner J3 230 V Supply from Secondary Transformer J4 230 V AC supply to Control Station UPS via 250 V Line Filter, XP4 connector on Conditioner Cabinet and XJ2 connector on Gantry bulkhead J5 AC supply to J1 connector on Detector Power Supply via XP5 connector on Conditioner Cabinet J6 220 V to the IN connector on the Low Voltage Power Supply Board J7 12 V from the OUT connector on the Low Voltage Power Supply Board J8 FFDM Mains Distribution connection to XJ11 connector on Generator Interface Board 400PL2 J9 Data connection to the Service Interface (Condioner, Control Station and UPS power control buttons) on the Generator Page no. 281 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 3-1-2. Mains Distribution Assembly LEDs LED Function Color DS1 240 V from Primary Transformer Clear Behavior Normal status: ON ON when the 240 V Supply from the Primary Transformer is present. OFF when there is a problem with 240 V Supply from the Primary Transformer. DS2 230 V ADS Clear Normal status: ON ON when the 230 V AC supply to the Control Station UPS is present. OFF when there is a problem with the 230 V AC supply to the Control Station UPS. DS3 230 V from Primary Transformer Clear Normal status: ON ON when the 230 V Supply from the Secondary Transformer is present. OFF when there is a problem with 230 V Supply from the Secondary Transformer. DS4 230 V DPS (APS_SPS) Clear Normal status: ON ON when the 230 V AC supply to the Detector Power Supply is present. OFF when there is a problem with the 230 V AC supply to the Detector Power Supply. DS5 Power ON ADS Orange Normal status: ON/OFF ON when the ADS is powered on via the Control Station power button on the Service Interface. OFF when the ADS is powered off via the Control Station power button on the Service Interface. DS6 Power ON DPS (APS_SPS) Orange Normal status: ON/OFF ON when the Detector Power Supply is powered ON. OFF when the Detector Power Supply is powered OFF. DS7 Power ON Condtioner Orange Normal status: ON/OFF ON when the Conditioner is powered ON. OFF when the Conditioner is powered OFF. Chapter 3 Page no. 282 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing DS8 230 V to Conditioner Clear Normal status: ON/OFF ON when the 230 V Supply going to the Conditioner is present. OFF when there is no 230 V Supply going to the Conditioner. DS9 Standby 12 V present via the Out connector on the Low Voltage Power Supply board Green Normal status: ON ON when the standby 12 V from the Low Voltage Power Supply Board is present. OFF when there is a problem with the standby 12 V from the Low Voltage Power Supply board. In this case, proceed as follows: • Check the F3 and F5 fuses on the Mains Distribution Assembly, and change them if necessary. • If F3/F5 fuses are OK, check the F2 fuse on the Low Voltage Power Supply Board, and change if necessary. • If the F2 fuse is okay, check the cable between the XJ7 connector and the OUT connector on the Low Voltage Power Supply Board. • If the cable connection and F2 fuse on the Low Voltage Power Supply Board are OK, change the Low Voltage Power Supply Board. Page no. 283 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 3-1-3. Mains Distribution Assembly Configuration Jumpers Jumper Default Setting TP1 OFF (Open) Control Station Power OFF function. If TP1 is OFF (as required), the Control Station cannot • cannot be powered off by the Generator Control Buttons • cannot be powered off by the X-ray Console Power button • it is powered off by the ADS shutdown process TP2 OFF (Open) Conditioner auto power off enabled. If the TP2 jumper is OFF (as required), the Conditioner is always ON even when the Generator is powered OFF. TP3 ON (Closed) 3-1-4. Function DPS auto power off enabled. If TP3 is ON (as required), the DPS is switched OFF by system. Mains Distribution Assembly Fuses Fuse Specification PN Function F1 250 Vac, 10 A, Delay 99183979 Power Supply (XP4) to Control Station (UPS) F2 250 Vac, 5 A, Delay 99183923 Power Supply (XP5) to Detector Power Supply input F4 Line Power Voltage Input to Conditioner (J2 - LED DS8) F3 250 Vac, 1.6 A, Delay 99183925 Power Supply to Low Voltage Power Supply input F5 250 Vac, 1.0 A, Delay 99183936 + 12V from Low Voltage Power Supply Chapter 3 Page no. 284 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 3-2 Low Voltage Power Supply IN F1 OUT 3-2-1. Low Voltage Power Supply Connectors Connector Function IN 240 V Supply from Primary Transformer OUT 240 V Supply to Conditioner 3-2-2. Low Voltage Power Supply Fuses Fuse Specification PN Function F1 220 Vdc, 2.5 A, Fast N/A AC input LVPS protection Note: The F1 Fuse on the Low Voltage Power Supply cannot be changed. If the F1 fuse is faulty you must change the Low Voltage Power Supply Board. Page no. 285 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 4. GANTRY BOARD INDICATORS AND FUSES 4-1. DC Boards • • Board-Lift DC PL201; see component index page 158 . Board-Rotation PL202; see component index page 158 . J1 K1 J12 J7 DS4 J6 J8 DS6 DS1 DS2 J10 J15 DS5 J2 DS3 DS7 DS13 J13 DS14 U10 J22 J11 DS8 J23 J19 J4 DS9 J21 J5 DS10 DS12 J18 J16 Chapter 3 DS11 J17 J3 J14 J9 Page no. 286 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing The Lift DC Board PL201 and the Rotation DC Board PL202 are different boards located in different places within the Senographe system. They have similar layout as shown above and indicators as shown in the table below. LED Function Color Behavior DS1 15 V Green ON when the 15 V supply voltage is OK OFF when the 15 V supply voltage is defective DS2 3,3 V Green ON when the 3.3 V supply voltage is OK OFF when the 3.3 V supply voltage is defective DS3 5V Green ON when the 5 V supply voltage is OK OFF when the 5 V supply voltage is defective DS4 48 V Power applied on H-Bridge Red DS5 Rotation Brake Command (does not exist for lift board or not used by lift board) Green ON when the rotation brake is inactive (rotation movement is enabled) OFF when the rotation brake is active (rotation movement is not enabled) DS6 Clutch Command (does not exist for lift board) Green ON when the clutch is inactive (Angulation movement is enabled) OFF when the clutch is active (Angulation movement is not enabled) DS7 Microcontroller activity Green Blink fast = node not initialized Blink slow = OK Light ON = CAN activity DS8 Verifies whether power is effectively applied to the motor when a movement command has been requested. Red ON when 48 V DC is applied on the H-Bridge OFF when 48 V DC is not applied on the H-Bridge OFF if a movement command is sent from the MOS drive and power is effectively applied to the motor. ON if no movement command is sent from the MOS drive and no power is effectively applied to the motor, or if there is a faulty H-Bridge. DS9 RT2 Grid Synchro Yellow DS10 CAN Bus activity Yellow ON or OFF when CAN Bus activity occurs. DS11 Not Used Yellow N/A DS12 RT1 valid Line Yellow ON when the valid line is active (movement is enabled) OFF when the valid line is inactive (movement is not enabled) DS13 DSP Live Green Blinks fast when the DSP is alive, representing the heartbeat of the DSP. OFF when the DSP is dead. DS14 3.3 VA Green ON when the 3.3 VA analog supply voltage is OK OFF when the 3.3 VA analog supply voltage is defective The diodes DS4 and DS8 are associated with lift/rotation movement. For more information, refer to Job Card DIAG A010 - No Lift or Rotation Movement on page 1005. Page no. 287 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 4-2. • • Stepper Board Board-Compression PL303; see component index page 157 . Board-Tilt PL401; see component index page 158 . J7 J6 J10 J1 DS1 DS5 F1 DS2 DS4 DS3 DS6 DS8 DS7 J21 J5 J22 DS9 J2 F2 DS10 J3 J11 J12 F3 J8 J4 J9 LED Function Color DS1 48 V Green ON when the 48 V DC supply voltage is OK OFF when the 48 V DC supply voltage is defective DS2 3,3 VA Green ON when the 3.3 VA analog supply voltage is OK OFF when the 3.3 VA analog supply voltage is defective DS3 Synchro Grid Yellow DS4 Not Used Yellow N/A DS5 5V Green ON when the 5 V supply voltage is OK OFF when the 5 V supply voltage is defective DS6 RT1 Valid Line Yellow ON when the valid line is active (movement is enabled) OFF when the valid line is inactive (movement is not enabled) DS7 Compression Brake Actived (does not exist for tilt board) Green ON when the rotation brake is inactive (rotation movement is enabled) OFF when the rotation brake is active (rotation movement is not enabled) DS8 RX-CAN Yellow ON when CAN data (or command) received. OFF when no CAN data (or command) received. DS9 3,3 V Green ON when the 3.3 V supply voltage is OK OFF when the 3.3 V supply voltage is defective DS10 Microcontoller heartbeat Red Chapter 3 Behavior Blinks when the HC12 microcontroller is alive, representing the heartbeat of the HC12 microcontroller. OFF when the HC12 microcontroller is dead. Page no. 288 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 4-2-1. Stepper Board (Compression Board PL303 and Tilt Board PL401) Fuses Fuse Specification PN Function F1 60 Vac, 0.3 A, CMS, Resettable 5314541-5 Resettable thermal protection 5V power supply for Paddle Holder Board (Compression Paddle recognizing) F2 60 Vac, 0.3 A, Resettable 2214421 Resettable thermal protection 5V power supply for Key Pads. F3 Resettable thermal protection 5V power supply for Compression coder and for Tilt coder. Page no. 289 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 4-3. • PDU Board PL101 Board-PDU PL101; see component index page 158 . J4 J2 J5 J7 DS2 J6 S3 S2 S1 DS1 F3 F5 F1 F4 DS5 DS6 DS26 DS7 F6 DS24 DS8 J8 S4 PRGM DS25 J9 J22 J1 DS14‐13‐11‐10‐12‐9 DS15, 18 J3 DS21‐20‐19‐17‐16 J11 Fuse Specification PN F1 250 Vac, 6.25 A, Delay 46-170021P60 F3 250 Vac, 0.5A, Delay 46-170021P31 F4 250 Vac, 2A, Delay 46-170021P30 F5 250 Vac, 125 mA, Delay 5344386-2 J10 Protects F6 Jumper Function Position PRGM Used to program the PDU board during manufacturing. Closed to program the PDU board. Open for normal PDU board operation. This jumper must always be open. J22 Used to turn on/off 48 V when the PDU board is in programming mode. Bottom two pins closed turn 48 V off. Top two pins closed turn 48 V on. Open enables normal PDU board operation, where the 48 V is controlled by the Senographe system. This jumper must always be open. LED Function Color DS1 DMR On Green ON when the Generator is ON OFF when the Generator is OFF DS2 48 V Green ON when 48 V DC supply voltage is OK OFF when 48 V DC supply voltage is defective DS3 Minus sign used for error codes Red DS4 Minus sign used for error codes Red Chapter 3 Behavior Sometimes ON when reporting certain error codes. Page no. 290 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing DS5 Figure of 8 LED used for error codes Red DS6 DS7 When the system is functioning properly these LEDs spell dEF. If the system has errors, these LEDs display different error codes. DS8 DS9 Presence SECTeur A status signal indicator from the AC/DC 48 V power supply Default state:OFF Not used. DS10 Power OK A status signal indicator from the AC/DC 48 V power supply Yellow ON when 48 V is not present at power supply output or when the power is inhibited (i.e. bottom two pins of jumper J22 are closed). OFF when 48 V is present at power supply output or when the power is not inhibited (i.e. the jumper J22 is open). DS11 Over Temperature Yellow ON when the PDU temperature is too high. OFF when the PDU temperature is not too high. DS12 Fan Fail Yellow ON when the fan on the PDU has failed. OFF when the fan on the PDU has failed. DS13 Power ON/OFF A control signal indicator from the PDU to AC/DC 48 V power supply Yellow ON when the power is inhibited (i.e. bottom two pins of jumper J22 are closed) or when PDU turns off the 48 V power. OFF when the power is not inhibited (i.e. the jumper J22 is open) or when PDU turns on the 48 V power. Note: Normal operation is that power is not inhibited (i.e. the jumper J22 is open) and the LED is OFF. DS14 48 V DC ON/OFF Safety indicator Red If DS13 is wrong or insertion is wrong, the behavior is the same as DS13, otherwise: ON when PDU turns off the 48 V power OFF when PDU turns on the 48 V power DS15 + Input Green ON when the + U supply voltage is OK OFF when the + U supply voltage is defective DS16 + 5 VD Green ON when the 5 V logic supply voltage is OK OFF when the 5 V logic supply voltage is defective DS17 + 13 V Green ON when the 13 V supply voltage is OK OFF when the 13 Vv supply voltage is defective DS18 – Input Green ON when the – U supply voltage is OK OFF when the – U supply voltage is defective DS19 + 5 VA Green ON when the +5 VA analog supply voltage is OK OFF when the +5 VA analog supply voltage is defective DS20 – 5 VA Green ON when the –5 VA analog supply voltage is OK OFF when the –5 VA analog supply voltage is defective DS21 + 12 V System Green ON when the 12 V system supply voltage is OK OFF when the 12 V system supply voltage is defective Page no. 291 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing DS22 Relay 1 Active Yellow ON when relay 1 is active OFF when relay 1 is idle DS23 Relay 2 Active Yellow ON when relay 2 is active OFF when relay 2 is idle DS24 Reset PDU Board Red ON while the PDU board is being reset. OFF when the PDU board is functioning normally. DS25 Watchdog Yellow ON when the watchdog is alive OFF when the watchdog is no longer refreshed or dead DS26 AC Power ON Green ON when the 220 V AC supply is okay OFF when the 220 V AC supply is defective or not connected Chapter 3 Page no. 292 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 4-4. • Interface Board PL104 Board-Interface PL104; see component index page 158 . DS12 DS11 DS9 DS6 DS5 DS13 DS10 DS8 DS7 DS4 J11 J3 J2 J1 DS3 DS2 DS1 J4 J7 J6 Jn1 Jn2 LED Function Color Behavior DS1 5V Green ON when 5v supply voltage is OK OFF when 5v supply voltage is defective DS2 3,3 V Green ON when 3.3v supply voltage is OK OFF when 3.3v supply voltage is defective DS3 15 V Green ON when 15v supply voltage is OK OFF when 15v supply voltage is defective DS4 Enable Reset Red ON while the Interface board is being reset. OFF when the Interface board is functioning normally. DS5 Reset Interface Board Red ON while the Interface board is being reset. OFF when the Interface board is functioning normally. DS6 FPGA not configured Red On when the FPGA is not configured. The board is faulty and needs replacing. OFF when the FPGA is configured, and the board is operating correctly. DS7 Not used Green Not used (debug only) DS8 Ethernet RX Green ON when the Interface board receives Ethernet data. OFF when the Interface board receives no Ethernet data. DS9 Not used Green Not used (debug only) DS10 X-Ray On Yellow ON when X-Rays are being generated OFF when X-Rays are not being generated DS11 Active link connection Green ON when active Ethernet connection exists. OFF when no active Ethernet connection exists. DS12 Exposure Command Yellow ON when an exposure command is received OFF when no exposure command is received DS13 Exposure Enable Yellow ON when an exposure is currently enabled OFF when an exposure is currently not enabled Page no. 293 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 4-5. • Bucky Board PL302 Board-Bucky PL302; see component index page 157 . J1 J2 DS2 DS3 J3 DS6 DS8 DS7 DS9 DS10 J4 J5 DS11 LED Function Color Behavior DS1 48 V Green ON when the 48 V DC supply voltage is OK OFF when the 48 V DC supply voltage is defective DS2 Data CAN reception Yellow ON when CAN data (or command) received. OFF when no CAN data (or command) received. DS3 RT2 Synchro Grid Yellow n/a DS4 Not present n/a n/a DS5 Not present n/a n/a DS6 Microcontroller Debug Green n/a DS7 Microcontroller Heartbeat Green Blinks once every second when the Bucky board is okay Blinks more than once a second or is constantly ON or constantly OFF when the bucky board is faulty DS8 Microcontroller Debug Green n/a DS9 5V Green ON when the 5 V supply voltage is OK OFF when the 5 V supply voltage is defective DS10 3.3 V logic Green ON when the 3.3 V supply voltage is OK OFF when the 3.3 V supply voltage is defective DS11 Optical Fork Behavior Green ON when the optical fork on the Bucky is masked (i.e. the Bucky grid is initialized) OFF when the optical fork on the Bucky is not masked (i.e. the Bucky grid is no initialized) Chapter 3 Page no. 294 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 4-6. • Collimator Control Board PL403 Board-Collimator Control PL403; see component index page 157 . To DC‐DC Board J9 DS1 DS2 TP17 DS4 SW1 DS3 DS6 J8 DS5 DS7 DS9 DS8 Component J10 DS10 Function LED Color Behavior Jumper present: Firmware upgrade Jumper absent: Normal setting N/A N/A Reset N/A N/A DS1 24 V Green ON when the 24 V supply voltage is OK OFF when the 24 V supply voltage is defective DS2 Lamp ON Green ON when the Collimator Lamp is on. OFF when the Collimator Lamp is off. DS3 2.5 V Green ON when the 2.5 V supply voltage is OK OFF when the 2.5 V supply voltage is defective DS4 5V Green ON when the 5 V supply voltage is OK OFF when the 5 V supply voltage is defective DS5 Init. done Green ON or BLINKING when the Collimator Control board is initializing. OFF when the Collimator Control board has initialized and functioning normally. Jumper: TP17 Switch: SW1 LED: Page no. 295 Indicators and Switches.fm Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing DS6 3.3 V Green DS7 DS8 DS9 Red Error indicators Not used - for future application DS10 4-7. • ON when the 3.3 V supply voltage is OK OFF when the 3.3 V supply voltage is defective Error indicators Not used - for future application Red Red Red DC-DC Board PL402 (Collimator Supply) Board-Collimator DC-DC PL402; see component index page 157 . To Control Board J4 TP4 TP2 To Light J5 TP1 TP3 TP7 TP5 TP6 J3 Chapter 3 Jumper/Test Point Function TP1 Jumper present: Lamp ON (test) Jumper absent: Normal setting TP2 Trim (not used) TP3 Gnd (24 V) TP4 24 V TP5 Trim (not used) TP6 Gnd (12 V) TP7 12 V 48 V Page no. 296 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Central Listing 5. GANTRY MPCB SWITCHES AND FUSES Stop Motion button - Left. (one either side of column. PDU Board PL101 (for fuses, etc., see PDU Board PL101 on page 290). F1/F2 Fuse, 600 Vac, 20 A, Fast Circuit Breaker 10 A 5-1. MPCB Fuses Fuse Specification PN F1 600 Vac, 20 A, Fast 2387747 Function F2 Page no. 297 Indicators and Switches.fm Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Central Listing This page is blank. Chapter 3 Page no. 298 Indicators and Switches.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out Cable Lay-out and Pin-out Chapter 3 This section lists Senographe system internal and external connecting cables. 1. GANTRY CABLING 1-1. W001 - Earth Cable 1 MPCB box to Ground bar G301. 1-2. W002 - Earth Cable for EMC Filter E101 MPCB box to EMC filter E101. 1-3. W004 - Earth Cable for AC/DC Module Board PS101 MPCB box to AC/DC Module board PS101. 1-4. W005 - Earth Cable for AC/DC Converter Module MPCB box to AC/DC Converter Module. 1-5. W006 - Earth Cable for Bulkhead Cover MPCB box to bulkhead cover. 1-6. W101 - SYS-Bus 1 PDU Board to Interface Board Connector: B20B-PHDSS 20 points - two in parallel PDU Board PL101 J8 to Interface Board PL104 J2: Pin N° Signal Name Signal description J2-1 H-Expose Enable RT-CAN Diff 5/2.5V J2-2 L-Expose Enable RT-CAN Diff 2.5/0V J2-3 Spare J2-4 0 Power Supply Ground J2-5 H-Expose Command RT-CAN Diff 5/2.5V J2-6 L-Expose Command RT-CAN Diff 2.5/0V J2-7 Ground Ground J2-8 P Reset Command RT 0/+5V J2-9 H-Xray On RT-CAN Diff 5/2.5V J2-10 L-Xray On RT-CAN Diff 2.5/0V J2-11 P Power On Command/reserved Page no. 299 Cables.FM Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-7. J2-12 L Power On Command/reserved J2-13 H-Motion Enable RT-CAN Diff 5/2.5V J2-14 L-Motion Enable RT-CAN Diff 2.5/0V J2-15 Command CAN Electric CAN Ground J2-16 P Power supply 12 V J2-17 H-CAN Network CAN Diff 5/2.5V J2-18 L-CAN Network CAN Diff 2.5/0V J2-19 H-Spare RT-CAN Diff 5/2.5V J2-20 L-Spare RT-CAN Diff 2.5/0V W104 - PDU Power Cable PDU Board PL101 J1 to EMC filter E101 P’, N’. E101 J1 P’ 1 N’ 1-8. Shielding 4 W105 - 48 V DC Cable AC/DC Converter Module J2 to EMC Filter E102 N. 1-9. W106 - AC/DC Power AC/DC Module Board PS101 J137 to EMC filter E101 P’, N’. E101 W 106 2345983 J137 1 Pin 1 : Phase Pin 3 : N 3 1-10. W107 - AC/DC Databus AC/DC Module Board PS101 J138 to PDU Board PL101 J3. Chapter 3 Page no. 300 Cables.FM GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-11. W108 - 48 V DC Cable AC/DC Converter Module J1 to EMC Filter E102 P. 1-12. W110 - 48 V DC PDU Board PL101 J5 to Terminal block ST102. 1-13. W109/W111/W113 - Shunt Cables Shunt resistor and cable assembly: Shunt R101 W109 1 W109 - 48 V DC connects shunt resistor R101 to the EMC filter E102. W111 - 48 V DC connects shunt resistor R101 to the PDU Board PL101. W113 - 48 V DC connects shunt resistor R101 to the terminal block ST102-F1/2. R 4.7kOhm 0.5W 5 % W113 2 W111 AC/DC PS101 J1 J4 PDU Board PL101 1-14. W111 - 48 V DC Cable See W109/W111/W113 - Shunt Cables on page 301. 1-15. W112 - 48 V DC Cable 4 EMC filter E102 N’ to Terminal Block ST102-X1. 1-16. W113 - 48 V DC Cable See W109/W111/W113 - Shunt Cables on page 301. Page no. 301 Cables.FM Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-17. W114/W116/W209 - PDU Board J7 Connections F u se 2 o n T e rm in a l B lo c k ST102 PDU B o a rd PL101 W 11 4 In te rfa c e B o a rd PL104 J1 J7 W 11 6 W 209 L ift B o a rd PL201 J2 7 8 9 10 11 12 1 2 3 4 5 6 W114 - Column Fuse Check PDU Board PL101 J7 Pin 1 to Terminal 2 ST102-F1/1. W116 - PL104 power PDU Board PL101 J7 to Interface Board PL104 J1. Pin no. Level Pin no. PL 104 J1-1 +48 V PL 101 J7-5 PL 104 J1-2 GND PL 101 J7-11 W209 - 48 V LP1 PDU board PL101 J7 to Lift Board PL201 J2: Pin no. Functions Pin no. PL 201 J2-1 + 48 Volts (max. 100 mA) PL 101 J7-3 PL 201 J2-2 GND PL 101 J7-9 1-18. W116 - PL104 Power See W114/W116/W209 - PDU Board J7 Connections on page 302. 1-19. W117 - Terminal Block Interconnection Terminal block ST102 from F1/2 to F2/2. 1-20. W119 - Serial Link TX Generator to Interface Board Generator Interface J7 to Interface Board PL104 J9. Chapter 3 Page no. 302 Cables.FM GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-21. W120 - Serial Link RX Generator from Interface Board Generator Interface J6 to Interface Board PL104 J10. 1-22. W121 - Grid Sync Generator to Interface Board Interface Board PL104 J8 to Generator (Grid sync.) J19. 1-23. W123 - Terminal Block Interconnection Terminal block ST102 from B/1 to P’. 1-24. W124 - AC Supply to Gantry Generator J7 to Terminal 1 ST101-3. 1-25. W125 - 12 V DC Supply to PDU Board and Generator Shutdown Signal PDU Board PL101 J2 to Generator. Pin no. on PL101 Functions Location on Generator PL 101 J2-1 HV Supply shutdown signal Orange coupling block (which leads to TB1-1) PL 101 J2-2 HV Supply shutdown signal Orange coupling block (which leads to TB1-2) PL 101 J2-3 12 V DC PDU Board supply from Generator TP10 connector on Supply Command Board 200PL2 PL 101 J2-4 GND Top left ground bolt on Supply Command Board 200PL2 If the error 152/001 12VDC Generator voltage off occurs, there may be an issue with the W125 Cable, PDU Board, or the Generator Supply Command board. For more information, refer to JC DIAG A1501 12V DC Generator Voltage Off on page 971. Page no. 303 Cables.FM Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-26. W127 - EMC Filter EMC filter E101 to Terminal block ST101. 1-27. W129 - Terminal Block Interconnection Terminal Block Interconnection from X4 P’ to B2/1. 1-28. W201 - Lift Optical Fork Connect (Upper) Lift Board PL201 J4 to opto detector S201: Designation Type Level Pin N° VCC_Led_1 VCC 5V J4-1 GND Ground 0V J4-2 Fork_Opt_Out_ 1 Open coll. 0 / +5 V GND Ground 0V S201 300 J4 W 201 2345937 1 J4-3 A K J4-4 C E 3 4 2 1-29. W202 - Lift Optical Fork Connect (Lower) Lift Board PL201 J5 to opto detector S202. 1-30. W203 - Lift Potentiometer Lift Board PL201 J11 to potentiometer R201: R201 Designation Type Level Pin N° VCC VCC 5V J11-1 Pot. Analog. 0/5V J11-2 GND Ground 0V J11-3 J11 Vcc Vout 1 2 3 GND 1-31. W204 - LCD Connect Lift Board PL201 J15 to LCD DS201. Chapter 3 Page no. 304 Cables.FM GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-32. W205/206 Motor and Encoder Connect; Lift and Rotation Motors Motor and cable assembly used in two places, with Lift Board PL201 and Rotation Board PL202. W205: Board PL201/2 J9 to encoder U201. W206: Board PL201/2 J10 to motor M201. Color PIN ITEM Red J9-1 +DC 5 V Black and Shield J9-2 GND Blue J9-3 A-Channel Brown J9-4 /A-Channel Green J9-5 B-Channel Purple J9-6 /B-Channel White J9-7 C-Channel Yellow J9-8 /C-Channel 1-33. W207/222 - Footswitch Cables Lift Board PL201 J6 to Foot Switch PL202 J1. 1-34. W208 - POS-Bus1 Interface Board PL104 J3 to Lift Board PL201 J3. PIN (PL104) Designation Type Level PIN (PL201) PL104/J3-1 H-CAN Network CAN Diff 5 / 2.5V PL201/J3-1 PL104/J3-2 L-CAN Network CAN Diff 2.5 / 0V PL201/J3-2 PL104/J3-3 GND Ground 0V PL201/J3-3 PL104/J3-4 H-RT line 1 RT-CAN Diff 5 / 2.5 V PL201/J3-4 PL104/J3-5 L-RT line 1 RT-CAN Diff 2.5 / 0V PL201/J3-5 PL104/J3-6 Stop motion RT 0/+5 V PL201/J3-6 PL104/J3-7 H-RT line 2 RT-CAN Diff 5 / 2.5 V PL201/J3-7 PL104/J3-8 L-RT line 2 RT-CAN Diff 2.5 / 0V PL201/J3-8 PL104/J3-9 Reset line RT 0/+5 V PL201/J3-9 PL104/J3-10 GND Ground 0V PL201/J3-10 PL104/J3-11 H-RT line 3 RT-CAN Diff 5 / 2.5 V PL201/J3-11 PL104/J3-12 L-RT line 3 RT-CAN Diff 2.5 / 0V PL201/J3-12 Page no. 305 Cables.FM Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-35. W209 - 48 V LP1 See W114/W116/W209 - PDU Board J7 Connections on page 302. 1-36. W210 - 48 V DC HP Lift Board PL201 J1 to MPCB Terminal 1 ST102. N° Pin Functions J1-1 + 48 Volts J1-2 0 Volt 1-37. W211 - 48 V DC HP between Boards Lift Board PL201 J12 to Rotation Board PL202 J1. N° Pin Functions J12-1 0 Volt J12-2 + 48 Volts (max. 15 A avg. 30 A (3 s)) 1-38. W212 - 48 V DC LP1 Lift Board PL201 J13 to Rotation Board PL202 J2. Chapter 3 N° Pin Functions J13-1 0 Volt J13-2 + 48 Volts (max. 100 mA) Page no. 306 Cables.FM GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-39. W213 - POS-Bus 1 between Boards Rotation Board PL202 J3 to Lift Board PL201 J14. PIN (PL202) Designation Type Level PIN (PL201) PL202/J3-1 H-CAN Network CAN Diff 5 / 2.5V PL201/J14-1 PL202/J3-2 L-CAN Network CAN Diff 2.5 / 0V PL201/J14-2 PL202/J3-3 GND Ground 0V PL201/J14-3 PL202/J3-4 H-RT line 1 RT-CAN Diff 5 / 2.5 V PL201/J14-4 PL202/J3-5 L-RT line 1 RT-CAN Diff 2.5 / 0V PL201/J14-5 PL202/J3-6 Stop motion RT 0/+5 V PL201/J14-6 PL202/J3-7 H-RT line 2 RT-CAN Diff 5 / 2.5 V PL201/J14-7 PL202/J3-8 L-RT line 2 RT-CAN Diff 2.5 / 0V PL201/J14-8 PL202/J3-9 Reset line RT 0/+5 V PL201/J14-9 PL202/J3-10 GND Ground 0V PL201/J14-10 PL202/J3-11 H-RT line 3 RT-CAN Diff 5 / 2.5 V PL201/J14-11 PL202/J3-12 L-RT line 3 RT-CAN Diff 2.5 / 0V PL201/J14-12 1-40. W215 - Rotation Optical Fork Connect Rotation Board PL202 J5 to optical detector S203. Designation Type Level Pin N° VCC_Led_1 VCC 5V J5-1 GND Ground 0V J5-2 Fork_Opt_Out_1 Open coll. 0 / +5 V J5-3 GND Ground 0V J5-4 1-41. W216 - Stop Motion Connect (Right) Emergency Stop R-Button S205 to Interface Board PL104 J6. 1-42. W217 - Stop Motion Connect (Left) Emergency Stop L-Button S206 to Interface Board PL104 J7. 1-43. W218/221 - Clutch Cables W218: Clutch B201 to Rotation Board PL202 J8. W221: Clutch B201 to Rotation Board PL202 J7. Page no. 307 Cables.FM Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-44. W219 - Electromagnetic Brake Connect Electromagnetic Brake B202 to rotation Board PL202 J6. 1-45. W220 - Rotation Potentiometer Potentiometer R202 to Rotation Board PL202 J11. Designation Type Level Pin N° VCC VCC 5V J11-1 Pot. analog 0 / +5 V J11-2 GND Ground 0V J11-3 1-46. W221 - Clutch Cable See W218. 1-47. W222 - Footswitch Cable See W207. 1-48. W301 - Compression Stepper Motor Stepper Motor M301 to Compression Board PL303 J3. Chapter 3 Color ITEM Red +DC 5 V Orange GND Yellow NC Brown NC Blue A-Channel Green /A-Channel Gray B-Channel Violet /B-Channel Tbd C-Channel White /C-Channel Designation Type Level Pin N° OUT_1A Hbridge 0 / 48 Volts J3-1 OUT_1B Hbridge 0 / 48 Volts J3-2 OUT_2A Hbridge 0 / 48 Volts J3-3 OUT_2B Hbridge 0 / 48 Volts J3-4 Page no. 308 Cables.FM GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-49. W302 - Compression Stepper Encoder Encoder U301 to Compression Board PL303 J4: Designation Type Level Pin N° +DC 5 V VCC 5V J4-1 GND 0V Ground J4-2 A-Channel TTL 0/+5 V J4-5 /A-Channel TTL 0/+5 V J4-6 B-Channel TTL 0/+5 V J4-7 /B-Channel TTL 0/+5 V J4-8 C-Channel TTL 0/+5 V J4-9 /C-Channel TTL 0/+5 V J4-10 1-50. W303 - Compression Potentiometer Connect Potentiometer R301 to Compression Board PL303 J6: Designation Type Level Pin N° VCC VCC 5V J6-1 Pot. Analog. 0/5 V J6-2 GND Ground 0V J6-3 1-51. W304A/W304B - Paddle Detector Card Connect Paddle detector PL304 J2 to Compression Board PL303 J10: Designation Level Pin N°. VCC 5V J10-1 GND 0V J10-2 Force_Sensor Analog J10-3 Paddles bit 0 (LSB) Open collector J10-4 Paddles bit 1 Open collector J10-5 Paddles bit 2 Open collector J10-6 Paddles bit 3 Open collector J10-7 Paddles bit 4 (MSB) Open collector J10-8 Pos_Paddles bit 0 (LSB) Open collector J10-9 Pos_Paddles bit 1 (MsSB) Open collector J10-10 Brake_1 + 48 V J10-11 Brake_2 Open collector J10-12 Page no. 309 Cables.FM Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-52. W305 - Arm Control Keypad Connect FromArm Control Keypad PL305 J1 (on right or left of Arm) to Compression Board PL303 J7 or J8: Designation Level Pin N° Lift up slow speed_A Contact to gnd J7/J8-1 Lift up slow speed_B Contact to gnd J7/J8-2 Lift up High speed_A Contact to gnd J7/J8-3 Lift up High speed_B Contact to gnd J7/J8-4 Lift down slow speed_A Contact to gnd J7/J8-5 Lift down slow speed_B Contact to gnd J7/J8-7 Lift down High speed_A Contact to gnd J7/J8-6 Lift down High speed_B Contact to gnd J7/J8-8 Rotation left slow speed_A Contact to gnd J7/J8-9 Rotation left slow speed_B Contact to gnd J7/J8-10 Rotation left high speed_A Contact to gnd J7/J8-11 Rotation left high speed_B Contact to gnd J7/J8-12 Rotation right slow speed_A Contact to gnd J7/J8-13 Rotation right slow speed_B Contact to gnd J7/J8-14 Rotation right high speed_A Contact to gnd J7/J8-15 Rotation right high speed_B Contact to gnd J7/J8-16 MLO_R_A Contact to gnd J7/J8-17 MLO_R_B Contact to gnd J7/J8-18 MLO_L_A Contact to gnd J7/J8-19 MLO_L_B Contact to gnd J7/J8-20 CC_A Contact to gnd J7/J8-21 CC_B Contact to gnd J7/J8-22 Spare_1_A Contact to gnd J7/J8-23 Spare_2_B Contact to gnd J7/J8-24 GND GND J7/J8-25 +VCC 5 V VCC J7/J8-26 1-53. W306 - Earth Cable Arm Connect Arm to ground bar G301. 1-54. W307 - 48v dc-LP2 for Compression Arm Distribution Board PL301 J5 to Compression Board PL303 J1: Chapter 3 Pin N° Function Pin N° PL301/J5-1 48 Volts PL303/J1-1 PL301/J5-2 GND PL303/J1-2 Page no. 310 Cables.FM GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-55. W308 - POS-Bus 2 Compression Connect Compression Board PL303 J2 to Arm Distribution Board PL301 J6: Pin N° Designation Level Pin N° J2-1 CAN Diff 5 / 2.5 V J6-1 J2-2 CAN Diff 2.5 / 0 V J6-2 J2-3 Ground 0V J6-3 J2-4 RT-CAN Diff 5 / 2.5 V J6-4 J2-5 RT-CAN Diff 2.5 / 0 V J6-5 J2-6 RT 0V J6-6 J2-7 RT-CAN Diff 5 / 2.5 V J6-7 J2-8 RT-CAN Diff 2.5 / 0 V J6-8 J2-9 RT 0 / +5 V J6-9 J2-10 Ground 0V J6-10 J2-11 RT-CAN Diff 5 / 2.5 V J6-11 J2-12 RT-CAN Diff 2.5 / 0 V J6-12 1-56. W309 - Screw Brake Connect Screw brake B303 to Compression Board PL303 J5: Color Designation Type Level Pin N° Green/Red VCC_48 VCC 48 Volts J5-1 Green/Blue Cmd_Brake Open Coll. 0 / 48 Volts J5-2 1-57. W310 - 48V to Bucky Board P/N: 2372183 Distribution Board PL301 J4 to connector J4a, then from J2a to Bucky Board PL302 J2: N° Pin Functions N° Pin J4/J4a-1 + 48 Volts J2/J2a-1 J4/J4a-2 GND J2/J2a-2 1-58. W311 - POS-Bus 2 for Bucky Distribution Board PL301 J3 to connector J3a, then from J1a to Bucky Board PL302 J1: PIN (PL301) Designation Type Level PIN (PL302) PL301/J3-1 H-CAN Network CAN Diff 5 / 2.5V PL302/J1-1 PL301/J3-2 L-CAN Network CAN Diff 2.5 / 0V PL302/J1-2 PL301/J3-3 GND Ground 0V PL302/J1-3 PL301/J3-4 Not Used PL301/J3-5 Not Used PL301/J3-6 Not Used Page no. 311 Cables.FM Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out PL301/J3-7 H-RT line 2 RT-CAN Diff 5 / 2.5 V PL302/J1-7 PL301/J3-8 L-RT line 2 RT-CAN Diff 2.5 / 0V PL302/J1-8 PL301/J3-9 Not used PL301/J3-10 GND Ground 0V PL302/J1-10 PL301/J3-11 Not used PL301/J3-12 Not used 1-59. W312 - Stepper Motor to Bucky Board Stepper Motor M302 to Bucky Board PL302 J3: Designation Type Level PIN OUT_1A Hbridge 0 / 48 Volts J3-1 OUT_1B Hbridge 0 / 48 Volts J3-2 OUT_2A Hbridge 0 / 48 Volts J3-3 OUT_2B Hbridge 0 / 48 Volts J3-4 1-60. W313 - Compression Board to Bucky Board Compression Board PL303 J9 to connector J4a, then from J2a to Bucky Board PL302 J2: Chapter 3 PIN (PL303) Designation Colour PIN (connector J4a) PL301/J9-1 GND Red PL302/J4a-6 PL301/J9-2 Rec 0 Black PL302/J4a-3 PL301/J9-3 Signal 1 Yellow PL302/J4a-4 PL301/J9-4 Signal 2 Green PL302/J4a-5 Page no. 312 Cables.FM GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-61. W314 - SYS-POS-Bus Cable Interface Board PL104 J5 to Arm Distribution Board PL301 J1: PIN (PL104) Designation Type Level J5-1 H-CAN Bus Column CAN Diff 5 / 2.5V J5-2 GND Ground 0V J5-3 L-CAN RT1 Column RT-CAN Diff 2.5 / 0V J5-4 L-CAN RT2 Column RT-CAN Diff 5 / 2.5V J5-5 Reset Line Column RT 0/+5 V J5-6 H-CAN RT3 Column RT-CAN Diff 5 / 2.5V J5-7 H-Expose Enable RT 0/+5 V J5-8 Spare N/A N/A J5-9 H-Expose Command RT 0/+5 V J5-10 GND Ground 0V J5-11 H-Xray On RT 0/+5 V J5-12 P-Power On RT 0/+5 V J5-13 H-Motion Enable RT 0/+5 V J5-14 Command CAN Electric CAN 0 V (CAN Gnd) J5-15 H-CAN Network CAN Diff 5 / 2.5V J5-16 H-Spare N/A N/A J5-17 NC N/A N/A J5-18 NC N/A N/A J5-19 NC N/A N/A J5-20 L-CAN Bus Column CAN Diff 2.5 / 0 V J5-21 Stop Motion Line Column RT 0/+5 V J5-22 H-CAN RT1 Column RT-CAN Diff 5 / 2.5 V J5-23 L-CAN RT2 Column RT-CAN Diff 2.5 / 0 V J5-24 GND Ground 0V J5-25 L-CAN RT3 Column RT-CAN Diff 2.5 / 0 V J5-26 L-Expose Enable RT-CAN 0/+2.5 V J5-27 GND Ground 0V J5-28 L-Expose Command RT-CAN 0/+2.5 V J5-29 P-Reset RT 0V J5-30 L-Xray On Ground 0/+2.5 V J5-31 L-Power On RT 0/+2.5 V J5-32 L-Motion Enable RT 0/+2.5 V J5-33 P-Power Supply 2.4W PWR 12 V (200 mA) J5-34 L-CAN Network CAN Diff 2.5 / 0 V J5-35 L-Spare N/A N/A J5-36 NC N/A N/A J5-37 NC N/A N/A Page no. 313 Cables.FM Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-62. W315 - 48v dc-LP2 PDU Board PL101 J6 to Arm Distribution Board PL301 J2: N° Pin Functions N° Pin J6-1 + 48 Volts J2-1 J6-2 GND J2-2 1-63. W316 - Image Receptor Earth Connect Ground bar G301 to Image receptor. 1-64. W317 - Compression Trolley Earth Connect Ground bar G301 to Compression Trolley. 1-65. W318 - Compression Block Connect Manual Brake B301 to Paddle Detect. Board PL304: Green/Blue (-) Green/Red (+) 1-66. W319 - Force Sensor Force Sensor B302 to Paddle Detect. Board PL304. 1-67. W320 - Earth Cable for Paddle Holder Paddle Holder PL304 to Ground. 1-68. W401 - 48v dc-LP2 Arm Distribution Board PL301 J8 to Collimator DC/DC PL402 J5: PIN Function PIN J1-1 0 Volts J8-2 J1-2 + 48 Volts J8-1 1-69. W402 - Thermoswitch Connect Chapter 3 Designation Level Pin N° Power supply 15 V J4-2 secu_sheath 15 V or 0 V(failure) J4-1 Page no. 314 Cables.FM GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-70. W403 - Stator, Thermoswitch and +HT Connect Designation Level Pin N° Power supply 15 V J1a-2 secu_sheath 15 V or 0 V(failure) J1a-1 1-71. W404 - Tube Tilt Stepper Motor Connect Tilt Board PL401 J3 to the Stepper motor M401: Designation Type Level Pin N° OUT_1A Hbridge 0 / 48 Volts J3-1 OUT_1B Hbridge 0 / 48 Volts J3-2 OUT_2A Hbridge 0 / 48 Volts J3-3 OUT_2B Hbridge 0 / 48 Volts J3-4 1-72. W405 - Tube Tilt Zero Sensor Connect Tilt Board PL401 J12 to Optical fork S401: Designation Type Level Pin N° VCC_Led_1 VCC 5V J12-1 GND Ground 0V J12-2 Fork_Opt_Out_1 Open coll. 0 / +5 V J12-3 GND Ground 0V J12-4 1-73. W406 - Fan Connect Tilt Board PL401 J11 to Fan V401: Designation Level Pin N° VCC 48 V J11-1 GND 0V J11-2 Speed signal Open collector J11-3 Page no. 315 Cables.FM Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-74. W407 - Arm Control Keypad Connect From Arm Control Keypad PL404 J1 (on right or left of Tube Head) to Tilt Board PL401 J7 or J8: Designation Level Pin N° Lift up slow speed_A Contact to gnd J7/J8-1 Lift up slow speed_B Contact to gnd J7/J8-2 Lift up High speed_A Contact to gnd J7/J8-3 Lift up High speed_B Contact to gnd J7/J8-4 Lift down slow speed_A Contact to gnd J7/J8-5 Lift down slow speed_B Contact to gnd J7/J8-7 Lift down High speed_A Contact to gnd J7/J8-6 Lift down High speed_B Contact to gnd J7/J8-8 Rotation left slow speed_A Contact to gnd J7/J8-9 Rotation left slow speed_B Contact to gnd J7/J8-10 Rotation left high speed_A Contact to gnd J7/J8-11 Rotation left high speed_B Contact to gnd J7/J8-12 Rotation right slow speed_A Contact to gnd J7/J8-13 Rotation right slow speed_B Contact to gnd J7/J8-14 Rotation right high speed_A Contact to gnd J7/J8-15 Rotation right high speed_B Contact to gnd J7/J8-16 MLO_R_A Contact to gnd J7/J8-17 MLO_R_B Contact to gnd J7/J8-18 MLO_L_A Contact to gnd J7/J8-19 MLO_L_B Contact to gnd J7/J8-20 CC_A Contact to gnd J7/J8-21 CC_B Contact to gnd J7/J8-22 Spare_1_A Contact to gnd J7/J8-23 Spare_2_B Contact to gnd J7/J8-24 GND GND J7/J8-25 +VCC 5 V VCC J7/J8-26 1-75. W408 - Earth Cable X-ray Tube Ground bar G301 to the X-ray Tube. Chapter 3 Page no. 316 Cables.FM GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-76. W409 - SYS-Bus-2 Collimator Connect Arm Distribution Board PL301 J7 to Collimator PL403 J1: Signal name Signal nature Pin N° H-Expose Enable RT-CAN Diff 5/2.5V J7-1 L-Expose Enable RT-CAN Diff 2.5/0V J7-2 Spare J7-3 0 Power supply Ground J7-4 H-Expose Command RT-CAN Diff 5/2.5V J7-5 L-Expose Command RT-CAN Diff 2.5/0V J7-6 Ground Ground J7-7 P Reset Command RT 0/+5V J7-8 H-Xray On RT-CAN Diff 5/2.5V J7-9 L-Xray On RT-CAN Diff 2.5/0V J7-10 P Power On Command/reserved J7-11 L Power On Command/reserved J7-12 H-Motion Enable RT-CAN Diff 5/2.5V J7-13 L-Motion Enable RT-CAN Diff 2.5/0V J7-14 Common CAN Electric CAN Ground J7-15 P Power supply 12 V J7-16 H-CAN Network CAN Diff 5/2.5V J7-17 L-CAN Network CAN Diff 2.5/0V J7-18 H-Spare RT-CAN Diff 5/2.5V J7-19 L-Spare RT-CAN Diff 2.5/0V J7-20 1-77. W410 - 48 V DC-LP2 Tilting Connect Arm Distribution Board PL301 J10 to Tilt Board PL401 J1: PIN N° Function Pin N° J10-1 + 48 Volts J1-1 J10-2 GND J1-2 Page no. 317 Cables.FM Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-78. W411 - POS-Bus-2 Tilting Connect Tilt Board PL401 J2 to Arm Distribution Board PL301 J9: PIN (PL401) Designation Type Level PIN (PL301) PL401/J9-1 H-CAN Network CAN Diff 5 / 2.5V PL301/J9-1 PL401/J9-2 L-CAN Network CAN Diff 2.5 / 0V PL301/J9-2 PL401/J9-3 GND Ground 0V PL301/J9-3 PL401/J9-4 H-RT line 1 RT-CAN Diff 5 / 2.5 V PL301/J9-4 PL401/J9-5 L-RT line 1 RT-CAN Diff 2.5 / 0V PL301/J9-5 PL401/J9-6 Stop motion RT 0/+5 V PL301/J9-6 PL401/J9-7 H-RT line 2 RT-CAN Diff 5 / 2.5 V PL301/J9-7 PL401/J9-8 L-RT line 2 RT-CAN Diff 2.5 / 0V PL301/J9-8 PL401/J9-9 Reset line RT 0/+5 V PL301/J9-9 PL401/J9-10 GND Ground 0V PL301/J9-10 PL401/J9-11 H-RT line 3 RT-CAN Diff 5 / 2.5 V PL301/J9-11 PL401/J9-12 L-RT line 3 RT-CAN Diff 2.5 / 0V PL301/J9-12 1-79. W412 - HV Cable Generator HV tank to X-ray tube J2. 1-80. W500 - Power/Lamp Control Cable DC-DC Board PL402 J4 to Control Board PL403 J9: Chapter 3 Designation Level Pin N° GND 0V J4-1 Power_good_N 0V J4-2 Power_good_P 0/12 V J4-3 Lamp_On Open collector J4-4 GND 0V J4-5 24 V 24 V J4-6 Page no. 318 Cables.FM GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-81. W501 - Motor Drive Cable Control Board PL403 J8 to Interconnection Board (2376693) CONN50. J8 and CONN50 are 50-pin connectors wired in five similar groups of 10 pins. Four groups are used for the four blades and one group for the filter wheel. Pins J8-x1 to J8-x10 in the table below correspond to the following pins: - Front blade; pins J8-1 to J8-10. - Left blade; pins J8-11 to J8-20. - Rear blade; pins J8-21 to J8-30. - Right blade; pins J8-31 to J8-40. - Filter wheel; pins J8-41 to J8-50. Designation Type Level Pin N° 1S2 N.C N.C J8-x1 1S4 Open coll.(optical sensor) 0/5V J8-x2 VCC VCC 5V J8-x3 GND Ground 0V J8-x4 1M1 H-bridge 0/24 V J8-x5 1M2 H-bridge 0/24 V J8-x6 GND Ground 0V J8-x7 VCC VCC 5V J8-x8 1M5 Quadrature encoder 0/5 V J8-x9 1M6 Quadrature encoder 0/5 V J8-x10 1-82. W502 – Lamp Cable 2 From Lamp Cable 3 (2377082-3) to Light Assembly: Designation Level Pin No. 12 V 12 V Pin1 GND 0V Pin2 1-83. W503 – Lamp Cable 3 From DC-DC board PL402 J5 to Lamp Cable 2 (2377082-2): Pin No. Level Pin No. J5-4 12 V Pin1 (Lamp Cable 2) J5-3 GND Pin2 (Lamp Cable 2) Page no. 319 Cables.FM Chapter 3 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-84. W504 – Rectangular Blade Optical Sensor Connect Four cables used to connect the rectangular blade optical sensor connectors (S1 through S4) to the Interconnection board connectors S1 through S4. Connectors Sx in the table below correspond to the following: - Front blade - S1; Left blade - S2; Rear blade - S3; Right blade - S4: Designation Level Pin No. VCC 5V Sx-1 LED-K 0/1.3 V Sx-2 GND 0V Sx-3 Zero 0/5 V Sx-4 1-85. W505 – Filter Wheel Optical Sensor Connect Filter Wheel optical sensor (S5) to Interconnection board S5: Designation Level Pin No. VCC 5V S5-1 LED-K 0/1.3 V S5-2 GND 0V S5-3 Zero 0/5 V S5-4 1-86. W506 – Rectangular Blade DC Motor Connect Four cables, used to connect the rectangular blade DC motor connectors (M1 through M4) to the Interconnection board connectors M1 through M4 (board PI 2376693). Connectors Mx in the table below correspond to the following: - Front blade - M1; Left blade - M2; Rear blade - M3; Right blade - M4: Chapter 3 Designation Level Pin No. Motor - 0/24 V Mx-1 Motor + 0/24 V Mx-2 GND 0V Mx-3 VCC 5V Mx-4 Channel B 0/5 V Mx-5 Channel A 0/5 V Mx-6 Page no. 320 Cables.FM GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 1-87. W507 – Filter Wheel DC Motor Connect Filter Wheel DC motor (M5) to Interconnection board (PI 2376693) M5: Designation Level Pin No. Motor - 0/24 V M5-1 Motor + 0/24 V M5-2 GND 0V M5-3 VCC 5V M5-4 Channel B 0/5 V M5-5 Channel A 0/5 V M5-6 1-88. W508 – Rectangular Blade Unit DC Motor Connect (Maxon) Four cables, used to connect the rectangular blade DC motor connectors (M1 through M4) to the Interconnection board connectors M1 through M4 (board PI 2408939). Connectors Mx in the table below correspond to the following: Front blade - M1; Left blade - M2; Rear blade - M3; Right blade - M4 Designation Level Pin No. Motor - 0/24 V Mx-1 Motor + 0/24 V Mx-2 GND 0V Mx-3 VCC 5V Mx-4 Channel B 0/5 V M5x5 Channel A 0/5 V Mx-6 1-89. W509 – Filter Wheel DC Motor Connect (Maxon) Filter Wheel DC motor (M5) to Interconnection board (PI 2408939) M5: Designation Level Pin No. Motor - 0/24 V M5-1 Motor + 0/24 V M5-2 GND 0V M5-3 VCC 5V M5-4 Channel B 0/5 V M5-5 Channel A 0/5 V M5-6 Page no. 321 Cables.FM Chapter 3 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Cable Lay-out and Pin-out 2. AWS CABLING 2-1. Cable 2226625 AWS Line 1: SB150 (bottom Line 1) 9 pin 2-2. Cable 2226621 IDC - Detector Power Supply. IDC SIB or Gitane 26 pin 2-3. Cable 2226612 IDC Conditioner Control IDC to Gantry Bulkhead Area then Bulkhead Area to Conditioner. 2-4. Cable 2226613 IDC Generator Serial link. IDC to Gantry Bulkhead Area then Bulkhead Area to Generator Interface 400 PL2 XJ10. 2-5. Cable 2226623 AWS UPS - Generator Link SB150 - UPS to Gantry Bulkhead Area then Bulkhead Area to Generator Interface 400 PL2 XJ10. 2-6. Cable 2387162 ADS and UPS to Generator: Mid connector to UPS serial I/O: UPS Serial End connector to AWS serial I/O: SB150 Serial A 2-7. Cable 2240227 or 2244615 IDC (COM and Serial) to Generator: 50-pin connector to IDC serial I/O 9-pin connector IDC COM 2 2-8. Cable 2340426 IDC optical fiber port 2-9. Cable 2385966 Ethernet switch port 3: Switch C3. Connects the Control Station to the Gantry CPU. 3. GENERATOR CABINET CABLING 3-1. AC Conditioner Main Distribution Rack XP4 to Conditioner. 3-2. FFDM Main Distribution Link Generator Relay Board 400 PL2 to Main Distribution Rack J9. Chapter 3 Page no. 322 Cables.FM GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements CHAPTER 4 PRE-INSTALLATION SYSTEM REQUIREMENTS The following pages give information required for the planning and preparation of a Senographe system installation. Page no. 323 Chap-Pre-Requirements.fm Chapter 4 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 1. ENVIRONMENTAL REQUIREMENTS 1-1. Atmospheric Pressure Limits (Storage and Operational) Atmospheric pressure Altitude (from sea level) (operation, storage and transportation*) Min. Max. Min. Max. 700 hPa 1060 hPa 0m 3000 m 0 ft 9840 ft * - During transportation a pressurized environment must be used to maintain the atmospheric pressure limits. 1-2. Preventing Thermal Shock to the Detector To prevent thermal shock to the detector, the ambient tempertaure gradient must not exceed the values as specified below. Temperature range Ambient temperature gradient must not exceed 1-3. Less than 0°C 0°C to 40°C Greater than 40°C Less than 32°F 32° to 104°F Greater than 104°F 4.5°C per hour 1.5°C per minute 4.5°C per hour 40.1°F per hour 34.7°F per minute 40.1°F per hour Storage Requirements - temperature and humidity 1-3-1. General requirements - The system includes a detector assembly in its casing, which is sensitive to changes in temperature and humidity, and is water-cooled when in use. - The specified storage requirements assume that the all the equipment remains in its packaging, including the protection for the detector. 1-3-2. Before installation - short term For short-term storage (less than 5 days), refer to the storage requirements table below. Relative humidity (non-condensing) Temperature Min. Max. Min. Max. 5% 95% –20°C 50°C –4ºF 122ºF 1-3-3. Before installation - long term For long-term storage (more than 5 days), it is recommended that the detector assembly is kept in an area with relatively dry and low temperature, or area with air conditioning. For example, relative humidity less than 50%. Chapter 4 Page no. 324 Chap-Pre-Requirements.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 1-4. Operating Requirements - temperature and humidity Relative humidity (non-condensing) Temperature Min. Max. Min. Max. 10% 80% 15°C 35°C 59ºF 95ºF 1-4-1. Air conditioning - Air conditioning must be provided where necessary to ensure that no part of the equipment (including the generator cabinet) operates in an ambient temperature exceeding 35°C (95ºF). - For patient comfort, ambient temperatures of 23°C ± 3°C (73ºF ± 5ºF) are recommended. 1-5. Short Term Shutdown Requirements - temperature and humidity 1-5-1. Shutdown with Conditioner on During evenings and weekends some Operators shutdown the Senographe system via the Control Station; in that case the Conditioner remains switched on, and the environment must be within the following limits. Relative humidity (non-condensing) Temperature Min. Max. Min. Max. 10% 80% 15°C 35°C 59ºF 95ºF 1-5-2. Shutdown with Conditioner off During evenings and weekends some Operators shutdown the Senographe system via the circuit breaker on the wall; in that case the Conditioner is switched off, and the environment must be within the following limits. Relative humidity (non-condensing) Temperature Min. Max. Min. Max. 5% 95% 10°C 50°C 50ºF 122ºF 1-5-3. Air conditioning Air conditioning must be provided where necessary to ensure that no part of the equipment (including the generator cabinet) exists in an ambient temperature exceeding 35°C (95ºF) or below 15°C (59ºF). Page no. 325 Chap-Pre-Requirements.fm Chapter 4 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 1-6. • • Storage of detector after removal After the cooling tank has been filled at installation, serious damage will be caused if the temperature is allowed to fall below freezing point. If after installation you have to remove the detector and store it in an environment which can fall below freezing point, you must ensure that you remove all of the coolant from the detector internal tubes. If the detector is removed from the system and stored again in its original packaging, it can still contain traces of coolant. In this case, the coolant is the limiting factor in the detector storage requirements. It is recommended that the detector is stored between 10°C (50ºF) and 40°C (104ºF). The temperature is allowed to fall to a minimum of -10°C (-14ºF) or rise to a maximum of 50°C (122ºF), for a maximum period of one day. 1-7. Heat Output Chapter 4 Generator Gantry and Control Station Heat output Heat output In standby Max. In standby Max. 0.675 kW 0.9 kW 0.075 kW 0.1 kW 2295 BTU/h 3060 BTU/h 255 BTU/h 340 BTU/h Page no. 326 Chap-Pre-Requirements.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 2. IEC60601-1-2 ELECTROMAGNETIC STANDARDS COMPLIANCE 2-1. General This equipment complies with the IEC60601-1-2 Edition 2 EMC standard for medical devices. The Senographe Equipment or System is suitable for use in electromagnetic environments as defined in the limits and recommendations given in the following tables: • Emission Compliance level and limits (Table 1). • Immunity Compliance levels and recommendations for ensuring that the equipment retains its clinical utility (Tables 2, 3, and 4). Note: This equipment complies with the above EMC standard when used with cables supplied by the manufacturer up to the maximum lengths permitted by the system design specifications. 2-2. Electromagnetic Emission The Senographe system is suitable for use in the specified electromagnetic environment. The purchaser or Operator of a Senographe system must ensure that it is used in an electromagnetic environment as described below: TABLE 1 - ELECTROMAGNETIC EMISSION Emissions Test Compliance Group1 Class A limits Radio-Frequency Emissions CISPR11 Group1 Class A limits Harmonic emissions The Senographe is primarily intended for use in non-domestic environments, and not connected directly to the public mains supply network. It is primarily intended for use in environments (such as hospitals) with a dedicated supply system, and in an X-ray shielded room. The Senographe uses RF energy only for its internal function. The RF emission is therefore very low, and not likely to cause any interference in nearby electronic equipment. Not applicable The Senographe is primarily intended for use in non-domestic environments, and not connected directly to the public mains supply network. Not applicable The Senographe is primarily intended for use in non-domestic environments, and not connected directly to the public mains supply network. IEC 61000-3-2 Voltage fluctuations/ flicker emissions IEC 61000-3-3 Electromagnetic Environment Page no. 327 Chap-Pre-Requirements.fm Chapter 4 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 2-3. Electromagnetic Immunity The Senographe is suitable for use in the specified electromagnetic environment. The purchaser or Operator of the Senographe must ensure that it is used in an electromagnetic environment as described below: TABLE 2 - ELECTROMAGNETIC IMMUNITY - PART 1 Immunity Test IEC 60601-12 Test Level Compliance Level Electromagnetic Environment Electrostatic discharge (ESD) IEC 61000-4-2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors are wood, concrete, or ceramic tiles, or floors are covered with synthetic material and the relative humidity is at least 30 percent. 2 kV for power supply lines 2 kV for power supply lines 1 kV for input/output lines 1 kV for input/output lines Electrical fast transient/burst IEC 61000-4-4 Surge IEC 61000-4-5 Voltage dips, short interruptions, and voltage variations on power supply input lines IEC 61000-4-11 Power frequency (50/60 Hz) magnetic field IEC 61000-4-8 1 kV differential mode 2 kV common mode 0% Un for 5 s Mains power quality is that of a typical commercial and/or hospital environment 1 kV differential mode Mains power quality is that of a typical commercial and/or hos2 kV common pital environment. mode Mains power quality is that of a typical commercial and/or hos0% Un for 5 s pital environment. If the Operator of the Senographe requires continued operation during mains power interruptions, it is recommended that the Senographe is powered from a UPS or battery. Power frequency magnetic fields are at levels characteristic of a typical location in a typical commercial and/or hospital environment. 3 A/m 3 A/m At this disturbance level, the monitor image can present some slight flicker. If this occurs, the monitor can be removed from the vicinity of the low frequency magnetic field source to improve image quality. 1 A/m At this disturbance level, the system is fully operational. Note: These are guidelines. Actual conditions can vary. Chapter 4 Page no. 328 Chap-Pre-Requirements.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements TABLE 3 - ELECTROMAGNETIC IMMUNITY - PART 2 Immunity Test Conducted RF IEC 61000-4-6 Radiated RF IEC 61000-4-3 IEC 60601-12 Test Level 3V 150 kHz to 80 MHz 3 V/m 80 kHz to 800 MHz Compliance Level Electromagnetic Environment [V1 =] 3 V At this disturbance level, the monitor image can present some slight flicker. If this occurs, the monitor can be removed from the vicinity of the electrical field source to improve image quality. [V2 =] 0.3 V At this disturbance level, the system is fully operational. [E1=] 3 V/m At this disturbance level, the monitor image can present some slight flicker. If this occurs, the monitor can be removed from the vicinity of the electrical field source to improve image quality. [E2=] 0.3 V/m 3 V/m 800 MHz to 2.5 GHz [E3=] 3 V/m [E4=] 0.3 V/m At this disturbance level, the system is fully operational. At this disturbance level, the monitor image can present some slight flicker. If this occurs, the monitor can be removed from the vicinity of the electrical field source to improve image quality. At this disturbance level, the system is fully operational. • Field strengths from fixed RF transmitters must be less than the compliance level in each frequency range. At frequencies between 150 kHz to 80 MHz, field strengths must be less than [V2] V/m. Note: Field strengths from fixed transmitters, such as base stations for cellular telephones and land mobile radios, amateur radio, AM and FM radio broadcast, and TV broadcast cannot be estimated accurately. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey must be performed. If the measured field strength exceeds the RF compliance level above, monitor the Senographe to check normal operation in each use location. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the Senographe. • Interference can occur in the vicinity of equipment marked with the following symbol: . • No portable or mobile RF communications equipment can be used closer to any part of the Senographe, including cables, than the recommended separation distance calculated from the equation appropriate to the frequency of the transmitter. See Table 4. Note: These are guidelines. Actual conditions can vary. Page no. 329 Chap-Pre-Requirements.fm Chapter 4 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 2-4. Recommended Separation Distances for Portable and Mobile RF Communications Equipment IEC 60601-1-2 TABLE 4 - RECOMMENDED SEPARATION DISTANCES Frequency of Transmitter Equation 150KHz to 26 MHz d =[ 3,5 ] P V2 26 MHz to 80 MHz d =[ 3,5 ] P V2 80 MHz to 800 MHz d =[ 3,5 ] P 800 MHz to 2.5 GHz d =[ 7 E2 E4 ] P Rated Power of Transmitter (watts) DISTANCE DISTANCE DISTANCE DISTANCE (meters) (meters) (meters) (meters) 10 mW 1.2 1.2 1.2 2.3 100 mW 3.8 3.8 3.8 7.3 1 12 12 12 23(*) 10 38 38 38 73 100 120 120 120 230 • For transmitters rated at a power not listed above, the recommended separation distance (d, in meters) can be estimated using the equation in the corresponding column. Where P is the power rating of the transmitter in watts (W) according to the transmitter manufacturer. • (*) For example, a 1 W mobile phone (800 MHz to 2.5 GHz carrier frequency) must be no closer than 23 meters from the Senographe to avoid image interference risks. • Using the recommended distance as determined from Table 4, between 150KHz and 2.5 GHz, some slight disturbance can be observed at image level. The disturbance to the image cannot be confused with a medical pathology, and the equipment retains its medical utility. Note: These are guidelines. Actual conditions can vary. 2-5. • Use Limitation External components: The use of accessories, transducers, and cables other than those specified can result in the degraded Electromagnetic compatibility of the Senographe. Chapter 4 Page no. 330 Chap-Pre-Requirements.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 2-6. Installation Requirements and Environmental Control • In order to minimize interference risks, the following requirements apply. 2-6-1. Cable Shielding & Grounding • All interconnecting cables to peripheral devices must be shielded and properly grounded. Use of cables not properly shielded and grounded can result in the equipment causing radio frequency interference. 2-6-2. Separated Power Supply Distribution Panel & Line • This product complies with the radiated emission limits of the CISPR11 Group1 Class A standard. • The Senographe is primarily intended for use in non-domestic environments, and not connected directly to the public mains supply network. It is primarily intended for use in environments (such as hospitals) with a dedicated supply system, and in an X-ray shielded room. • To avoid interference in the event that the Senographe is used in a domestic environment (in a doctors office, for example), it is recommended that it must be connected to a separate AC power distribution panel and line, and it must be installed in an X-ray shielded room. 2-6-3. Subsystem & Accessories Power Supply Distribution • All components, accessories, subsystems, and systems which are electrically connected to the Senographe must have AC power supplied by the same power distribution panel and line. Note: - You can not connect together different electrical devices and supply them by different AC power distribution lines. - In order to avoid interference, all components and accessories connected to the Senographe must be connected to the same AC power distribution panel. This AC power distribution panel which is itself supplied by a single power line. 2-6-4. Stacked Components & Equipment • The Senographe must not be used adjacent to or stacked with other equipment. If adjacent or stacked use is necessary, the Senographe must be monitored to ensure that normal operation occurs in the configuration in which it is used. 2-6-5. Static Magnetic Field Limits • In order to avoid interference on the Senographe system, static field limits from the surrounding environment are specified. • Static field is specified as less than 1 Gauss in the Examination room (Gantry room), and in the Control Area (for all Subsystems). • Static field is specified as less than 3 Gauss in the Technical Room. 2-6-6. Electrostatic Discharge Environment & Recommendations • In order to reduce electrostatic discharge interference, a charge dissipative floor must be installed to prevent charge accumulation. • The dissipative floor material must be connected to the system reference ground, if applicable. • Relative humidity must be maintained above 30 percent. Page no. 331 Chap-Pre-Requirements.fm Chapter 4 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 3. NOISE 60 dBA at 1 m (3’3”). 4. STRUCTURAL REQUIREMENTS 4-1. Ceiling Requirements The top of the Senographe system Tube Head can travel up to three different discrete maximum heights. The Tube Head maximum height is determined by setting one of the three discrete Lift Travel Limit Ranges on the Senographe system. Table 5 below summarizes the minimum ceiling height required corresponding to the three different Lift Travel Limit Ranges. Illustration 2 on page 342 shows the dimensions of the Gantry. TABLE 5 - RECOMMENDED MINIMUM CEILING HEIGHTS Lift Travel Limit Range Corresponding Tube Head Height Recomended Minimum Ceiling Height * Corresponding Bucky Plane Maximim Height 650 mm 2230 mm (87.80") 2300 mm (90.55") 1295 mm (50.98") 750 mm 2330 mm (91.73") 2400 mm (94.49") 1395 mm (54.92") 850 mm (default setting) 2430 mm (95.67") 2500 mm (98.43") 1495 mm (58.86") * - The recommended minimum ceiling height assumes that there is a marginal gap of 70 mm between the top of the Tube Head and the ceiling. If necessary, you can reduce the marginal gap to 10 mm. The lowest possible ceiling that can accommodate a Senographe system is therefore 2240 mm. The distance between the plane of the Bucky and the top of the Tube Head is fixed at 935 mm (36.81 inches). Table 5 also shows the corresponding maximum Bucky plane height for each of the three different Lift Travel Limit Ranges. You must determine: • whether the maximum Bucky plane height corresponding to your ceiling height is acceptable for your customer base • if you have to make appropriate allowances such as the use of chairs for tall patients 4-2. Wall Requirements The hospital must take special precautions regarding X-ray protection in the examination room walls. See Planning for Radiation Protection on page 339. 4-3. Floor Requirements The Gantry and Control Station must be anchored to the floor. The Generator cabinet is normally placed on the floor, but must be anchored in seismic areas. The floor must be stable and flat, and sufficiently strong to accept masses as defined below without distortion beyond the tolerance given: 1. Gantry: • The worst case mass of the complete Gantry (with Stereotaxy option) is 418 kg (921.5 lbs). • The bearing surface of the base plate is 0.42 m² (4.52 sq. ft.). • The Gantry is provided with three or five anchoring points (refer to Anchoring Inserts on page 354.). Chapter 4 Page no. 332 Chap-Pre-Requirements.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements • The floor surface must remain horizontal and flat within ±2.5 mm per meter (±1/10 inch in 39 inches) after installation of the Gantry. 2. Control Station: • The worst case mass of the complete Control Station is 217 kg (478.4 lbs). • The bearing surface of the base plate is 0.28 m² (3 sq. ft.). • The Control Station is provided with four anchoring points (refer to Anchoring Inserts on page 354.). • The floor surface must remain horizontal and flat within ±2.5 mm per meter (±1/10 inch in 39 inches) after installation of the Control Station. The customer is responsible for the structural analysis of the floor and the proposed mounting method. The customer must hire a structural engineer to design and approve the mounting method, and provide GEMS with an engineering report. If the results of the structural analysis require stronger anchoring inserts the defaults supplied in Anchoring Inserts on page 354, the customer must inform GEMS. Flooring consists of all materials above the structural floor support including subflooring and equipment support/mounting. The flooring requirements and recommendations are as follows: • Flooring materials must support the Senographe system equipment mass, refer to Dimensions and Masses on page 341. • Floors must support the equipment and any transport device used to move the equipment. • Flooring throughout the system including X-ray Room must be in accordance with local and national codes. Page no. 333 Chap-Pre-Requirements.fm Chapter 4 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 4-4. Seismic Requirements For each unit, the unit mass and the position of the center of gravity is provided in Dimensions and Masses on page 341, to allow compliance with local codes or regulations. Sites that require seismic anchoring must have a site architect and engineer review the response spectra and/or Uniform Builders Code (UBC) for their location. 4-4-1. X-Floor Requirements When Using provided Floor Anchors The maximum load pull tension per provided anchor was calculated assuming: • Maximum bolt load pull tension at each bolt, refer to Anchoring Inserts on page 354. • Anchors installed to the required minimum floor thickness, refer to Anchoring Inserts on page 354. 4-4-2. X-Pan Type Floor Construction Requirement For Pan type floor construction, steel channels must be designed by a local structural engineer or architect to span floor joists. 4-4-3. Generator Cabinet In seismic areas, provision must be made for securing the Generator to the floor, or provision must be made to secure it in place. For example, encircle the unit with a nylon belt secured to wall anchors. 4-4-4. Independent Radiation Shield In seismic areas, if the optional independent radiation shield is present, it must be anchored to the floor, or provision must be made to secure it in place. For example, encircle the unit with a nylon belt secured to wall anchors. 4-4-5. Gantry Two additional anchoring holes exist to improve the anchoring: refer to Gantry Baseplate Template on page 356. 5. ELECTRICAL REQUIREMENTS 5-1. CERTIFIED ELECTRICAL CONTRACTOR STATEMENT ! Notice: All electrical installations that are preliminary to positioning of the equipment at the site prepared for the equipment must be performed by licensed electrical contractors. In addition, electrical feeds into the Power Distribution Unit must be performed by licensed electrical contractors. Other connections between pieces of electrical equipment, calibrations, and testing must be performed by qualified GE Medical personnel. The products involved (and the accompanying electrical installations) are highly sophisticated, and special engineering competence is required. In performing all electrical work on these products, GE will use its own specially trained Field Engineers. All of GE electrical work on these products will comply with the requirements of the applicable electrical codes. The purchaser of GE equipment must only utilize qualified personnel to perform electrical servicing on the equipment. That is GE Field Engineers, personnel of third-party service companies with equivalent training, or licensed electricians. Chapter 4 Page no. 334 Chap-Pre-Requirements.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 5-2. Room Power Supply WARNING Responsibility of customer’s electrician Responsibility of GEMS FE Line Supply Cable ! Notice: Line power to the Senographe system must be supplied through a suitable circuit breaker (see section 5-8 Main Circuit Breaker on page 337). The circuit breaker must be accessible to allow it to be opened rapidly in case of emergency. An indicator light must be provided to indicate that power is present. The diagram given here outlines a suitable supply system and indicates items to be provided and installed by the customer electrician. Refer to the following sections for more information. Legend: - PDB: Power distribution box supplying AC power to the Senographe system equipment. AC supply - DCB: Differential circuit breaker (thermomagnetic). PDB - MC: Main contactor. Manual switch to be accessible for emergency use. DCB - PB: Remote control for main contactor; ON/ OFF impulse push-buttons, lockable ON/OFF, with indicator lights (Red = ON, Green = OFF). To be located near access door, 1.5 m MC (59 inches) above the floor. - LMP1: Red power presence indicator light (continuous glow or flashing), located above access Gnd FW door; bulb 30 V, 25 W max. - Line Supply Cable, which comprises of two supPB ply wires (FW) and a ground cable (Gnd) — 3 x 5.32 mm². LMP1 The Line Supply Cable from the Generator Generator Cabinet line input must be internally and permanently connected to the hospital power distribution box, and cannot be externally connected to the power distribution box via a plug. The internal and permanent connection must be made in a way such that the Line Supply Cable can only be disconnected by use of a tool. - Generator Cabinet. 5-2-1. Lockable LOTO Enabled Power Sources Lockable LOTO enabled power sources must be made available to the following: • the Line Supply Cable going from the room Mains Distribution Panel and the Generator • the Status Lamps power cables going from the room door to the Generator Examples of LOTO enabled lockable power sources include those with lockable disconnecting switches (see example 1 and example 2 in Illustration 1), or lockable breakers (see example 3 in Illustration 1). Page no. 335 Chap-Pre-Requirements.fm Chapter 4 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements ILLUSTRATION 1 - EXAMPLES OF LOCKABLE LOTO ENABLED POWER SOURCES Example 2 Example 1 5-3. • • Example 3 Line Voltage Specifications Single phase input voltages (phase/neutral or phase/phase): 200/208/220/240 V (±10%). Maximum line current of the system: 42 A at 180 VAC, based on maximum input voltage (30 kV) and output current (100 mA) of the tube housing assembly. The maximum line current corresponds to the use of the technique factors 30 kV, Mo track, large focal spot and 100 mAs or more. CAUTION 380 VAC or 415 VAC coupling which was possible with Senographe 2000D is not possible with the Senographe DS system. If you choose this coupling, you will destroy the Gantry power supply. 5-4. • 50 Hz or 60 Hz (±1 Hz). 5-5. • • • • Line Frequency Specifications kVA Load Characteristics Maximum power in standby: 1.5 kVA. Maximum instantaneous power (during exposures, up to 6 seconds) 9 kVA. Power factor: 0.6. Line current crest factor: 1.7 at 200 V. 5-6. Line Impedance The apparent resistance of the mains supply RL must be less than that which would cause a voltage drop of 6% at the maximum power load of 9 kVA. Refer to the table below for relevant values: Nominal voltage (V ac) 200 208 220 240 Maximum impedance RL (ohms) 0.28 0.30 0.34 0.40 Chapter 4 Page no. 336 Chap-Pre-Requirements.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 5-7. Line Supply Cable The Line Supply Cable provides AC power from the hospital Mains Distribution Panel to the Generator. The Line Supply Cable comprises of two supply wires (FW) and a ground cable (i.e. 3 x AWG 10 (5.32 mm²)) with the following actual/usable lengths: - Total length = 7 m (23’) - Usable length = 6.5 m (21’-4”) 5-7-1. Obtaining a Line Supply Cable The Line Supply Cable must be ordered from the price book so that it is supplied with the Senographe System. Please note that a different price book reference exists for China and the rest of the world. 5-8. Main Circuit Breaker Circuit breaker sizes for Europe: • From 200 V up to 240 V: circuit breaker: In = 32 A (type D) magnetic I = 12In ±20%; with differential trigger: 30 mA (waveform pulsed). For circuit breaker sizes and supply conductors for the US market, refer to Section 517-71(a) and Section 517-73(a) (Item 1, 2) of NEC-1993 (see below). • The branch circuit used must be rated 30 A or less. • NEC 1993 Section 517-73 (a) Item 1: The current capacity of supply branch circuit conductors and the current rating of overcurrent protective devices must not be less than 50% of the momentary rating or 100% of the long-time rating, whichever is greater. • NEC 1993 Section 517-73 (a) Item 2: The current capacity of supply feeders and the current rating of overcurrent protective devices supplying two or more branch circuits supplying X-ray units must not be less than 50% of the momentary demand rating of the largest unit plus 25% of the momentary demand rating of the next largest unit plus 10% of the momentary demand rating of each additional unit. Where the X-ray units are used for simultaneous biplane examinations, the supply conductors and overcurrent protective devices must be 100% of the momentary demand rating of each X-ray unit. Page no. 337 Chap-Pre-Requirements.fm Chapter 4 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 6. DOOR LIGHTS AND SAFETY SWITCH To meet safety and regulatory requirements, access to rooms in which X-ray equipment is installed must be controlled by warning lights and safety switches. The Generator provides facilities to meet these requirements. The diagram below shows the circuits used, and indicates items required for supply by the customer. See also section 5-2 above for the power presence indicator LMP1. GENERATOR RACK Board 200PL4 CUSTOMER-SUPPLIED ITEMS AC or DC 30 V max K1 XJ1 Seno ON lamp LMP2 AC or DC 30 V max K2 XJ2 X-ray ON lamp LMP3 K3 ~ XJ3 24 V AC external power Room door switch Contacts open when door opens Note: The load current ratings of relays K1 and K2 are 5 A/30 V AC or DC. For safety reasons, the electrical source for the K1 and K2 lamps (i.e. Seno ON and X-ray ON lamps) must be no more than 30 V. You cannot use a 250 V source under any circumstances. The relay K3 must be supplied with 24 V ac. 7. ROOM LIGHTING In order to obtain a room brightness value of 100 lux or less for correct viewing of monitor images, the room lights must be equipped with a dimmer switch. Shades and/or drapes must be fitted to windows. Chapter 4 Page no. 338 Chap-Pre-Requirements.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 8. PLANNING FOR RADIATION PROTECTION 8-1. Radiation Protection - General Because the X-ray equipment produces radiation, the purchaser must take special precautions or make special site modifications. The General Electric Company does not make specific recommendations regarding radiation protection. It is the purchasers responsibility to consult a radiation physicist for advice on radiation protection in X-ray rooms. 8-2. Radiation Shielding - Operators Operators must remain in an area protected against radiation when X-ray exposures are made. This means that X-ray controls (X-ray Console) must be mounted in such a way that they can only be used while the Operator remains in a protected area. To meet European Regulations (Directive Euratom 96 29), the limit value for the whole-body equivalent dose must not exceed 20 mSv per year. For other non-European countries, consult your local regulations for the dose limit value. The X-ray Console must be mounted behind either an integrated radiation shield or behind a free-standing radiation shield. • The integrated radiation shield supplied with the Senographe system is 700 mm wide, and attached directly to the Control Station. Two versions of the integrated radiation shield exist, as follows: - Lemerpax, which is 9 mm (0.35”) thick and has a lead thickness equivalence of 0.3 mm (0.012”) at 49 kV. - Mavig, which is 6 mm (0.24”) thick and has a lead thickness equivalence of 0.5 mm (0.020”) at 35 kV. Note: The Mavig radiation sheild is not available in China. In the case of the integrated radiation shield, the X-ray Console must be mounted on the Control Station, behind the integrated radiation shield. • For installations that require wider shields or shields with a greater lead thickness equivalence than that provided by the integrated radiation shield, GE Healthcare provide free-standing radiation shields with widths of 705, 1470, or 2235 mm (27.76, 57.88, or 88 inches). These optional radiation shields have a lead thickness equivalence of 1 mm (0.04") (see Illustration 5 on page 345). In this case, the X-ray Console must be mounted on the framework of the free standing radiation shield, behind the radiation shield. Other forms of protection can be used, in particular structural or custom-made shielding. Note: If other forms of protection are used, the Senographe system is still delivered with either an integrated or free-standing radiation screen. Note: Radiation Shields supplied by General Electric have toughened glass. If the customer requires a separate free-standing Radiation Shield, it must be made with toughened glass. Page no. 339 Chap-Pre-Requirements.fm Chapter 4 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 9. PLANNING FOR STORAGE 9-1. Temporary Storage in the Hospital ! Notice: There is normally a short delay (e.g., overnight) between the delivery of the equipment and its installation. If this delay is not short (more than two days), it is essential that a suitable storage room is available to receive the equipment in its crates. Refer to section 1 Environmental Requirements for information on the environment required. 9-2. Packing Information The table below lists the main dimensions and masses of shipping crates. TABLE 6 - SHIPPING DIMENSIONS AND MASSES. Item Crate1 Dimensions in mm (inches) Mass in Depth Width Height kg (lbs) 2066 (81.34) 848 (33.39) 2292 (90.24) 641 (1410.2) Crate 1 includes the Gantry and the Generator Cabinet and the ramp for removing the Gantry, Generator and Control Station Crate 2 1110 (43.70) 770 (30.31) 1850 (72.83) 210.5 (464.07) for truck transportation without side covers and lid 223.5 (492.73) for plane/boat transportation with side covers and lid Crate 2 includes the Control Station Crate 3 872 (34.33) 2270 (89.37) 260 (10.24) 104.4 (229.68) Crate 3 includes the box containing the Detector. (20 kg, D=766 (30.16) , W= 840 (33.07), H =654 (25.39) and the Radiation Screen in its protective packaging Crate 4 720 (28.35) 1300 (51.18) 1975 (77.76) 147 (323.4) * Crate 4 includes the Accessories Cabinet, which includes the LCD Monitor, X-ray Console and all the Accessories (boxed) . * - The contents can vary, and the mass can be slightly different to 147 kg. Chapter 4 Page no. 340 Chap-Pre-Requirements.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 9-3. Constraints for Moving the Equipment Into the Room The minimum dimension of the entry door to move in the (uncrated) Gantry on its wheels with a 61.5 mm (2.40 inches) radius are: • door opening at least 700 mm (27.6 inches) wide. • height of 2020 mm (79.53 inches) with Gantry covers. • height of 1897 mm (74.69 inches) without Gantry covers. Note: If the hospital doors are less than height of 2020 mm (79.53 inches) high, prepare time to remove the Gantry covers during the delivery of the Senographe System. You will need to remove the Gantry covers so that you can move the Gantry under the doors. Note: In cases where a Senographe system is not installed on the ground floor of a building, you must consider the size of the hospital elevators. In cases where hospital elevators are small, you will need to disconnect the Generator from the Gantry and move them separately. The minimum depth of hospital elevators must be slightly larger than 1273 mm (50.1 inches) in order to be able to move the Gantry. 10. ROOM LAYOUT PLANNING 10-1. Dimensions and Masses Refer to the following pages for more information on major components. TABLE 7 - SYSTEM COMPONENT DIMENSIONS AND MASSES. Component Depth mm (inches) Width mm (inches) Height mm (inches) Mass kg (lbs) Gantry (with Stereotaxy Positioner) 1273 (50.1) 616 (245.25) Required space: 1842 (72.5) 1930 (76) to 2430 (95.67) 418 (921.5) Generator Cabinet 437 (17.2) 640 (25.2) 1330 (52.5) 180 (396.8) 19" monitor (default) 98 (3.9) 410 (16.15) 340 (13.4) 8 (17.6) 3 MP 21.2" monitor (option) 97 (3.8) 500 (19.7) 376 (14.8) 7.4 (16.3) X-ray Console 180 (7) 550 (22) 85 (3.5) 1.6 (3.5) Radiation Shield (Lemerpax) 9 (0.35) 700 (27.5) 1479 (58.5) 26 (57.3) Radiation Shield (Mavig) 6 (0.24) 700 (27.5) 1150 (45.3) 15 (33.1) Control Station without radiation shield, monitor, and X-ray Console 400 (15.75) 710 (27.9) 2225 (87.5) 181.2 (399.5) Page no. 341 Chap-Pre-Requirements.fm Chapter 4 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements ILLUSTRATION 2 - GANTRY DIMENSIONS - MM (INCH) Maximum Height 2430 2447(94.67) (96.4) 1930 (76) Z CG 1842 (72.5) 1273 (50.1) 630 (24.8) CG Gantry base plate 788 (31.0) X Z 1842 (72.5) Y Center of Gravity (CG): X = 325 (12.8) Y = 3 (0.12) Z = 1024 (40.3) All measurements shown as: mm (inches) • Anchor Points for the Gantry Refer to Anchoring Inserts on page 354. Chapter 4 Page no. 342 Chap-Pre-Requirements.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements ILLUSTRATION 3 - GENERATOR CABINET DIMENSIONS 437 (17.2) 640 (25.2) CG CG 1350 (53.2) 554 (21.8) CABLE ENTRY SPACE FOR CABLE STORAGE POWER CONTROL BUTTONS Page no. 343 Chap-Pre-Requirements.fm All measurements shown as: mm (inches) Chapter 4 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements ILLUSTRATION 4 - CONTROL STATION DIMENSIONS - MM (INCHES) 2225 (87.5) * Center of Gravity (origin at bottom, left, back) (with Lemerpax Radiation Shield): X = 213 (8.4) Y = 358 (14.1) Z = 654 (25.75) Cable entry from left of the Control Center of Gravity Z Y X Origin Origin 400 (15.75) 710 (27.9) Control Station base plate 400 (15.75) * - Control Station height with: Mavig Radiation Shield is 1896 (74.7) Lemerpax Radiation Shield is 2225 (87.5) All measurements shown as: mm (inches) 710 (27.9) • Anchor Points for the Control Station Refer to Anchoring Inserts on page 354. Chapter 4 Page no. 344 Chap-Pre-Requirements.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements Single Configuration: Optional radiation shield 275 (10.8) 720 (28.4) 690 (27.2) ILLUSTRATION 5 - DIMENSIONS OF OPTIONAL RADIATION SHIELDS Double Configuration: Optional radiation shield plus one optional radiation screen extension on one side (left or right) Triple Configuration: Optional radiation shield plus one optional radiation screen extension on each side Ordering: Optional radiation shield: S30321MM (2234536) Optional radiation shield extension (never ordered alone): S30311CW (2166641) All measurements shown as: mm (inches) Page no. 345 Chap-Pre-Requirements.fm Chapter 4 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 10-2. Layout Constraints for Positioning Gantry, Generator, and Control Station The layout and positioning of the Gantry, Generator, and Control Station depend on various factors summarized below: • Safety - SA1: Minimum "trapping zone" safety clearance (as defined by CEI 60601-1 3rd Edition Trapping Zone) around the motorized moving parts of the Gantry is 500 mm. Therefore, the minimum distance between the extreme positions of the Tube Head and any objects (e.g. wall or Generator) must be a minimum of 500 mm. - SA2: The Stop motion buttons are located on both sides of the Gantry, relatively far away from the Control Station. Access to these buttons from the Control Station must be easy going around the Control Station by the left or by the right. - SA3: Protection of the Operator, such that the X-ray dose level they receive is within a safe level (as defined by Directive Euratom 96 29). X-rays emitted from the Tube Head are attenuated to a safe level when the default radiation screen supplied with the system is at least 1000 mm from the Tube Head at an angle of 0°. • Serviceability All sides of the three components need access for servicing. - SE1: Gantry: 200 mm between the rear edge of the Gantry baseplate and the wall. - SE2: Generator: 100 mm on either left/right side of the Generator where the cables can exit. The two power control buttons on the front side must be facing outwards away from the wall. The Generator is on wheels, so it can easily be moved during servicing. - SE3: Control Station: A clearance of 300 mm from the Control Station baseplate right edge, so access to the UPS, IDC and ADS cables are possible. • System Use - SU1: Generator: 100 mm at the rear side to allow uninhibited air flow. - SU2: Control Station: The path of the Rotative Arm must be such that the LCD Monitor does not come into contact with the Tube Head, wall, or other objects. • Clinical Use - CU1: Control Station: A clearance of 700 mm from the Control Station baseplate front edge, so that the Operator has a clearance of 500 mm with a fully expanded keyboard. - CU2: Control Station: A clearance of 50 mm from the Control Station baseplate left edge, so that the Operator can open the integrated CD-ROM. - CU3: Easy access to the patient area. Stretchers and other mobile hospital equipment must be able to reach the table quickly. - CU4: Clinicians in the patient area must be able to communicate easily with operators and others in the control area. - CU5: Operators must have easy access to the X-ray Console. However, the X-ray Console and ancillary handswitches must be positioned so that the operator can only take exposures while behind the radiation shield. Note: The distances given above correspond to a minimum, but it remains the responsibility of the local installation services team to ensure that the country regulations are followed. For example, in the United States the Labor Occupational Safety and Health Administration (OSHA) regulations must be taken into account, such that an Egress of 28" (711 mm) is respected. Chapter 4 Page no. 346 Chap-Pre-Requirements.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 10-2-1. Ancillary Equipment Consult hospital personnel regarding additional space requirements for hospital equipment such as storage cabinets, sinks, and crash cart. 10-2-2. Positioning of the LCD Monitor on the Control Station By default, the rotative arm that supports the LCD monitor is installed on the right-hand side of the Control Station. This is because, for most Operators (who are right-handed), it is more convenient to have the mouse/trackball on the right-hand side. However, the following situations require the rotative arm that supports the LCD monitor to be moved on the left-hand side of the Control Station: • the rare occasion where all or the majority of operators at the customer site are left handed, and the layout of the room allows the rotative arm to be installed on the left-hand side • the room that hosts the Scenographe system does not permit the Control Station to have the LCD monitor on the right-hand side, due to either limited space or intrusive objects such as doors or pillars When reviewing the room that will host the Senographe system, you must determine whether the LCD monitor must be installed on the left-hand side of the Control Station. 10-2-3. Generic Constraints Overview The diagram below generically highlights the constraints mentioned above, which you must consider when planning a room layout. SU1 SE1 SE2 SA2 SU1 1 4 SA2 SA1 SA1 CU2 2 3 5 6 7 SA3 CU1 SU2 SE3 To door switch and lights. 1. Generator Cabinet. 2. Gantry. 3. Control Station with Radiation Shield. 4. AC power input through power distribution box (supplied by customer). 5. Broadband connection for Insite (supplied by customer). 6. Hospital network connection (supplied by customer). 7. Telephone connection for operators. After the room layout is decided, suitable provision (plinths, under-floor conduits, etc.) must be made for passing cables and conduits. Page no. 347 Chap-Pre-Requirements.fm Chapter 4 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 10-2-4. Layout Examples The following illustrations provide some example layouts which adhere to the constraints listed above. Each layout example contains a non-USA and a USA version, where the USA versions adhere to OSHA Egress safety standard of 28" (711 mm). Note: Ensure that the room layout is adapted to the cable length constraints as listed in the table below and as summarized in section 10-4. Cable/Harness Length Gantry to Control Station cables in Harness 1 4.8 m (15.75") Gantry to Generator cables in Harness 2 3.8 m (14.9") Generator to Control Station: X-ray Console Cable The X-ray Console cable is integrated within the two harnesses. If the X-ray Console cable is separated from the harnesses its total usable length is 10 m (32.8"). Note: If a separate radiation screen is used instead of the integrated radiation screen, the Control Station must positioned so that the LCD Monitor cannot collide with the integrated radiation screen. Note: If the room size is small such that it restricts the positioning of the Control Station so that it is close to a wall or separate radiation screen, the Rotative Arm securing the LCD Monitor can be adjusted so that it does not move. Chapter 4 Page no. 348 Chap-Pre-Requirements.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements ILLUSTRATION 6 - NON RECUMBENT PATIENTS, LCD ON THE LEFT (NON USA) ILLUSTRATION 7 - NON RECUMBENT PATIENTS, LCD ON THE LEFT (USA) Page no. 349 Chap-Pre-Requirements.fm Chapter 4 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements ILLUSTRATION 8 - NON RECUMBENT PATIENTS, LCD ON THE RIGHT (NON USA) ILLUSTRATION 9 - NON RECUMBENT PATIENTS, LCD ON THE RIGHT (USA) Chapter 4 Page no. 350 Chap-Pre-Requirements.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements ILLUSTRATION 10 - RECUMBENT PATIENTS, CONTROL STATION IN FRONT OF TUBE HEAD (NON USA) ILLUSTRATION 11 - RECUMBENT PATIENTS, CONTROL STATION IN FRONT OF TUBE HEAD (USA) Page no. 351 Chap-Pre-Requirements.fm Chapter 4 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements ILLUSTRATION 12 - RECUMBENT PATIENTS, CONTROL STATION BEHIND TUBE HEAD (NON USA) ILLUSTRATION 13 - RECUMBENT PATIENTS, CONTROL STATION BEHIND TUBE HEAD (USA) Chapter 4 Page no. 352 Chap-Pre-Requirements.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements ILLUSTRATION 14 - IDEAL ROOM LAYOUT IF THERE ARE NO SPACE RESTRICTIONS (USA) In the ideal room layout (for USA), the orientation of the Control Station, Generator, and Gantry are all positioned in a way, such that: • the 28" egress clearance is everywhere • all the cable groups are along one wall and kept out of the way, preventing damage to them or having them become a trip hazard • full use of the Rotative Arm for LCD monitor is permitted Page no. 353 Chap-Pre-Requirements.fm Chapter 4 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 10-3. Anchoring to the Floor 10-3-1. The Positioning Templates The installation kit supplied with the equipment includes two templates printed on white paper. These templates assist with the layout of the Gantry and Control Station, and positioning the anchors. ! Notice: Remember to respect the minimum distances required between the Gantry and the Control Station or radiation screen to allow access to the stop motion buttons. 10-3-2. Anchoring Inserts Please ensure that the load rating for the floor is enough to withstand the mass of the Gantry, the Control Station, and the Generator: refer to Floor Requirements on page 332. 10-3-2-1. Anchoring Inserts Provided with the Senographe System (only for non-seismic areas) The recommendations listed in the table below correspond to the anchoring inserts that are supplied with the Senographe system. You must choose to use different anchoring inserts if your floor thickness is less than 120 mm and/or if you are installing the Senographe system in a seismic area. Anchoring holes in the floor Gantry baseplate Control Station baseplate (see Illustration 15) (see Illustration 16) Number of holes in the plate 3 4 Diameter of the hole in the plate 11 mm 14 mm Hole diameter in the floor 10 mm 16 mm Hole depth in the floor Min: 70 mm Max: 110 mm Min: > 90 mm Provided inserts Fischer FUR 10x100SS External diameter of 10 mm for a screw with 7 mm diameter Hilti HAM M10x80 External diameter of 16 mm for a screw with 10 mm diameter Maximum bolt load pull tension (at each bolt) 150 daN 580 daN Minimum floor thickness 120 mm 120 mm Recommended tightening torque 10.1 Nm 45 Nm on concrete 20 Nm on masonary If you use different anchoring inserts to those supplied, you must use the recommendations corresponding with those anchoring inserts and not those listed in this table. Your local structural engineer is responsible for evaluating the recommendations of third-party anchoring inserts. Chapter 4 Page no. 354 Chap-Pre-Requirements.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 10-3-2-2. Anchoring Inserts Not Provided with the Senographe System (for seismic areas) The following tables provide the recommended anchoring inserts seismic areas. Due to the differing availability of Hilti bolts in different contentinents, the following tables provide different bolt recommendations. The minimum floor thickness required varies according to the bolts used. USA - Hilti Kwick Bolt III Anchoring holes in the floor Gantry baseplate (see Illustration 15) Gantry baseplate additional anchoring holes for seismic areas Control station baseplate (see Illustration 16) (see Illustration 15) Number of holes in the plate 3 2 4 Diameter of the hole in the plate 11 mm 11 mm 14 mm Recommended inserts Hilti Kwik Bolt III 3/8" Hilti Kwik Bolt III 3/8" Hilti Kwik Bolt III 3/8" Hole diameter in the floor 9.5 mm (3/8”) 9.5 mm (3/8”) 9.5 mm (3/8”) Hole depth in the floor 64 mm (2 ½”) 64 mm (2 ½”) 64 mm (2 ½”) Minimum floor thickness 95 mm (3 ¾”) 95 mm (3 ¾”) 95 mm (3 ¾”) Maximum bolt load pull tension (at each bolt) 490 daN 490 daN 490 daN Recommended tightening torque 34 Nm 34 Nm 34 Nm Gantry baseplate Gantry baseplate additional anchoring holes for seismic areas Control station baseplate EUROPE - Hilti HSA Bolts Anchoring holes in the floor (see Illustration 15) (see Illustration 16) (see Illustration 15) Number of holes in the plate 3 2 4 Diameter of the hole in the plate 11 mm 11 mm 14 mm Recommended inserts HSA M10 x 90 - 20 / 25 HSA M10 x 90 - 20 / 25 HSA M10 x 90 - 20 / 25 Hole diameter in the floor 10 mm 10 mm 10 mm Hole depth in the floor 70 mm 70 mm 70 mm Maximum bolt load pull tension (at each bolt) 490 daN 490 daN 490 daN Minimum floor thickness 105 mm 105 mm 105 mm Recommended tightening torque 34 Nm 34 Nm 34 Nm Page no. 355 Chap-Pre-Requirements.fm Chapter 4 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements ILLUSTRATION 15 - GANTRY BASEPLATE TEMPLATE Chapter 4 Page no. 356 Chap-Pre-Requirements.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements ILLUSTRATION 16 - CONTROL STATION BASEPLATE TEMPLATE Page no. 357 Chap-Pre-Requirements.fm Chapter 4 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 10-4. Interconnecting Cables Path and Length The diagram below is provided to help planning cable runs between subsystems. Codification color on the illustration: Black = Harness, Shipped with the system Red = Power AC supply (Line Supply Cable) (GEMS supplies a usable length = 6.5 m (21’-4”) cable) Blue = Door light and switch (local adaptation) Green = Insite connection Purple = X-ray Console Cable CAUTION Cables between Generator and Gantry and X-ray Console are fragile: Protect these cables in a cable housing or ensure that the cable path is safe. Insite connection Harness 2 : 4.8 m 15.75' Harness 1 : 3.8 m 14.9' 10 m 32.8' (*) Door switch Door Warning Lights Gantry A Generator Cabinet Customer supplied AC mains distribution panel X - ray Console AC Supply A’ Control Station Optional 60 m 197" All cable lengths indicated are usable lengths External network hub * - The X-ray Console cable is integrated within harness 2, and cable tied alongside harness 1. It can be separated from the harnesses, where its total usable length is 10 m (32.8') (between A and A’). Chapter 4 Page no. 358 Chap-Pre-Requirements.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements 11. INSITE CONNECTION A broadband Internet connection or a Dedicated Service Network must be provided for access to Insite services. There are currently three main methods of providing this connection. Either Virtual Private Network (VPN) tunneling on a broadband Internet connection, or a Dedicated Service Network as follows: • Site to Site VPN (GE Solution) : using an analog or digital broadband router supplied by GE. • Site to Site VPN (Customer Solution) : using an analog or digital broadband router and infrastructure supplied by the customer. • Dedicated Service Network provided by the country local health service (if available) (e.g. NHSnet/ N2/N3 in the UK, SJUnet in Sweden, and Sescam in Spain). More information can be found in the Insite Pre-Installation Manual 2327624-100 and the Broad Band (BB) Solutions Catalogue. You can download this from the OTR & Sales section at http://supportcentral.ge.com/products/sup_products.asp?prod_id=24026 (GEMS SSO login credentials required). Note: The Insite Pre-Installation Manual and the BB Solutions Catalogue are only available via the GEMS Intranet. If a customer require these documents then GEMS personnel can provide the customer with these documents at request. In the Americas region, only the Site to Site VPN (Customer Solution) is possible. 12. NETWORKING CONNECTIONS • The Control Station and any optional equipment provided are to be connected together as a hospital network. • Before installation, the following information must be obtained for each network host so that it can be addressed by the AWS: - IP address; Gateway address; Subnet mask. The hospital network administrator usually supplies this information. • Provision must be made for Ethernet cables to be easily run from the Control Station to the hosiptal network. Typical equipment options which can be connected to the hosptal network include: review workstation, Mass Archiver, Laser Printer, HIS/RIS network kit, CAD (Computer Aided Detection). 13. TELEPHONE CONNECTION It is recommended that a telephone is provided close to the X-ray Console (normally mounted on the Control Station), to allow convenient dialog with teleservice technicians. 14. ASSOCIATED REVIEW WORKSTATIONS Planning information for the Seno Advantage Review Workstation can be found in the Volume Share/ AW/SA Pre-Installation Manual, 5180573-x-100. Page no. 359 Chap-Pre-Requirements.fm Chapter 4 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Pre-Installation System Requirements This page is blank. Chapter 4 Page no. 360 Chap-Pre-Requirements.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Pre-Installation Procedures CHAPTER 5 PRE-INSTALLATION PROCEDURES The following pages list recommended procedures for planning and implementing the installation of a Senographe system. Page no. 361 Chap-Pre-Procedures.fm Chapter 5 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Pre-Installation Procedures This page is blank. Chapter 5 Page no. 362 Chap-Pre-Procedures.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Scenario PRE A001 - Pre-installation Procedures Scenario PRE A001 - Pre-installation Procedures 1 Chapter 5 CONTEXT This scenario provides a check list for use in planning and carrying out pre-installation work. 2 STEERING GUIDE # Requirement Reference Who? Scenario PRE A002 - Prepurchase Site Visit GEMS sales representative Done? Pre-purchase site visit 1 Visit the proposed site to check for any potential problems associated with installation. Purchase Senographe system 2 GEMS sales representative Order Senographe system with all appropriate options from the Price Book. For customers in all countries except China, order the optional line supply cable. For customers in China, order an equivalent CCC-certified line supply cable from the Price Book. For more information see Line Supply Cable on page 337. 3 If the floor thickness is less than 120 mm and/or the installation is in a seismic area, order different anchoring bolts to those that are supplied with the system. Anchoring Inserts on page 354 Installation planning visit 4 Visit site to assess installation requirements and specify the preparatory work required before delivery and installation. Scenario PRE A003 Installation Planning Visit GEMS site planner Preparatory work 5 Hospital or third-party contractors carry out preparatory work. Hospital Pre-delivery check 6 Visit site to confirm that the preparatory work is satisfactory and the site is ready for delivery and installation. Scenario PRE A004 - PreDelivery Check GEMS site planner Delivery and storage 7 System delivery to designated storage. Chapter 4 Pre-Installation Delivery personnel and hospital System Requirements, section 9 Planning for Storage Installation 8 System installation. GEMS installation engineers Page no. 363 SC-PRE-A001.fm Chapter 5 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Scenario PRE A001 - Pre-installation Procedures This page is blank. Chapter 5 Page no. 364 SC-PRE-A001.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Scenario PRE A002 - Pre-purchase Site Visit Scenario PRE A002 - Pre-purchase Site Visit 1 Chapter 5 CONTEXT This scenario provides a check list for use in planning and carrying out a pre-purchase site visit. 2 STEERING GUIDE # Requirement Reference Who? Done? Altitude 1 Check that product specifications are compatible with the altitude of the site Chapter 4 Pre-Installation System Requirements, section 1 Environmental Requirements Hospital engineer Chapter 4 Pre-Installation System Requirements, section 1 Environmental Requirements Heating engineer Chapter 4 Pre-Installation System Requirements Site planner Chapter 4 Pre-Installation System Requirements, section 5 Electrical Requirements Hospital engineer Chapter 4 Pre-Installation System Requirements, section 12 Networking Connections Hospital engineer, GEMSE HMS representative Chapter 4 Pre-Installation System Requirements, section 11 Insite Connection Hospital engineer Operating conditions 2 Check that operating the temperature and humidity requirements can be met Rom layout 3 Check that an adequate room is available, with suitable floor and access Electrical supply 4 Check availability of suitable supply Networking 5 Check possibility of connection to hospital network Insite connection 6 Check availability and type of broadband connection Page no. 365 SC-PRE-A002.fm Chapter 5 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Scenario PRE A002 - Pre-purchase Site Visit This page is blank. Chapter 5 Page no. 366 SC-PRE-A002.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Scenario PRE A003 - Installation Planning Visit Scenario PRE A003 - Installation Planning Visit 1 Chapter 5 CONTEXT This scenario provides a check list for use in planning and carrying out an installation planning visit. 2 STEERING GUIDE # Action Reference Who? Done? Storage conditions 1 Check the dimensions and environment of the pre-installation storage room. Chapter 4 Pre-Installation System Requirements, section 9 Planning for Storage Hospital engineer Room layout 2 Plan and specify layout with adequate spac- Chapter 4 Pre-Installation System ing between the Gantry and control station Requirements, section 10 Room components. Layout Planning Site planner Operating conditions 3 Check that operating the temperature and humidity requirements will be met Chapter 4 Pre-Installation System Requirements, section 1 Environmental Requirements Heating engineer Radiation protection (wall, ceiling, floor, doors) 4 Consult the Radiation Physicist for advice on radiation protection. Chapter 4 Pre-Installation System Requirements, section 8 Planning for Radiation Protection Radiation protection specialist Structural requirements 5 Check access door width and height. Chapter 4 Pre-Installation System Requirements, section 4 Structural Requirements Hospital engineer 6 Check floor requirements (strength, flatness). Chapter 4 Pre-Installation System Requirements, section 4 Structural Requirements Flooring specialist Room Layout Planing 7 Make the underfloor plan localizing the water and electrical ducts Hospital engineer 8 Plan the location of the main components. Chapter 4 Pre-Installation System Requirements, section 10-3 Anchoring to the Floor Hospital engineer + GEMS Site planner 9 Specify the installation of anchorage bolts. In seismic areas, anchors must be provided for the generator cabinet and ancillary equipment (additional radiation screen, etc.). Chapter 4 Pre-Installation System Requirements, section 10-3 Anchoring to the Floor Flooring specialist 10 Plan cable runs; specify ducting, etc. Chapter 4 Pre-Installation System Site planner Requirements, section 10-4 Interconnecting Cables Path and Length Page no. 367 SC-PRE-A003.fm Chapter 5 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Scenario PRE A003 - Installation Planning Visit # Action Reference Who? Done? Electrical requirements 11 Check that room power supply requirements will be met. Chapter 4 Pre-Installation System Requirements, section 5 Electrical Requirements Electrician 12 Check the line voltage specification. Chapter 4 Pre-Installation System Requirements, section 5 Electrical Requirements Electrician 13 Check the line frequency specification. Chapter 4 Pre-Installation System Requirements, section 5 Electrical Requirements Electrician 14 Check the kVA load characteristics. Chapter 4 Pre-Installation System Requirements, section 5 Electrical Requirements Electrician 15 Check the line impedance. Chapter 4 Pre-Installation System Requirements, section 5 Electrical Requirements Electrician 16 Check the main circuit breaker characteristics. Chapter 4 Pre-Installation System Requirements, section 5 Electrical Requirements Electrician Chapter 4 Pre-Installation System Requirements, section 5 Electrical Requirements Electrician Chapter 4 Pre-Installation System Requirements, section 11 Insite Connection Hospital Network Administrator Door protection switches 17 Specify the requirement for provision and connection of the door X-ray protection switches. Insite connection 18 Specify requirements for Insite broadband connection Networking 19 Specify network connections and cable runs. Chapter 4 Pre-Installation System Requirements, section 12 Networking Connections Site planner 20 Allocate IP, Gateway, and Subnet mask addresses. Chapter 4 Pre-Installation System Requirements, section 12 Networking Connections Hospital Network Administrator Chapter 4 Pre-Installation System Requirements, section 7 Room Lighting Lighting specialist Lighting 21 Specify requirements for dimmer switches, drapes, etc. Chapter 5 Page no. 368 SC-PRE-A003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Scenario PRE A004 - Pre-Delivery Check Scenario PRE A004 - Pre-Delivery Check 1 Chapter 5 CONTEXT This scenario provides a check list for use in planning and carrying out a pre-delivery check visit. 2 STEERING GUIDE # Requirement Reference Who? Done? Storage conditions 1 Check preparation of pre-installation storage room Chapter 4 Pre-Installation System Requirements, section 9 Planning for Storage Hospital engineer Chapter 4 Pre-Installation System Requirements, section 10 Room Layout Planning Site planner Room preparation 2 Check the proposed layout and preparations for cable runs. 3 Check floor and anchorage preparation. Chapter 4 Pre-Installation System Requirements, section 10 Room Layout Planning Flooring specialist 4 Check access requirements. Hospital engineer Chapter 4 Pre-Installation System Requirements, section 4 Structural Requirements Radiation protection (wall, ceiling, floor, doors) 5 Check preparation for radiation protection (wall, ceiling, doors); Chapter 4 Pre-Installation System Requirements, section 8 Planning for Radiation Protection Radiation protection specialist Chapter 4 Pre-Installation System Requirements, section 11 Insite Connection Hospital Network Administrator Chapter 4 Pre-Installation System Requirements, section 7 Room Lighting Lighting specialist Insite connection 6 Check preparations for Insite broadband connection Lighting 7 Check room lighting conditions Page no. 369 SC-PRE-A004.fm Chapter 5 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Scenario PRE A004 - Pre-Delivery Check This page is blank. Chapter 5 Page no. 370 SC-PRE-A004.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PRE A001 - Checking for Damage Job Card PRE A001 - Checking for Damage Chapter 5 The Senographe DS system is inspected for proper operation and appearance before shipment. However, it is necessary to inspect the product after the shipment is received. The Senographe DS system is supplied in three different pallets as follows. Pallets Contents 1 Gantry Generator Cabinet 2 Control Station 3 Image Receptor (Digital Detector) 4 Accessories Cabinet, containing: Monitor Bucky Accessories Box (containing X-ray Console) Installation Kit Mag Stand 1.5 Mag Stand 1.8 Coolant Kit Pallets for overseas shipment are protected by a wood and cardboard cover with shock and tilt indicators. Pallets for road shipment do not have this cover. 1 POSSIBLE TYPES OF DAMAGE Two types of possible damage can exist, as follows: • External (noted) damage:damage is visible on the packages and there may or may not be actual damage to the contents of the packages. This type of damage is a consequence of bad transportation. • Internal (concealed) damage: no damage is visible on the packages however there is actual damage to the contents of the packages. This type of damage is a consequence of bad manufacturing. The illustration on the below summarizes the general process to determine: • whether any of the Senographe components are damaged • the cause (and liability) of possible damage • whether you have to make a claim for damage with the carrier company • whether you have to make a manufacturing claim for damage or components considered dead on arrival (DOA) with GE Healthcare Page no. 371 JC-PRE-A001.fm Chapter 5 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PRE A001 - Checking for Damage Phase 1: Pre-installation/delivery time Externally inspect packages (Checking for External Damage on page 373) External visible damage ? Yes No Conduct delivery inspection with carrier (Delivery Inspection with Courier on page 373) Conduct post delivery inspection with carrier (Conduct post-delivery Inspections on page 373) Report damage and make a transportation claim (Reporting Damage on page 374) Phase 2a: Physical installation Internally inspect package contents (Checking for Internal Damage on page 373) Internal visible damage ? Yes No Physical DOA? Phase 2b: Electrical installation Yes No Electrical DOA? Report damage and make a manufacturing claim (Reporting Damage on page 374) Yes No No damage to report and therefore no claim required The damage checking process is split into two main phases. • The first phase must be undertaken during the delivery complaint period defined by your country consumer laws (usually 14 days). So that in the event that external damage has occurred, the liability of the damage can be attributed to the carrier company. ! Notice: External (noted) damage must be reported to the carrier immediately upon discovery, or in any event within the delivery complaint period (defined by your local consumer laws) after receiving the delivery (e.g.14 days in the USA). A transportation company will not pay a claim for damage if a post-delivery inspection is not requested within the delivery complaint period defined by your country consumer laws (usually 14 days). • The second phase can be undertaken later during physical and electrical installation of the Senographe system. Any damage found during this phase is considered as either physical DOA or electrical DOA, which is the responsibility of GE Healthcare manufacturing. Chapter 5 Page no. 372 JC-PRE-A001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PRE A001 - Checking for Damage 2 CHECKING FOR EXTERNAL DAMAGE 2-1 Delivery Inspection with Courier When the shipment of the Senographe system arrives, a General Electric representative or a hospital receiving agent must proceed as follows for each of the three pallets. 1. Closely examine each pallet for visible damage, and check any shock and tilt indicators present. If the pallets in the shipment show visible signs of damage, excessive shock, etc. you must perform a delivery inspection as follows: a. Open the pallets immediately to check the contents, and ask the driver to inspect the contents with you. b. Write a precise description of the damage on your copy and carriers copy of the delivery receipt, along with the notation "damage in shipment". c. Sign for the shipment and arrange a post-delivery inspection within delivery complaint period defined by your country consumer laws. d. Contact GE Healthcare to report the initial damage according to section 4, Reporting Damage. If the pallets in the shipment do not show visible signs of damage or excessive shock, no action is required other than to sign for the shipment. 2. Move the pallet into or close to the x-ray room, ready for unpacking. 2-2 Conduct post-delivery Inspections Contact the Customer Service Department at phone number provided on the carriers bill to help you determine whether a post-delivery inspection and formal written report is required. Occasionally, the carrier may not have an inspector examine the damaged freight. Instead, they may request that you do the post-delivery inspection yourself and keep a written description. This written description can be used if a transportation claim is filed later. Note, that a post-delivery inspection report is not a transportation claim. Once you have completed a post-delivery the details of the damage to GE Healthcare and the carrier according to section 4, Reporting Damage. 3 CHECKING FOR INTERNAL DAMAGE As soon as possible after delivery, unpack, and inspect your shipment. If you discover internal (concealed) damage, report it to GE Healthcare immediately according to section 4, Reporting Damage. Page no. 373 JC-PRE-A001.fm Chapter 5 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PRE A001 - Checking for Damage 4 REPORTING DAMAGE 1. Contact the GE Healthcare Distributor and/or GE Healthcare Account Manager from which the product was purchased to inform them of the damage. Be ready to supply the following information: • name of carrier • delivery date • consignee name • freight or express bill number • item damaged • extent of damage 2. The GE Healthcare Distributor and/or GE Healthcare Account Manager will contact the factory of origin to determine the most cost effective way to repair the damage. • If damage deemed to warrant a factory repair, a Return Merchandise Authorization (RMA) will be issued to return damaged product to factory. Factory will provide quote to repair damaged equipment after inspection of damage upon receipt of damaged equipment. Do not ship any damaged product back to factory without an RMA. • If damage is deemed minimal and can be repaired in the field with replacement parts, the factory will provide a quote to the consignee to purchase those parts. • If damage is deemed catastrophic and requires complete replacement of damaged equipment, GE Healthcare will provide a quote to the consignee with quote to replace damaged equipment. 3. Discuss how to proceed with your GE Healthcare Distributor and/or GE Healthcare Account Manager: • If you determined that the bad transportation was to blame for the damage then your GE Healthcare Distributor and/or GE Healthcare Account Manager will advise you how to file a transportation claim and how to proceed with the transportation claim process. • If you determined that the transportation was not to blame for the damage then your GE Healthcare Distributor and/or GE Healthcare Account Manager will advise you how to file a manufacturing claim and how to proceed with the manufacturing claim process. Chapter 5 Page no. 374 JC-PRE-A001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Physical Installation CHAPTER 6 PHYSICAL INSTALLATION This chapter contains information for the physical installation of the Senographe system. Page no. 375 Chap-Physical Install.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Physical Installation This page is blank. Chapter 6 Page no. 376 Chap-Physical Install.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card LOTO A001 - Lock-Out / Tag-Out (LOTO) Procedures Job Card LOTO A001 - Lock-Out / Tag-Out (LOTO) Procedures 1 INTRODUCTION Lock-out / Tag-out (LOTO) is a process that ensures all energy sources are locked in a safe condition, and remain secured in order to prevent the unintentional energizing of equipment. This Job Card establishes the minimum requirements according to European Law on Occupational Health and Safety and the GEHC Standards, for locking out live power in order to achieve the power isolation required to carry out any installation, de-installation, maintenance, or repair work on the Senographe system. All authorized personnel are required to follow these instructions, as well as any other safety procedures related to the operation of the Senographe system, or to work carried out in areas close to the Senographe system. WARNING Failure to isolate dangerous power sources may cause serious injury or death. 2 SUPPLIES LOTO KIT B A C D E G F H Page no. 377 JC-LOTO-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card LOTO A001 - Lock-Out / Tag-Out (LOTO) Procedures LOTO kit, which comprises: • Small Yellow Box (A) — used to secure disconnected power cable connections. • Large Yellow Box (B) — used to secure disconnected power cable connections. • Red Padlock (and key) (C) and Red Label (D) — a personal padlock owned by a indvidual Field Engineer which is used during work time. • Yellow Padlock (and key) (E) and Yellow Label (F) — used during non-work time (i.e. overnight/shift change or over weekends). • Mutihasp (G) — use in conjucntion with multiple padlocks when more than one Field Engineer is required for the task. Note: Multihasps vary in shape and size depending on the design of the Mains Distribution Panel. Their principle of use is the same in that they allow more than on Field Engineer to secure the system with their personal red padlock. • Blue "Lockout Point" Labels (H). 3 • • 4 TOOLS Standard Tool Box Digital Multimeter with a 1000V rating REQUIRED EFFORT Personnel: 1 Field Engineer Time: 25 minutes 5 SAFETY PRECAUTIONS This entire Job Card is to do with safety. Follow the steps in this Job Card exactly as described. 6 POTENTIAL RISKS The following electrical risks are associtated with the Senographe system: • 220V monophase AC mains power supply in the Line Supply Cable going from the Mains Distribution Panel into the Generator • stored residual voltage within the capacitors of Generator • external power source for the room lamps that are connected to the Generator Relay board Note: The extenal power source for the room lamps must be no more than 30V. If the room lamps power source exceeds 30V you must take appropriate actions to change this source. 7 PREREQUISITES The only people authorized to perform a LOTO procedure are the Field Engineers, Support Engineers, and Field Engineering trainees who have undergone LOTO training. The person carrying out the LOTO procedure must verbally inform all personnel of the date on which the lock-out will take place and of the time at which the equipment will be operational again. Page no. 378 JC-LOTO-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card LOTO A001 - Lock-Out / Tag-Out (LOTO) Procedures 8 LOTO PROCEDURE The LOTO procedure is a series of important steps that must be followed. To perform the LOTO procedure, follow the steps descirbed in the following sub-sections. 8-1 Prepare the equipment for switch-off 1. Have the site specific LOTO procedure available to hand. This may vary from site to site and depends on the Mains Distribution Panel at the hospital. The specific LOTO procdure will be similar in content to this Job Card, but may address items that are specific to the hospital configuration. 2. Inform all the users of the Senographe system that it is currently decommissioned from operation and that they can no longer use the Senographe system until they are instructed that the Senographe system is recommissioned. 8-2 Identify the energy sources on the system 1. Identify the electical energy source on the Mains Distribution Panel which supplies AC power to the Line Supply Cable going into the Generator. 2. Identify those points where these energies exist in the system and their magnitude. For example, there may be a connection between the socket on the Mains Distribution Panel and the entrance into the Generator. 3. Identify the electical energy source which supplies electical power to the lamp cables going into the Generator Relay board. 8-3 Switch the Senographe system OFF 1. To power off the Senographe system, click the system shutdown button located towards the bottom right of the AWS Browser window. A confirmation message appears asking if the entire system should be shut down. If your response is Yes, power is removed from the Senographe Essential Gantry and other system components, while the Control Station begins a controlled shutdown, designed to safeguard data. Complete system and UPS shut down takes about two minutes from switch-off. Note: The Control Station follows an automatic shutdown procedure, which protects image and patient data. No prompts are displayed. Do not disturb this procedure by attempting to enter commands at this time. 2. Ensure that the Acquisition Workstation has completed its shutdown. Shutdown is complete when there is no longer any display on the LCD Monitor screen; the screen appears black. Page no. 379 JC-LOTO-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card LOTO A001 - Lock-Out / Tag-Out (LOTO) Procedures 8-4 Isolation of the Generator Line Supply power source You must isolate two types of power source which lead into the Generator of the Senographe system: • the Mains Distribution Panel which supplies the power source for the Line Supply Cable going into the Generator • the power source for the room lamps running into the Generator 8-4-1 Isolating the Mains Distribution Panel The Mains Distribution Panel may vary in different hospital, and the specific details are listed in the site specific LOTO procedure. Use the following generic steps to isolate the power source going to the Senographe system: 1. Switch off the AC mains power going to Generator cabinet. To do this, turn the handle of the Mains Distribution Panel into the OFF position. 2. Press the OFF button on the front of the Mains Distribution Panel where fitted. 3. Turn all necessary switches/breakers on the front of the Mains Distribution Panel into the OFF position. 4. If possible, disconnect the AC mains power cable from the Mains Distribution Panel. 5. If there exists a connection between the socket on the Mains Distribution Panel and the entrance into Page no. 380 JC-LOTO-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card LOTO A001 - Lock-Out / Tag-Out (LOTO) Procedures the Generator, then disconnect this connection and secure it with a yellow box. 8-4-2 Isolating the Room Lamps power source You must locate and isolate the power source of the room lamps that route electrical enegry into the Relay Board on the Generator. The room lamps power source can vary in different hospitals, but typically you will need to cut the power source circuit breaker or isolator. Page no. 381 JC-LOTO-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card LOTO A001 - Lock-Out / Tag-Out (LOTO) Procedures 8-5 Apply LOTO You must apply LOTO to the power source of the Line Supply Cable (i.e. the Mains Distribution Panel). 1. If the activity requires one Field Engineer, install the red LOTO padlock onto the Mains Distribution Panel, as follows: • On the Mains Distribution Panel insert the red LOTO padlock and red LOTO label to isolate incoming supply. • If there exists a connection between the socket on the Mains Distribution Panel and the entrance into the Generator, then secure the yellow box with an additional red LOTO padlock and red LOTO label. • The key and the red LOTO padlock is the personal property of the individual Feild Engineer and must never be loaned to others. If the activity requires more than one Field Engineer install the Multihasp onto the Mains Distribution Panel: • If required, use the appropriate RED plastic adapter from the LOTO kit to lock-out individual breakers according to size or type. • Use a multihasp in conjunction with a red LOTO padlock and LOTO red tag for each Field EngiPage no. 382 JC-LOTO-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card LOTO A001 - Lock-Out / Tag-Out (LOTO) Procedures neer. • If there exists a connection between the socket on the Mains Distribution Panel and the entrance into the Generator, then secure the yellow box with a multihasp in conjunction with a red LOTO padlock and LOTO red tag for each Field Engineer. 2. Write the date and Field Engineer name on each of the red labels. 3. Apply reasonable (not excessive) force to perform a "TRY-OUT". Make sure that the LOTO device does not allow you to switch on the power at the Mains Distribution Panel . Page no. 383 JC-LOTO-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card LOTO A001 - Lock-Out / Tag-Out (LOTO) Procedures 8-6 Discharge any stored energy 1. Remove the four Generator side panels (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513). 2. Use a Digital Multimeter to ensure that the Line Supply Cable voltage between L1 and N is at 0 Volts. L1 N 3. Wait at least five minutes to discharge the stored electric energy in the capacitors. 4. Check residual voltage using a Digital Mulitmeter (do not rely on Neon "Tell Tales"). Check for zero volts on both fuses 5. Use a voltmeter with a rating of 1000 V DC to check that there is no residual voltage between screws S1 and S2 on the Generator. RC1 RC2 S1 S2 Page no. 384 JC-LOTO-A-001.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card LOTO A001 - Lock-Out / Tag-Out (LOTO) Procedures 6. Use to Digital Multimeter to check that the 27 V circuit is at 0 V between the following items of the Supply Command Board 200PL2: • Test Points P27V and 0/27V. • Connections on each side of Fuse F3. XJ3 F1 XJ4 F3 TP1 XJ9 F2 XJ8 TP2 TP3 0VV TP4 TP9 F6 TP5 XJ3 XJ1 Fuse F3 TP6 TP7 TP8 TP10 TP12 XJ10 TP13 XJ6 TP15 P250V P27V 27 V Test Points XJ7 0V/27V XJ2 TP16 TP19 TP18 0V/250V TP19 F5 XJ5 TP21 F4 TP19 Page no. 385 JC-LOTO-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card LOTO A001 - Lock-Out / Tag-Out (LOTO) Procedures 8-7 Verify lamp electrical source is within safe limits The cables between the XJ1, XJ2 and XJ3 connectors on the Generator Relay board contain a live voltage of up to 30V from an external source. This voltage is not harmful to people working on the Generator, however the source must be isolated and off when you undertake maintanance or corrective work so that there is no risk of causing a short circuit which can damage the Generator or the external power supplies. For personnel safety, it is extremely important that you ensure that this voltage is no more than the values specified in the following steps. 1. Temporarily switch on the room lamp power source in the hospital. ! ! Upto 30V only permitted on XJ1 and XJ2 connectors Upto 24Vdc only permitted on XJ3 connector 2. Use a Digital Multimeter to ensure that the X-ray ON and Seno ON lamp cables voltage between the XJ1 and XJ2 connectors on the Generator Relay board are at 30 V or less. • If the voltage is above 30 V (AC or DC) then before you proceed with your planned maintenance or corrective tasks you must ensure that the electical energy source which supplies power to the X-ray ON and Seno ON lamp cables is changed so that no more than 30V (AC or DC) is supplied to the Generator Relay board. • If the voltage is 30 V (AC or DC) or less then proceed with your planned maintenance or corrective tasks. 3. Close the room door to ensure that a voltage is present on the Relay board XJ3 connector. Use a Digital Multimeter to ensure that the room door cables voltage between the XJ3 connector on the Generator Relay board are at 24 Vdc or less. • If the voltage is above 24 Vdc then before you proceed with your planned maintenance or corrective tasks you must ensure that you must ensure that the electical energy source which supplies power to the room lamp cables is changed so that no more than 24Vdc is supplied to the Generator Relay board. • If the voltage is 24 Vdc or less then proceed with your planned maintenance or corrective tasks. 4. Isolate the power source of the room lamps that route electrical enegry into the Relay Board on the Generator. The room lamps power source can vary in different hospitals, but typically you will need to cut the power source circuit breaker or isolator. Page no. 386 JC-LOTO-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card LOTO A001 - Lock-Out / Tag-Out (LOTO) Procedures 9 PROCEDURE FOR THE RECONNECTION OF THE EQUIPMENT Follow this procedure to return the Senographe system or subsystem components to its normal operation 1. Inform everybody of the reconnection of the device. 2. Check the area and the equipment. 3. Make sure that all the parts and covers are correctly fitted. 4. Remove the tools from the area of the system. 5. Remove the LOTO devices including locking pins or bolts. 6. Re-establish the power to the system. 7. Return the equipment in its normal operating state. 8. Perform a system function check. Page no. 387 JC-LOTO-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card LOTO A001 - Lock-Out / Tag-Out (LOTO) Procedures This page is blank. Page no. 388 JC-LOTO-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Scenario PHY A001 - Physical Installation Scenario PHY A001 - Physical Installation 1 Chapter 6 CONTEXT This Scenario provides information for the physical phase of a first installation of Senographe equipment on the customer site. The installation is split into two phases: • Physical installation: positioning and cabling the various sub-systems without applying power. This is treated in this scenario. • Electrical installation: powering on the system, configuration, and verification, up to start-up with the customer. Refer to chapter 7 Electrical Installation on page 535. 2 STEERING GUIDE Refer to the following Steering Guide for an outline of the recommended sequence of physical installation. Physical Installation Steering Guide - Preparation, Physical Installation, and Connection. Step Job Card Comments Done Preparation 1 Schedule appointments: Delivery date, movers, etc. None 2 Check room preparation (See PIM inspection report and the structural engineer site survey report) None Physical Installation 3 Unpack Generator and Gantry pallet Move Generator + Gantry to X-ray room Job Card PHY A001 - Unpacking the Gantry and Generator Cabinet on page 391 4 If the hospital doors are too low for the height of the Gantry with its covers on, remove the Gantry Covers Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. 5 If the hospital site does not allow you to transport the Generator and Gantry together, disconnect them and move them individually into the X-ray room Generator Disconnection Procedure on page 483 in Job Card PHY A030 Generator and Gantry Disconnection Reconnection 6 Unpack Control Station Move Control Station to X-ray room Job Card PHY A002 - Unpacking the Control Station on page 397 7 Establish the optimum positions for Gantry, Generator, and Control Station and decide whether the LCD Monitor must be mounted on the other side. Obtain the customer agreement. Anchor the Gantry and the Control Station Two persons required Job Card PHY A003 - Gantry and Control Station Installation on page 401 Page no. 389 SC-PHY-A-001.fm Two persons required Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Scenario PHY A001 - Physical Installation Step Job Card Comments Done Connections 8 Remove Control Station front cover Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503 9 Connect Gantry to Control Station Connect Control Station to network Job Card PHY A014 - Connect Gantry to Control Station on page 455 10 Clean IDC filter 11 If you did not have to separate the Generator and Gantry (see 4) remove the Generator covers to access the Generator Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513 12 If you had to separate the Generator and Gantry (see 4) then reconnect them together Generator Reconnection Procedure on page 492 in Job Card PHY A030 Generator and Gantry Disconnection Reconnection 13 Connect HT cable Job Card PHY A015 - HT Cable Connection on page 467 14 Connect AC supply to Generator Job Card PHY A016 - AC Connection on page 469 15 X-ray Console Cable Routing and connect X-ray Console to Generator Job Card PHY A012 - X-ray Console Cable Routing on page 451 16 Connect the Door safety switches and the X-ray lamp to Generator Job Card PHY A018 - Room Lamps and Door Configuration on page 475 Job Card PM A425 - IDC Air Filter Cleaning on page 1803 Completion 17 Optionally change mouse for trackball Job Card PHY A011 - Trackball Option Installation on page 443 Optional 18 Unpack/Install Radiation Screen Job Card PHY A004 - Radiation Screen Installation on page 405 Two persons required 19 Opposite Side Rotative Arm Installation Job Card PHY A009 - Opposite Side Rotative Arm Installation on page 415 Optional 20 Mount LCD monitor on Control Station Job Card PHY A010 - Mount LCD Monitor on Control Station on page 435 21 Install Bucky Support Job Card PHY A005 - Bucky Support Installation on page 409 22 Apply the regulatory and safety label as required Job Card PHY A006 - Regulatory and Safety Labelling on page 411 Chapter 6 Page no. 390 SC-PHY-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A001 - Unpacking the Gantry and Generator Cabinet Job Card PHY A001 - Unpacking the Gantry and Generator CabinetChapter 6 1 SUPPLIES None 2 • • TOOLS Standard Tool Box Claw hammer or other suitable tool for removing packing nails 3 REQUIRED EFFORT Personnel: 2 Field Engineers Time: 60 minutes 4 SAFETY PRECAUTIONS WARNING - Two persons are needed for unpacking and moving the Gantry and Generator; Follow standard safety practices for handling heavy equipment. - When using a fork-lift to move the loaded pallet, always insert it on the Generator Cabinet side; the other is blocked. - Never move the Gantry by pushing on the covers. - Do not remove the securing straps from the Generator Cabinet until it is ready to be removed from the pallet - When moving the Gantry, so it cannot tip over, never apply excessive force at the top of the Gantry. 5 PREREQUISITES None 6 UNPACKING THE EQUIPMENT General Electric Medical Systems recommend that you always put the palette on flat, level ground before you begin to unpack the Gantry and Generator Cabinet. The objective is to unpack the Gantry, Generator, and accessories and move them to the mammography room. Do not remove the packing on the Image Receptor. WARNING The Image Receptor is delicate, and can be easily damaged if subjected to any shock. Do not remove the packing on the Image Receptor at this stage. It will be removed after all movement and installation work has been completed. 6-1 Reception The Gantry and Generator Cabinet are delivered on a single pallet. The Control Station is delivered on another pallet. The radiation screen, digital detector, monitor and the accessories are delivered on another pallet. When a Senographe system arrives, check the entire consignment for damage according to Job Card PRE A001 - Checking for Damage on page 371. Page no. 391 JC-PHY-A-001.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A001 - Unpacking the Gantry and Generator Cabinet 6-2 Unpack the Generator Cabinet 1. Remove the securing straps from the generator cabinet. B A 2. For each of the two red clamping brackets securing the cabinet to the pallet: a. Remove the two bolts which hold the bracket to the pallet. b. Remove the protective film from the strips of adhesive tape on the bracket and on the bottom edge of the cover panel immediately above the panel. c. Push the bracket firmly upwards as shown (C) so that it is held up by the adhesive tape. C 3. Remove the screws (B) which hold the two wooden blocks underneath the cabinet; remove the blocks. 4. Leave the two brackets in place (held to the covers by the adhesive tape) until you are ready to remove the covers and connect the system. Then remove them and place them with the other packing materials for return. 5. Unpack the Gantry and remove the Gantry from the pallet (see Unpack Gantry on page 393). 6. Carefully roll the cabinet (and the Gantry together) down the ramp and into the mammography room. CAUTION Take care that the generator cabinet does not catch and jump while moving down the ramp. The center of gravity of the generator cabinet and the Gantry cabinet are high. Chapter 6 Page no. 392 JC-PHY-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A001 - Unpacking the Gantry and Generator Cabinet 6-3 Unpack Gantry 1. The Gantry base sits on four wooden blocks (1) so that the Gatry base wheels are raised from the pallet floor. Three bolts (one at the front and two at the back) (2) are attached from the Gantry base to a metal plates which exist below the pallet floor. 1 2. Ensure that the three bolts are perpendicular to the Gantry base so that you do not damage the bolt threads. Gantry base Gantry base Gantry base BAD : Not perpendicular Risk of thread damage GOOD : Perpendicular No risk of thread damage Page no. 393 JC-PHY-A-001.fm Gantry base Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A001 - Unpacking the Gantry and Generator Cabinet 3. Carefully unscrew (turn anti-clockwise) each of the three bolts (2) that secure the Gantry base to the pallet (ratchet wrench with a 22 mm socket). Pay special attention not to damage the thread on each of the bolts as they are used later to raise the Gantry. 2 3 4. Remove the metal bars (3) from below the pallet floor. Keep these metal bars as they are used to raise the Gantry. 5. Continue to unscrew carefully each of the three bolts so that the end of each bolt (4) appears above the pallet floor. To release these bolts, remove the nut (5) attached to each of the bolts. Ensure that you leave enough space so you can remove each nut (5), and so you can place the metal bar below the screw and the surface of the pallet floor. 5 4 Chapter 6 Page no. 394 JC-PHY-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A001 - Unpacking the Gantry and Generator Cabinet 6. For each of the three bolts, place the metal bar (6) you removed earlier below the screw. Ensure that the metal bar fully covers the hole in the pallet floor. 6 7. Carefully re-screw (turn clockwise) each of the bolts so that they make contact with the metal bar. 8. Continue to re-screw carefully (turn clockwise) each of the bolts so that they raise the Gantry off of the wooden blocks as shown below. Ensure that you raise the Gantry progressively (keep the base close to horizontal). 9. When the Gantry base is high enough to be clear of the two wooden support blocks, remove these blocks. 10. Lower the Gantry progressively (keep the base close to horizontal). Do this by unscrewing (turning anti-clockwise) each of the three bolts until the Gantry is fully supported by the wheels. 11. Ensure that the Gantry cannot roll on the wheels. Continue to unscrew (turn anti-clockwise) each of Page no. 395 JC-PHY-A-001.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A001 - Unpacking the Gantry and Generator Cabinet the three bolts so that they are approximately 1 cm above the pallet floor. Leave the bolts threaded into the Gantry base. Install the long wooden ramp (7), coming from column packaging, to the side of the Gantry (right or left). 7 12. Carefully roll the Gantry (along with the Generator cabinet) down the ramp and into the mammography room. CAUTION Never push the Gantry covers to move the Gantry on its wheels. Push the base, or if necessary pull on the large handle. 6-4 Accessories The box of accessories is packed separately. Chapter 6 Page no. 396 JC-PHY-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A002 - Unpacking the Control Station Job Card PHY A002 - Unpacking the Control Station 1 Chapter 6 SUPPLIES None 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 2 Field Engineers Time: 60 minutes 4 SAFETY PRECAUTIONS WARNING The Control Station weighs 115 kg. Two persons are needed for unpacking and moving the Control Station. Follow standard safety practices for handling heavy equipment. Before moving the Control Station on its transportation wheels, ensure that the wheels are oriented in the desired direction of movement. If not, the Control Station can tip over. When moving the Control Station, so it cannot tip over never apply excessive force at the top of the Control Station. 5 PREREQUISITES None 6 PROCEDURE 6-1 Reception The Control Station is delivered on a single pallet. The Gantry and Generator Cabinet are delivered on another pallet. The radiation screen, digital detector, monitor and the accessories are delivered on pallets. When a Senographe system arrives, check the entire consignment for damage according to Job Card PRE A001 - Checking for Damage on page 371. Note: The Accessories box (located in the large wooden Accessories cabinet) that is delivered with the Senographe system contains many useful items. This box includes ADS/IDC Software, Looback Kit, Service Documents, and Left Stop Bracket Set etc. You must never throw away any of the items in the Accessories box as they can be required at a later date. Page no. 397 JC-PHY-A-002.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A002 - Unpacking the Control Station 6-2 Removal from Pallet 1. Unpack the equipment. 2. Install the long wooden ramp (1), coming from column packaging, to the right hand side of the Control Station (the side that is connected to the Gantry). 1 3. On the left hand side of the Control Station, remove the three hex bolts (2) that secure the bracket to the Control Station base. 2 Chapter 6 Page no. 398 JC-PHY-A-002.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A002 - Unpacking the Control Station 4. On the right hand side of the Control Station: • remove the three hex bolts (3) that secure the bracket to the Control Station base • remove the two hex bolts (4) that secure the bracket to the pallet • remove the bracket from between the Control Station base and pallet • remove the bolt (5) that secures the rectangular bracket to the pallet, and remove the rectangular bracket 3 4 4 5 5. With the ramp in place, guide the Control Station off of the pallet. 6-3 Unpacking 1. Unpack the accessories pallet box containing the monitor, the radiation screen, and the accessories. 2. Examine all items for damage. If there are any signs of damage, refer to Job Card PRE A001 Checking for Damage on page 371. If there are no signs of damage, set them aside until required for connection. 3. Collect all packing material for disposal. Page no. 399 JC-PHY-A-002.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A002 - Unpacking the Control Station This page is blank. Chapter 6 Page no. 400 JC-PHY-A-002.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A003 - Gantry and Control Station Installation Job Card PHY A003 - Gantry and Control Station Installation 1 Chapter 6 SUPPLIES Anchoring kits: • For Gantry: • • • • • 1 5 securing screws (1). 5 anchoring inserts (2). 3 leveling screws(3). 3 jack feet (4). 6 caps for holes (5). 3 4 5 2 • 2 • • 3 For Control Station • 4 securing screws. • 4 anchoring inserts. • 4 jack feet. TOOLS Standard Tool Box Drill and drill bits (drill bit sizes and hole depths vary according to the bolts used - see Anchoring Inserts Provided with the Senographe System (only for non-seismic areas) on page 354 and Anchoring Inserts Not Provided with the Senographe System (for seismic areas) on page 355)). REQUIRED EFFORT Personnel: 1 Field Engineer Time: 60 minutes 4 SAFETY PRECAUTIONS CAUTION Follow standard safety practices for handling heavy equipment. Never push on the covers to move the Gantry on its wheels. Push the base, or if necessary pull on the large handle. Before moving the Control Station on its transportation wheels, ensure that the wheels are oriented in the desired direction of movement. If not, the Control Station can tip over. Page no. 401 JC-PHY-A-003.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A003 - Gantry and Control Station Installation 5 PREREQUISITES • • • 6 The procedures described in Job Card PHY A001 - Unpacking the Gantry and Generator Cabinet on page 391 must have been completed. The floor positions for the bolts securing the Gantry and the Control Station must have been agreed and marked as described in Anchoring to the Floor on page 354). When establishing the position for the Generator Cabinet, note that the "CE" marking label, located on one of the large side panels of the Generator, must remain visible after installation. PREPARE THE ANCHOR POSITIONS FOR GANTRY AND CONTROL STATION ! Notice: For safety reasons, it is mandatory that the Gantry and the Control Station are securely bolted to the floor. 1. Before proceeding, it is recommended that you perform a final verification of the information given in the Pre-Installation Manual. Particularly, verify clearances around the Gantry and Control Station when installed in its permanent position. 2. Ensure that suitable provision has been made for passage of cable harnesses between the Gantry, the Generator, and the Control Station. Connections are already made in the Gantry and Generator. The Control Station cable harness (set of cables in a black flexible conduit) must be routed and connected after it has been installed. A cable must be run from the Generator to connect the X-ray Console. If the X-ray Console is positioned on the Control Station, the cable can be run alongside the Control Station cable harness. 3. Drill and prepare the securing holes: CAUTION Check that there are no water or electrical ducts where you drill. Refer to the under-floor plan localizing the water and electrical ducts which has been done during the Pre-Installation. a. Check that the seven mounting hole centers have been correctly marked. b. Drill the mounting holes, three (five in seismic areas) for the Gantry and four for the Control Station. Drill-bit sizes and hole depths vary according to the bolts used - see Anchoring Inserts Provided with the Senographe System (only for non-seismic areas) on page 354 and Anchoring Inserts Not Provided with the Senographe System (for seismic areas) on page 355)). c. Place an insert into each of the mounting holes, ready to receive one of the bolts provided. Chapter 6 Page no. 402 JC-PHY-A-003.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A003 - Gantry and Control Station Installation 7 INSTALL AND ANCHOR THE GANTRY Note: Do not remove the packing from the Image Receptor until all operations that can cause dust and disturbance in the area have been completed. 1. Wheel the Gantry to its correct position, with the three baseplate mounting holes aligned with the three holes drilled in the floor. 2. Place the three flat round jack feet (1) on the floor with their nipples facing upwards. 3. Turn the three jacking bolts downwards until their hollowed ends engage with the nipples of the jack feet. 2 4. Use the ratchet wrench with a 22 mm socket to jack up progressively the Gantry. Do this turning the three jacking bolts (2), until the wheeled bars are clear of the floor. 1 5. Use the 8 mm allen wrench to remove the screws (3) securing the wheeled bars (4). Remove the bars. 6. Turn the jacking bolts to lower the Gantry, ensuring that the baseplate remains as horizontal as possible, until it is fully supported by its baseplate. Remove the three jacking bolts completely. 3 4 Note: The three jack feet remain below the Gantry baseplate. If the floor is not perfectly even, use the three leveling screws provided in the installation kit. to level the Gantry base. Insert the min place of the jacking bolts to push on the jack feet. 7. Bolt the Gantry to the prepared inserts in the floor. Page no. 403 JC-PHY-A-003.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A003 - Gantry and Control Station Installation 8 INSTALL AND ANCHOR THE CONTROL STATION CAUTION 1. 2. 3. 4. 5. 6. Do not attempt to install the radiation shield on the Control Station cabinet before the cabinet has been secured to the floor. The radiation shield is heavy, and can make the Control Station dangerously unstable. Wheel the Control Station to its correct position aligning the baseplate mounting holes and floor anchoring points in the floor, using the three jacking bolts. Place the four flat round jack feet on the floor below the jacking bolts with their nipples facing upwards. Turn the four jacking bolts downwards until their hollowed ends engage with the nipples of the four jack feet. Jack up progressively the Control Station using the ratchet wrench with a 22 mm socket to turn the jacking bolts. Keep the base plate as close to horizontal as possible. Use the 8 mm hex wrench to remove the castor securing screws. Remove the castors. Turn the jacking bolts to lower the Control Station, ensuring that the baseplate remains as horizontal as possible, until it is fully supported by its baseplate. Remove the four jacking bolts completely. Note: The four jack feet remain below the Control Station baseplate. 7. Use the 8 mm hex wrench to remove the castor securing screws. Remove the castors. 8. Bolt the Control Station to the prepared inserts in the floor. 9. Install the Radiation Shield as described in Job Card PHY A004 - Radiation Screen Installation on page 405. Chapter 6 Page no. 404 JC-PHY-A-003.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A004 - Radiation Screen Installation Job Card PHY A004 - Radiation Screen Installation 1 Chapter 6 SUPPLIES 1. A radiation screen is provided for standard installation as part of the Control Station. 2. A separate radiation screen can be provided as an option for when clients wish to use the X-ray Console in a position away from the Control Station, or where local regulations require a larger screen. 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 2 Field Engineers Time: 30 minutes 4 SAFETY PRECAUTIONS Power to the system must be off before beginning the procedure. 5 PRE-REQUISITES The Control Station have been secured to the floor in its correct position. 6 PROCEDURE - RADIATION SCREEN ON CONTROL STATION CAUTION Do not attempt to install the Radiation Screen on the Control Station cabinet before the cabinet has been secured to the floor. Refer to Job Card PHY A003 - Gantry and Control Station Installation on page 401. The Radiation Screen is heavy, and can make the Control Station dangerously unstable. 6-1 Reception The radiation screen is delivered on a single pallet, along with the digital detector, monitor and the accessories. The Gantry and Generator Cabinet are delivered on another pallet. The Control Station is delivered on another pallet. When a Senographe system arrives, check the entire consignment for damage according to Job Card PRE A001 - Checking for Damage on page 371. Page no. 405 JC-PHY-A-004.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A004 - Radiation Screen Installation 6-2 Installation 1. According to the site configuration, remove the edge pinch (1) on the side where the radiation screen can be introduced. To do this, remove the two screws (2) and remove the edge pinch and its pinch plate. 1 2 2. Carefully put the radiation screen (3) in place. The vertical felt bands (4) must be located towards the back of the Control Station. 3 4 Chapter 6 Page no. 406 JC-PHY-A-004.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A004 - Radiation Screen Installation 3. Carefully introduce one pinch plate (5) between the edge pinch and the radiation screen. 5 6 4. Tighten with moderation the two screws (6). 5. Reinstall each edge pinch that you previously removed and secure it with two screws (7). 7 6. Carefully introduce one pinch plate (8) between the edge pinch and the radiation screen. 8 9 7. Tighten with moderation the two screws (9). Page no. 407 JC-PHY-A-004.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A004 - Radiation Screen Installation 8. Install the main frame-radshield joint (10) between the radiation screen and the frame. 10 11 9. Install the eight screw covers (11) to the fixing points of the edge pinches. Chapter 6 Page no. 408 JC-PHY-A-004.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A005 - Bucky Support Installation Job Card PHY A005 - Bucky Support Installation 1 Chapter 6 SUPPLIES Bucky Support Assembly 2 TOOLS 3 mm allen wrench 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 15 minutes 4 SAFETY PRECAUTIONS None 5 PRE-REQUISITES None 6 PROCEDURE 1. Put in place the Bucky Support (1) and secure it with two screws CHC 4 x 12 on the top (2) and two screws FHC M4 x 16 on the bottom (3) (3 mm allen wrench). 2 1 3 2. Install the four screw covers to the fixing points of the Bucky Support (8 mm diameter on the top, 14 mm diameter on the bottom). Page no. 409 JC-PHY-A-005.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A005 - Bucky Support Installation This page is blank. Chapter 6 Page no. 410 JC-PHY-A-005.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A006 - Regulatory and Safety Labelling Job Card PHY A006 - Regulatory and Safety Labelling 1 Chapter 6 SUPPLIES Safety labels for the X-ray Console (supplied with the X-ray Console). 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 5 minutes 4 SAFETY PRECAUTIONS ! Notice: The attachment of appropriate regulatory and safety labeling to the equipment is a LEGAL REQUIREMENT for operation of an X-ray producing unit. 5 PREREQUISITES None 6 • • SAFETY LABELLING ON THE X-RAY CONSOLE You must select and attach appropriate safety labels to the X-ray Console, according to local safety regulations concerning the use of X-ray producing equipment. Locate and open the safety label envelope taped underneath the X-ray Console. It contains two radiation warning labels and a surface hygiene warning label. Page no. 411 JC-PHY-A-006.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A006 - Regulatory and Safety Labelling 6-1 Radiation Warning Labels Identify the radiation warning labels illustrated below; select the one that corresponds to local regulations. ILLUSTRATION 1 - SAFETY LABELS Note: The CEI warning symbols are already screen-printed on the X-ray Console. If one of the other warning labels is required, peel off the self-adhesive backing from the selected label. Then affix it over the CEI warning symbols in the upper right corner of the X-ray Console as shown below. Affix label here Chapter 6 Page no. 412 JC-PHY-A-006.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A006 - Regulatory and Safety Labelling 6-2 Surface Hygiene Label (for US Only) 1. If your installation is in the USA, locate the surface hygiene label, like that shown here. 2. Peel off the self-adhesive backing from the label, and affix the label in the center of the upper part of the X-ray Console, as shown below. Affix label here Page no. 413 JC-PHY-A-006.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A006 - Regulatory and Safety Labelling This page is blank. Chapter 6 Page no. 414 JC-PHY-A-006.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A009 - Opposite Side Rotative Arm Installation Job Card PHY A009 - Opposite Side Rotative Arm Installation 1 Chapter 6 SUPPLIES • Spare USB extension cable connected to the Control Station framework below the keyboard. • Left stop bracket (PN 5235174-2) : one ring labeled L. L Note: The left stop bracket (PN 5235174-2) can be found in the Accessories box that is delivered with the Senographe system. The Accessories box (located in the large wooden Accessories cabinet) contains the ADS/IDC Software, Loopback Kit, Service Documents, etc.. 2 • • TOOLS Standard Tool Box Sisfle Rotative Arm Installation Tool (FE supply) 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 1 hour 4 SAFETY PRECAUTIONS None 5 PREREQUISITES None Page no. 415 JC-PHY-A-009.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A009 - Opposite Side Rotative Arm Installation 6 PROCEDURE 1. Carefully pull on the upper silicone mask (1) to remove it from the rotative arm. Store the upper silicone mask in a clean place. 1 2. Carefully pull on the lower silicone mask (2) to remove it from the rotative arm support. Store the lower silicone mask in a clean place. 2 3. Disconnect the mouse cable from the ADS computer. 4. Cut the cable ties that secure the monitor cables and mouse cable to the Control Station framework Chapter 6 Page no. 416 JC-PHY-A-009.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A009 - Opposite Side Rotative Arm Installation (3) and harness (4). 4 3 5. Carefully pull the harness (5) from the upper and lower parts of the rotative arm. 7 5 6. Extract the mouse cable (6) from the hole in the harness, and from the opening of the monitor sup- Page no. 417 JC-PHY-A-009.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A009 - Opposite Side Rotative Arm Installation port (7). Remove the mouse and store it in a clean place. 6 7. Extract the harness from the opening of the monitor support (7). To ease the harness extraction, pull the harness back from the monitor cables and remove the monitor cables from opening of the monitor support in the following order: • Ground cable • DVI video cable • Power cable 8. Remove the monitor cables (8) from the harness, and put the harness in a clean place. 8 9. Pass each of the monitor cables through the opening of the rotative arm support and store them on top of the Control Station keyboard. To do this easily, proceed as described in the following substeps. Chapter 6 Page no. 418 JC-PHY-A-009.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A009 - Opposite Side Rotative Arm Installation a. Thread the ground cable through the opening of the rotative arm support. b. Thread the power cable through the opening of the rotative arm support as shown below. Page no. 419 JC-PHY-A-009.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A009 - Opposite Side Rotative Arm Installation c. Thread the ferrite ring (9) of the DVI video cable inside the rotative arm support. While keeping the DVI connector outside (10) move the DVI video cable to the bottom of the rotative arm support. 9 10 d. Thread the DVI video cable through the opening of the rotative arm support as shown below. Chapter 6 Page no. 420 JC-PHY-A-009.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A009 - Opposite Side Rotative Arm Installation 10. Disconnect the ground cable (11) from the crock. 12 11 11. Remove the two screws (12) (3 mm allen wrench) securing the crock and remove it. 12. Remove the four screws (13) securing the rotative arm support (5 mm allen wrench) and remove it. 13 13 13. Install the rotative arm support on the opposite side of the Control Station and secure it with the same four screws (5 mm allen wrench). To do this easily, use the Sisfle Arm Installation Tool with the following sub-steps: a. Put the two threaded rods the Sisfle Arm Installation Tool into the lower two threads (15). Screw the two threaded rods (14) in a clockwise direction until they no longer move. The right-hand side Page no. 421 JC-PHY-A-009.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A009 - Opposite Side Rotative Arm Installation rod will have some of its thread exposed, as illustrated below. 14 15 b. Slide lower holes of the rotative arm support onto the two threads. Push the acrylic support block (16) from the Sisfle Arm Installation Tool on to the two threaded rods so that the rotative arm is supported. 16 Chapter 6 Page no. 422 JC-PHY-A-009.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A009 - Opposite Side Rotative Arm Installation c. Attach the top two screws (17) to secure the top of the rotative arm support (5 mm allen wrench). 17 18 d. Carefully pull the acrylic support block to remove it from the two threaded rods. Unscrew the two threaded in an anti-clockwise direction to remove them from the Control Station framework. e. Attach the bottom two screws (18) to secure the top of the rotative arm support (5 mm allen wrench). f. Use the torque wrench to tighten the four screws to 9.5 Nm ± 0.5 Nm. g. Apply Blue Loctite 243 around the heads of the four screws. At this stage you cannot re-route the cables. You must change the stop bracket. 14. Turn the allen screw (19) at the joint of the rotative arm clockwise 540° (three full turns), but do not remove it (2.5 mm allen wrench). 19 Page no. 423 JC-PHY-A-009.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A009 - Opposite Side Rotative Arm Installation 15. Remove the large allen screw (20) from the joint of the rotative arm (6 mm allen wrench). 20 16. Place the large allen screw and its washers in a clean place. Ensure that the washers on the large allen screw are positioned as indicated below. Small Black Washers Bending Away From Each Other Medium Black Washer Large Black Washer Small Silver Washers 17. Remove the black plastic washer (21) and keep it close by as you will reinstall it with the left stop bracket. 22 21 22 Chapter 6 Page no. 424 JC-PHY-A-009.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A009 - Opposite Side Rotative Arm Installation 18. Remove the right stop bracket (22) and put it in the bag containing the stop bracket set. 19. Take the left stop braket (labeled with an "L") from the stop bracket set. Place the left stop bracket (23) with its lug facing downwards, so that the lug goes into the hole (24) as shown below. L 23 25 24 20. Reinstall the black plastic washer (25) on top of the left stop bracket. 21. On the upper part of the rotative arm, move the stop bracket screw from its original position to the opposite side (3 mm allen wrench). Original Position : Right Hand Stop Bracket Page no. 425 JC-PHY-A-009.fm New Position :Left Hand Stop Bracket Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A009 - Opposite Side Rotative Arm Installation 22. Put the upper part (26) of the rotative arm back on to the rotative arm support (27). When in close proximity to the left stop bracket (28), ensure that the stop bracket screw (29) fits between the gap on the left stop bracket. 26 28 29 27 23. Put the large allen screw (30) back in place on the joint of the rotative arm (6 mm allen wrench). 30 24. Use the torque wrench to tighten the large allen screw to 1.5 Nm ± 0.5 Nm. 25. Turn the allen screw (31) at the joint of the rotative arm anti-clockwise until it no longer moves (2.5 mm allen wrench). 31 Chapter 6 Page no. 426 JC-PHY-A-009.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A009 - Opposite Side Rotative Arm Installation 26. Pass each of the monitor cables that you stored on top of the Control Station keyboard through the opening of the rotative arm support. To do this easily, proceed as described in the following substeps. a. Thread the DVI video cable through the opening of the rotative arm support as shown below. 33 32 b. Thread the ferrite ring (32) of the DVI video cable inside the rotative arm support. While keeping the DVI connector outside (33) move the DVI video cable to the top of the rotative arm support. 33 32 Page no. 427 JC-PHY-A-009.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A009 - Opposite Side Rotative Arm Installation c. Thread the power cable through the opening of the rotative arm support as shown below. d. Thread the ground cable through the opening of the rotative arm support. 27. Thread the monitor cables (34) through the harness. Ensure that the monitor cables do not cross each other, as shown below. 34 28. Put the harness through the opening of the monitor support (35). To do this, pull the harness back from the monitor cables and insert the monitor cables through the opening of the monitor support in the following order: • Power cable • DVI video cable Chapter 6 Page no. 428 JC-PHY-A-009.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A009 - Opposite Side Rotative Arm Installation • Ground cable 35 36 36 29. Distribute evenly (36) the harness over the monitor cables on both sides of the monitor support. 30. Place the mouse at the back of the mouse support (so that there is enough cable for use of the mouse on the entire mouse support). 31. Use pointed nose pliers to create an opening in the harness at 27 cm from the end of the harness. 27 cm Page no. 429 JC-PHY-A-009.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A009 - Opposite Side Rotative Arm Installation 32. Route the mouse cable through the opening in the harness, so that it leaves the other end of the harness. Then route the track cable through the rotative arm support entrance into the Control Station. 33. Ensure that the length of each of the monitor cables leaving the harness are at the distances as specified below. Secure the harness to the monitor cables with a cable tie located at 1 cm from the end of the harness. Monitor video cable: 26 cm from harness end. Monitor power cable: 26 cm from harness end. Monitor earth cable: 6 cm from harness end. 26 cm 6 cm 34. Install and connect the monitor as described in Job Card PHY A010 - Mount LCD Monitor on Control Station - Procedure on page 436. Chapter 6 Page no. 430 JC-PHY-A-009.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A009 - Opposite Side Rotative Arm Installation 35. Ensure that the rotative arm (37) and rotative arm support (38) are aligned in the same plane (see below). Carefully put the harness inside the rotative arm and rotative arm support. 38 37 Aligned in the same plane. 36. Insert the upper silicone mask (shorter of the two) (39) into the rotative arm. The rounded edge of the silicone mask must point outwards. 39 37. Insert the lower silicone mask (longer of the two) (40) into the rotative arm. The rounded edge of the silicone mask must point outwards. 40 Page no. 431 JC-PHY-A-009.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A009 - Opposite Side Rotative Arm Installation 38. Use the USB extension cable to connect the mouse to the ADS computer. Secure the mouse and USB extension cable connectors with two cable ties (41). 41 39. Ensure that the monitor cables have sufficient slack (42) within the Control Station so that they can move. This ensures that the movement of the monitor cables are not inhibited when the rotative arm is turned. Secure the harness to the monitor cables and mouse cable with a cable tie at 1 cm from the end of the harness (43). Secure the monitor cables and mouse cable to the Control Station framework with a cable tie (44). 43 42 44 Chapter 6 Page no. 432 JC-PHY-A-009.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A009 - Opposite Side Rotative Arm Installation 40. Turn the rotative arm though all extremes, and check that the harness, monitor cables, and mouse cable are free to move as indicated below. 41. When moving the rotative arm through the extreme positions, check that the stop bracket screw (45) is correctly positioned to avoid a collision with the radiation screen. 45 42. Install the crock on the opposite side of the Control Station, secure it with two screws (3 mm allen wrench), but do not tighten the screws. 43. Connect the ground cable to the crock. 44. During reinstallation of the Omega Cover, adjust the position of the crock and tighten the two screws to secure it (3 mm allen wrench). Page no. 433 JC-PHY-A-009.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A009 - Opposite Side Rotative Arm Installation This page is blank. Chapter 6 Page no. 434 JC-PHY-A-009.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A010 - Mount LCD Monitor on Control Station Job Card PHY A010 - Mount LCD Monitor on Control Station 1 Chapter 6 SUPPLIES None 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 15 minutes 4 SAFETY PRECAUTIONS None 5 PREREQUISITES None Page no. 435 JC-PHY-A-010.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A010 - Mount LCD Monitor on Control Station 6 PROCEDURE Note: The Control Station supports 18" and 19" Monitors, and the optional 21" 3 MP Monitor. Follow section 6-1, Mounting an 18" or 19" Monitor for 18" and 19" Monitors. Follow section 6-2, Mounting the optional 21" 3 MP Monitor for the optional 21" 3 MP Monitor. 6-1 Mounting an 18" or 19" Monitor When appropriate, the steps below show images for both arms. 1. Place the monitor on a protected surface. Fix the screen plate to the monitor using washers and two 20 mm screws (1) on the top, and two 16 mm screws (2) on the bottom. 1 2 2. Put the monitor in place (the screen plate adjusted on the sliding pivot). 3. Fix the sliding pivot with the monitor using the four inner screws of 8 mm length (3) (3 mm allen Chapter 6 Page no. 436 JC-PHY-A-010.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A010 - Mount LCD Monitor on Control Station wrench). 3 3 4. Unscrew the screw (4) (screwdriver) which secures the monitor cable protecting plate (5) and remove the cable protecting plate. Sisfle Arm 4 5 5. Connect the ground cable (6) (screwdriver). Page no. 437 JC-PHY-A-010.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A010 - Mount LCD Monitor on Control Station 6. Connect the DVI video cable as follows.. DVI 8 6 7 7. Connect the power supply cable (7) and secure it with a cable clamp (8). 8. Re-install the cable protecting plate (5) while ensuring that the cables pass through the exit without being trapped, and tighten the securing screw (4) (screwdriver). 9. At 17 cm away from the right edge (looking from behind), secure the harness to the back of the LCD monitor with a black cable tie (9). 9 17 cm 10. Perform a monitor collision check. To do this, check that the stop bracket and stop bracket screw (10) is correctly positioned to avoid a collision with the radiation screen. 10 Chapter 6 Page no. 438 JC-PHY-A-010.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A010 - Mount LCD Monitor on Control Station 6-2 Mounting the optional 21" 3 MP Monitor 1. Place the monitor on a protected surface. Fix the screen plate to the monitor using washers and two 20 mm screws (1) on the top, and two 16 mm screws (2) on the bottom. 2 1 2. Put the monitor in place (the screen plate adjusted on the sliding pivot). 3. Fix the sliding pivot with the monitor using the four inner screws of 8 mm length (3) (3 mm allen wrench). 3 3 Page no. 439 JC-PHY-A-010.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A010 - Mount LCD Monitor on Control Station 4. Remove the pre-routed monitor earth cable from the harness, and connect it to the same Earth Bar connector accommodating the cable labelled 5166436. 5. Create a loop with the excess earth cable, and secure the loop with a cable tie (6). 6 Monitor earth cable going down to earth bar Chapter 6 Page no. 440 JC-PHY-A-010.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A010 - Mount LCD Monitor on Control Station 6. Connect the DVI cable (7). 7 8 9 10 7. Connect the power supply cable (8) and secure it with a cable tie (9). 8. Close the top of the harness with a black cable tie (10). 9. Perform a monitor collision check. Check that the stop bracket and stop bracket screw (11) is correctly positioned to avoid a collision with the radiation screen. 11 Note: Later on during the electrical installation phase, remember to perform Job Card ELE A008 - Configuring the 21-inch 3MP Monitor on page 549 so that the ADS software is correctly configured for the 21" 3 MP Monitor. Page no. 441 JC-PHY-A-010.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A010 - Mount LCD Monitor on Control Station This page is blank. Chapter 6 Page no. 442 JC-PHY-A-010.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A011 - Trackball Option Installation Job Card PHY A011 - Trackball Option Installation 1 Chapter 6 SUPPLIES ADS Trackball Kit 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 1 hour 30 minutes 4 SAFETY PRECAUTIONS WARNING Before beginning work, shut down correctly the equipment and switch off the Senographe system hospital supply circuit breaker. Lock it in the off position or mark it clearly with a warning sign to prevent others from applying power. 5 PREREQUISITES Calibrate the Trackball on a laptop in a quiet area (see Job Card ELE A065 - Trackball Configuration on page 787). 6 PROCEDURE 1. Unplug and remove the X-ray Console. 2. Remove the Top Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 3. Remove the Omega Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 4. Carefully pull on the upper silicone mask (1) to remove it from the rotative arm. Store the upper sili- Page no. 443 JC-PHY-A-011.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A011 - Trackball Option Installation cone mask in a clean place. 1 5. Carefully pull on the lower silicone mask (2) to remove it from the rotative arm support. Store the lower silicone mask in a clean place. 2 6. Disconnect the mouse cable from the ADS computer. 7. Cut the cable ties that secure the monitor cables and mouse cable to the Control Station framework Chapter 6 Page no. 444 JC-PHY-A-011.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A011 - Trackball Option Installation (3) and harness (4). 4 3 8. Carefully pull the harness (5) from the upper and lower parts of the rotative arm. 7 5 9. Extract the mouse cable (6) from the hole in the harness, and from the opening of the monitor sup- Page no. 445 JC-PHY-A-011.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A011 - Trackball Option Installation port (7). Remove the mouse. 8 10. Remove the mouse mat (9). 11. While holding the handle (10) Remove the three screws (11) securing the mouse mat support (12) and remove the mouse mat support. 9 11 10 12 12. Secure the handle (10) with the three new screws (13) that are supplied with the Trackball kit. 13 15 10 14 13. Install and secure the trackball with the longest screw (14) (length = 38 mm) and spacer (15) that are supplied with the Trackball Kit. Chapter 6 Page no. 446 JC-PHY-A-011.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A011 - Trackball Option Installation 14. Use pointed nose pliers to create an opening in the harness at 27 cm from the end of the harness. 27 cm 15. Route the trackball cable through the opening in the harness, so that it leaves the other end of the harness. Then route the track cable through the rotative arm support entrance into the Control Station. 16. Ensure that the rotative arm (15) and rotative arm support (16) are aligned in the same plane. Carefully put the harness inside the rotative arm and rotative arm support. 16 15 Aligned in the same plane. 17. Insert the upper silicone mask (shorter of the two) (17) into the rotative arm. The rounded edge of the Page no. 447 JC-PHY-A-011.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A011 - Trackball Option Installation silicone mask must point outwards. 17 18. Insert the lower silicone mask (longer of the two) (18) into the rotative arm. The rounded edge of the silicone mask must point outwards. 18 19. Use the USB extension cable (supplied with the Trackball Kit) to connect the trackball to the ADS Chapter 6 Page no. 448 JC-PHY-A-011.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A011 - Trackball Option Installation computer. Secure the Trackball and USB extension cable connectors with two cable ties (19). 19 20. Ensure that the monitor cables have sufficient slack (20) within the Control Station so that they can move. This ensures that the movement of the monitor cables are not inhibited when the rotative arm is turned. Secure the harness to the monitor cables and trackball cable with a cable tie at 1 cm from the end of the harness (21). Secure the monitor cables and trackball cable to the Control Station framework with a cable tie (22). 21 20 22 Page no. 449 JC-PHY-A-011.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A011 - Trackball Option Installation 21. Turn the rotative arm though all extremes, and check that the harness, monitor cables, and trackball cable are free to move as indicated below. 22. Reinstall the Omega Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 23. Reinstall the Top Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 24. Reinstall the X-ray Console. Chapter 6 Page no. 450 JC-PHY-A-011.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A012 - X-ray Console Cable Routing Job Card PHY A012 - X-ray Console Cable Routing 1 Chapter 6 SUPPLIES None 2 TOOLS Standard Tool Box 3 SAFETY PRECAUTIONS None 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 5 PREREQUISITES None Notice: - To avoid unwanted disconnection, the X-ray Console cable must be fixed to the mechanical structure of the Control Station and the Generator. The external part of the X-ray Console cable must be mechanically protected from damage that could come from unsafe routing in the room. Page no. 451 JC-PHY-A-012.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A012 - X-ray Console Cable Routing 6 PROCEDURE 1. Connect the end of the X-ray Console cable (1) that does not contain a ferrite ring to the XJ8 connector located on the bottom right of the Generator Command Board 400PL1. 1 2 2. Route the X-ray Console cable from the Generator Cabinet as shown. To avoid unwanted disconnection, the X-ray Console must be fixed to the mechanical structure of the Generator. Therefore, use cable ties to secure the X-ray Console cable to the existing cables (2) that are already connected to the Generator Cabinet. 3. Route the other end of the X-ray Console cable (with the ferrite ring) up the back side of the Control Station in close proximity to the other data cables. To avoid unwanted disconnection, the X-ray Console must be fixed to the mechanical structure of the Control Station. Therefore, use cable ties to secure the X-ray Console cable to the Control Station framework (3). 3 Chapter 6 Page no. 452 JC-PHY-A-012.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A012 - X-ray Console Cable Routing 4. Connect the end of the X-ray Console cable (4) to the side of the X-ray Console (5). Put the X-ray Console in place above the keyboard. 4 5 5. Route the excess X-ray Console cable that is between the Control Station and Generator Cabinet beside the cable conduit from the Gantry. When routing the X-Ray Console cable between the Control Station and Generator, ensure that: • it is not kinked and is free from all forms of mechanical stress • it is mechanically protected from damage that could come from unsafe routing in the room, and other objects in the room Page no. 453 JC-PHY-A-012.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A012 - X-ray Console Cable Routing This page is blank. Chapter 6 Page no. 454 JC-PHY-A-012.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A014 - Connect Gantry to Control Station Job Card PHY A014 - Connect Gantry to Control Station 1 Chapter 6 SUPPLIES None 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS None 5 PREREQUISITES None 6 PROCEDURE 6-1 Black Tubular Harness Routing Gantry to Control Station cables are already connected in the Gantry. The harness (Control Station Positioner harness) leaves the Gantry through a black tubular conduit. 1. Run the cable conduit from the Gantry to the control station (through floor or wall ducting as appropriate). 2. The conduit can enter the control station cabinet from either side. If it enters from the left (as viewed from the front), it must pass through the space at the bottom of the cabinet to emerge on the righthand side. 3. Place all of the cables leaving the conduit under the bottom level (you will route them in the next section). 4. Use the clamp provided to secure the conduit to the metal chassis at (A). If the conduit is too long for the cable run, it can be cut. Take care not to damage the cables. Note: At this stage, all of the cables are underneath the bottom level. A Page no. 455 JC-PHY-A-014.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A014 - Connect Gantry to Control Station 6-2 Connecting Cables Coming from the Harness You must connect cables from the harness to the IDC, ADS, UPS, and Ethernet switch as follows: 1. Connect the cables from the harness to the IDC as specified below in the illustration and table. The power and ground cables, and the gray Ethernet cable to the ADS should already be connected. 7 8 1 3 6 4 Empty 5 2 Note: An empty Ethernet port exists to the left hand side of the USB ports. The Ethernet cable from the switch must be connected to the lowest Ethernet port, which is to the left hand side of the IDC - Gantry Conditioner Link. Reference Cable Label Cable Description/Location 1 IDC-SIB 2244615 IDC - Gantry Serial Link RT (1) to 50-pin connector 2 IDC-COM1 2226612 IDC - Gantry Conditioner Link to top right 9-pin COM1 connector 3 IDC-SIB 2226621 IDC - Detector Power Supply to 26-pin connector 4 IDC-COM2 2244615 IDC - Gantry Serial Link RT to COM2 9-pin connector 5 2389288-2 IDC - ADS link via router. Grey 100 Mbit/s Ethernet cable to RJ-45 connector. This should already be connected. 6 IDC I/O 2340426 IDC - Detector link. Two fiber optic cables to fiber optic connectors. Fiber labelled A (white) on the left, yellow on the right. 7 None - Power Cable Power connector from UPS. This should already be connected. 8 None - Earth Cable Earth cable from earth bar. This should already be connected. Chapter 6 Page no. 456 JC-PHY-A-014.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A014 - Connect Gantry to Control Station ! Notice: Fiber-optic cables are more easily damaged than electrical cables; handle them with care. A small protective cap protects the cable end; remove it before connecting. The connectors are keyed; if they are difficult to connect, check that the key is correctly oriented. When disconnecting, be sure to pull on the connector and not on the cable. When making the IDC cable connections, check that the power connector from the UPS and the Ethernet (ADS via router) connector are firmly connected. 2. Connect the following cables from the harness to the UPS. • power cable to the UPS power inlet socket (8) • two gray cables labeled 2387162 which are joined together by one 9-pin connector to the 9-pin serial connector on the UPS (9). 9 10 8 When making the UPS cable connections, check that the three power output connectors (10) from the UPS are firmly connected. Thses output connectors source the IDC, ADS Computer, and power distribution block (located behind and under the X-ray Console) . 3. Connect the following cables (shown in italics in the illustrations) from the harness to the ADS Computer. • the gray Generator-UPS-ADS Serial Link cable labeled 2387162 to the 9-pin serial connector (11) on the ADS Computer • the gray Generator Serial Link cable labeled 2226625 to the 9-pin serial connector (12) on the ADS Computer Page no. 457 JC-PHY-A-014.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A014 - Connect Gantry to Control Station ILLUSTRATION 1 - ADS REAR PANEL CONNECTIONS AC input from UPS Ground Keyboard Mouse Empty Bar Code Empty Scanner Ethernet cable to internal switch (2389288-2) Ethernet cable to hospital network Monitor Cable via DVI-I adaptor Empty 11 – DB9 UPS serial link (2387162) 12 – DB9 Generator serial link (2226625) DB9 Service Key link Note: Ensure that the monitor DVI cable is connected to the left hand side display port (number 1) on the back of the ADS computer. The monitor DVI cable must be connected to the display port via a DVI-I - display port adaptor cable shown below. Chapter 6 Page no. 458 JC-PHY-A-014.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A014 - Connect Gantry to Control Station Note: The monitor DVI cable should already be connected via the DVI-I - display port adapter. However, ensure that it is connected to the left hand side display port connector (labelled number 1) on the back of the ADS computer. 4. All the other cables (i.e. monitor, keyboard, mouse/trackball, service key, Ethernet, and power) should already be connected to the ADS Computer. Ensure that all these cables are still firmly in place. Refer to Illustration 1 on page 458 for more information. Note: A trackball can be provided as an option in place of the mouse. Do not attempt to connect a mouse and trackball simultaneously. 5. Connect the Ethernet cable labeled 2385966 from the harness (originating from the Gantry CPU) to port 3 on the Ethernet switch. Page no. 459 JC-PHY-A-014.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A014 - Connect Gantry to Control Station 6-3 Securing the Cables You must minimize the possibility of problems due to electromagnetic interference. The power, Ethernet, and data cables from the harness conduit must be run separately, and secured to the Control Station framework with cable ties as follows: • IDC, ADS and UPS data cables are secured to the back metallic cable support (A). • UPS AC supply input cable, Control Station ground cable, and the other pre-connected IDC and AWS power cables are connected to the front metallic cable support (B). • When connecting the Gantry Ethernet cable (C) to port 3 of the switch (i.e. directly below the pre-connected Ethernet cables going to IDC and ADS), secure the Ethernet cables from the Gantry, IDC and ADS with the ferrite block (D). Make a figure of eight with any access Ethernet cable, and secure the excess Ethernet cable behind the securing plate (E) with a cable tie (F). When securing the Ethernet cables, make sure they are not in contact with the pre-routed AC/earth cables (G) that are secured to the front metal support. A B A E F D C G Chapter 6 Page no. 460 JC-PHY-A-014.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A014 - Connect Gantry to Control Station 6-4 Distribution of AC Power Check that power inputs to the Control Station component components are correctly connected to the UPS AC power outputs. The Control Station components include the AWS, IDC, Ethernet switch, and LCD Monitor. 6-5 Routing and Connection of Earth Cable Route the Earth Cable from the Gantry up the front matellic cable support (A) and connect it to the Control Bar (B) as indicated below. B A B A A Page no. 461 JC-PHY-A-014.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A014 - Connect Gantry to Control Station 6-6 Network Connections Connect the Hospital Ethernet network cable to the lower RJ-45 socket on the rear panel of the ADS Computer. Lower RJ-45 Socket Cable Tie Buckle Use a cable tie to secure the Hospital Ethernet network cable to the Gantry Harness. So that the Hospital Ethernet network cable is hidden under the Gantry Harness and protected from the Omega Cover, ensure that the buckle of cable tie is buckle is rotated as far as possible clockwise. Chapter 6 Page no. 462 JC-PHY-A-014.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A014 - Connect Gantry to Control Station 6-7 UPS Battery Connection The battery plug to the UPS is not connected at delivery time. Firmly connect the battery plug to the battery on the UPS as shown below. UPS battery disconnected at delivery time Connect UPS battery as shown below Battery Connection Page no. 463 JC-PHY-A-014.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A014 - Connect Gantry to Control Station 7 CONTROL STATION BLOCK DIAGRAM 7-1 Control Station Data Distribution Diagram Hospital Network HARDWARE KEY Keyboard Mouse 2387162 Monitor AC AC AC AC COM2 RJ45 AC IN RJ45 Service Network Connection COM1 5177284-2 SIB 26pts IDC AC SIB 50pts OF UPS DVI AC AC AC AC 2340426 ETHERNET To Generator (MDR) RJ45 To Gantry 4X 3X 2X 1X net0 1 2 To Generator To Detector Optical Fiber Socket 2226612 USB net1 To Detector Power Supply To Conditioner 2244615 USB To Generator Z400 PCIe2 DVI-I adaptor PCI1 PCI0 SWITCH AC 2244615 2226621 2226625 2387162 2385966 Chapter 6 Page no. 464 JC-PHY-A-014.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A014 - Connect Gantry to Control Station 7-2 Control Station Power Distribution Diagram Monitor AC AC UPS OUT AC AC AC AC AC IDC AC AC IN AC Z400 USB USB net1 net0 1 ETHERNET SWITCH 2 PCIe2 PCI1 PCI0 AC 2385793 2385960 Page no. 465 JC-PHY-A-014.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A014 - Connect Gantry to Control Station This page is blank. Chapter 6 Page no. 466 JC-PHY-A-014.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A015 - HT Cable Connection Job Card PHY A015 - HT Cable Connection 1 Chapter 6 SUPPLIES HV grease 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 10 minutes 4 SAFETY PRECAUTIONS Ensure that no AC power is applied to the system when performing this procedure. 5 PREREQUISITES None 6 PROCEDURE CAUTION The HT block and kV/mA board assembly is factory calibrated. Do not attempt to adjust potentiometer P1 (HT probe frequency compensation). 6-1 HT Cable Connection The system is shipped with the HT cable disconnected and the air vent screw closed. 1. Locate the HT probe cable. Carefully release and remove its protective covers and any cable ties, etc., which have been used to secure it during delivery. 2. Locate the HT cable receptacle on the HT block. Carefully remove its protective covering. 3. Use HV grease to lightly grease the HT cable probe. Insert the probe into its receptacle. Page no. 467 JC-PHY-A-015.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A015 - HT Cable Connection 4. Use a suitable pin wrench to tighten the cable securing nut (1) until resistance is felt. Try to move the probe by hand. If any movement is possible, tighten the nut further. Continue until no movement is detected. 2 1 5. The tank air vent screw (2) must be slightly open, to ensure that no excess pressure builds up during long exposures. Tighten the screw by hand, then unscrew it to leave a 3 mm (1/8 inch) gap. Do not remove the screw. Chapter 6 Page no. 468 JC-PHY-A-015.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A016 - AC Connection Job Card PHY A016 - AC Connection 1 Chapter 6 SUPPLIES None 2 TOOLS • • Multimeter (Fluke 87) Standard Tool Box Note: The recommended torque for all lug nuts is 4 Nm. 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS Follow standard safety techniques and procedures for handling equipment and circuits carrying AC supply voltages. 5 PREREQUISITES A suitable mains isolator switch must have been installed for connection of the Senographe system to the hospital supply. ! Notice: Jumpers and switches not dependent on site voltages etc. are set in the factory. However, they must be checked in case they have been disturbed. Refer to sections 2-1 and 2-3 in the System Description Chapter to ensure that the jumpers on the Generator CPU Board and Command Board are correctly set. You will configure the jumpers on the Generator Command Board later on according to Job Card PHY A018 - Room Lamps and Door Configuration on page 475. Notice: - 6 To avoid unwanted disconnection, the Line Supply Cable must be fixed to the mechanical structure of the Generator. External cables must be mechanically protected from damage that could come from unsafe routing in the room. PROCEDURES The procedures described in this document and listed below must be followed carefully before applying power to the system: 1. AC Supply Check. 2. Voltage Selection - Mains Distribution Rack. 3. Voltage Selection - Generator. 4. Configure Fuses F1, F2. 5. Connect the AC Supply Cable. Page no. 469 JC-PHY-A-016.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A016 - AC Connection 6-1 AC Supply Check Determine the nominal voltage and frequency of the available power supply. 6-1-1 Check the Nominal Line Voltage Consult the hospital electrician to determine the nominal line voltage and frequency. Then use the multimeter to measure the open-circuit line voltage to check that it corresponds to the nominal line voltage, ±10%. Allowable nominal line voltages are 200 V, 208 V, 220 V, and 240 V. 6-1-2 Line Frequency The Senographe operates with line frequencies of 50 Hz or 60 Hz without adjustment. 6-2 Voltage Selection - Mains Distribution Rack Check the position of the input connection wire on the Mains Distribution Rack transformer terminal block (reference A in the illustration). W1 MAINS LINE2/N Cable W2 TRANSFOR LINE1 Cable A Label on top of transformer indicates terminal positions If the tap connection does not correspond to the nominal (not the measured) line voltage you determined in section 6-1, remove and reconnect the W2 TRANSFOR LINE 1 cable to the correct terminal (200 V, 208 V, 220 V, 230 V, or 240 V). Do not change the position of W1 MAINS LINE 2/N cable, as it must always be on the 0 V terminal. Chapter 6 Page no. 470 JC-PHY-A-016.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A016 - AC Connection 6-3 Voltage Selection - Generator 6-3-1 Check Position of the Voltage Selection Board The voltage selection board IN2 on the AC Distribution board 200–PL1 should already be installed in the correct BT position by manufacturing. Ensure that the voltage selection board IN2 is in the correct position. 6-3-2 IN2 board on left hand side Voltage positions for SEL wire Voltage Selection CAUTION 380 VAC or 415 VAC coupling which was possible with the Senographe 2000D is not possible with the Senographe DS. If you choose this coupling, you will destroy the Gantry power supply. Check the position of the SEL wire on the AC Distribution board 200–PL1 (see illustration). By default, the SEL wire is connected to the 240 V transformer tap. If the tap connection does not correspond to the nominal (not the measured) line voltage you determined in section 6-1, remove and reconnect the SEL wire to the correct terminal (see Table 1). ! Notice: The SEL wire must not be connected to the 0V terminal. This terminal is reserved exclusively for use while performing the measurement described in Installation Job Card Line Resistance Measurement. The Senographe cannot function normally with the SEL wire in this position. TABLE 1 - POSITION OF VOLTAGE SELECTION BOARD IN2 AND SEL WIRE Voltage Selection made in the Mains Distribution Rack Nominal single phase line voltage Position of IN2 Position of SEL wire * 230 V or 240 V 240 V BT 240 V 220 V 220 V BT 220 V 208 V 208 V BT 208 V 200 V 200 V BT 200 V * - If the mains supply is 230 V or above, choose 240 V on the AC Distribution Board 200-PL1. If the mains supply is between 220V and 230V, choose 220V on the AC Distribution Board 200-PL1. Page no. 471 JC-PHY-A-016.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A016 - AC Connection 6-4 Configure Fuses F1, F2. To configure these fuses (see illustration 2 for location), follow the indications on the label located on the bottom of the Generator cabinet, just below the AC supply switch S1. WARNING For safe operation of the Senographe, pay particular attention to the information on this label. Determine whether the AC supply consists of two phases (phase/phase), or a single phase and neutral (phase/neutral). When the supply is single–phase with neutral (phase/neutral), a metal cylinder (delivered with the system) must be installed instead of F1. ILLUSTRATION 1 - LOCATION OF FUSES F1 Chapter 6 Page no. 472 JC-PHY-A-016.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A016 - AC Connection 6-5 Connecting the AC Supply Cable 1. Check that Generator AC supply switch 200-S1 is in the 0 position and that AC supply is off. 2. Connect the wires of the AC supply cable (two phases, or phase and neutral) to the L and N terminals, and the ground wire to the yellow/green terminal, as shown in illustration 2. ILLUSTRATION 2 - CONNECTING THE AC SUPPLY CABLE AC supply cable 200 PL1 HV tank 701 200 PL4 200 PL2 3. Use a cable tie to secure the AC supply cable to the lower cross-member of the Generator framework. Cable Tie 4. Route and connect the other end of the AC supply cable to the AC supply source. Page no. 473 JC-PHY-A-016.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A016 - AC Connection This page is blank. Chapter 6 Page no. 474 JC-PHY-A-016.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A018 - Room Lamps and Door Configuration Job Card PHY A018 - Room Lamps and Door Configuration 1 Chapter 6 SUPPLIES The necessary hardware (wires, lamp, switches, etc.) is field and/or customer supplied. 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 40 minutes 4 SAFETY PRECAUTIONS None 5 PREREQUISITES None 6 PROCEDURE 1. Refer to Illustration 1; connect the room and lamp wiring to XJ1, XJ2, XJ3 on the 200PL4 board (see Illustration 2 for locations). 2. Route the wires in the generator cabinet, along with the mains supply cable. ILLUSTRATION 1 - ROOM LAMPS AND DOOR WIRING GENERATOR Board 200PL4 CUSTOMER-SUPPLIED HARDWARE AC or DC 30 V max K1 Seno ON lamp XJ1 AC or DC 30 V max K2 X-ray ON lamp XJ2 K3 ~ XJ3 Room door switch 24v AC (external power supply) Note: For safety reasons, the electrical source for the Seno ON and X-ray ON lamps must be no more than 30 V. You cannot use a 250 V source under any circumstances. Page no. 475 JC-PHY-A-018.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A018 - Room Lamps and Door Configuration 3. Locate board 400-PL1. Refer illustration 3; and set jumpers JP1 and JP2 as required according to the table below. Place unused jumpers in the parking positions JP3 and JP4. Note: If there is no door switch, jumpers JP1 and JP2 must both be present (case 4 in the table). TABLE 1 - JP1 AND JP2 JUMPER SETTINGS JP1 (RADIOGRAPHY) JP2 (PREP) Door closed Door opened 1 0 0 PREP and RADIOGRAPHY enabled PREP and RADIOGRAPHY disabled 2 1 0 PREP and RADIOGRAPHY enabled PREP and RADIOGRAPHY disabled. NOTE: if the door opens during an exposure, the exposure is not aborted and completes normally) 3 0 1 PREP and RADIOGRAPHY enabled PREP enabled RADIOGRAPHY disabled 4 1 1 PREP and RADIOGRAPHY enabled PREP and RADIOGRAPHY enabled 0 = No jumper 1 = Jumper present Note: When the room door switch is present and configured for use, the signals valid-PR (first trigger or prep) and valid-GR (RADIOGRAPHY) are enabled through the switch. Chapter 6 Page no. 476 JC-PHY-A-018.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A018 - Room Lamps and Door Configuration ILLUSTRATION 2 - LOCATION OF ROOM WIRING CONNECTORS XJ1 Room XJ2 lamps and door XJ3 wiring 200 PL4 ILLUSTRATION 3 - LOCATION OF JP1 TO JP4 Page no. 477 JC-PHY-A-018.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A018 - Room Lamps and Door Configuration This page is blank. Chapter 6 Page no. 478 JC-PHY-A-018.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection Job Card PHY A030 - Generator and Gantry Disconnection Reconnection 1 Chapter 6 SUPPLIES Cable ties (during the reconnection phase) 2 TOOLS Standard Tool Box 3 APPLICABILITY Use this Job Card when you cannot transport the Generator and Gantry together due the physical constraints of the corridors/elevators on a hospital site. 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 60 minutes (20 minutes to disconnect and 40 minutes to reconnect) 5 SAFETY PRECAUTIONS None 6 PREREQUISITES Read the sub-sections to understand the nature of the connections that you are about to remove. 6-1 Summary of Connections The following table summarizes all of the connections on the Generator that you need to disconnect and then reconnect once the equipment is in the desired hospital room. The thick line indicates the separation between the upper part of the Generator and lower part of the Generator. You can use the D and R columns in this table to mark-off when you have disconnected and reconnected the appropriate cable. Note: The not applicable (N/A) entry for the HV Cable means that the HV Cable is not connected when it arrives. However, you have to cut any associated cable ties that secure the HV Cable. The C column indicates which conduit (1 or 2) the cable originates from. Page no. 479 JC-PHY-A-030.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection Cable description or label Conditioner Unit In Red coolant pipe (no label) Out Red coolant pipe (no label) RS-232 Gray cable with the 9-pin D-type connector, labeled Cond. Cab. Cond. 2226611 * XP4 Black power cable with the IEC type 320 female end, labeled XJ4 Cond. Cab. 2225470 XP5 Black power cable with the IEC type 320 female end, labeled XP5 Cond. Cab. 2386021 XJ4 Gray cable with the 9-pin D-type connector, labeled XJ4 GENE 400 PL2 2226623 * XJ10 Blue cable with the 25-pin D-type connector, labeled XJ10 GENE 400 PL2 2226613 XJ6 Black optical fiber labeled 400 PL2 XJ6 2381702 XJ7 Black optical fiber labeled 400 PL2 XJ7 2381704 XJ9 Black optical fiber labeled 400 PL2 XJ9 2381706 XJ1 Blue cable with labeled PH2, originating from a thick white cable labeled 2381711 XJ3 Pink cable with labeled PH1, originating from a thick white cable labeled 2381711 Power Line Filter Box Earth Green/yellow earth cable, originating from a thick white cable labeled 2381711 Supply Command Board 200PL2 Bolt above XJ1 Black cable with blue plastic end, originating from white cable labeled Gene W125 - 2381710 TP10 Black cable with red plastic end, originating from white cable labeled Gene W125 - 2381710 Anode Starter Board 300PL2 XJ2 Gray cable labeled G300-PL2 XP1 2381701 with exposed shielding ending with three black cables to a black connector. Auto Transformer Orange block to BR1 Black cable, originating from white cable labeled Gene W125 - 2381710 Orange block to TH1 Black cable, originating from white cable labeled Gene W125 - 2381710 Earth symbol Thin black cable with red plastic end, labeled HT+ GND / 2381701 N/A HV Cable MDR Generator Interface Board 400PL2 Mains Distribution Board 200PL1 HV Tank C D R N/ A N/ A From Conduit 1 (see section 6-2) Connection From Conduit 2 (see section 6-3) Location within Generator Notes: * - Because there are two cables with the same 9-pin D-type connector originating from the same conduit, you must pay special attention to ensure that you re-connect them to the correct place. Chapter 6 Page no. 480 JC-PHY-A-030.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection 6-2 Conduit 1 Conduit 1 runs up the back side of the Generator, secured by cable ties. The cables/pipes leave conduit 1 in close proximity to the Conditioner unit. They are routed to within the upper and lower parts of the Generator as illustrated below. Conditioner Unit Cond. Cab. Cond. 22266611 RS-232 (9-Pin) Coolant Pipe In Out Coolant Pipe MDR XJ4 Cond. Cab. 2225470 XP4 XP5 Cond. Cab. 2386021 XP5 Conduit 1 Upper Part of Generator Generator Interface Board 400PL2 XJ10 GENE 400PL2 2226613 XJ10 XJ4 GENE 400PL2 2226623 XJ4 Page no. 481 JC-PHY-A-030.fm Lower Part of Generator Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection 6-3 Conduit 2 Conduit 2 is secured to the bottom of the Gantry with a Generator cable bracket that is fixed to the side Generator. The cables leave conduit 2 in close proximity to the HV Tank and are routed to lower parts of the Gantry as illustrated below. HV Tank Black Cable - No Label Red Earth HV Connector HV Cable labeled 2379842 REV 01 Cross indicates that the HV Cable is not connected in this Job Card, but in Job Card PHY A015 - HT Cable Connection on page 467 G300-PL2 XP1 (2381701) Anode Starter 300PL2 XJ2 Generator Interface Board 400PL2 400 PL2 XJ6 2381702 Black conduit containing three optical fibers 400 PL2 XJ7 2381704 400 PL2 XJ9 2381706 Conduit 2 XJ6 XJ7 XJ9 Orange Coupling Block Gene W125 - 2381710 Black To BR1 Black To TH1 Black Blue Bolt above XJ1 Black Red PT10 Supply Command Board 200PL2 Power Line Filter Box Green/Yellow Earth Off-white Gantry AC Supply cable labeled 2381711 Pink PH1 Blue PH2 Earth XJ3/PH1 XJ1/PH2 Mains Distribution Board 200PL1 Chapter 6 Page no. 482 JC-PHY-A-030.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection 7 GENERATOR DISCONNECTION PROCEDURE Use the following steps to disconnect the Gantry connections from the various parts of the Generator: 1. Remove the four Generator side panels (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513) to reveal the inside of the Generator. 2. Remove the cable ties (1) then from the Generator Interface Board 400 PL2, disconnect the cables from the XJ4 and XJ10 connectors. XJ4 1 XJ10 Page no. 483 JC-PHY-A-030.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection 3. Remove the cable ties (2) that secure the cables/coolant pipes (3) from the Gantry to the framework. Then un-ravel the cables/coolant pipes (3) from the Gantry from the side of the chiller. 3 2 4. Disconnect the two coolant pipes (4) from the Conditioner In and Out connectors, and disconnect IDC data cable connection (5) from the Conditioner RS-232 connector. 5 4 5. Remove the cable ties (6) and disconnect the two power connectors (7) from the MDR XP4 and XP5 Chapter 6 Page no. 484 JC-PHY-A-030.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection connectors. 7 6 6. Group together the coolant pipes, power cables, and data cables that you disconnected during steps 2 to 5. You will connect these back to the Conditioner, MDR, and Generator Interface Board 400 PL2 later on once the equipment is in the hospital room. 7. On the Generator Interface Board 400 PL2, disconnect the three optical fibers from the XJ6, XJ7, and XJ9 connectors. XJ6 XJ7 XJ8 XJ9 8. Remove the cable tie (8) securing the Gene W125 - 2381710 cable at the top left of the Supply ComPage no. 485 JC-PHY-A-030.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection mand Board 200 PL2. 9. On the Supply Command Board 200 PL2, disconnect the black cables from the TP10 connector and the top left bolt connection (ground) (8 mm open-ended wrench). These black cables originate from the Gene W125 - 2381710 cable 8 Ground TP10 10. From the orange coupling block (9) that connects to the BR1 and TH1 connections on the Auto Transformer, remove the two black cables (10) (small screwdriver). The two black cables originate from the Gene W125 - 2381710 cable. 9 10 If necessary, slide the orange coupling block from the Auto Transformer to access the screws. Chapter 6 Page no. 486 JC-PHY-A-030.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection 11. Remove the cable ties securing the white Gantry AC Supply cable (labeled 2381711) to the HV Unit (11) and the cables near the Power Line Filter Box (12). 11 12 Page no. 487 JC-PHY-A-030.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection 12. At the back of the Power Line Filter Box (13), remove the Earth cable (14) (8 mm open-ended wrench). The Earth cable originates from the white Gantry AC Supply cable (labeled 2381711). 14 13 13. On the Mains Distribution Board 200 PL1, disconnect the cables PH2 and PH1 from the XJ1, XJ3 connectors (8 mm open ended wrench). The cables PH2 and PH1 originate from the white Gantry AC Supply cable (labeled 2381711). XJ3 XJ1 Chapter 6 Page no. 488 JC-PHY-A-030.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection 14. On the Anode Starter Board 300PL2, remove the cable labeled G300-PL2 XP1 2381701 from the XJ2 connector. XJ2 15 15. Remove the cable labeled G300-PL2 XP1 2381701 from the framework of the Generator by releasing the clamp (15) that secures it to the framework (4 mm allen wrench). Page no. 489 JC-PHY-A-030.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection 16. If necessary, cut the cable ties that secure the HV Cable (16) to the framework. At this stage, it is not already connected in the HV Tank. 16 17. On the HT block, disconnect the X-ray Tube Housing Return Cable (8 mm open-ended wrench). This cable is the black cable with the red plastic ending (17), labeled HT+ GND / 2381701. 17 18. Group together the cables that you disconnected during steps 7 to 17. You will fully remove them from the Generator by releasing the Generator cable bracket in the following steps. You will connect these back to the lower parts of the Generator later on once the equipment is in the hospital room. Chapter 6 Page no. 490 JC-PHY-A-030.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection 19. Release the two allen screws (18) (4 mm allen wrench) that secure the Generator cable bracket (19) to the Generator framework. Remove the Generator cable bracket from the Generator. 19 18 Keep the two allen screws in a safe place as you will use them again later on to re-connect the Generator Cable bracket to the Generator framework. Page no. 491 JC-PHY-A-030.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection 8 GENERATOR RECONNECTION PROCEDURE Use the following steps to reconnect the Gantry connections to the various parts of the Generator: 1. Secure the Generator cable bracket (1) to the Generator framework with the two allen screws (2) (4 mm allen wrench) . 1 2 2. On the HT block, connect the X-ray Tube Housing Return Cable to the earth connector (8 mm openended wrench). This cable is the black cable with the red plastic ending (3), labeled HT+ GND / 2381701. 3 Horizontal Side Bar 3. Except for the HV cable, ensure that all of the cables leaving conduit 2 are routed underneath the Generator framework horizontal side bar. Chapter 6 Page no. 492 JC-PHY-A-030.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection 4. On the Anode Starter Board 300PL2, connect the cable labeled G300-PL2 XP1 2381701 to the XJ2 connector. XJ2 4 5. Secure the cable labeled G300-PL2 XP1 2381701 to the Generator framework with the clamp (4) (4 mm allen wrench). In order to avoid EMC interference, ensure that the clamp is firmly secured to the exposed shielding on the cable labeled G300-PL2 XP1 2381701. Page no. 493 JC-PHY-A-030.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection 6. On the Mains Distribution Board 200 PL1, connect the cables PH2 and PH1 to the XJ1, XJ3 connectors (8 mm open-ended wrench). The cables PH1 and PH2 originate from the white Gantry AC Supply cable (labeled 2381711) . XJ3 XJ1 Chapter 6 Page no. 494 JC-PHY-A-030.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection 7. At the back of the Power Line Filter Box, connect the Earth cable (6) to the earth connector (5) (8 mm open-ended wrench). The Earth cable originates from the white Gantry AC Supply cable (labeled 2381711). 6 5 8. Ensure that the white Gantry AC Supply cable (labeled 2381711) (7) is routed as shown below. Use cable ties to secure it to the HV Unit (8) and the cables near the Power Line Filter Box (9). 8 9 7 Page no. 495 JC-PHY-A-030.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection 9. Attach a cable tie (8) to secure the Gene W125 - 2381710 cable at the top left of the Supply Command Board 200 PL2. 8 Ground TP10 10. On the Supply Command Board 200 PL2, connect the black cable with the blue plastic end to the top left bolt connection (ground) (8 mm open-ended wrench). The black cable with the blue plastic end originates from the Gene W125 - 2381710 cable. 11. On the Supply Command Board 200 PL2, connect the black cable with the red plastic end to the TP10 connector. The black cable with the red plastic end originates from the Gene W125 - 2381710 cable. 12. Connect the remaining two black cables (9) that originate from the Gene W125 - 2381710 cable to the orange coupling block (10) (small screwdriver). The polarities of these two connections are not important since the other end at the Gantry is a push button switch. 11 10 9 11 10 9 Chapter 6 Page no. 496 JC-PHY-A-030.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection 13. Ensure that the orange coupling block is securely positioned on the L-shaped bracket located on the Auto Transformer (11). 14. On the Generator Interface Board 400 PL2, connect the three optical fibers to the XJ6, XJ7 and XJ9 connectors as summarized in the diagram and table below. XJ6 XJ7 XJ8 XJ9 Connector Label Description of cable (usually identified by code on a white label) Cable color XJ6 400 PL2 XJ6 (optical fiber) Black XJ7 400 PL2 XJ7 (optical fiber) Black XJ8 Empty (optical fiber blank cover) N/A XJ9 400 PL2 XJ9 (optical fiber) Black Note: At this stage, the connectors XJ4 and XJ10 are still disconnected on the Generator Interface Board 400 PL2. This is normal as the two cables that make these connections are from conduit 1, which are routed in the following steps. Page no. 497 JC-PHY-A-030.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection 15. Route conduit 1 and secure it with cable ties as summarized in the diagram below. Route the two coolant pipes to the upper part of the Generator. End of conduit 1 at bottom right corner of Conditioner area. Cable tie to secure the middle of the coolant tube loop. Route the following cables to the upper part of the Generator: - the two power cables labeled XJ4 Cond. Cab. 2225470 and XP5 Cond. Cab. 2386021 - the data cable labeled Cond. Cab. Cond. 2226611 Cable tie to conduit 1 to the Generator framework. Route the two cables labeled XJ4 GENE 400 PL2 2226623 and XJ10 GENE 400 PL2 2226613 to the lower part of the Generator. Cable tie to conduit 1 to the Generator framework. Conduit 1 underneath Generator cable bracket. Chapter 6 Page no. 498 JC-PHY-A-030.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection 16. Connect the black power cables labeled XJ4 Cond. Cab. 2225470 and XP5 Cond. Cab. 2386021 to the MDR XP4 and XP5 connectors, respectively. XP4 XP5 12 17. Secure these two power cables to the MDR with the cable ties (12). 18. Route the power cables along the edge of the Generator framework (13) and secure any remaining slack with cable ties (14). 14 13 Page no. 499 JC-PHY-A-030.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection 19. Connect the two coolant pipes (15) to the Conditioner In and Out connectors. 16 15 20. Connect IDC data cable (16) labeled Cond. Cab. Cond. 2226611 to the Conditioner RS-232 connector. 21. On the Generator Interface Board 400 PL2, connect the cables labeled XJ4 GENE 400 PL2 2226623 and XJ10 GENE 400 PL2 2226613 to the XJ4 and XJ10 connectors, respectively. XJ4 XJ10 Chapter 6 Page no. 500 JC-PHY-A-030.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection 22. Secure and route the cables on the side of the Generator as shown in the diagram below. Secure the two cables labeled XJ4 GENE 400 PL2 2226623 and XJ10 GENE 400 PL2 2226613 going to the lower part of the Generator with cable ties. Secure the cable labeled XJ4 GENE 400 PL2 2226623 from conduit 1 and the optical fibers from conduit 2 together. Secure the two cables labeled XJ4 GENE 400 PL2 2226623 and XJ10 GENE 400 PL2 2226613 from conduit 1 and the optical fiber conduit from conduit 2 together. Page no. 501 JC-PHY-A-030.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A030 - Generator and Gantry Disconnection Reconnection This page is blank. Chapter 6 Page no. 502 JC-PHY-A-030.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A040 - Remove/Reinstall Control Station Covers Job Card PHY A040 - Remove/Reinstall Control Station Covers 1 Chapter 6 SUPPLIES None 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 10 minutes to remove and 10 minutes to reinstall 4 SAFETY PRECAUTIONS WARNING Before beginning work, shut down the equipment and switch off the Generator hospital supply circuit breaker. Lock it in the off position or mark it clearly with a warning sign to prevent others from applying power. Never switch off at the UPS except in emergency (risk of data loss). 5 PREREQUISITES Unplug and remove the X-ray Console. 6 REMOVAL & REINSTALLATION OF V2/V3/V4 CONTROL STATION COVERS 6-1 Top Cover Disassembly To remove the top cover on V2/V3/V4 Control Stations: 1. Remove the three screws (1) securing the bar (4 mm allen wrench) on the blue top cover and remove the bar. 1 Page no. 503 JC-PHY-A-040.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A040 - Remove/Reinstall Control Station Covers 2. Carefully slide the blue top cover towards you to remove it. 6-2 Omega Cover (Front Cover) Disassembly 1. If the radiation screen is present, remove the main frame-radshield joint (1). 1 2 2. Use a screwdriver to remove all the screw covers (2) from the fixing points of the edge pinches. 3. On one edge pinch, loosen the two screws (3) and remove the two screws (4). 3 4 Chapter 6 Page no. 504 JC-PHY-A-040.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A040 - Remove/Reinstall Control Station Covers 4. Remove the edge pinch and its pinch plate. 5. Remove the two screws (5) securing the same side of the Omega cover (3 mm allen wrench). Then release the Omega cover from the back of the Control Station. 5 6. If the radiation screen is present, re-install the edge pinch that you previously removed in steps 3 and 4 and secure it with two screws (6). 6 7. If the radiation screen is present, carefully introduce the pinch plate (7) between the edge pinch and Page no. 505 JC-PHY-A-040.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A040 - Remove/Reinstall Control Station Covers the radiation screen. 7 8 8. If the radiation screen is present, tighten with moderation the two screws (8). 9. Repeat steps 2 to 4 and 6 to 8 for the Omega cover on the other side of the Control Station. 10. Disconnect the ground cable from the right-hand side of the Omega cover. Chapter 6 Page no. 506 JC-PHY-A-040.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A040 - Remove/Reinstall Control Station Covers 11. Carefully move up the Omega cover towards you to remove it. 6-3 Omega Cover Reassembly 1. Carefully put the Omega cover into position on the Control Station. Page no. 507 JC-PHY-A-040.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A040 - Remove/Reinstall Control Station Covers 2. Connect the ground cable to the right-hand side of the Omega cover. 3. On one edge pinch, loosen the two screws (1) and remove the two screws (2). 1 2 4. Remove the edge pinch and its pinch plate. 5. Attach the two screws (3) to secure the same side of the Omega cover (3 mm allen wrench) to the Chapter 6 Page no. 508 JC-PHY-A-040.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A040 - Remove/Reinstall Control Station Covers back of the Control Station. 5 6. If the radiation screen is present, re-install the edge pinch that you previously removed in steps 3 and 4 and secure it with two screws (6). 6 7. If the radiation screen is present, carefully introduce the pinch plate (7) between the edge pinch and the radiation screen. 7 8 8. If the radiation screen is present, tighten with moderation the two screws (8). Page no. 509 JC-PHY-A-040.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A040 - Remove/Reinstall Control Station Covers 9. Repeat steps 4 to 8 for the Omega cover on the other side of the Control Station. 10. Attach all the screw covers (9) to the fixing points of the edge pinches. 10 9 11. If the radiation screen is present, attach the main frame-radshield joint (10). 12. Ensure that the Control Station covers have been correctly fastened and all blanking disks are correctly installed. 6-4 Top Cover Reassembly 1. Carefully slide the blue top cover on to the top of the Control Station. Ensure that its three holes are aligned with the three threaded holes on the Control Station framework.. 2. Use the three screws (1) to secure the bar (4 mm allen wrench) and the blue top cover on to the Control Station. 1 3. Ensure that the Control Station top cover has been correctly fastened. Chapter 6 Page no. 510 JC-PHY-A-040.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A040 - Remove/Reinstall Control Station Covers 7 REMOVAL & REINSTALLATION OF V1 CONTROL STATION COVERS 7-1 Omega Cover (Front Cover). 1 To remove the Omega cover on V1 Control Stations: 1. Remove the four external screws (2) (3 mm allen wrench) securing the Omega cover. 2. Release the cover by tilting it towards you. 3. Remove the front cover by pulling. 4. Disconnect the ground connections. Reverse the procedure to replace the cover. 7-2 2 Top Cover CAUTION Be careful not to damage the fragile upper corner of the top cover. To remove the top cover: 1. Remove the omega cover (see above). 2. Unplug and remove the X-ray Console. 3. Remove the three front securing screws (4) (3 mm allen wrench). 4. Release the cover by tilting it towards you. 5. Remove the top cover by lifting. 3 Reverse the procedure to replace the cover. Ensure that the Control Station covers have been correctly fastened and all blanking disks are correctly installed. Remember to reconnect all ground connections! Page no. 511 JC-PHY-A-040.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A040 - Remove/Reinstall Control Station Covers This page is blank. Chapter 6 Page no. 512 JC-PHY-A-040.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A042 - Remove/Reinstall Generator Covers Job Card PHY A042 - Remove/Reinstall Generator Covers 1 Chapter 6 SUPPLIES None 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 5 minutes to remove covers, and 5 minutes to reinstall covers 4 SAFETY PRECAUTIONS WARNING Before beginning work, shut down the equipment and switch off the Generator hospital supply circuit breaker. Lock it in the off position or mark it clearly with a warning sign to prevent others from applying power. Never switch off at the UPS except in emergency (risk of data loss). 5 PREREQUISITES None Page no. 513 JC-PHY-A-042.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A042 - Remove/Reinstall Generator Covers 6 REMOVAL AND REINSTALLATION OF COVERS 6-1 Remove Generator Covers 1. Remove all power from the Senographe. 2. Remove the four plastic blanking disks (1) (slim flat blade) in each corner of the Generator top cover to expose the screws that secure the Generator top cover. 1 1 1 1 3. Remove the four allen screws (2) that secure the Generator top cover (5.5 mm allen wrench). 2 2 2 Chapter 6 2 Page no. 514 JC-PHY-A-042.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A042 - Remove/Reinstall Generator Covers 4. Remove the earth cable (3) from the Generator top cover and leave it to rest on the Conditioner Unit. Then remove the Generator top cover from the Generator Cabinet. 3 The front and back covers (wider covers) must be removed before you can remove the left and right covers. 5. For the front and back covers, do the following: a. Remove the two bolts (4) that secure the top of the cover (7 mm open ended wrench) and pull it towards yourself. 4 4 Page no. 515 JC-PHY-A-042.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A042 - Remove/Reinstall Generator Covers b. Lower the cover to the floor so the holes (5) in the bottom end of the cover pass past the rods (6) on each side. 6 5 c. Disconnect the ground wire (7) at the Generator end to avoid risk of creating a short circuit. 7 d. Fully remove the cover and store it in a safe place. 6. For the left and right covers, do the following: a. Remove the two bolts (8) that secure the top of the cover (7 mm open ended wrench)and pull it towards yourself. 8 8 Chapter 6 Page no. 516 JC-PHY-A-042.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A042 - Remove/Reinstall Generator Covers b. Lift the cover away from the floor so the holes (9) in the bottom end of the cover pass past the rods (10) on each side. 10 9 c. Disconnect the ground wire (11) at the Generator end to avoid risk of creating a short circuit. 11 d. Fully remove the cover and store it in a safe place. Page no. 517 JC-PHY-A-042.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A042 - Remove/Reinstall Generator Covers 6-2 Install Generator Covers The left and right (thinner covers) must be installed before you install the front and back covers. ! Notice: Take care when replacing the Generator Cabinet covers, especially after connecting water pipes to the Conditioner. Check that the covers do not compress the pipes and cause a blockage. 1. Remove all power from the Senographe. 2. For the left and right covers, do the following: a. Connect the cover ground wire (1) to the Generator cabinet. 1 b. Lower the cover towards the floor so the holes (2) in the bottom end of the cover pass on to the rods (3) on each side. 3 2 c. Slide the lip of the cover upwards so it passes side of the Generator cabinet. Fully push the cover on to the top of the Generator cabinet. Then secure the cover to the Generator cabinet with the Chapter 6 Page no. 518 JC-PHY-A-042.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A042 - Remove/Reinstall Generator Covers two bolts (4) (7 mm open ended wrench). 4 4 3. For the front and back covers, do the following: a. Connect the cover ground wire (5) to the Generator cabinet. 5 b. Raise the cover from the floor so the holes (6) in the bottom end of the cover pass on to the rods (7) on each side. 7 6 c. Slide the lip of the cover upwards so it passes side of the Generator cabinet. Fully push the cover on to the top of the Generator cabinet. Then secure the cover to the Generator cabinet with the Page no. 519 JC-PHY-A-042.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A042 - Remove/Reinstall Generator Covers two bolts (8) (7 mm open ended wrench). 8 8 4. Connect the earth cable (9) to the top cover and place the top cover on the Generator cabinet. 9 5. Use the four allen screws (10) to secure the Generator top cover (5.5 mm allen wrench). 10 10 10 Chapter 6 10 Page no. 520 JC-PHY-A-042.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A042 - Remove/Reinstall Generator Covers 6. Attach the four plastic blanking disks (11) in each corner of the Generator top cover to hide the allen screws that secure the Generator top cover. 11 11 11 11 7. Ensure that the Generator covers have been correctly fastened and all blanking disks are correctly installed. Page no. 521 JC-PHY-A-042.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A042 - Remove/Reinstall Generator Covers This page is blank. Chapter 6 Page no. 522 JC-PHY-A-042.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A044 - Remove/Reinstall Gantry Covers Job Card PHY A044 - Remove/Reinstall Gantry Covers 1 Chapter 6 SUPPLIES None 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 20 minutes to remove covers, and 30 minutes to reinstall covers 4 SAFETY PRECAUTIONS WARNING Before beginning work, shut down the equipment and switch off the Generator hospital supply circuit breaker. Lock it in the off position or mark it clearly with a warning sign to prevent others from applying power. Never lay a cover down with the painted side on a hard surface. 5 PREREQUISITES None 6 OVERVIEW For an overview of the covers, refer to Gantry Covers on page 189. List of covers: • Column Covers (section 7) - Cable Exit Cover - Top Column Cover (Left and right) - Bottom Column Covers (Rear and front) - Front covers (Left and right) • Compression and Arm Covers (section 8) - Compression Carriage Cover - Compression Arm Covers (Left and right) • Tube Head Covers (Left and right) (section 9) • Detector Covers (Upper and lower covers) (section 10) There are different types of covers • Pilot covers • Series covers which are divided into two kinds: - Flexible covers - Rigid covers The procedure is valid for all covers except where specified. Page no. 523 JC-PHY-A-044.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A044 - Remove/Reinstall Gantry Covers 7 COLUMN COVERS ! Notice: When reinstalling these covers, ensure that the covers do not pinch the footswitch cables. Also, ensure that the footswitch cables are secured with cable ties to prevent any possibility of them being pulled from their connectors. 7-1 Cable Exit Cover 3 1. Locate the cable exit cover (1) on the right column cover. 2. Release and remove the two screws (2) securing the cable exit cover (large screwdriver). 3. Pull the cover forward to slide the lip (3) out of the groove and remove the cable exit cover. 7-2 1 2 Top Column Covers Top cover left 1. Power off the Gantry. 2. Unscrew completely the rear locking screws (1) from each column half-cover. 3. Unscrew completely the side locking screws (2) from each column half-cover. 4. Lift and slide the complete half-cover towards you to remove it. CAUTION Be careful not to pinch or damage cables. Note: On pilot systems the right cover must be removed before the left cover. On production systems the left cover must be removed before the right cover. 1 2 Perform the procedure in reverse order for reinstallation. Ensure that the Column covers have been correctly fastened and all blanking disks are correctly installed. CAUTION 1. When fastening the locking screws, turn the screw until moderate pressure is felt. Never apply excessive torque; the locking screw or the cover can be permanently damaged. 2. Whenever the Column Top covers are removed, both stop motion buttons must be tested after reinstallation. Press the stop motion button and check that a HALT error is triggered. Chapter 6 Page no. 524 JC-PHY-A-044.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A044 - Remove/Reinstall Gantry Covers 7-3 Front Covers 1 1. Switch the Gantry power off. 2. For each half front cover (2), do the following: - Release the securing screw (1). - Lift and slide the half cover towards you to remove it. Front right cover shown here CAUTION Be careful not to pinch or damage cables. 2 3. Remove the front covers. Perform the procedure in reverse order for reinstallation. Ensure that the Front covers have been correctly fastened and all blanking disks are correctly installed. 7-4 Bottom Column Covers 1 1. Remove the top column covers (section 7-2) and front covers (section 7-3). 2. Release and remove the two securing screws (1) (6 mm allen wrench). 3. Remove the front bottom cover (2). 2 4. Release and remove the two securing screws (3) (6 mm allen wrench). 4 5. Remove the back bottom cover (4). Page no. 525 JC-PHY-A-044.fm 3 Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A044 - Remove/Reinstall Gantry Covers 8 COMPRESSION AND ARM COVERS 8-1 Compression Carriage Covers 1. 2. 3. 4. 5. Remove the Compression Paddle. Set the arm to a convenient height. Turn the Gantry power off. Using a flat blade, remove the plastic caps. Release the screws (1, 2) securing the Compression Carriage cover. 6. Remove the lower and upper parts of the Compression Carriage cover (3). Perform the procedure in reverse order for reinstallation. Ensure that the Compression Carriage covers have been correctly fastened and all blanking disks are correctly installed. 8-2 Arm Covers and Handle 8-2-1 Arm Cover Removal 1. Remove the Compression Carriage covers - see section 8-1. 2 1 3 1 2. Release and remove the handle securing screw (1) (8 mm allen wrench). 2 3. Remove the handle (2). Note: To remount the handle, when the handle is back in place, you must push the foam near the ends (3) in place until it exactly matches the arm covers. 3 Chapter 6 Page no. 526 JC-PHY-A-044.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A044 - Remove/Reinstall Gantry Covers 4. Remove the spring clip (4) which secures the small pulley (5) to the shaft. 5. Remove the pulley. CAUTION 6. 7. 8. 9. When removing the pulley take great care not to lose the anti-rotation key (6) which locks it to the shaft. Disengage and remove the belt (7). Disconnect the Paddle Board cable (W304) (8) and the ground cable (9). Cut the two cable ties (10) securing the ground cable. Release and remove the four screws (11) (two on each side - 4 mm allen wrench) which secure the paddle holder. Remove the paddle holder. 4 5 6 11 8 8 10 9 10. Release the two halves of the arm cover by removing one of the lower screws (12) (large screwdriver). 11. Carefully remove the arm covers. When removing the arm covers pay attention not to damage the Compression board which is connected to each of the arm covers by a ribbon cable. Before you fully remove each of the arm covers, disconnect the ribbon cable that connects to the control buttons on the arm covers. • For flexible covers: Release and remove the side securing screw (13) on each side (3 mm allen wrench). Page no. 527 JC-PHY-A-044.fm 12 13 Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A044 - Remove/Reinstall Gantry Covers 8-2-2 Arm Cover Reinstallation • To reinstall the arm covers, carry out the above operations in reverse order. Note: During reassembly of flexible covers, be careful not to apply excessive force to the side securing screws (11), to avoid breaking the support. CAUTION • During reassembly of the small pulley (5), double check that its anti-rotation key (6) and securing clip (4) are correctly set in place. If the key is absent or the belt slides from its position, manual compression functions and braking are not available. If there is a motorized compression failure patient injury is possible. After installing the Arm covers, always carry out the procedures described in Job Card ELE A017 Manual Compression Check and Calibration on page 583. Chapter 6 Page no. 528 JC-PHY-A-044.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A044 - Remove/Reinstall Gantry Covers 9 TUBE HEAD COVERS WARNING • • Be careful when touching the Tube Head, as its temperature can be up to 80°C (about 180 °F) The two tube head covers (left and right) are held together 3 2 by four small tapped bars (positioned at references 2-5). Four screws in each cover hold the cover to these bars. A fifth screw (1) secures the cover to the tube head chassis. The GE logo hides the screw number 4. Plastic caps hide the other screws. To remove the covers, proceed as follows: 1. 2. 3. 4. 5. Remove the face shield. Lower the arm to a convenient height. Switch the Gantry power off. Remove the GE logo (velcro). When the logo has been removed, use the end of an allen wrench to extract the retaining washer. 6. Use a flat blade to remove the plastic caps which cover the securing screws (slim flat blade). 4 1 5 6 Note: Plastic caps are not present on pilot system covers. 1 7. Remove the two securing screws (1) at the rear of the tube (2.5 mm allen wrench). 8. Remove one of the securing screws (5) near the face shield attachment. These screws are not present on pilot systems, since pilot systems use a hook to hold the covers together at this location of the Tube Head. 9. Hold the left and right covers together, and release the covers from each other. Do this by removing one screw in each of the three pairs of securing screws (2, 3, 4) at the top of the tube (2.5 mm allen wrench). CAUTION The air grille (6) is in two parts, held between the covers. If the grille is not supported when the covers are separated, it will fall. 10. Remove the left tube head cover and remove the two parts of the grille, then remove the right cover. CAUTION When removing the head covers pay attention not to damage the Tilt board which is connected to each of the head covers by a ribbon cable. Before you fully remove each of the head covers, disconnect the ribbon cable that connects to the control buttons on the head covers. Page no. 529 JC-PHY-A-044.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A044 - Remove/Reinstall Gantry Covers • • 10 Reverse the procedure to replace the covers. Ensure that the Tube Head covers have been correctly fastened and all blanking disks are correctly installed. DETECTOR COVERS 10-1 Removing pilot systems detector covers 1. 2. 3. 4. Set the arm to a convenient height. Turn the Gantry power OFF. Remove the Bucky. Release and remove the securing screws (1) (4 mm allen wrench) while holding the lower cover (2). 1 3 2 1 5. Remove the Detector lower cover (2). 6. Remove the Detector upper cover (3). 10-2 Replacing pilot systems detector covers 1. Replace the Detector upper cover (1). 1 Chapter 6 Page no. 530 JC-PHY-A-044.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A044 - Remove/Reinstall Gantry Covers 2. Replace the Detector lower cover (2). 2 3. Reattach the securing screws (3) (4 mm allen wrench) while holding the lower cover (2). Make sure that both screws which secure the lower cover are tightened with equal pressure. 3 2 4. Replace the Bucky. 5. Switch the Gantry power ON. 10-3 Removing production systems detector covers 1. Set the arm to a convenient height. 2. Switch the Gantry power OFF. 3. Remove the Bucky. 4. Release and remove the screws (1) securing the latch hooks (4 mm allen wrench). 3 4 1 5 2 1 Page no. 531 JC-PHY-A-044.fm Chapter 6 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A044 - Remove/Reinstall Gantry Covers 5. Remove the latch hooks (4). 6. Remove the cover securing screws (5) (not visible when the latch hooks are mounted) while holding the lower cover (2). 7. Remove the Detector lower cover (2). 8. Remove the Detector upper cover (3). 10-4 Replacing production systems detector covers 1. Replace the Detector upper cover (1). 1 2. Replace the Detector lower cover (2). 3 4 2 3. Reattach the cover securing screws (3) while holding the lower cover (2). 4. Reattach the latch hooks (4). 5. Reattach the screws (5) (4 mm allen wrench) securing the latch hook. Make sure that both screws Chapter 6 Page no. 532 JC-PHY-A-044.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A044 - Remove/Reinstall Gantry Covers which secure the latch hook are tightened with equal pressure. 5 3 6. Replace the Bucky. 7. Switch the Gantry power ON. 8. Ensure that the Detector cover has been correctly fastened. Page no. 533 JC-PHY-A-044.fm Chapter 6 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PHY A044 - Remove/Reinstall Gantry Covers This page is blank. Chapter 6 Page no. 534 JC-PHY-A-044.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Electrical Installation CHAPTER 7 ELECTRICAL INSTALLATION This chapter contains information for the electrical installation and checking of the Senographe system. Page no. 535 Chap-Electrical Install.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Electrical Installation This page is blank. Chapter 7 Page no. 536 Chap-Electrical Install.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Scenario ELE A001 - Electrical Installation Scenario ELE A001 - Electrical Installation 1 Chapter 7 CONTEXT This Scenario provides information for the electrical phase of a first installation of Senographe equipment on the customer site. The installation is split into two phases: • Physical installation: positioning and cabling the various sub-systems without applying power. Refer to chapter 6 Physical Installation on page 375. • Electrical installation: powering on the system, configuration, and verification, up to start-up with the customer. This is treated in this scenario. 2 STEERING GUIDE Refer to the following Steering Guide for an outline of the recommended sequence of electrical installation, followed by checks and calibration. Electrical Installation Steering Guide: Step Action Job Card 1 Check the review workstations in use for first & second review vs IHE Mammography Image Profile compliance. Make decision with customer to upgrade ADS SW See OM Addendum (5427687-1-199) 2 Contact your local OLC to schedule Insite Checkout; request modem address and software keys Contact printer supplier representative Comments Done Preparation Preliminary Power-up 3 Check supply voltages Job Card ELE A005 - Check Supply Voltages on page 541 4 First System Power-up Job Card ELE A006 - First System Power-On on page 543 5 Carry out line resistance check Job Card ELE A007 - Line Resistance Measurement on page 547 Optional 21-inch 3 MP Monitor configuration 6 If the Senographe system has the 21inch 3 MP Monitor option, configure the monitor resolution Job Card ELE A008 - Configuring the 21-inch 3MP Monitor on page 549 Only perform if the system has the 21inch 3 MP monitor Install Image Receptor 7 Unpack/Install Image Receptor, add coolant, check for leaks and install detector covers Job Card ELE A060 - Image Receptor Installation on page 781 Configuration Page no. 537 SC-ELE-A-001.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Scenario ELE A001 - Electrical Installation Step Action 8 Configure Generator 9 Set Gantry travel limits Job Card Comments Done Job Card ELE A009 - Generator Configuration on page 561 Job Card ELE A010 - Set Lift Travel Limits on page 565 Checks 10 Generator Functional Checks Job Card ELE A012 - X-ray Parameter Check on page 571 11 Refit Generator covers Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513 12 Gantry Functional Checks Job Card ELE A015 - Gantry Functional Checks on page 579 13 Collimation Checks 14 If you had remove the Gantry Covers to get the Gantry into the room then refit Gantry Covers Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. 15 Manual Compression Check Job Card ELE A017 - Manual Compression Check and Calibration on page 583 Job Card ELE A028 - Collimation Checks on page 679 Configuration 16 AWS configuration Job Card ELE A013 - AWS Configuration on page 573 17 Network connection and configuration Job Card ELE A021 - Networking Connection and Configuration on page 625 18 Optionally change the internal IP address of the Senographe system Job Card ELE A050 - Changing Senographe Internal IP Addresses on page 757 19 Declare Network Hosts Job Card ELE A022 - Declare Network Hosts on page 663 20 Declare Worklist Hosts Job Card ELE A023 - Declare Worklist Hosts on page 671 21 Declare Performed Procedure Step Hosts Job Card ELE A024 - Declare Performed Procedure Step Hosts on page 675 22 Declare Printers Job Card ELE A020 - Declare and Set Printers (Filming Devices) on page 585 23 Change the AOP configuration Job Card ELE A031 - AOP Configuration on page 693 24 Install Embedded Publications Job Card ELE A044 - Install User Publications on page 755 Optional. Only required if the hospital network is the same as the Senographe internal network Optional configuration Chapter 7 Page no. 538 SC-ELE-A-001.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Scenario ELE A001 - Electrical Installation Step Action 25 Repeat and Reject Analysis Configuration 26 Installation of CAD Option onAWS Job Card Comments Done Job Card ELE A067 - Repeat and Reject Analysis Configuration on page 791 Job Card ELE A071 - Installation of CAD option on AWS on page 793 Hardware options 27 Install Required options Mass Archiver - LaserCam - Review Workstation 28 Install Bar Code Scanner if present Refer to supplied manuals Job Card ELE A042 - Bar Code Scanner (Option) on page 715 Refit covers 29 Refit Control Station Covers Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503 Image Quality Checks 30 If Stereo or 2D Biopsy Optical Localizer option exists, calibrate the LCD Monitor 31 Flat Field Check 32 Image Acquisition & ACR Score 33 Acquisition in AOP mode Job Card ELE A043 - AWS Monitor Calibration on page 729 Job Card ELE A032 – IQ Tools Flat Field Test on page 699 Job Card ELE A037 - Image Acquisition and ACR Score on page 705 Job Card ELE A038 - AOP Mode and SNR Check on page 707 Detector Dose check (Germany only) 34 Compliance with Germany for Detector Dose Job Card ELE A039 - Compliance with Germany for Detector Dose on page 711 Only in Germany Stereotaxy installation and configuration 35 If Stereotaxy Option is present Refer to Stereotaxy SM (2390552) Completion 36 Complete AWS System configuration form Form LBK A001 - System Configuration Form on page 797 37 Backup configuration information Job Card ELE A052 - Back-up/Restore Procedure on page 771 38 Back-up/Restore procedure - Manual record sheets Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets on page 801 39 Clean up room and complete paperwork Page no. 539 SC-ELE-A-001.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Scenario ELE A001 - Electrical Installation This page is blank. Chapter 7 Page no. 540 SC-ELE-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A005 - Check Supply Voltages Job Card ELE A005 - Check Supply Voltages 1 Chapter 7 SUPPLIES None 2 TOOLS Multimeter (Fluke 87) 3 SAFETY PRECAUTIONS None 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 40 minutes 5 PREREQUISITES The procedures described in Job Card PHY A016 - AC Connection must have been completed correctly. 6 FIRST POWER-ON CHECK You must detect incorrect mains supply configuration - before it is too late! 6-1 Check the Keep-Alive Supply Voltage 1. Check that generator Mains Supply Switch 200-S1 is open (i.e. in the "0" position). 2. Check that the Mains Distribution Rack circuit breaker is open (i.e. in the ”0” position). 3. Close the main hospital supply circuit breaker. 4. Connect the multimeter (set to 20 VDC scale) to the Mains Distribution Board 200-PL1 between test points PT15 (+VE) and PT12 (0VE). See illustration. 5. Close generator Mains Supply Switch 200-S1 (i.e., turn it to the ”1” position) and read the multimeter immediately. It must read +8 ±2 VDC. POWER BOARD 200-PL1 R4 R1 TR2 X1 0VE PT12 PT14 PT15 +VE - VE + VE CAUTION If the voltmeter reading is outside this range, turn mains source off immediately. Then check the configuration of voltage selection board IN2 on the Generator Mains Distribution Board 200-PL1 (see Job Card PHY A016 - AC Connection). 6. Move the multimeter from PT15 (+VE) to PT14 (-VE). The multimeter must read -8V ± 2 VDC. 7. Connect the multimeter (set to 500 VAC scale) to the Generator Mains Power Board 200-PL1 between terminals 1 (0 V) and 4 (220 V). 8. Turn on the X-ray Console and read the multimeter immediately. It must read 220 ± 20 VAC. Page no. 541 JC-ELE-A-005.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A005 - Check Supply Voltages CAUTION If the voltmeter reading is outside this range, open generator Mains Supply Switch 200-S1 immediately (turn it to the "0” position). Then check mains voltage selection wire SEL on Generator Mains Distribution Board 200-PL1 (see Job Card PHY A016 - AC Connection). 7 CHECK GENERATOR AND GANTRY DC SUPPLY VOLTAGES 7-1 Check Generator DC Supply Voltages 1. Power the Generator on. 2. On the Generator CPU Board 400-PL3, measure the DC voltage between TP110 and TP111 (GND). It must be in the range +5.1±0.05 V. If necessary, adjust the voltage. WARNING The adjustment is made using the potentiometer located on the low voltage power supply unit (on the rear of the board mounting plate). To avoid any risk of electric shock, do not touch any of the other components on the supply (later models are protected by a transparent cover). 3. On the Generator Interface Board 400-PL2, measure the DC voltage (+12 V nominal) between PT3 and PT4. The voltage must be in the range +11.5 VDC to +12.5 VDC. 4. On the Generator Interface Board 400-PL2, measure the DC voltage (-12 V nominal) between PT5 and PT4. The voltage must be in the range -11.5 VDC to -12.5 VDC. Note: Voltages measured in steps 2 and 3 above depend on the +5 V adjustment mentioned in step 1. 5. If the potentiometer located on the low voltage power supply unit (step 1) has been adjusted, apply a suitable locking compound to prevent further movement. 8 CHECK MAINS DISTRIBUTION RACK INPUT If the above check for Generator voltages was correct, this confirms that the correct voltage has been selected for the Generator input voltage. Before switching power to the Mains Distribution Rack, check that the same voltage has been selected for the Mains Distribution Rack transformer input tap. Chapter 7 Page no. 542 JC-ELE-A-005.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A006 - First System Power-On Job Card ELE A006 - First System Power-On 1 Chapter 7 SUPPLIES None 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 40 minutes 4 SAFETY PRECAUTIONS None 5 • • 6 PREREQUISITES The installed components (AWS, IDS, Conditioner, etc.) must be in a safe state, ready to receive power, and all of their power switches must be set to on. The instructions in Job Card ELE A005 - Check Supply Voltages must have been carried out to ensure that the Generator and Mains Distribution Rack power supplies are correctly configured. FIRST POWER ON After installation of the system, it must be powered up before installing options or configuring the system. CAUTION When you are ready to apply power to the Senographe system for the first time, carry out the following steps: Note: If any problem is encountered during the first power up, refer to the checklists for power up/down given in Job Card CHK A001 - Boot/Init and Shutdown on page 1729. 1. Set the circuit breaker connecting the hospital supply to the Senographe system to on. 2. Set the two circuit breakers in the Generator Cabinet (one in the Generator Rack, the other in the Main Distribution Rack) to on. 3. To power up the system, press the power switch I on the X-ray Console. Power is applied to the whole system (Generator, Gantry, Control Station, Digital Detector, etc.). Green power indicators are lit on the Generator Cabinet, the Control Station, and the LCD Monitor. Page no. 543 JC-ELE-A-006.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A006 - First System Power-On 4. A series of system initialization messages appears on the screen, then the Login: prompt appears. Login as the sdc user as follows: a. At the Login: prompt enter: sdc b. At the Password: prompt, press the key. The Browser window appears after a short delay with the AWS login screen. Note: As the Detector is not yet connected, some error messages related to acquisition capability appear on the screen. If the screen is still blank after about 30 seconds, check that the monitor is switched on (the green LED must be lit) and connected. Check that the keyboard is also connected. 5. At the AWS login screen, select clinical from the Username drop-down field, type clinical in the Password field and click the OK button. The Browser appears. 6. Check that the ADS Computer can communicate with the IDC, as follows: a. Check that the IDC is powered up (power LED on the front of the IDC is lit on and the fans are working). If the IDC is not powered up ensure that the power switch on the front of the IDC is set to on (I). Power switch must be set to I Power LED b. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. c. Attempt to ping the IDC, by entering: ping idc If the IDC responds to the ping command then communications are fine. If the IDC does not respond to the ping command then check all IDC cable connections, Especially ADS-IDC Ethernet communication. Check that both ADS and IDC Ethernet cables are correctly plugged into the switch. When the system has been successfully powered up, it must be powered down ready for the next steps in the installation process. Follow the normal shutdown procedure described on the following page. Chapter 7 Page no. 544 JC-ELE-A-006.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A006 - First System Power-On 7 • • • POWERING DOWN THE SYSTEM Normal Shutdown Procedure: Switch power off at the AWS Monitor by clicking the System Shutdown button on the Browser window. Wait for complete system and UPS shut down (about 2 minutes); check that no LEDs remain lit on the UPS before continuing. To power down the Gantry and Generator system only, press the switch STOP on the X-ray Console. Never switch off at the UPS directly except in emergency (risk of data loss). Page no. 545 JC-ELE-A-006.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A006 - First System Power-On This page is blank. Chapter 7 Page no. 546 JC-ELE-A-006.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A007 - Line Resistance Measurement Job Card ELE A007 - Line Resistance Measurement 1 Chapter 7 SUPPLIES None 2 TOOLS Multimeter (Fluke 87) 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 40 minutes 4 SAFETY PROCEDURES During the procedures in this Job Card, you are in close proximity to circuits operating at line voltage take appropriate precautions. 5 PREREQUISITES You must follow the chronological order given in the Installation Job Card Installation Steering. Note: Make sure that the X-ray Console is connected to the Generator. 6 PROCEDURE If the resistance at the line input to the Senographe generator is too high, there will be a significant voltage drop when the generator draws maximum power. This procedure checks that the resistance is within acceptable limits. 6-1 Preparation 1. Switch off the system; set the Generator power switch 200-S1 to the 0 position. 2. Disconnect voltage selection wire SEL from its lug on the Mains Distribution Board 200-PL1; reconnect it to the 0 V lug. ! Notice: The 0 V position of the SEL wire is reserved exclusively for this line resistance measurement. The Senographe cannot function normally when the SEL wire is in this position. Do not attempt to switch on the Senographe at this point - follow the instructions below. 3. Connect the multimeter to the input end of the power switch 200-S1; Note and write down the observed value of the open-circuit line voltage V1: V1 =...................................... 6-2 Procedure 1. Turn on the AC supply: set the generator switch 200-S1 to the 1 position. Note: Read the next step completely before performing it. You only 3 seconds have to read the voltmeter; if you miss the reading you must wait about 15 minutes to repeat it. Page no. 547 JC-ELE-A-007.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A007 - Line Resistance Measurement 2. While looking at the multimeter, press the power-on switch on the Supply Command Board 200-PL2. During a period of 3 seconds, a resistive load (power resistors R1 and R4 on the Supply Command Board 200-PL2) is connected across the line input, causing a drop in the voltage reading on the multimeter. Note and write down this closed circuit voltage: V2 =.................................... Note: After this 3 second period the red LED DE3 on the Supply Command Board 200-PL2 illuminates. This indicates that heating of the resistive load prevents an immediate repeat reading. After about 15 minutes, the LED goes out, the reading can then be repeated if necessary. 3. Calculate line resistance RL according to the formula: RL = [(V1 - V2) / V2] RINT where RINT, the internal resistive load, depends on the nominal AC supply voltage V: RINT (Ω) Voltage (V) 200 11 208 11 220 11 240 11 4. Turn off the Senographe: set the generator power switch to the 0 position and switch off AC power. 5. Disconnect the line voltage selection wire SEL from the 0 V lug on the Mains Distribution Board 200PL1. Reconnect the line voltage selection wire to the lug corresponding to the nominal (not measured) AC line voltage. Tighten the lug nuts to a torque setting of 4 Nm. Check that the calculated line resistance RL does not exceed the maximum value given in Table 1 for the nominal AC supply voltage. If the calculated value exceeds the maximum value given in Table 1, consult with the hospital electrical department and your OLC. The problem must be resolved before the Senographe system is put into service. TABLE 1 - MAXIMUM PERMISSIBLE LINE RESISTANCE Chapter 7 Nominal AC voltage Maximum Line Resistance 240 V 0.40 220 V 0.34 208 V 0.30 200 V 0.28 Page no. 548 JC-ELE-A-007.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A008 - Configuring the 21-inch 3MP Monitor Job Card ELE A008 - Configuring the 21-inch 3MP Monitor 1 Chapter 7 SUPPLIES None 2 • • TOOLS 3MP Test Pattern CD-ROM (P/N 5175614) A calibrated Luminance Meter that permits measuring the luminance of the monitor in contact (Direct) mode as illustrated below. ATTENTION: 1. When putting the Luminance Meter into contact with the monitor screen, do not apply excessive pressure. Remove canon and place foam ring 2. When measuring the luminance value of different parts of the screen, ensure that you apply the same level of pressure on each different part of the screen. Luminance Meter • If the Siemens Serial Spot Meter (P/N 2319223) is used, it must be used with the foam ring attached, and must be configured in Direct mode. Foam Ring Direct mode selected Away/Direct mode button selector • 3 The Away/Direct button toggles between away and direct modes. To select the Direct mode, keep pressing the Away/Direct button until D is displayed on the lower left corner of the Spot Meter screen. REQUIRED EFFORT Personnel: 1 Field Engineer Time: 40 minutes Page no. 549 JC-ELE-A-008.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A008 - Configuring the 21-inch 3MP Monitor 4 SAFETY PRECAUTIONS None 5 APPLICABILITY This Job Card is only applicable to Senographe systems running ADS 53.40 and above, which have optional the 21-inch 3 MP Monitor installed. The 21-inch 3 MP Monitor is only available for V3 and V4 Control Stations. 6 PREREQUISITES The 21-inch 3 MP Monitor has been physically connected during the physical installation phase of the Senographe system. Note: Ensure that the monitor DVI cable is connected to the left hand side DVI connector on the back of the ADS computer. 7 PROCEDURE 7-1 Resolution Configuration The steps you undertake depend on whether you have a V3 or V4 Control Station, as summarized in the following steering guide. V3 Control Stations (U20 - Xsun server) V4 Control Stations (Z400 - Xorg server) Nothing to do as Z400 uses Xorg server for the graphics management which auto-detects - see section 7-1-2, Resolution Configuration on V4 Control Stations on page 551. Perform kdmconfig to set monitor size and resolution - see section 7-1-1, Resolution Configuration on V3 Control Stations on page 550. Expand ADS GUI to Fill the Entire Monitor See section 7-1-3, Expanding the ADS GUI to Fill the Monitor (V3 and V4 Control Stations) on page 552. 7-1-1 Resolution Configuration on V3 Control Stations 1. Reboot the ADS Workstation to ensure that you are at the first Login: prompt. A series of system initialization messages appears on the screen, then the Login: prompt appears. 2. Login as the root user as follows: a. At the Login: prompt, enter: root b. At the Password: prompt, enter: operator A command prompt appears for the root user. 3. At command prompt, launch the Desktop Manager Configuration Tool, by entering: kdmconfig Chapter 7 Page no. 550 JC-ELE-A-008.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A008 - Configuring the 21-inch 3MP Monitor The Desktop Manager Configuration Tool appears. Within the Desktop Manager Configuration Tool you use the cursor keys to move up and down between the different options, and the space bar to select an option. The currently selected option contains an x within the brackets. 4. At the first kdmconfig page, leave the Xsun server option selected. Press the F2 key to continue. 5. At the kdmconfig - View and Edit Window System Configuration page that appears, use the cursor keys to move to the Change Video Device/Monitor option, and press the space bar to select that option. Press the F2 key to continue. 6. At the kdmconfig - Video Device Selection page that appears, use the cursor keys to move to the XF86-NV Nvidia Corporation Quadro FX560 option, and press the space bar to select that option. Press the F2 key to continue. 7. At the kdmconfig - Monitor Type Selection page that appears, use the cursor keys to move to the MultiFrequency 95kHz (up to 1600x1200 @ 75Hz) option, and press the space bar to select that option. Press the F2 key to continue. 8. At the kdmconfig - Screen Size Selection page that appears, use the cursor keys to move to the 21-inch (53cm) option, and press the space bar to select that option. Press the F2 key to continue. 9. At the kdmconfig - Resolution/Colors Selection page that appears, use the cursor keys to move to the 2048x1536 256 colors @ *** option, and press the space bar to select that option. Press the F2 key to continue. 10. At the kdmconfig - View and Edit Window System Configuration page that appears, leave the No changes needed - Test/Save and Exit option selected. Press the F2 key to continue. 11. At the kdmconfig - Window System Configuration Test page that appears, press the F2 key to run the screen test. 12. From the test screen that appears, click on: • Yes, if screen is displayed correctly (buttons and text are readable). • No, if screen is not displayed correctly and redo steps 5 to 11. Once the monitor test is successful, and you click Yes you are automatically returned to the command line. 13. Exit as root user, by entering: exit 14. Go to section 7-1-3, Expanding the ADS GUI to Fill the Monitor (V3 and V4 Control Stations) on page 552. 7-1-2 Resolution Configuration on V4 Control Stations The kdmconfig utility will have been peformed during the ADS configuration with the choice of Xorg server for the graphics management. Unlike the Xsun server used with the V1/V2/V3 Control Stations, the Xorg server auto-detects the graphics card within the Z400 Workstation and the monitor connnected to the Z400 Workstation. Therefore, no additional kdmconfig steps are necessary for the V4 Control Station. Simply proceed to section 7-1-3, Expanding the ADS GUI to Fill the Monitor (V3 and V4 Control Stations) on page 552. Page no. 551 JC-ELE-A-008.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A008 - Configuring the 21-inch 3MP Monitor 7-1-3 Expanding the ADS GUI to Fill the Monitor (V3 and V4 Control Stations) 1. At the Login: prompt, login as sdc user to launch the Browser. 2. At the Browser login prompt, login as clinical user (password usually clinical). Note: At this stage the Browser will appear in the middle of the screen at a lower resolution than the 21-inch 3MP Monitor, with a black border around it. This is normal, and the following steps will configure the ADS computer to use the full resolution of the 21-inch 3MP Monitor. 3. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 4. Change to the ~sdc/senovision/scripts directory, by entering: cd ~sdc/senovision/scripts 5. Set the 3 MP Monitor option, by entering: SetMonitorConfig.sh 3MP The SetMonitorConfig.sh script runs, as follows:
#, where
www.patamerica.com PAT America, Inc. LOAD MOMENT INDICATOR DS 350G/GW LMI for Hydraulic Boom Cranes SERVICE MANUAL P/
# are the last seven digits of the CAD Unit serial number found on the back of the computer). It may be necessary to insert the IP Address in the Host name field. 5. Click the SUBMIT button. A message appears indicating that a ping to the CAD Unit is successful. Note: A message indicating that the DICOM Echo failed is also displayed. At this point, this is not an indication of a problem. If the declaration was not successful, check the network connections and try again. 6. After successful declaration, you can connect to the newly declared CAD Unit by selecting its radio button and clicking the CONNECT TO button. 7. The newly declared CAD Unit must now be configured. Follow the instructions given in the CAD Unit Service Manual to configure the newly declared CAD Unit. Chapter 7 Page no. 794 JC-ELE-A-071.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN System Identification and Follow-up CHAPTER 8 SYSTEM IDENTIFICATION AND FOLLOW-UP This chapter contains a form to be completed at installation time. The form must be updated as required to provide a record of the system history, including hardware and software changes. Page no. 795 Chap-System History.fm Chapter 8 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN System Identification and Follow-up This page is blank. Chapter 8 Page no. 796 Chap-System History.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Form LBK A001 - System Configuration Form Form LBK A001 - System Configuration Form 1 Chapter 8 INTRODUCTION Complete a copy of this form at the end of installation. Leave it attached to the site Log Book; upgrade it for each configuration change (new option, new software release, etc.). MACHINE TYPE: SERIAL NUMBER: HOSTNAME (see Note 1): IP ADDRESS (see Note 1): NETMASK (see Note 2): SDC PASSWORD: HOSPITAL NAME: USER INTERFACE LANGUAGE: APPLICATION SUPPORT TELEPHONE: MISCELLANEOUS: Note 1: To obtain the hostname and the IP address, open the Service desktop and press the Home icon. Alternatively, open a command window and enter: more /etc/hosts ; the line ending by loghost tells you the IP adress and hostname. Note 2: To obtain the netmask value (if it exists): open a Command window and enter: more /etc/netmasks If you get the answer: No such file, there is no netmask installed. Otherwise look at the end of the displayed file. Example: 192.1.1.0 255.255.255.0 (network address followed by netmask value). SOFTWARE INITIAL REVISION: SOFTWARE UPGRADE REVISION: SOFTWARE PROTECTION KEY: CD-R PROTECTION KEY: Page no. 797 FRM-LBK-A-001.fm Chapter 8 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Form LBK A001 - System Configuration Form NETWORK HOST NUMBER 1: Hostname: IP address: Host label: Port Number: Protocol: Comments: A.E. Title: NETWORK HOST NUMBER 2 Hostname: IP address: Host label: Port Number: Protocol: Comments: A.E. Title: NETWORK HOST NUMBER 3 Hostname: IP address: Host label: Port Number: Protocol: Comments: A.E. Title: NETWORK HOST NUMBER 4 Hostname: IP address: Host label: Port Number: Protocol: Comments: A.E. Title: NETWORK HOST NUMBER 5 Hostname: IP address: Host label: Port Number: Protocol: Comments: A.E. Title: NETWORK HOST NUMBER 6 Hostname: IP address: Host label: Port Number: Protocol: Comments: A.E. Title: NETWORK HOST NUMBER 7 Hostname: IP address: Host label: Port Number: Protocol: Comments: A.E. Title: NETWORK HOST NUMBER 8 Hostname: IP address: Host label: Port Number: Protocol: Comments: A.E. Title: Chapter 8 Page no. 798 FRM-LBK-A-001.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Form LBK A001 - System Configuration Form NETWORK or DICOM PRINTER NUMBER 1: Hostname: IP address: Protocol: Port Number: A.E. Title: Comments: NETWORK or DICOM PRINTER NUMBER 2 Hostname: IP address: Protocol: Port Number: A.E. Title: Comments: NETWORK or DICOM PRINTER NUMBER 3 Hostname: IP address: Protocol: Port Number: A.E. Title: Comments: NETWORK or DICOM PRINTER NUMBER 4 Hostname: IP address: Protocol: Port Number: A.E. Title: Comments: ROUTING TABLE: route add net: route add net: route add net: route add net: route add net: 1-1 AOP Configuration on Generator and AWS Computer Complete the following table after performing Job Card ELE A031 - AOP Configuration on page 693. AOP DOSE Mode (set on Generator) AOP STD Mode (set on Generator) AOP CNT Mode (set on Generator) AOP Config (set on ADS) Page no. 799 FRM-LBK-A-001.fm Chapter 8 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Form LBK A001 - System Configuration Form This page is blank. Chapter 8 Page no. 800 FRM-LBK-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets Chapter 8 1 MANUAL PARAMETER BACKUP It is recommended that backups of the AWS parameters are made using floppy disks or CD-Rs, as described in Job Card ELE A052 - Back-up/Restore Procedure. However, if backup to floppy or CD-R is not possible, it may be necessary to record AWS parameters manually. This is so that they can be restored later (e.g., after an upgrade procedure). The following pages provide information and space to note each of the following sets of parameters: 1. Site Information and General Configuration. 2. Filter Management. 3. Browser Preferences: Layout. Filter. Sort. 4. Medical Application Preferences: Auto Push. Auto Print. Annotations. Auto windowing. Quality Check. Auto Delete. Test Hosts. Names. Image Process. 5. Worklist Management. 6. Worklist Query Definitions. 7. Network Management. 8. Printer Management. 9. PPS Management. 10. Needle Data. 11. AOP Configuration 12. Network Routing Information Page no. 801 FRM-LBK-A-003.fm Chapter 8 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets 1-1 • Site Information and General Configuration From the browser, click the Tools Menu button and then click Service Desktop to launch the Service Desktop. Then click the Configuration button . Click Site to view and note Site information, then General to view and note the General Configuration. Site Information Copy the current settings into the table below. (note that a Valid Service Key must be installed to display all settings): Parameter Current setting Site Name: Site Address: Phone: Fax: Contact Person: Phone: Station Name: General configuration. Copy the current settings into the table below. Auto Delete: System clock Upper threshold: . . . . . . . yyyy-mm-dd . . . . . . . .hh:mm:ss QAP timeout . . . . . . . days Screen Blank Timeout . . . . . . . minutes Language: English ........ % of occupied disk Français Lower threshold: Español ........ % of occupied disk Deutsch Minimum Image Storage Time: . . . . . . . . hours Italiano Portugès Dutch Danish Swedish Norvegian Finish Edit Patient: On Off Chapter 8 Page no. 802 FRM-LBK-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets 1-2 • Filter Management From the Browser, click the Tools menu button , then click Filter management. For each filter name, click Update to view the settings, and copy them into one of the tables below. Copy this sheet if you need additional space. 1. Filter name: Circle the current value Note current value of the parameter Patient level: Patient Name Begins with/Contains/Is Patient ID Begins with Contains/Is Exam level: Exam description Begins with/Contains/Is Performing Physician Begins with/Contains/Is Referring physician Begins with/Contains/Is Exam modality Exam date MG/DX N/A Between/Before/After/On Exam time Series level: Series description Series Type Begins with/Contains/Is SCPT/RAW/PROCESSED/SR N/A Patient/Exam/Series N/A Application level: Apply this filter up to the selected level Page no. 803 FRM-LBK-A-003.fm Chapter 8 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets 2. Filter name: Circle the current value Note current value of the parameter Patient level: Patient Name Begins with/Contains/Is Patient ID Begins with/Contains/Is Exam level: Exam description Begins with/Contains/Is Performing Physician Begins with/Contains/Is Referring physician Begins with/Contains/Is Exam modality Exam date MG/DX N/A Between/Before/After/On Exam time Series level: Series description Series Type Begins with/Contains/Is SCPT/RAW/PROCESSED/SR N/A Patient/Exam/Series N/A Application level: Apply this filter up to the selected level Chapter 8 Page no. 804 FRM-LBK-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets 3. Filter name: Circle the current value Note current value of the parameter Patient level: Patient Name Begins with/Contains/Is Patient ID Begins with/Contains/Is Exam level: Exam description Begins with/Contains/Is Performing Physician Begins with/Contains/Is Referring physician Begins with/Contains/Is Exam modality Exam date MG/DX N/A Between/Before/After/On Exam time Series level: Series description Series Type Begins with/Contains/Is SCPT/RAW/PROCESSED/SR N/A Patient/Exam/Series N/A Application level: Apply this filter up to the selected level Page no. 805 FRM-LBK-A-003.fm Chapter 8 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets 1-3 • Browser Preferences From the Browser click the Tools menu button , then click Browser preferences. Select each set of preferences in turn: Layout; Filter; Sort. Layout: Record the current settings on the illustration. Mark each selected button clearly with a cross. Filter: Record the current filter names for local and remote lists. If none, write "None": Local lists. Current setting: . . . . . . . . . . . . . . . . . . . . Remote lists. Current setting: . . . . . . . . . . . . . . . . . . . . Sort: For each parameter, circle the currently selected option: Sort patients by: Name/Identifier/Last study date Sort exams by: Date/Identifier/Description/Performing Physician/Referring Physician Modality: MG/DX Sort series by: Type/Number Sort images by: Number/Old-new date/New-old date Split series: Yes/No With Initial Series: Yes/No Chapter 8 (active when Split series = Yes) Page no. 806 FRM-LBK-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets 1-4 • Medical Application Preferences From the Browser, click the Tools menu button , then click Medical application preferences. Select each set of preferences in turn: Auto Push; Auto Print; Annotations; Auto Windowing; Quality Check; Auto Delete; Names; Image Process. Auto Push Circle the current selection: Auto Push ON/OFF. If Auto Push is ON, use the table below to enter the names in the Remote Host window, and circle the selected push criterion for each host: Remote Host Name Criterion Raw/Proc/Both/None Raw/Proc/Both/None Raw/Proc/Both/None Raw/Proc/Both/None Raw/Proc/Both/None Auto Print Circle the current selection: Auto Print ON/OFF . If Auto Print is ON, enter DICOM printer information in the table below. For each named printer, note the name, the selected print mode and the selected number of copies. Click the Printer properties button to obtain the selected print parameters. Parameters shown in square brackets in the table (e.g., [Fit to film]) are default values which normally do not change. Copy this sheet if you need additional space. DICOM printer Name Criterion Print mode Criterion [Fit to film] Number of Copies Printer properties Format [standard] Media type Paper/Clear film/Blue film Destination Magazine/Processor Film orientation Magnification type Film size Portrait/Landscape [Cubic] [8 in by 10 in] or [10 in by 12 in] Note: The sizes visible depend on the printers declared: Page no. 807 FRM-LBK-A-003.fm Chapter 8 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets Annotations Record the annotation settings: place a cross in the box beside each option currently selected: Annotation level Selected annotations Printing annotations Patient information Acquisition date and time Full Hospital information Model 1 Partial X-ray parameters Model 2 None Anatomical information Model 3 Custom Processing Information Display parameters Measurements Auto Windowing Circle the current selection: Standard/High/Low/User. Quality Check Circle the current selection: Enable Repeat and Reject Analysis YES/NO. If Repeat and Reject Analysis is enabled, use the table below to record the Auto Push and Auto Print configuration. For each parameter, place a cross in the appropriate YES/NO box: Parameter YES NO Auto Push Repeated images Auto Push Rejected images Auto Print Repeated images Auto Print Rejected images If Repeat and Reject Analysis is not enabled, circle the current selection below: Default Image Quality Check OK/NOT OK. Auto Delete Circle the current selection: Auto Delete ON/OFF . If Auto Delete is ON, use the table below to record the auto delete profile: place a cross in the box beside each of the options currently selected: Chapter 8 Raw images sent Both images sent Processed images committed Processed images sent Raw images committed Both images committed Page no. 808 FRM-LBK-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets Names Use the table below to record the currently entered names: Operators Image Process Circle the current selection: Performing Physicians Referring Physicians Fine View: Enable/Disable Premium View: Enable/Disable Premium View Strength: Low, Medium, High PVi enabled/disabled (see steps below to determine whether enabled or disabled) PVi High enabled/disabled (see steps below to determine whether enabled or disabled) To check the current installation status of the PV Strength and PVi , use the following steps: 1. From behind the Browser, right click the background, and from the Root Menu that appears, select Service Tools > Command Window to launch a command window. A command window appears with an ADS prompt. 2. Check the current installation status of the PV Strength and PVi , by entering: setenv | grep PV The command returns the current installation status, similar to the following: PV_EXT = TRUE PV_IMP = TRUE PV_IMP_HIGH = TRUE Where - PV_EXT indicates whether the PV Strength feature is enabled (TRUE) or disabled (FALSE) (this is the same as Premimum View Enabled/Disabled within Medical Application Preferences) - PV_IMP indicates whether the PVi feature is enabled (TRUE) or disabled (FALSE) - PV_IMP_HIGH indicates whether the PVi replacing the PV HIGH Strength feature is enabled (TRUE) or disabled (FALSE) Page no. 809 FRM-LBK-A-003.fm Chapter 8 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets 1-5 • Worklist Management From the Browser, click the Tools menu button , then click Worklist management. For each Host name listed, click Update to view the parameter settings, and copy them into the table below. Copy this sheet if you need additional space: Parameter Entry Entry Host label Host name Application Entity Title Network address Port number Comments 1-6 • • • Worklist Query Definitions From the right side of the Browser, click the Worklist icon to open the Worklist window. From the Worklist window, click the Query button to open the Query Definitions window. Note down the settings of the Query Definitions window into the table below. Which system Date This system Today All systems in modality Tomorrow All systems From : ________________ To : ________________ Patient Name Patient ID Accession # Study ID Chapter 8 Page no. 810 FRM-LBK-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets 1-7 • Network Management From the Browser, click the Tools menu button , then click Network management. For each Host name listed, click Update to view the remote host parameter settings, and copy them into the table below. Where multiple choices are shown, circle the selected parameter. Copy this sheet if you need additional space Parameter Host 1 Host 2 Host 3 Patient/Study/No provider Patient/Study/No provider Patient/Study/No provider Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Host label Host name Application Entity Title Network address Network protocol Port number Query retrieve Storage commitment Application Entity Title Network address Port number Manage send Comments Page no. 811 FRM-LBK-A-003.fm Chapter 8 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets 1-8 • - Printer Management From the Browser, click the Tools menu button , then click Printer management. For each DICOM printer listed, click Update to view the printer parameter settings. Copy the labels, names, etc., into one of the illustrations below and mark all selected check boxes with a cross. Copy the illustration if you need additional space: Printer 1: DICOM printer parameters DICOM printer label : Hostname : Application Entity Title (AET) : Network address : Port number : Layouts : 8 in x 10 Slide formats : 35 mm 40 mm Pixel depth : Film size : W 10 12 H 14 in x 14 W H 10 in x 12 W H 14 in x 17 W H 10 in x 14 W H 24 cm x 24 W H 11 in x 14 W H 24 cm x 30 W H Printer pixel size (micron) : Configuration information : Density : Magnification type : Min Max Cubic Smoothing factor : Trim : Printer Memory Size : Save Chapter 8 No Mbytes Clear Done Page no. 812 FRM-LBK-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets - Printer 2: DICOM printer parameters DICOM printer label : Hostname : Application Entity Title (AET) : Network address : Port number : Layouts : 8 in x 10 Slide formats : 35 mm 40 mm Pixel depth : Film size : W 10 12 H 14 in x 14 W H 10 in x 12 W H 14 in x 17 W H 10 in x 14 W H 24 cm x 24 W H 11 in x 14 W H 24 cm x 30 W H Printer pixel size (micron) : Configuration information : Density : Magnification type : Min Max Cubic Smoothing factor : Trim : Printer Memory Size : Save No Mbytes Clear Page no. 813 FRM-LBK-A-003.fm Done Chapter 8 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets 1-9 • PPS Management From the Browser, click the Tools menu button , then click PPS management. Circle the current selections: PPS on RIS/Image Archiver: Selected/Not selected. PPS on CAD: Selected/Not selected If PPS on RIS/Image Archiver is selected, use the table below to record the parameter settings Application Entity Title Network address Port Related Image Archiver If PPS on CAD is selected, use the table below to record the parameter settings Application Entity Title Network address Port Related Image CAD Use the table below to record the PPS Retries settings Number of retries Time before retries (Seconds) Chapter 8 Page no. 814 FRM-LBK-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets 1-10 Needle Setup • From the Browser, click the Tools menu button , then click Needle Setup. From the Needle Panel window that appears, select each of the needles that are listed in the Needle list section, and copy down the needle data that appears in the Needle description section for each of the needles. When completing the table, use the following terms/acronyms for the different needle types: • FNA — FNA • Core Biopsy — CB • Hook — Hook • Vacuum Assisted Divice — VAD • Lateral Approach Tool — LAT The lengths you need to record vary for each needle type. All needles include the A-length parameter, whereas only some needle types include B-length and C-length parameters. In the cases where the parameter does not exist for a particular needle types, simply enter N/A for that parameter. Length (mm) Needle Name Type A B C Note: If the customer has a Mammotome Biopsys or Mammotome ST VAD biopsy devices, perform JCCFG-A001 Needle Setup in the Senographe DS Stereotaxy Service Manual. Page no. 815 FRM-LBK-A-003.fm Chapter 8 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets 1-11 AOP Configuration Use the following steps to query and note down the AOP configuration set on the AWS Computer. 1. From behind the Browser, right click the background, and from the Root Menu that appears, select Service Tools > Command Window to launch a command window. A command window appears with an ADS prompt. 2. Change to the ~sdc/senovision/scripts directory, by entering: cd ~sdc/senovision/scripts 3. Run the setaop.sh script to query the current AOP confinguration, by entering: setaop.sh The setaop.sh script displays the current configuration (either AOP STD TAB_A or AOP STD TAB_B). 4. Note down the current AOP configuration in the table below. AOP Configuration: 5. Close the command window, by entering: exit 1-12 Network Routing Information (S93ROUTE File) From behind the Browser, right click the background, and from the Root Menu that appears, select Service Tools > Command Window to launch a command window 6. View the contents of the /etc/rc2.d/S93route file with the textedit command, by entering: more /etc/rc2.d/S93route If the message file or directory not found appears, no route is set on the system and there is no information that needs recording. If a route has been set, the content of the /etc/rc2.d/S93route file appears of the following format. #!/bin/sh # Section for routing echo Starting route service route add net where is the address to be accessed through the gateway, and is the IP of the gateway (router) indicated by the administrator. More than one route (i.e. route add net) may exist. Note down the route(s) listed in the table below. Route 1 2 3 4 5 From behind the Browser, right click the background, and from the Root Menu that appears, select Service Tools > Command Window to launch a command window. Chapter 8 Page no. 816 FRM-LBK-A-003.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Corrective Maintenance Procedures CHAPTER 9 CORRECTIVE MAINTENANCE PROCEDURES This chapter is intended to help Field Engineers in all aspects of corrective maintenance. It contains the following types of Job Cards: • ERR Error Messages • DIAG Diagnostics • TSG Troubleshooting • REP Repair/Workaround • D/R Disassembly/Reassembly procedures • CFG Configuration • CAL Calibration • CHK Verification/Check Note: While entering the Service Desktop or when performing diagnostics, a small Netscape WARNING window can appear in the upper left-hand corner of the screen while the system is performing some background functions. Ignore the message, it has no effect on the operation of the system. Page no. 817 Chap-Corrective Maintenance.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Corrective Maintenance Procedures This page is blank. Chapter 9 Page no. 818 Chap-Corrective Maintenance.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Scenario CAL A001 - Image Quality Full Calibration Process from Scratch Scenario CAL A001 - Image Quality Full Calibration Process from Scratch 1 • • • 2 Chapter 9 CONTEXT This Scenario shows the complete sequence of calibrations "from scratch" that is followed when integrating the system in the manufacturing facilities before shipment. This calibration process is never performed completely on customer site. Aim of this Scenario: settings made during calibration procedures may interact with others. It may therefore be necessary to carry out other procedures (calibrations or checks) after completing a calibration procedure. These are specified as Post–Completion Requirements in the table below. STEERING GUIDE Calibrations - Checks Job Card Gantry Compression Force Sensor Job Card CAL A048 - Calibration of Compression Force Sensor on page 1709 Compression Thickness Job Card CAL A050 - Compression Thickness Calibration on page 1721 If Compression Thickness not OK, redo calibrations from Compression Force Sensor Acquisition Image Chain Bias Calibration Job Card CAL A003 - X-Ray Tube Focal Bias Voltage Scale Factor on page 1655 Heating Current Calibration Job Card CAL A001 - Heater Current Scale Factor on page 1649 Tube mA Measurement Job Card CAL A009 - X-Ray Tube mA Measurement on page 1663 kV Scale Factor Job Card CAL A011 - Calibration of kV Scale Factor on page 1667 mAs X-Ray Calibration Job Card CAL A012 - X-Ray Tube Heater Current on page 1673 Tube Tilt Calibration Job Card CAL A027 - Tube Tilt Calibration on page 1681 Collimator Calibration Job Card CAL A029 - Collimator Format Calibration on page 1683 Collimation Check Job Card ELE A028 - Collimation Checks on page 679 If Collimation Check not OK, redo Collimator Calibration Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 If IQ Test(s) not OK, redo all calibrations from Bad Pixel. Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 Use the same dosimeter as in CAL A045 AOP: Automatic Optimization of Parameters AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, redo all calibrations from AOP Calibration Page no. 819 SC-CAL-A-001.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Scenario CAL A001 - Image Quality Full Calibration Process from Scratch This page is blank. Chapter 9 Page no. 820 SC-CAL-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Scenario PDR A001 - Post-D/R Procedures Scenario PDR A001 - Post-D/R Procedures 1 • • • Chapter 9 CONTEXT D/R Job Cards are provided where required to describe part replacement procedures. They include any checks and calibrations which must be carried out after replacement ("post-D/R"). Many part replacement procedures are relatively simple and do not require a D/R Job Card (e.g., some board replacements). However, the changing of the part can affect system operation and can therefore require post-D/R calibration and check procedures. This Scenario specifies post-D/R procedures required for part replacement not described in D/R Job Cards. Page no. 821 SC-PDR-A-001.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Scenario PDR A001 - Post-D/R Procedures 2 POST-D/R PROCEDURES 2-1 Control Station 2-1-1 LCD-AWS Monitor • If Stereo or 2D Biopsy Optical Localizer option exists, calibrate the LCD Monitor Monitor Calibrations - Checks Calibrate backlight Job Card Job Card ELE A043 - AWS Monitor Calibration on page 729 2-1-2 Software Backup Kit-IDC • After installing or restoring IDC software, IDC parameters must be restored as described in Job Card ELE A052 - Back-up/Restore Procedure on page 771. If the restore is successful, it is possible to use the system normally without further intervention. • If the restore is not possible or is not successful, the following calibrations and checks must be performed: Calibrations - Checks Job Card Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 If IQ tests not OK, repeat all calibrations from Bad Pixel Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Use the same dosimeter as that used for CAL A046 AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR check not OK, repeat all calibrations from AOP Calibration Chapter 9 Page no. 822 SC-PDR-A-001.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Scenario PDR A001 - Post-D/R Procedures 2-2 Gantry 2-2-1 Light Assembly-Collimator • The following calibrations and checks must be performed after replacement of this component: Calibrations - Checks Collimation Check Job Card Job Card ELE A028 - Collimation Checks on page 679 If the check is not good, perform Job Card CAL A029 - Collimator Format Calibration on page 1683 2-2-2 Filter-Collimation LRS • The following calibrations and checks must be performed after replacement of this component: Calibrations - Checks Job Card Tube Tilt Calibration Job Card CAL A027 - Tube Tilt Calibration on page 1681 Collimator Calibration Job Card CAL A029 - Collimator Format Calibration on page 1683 Collimation Check Job Card ELE A028 - Collimation Checks on page 679 If Collimation Check not OK, repeat Collimator Calibration Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 If IQ tests not OK, repeat all calibrations from Bad Pixel Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Use the same dosimeter as that used for CAL A046 AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR check not OK, repeat all calibrations from AOP Calibration Page no. 823 SC-PDR-A-001.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Scenario PDR A001 - Post-D/R Procedures 2-2-3 Sensor Tube Thermal Cut Out • The following calibrations and checks must be performed after replacement of this component: Calibrations - Checks Job Card Tube Tilt Calibration Job Card CAL A027 - Tube Tilt Calibration on page 1681 Collimator Calibration Job Card CAL A029 - Collimator Format Calibration on page 1683 Collimation Check Job Card ELE A028 - Collimation Checks on page 679 If Collimation Check not OK, repeat Collimator Calibration Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 If IQ tests not OK, repeat all calibrations from Bad Pixel Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Use the same dosimeter as that used for CAL A046 AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR check not OK, repeat all calibrations from AOP Calibration Chapter 9 Page no. 824 SC-PDR-A-001.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Scenario PDR A001 - Post-D/R Procedures 2-2-4 Clamp Tube • If the tube assembly is moved or disturbed when replacing this component, the following calibrations and checks must be performed: Calibrations - Checks Job Card Tube Tilt Calibration Job Card CAL A027 - Tube Tilt Calibration on page 1681 Collimator Calibration Job Card CAL A029 - Collimator Format Calibration on page 1683 Collimation Check Job Card ELE A028 - Collimation Checks on page 679 If Collimation Check not OK, repeat Collimator Calibration Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 If IQ Tests not OK, repeat all calibrations from Bad Pixel. Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Use the same dosimeter as that used for CAL A046 AOP: Automatic Optimization of Parameters AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations from AOP Calibration Page no. 825 SC-PDR-A-001.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Scenario PDR A001 - Post-D/R Procedures 2-2-5 Screw-Tube CL M4x8 • If the tube assembly is moved or disturbed when replacing this component, the following calibrations and checks must be performed: Calibrations - Checks Job Card Tube Tilt Calibration Job Card CAL A027 - Tube Tilt Calibration on page 1681 Collimator Calibration Job Card CAL A029 - Collimator Format Calibration on page 1683 Collimation Check Job Card ELE A028 - Collimation Checks on page 679 If Collimation Check not OK, repeat Collimator Calibration Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 If IQ Tests not OK, repeat all calibrations from Bad Pixel. Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Use the same dosimeter as that used for CAL A046 AOP: Automatic Optimization of Parameters AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations from AOP Calibration Chapter 9 Page no. 826 SC-PDR-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Scenario PDR A001 - Post-D/R Procedures 2-3 Generator Cabinet 2-3-1 Power Supply 50W 5V; see component index page 183 • The following calibrations and checks must be performed after replacement of this component: Calibrations - Checks 5 V dc adjustment Job Card Job Card ELE A005 - Check Supply Voltages on page 541 Page no. 827 SC-PDR-A-001.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Scenario PDR A001 - Post-D/R Procedures This page is blank. Chapter 9 Page no. 828 SC-PDR-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Error Messages ERROR MESSAGES CHAPTER 9 Error message information is given in the following modules: - ERR SUB A001 - Generator Error Messages on page 831 ERR SUB A003 - Gantry Error Messages on page 851 ERR SUB A005 - AWS Error Messages on page 935 ERR SUB A007 - IDC Error Messages on page 937 Page no. 829 Error Messages.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Error Messages This page is blank. Chapter 9 Page no. 830 Error Messages.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A001 - Generator Error Messages ERR SUB A001 - Generator Error Messages 1 Chapter 9 INTRODUCTION This Job Card lists error codes generated by the Generator sub-system and displayed on the X-ray Console. Each message can contain two codes, the User error code and the Service error code (refer to the explanation below). Error codes containing a Service Error Code are listed here; codes containing a User Error code are listed in the Senographe DS Operator Manual. Many messages contain both, and appear in both manuals. Refer to Section 3 Error Code Structure for an explanation of the error code display. Section 4 Generator Error Codes lists the error codes, with corresponding error descriptions. Where possible (mainly for recently developed codes), the list also includes the text of a displayed error message, and suggestions for corrective action. 2 HOW TO VIEW THE ERROR LOG Errors reported by the Generator sub-systems are recorded in a common system error log which also contains error messages generated by the AWS and IDC. To view the error log content, right click the AWS Screen background; select Service Tools/Service Desktop/Error Log from the drop-down menu. 3 ERROR CODE STRUCTURE Error codes are displayed on the X-ray Console in the format shown here:. E 5 5 Error text 1 a bb User error code • • 6 1 0 1 3 ccc ddd Service error code The User Error Code is the code given in the Senographe DS Operator Manual. It is easy to use and communicate, and gives sufficient information for use by the Operator. It includes a code for the type of error (a) and a message number (bb). The example given, E55, indicates that a tube inhalation fault has occurred which caused exposure inhibition, - a: Type of error: I: Warning; exposure not inhibited. S: Warning; exposure inhibited. E: Fault; exposure inhibited. K: Fault; power shut down for safety. - bb: Message number indicating the origin of the fault. The Service Error Code is the code used in this document; it gives more information, and is recommended for use in GE internal communication. It includes two reference codes: - ccc: Indicates the affected subassembly (hardware or software). The example given, 161, indicates a tube housing fault. - ddd: Indicates the origin of the fault The example given, 013, indicates that no reference crossing was detected during tube movement. Page no. 831 ERR-SUB-A-001.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN ERR SUB A001 - Generator Error Messages • • The following abbreviations are used in the error code descriptions: IST: Installation MNT: Maintenance VRTX: Real time operating system Software errors. Many of the codes are described as software errors (e.g., 002/001; Gene. CPU software error). These errors normally never occur. If they do, and especially if they are repeated, contact Service Engineering with as much information as possible. Include a copy of the error codes file on floppy diskette or CD-R. For more information about copying error logs to floppy diskette or CD-R, refer to Job Card DIAG A005 - Error Log Retrieval on page 993. Chapter 9 Page no. 832 ERR-SUB-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN ERR SUB A001 - Generator Error Messages 4 GENERATOR ERROR CODES Code Message text Description 002/001 Gene CPU software error: VRTX error during init 002/002 Gene CPU software error: reboot by watch_dog_hard or reset button 002/003 Gene CPU software error: reboot by watch_dog_soft 002/004 Gene CPU: reboot after power microfailure 003/000 Gene CPU software error: bus error 003/001 Gene CPU software error: address error 003/002 Gene CPU software error: format error 003/003 Gene CPU software error: illegal instruction 003/004 Gene CPU software error: privilege violation 003/005 Gene CPU software error: trace error 003/006 Gene CPU software error: emulation line 1010 error 003/007 Gene CPU software error: emulation line 1111 error 003/008 Gene CPU software error: CHK error 003/009 Gene CPU software error: TRAPV error 004/001 Gene interface: reset error 004/002 Gene interface: read/write error on timer PTM1 004/003 Gene interface: read/write error on timer PTM1 004/004 Gene interface: read/write error on timer PTM2 004/005 Gene interface: read/write error on timer PTM2 004/006 Gene interface: interrupt error on DUART1 004/007 Gene interface: PTM1 timer 1 defective 004/008 Gene interface: PTM1 timer 2 defective 004/009 Gene interface: PTM1 timer 3 defective 004/010 Gene interface: PTM2 timer 1 defective 004/011 Gene interface: PTM2 timer 2 defective 004/012 Gene interface: PTM2 timer 3 defective Page no. 833 ERR-SUB-A-001.fm Recommended actions Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A001 - Generator Error Messages Code Message text Description 004/013 Gene interface: interrupt error on PTM1 timer 1 004/014 Gene interface: interrupt error on PTM1 timer 2 004/015 Gene interface: interrupt error on PTM1 timer 3 004/016 Gene interface: interrupt error on PTM2 timer 1 004/017 Gene interface: interrupt error on PTM2 timer 2 004/018 Gene interface: interrupt error on PTM2 timer 3 D208 006/000 Generator: fault at exposure command 006/001 Generator: fault at exposure command 006/002 Generator: signal kV_Inf_5 (Less_than_5kV) not rising 006/003 Generator: Signal En_Pose (Exposure_On) not rising 006/004 Generator: fatal security triggered during exposure 006/005 Generator: fatal security triggered at end of exposure or signal En_Pose (Exposure_On) stays ’high’ 006/011 Generator: signal Secu_Rattrap (No_Fatal_Security) stays ’high’ after ’arcing recovery’ 006/028 Chapter 9 E20 Check Main Distribution Rack The Mains Distribution Rack is not correctly powered ON. The Low Voltage Power Supply (LVPS) output at the J6 connector is too low to supply the Main Distribution Assembly (expected voltage is 12 Vdc). Recommended actions Proceed as follows: • Reboot the entire system. • If the problem persists, check voltage at LVPS output J6 connector, and adjust to 12 Vdc if required or replace the LVPS. • Reboot the Gantry and check no error code displays on the X-ray Console. Page no. 834 ERR-SUB-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN ERR SUB A001 - Generator Error Messages Code Message text Description 006/029 Wrong value of signal ADS_CART_ON_S TATUS At system power up, the Generator CPU reports the Main Distribution Board has detected the power at the Control Station is not as expected (signal ADS_CART_ON_STATUS is not at yes). 007/xxx E01 Generator failure Gene init tests: one fatal security input 0; xxx identifies input. Access generator error log for full error decoding. Proceed as follows: • check that the Control Station is powered ON • if the problem persists, check the cable connections between the J9 connector on the Main Distribution Board and the XJ11 connector on the Generator Interface Board Possible causes are: 400PL2. • the Control Station is not powered ON • bad connection between J9 connector • if the problem persists, change the Main Distribution Board on the Main Distribution Board and the XJ11 connector on the Generator Interface Board 400PL2. • defective Main Distribution Board 011/001 Focus bias software error: unknown command 011/002 Focus bias software error: unknown task status 012/001 E02 Focus bias fail- Focus bias: signal Pres_Polar ure (Bias_Presence) ’high’ in standby status. 012/002 E02 Focus bias fail- Focus bias: signal Pres_Polar ure (Bias_Presence) stays ’low’ when bias generation starts. 012/003 E02 Focus bias fail- Focus bias: signal Pres_Polar ure (Bias_Presence) goes ’low’ after stabilization. 012/004 E02 Focus bias fail- Focus bias: signal Pres_Polar ure (Bias_Presence) stays ‘high’ after bias generation stopped. 016/001 Anode starter software error: unknown command 016/002 Anode starter software error: unknown task status 017/001 E03 Rotor failure Anode starter: signal Pres_Rotation (Rotation_Presence) ’high’ in standby status 017/002 E03 Rotor failure Anode starter: signal Pres_Rotation (Rotation_Presence) not rising during acceleration to 9000 rpm 017/003 E03 Rotor failure Anode starter: signal Pres_Rotation (Rotation_Presence) not rising during acceleration to 6000 rpm Page no. 835 ERR-SUB-A-001.fm Recommended actions Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A001 - Generator Error Messages Code Message text Description 017/004 E03 Rotor failure Anode starter: signal Pres_Rotation (Rotation_Presence) goes ’low’ during rotation at 9000 rpm 017/005 E03 Rotor failure Anode starter: signal Pres_Rotation (Rotation_Presence) goes ’low’ during rotation at 6000 rpm 017/006 E03 Rotor failure Anode starter: signal Pres_Rotation (Rotation_Presence) goes ’low’ during rotation (speed < 9000 rpm) 017/007 E03 Rotor failure Anode starter: signal Pres_Rotation (Rotation_Presence) goes ’low’ during rotation (speed < 6000 rpm) 017/008 E03 Rotor failure Anode starter: signal Pres_Rotation (Rotation_Presence) stays ’high’ during 9000 rpm braking 017/009 E03 Rotor failure Anode starter: signal Pres_Rotation (Rotation_Presence) stays ’high’ during 6000 rpm braking 017/010 E03 Rotor failure Anode starter: signal Pres_Rotation (Rotation_Presence) stays ’high’ during rotor failure 017/011 E03 Rotor failure Anode starter: signal Pres_Rotation (Rotation_Presence) stays ’low’ during rotation 021/001 Heater software error: unknown command 021/002 Heater software error: unknown task status 021/003 Heater software error: Heater scaling parameters (ICH) or heater values are not valid 022/001 E10 Heating failure track 1 Heater track 1: signal Pres_Chauf (Heater_Presence) ’high’ in standby status 022/002 E10 Heating failure track 1 Heater track 1: signal Pres_Chauf (Heater_Presence) stays ’low’ when the heater started 022/003 E10 Heating failure track 1 Heater track 1: signal Pres_Chauf (Heater_Presence) goes ’low’ during pre-heater phase 022/004 E10 Heating failure track 1 Heater track 1: signal Pres_Chauf (Heater_Presence) goes ’low’ during first trigger 022/005 E10 Heating failure track 1 Heater track 1: signal Pres_Chauf (Heater_Presence) goes ’low’ during exposure Chapter 9 Recommended actions Page no. 836 ERR-SUB-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN ERR SUB A001 - Generator Error Messages Code Message text Description 022/006 E10 Heating failure track 1 Heater track 1: mA value not significant 022/007 E10 Heating failure track 1 Heater track 1: signal Pres_Chauf (Heater_Presence) goes ’low’ after exposure 022/008 E10 Heating failure track 1 Heater track 1: signal Pres_Chauf (Heater_Presence) stays ’high’ when the heater stopped 023/001 E11 Heating failure track 2 Heater track 2: signal Pres_Chauf (Heater_Presence) ’high’ in standby status 023/002 E11 Heating failure track 2 Heater track 2: signal Pres_Chauf (Heater_Presence) stays ’low’ when the heater started 023/003 E11 Heating failure track 2 Heater track 2: signal Pres_Chauf (Heater_Presence) goes ’low’ during pre-heater phase 023/004 E11 Heating failure track 2 Heater track 2: signal Pres_Chauf (Heater_Presence) goes ’low’ during first trigger 023/005 E11 Heating failure track 2 Heater track 2: signal Pres_Chauf (Heater_Presence) goes ’low’ during exposure 023/006 E11 Heating failure track 2 Heater track 2: mA value not significant 023/007 E11 Heating failure track 2 Heater track 2: signal Pres_Chauf (Heater_Presence) ’low’ after exposure 023/008 E11 Heating failure track 2 Heater track 2: signal Pres_Chauf (Heater_Presence) stays ’high’ when the heater stopped 027/003 E04 Arm fatal failure If the problem occurs during boot, check optical fiber between Gantry interface board and generator, also can bus. If the problem occurs when requesting an exposure, check the Bucky. 027/004 E04 Arm fatal failure A Gantry error was signaled during the exposure. Occurs after an exposure when the brightness has been received and the Generator requests the Gantry to put the grid into the home position. If the Gantry does not answer within 3 sec of the request, this error occurs. 1. Reset Gantry and Generator (i.e. press off/on on the X-ray Console). 2. Check other Gantry related errors to determine the route cause. Probable route causes include the Bucky, Collimator, and Filter Wheel. Page no. 837 ERR-SUB-A-001.fm Recommended actions Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A001 - Generator Error Messages Code Message text Description Recommended actions 027/005 E04 Arm fatal failure A Gantry error was signaled during the exposure. Occurs at the end of exposure when the Generator requests the Gantry to stop the grid motion. If the Gantry does not answer within 3 sec of the request, this error occurs. 1. Reset Senographe 2. Check communications between Gantry and Generator. 027/006 E04 Arm fatal failure A Gantry error was signaled during the exposure. 1. Reset Senographe 2. Check communications between Gantry and Generator. 031/001 Generator: delay task software error: unknown command 031/002 Generator: delay task software error: unknown task status 041/001 Gene thermal protection software: VRTX error 041/002 Gene thermal protection software: VRTX error 041/003 Gene thermal protection software: VRTX error 041/004 Gene thermal protection software: VRTX error 041/005 Gene thermal protection software: unknown anode starter status 041/006 Gene thermal protection software: VRTX error 050/043 An unexpected request was received in SysCntrl. 052/001 E04 Arm fatal failure No Gantry acknowledgment to change a filter request. Report the problem to engineering. Check the error logs. If there are any collimator reported errors change the impacted collimator-related FRUs. If there are no collimator reported errors change the other impacted system-related FRUs. 056/001 Focus software error: ACQ_NTR or ACQ_OVR received or unknown reply 056/002 Focus software error: unknown command 056/003 Focus software error: unknown task status Chapter 9 Page no. 838 ERR-SUB-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN ERR SUB A001 - Generator Error Messages Code Message text 057/001 Description Recommended actions Focus: focus change request not transmitted or focus fault. Refer to JC DIAG A1302 TUBE HEAD CONTROL FAILURE on page 965 to fix the problem. The probable causes of the 057/001 error are that the: • HV cable is interacting with the tube framework • tilt movement is restricted • Filter Wheel movement is restricted • Tube Tilt Mechanism is faulty 061/000 Gene. to Gantry communication driver: No Poseidon boot. If the problem perno reply from Gantry after two attempts. sists, change the Gantry CPU Board. If this error occurs in conjunction with the error 063/006 then the Bucky grid has failed to home. In this case you must: - Remove the Bucky - Reset the Senographe - Reconnect the Bucky 062/000 Gene. to control panel communication driver: no reply from control panel after two attempts 063/006 Gene. init tests: no Gantry status feedback after 10 requests No Poseidon boot. If the problem persists, change the Gantry CPU Board. If this error occurs in conjunction with the error 061/000 then the Bucky grid has failed to home. In this case you must: - Remove the Bucky - Reset the Senographe - Reconnect the Bucky 066/000 Gene date/time: access timeout during date init 066/001 Gene date/time: access timeout during read sequence 066/002 Gene date/time: access timeout during write sequence 066/003 Gene date/time: access timeout during time write sequence 067/000 Generator: Zero divide 068/xxx Generator: floating point calculation error. xxx is VRTX task number 071/081 E12 Checksum error Generator: checksum error on battery (gen) saved memory Page no. 839 ERR-SUB-A-001.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A001 - Generator Error Messages Code Message text Description Recommended actions 071/082 E08 Power supply failure Generator: timeout on signal Alim_Puis_OK (Inv_Supply_OK) (going ’low’ or ’high’) Refer to Job Card TSG A020 - Generator Power-Up Sequence Flow Charts on page 1069 071/083 Generator: error reading ’kV law table’ in 0 pt technique (AOP) 072/001 Exposure software error: ACQ_NTR or ACQ_OVR received at start of first trigger 072/003 Exposure software error: ACQ_NTR or ACQ_OVR received at end of first trigger 072/004 Exposure software error: unknown origin of aborted exposure 072/005 Exposure software error: aborted by PM in 2 pt technique 072/006 Exposure software error: unknown exposure technique 072/007 E06 Software Error (gen. CPU) One system task (at least) not stable after a delay of 7 s when a Prep is performed. A Senographe component (tube, rotor, etc.) or IDC is not ready for the exposure (prepStatusOk message not sent to Senographe by IDC). 072/008 Exposure software error: unknown task status 072/009 Exposure software error: 0 pt or 1 pt exposure and Gantry absent 073/001 Gene software error (IST, standby): parameter display problem 073/002 Gene software error (IST, standby): unknown tube type 073/003 Gene software error (IST, standby): alpha=0.0 when calculating value P_NDac_HTPM 073/004 Gene software error (IST, standby): incorrect thickness for correlation calculation 073/005 Gene software error (IST, standby): bias calibration task problem 073/006 Gene software error (IST, standby): heater scale calibration task problem 073/007 Gene software error (IST, standby): HV/ DAC calibration task problem 073/008 Gene software error (IST, standby): FREQ/HV calibration task problem Chapter 9 This error is either caused by IDC or Senographe. When a Senographe sub-system is not ready, there should be a second error message displayed relating to the sub-system causing the error Page no. 840 ERR-SUB-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN ERR SUB A001 - Generator Error Messages Code Message text Description 073/009 Gene software error (IST, standby): PM calibration task problem 073/010 Gene software error (IST, standby): PM calibration task problem 073/011 Gene software error (IST, standby): PM calibration task problem 073/012 Gene software error (IST, standby): PM calibration task problem 073/013 Gene software error (IST, standby): Gantry connection task problem 073/014 Gene software error (IST, standby): Gantry connection fault 073/015 Gene software error (IST, standby): Gantry connection fault 073/016 Gene software error (IST, standby): Gantry connection fault 073/017 Gene software error (IST, standby): mA measurement calibration problem 074/001 Gene software error (IST, exposure): unknown exposure end 074/002 Gene software error (IST, exposure): unknown Gantry reply 074/003 Gene software error (IST, exposure): unknown Gantry reply 074/004 Gene software error (IST, exposure): unknown exposure status 075/010 Gene software error (MNT): anode starter speed impossible 075/011 Gene software error (MNT): anode starter: abnormal test task status 075/020 Gene software error (MNT): heater: impossible track 075/021 Gene software error (MNT): heater: abnormal test task status 075/022 Gene software error (MNT): heater: abnormal test task status 075/030 Gene software error (MNT): bias: abnormal test task status 075/040 Gene software error (MNT): HV test: abnormal test task status 075/041 Gene software error (MNT): gate test: abnormal test task status 075/042 Gene software error (MNT): inverter test: abnormal test task status Page no. 841 ERR-SUB-A-001.fm Recommended actions Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A001 - Generator Error Messages Code Message text Description 075/050 Gene software error (MNT): mA value: abnormal test task status 075/051 Gene software error (MNT): mA measurement: abnormal test task status 075/060 Gene software error (MNT): grid sync: abnormal test task status 075/070 Gene software error (MNT): PM test: abnormal test task status 075/071 Gene software error (MNT): PM test: abnormal test task status 075/072 Gene software error (MNT): PM test: measurement timeout 075/090 Gene software error (MNT): error codes: display problem 075/091 Gene software error (MNT): error codes: display problem 075/092 Gene software error (MNT): error codes: display problem 075/093 Gene software error (MNT): error codes: display problem 075/100 Gene software error (MNT): transfer: frame code error 075/101 Gene software error (MNT): transfer: abnormal transfer task (save) status 075/102 Gene software error (MNT): transfer: abnormal transfer task (save) status 075/103 Gene software error (MNT): transfer: abnormal state transfer task (load) status 075/104 Gene software error (MNT): transfer: abnormal state transfer task (load) status 075/105 Gene software error (MNT): transfer: unknown frame 075/106 Gene software error (MNT): transfer: end of loading error 075/107 Gene software error (MNT): transfer: abnormal transfer task (protocol) status 078/002 Gene init tests software error: timeout on system task 078/003 Gene init tests software error: defective function will self-identify 078/004 Gene init tests software error: defective function will self-identify Chapter 9 Recommended actions Page no. 842 ERR-SUB-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN ERR SUB A001 - Generator Error Messages Code Message text Description 078/005 Gene init tests software error: defective function will self-identify 078/128 Gene init tests software error: error following VRTX request 079/001 Exposure aborted: timeout 079/002 Exposure aborted: heater fault 079/003 Exposure aborted: anode starter fault 079/004 Exposure aborted: power fault 079/005 Exposure aborted: generator fault 079/006 Exposure: no Gantry acknowledgment (at start of first trigger) or Gantry fault 079/008 Gantry fault detected before start of exposure 079/009 Exposure: no sync signal from Gantry to start exposure 079/010 Exposure aborted by mA meter (0 pt or 1 pt technique) 079/011 E04 Arm fatal failure Exposure: no Gantry acknowledgment (at end of first trigger) or Gantry fault Recommended actions If the problem occurs during boot, check optical fiber between Gantry interface board and generator, also can bus. If the problem occurs when requesting an exposure, check the Bucky. Check the error logs. If there are any collimator reported errors change the impacted collimator-related FRUs. If there are no collimator reported errors change the other impacted system-related FRUs. 079/013 E05 Failure Before Exposure Between AOP pre-exposure and AOP exposure, the Generator sends a StartSequence message to the IDC and launches a timeout of 1200 ms. If the Generator does not see the RT signal XRAY_AUTHORIZE rising during this timout, it generates error E05 079/013. Probable cause: 1. Board or RT0 connector on IDC aulty. 2. IDC-Generator RT/COM cable (2244615) faulty. 3. Generator board issue/faulty. 079/014 E05 Failure during exposure Falling XRayAuthorizedRT signal not received from IDC Page no. 843 ERR-SUB-A-001.fm From the Service Desktop, perform the IDC DMR - RT Line diagnostics using the loopback connectors from the Loopback Kit. If the problem persists, additionally try adding DB9 Adaptors to the DB9 sockets on the IDC rear panel (see Job Card TSG A012 - Use of DB9 Adaptors to Reduce Intermittent IDC or ADS Communication Errors on page 1029). Switch the system off and on again; repeat the exposure. Check the IDCSenographe communication Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A001 - Generator Error Messages Code Message text Description 079/015 E05 Failure during exposure The Generator has not received exposure information from IDC after 15 seconds during an X-ray exposure. This error occurs only during an X-ray exposure. Switch Off the system. Switch On again; repeat the exposure. 079/017 E16 AWS/SENO Synchro fail The acquisition was not correctly performed on ADS (image not correctly transferred from IDC, for example) Reset system and try again. If the error persists, check AWS is running correctly; try rebooting AWS and Senographe. On V3 or V4 Control Stations (U20 or Z400), if the problem persists, additionally try adding DB9 Adaptors to the DB9 sockets on the ADS rear panel (see Job Card TSG A012 - Use of DB9 Adaptors to Reduce Intermittent IDC or ADS Communication Errors on page 1029). 079/018 I41 Arm error during exposure Can occur during exposure when there is a problem with the Positioner. Reboot the Senographe system. If the problem persists, contact your OLC. 079/019 E05 Failure during pre-exposure The Generator has not received preexposure information from IDC after 15 seconds. Switch Off the system. Switch On again; repeat the exposure. 079/021 E25 AWS/SENO Synchro. fail AWS did not sent acknowledgment to DMR preparation phase request within 3 seconds. Reboot the Senographe system. If the problem persists, contact your OLC. 080/001 Gene (IST, exposure): heater fault 080/002 Gene (IST, exposure): anode starter fault 080/003 Gene (IST, exposure): power failure 080/004 Gene (IST, exposure): interface fault 080/005 Gene (IST, exposure): no Gantry reply timeout after 1 second 080/006 Gene (IST, exposure): Gantry fault 080/007 Gene (IST, exposure): no Gantry reply to exposure command 080/008 Gene (IST, exposure): no grid sync feedback after timeout 080/011 The x-ray-authorize RT signal falls during an exposure 082/000 Gene: ’Endurance’ error code 082/001 Gene: ’Endurance’ error code 082/010 Gene: ’Endurance’ error code 082/020 Gene: ’Endurance’ error code 082/030 Gene: ’Endurance’ error code Chapter 9 Recommended actions Refer to Job Card TSG A027 - 080/ 011 Error Trouble Shooting on page 1083. Page no. 844 ERR-SUB-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN ERR SUB A001 - Generator Error Messages Code Message text 082/040 Description Recommended actions Gene: ’Endurance’ error code Senographe/AWS communication failure: the Senographe did not receive any message from AWS during a period of 2 minutes. Check Senographe/AWS connections. On V3 or V4 Control Stations (U20 or Z400), if the problem persists, additionally try adding DB9 Adaptors to the DB9 sockets on the ADS rear panel (see Job Card TSG A012 - Use of DB9 Adaptors to Reduce Intermittent IDC or ADS Communication Errors on page 1029). 083/002 I17 AWS./SENO Comm. lost 084/008 E24 Failure before exposure. • In manual exposure mode Contact OLC. Arm exposure synchronization error which occurs before X-ray emission but after the Radiography key has been pressed. Error related to the arm synchronization signal (grid synchronization) that is not correctly received by the exposure automaton from the Gantry or Bucky. • In AOP pre-exposure mode 1. Occurs before X-ray emission: It's due to the arm synchronization signal (grid synchronization) that is not correctly received by the exposure automaton from the Gantry or Bucky. 2. Occurs in the middle of the pre-exposure X-ray emission: It's due to tube arcing. 084/009 E24 Failure before exposure. An error occurred before X-ray emission but after the Radiography key has been pressed. Relating to a signal not correctly received by the exposure automaton from the IDC or Gantry. This error is caused by the IDC or the Gantry. Reboot the entire system and check IDC-Senographe communications. 084/013 E24 Failure before exposure. An error occurred before X-ray emission but after the Radiography key has been pressed. Relating to a signal not correctly received by the exposure automaton from the IDC or Gantry. From the Service Desktop, perform the IDC DMR - RT Line diagnostics using the loopback connectors from the Loopback Kit. Probable cause: 1. Board or RT0 connector on IDC aulty. 2. IDC-Generator RT/COM cable (2244615) faulty. 3. Generator board issue/faulty. 090/000 Generator: PROM checksum error Page no. 845 ERR-SUB-A-001.fm If the problem persists additionally, try adding DB9 Adaptors to the DB9 sockets on the IDC rear panel (see Job Card TSG A012 - Use of DB9 Adaptors to Reduce Intermittent IDC or ADS Communication Errors on page 1029). Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A001 - Generator Error Messages Code Message text Description 092/000 I19 IDC/Seno comm. lost. Communication error between the Generator and IDC: the connection is lost (no answer from IDC for 15 seconds). If the error condition continues for 2 minutes, E19 appears. Probable cause: 1. Board or COM2 connector on IDC faulty. 2. IDC-Generator RT/COM cable (2244615) faulty. 3. IDC-Generator Serial cable (2226613) faulty. 4. Generator board issue/faulty. 092/000 E19 IDC/Seno down, DPS is off. Communication error between the Generator and IDC: the connection is lost (no answer from IDC for 2 minutes). When this error occurs, the detector power supply is set off. Recommended actions From the Service Desktop, perform the IDC DMR - Serial Line diagnostics using the loopback connectors from the Loopback Kit. If the problem persists additionally, try adding DB9 Adaptors to the DB9 sockets on the IDC rear panel (see Job Card TSG A012 - Use of DB9 Adaptors to Reduce Intermittent IDC or ADS Communication Errors on page 1029). From the Service Desktop, perform the IDC DMR - Serial Line diagnostics using the loopback connectors from the Loopback Kit. Probable cause: 1. Board or COM2 connector on IDC faulty. 2. IDC-Generator RT/COM cable (2244615) faulty. 3. IDC-Generator Serial cable (2226613) faulty. 4. Generator board issue/faulty. 092/001 Chapter 9 E19 IDC/Seno down, DPS is off. The Generator attempts to send a serial message to the IDC. If the IDC refuses to accept this serial message after 50 attempts, this error is raised. From the Service Desktop, perform the IDC DMR - Serial Line diagnostics using the loopback connectors from the Loopback Kit. Probable cause: 1. Board or COM2 connector on IDC faulty. 2. IDC-Generator RT/COM cable (2244615) faulty. 3. IDC-Generator Serial cable (2226613) faulty. 4. Generator board issue/faulty. If the problem persists additionally, try adding DB9 Adaptors to the DB9 sockets on the IDC rear panel (see Job Card TSG A012 - Use of DB9 Adaptors to Reduce Intermittent IDC or ADS Communication Errors on page 1029). Page no. 846 ERR-SUB-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN ERR SUB A001 - Generator Error Messages Code Message text Description Recommended actions 092/002 E19 IDC/SENO inactive - DPS off The Generator attempts to send messages to the IDC via the serial, with a timeout of the order of 1 second. If the Generator fails to send messages to the IDC after three attempts this error is raised. Check that the IDC is running (via the Service Desktop), and reboot the Generator. When this error is raised the Generator cuts power to the detector via the DPS, the IDC sees that the DPS is powered down, so the IDC reboots and restarts the DPS power. Probable cause: 1. IDC filter dirty, so IDC processor may be running hot and communications to the Generator may be slow. 2. Board or COM2 connector on IDC faulty. 3. IDC-Generator RT/COM cable (2244615) faulty. 4. IDC-Generator Serial cable (2226613) faulty. 5. Generator board issue/faulty. 092/003 E19 IDC/Seno down, DPS is off. If the problem persists, proceed as follows: 1. If you have a Dione5 IDC, clean the IDC filter according to Job Card PM A425 - IDC Air Filter Cleaning on page 1803. 2. Check the IDC-Generator RT/COM cable (2244615) between the IDC and Gantry bulkhead. 3. Check the IDC-Generator Serial cable (2226613) between the Gantry bulkhead and Generator. 4. From the Service Desktop, perform the IDC DMR - Serial Line diagnostics using the loopback connectors from the Loopback Kit. 5. If the problem persists, check the error logs to see if any other errors occur in conjuction with this error. Depending on the the associated errors, change either the IDC or the appropriate board within the Generator. If 5 minutes after the IDC has booted, there is no communication at all between the IDC and Generator, this error is raised. From the Service Desktop, perform the IDC DMR - Serial Line diagnostics using the loopback connectors from the Loopback Kit. Probable cause: 1. Board or COM2 connector on IDC faulty. 2. IDC-Generator RT/COM cable (2244615) faulty. 3. IDC-Generator Serial cable (2226613) faulty. 4. Generator board issue/faulty. If the problem persists additionally, try adding DB9 Adaptors to the DB9 sockets on the IDC rear panel (see Job Card TSG A012 - Use of DB9 Adaptors to Reduce Intermittent IDC or ADS Communication Errors on page 1029). Check Senographe/AWS connections, perform comm diagnostics 094/001 E18 IDC/Seno synchro failure. An error occurs on IDC or on Senographe which generates an error on a signal/message expected from the IDC task of the Senographe: bad command received by the IDC task 094/002 E18 IDC/Seno synchro failure. Check communication between IDC An error occurs on IDC or on and Senographe, perform comm Senographe which generates an error on a signal/message expected from the diagnostics, perform IDC diagnostics IDC task of the Senographe: Prep command not received by the IDC task Page no. 847 ERR-SUB-A-001.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A001 - Generator Error Messages Code Message text Description Recommended actions 094/003 E18 IDC/Seno synchro failure. Check communication between IDC An error occurs on IDC or on and Senographe, perform comm Senographe which generates an error on a signal/message expected from the diagnostics, perform IDC diagnostics IDC task of the Senographe: Stop command at end of exposure not received by the IDC task. 094/004 E18 IDC/Seno synchro failure. An error occurs on IDC or on Senographe which generates an error on a signal/message expected from the IDC task of the Senographe: XRayAuthorizedRT status not received by the IDC task. 094/005 E18 IDC/Seno synchro failure. Check communication between IDC An error occurs on IDC or on and Senographe, perform comm Senographe which generates an error on a signal/message expected from the diagnostics, perform IDC diagnostics IDC task of the Senographe: Stop command not received by the IDC task at the end of the Radiography. 094/006 E18 IDC/Seno synchro failure. An error occurs on IDC or on Senographe which generates an error on a signal/message expected from the IDC task of the Senographe: Prep command not received by the exposure automaton (task T_APPLI) Check communication between IDC and Senographe, perform comm diagnostics, perform IDC diagnostics. Check communication between IDC and Senographe, perform comm diagnostics, perform IDC diagnostics If the problem persists, additionally try adding DB9 Adaptors to the DB9 sockets on the IDC rear panel (see Job Card TSG A012 - Use of DB9 Adaptors to Reduce Intermittent IDC or ADS Communication Errors on page 1029). 094/007 E18 IDC/Seno synchro failure. An error occurs on IDC or on Senographe which generates an error on a signal/message expected from the IDC task of the Senographe: XRayAuthorizedRT signal active in idle status Check communication between IDC and Senographe, perform comm diagnostics, perform IDC diagnostics 096/019 I34 Thickness out of AOP range Thickness out of AOP range. None (warning only) 096/020 I36 IFF threshold out of range IFF (IDC algorithm) threshold out of range. None (warning only) 096/021 I37 9 param model deviate Error on Scf factor for the pre-exposure Warning given in AOP mode between pre-exp. and exposure, if the corrected mechanical thickness is equal to 0 or breast composition is out of the range 0.6 to 1.4. Check consistency between radiological and mechanical thickness after pre-exposure. Check gene. display. 096/023 I05 Exposure aborted by mAs level mAs value performed for the pre-exposure out of range Reboot the full system. Chapter 9 Page no. 848 ERR-SUB-A-001.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A001 - Generator Error Messages Code Message text 096/024 I06 Abort: Detect sig. out range 096/025 I08 Track/filter change 096/033 I11 096/038 Description Recommended actions Dose value returned by IDC out of range Reboot the full system. Track/filter configuration changed between the pre-shot and the exposure None (warning only). IDC sent an invalid dose value to the Senographe. Reset the entire system and retry the exposure. I31 Abort: Image signal too low Image signal too low. Occurs in AOP mode, between preexp and exposure, if the dose sent by IDC is out of permitted range. Check: Mechanical thickness. Paddle type used. Presence of implant or marking in the breast. That paddle is located in the center of the trolley support. That the paddle type is not changing during compression (paddle label position not correct). 096/039 I32 Abort: Image signal too high Image signal too high. Occurs in AOP mode, between preexp and exposure, if the dose sent by IDC is out of permitted range. Check: Mechanical thickness. Paddle type used. Presence of implant or marking in the breast. That paddle is located in the center of the trolley support. That the paddle type does not change during compression (paddle label position not correct). 096/040 I33 Abort No AOP zone Exposure aborted; no AOP zone estab- Check for presence of breast implant. lished. 096/041 I38 Thermal limit: mAs not optimal Due to the system thermal condition, the exposure mAs value has been reduced to be within the regular Image Quality limits. None (warning) 096/042 I39 Exp. time limit: mAs not optimal Due to exposure time limit, the exposure mAs value has been reduced to be within the regular Image Quality limits. None (warning) 096/043 I40 Exp. time limit: risk mAs too low Maximum exposure time reached; the exposure mAs value has been reduced more than the regular Image Quality limits. None (warning) Page no. 849 ERR-SUB-A-001.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A001 - Generator Error Messages Code Message text Description Recommended actions 096/044 I60 Detector sig. out of range This error is raised during an exposure in AOP mode if the Generator receives: • a dose value from the detector that is outside of the authorized limits or • a null dose value from the detector Probable cause is that the CF calibration is bad. Perform Job Card CAL A045 - Conversion Factor Measurement on page 1701. This error is raised during an exposure in AOP mode if the Generator receives an IFF status not OK from IDC (i.e. signal too low, signal too high or no AOP zone found). Occurs if the signal is too low, too high or if no AOP zone is found during the IFF computation. Check: Mechanical thickness. Paddle type used. Presence of implant or marking in the breast. That paddle is located in the center of the trolley support. That the paddle type is not changing during compression (paddle label position not correct). If the problem persists, contact your OLC. 096/045 I60 Detector sig out of range 097/026 I48 U-turn before end of pre-shot. The exposure time for the pre-shot (AOP mode) is greater than the grid motion duration to the first turn-back point. None (warning). 097/027 I49 U-turn before end of exposure. The exposure time (manual and AOP mode) is greater than the grid motion duration to the first turn-back point. None (warning). 098/044 I60 Detector sig. out of range This error is raised during an exposure in Manual mode if the Generator receives: • a dose value from the detector that is outside of the authorized limits or • a null dose value from the detector Probable cause is that the CF calibration is bad. Perform Job Card CAL A045 - Conversion Factor Measurement on page 1701. This error is raised during an exposure in MANUAL mode if the Generator receives an IFF status not OK from IDC (i.e. signal too low, signal too high or no AOP zone found). Occurs if the signal is too low, too high or if no Glandular zone is found during the IFF computation. Check: Mechanical thickness. Paddle type used. Presence of implant or marking in the breast. That paddle is located in the center of the trolley support. That the paddle type is not changing during compression (paddle label position not correct). 098/045 Chapter 9 I60 Detector sig out of range If the problem persists, contact your OLC. Page no. 850 ERR-SUB-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages ERR SUB A003 - Gantry Error Messages 1 HOW TO VIEW THE ERROR LOG 2 WARNING MESSAGE STRUCTURE Chapter 9 A Warning message is composed of: • Code: numeric abc/def • Text: displayed in the Error Log File or on AWS LCD Monitor • Recommended actions. Page no. 851 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages 3 GANTRY WARNING MESSAGES 3-1 Error Codes from 100/yyy: Lift Code Category Text in Log File or on LCD Possible Cause/Recommended Action 100/001 HALT LIFT HARDWARE ERROR There is a relay defect at power-up. A relay (on the board) is mounted in parallel with the H-bridge of the motor. When this relay is closed it creates a short-cut of the H-bridge. At power-up, the lift node injects 15 V to the H-Bridge, shuts the relay and checks that there is 0 V. The lift node re-opens the relay and checks that there is 15 V. If the lift node does not perform this routine, this error is produced. Job Card This error typically occurs in conjunction with a HALT POSTION error (such as rotation, compression, etc.), in which case the Lift Board is not faulty. Proceed as follows: 1. Reboot the system. Check the error logs to see whether the 100/001 LIFT HARDWARE ERROR occurs within the same time as another POSITION ERROR (e.g. rotation or compression). 2. If a POSITION ERROR (e.g. rotation or compression) does exist within the same time, ignore the 100/001 LIFT HARDWARE ERROR. Do not change the Lift Board, and take appropriate action to resolve the POSITION ERROR. 3. If a POSITION ERROR (e.g. rotation or compression) does not exist within the same time, the 100/001 LIFT HARDWARE ERROR is valid. You must change the Lift Board and then recalibrate the Lift. 100/002 HALT LIFT SENSOR DEFECT D/R A201 page 1161 CAL A031 page 1687 Upper Optical Fork failure. At power-up, the lift node shuts down the LED of the optical fork, and checks that the photoresistor shuts down. Optical forks are hardware limits hence they are never obturated. Faulty FRU = Upper Optical Fork. Change the FRU and reboot Gantry. 100/003 HALT LIFT SENSOR DEFECT Lower Optical Fork failure. At power-up, the lift node shuts down the LED of the optical fork, and checks that the photoresistor shuts down. Optical forks are hardware limits hence they are never obturated. Faulty FRU = Lower Optical Fork. Change the FRU and reboot Gantry. Chapter 9 Page no. 852 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 100/004 WARNING FOOTSWITCH IS PRESSED 100/005 WARNING FOOTSWITCH IS PRESSED 100/006 WARNING FOOTSWITCH IS PRESSED 100/007 WARNING FOOTSWITCH IS PRESSED UIF Still Pressed [i] (for i =1 - 4) = Occurs when one of the 2 (resp 4) buttons on footswitches are pressed during node boot-up: - Lift up: 0x9006 - Lift down: 0x9005 (- Compression up): 0x9008 (- Compression down): 0x9007 Right or left are not differentiated. Double Footswitch concerns 2 error signals and quadruple footswitches concerns 4 error signals Job Card A1001 page 945 See JC DIAG A1001 FOOTSWITCH IS PRESSED on page 945 to fix the problem. 100/009 HALT LIFT POSITION ERROR The Lift is over the upper software limit. Occurs when the lift position is not between the software limits at power-up (including a tolerance to be defined). Typically, this can happen when the lift has been moved manually. Remove the Gantry covers; check the lift position. If lift position locked into upper position, or close to the upper position, move the lift down manually. To do this, turn the lift screw to about 2 cm below the upper optical fork. 100/010 HALT LIFT POSITION ERROR The Lift is below the lower software limit. Occurs when the lift position is not between the software limits at power-up (including a tolerance to be defined). Typically, this can happen when the lift has been moved manually. Remove the Gantry covers; check the lift position. If the lift position locked into lower position, or close to the lower position, move the lift up manually. To do this, turn the lift screw to about 2 cm below the upper optical fork. 100/011 WARNING GANTRY DISPLAY FAILURE The LCD has failed. Faulty FRU = LCD Reboot the system from the X-ray Console. If the problem persists, change the LCD. 100/013 N/A RELAY DEFECT When the node moves to operational state it checks if the relay state is according to the board safety state (for example missing STOP_MOTION_LINE has to disable the relay). This error is triggered, when there are no safety problems on the board, but, for some reason, the relay doesn't allow motion. Probable root cause: Broken or stucked relay The board shall be changed. Page no. 853 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 101/001 DEBUG ONLY LIFT SOFTWARE ERROR On every command sent by the PTB, the IPMS checks whether the command identifier is part of the list of commands to be taken into account by IPMS. If the command is not recognized, the command is ignored, and “CommandIdError” is returned. Job Card Should not occur in the field. It could be a disconnect between the CPU soft release and the Node soft release. Contact your OLC if the problem persists. 101/002 DEBUG ONLY LIFT SOFTWARE ERROR On every command sent by the PTB, the IPMS checks whether all parameters values are compatible with their corresponding range. If not, the command is be ignored, and “ParameterError” is returned to the PTB. Should not occur in the field. It could be a disconnect between the CPU soft release and the Node soft release. Contact OLC if the problem persists. 101/003 WARNING LIFT CALIBRATION ERROR If the calibration is not achieved, for each CAN mes- CAL A031 page sage which is not a calibration command, the IPMS 1687 ignores the command and sends the “CalibrationNotAchieved” error. Use Job Card CAL A031 - Lift Calibration on page 1687 to perform a Lift calibration. 101/004 WARNING NO VALID LINE FOR LIFT There is no valid line. The Gantry CPU requests a motion but node does not see the valid line. The valid line is an RT line, that is activated by the CPLD of the node containing the UIF during the time when the UIF is pressed + a deceleration time. This does not concern decompression and tilt. This also occurs when the valid line falls before the end of the movement. A1015 page 949 Valid line problem. check the different motions, using all keypads to determinate the defective node then refer to JC DIAG A1015 LIFT CONTROL FAILURE on page 949. Chapter 9 Page no. 854 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 101/005 DEBUG ONLY KEYBOARD FAILURE When pressing a UIF, the IPMS starts a timer on the node concerned by the motion. If the “Start motion” command is received before the delay has expired, motion is authorized, otherwise an error is transmitted to Poseidon”. Delay is 100 ms. This requirement does not apply for tilt node and decompression motion. Occurs when CPU sends a "Start Motion" to the node whereas no previous command on CAN towards the CPU is read by the node before. Job Card 1. Try other motions (rotation for example), if the button not pressed appears as well, there is a CAN communication problem. 2. Otherwise, try same lift motion but by pressing other buttons than the initial one. - if the button not pressed appears as well, the faulty FRU is the Lift board - if the button not pressed appears only when the initial Lift button is pressed then the faulty FRU is the board linked to the UIF that has been pressed for the motion. For, example the faulty FRU is the Lift board, Compression board, or Tube Tilt board. 3. Lift, Compression, or Tilt recalibration is requested following corresponding board replacement. 102/000 HALT LIFT SOFTWARE ERROR The watch-dog receives a pulse from microcontroller every 40 ms. If not, it resets the microcontroller, node restarts and sends a boot-up signal to Gantry CPU. The only possible reason for a boot-up of a node after system power-up is a reset by watchdog. Therefore, when Gantry CPU receives the boot-up signal, it produces the SWOverRun error. This failure is linked to a firmware problem (microcontroller or CPLD). Change the Lift board then perform Lift Calibration. 102/001 HALT LIFT POSITION ERROR There is a Potentiometer defect. Lift node checks that the signal coming from the potentiometer is within an acceptable range. D/R A201 page 1161 CAL A031 page 1687 A1004 page 946 See JC DIAG A1004 LIFT CONTROL FAILURE on page 946 to fix the problem. Page no. 855 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action Job Card 102/002 HALT LIFT SPEED ERROR When a coding wheel defect is detected through the complemented hardware (HW) lines, the IPMS stops and forbids the motion and sends an error message. A1005 page 946 See JC DIAG A1005 LIFT CONTROL FAILURE on page 946 to fix the problem. 102/04 HALT LIFT LOWSPEED The signal coming from motor encoder contains four phases. A, A complementary, B, B complementary. The Lift node checks two things: complementarity + sequence of phases. A1013 page 948 Check the lift operation in low speed and then refer to JC DIAG A1013 LIFT CONTROL FAILURE on page 948 to fix the problem. 102/005 HALT UNCONTROLLED LIFT MOTION There has been a Correlation Error. In case signals from absolute coder (potentiometer) and coding wheel (motor encoder) are not correlated. A1008 page 947 Refer to JC DIAG A1008 LIFT CONTROL FAILURE on page 947 to fix the problem. 102/006 HALT LIFT FOOTSWITCH DEFECT 102/007 HALT LIFT FOOTSWITCH DEFECT 102/008 HALT COMPRESSION FOOTSWITCH DEFECT 102/009 HALT COMPRESSION FOOTSWITCH DEFECT SwitchDefect [i] (for i = 1 - 4) occurs when the two signals from the button do not arrive at the same time on the CPLD. [i] indicates the nature of the button and the side right or left. Double Footswitch concerns 2 error signals and quadruple footswitches concerns 4 error signals: - Lift up - Lift down (- Compression up) (- Compression down) A1001 page 945 Refer to JC DIAG A1001 FOOTSWITCH IS PRESSED on page 945 to fix the problem. 102/010 HALT LIFT OVER UPPER LIMIT The IPMS detected that a motion has reached the upper electrical stop limit. It stops and, forbids the motion and sends an error message. A1008 page 947 Refer to JC DIAG A1008 LIFT CONTROL FAILURE on page 947 to fix the problem. 102/012 HALT LIFT OVER LOWER LIMIT The IPMS detected that a motion has reached the lower electrical stop limit. It stops, and forbids the motion and sends an error message. A1008 page 947 Refer to JC DIAG A1008 LIFT CONTROL FAILURE on page 947 to fix the problem. Chapter 9 Page no. 856 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action Job Card 102/013 HALT LIFT OVERSPEED The lift speed measured by the encoder is too high in relation to the speed profile (and correlation is OK). A1012 page 948 Refer to JC DIAG A1012 LIFT CONTROL FAILURE on page 948 to fix the problem. 102/014 WARNING LIFT LOWSPEED The lift speed measured by the encoder is too low in relation to the speed profile (and correlation is OK). A1013 page 948 Check the lift operation in low speed and then refer to JC DIAG A1013 LIFT CONTROL FAILURE on page 948 to fix the problem. 102/015 HALT LIFT OVER CURRENT Occurs when an integrated value of the current is too high, that is when the current is too high during too much time. A1011 page 947 Refer to JC DIAG A1011 LIFT CONTROL FAILURE on page 947 to fix the problem. 102/016 DEBUG ONLY Movement already in progress Occurs when node is performing a movement, and the Gantry CPU sends a command for another movement when the first movement is not finished. This is a CPU problem because the CPU did not wait to send the next movement command. Should not occur in the field. There could be an incompatibility between the CPU software release and the Node software release. Contact your OLC if the problem persists. 102/017 102/018 102/019 HALT HALT N/A LIFT NODE FW INCOMPATIBILITY LIFT NODE PARITY ERROR STOP LINE WAS ACTIVATED BECAUSE OF UNCONTROLLED MOTION There is an Invalid Node Type. Occurs when the hardware configuration (CPLD) of the node or the DSP or the MCU firmware not match. D/R A201 page 1161 Change the Lift board then perform Lift Calibration. CAL A031 page 1687 There is a Parity error. Occurs when the parity bit does not set correctly on the on-board bus between the CPLD and the MCU. D/R A201 page 1161 Change the Lift board then perform Lift Calibration. CAL A031 page 1687 Same as error 102/004. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. Page no. 857 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 102/020 N/A STOP LINE WAS ACTIVATED BY CPU Possible Cause/Recommended Action Job Card The main CPU detected an error and activated the stop motion line or did not deactivated it at all. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 102/021 102/022 HALT HALT LOW VOLTAGE ERROR ON LIFT NODE LIFT READ TIMEOUT ERROR There is a low voltage error. If the voltage of the power supply falls below 24 V the node sends this error. D/R A201 page 1161 Change the Lift board then perform Lift Calibration. CAL A031 page 1687 The MCU has not reacted on the interrupt request (IRQ) coming from the CPLD before 15 ms. D/R A201 page 1161 Change the Lift board then perform Lift Calibration. CAL A031 page 1687 102/023 HALT LIFT CPLD MEMORY ERROR There is a CPLD memory error. Test data from the CPLD is periodically read to ensure the proper communication. If this error does not match the node sends this error. Change the Lift board then perform Lift Calibration. 102/024 HALT UNCONTROLLED LIFT MOTION DETECTED. STOP LINE ACTIVATED There has been uncontrolled motion. If the motion is performed when the lift node is not supposed to drive it, the lift node sends this error and activates the MCU_STOP_MOTION line which leads to 0x500A error. D/R A201 page 1161 CAL A031 page 1687 A1013 page 948 1. Check the lift operation in low speed. 2. If the problem persists, grease the lift screw. 3. If the problem persists, refer to JC DIAG A1013 LIFT CONTROL FAILURE on page 948 to fix the problem. Chapter 9 Page no. 858 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action Job Card 102/025 HALT LIFT RELATIVE ENCODER ERROR Possible causes: • There is a relative encoder error. The signal coming from the relative encoder does not evolves during the motion while the signal coming from the absolute encoder does. • This error can be also due to a mechanical play of the lift screw; or because the gas spring could have failed. D/R A205 page 1179 Proceed as follows: 1. Change the Lift Motor + Encoder + Cable (see Job Card D/R A205 - Lift Motor on page 1179). 2. If the problem persists, change the Lift Potentiometer + Cable (see Job Card D/R A204 - Lift Potentiometer on page 1175). 3. If the problem persists, change the Lift Gas Spring (Job Card D/R A206A - Lift Gas Spring on page 1183). 102/026 HALT LIFT ABSOLUTE ENCODER ERROR The lift potentiometer is faulty and generating too much noise. D/R A204 page 1175 D/R A206A page 1183 D/R A204 page 1175 Change the Lift Potentiometer and Cable (see Job Card D/R A204 - Lift Potentiometer on page 1175) 102/027 102/028 WARNING WARNING LIFT MCU CALIBRATION DATA CORRUPT The MCU calibration data is corrupt. The checksum on the calibration data stored by the MCU does not match. CAL A031 page 1687 Perform a Lift calibration. If the problem persists, change the lift board. D/R A201 page 1161 LIFT DSP CALIBRA- The DSP calibration data is corrupt. The checksum TION DATA COR- on the calibration data stored by the DSP does not RUPT match. Perform a Lift calibration. If the problem persists, change the lift board. 102/029 HALT LIFT MCU EEPROM FAILURE D/R A201 page 1161 There has been an MCU EEPROM failure. The read- D/R A201 page back on the newly written data to the EEPROM has 1161 failed. Change the Lift board then perform Lift Calibration. Page no. 859 ERR-SUB-A-003.fm CAL A031 page 1687 CAL A031 page 1687 Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 102/030 DEBUG ONLY LIFT POSITION ERROR Possible Cause/Recommended Action There is a position error. The motion did not stop at the target/limit position and went further than the allowed margin. Job Card A1014 page 948 Refer to JC DIAG A1014 LIFT POSITION OVERSHOOT on page 948 to fix the problem. 102/031 WARNING LIFT DECELERATION ERROR There is a deceleration error. The motion began to slow down but did not stop before the allowed time. A1014 page 948 Refer to JC DIAG A1014 LIFT POSITION OVERSHOOT on page 948 to fix the problem. 102/032 HALT LIFT MOTION STARTED IN REVERSE DIRECTION The motion was about to go in the reverse direction to what was requested. D/R A201 page 1161 Change the Lift board then perform Lift Calibration. CAL A031 page 1687 102/033 102/034 HALT WARNING LIFT DSP TIMEOUT The Lift DSP did not answer to the MCU before the timeout. D/R A201 page 1161 Change the Lift board then perform Lift Calibration. CAL A031 page 1687 LIFT CAN COMMAND NOT PROCESSED CAN command not processed. The Gantry CPU sent command to the lift node before the lift node could acknowledge the previous command. Reboot the system from the X-ray Console. Retry the command. If the problem persists, contact your OLC. 102/035 HALT LIFT RX CAN BUFFER OVERRUN There has been a CAN overrun. The input queue of the incoming CAN messages of the MCU is full and the message dropped. Should not occur in field. If this error occurs contact your OLC. Chapter 9 Page no. 860 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 102/036 HALT LIFT TX CAN BUFFER OVERRUN 102/037 102/038 HALT HALT LIFT MAILBOX OVERRUN CPU HEARTBEAT NOT RECEIVED BY LIFT NODE Possible Cause/Recommended Action Job Card Possible causes: • There has been a transmit queue overrun. The transmit queue between the MCU and the DSP is full and the message dropped. • The TP1 connector on the Lift board is closed. Proceed as follows: Check whether a jumper exists on the TP1 connector on the Lift board. In this case you must remove the jumper from the TP1 connector on the Lift board. D/R A201 page 1161 If there is no jumper on the TP1 connector on the Lift board, the Lift board is faulty. Change the Lift board then perform a Lift Calibration. CAL A031 page 1687 The mailbox is overrun. The mailbox queue used in the inter-task communication in the MCU is full and the mails are dropped. D/R A201 page 1161 The Lift board is faulty. You must change the Lift board then perform a Lift Calibration. CAL A031 page 1687 There has been a heartbeat failure. The Gantry CPU did not send periodic "heartbeat" CAN message. D/R A190 page 1131 1. Change the Gantry CPU Board (see Job Card D/ CAL A029 R A190 - Gantry CPU Board on page 1131). page 2. Perform a Collimator Calibration (see Job Card 1683 CAL A029 - Collimator Format Calibration on page 1683). 3. Perform a Collimation Check (see Job Card ELE ELE A028 page 679 A028 - Collimation Checks on page 679). 102/039 DEBUG ONLY HEARTBEAT DISABLED ON LIFT NODE The Gantry CPU tried to disable the "heartbeat" check of the lift node. D/R A190 page 1131 1. Change the Gantry CPU Board (see Job Card D/ CAL A029 R A190 - Gantry CPU Board on page 1131). page 2. Perform a Collimator Calibration (see Job Card 1683 CAL A029 - Collimator Format Calibration on page 1683). 3. Perform a Collimation Check (see Job Card ELE ELE A028 page 679 A028 - Collimation Checks on page 679). 102/040 HALT LIFT INVALID PDO LENGTH The lift node receives a PDO with an invalid DLC. A1016 page 949 Refer to JC DIAG A1110 ROTATION CONTROL FAILURE on page 952 to fix the problem. Page no. 861 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 102/041 WARNING VALID LINE WAS ACTIVE ON LIFT NODE The valid motion line is active at power-up. 102/042 WARNING LIFT WAS STOPPED WITHOUT STOP COMMAND The lift node stopped the motion by itself because the button/pedal responsible for the motion was released and no stop order was received before the timeout. Job Card D/R A190 page 1131 1. Change the Gantry CPU Board (see Job Card D/ R A190 - Gantry CPU Board on page 1131). CAL A029 2. Perform a Collimator Calibration (see Job Card page CAL A029 - Collimator Format Calibration on 1683 page 1683). 3. Perform a Collimation Check (see Job Card ELE ELE A028 A028 - Collimation Checks on page 679). page 679 D/R A190 page 1131 CAL A029 page 1. Change the Gantry CPU Board (see Job Card D/ 1683 R A190 - Gantry CPU Board on page 1131). 2. Perform a Collimator Calibration (see Job Card ELE A028 CAL A029 - Collimator Format Calibration on page 679 page 1683). 3. Perform a Collimation Check (see Job Card ELE A028 - Collimation Checks on page 679). 102/043 DEBUG_O NLY LIFT INVALID BRAKE DEFECT ERROR There has been a brake malfunction. The Lift node normally does not report this error in any case. Ignore this error. If the problem persists, contact your OLC. 102/044 DEBUG_O NLY 102/045 HALT LIFT INVALID There has been a clutch malfunction. The Lift node CLUTCH MALnormally does not report this error in any case. FUNCTION ERROR Ignore this error. If the problem persists, contact your OLC. LIFT INVALID USER INTERFACE ERROR One of the Gantry footswitch pedals have failed. Press very slowly or very quickly on each Gantry footswitch pedals until the 102/045 error is triggered again to identify which pedal is defective. Replace the left and/or right faulty Gantry footswitch pedals. 102/046 Chapter 9 DEBUG_O NLY LIFT INVALID COLLIMATOR BUTTON ERROR There is a collimator button error. Ignore this error. If the problem persists, contact your OLC. Page no. 862 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 102/047 DEBUG_O NLY LIFT INVALID INITIALIZATION ERROR Possible Cause/Recommended Action Job Card There has been an initialization error. The Lift node normally does not report this error in any case. Ignore this error. If the problem persists, contact your OLC. 102/048 DEBUG_O NLY LIFT INVALID FORCE SENSOR DEFECT ERROR There has been a force sensor defect. The Lift node normally does not report this error in any case. Ignore this error. If the problem persists, contact your OLC. 102/049 DEBUG_O NLY LIFT INVALID FORCE SENSOR RANGE ERROR There has been a force sensor range error. The Lift node normally does not report this error in any case. Ignore this error. If the problem persists, contact your OLC. 102/050 HALT LIFT HBRIDGE VOLTAGE ERROR There has been an H-Bridge voltage error. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 102/051 HALT 102/052 DEBUG_O NLY 102/053 DEBUG_O NLY 103/001 ADVISORY LIFT UNEXPECTED There has been a software error. EVENT ERROR Reboot the system from the X-ray Console. If the problem persists, contact your OLC. LIFT INVALID GO ROTATION FAILURE ERROR Reboot the system from the X-ray Console. If the problem persists, contact your OLC. LIFT INVALID GO Reboot the system from the X-ray Console. If the ANGULATION FAIL- problem persists, contact your OLC. URE ERROR LCD: A06 Lift end position is reached On every “StartMotion” command, the IPMS checks whether the software stop limit for the specified direction is not already reached. If the limit is reached, the "StartMotion" command is ignored and the following error is returned: Lift “UpperLimitAlreadyReached” if the lift upper stop limit is active “LowerLimitAlreadyReached” if the lift lower stop limit is active Operator error. No service action is required. Page no. 863 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 103/002 ADVISORY LCD: A06 Lift end position is reached On every “StartMotion” command, the IPMS checks whether the software stop limit for the specified direction is not already reached. If the limit is reached, the "StartMotion" command is ignored and the following error is returned: Lift “UpperLimitAlreadyReached” if the lift upper stop limit is active “LowerLimitAlreadyReached” if the lift lower stop limit is active Job Card Operator error. No service action is required. Chapter 9 Page no. 864 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages 3-2 Error Codes from 110/yyy: Rotation Code Category Text in Log File or on LCD Possible Cause/Recommended Action 110/001 HALT ROTATION RELAY DEFECT There is a relay defect at power-up. A relay (on the rotation board) is mounted in parallel with the Hbridge of the motor. This relay, when shut, creates a short-cut of the H-bridge. At power-up, the node does the following: - injects 15 V to the H-Bridge - shuts the relay and checks that there is 0 V - re-opens the relay and checks that there is 15 V. If not, this signal is produced. 1. Reboot the system. Check the error logs to see whether the 110/001 ROTATION RELAY DEFECT error occurs within the same time as another POSITION ERROR (e.g. rotation or compression). 2. If a POSITION ERROR (e.g. rotation or compression) does exist within the same time, ignore the 110/001 ROTATION RELAY DEFECT error. Do not change the Rotation Board, and take appropriate action to resolve the POSITION ERROR. 3. If a POSITION ERROR (e.g. rotation or compression) does not exist within the same time, the 110/001ROTATION RELAY DEFECT error is valid. Change the Rotation Board and then recalibrate the Rotation Arm. 110/006 HALT ARM TURNED RIGHT TOO FAR Job Card D/R A221 page 1223 CAL A021 page 1679 The Arm is over the software specified limit for the farmost right position. Occurs when the Arm position is not between the software limits at power-up (including a tolerance to be defined). Typically, this can happen when Arm has been moved manually. Shut down the Gantry, move lift down manually and reboot the Gantry. 110/007 HALT ARM TURNED LEFT The Arm is over the software specified limit for the TOO FAR farmost left position. Occurs when the Arm position is not between the software limits at power-up (including a tolerance to be defined). Typically, this can happen when Arm has been moved manually. Shut down the Gantry, move lift up manually and reboot the Gantry. Page no. 865 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 111/001 DEBUG ONLY ROTATION SOFTWARE ERROR On every command sent by the PTB, the IPMS checks whether the command identifier is part of the list of commands to be taken into account by the IPMS. If the command is not recognized, it is ignored, and “CommandIdError” is returned. Job Card Should not occur in the field. It could be a disconnect between the CPU soft release and the Node soft release. If the problem persists, contact your OLC. 111/002 DEBUG ONLY ROTATION SOFTWARE ERROR On every command sent by the PTB, the IPMS checks whether all the parameter values are compatible with their corresponding range. If they are not compatible, the IPMS ignores the command and returns the “ParameterError” to the PTB. Should not occur in the field. It could be a disconnect between the CPU soft release and the Node soft release. If the problem persists, contact your OLC. 111/003 WARNING ROTATION CALIB NOT ACHIEVED 111/004 WARNING NO VALID LINE FOR ROTATION If the calibration has not been achieved, for each CAN message which is not a calibration command, the IPMS ignores the command and returns the “CalibrationNotAchieved” error. CAL A021 page 1679 Perform Job Card CAL A021 - Arm Rotation Calibration on page 1679. Occurs when the Gantry CPU requests a motion but node does not see the valid line. The valid line is an RT line that is activated by the CPLD of the node containing the UIF during the time when the UIF is pressed + a deceleration time. This activation is a frequency put on the RT line and that is specific to the button pressed (Tube Head and/or X-ray Console). Also occurs when the valid line falls before the end of the movement. This error does not concern decompression and tilt. DIAG A1116 page 954 Valid line problem. Check the different motions, using all keypads to determine the defective node then refer to JC DIAG A1116 ROTATION CONTROL FAILURE on page 954 for diagnostics. Chapter 9 Page no. 866 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 111/005 DEBUG ONLY ROTATION BUTTON NOT PRESSED Possible Cause/Recommended Action Job Card Rotation node does not execute the command because it has not seen on CAN a signal indicating that the corresponding Rotation button had been pressed. 1. Try other motions (lift for example). If "button not pressed" appears again, a CAN communication problem exists. 2. Otherwise, try same lift motion but by pressing other buttons than the initial one. - If "button not pressed" appears again, the faulty FRU is the Rotation board - If "button not pressed" appears only when the initial Rotation button is pressed, the faulty FRUs are the boards linked to the UIF that has been pressed for the motion. For example, Lift board, Compression board, or Tube Tilt board. 3. Rotation, Compression, or Tilt re-calibration is required following corresponding board replacement. 112/000 HALT ROTATION SOFTWARE ERROR The watch-dog receives a pulse from microcontroller every 40 ms. If not, it resets the microcontroller, and the rotation node restarts and sends a boot-up signal to Gantry CPU. The only possible reason for a bootup of a node after system power-up is a reset by watchdog. Therefore, when Gantry CPU receives the boot-up signal, it produces the SWOverRun error. This failure is linked to a firmware problem (microcontroller or CPLD) on the Rotation board. Change the Rotation board then perform a Rotation Calibration. 112/001 HALT ROTATION POTEN- There is a Potentiometer Defect TIOMET DEFECT Rotation node checks that the signal coming from the potentiometer is within an acceptable range. D/R A221 page 1223 CAL A021 page 1679 A1103 page 950 Refer to JC DIAG A1103 ROTATION CONTROL FAILURE on page 950 to fix the problem. 112/002 HALT ROTATION For every node equipped with a coding wheel. If a ENCODER DEFECT coding wheel defect detected through the complemented HW lines, the IPMS stops, and forbids the motion and sends an error message. The signal coming from motor encoder contains four phases. A, A complementary, B, B complementary. Node checks two things: complementarity + sequence of phases. A1104 page 950 Refer to JC DIAG A1104 ROTATION CONTROL FAILURE on page 950 to fix the problem. Page no. 867 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 112/004 N/A ROTATION MOTION UNCOHERENT Occurs when pulses are sent by the coder whereas the IPMS considers that there must not be any motion. This check concerns the Lift, Rotation, Compression, and Tilt nodes. Job Card Reset the system from the X-ray Console. If the problem persists call your OLC. 112/005 HALT ROTATION CORRE- Occurs when signals from absolute coder (potentiLATION ERROR ometer) and coding wheel (motor encoder) are not correlated. A1107 page 951 Refer to JC DIAG A1107 ROTATION CONTROL FAILURE on page 951 to fix the problem. 112/008 HALT ROTATION BRAKE DEFECT Occurs when the Arm rotation brake has no current or less than 1.5 A running through it. The brake current is continuously measured, and this alarm is raised if the brake: - is released and there is not enough current through it - is operating and there is too much current in it A1112 page 953 Refer to JC DIAG A1112 ROTATION BRAKE DEFECT on page 953 to fix the problem. 112/010 HALT ROTATION HARDWARE LIMIT REACHED Occurs when the IPMS detects that a motion has reached the electrical stop limit. In this case the IPMS stops and forbids the motion and sends an error message. A1109 page 951 Refer to JC DIAG A1109 ROTATION CONTROL FAILURE on page 951 to fix the problem. 112/011 112/012 HALT WARNING ROTATION OVERSPEED ROTATION LOW SPEED Occurs when the speed measured by encoder goes too high as regard to the speed profile (and correlation is OK). A1113 page 953 1. First, refer to JC DIAG A1113 ROTATION CONTROL FAILURE on page 953. 2. If the problem persists, check rotation mechanism, if greasing required, refer to Job Card PM A205 - Mechanical checks and lubrication on page 1779. PM A205 page 1779 The rotation speed measured by the encoder is too low in relation to the speed profile (and correlation is OK). A1114 page 953 Refer to JC DIAG A1114 ROTATION CONTROL FAILURE on page 953 to fix the problem. Chapter 9 Page no. 868 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action Job Card 112/014 HALT ROTATION OVERCURRENT Occurs when an integrated value of the current is too high, that is when the current is too high during too much time. A1110 page 952 Refer to JC DIAG A1110 ROTATION CONTROL FAILURE on page 952 to fix the problem. 112/015 DEBUG ONLY ROTATION SOFTWARE ERROR Occurs when the node is currently performing a movement and the Gantry CPU sends a command for another movement while the current movement is not finished. This is a CPU problem because CPU did not detect the current movement. Should not occur in the field. It could be a disconnect between the CPU soft release and the Node soft release. If the problem persists, contact your OLC. 112/016 HALT ROTATION NODE Occurs when the hardware configuration (CPLD) of FW INCOMPATIBIL- the rotation node, the DSP, or the MCU firmware not ITY match. Change the Rotation board then perform a Rotation Calibration. 112/017 HALT ROTATION NODE PARITY ERROR Occurs when the parity bit does not set correctly on the on-board bus between the CPLD and the MCU D/R A221 page 1223 CAL A021 page 1679 D/R A221 page 1223 Change the Rotation board then perform Rotation Calibration. CAL A021 page 1679 112/018 N/A STOP LINE WAS ACTIVATED BECAUSE OF UNCONTROLLED MOTION An uncontrolled motion is detected by the DSP. The rotation node sends this error and activates the MCU_STOP_MOTION line which leads to 0x500A error. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 112/019 N/A STOP LINE WAS ACTIVATED BY CPU The stop motion line is active. The main CPU detected an error and activated the stop motion line or did not deactivate it at all. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. Page no. 869 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action Job Card 112/020 HALT LOW VOLTAGE ERROR ON ROTATION NODE There is a low voltage error. Occurs if the voltage of the power supply to the rotation board falls below 24 V. D/R A221 page 1223 Change the Rotation board then perform Rotation Calibration. CAL A021 page 1679 There is a read timeout error. Occurs if the MCU does not react within 15 ms of receiving an interrupt request (IRQ) coming from the CPLD. D/R A221 page 1223 Change the Rotation board then perform Rotation Calibration. CAL A021 page 1679 There is a CPLD memory error. Test data from the CPLD is periodically read to ensure the proper communication. If this error does not match the node sends this error. D/R A221 page 1223 112/021 112/022 112/023 HALT HALT HALT ROTATION READ TIMEOUT ERROR ROTATION CPLD MEMORY ERROR UNCONTROLLED ROTATION MOTION DETECTED. STOP LINE ACTIVATED Change the Rotation board then perform Rotation Calibration. CAL A021 page 1679 There is uncontrolled motion. If the motion is performed when the rotation node is not supposed to drive it, the rotation node sends this error, and activates the MCU_STOP_MOTION line which leads to 0x500A error. D/R A230 page 1251 Change the rotation gas spring (Job Card D/R A230 - Rotation Gas Spring on page 1251). 112/024 HALT ROTATION RELATIVE ENCODER ERROR There is a relative encoder error. Occurs when the signal coming from the relative encoder does not evolve during the rotation motion while the signal coming from the absolute encoder does. D/R A228 page 1243 Change the Rotation Motor + Encoder + Cables W205 and W302 (see Job Card D/R A228 - Rotation Motor on page 1243). Chapter 9 Page no. 870 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 112/025 HALT ROTATION ABSOLUTE ENCODER ERROR The Rotation Potentiometer (absolute encoder) signal is too noisy. The change in the Rotation Potentiomter voltage is significantly higher than expected during normal motion for a period of at least 20 ms. Job Card 1. Check all cables are firmly connected on the Rotation Board, and pass around the sides of the Rotation Board. Ensure none of the cables pass over the Rotation Board as this may lead to EMC D/R A227 interference, and suprious error messages. page 2. Ensure that the 6 mounting screws on the Rota1239 tion Board are securely fastened so that the Rotation Board is properly grounded. 3. Check the cabling and cable connection between the Rotation Board and the Rotation Potentiome- D/R A221 page ter. 1223 4. If the problem persists, the issue is not bad cabling or bad earthing. Change the Rotation Potentiometer then perform Rotation Calibration. CAL A021 5. If the problem persists, change the Rotation page Board then perform Rotation Calibration. 1679 112/026 112/027 WARNING WARNING 112/028 HALT ROTATION MCU CALIBRATION DATA CORRUPT ROTATION DSP CALIBRATION DATA CORRUPT ROTATION MCU EEPROM FAILURE The MCU calibration data is corrupt. The checksum on the calibration data stored by the MCU does not match. CAL 021 page 1679 Perform a rotation calibration. If the problem persists, change the rotation board. D/R A221 page 1223 The DSP calibration data is corrupt. The checksum on the calibration data stored by the DSP does not match. CAL 021 page 1679 Perform a rotation calibration. If the problem persists, check the rotation cabling, change the rotation board. D/R A221 page 1223 There is an MCU EEPROM failure. The readback on the newly written data to the EEPROM has failed. D/R A221 page 1223 Change the Rotation board then perform a Rotation Calibration. 112/029 WARNING ROTATION POSITION ERROR The rotation motion did not stop at the target/limit position and went further than the allowed margin. CAL 021 page 1679 A1115 page 954 Refer to JC DIAG A1115 ROTATION POSITION OVERSHOOT/ROTATION CONTROL FAILURE on page 954 to fix the problem. Page no. 871 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 112/030 WARNING ROTATION DECEL- The rotation motion began to slow down but did not ERATION ERROR stop before the allowed time. Job Card A1115 page 954 Refer to JC DIAG A1115 ROTATION POSITION OVERSHOOT/ROTATION CONTROL FAILURE on page 954 to fix the problem. 112/031 HALT ROTATION MOTION STARTED IN REVERSE DIRECTION The rotation motion was about to go in the reverse direction to the direction that was requested. Change the Rotation board then perform a Rotation Calibration. D/R A221 page 1223 CAL 021 page 1679 112/032 HALT ROTATION DSP TIMEOUT The DSP did not answer to the MCU before the time- D/R A221 page out. 1223 Change the Rotation board then perform a Rotation CAL 021 Calibration. page 1679 112/033 WARNING ROTATION CAN COMMAND NOT PROCESSED The CAN command was not processed. The main CPU have sent command to the rotation node before the rotation node could acknowledge the previous command. Reboot the system from the X-ray Console. Retry the command. If the problem persists, contact your OLC. 112/034 HALT ROTATION RX CAN Possible causes: BUFFER OVERRUN • CAN overrun. The input queue of the incoming CAN messages of the MCU is full and message dropped. • The TP1 connector on the Rotation board is closed. Proceed as follows: Check whether a jumper exists on the TP1 connector on the Rotation board. In this case you must remove the jumper from the TP1 connector on the Rotation board. If there is no jumper on the TP1 connector on the Rotation board, reboot the complete system. If the problem persists, check the other nodes (other than rotation). If the other nodes are OK, check the rotation node (cabling, potentiometer, board). Chapter 9 Page no. 872 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category 112/035 HALT Text in Log File or on LCD Possible Cause/Recommended Action ROTATION TX CAN The transmit queue between the MCU and the DSP BUFFER OVERRUN is full and message dropped. Change the Rotation board then perform a Rotation Calibration. 112/036 HALT ROTATION MAILBOX OVERRUN The mailbox queue used in the inter-task communication in the MCU is full and mails dropped. Change the Rotation board then perform a Rotation Calibration. 112/037 HALT CPU HEARTBEAT NOT RECEIVED BY ROTATION NODE There has been a heartbeat failure. The Gantry CPU did not send periodic "heartbeat" CAN message. Job Card D/R A221 page 1223 CAL 021 page 1679 D/R A221 page 1223 CAL 021 page 1679 D/R A190 page 1131 1. Change the Gantry CPU Board (see Job Card D/ CAL A029 R A190 - Gantry CPU Board on page 1131). page 2. Perform a Collimator Calibration (see Job Card 1683 CAL A029 - Collimator Format Calibration on page 1683). 3. Perform a Collimation Check (see Job Card ELE ELE A028 page 679 A028 - Collimation Checks on page 679). 112/038 DEBUG ONLY HEARTBEAT DISABLED ON ROTATION NODE The Gantry CPU tried to disable the "heartbeat" check of the rotation node. D/R A190 page 1131 1. Change the Gantry CPU Board (see Job Card D/ CAL A029 R A190 - Gantry CPU Board on page 1131). page 2. Perform a Collimator Calibration (see Job Card 1683 CAL A029 - Collimator Format Calibration on page 1683). 3. Perform a Collimation Check (see Job Card ELE ELE A028 page 679 A028 - Collimation Checks on page 679). 112/039 HALT ROTATION INVALID The rotation node receives a PDO with an invalid PDO LENGTH DLC. A1117 page 955 Refer to JC DIAG A1117 ROTATION COMMUNICATION FAILURE on page 955 to fix the problem. Page no. 873 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 112/040 WARNING VALID LINE WAS ACTIVE ON ROTATION NODE 112/041 WARNING ROTATION WAS STOPPED WITHOUT STOP COMMAND Possible Cause/Recommended Action Job Card D/R A190 page 1131 1. Change the Gantry CPU Board (see Job Card D/ R A190 - Gantry CPU Board on page 1131). CAL A029 2. Perform a Collimator Calibration (see Job Card page CAL A029 - Collimator Format Calibration on 1683 page 1683). 3. Perform a Collimation Check (see Job Card ELE ELE A028 A028 - Collimation Checks on page 679). page 679 The valid motion line is active at power-up. The rotation node stopped the motion by itself because the button/pedal responsible for the motion was released and no stop order was received before the timeout. D/R A190 page 1131 CAL A029 page 1. Change the Gantry CPU Board (see Job Card D/ 1683 R A190 - Gantry CPU Board on page 1131). 2. Perform a Collimator Calibration (see Job Card ELE A028 CAL A029 - Collimator Format Calibration on page 679 page 1683). 3. Perform a Collimation Check (see Job Card ELE A028 - Collimation Checks on page 679). 112/042 WARNING ROTATION NODE The rotation node failed to switch to angulation SWITCH TO ANGU- mode. LATION MODE FAILED Check the clutch position. If the clutch is not in angulation mode (detector is locked), check the clutch control, change the clutch device (after clutch control check). 112/043 WARNING ROTATION NODE The rotation node failed to switch to rotation mode. SWITCH TO ROTATION MODE FAILED Check the clutch position. If the clutch is still in angulation mode (detector is free), check the clutch control, change the clutch device (after clutch control check). 112/044 WARNING ANGULATION CLUTCH NOT READY At power-up, the rotation node checks that there is no current through the clutch. This error occurs if: • the operator requires several angulations in less than 300 msec • at power on there is no current into the clutch • clutch stays locked to the detector on angulation request, check clutch operation at several angles (45° to 90°). A1111 page 952 Refer to JC DIAG A1111 ROTATION CLUTCH FAILURE on page 952 to fix the problem. Chapter 9 Page no. 874 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category 112/045 HALT Text in Log File or on LCD Possible Cause/Recommended Action ROTATION OPTI- At power-up, the rotation node shuts down the LED CAL FORK DEFECT of the left optical fork, and checks that the photoresistor shuts down. The optical forks are hardware limits hence they are never obstructed. Job Card A1118 page 955 Refer to JC DIAG A1118 ROTATION CONTROL FAILURE on page 955 to fix the problem. 112/046 DEBUG ONLY ROTATION INVALID Ignore this error. If the problem persists, contact your USER INTERFACE OLC. ERROR 112/047 DEBUG ONLY ROTATION INVALID Ignore this error. If the problem persists, contact your LIFT UP SLOW OLC. BUTTON ERROR 112/048 DEBUG ONLY ROTATION INVALID Ignore this error. If the problem persists, contact your UP FAST BUTTON OLC. ERROR 112/049 DEBUG ONLY ROTATION INVALID Ignore this error. If the problem persists, contact your LIFT DOWN SLOW OLC. ERROR 112/050 DEBUG ONLY ROTATION INVALID Ignore this error. If the problem persists, contact your LIFT DOWN FAST OLC. BUTTON ERROR 112/051 DEBUG ONLY ROTATION INVALID Ignore this error. If the problem persists, contact your ROT LEFT SLOW OLC. BUTTON ERROR 112/052 DEBUG ONLY ROTATION INVALID Ignore this error. If the problem persists, contact your ROT LEFT FAST OLC. BUTTON ERROR 112/053 DEBUG ONLY ROTATION INVALID Ignore this error. If the problem persists, contact your ROT RIGHT SLOW OLC. BUTTON ERROR 112/054 DEBUG ONLY ROTATION INVALID Ignore this error. If the problem persists, contact your ROT RIGHT FAST OLC. BUTTON ERROR 112/055 DEBUG ONLY ROTATION INVALID Ignore this error. If the problem persists, contact your MLO LEFT BUTOLC. TON ERROR 112/056 DEBUG ONLY ROTATION INVALID Ignore this error. If the problem persists, contact your MLO RIGHT BUT- OLC. TON ERROR 112/057 DEBUG ONLY ROTATION INVALID Ignore this error. If the problem persists, contact your CC BUTTON OLC. ERROR 112/058 DEBUG ONLY ROTATION INVALID Ignore this error. If the problem persists, contact your COLLIMATOR BUT- OLC. TON ERROR Page no. 875 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category 112/059 DEBUG ONLY ROTATION INVALID Ignore this error. If the problem persists, contact your INITIALIZATION OLC. ERROR 112/060 DEBUG ONLY ROTATION INVALID Ignore this error. If the problem persists, contact your STEP LOST ERROR OLC. 112/061 DEBUG ONLY ROTATION INVALID Ignore this error. If the problem persists, contact your FORCE SENSOR OLC. DEFECT 112/062 DEBUG ONLY ROTATION INVALID Ignore this error. If the problem persists, contact your COMMAND ERROR OLC. 112/063 DEBUG ONLY ROTATION INVALID Ignore this error. If the problem persists, contact your FORCE SENSOR OLC. RANGE ERROR 112/064 HALT ROTATION INVALID Reboot the system from the X-ray Console. If the SW ERROR problem persists, contact your OLC. 112/065 HALT ROTATION INVALID Reboot the system from the X-ray Console. If the problem persists, contact your OLC. INTERNAL SW ERROR 112/066 DEBUG ONLY ROTATION INVALID The lift down pedal is depressed. LIFT DOWN PEDAL PRESS ERROR Ignore this error. If the problem persists, contact your OLC. 112/067 DEBUG ONLY ROTATION INVALID The lift up pedal is depressed. LIFT UP PEDAL PRESS ERROR Ignore this error. If the problem persists, contact your OLC. 112/068 DEBUG ONLY ROTATION INVALID The compression pedal is depressed. COMPRESSION Ignore this error. If the problem persists, contact your PEDAL PRESS OLC. ERROR 112/069 DEBUG ONLY ROTATION INVALID The Lift Up button on either the Compression Arm or DECOMPRESSION the Tube Head is depressed. PEDAL PRESS Ignore this error. If the problem persists, contact your ERROR OLC. 112/070 DEBUG ONLY ROTATION INVALID The Lift Up button on either the Compression Arm or the Tube Head is depressed. LIFT UP SLOW BUTTON PRESS Ignore this error. If the problem persists, contact your ERROR OLC. 112/071 DEBUG ONLY ROTATION INVALID The Down Lift button on either the Compression Arm LIFT UP FAST BUT- or the Tube Head is depressed. TON PRESS Ignore this error. If the problem persists, contact your ERROR OLC. Chapter 9 Text in Log File or on LCD Possible Cause/Recommended Action Job Card Page no. 876 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 112/072 DEBUG ONLY ROTATION INVALID The Down Lift button on either the Compression Arm LIFT DOWN SLOW or the Tube Head is depressed. BUTTON ERROR Ignore this error. If the problem persists, contact your OLC. 112/073 DEBUG ONLY ROTATION INVALID The Left Rotation button on either the Compression LIFT DOWN FAST Arm or the Tube Head is depressed. BUTTON PRESS Ignore this error. If the problem persists, contact your ERROR OLC. 112/074 DEBUG ONLY ROTATION INVALID The Left Rotation button on either the Compression ROT LEFT SLOW Arm or the Tube Head is depressed. BUTTON PRESS Ignore this error. If the problem persists, contact your ERROR OLC. 112/075 DEBUG ONLY ROTATION INVALID The Left Rotation button on either the Compression Arm or the Tube Head is depressed. ROT LEFT FAST BUTTON PRESS Ignore this error. If the problem persists, contact your ERROR OLC. 112/076 DEBUG ONLY ROTATION INVALID The Right Rotation button on either the Compression ROT RIGHT SLOW Arm or the Tube Head is depressed. BUTTON PRESS Ignore this error. If the problem persists, contact your ERROR OLC. 112/077 DEBUG ONLY ROTATION INVALID The Right Rotation button on either the Compression ROT RIGHT FAST Arm or the Tube Head is depressed. BUTTON PRESS Ignore this error. If the problem persists, contact your ERROR OLC. 112/078 DEBUG ONLY ROTATION INVALID The MLO Left button on either the Compression Arm or the Tube Head is depressed. MLO LEFT BUTTON PRESS Ignore this error. If the problem persists, contact your ERROR OLC. 112/079 DEBUG ONLY ROTATION INVALID The MLO Right button on either the Compression MLO RIGHT BUT- Arm or the Tube Head is depressed. TON PRESS Ignore this error. If the problem persists, contact your ERROR OLC. 112/080 DEBUG ONLY ROTATION INVALID The CC button on either the Compression Arm or the CC BUTTON Tube Head is depressed. PRESS ERROR Ignore this error. If the problem persists, contact your OLC. Page no. 877 ERR-SUB-A-003.fm Job Card Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category 112/081 DEBUG ONLY Text in Log File or on LCD Possible Cause/Recommended Action Job Card ROTATION INVALID Ignore this error. If the problem persists, contact your COLLIMATOR BUT- OLC. TON PRESS ERROR 113/001 ADVISORY LCD: A15 Rotation end position is reached 113/002 ADVISORY LCD: A15 Rotation end position is reached 113/003 ADVISORY LCD: A22 Angulation limit is reached 113/004 ADVISORY LCD: A22 Angulation limit is reached On every “StartMotion” command, the IPMS checks whether the software stop limit for the specified direction is not already reached. If the limit is reached, command is ignored and the following error is returned: Rotation “UpperLimitAlreadyReached” if the image receptor +180° software stop limit is active “LowerLimitAlreadyReached” if the image receptor – 180° software stop limit is active Angulation “UpperLimitAlreadyReached” if the arm +45° software stop limit is active “LowerLimitAlreadyReached” if the arm –45° software stop limit is active Operator error. No service action required. Chapter 9 Page no. 878 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages 3-3 Error Codes from 120/yyy: Compression Code Category Text in Log File or on LCD Possible Cause/Recommended Action 120/001 WARNING LIFT UP BUTTON STILL PRESSED 120/002 WARNING LIFT UP BUTTON STILL PRESSED 120/003 WARNING LIFT DOWN BUTTON STILL PRESSED 120/004 WARNING LIFT DOWN BUTTON STILL PRESSED 120/005 WARNING ROTATION BUTTON STILL PRESSED UIF Still Pressed [i] (for i =1 - 11) = Occurs when one of the 11 buttons on compression node is still pressed: - Lift up (V1, V2) - Lift down (V1, V2) - Rotation Right (V1, V2) - Rotation Left (V1, V2) - Preset CC - Preset +MLO - Preset -MLO [i] indicates the nature of the button. Right or left is not indicated. 120/006 WARNING ROTATION BUTTON STILL PRESSED 120/007 WARNING ROTATION BUTTON STILL PRESSED 120/008 WARNING ROTATION BUTTON STILL PRESSED 120/009 WARNING CC BUTTON STILL PRESSED 120/010 WARNING +MLO BUTTON STILL PRESSED 120/011 WARNING -MLO BUTTON STILL PRESSED 121/001 DEBUG ONLY COMPRESSION SOFTWARE ERROR See JC DIAG A1201 KEYPAD FAILURE on page 956 to fix the problem. A1201 page 956 On every command sent by the PTB, the IPMS checks whether the command identifier is part of the list of commands to be taken into account by IPMS. If the command is not recognized, it is ignored, and “CommandIdError” is returned to the PTB. D/R A250 page 1323 1. Change the Compression Board. 2. Perform a calibration of the Compression Force Sensor. 3. Perform a Compression Thickness calibration. Page no. 879 ERR-SUB-A-003.fm Job Card CAL A048 page 1709 CAL A050 page 1721 Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action Job Card 121/002 DEBUG ONLY COMPRESSION SOFTWARE ERROR On every command sent by the PTB, the IPMS checks whether all parameter values are compatible with their corresponding range. If they are not within their corresponding range, the command is ignored, and “ParameterError” is returned to the PTB. D/R A250 page 1323 1. Change the Compression Board. 2. Perform a calibration of the Compression Force Sensor. 3. Perform a Compression Thickness calibration. CAL A048 page 1709 CAL A050 page 1721 121/003 WARNING COMPRESSION CALIB NOT ACHIEVED If the calibration is not achieved, for each CAN mes- CAL A048 page sage which is not a calibration command, the IPMS 1709 ignores the command and sends the “CalibrationNotAchieved” error. CAL A050 page 1. Perform a calibration of the Compression Force 1721 Sensor. 2. Perform a Compression Thickness calibration. 121/004 WARNING NO VALID LINE FOR COMPR There is no valid Line. The Gantry CPU requests a motion but node does not see the valid line. The valid line is an RT line that is activated by the CPLD of the node containing the UIF during the time when the UIF is pressed + a deceleration time. This activation is a frequency put on the RT line and that is specific to the button pressed. This also occurs when the valid line falls before the end of the movement. This error does not concern decompression and tilt. A1215 page 962 Check the different motions, using all keypads to determine the defective node. Then refer to JC DIAG A1215 COMPRESSION CONTROL FAILURE on page 962 to fix the problem. 121/005 DEBUG ONLY COMPR BUTTON NOT PRESSED Occurs when the CPU sends a "Start Motion" to the node, whereas no previous command on CAN towards the CPU was read by the node before. This error completes the No Valid Line error because it avoids problems due to simultaneous motions. 1. Change the Compression Board. 2. Perform a calibration of the Compression Force Sensor. 3. Perform a Compression Thickness calibration. Chapter 9 D/R A250 page 1323 CAL A048 page 1709 CAL A050 page 1721 Page no. 880 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action Job Card 122/001 HALT COMPRESSION SOFTWARE ERROR The watch-dog receives a pulse from microcontroller every 40 ms. If not, it resets the microcontroller, node restarts and sends a boot-up signal to Gantry CPU. The only possible reason for a boot-up of a node after system power-up is a reset by watchdog. Therefore, when Gantry CPU receives the boot-up signal, it produces the SWOverRun error. D/R A250 page 1323 CAL A048 page 1709 1. Change the Compression Board (Firmware prob- CAL A050 page lem: microcontroller or clock CPLD issue). 1721 2. Perform a calibration of the Compression Force Sensor. 3. Perform a Compression Thickness calibration. 122/002 HALT COMPR POTENTIOMETER DEFECT There is a potentiometer defect. At all time, the node checks that the signal coming from potentiometer is within an acceptable range. If not, it sends this signal. A1214 page 961 See JC DIAG A1214 COMPRESSION CONTROL FAILURE on page 961 to fix the problem. 122/003 HALT COMPRESSION For every node equipped with a coding wheel. If a ENCODER DEFECT coding wheel defect is detected through the complemented HW lines, the IPMS stops, and forbids the motion, and sends an error message. The signal coming from motor encoder contains four phases. A, A complementary, B, B complementary. Node checks two things: complementarity + sequence of phases. A1203 page 957 See JC DIAG A1203 COMPRESSION CONTROL FAILURE on page 957 to fix the problem. 122/004 N/A COMP MOTION UNCOHERENT The IPMS sends a CAN message to ask a stop motion to system (message IPMS_SRS_ERR_023). On every node except compression, this check is performed on relative and absolute coders. On the compression node, only the relative coder is checked due to the manual compression ability. (Occurs when pulses are sent by the coder whereas the IPMS considers that there must not be any motion. This check concerns Lift, Rotation, Compression, and Tilt). A1203 page 957 See JC DIAG A1203 COMPRESSION CONTROL FAILURE on page 957 to fix the problem. Page no. 881 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category 122/005 HALT Text in Log File or on LCD Possible Cause/Recommended Action COMPR CORRELA- The is a Correlation Error. In case signals from absoTION ERROR lute coder (potentiometer) and coding wheel (motor encoder) are not correlated. Job Card A1205 page 957 See JC DIAG A1205 COMPRESSION CONTROL FAILURE on page 957 to fix the problem. 122/006 HALT COMPRESSION MOTOR STEP LOST Occurs when a difference is detected between the number of steps commanded and the number of steps detected by absolute encoder. This can happen whereas correlation is OK, for example when a mechanical hardpoint imposes zero signal from both encoder and potentiometer. A1206 page 958 See JC DIAG A1206 COMPRESSION CONTROL FAILURE on page 958 to fix the problem. 122/007 HALT COMPRESSIONOVERSPEED The compression speed measured by the encoder is too high in relation to the speed profile (and correlation is OK). A1206 page 958 See JC DIAG A1206 COMPRESSION CONTROL FAILURE on page 958 to fix the problem. 122/008 HALT COMPRESSION OVERCURRENT Occurs when an integrated value of the current is too high, that is when the current is too high during too much time. A1208 page 960 See JC DIAG A1208 COMPRESSION CONTROL FAILURE on page 960 to fix the problem. Chapter 9 Page no. 882 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 122/009 HALT LIFT UP BUTTON STILL PRESSED 122/010 HALT LIFT UP BUTTON STILL PRESSED 122/011 HALT LIFT DOWN BUTTON STILL PRESSED 122/012 HALT LIFT DOWN BUTTON STILL PRESSED 122/013 HALT ROTATION BUTTON STILL PRESSED SwitchDefect [i] (for i = 1 - 11) occurs when the two signals from the button do not arrive at the same time on the CPLD. The error signal indicates the nature of the button but not the side right or left. - Lift up (V1, V2) - Lift down (V1, V2) - Rotation Right (V1, V2) - Rotation Left (V1, V2) - Preset CC - Preset +MLO - Preset -MLO 122/014 HALT ROTATION BUTTON STILL PRESSED 122/015 HALT ROTATION BUTTON STILL PRESSED 122/016 HALT ROTATION BUTTON STILL PRESSED 122/017 HALT CC BUTTON STILL PRESSED 122/018 HALT +MLO BUTTON STILL PRESSED 122/019 HALT -MLO BUTTON STILL PRESSED 122/020 HALT COMPR BRAKES LOW CURRENT Job Card A1201 page 956 See JC DIAG A1201 KEYPAD FAILURE on page 956 to fix the problem. There is low brake current. Screwbrake brakes when no current in it. Manual compression brake brakes when supplied with current. The two brakes are supplied from the same point and one of them brakes at least all the time. In case the current that goes to the two brakes falls below an acceptable limit, this signal is sent. A1212 page 960 See JC DIAG A1212 COMPRESSION BRAKE FAILURE on page 960 to fix the problem. Page no. 883 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action Job Card 122/021 HALT COMPR FORCE SENSOR DEFECT Force has gone out of the acceptance range for the compression force sensor. A1217 page 962 Compression force out of range, refer to JC DIAG A1217 COMPRESSION CONTROL FAILURE on page 962. This error can be due to a too high reverse force applied on the paddle. If the reverse force is too sensitive, the Faulty FRU is the Compression trolley kit. 122/022 N/A EMERGENCY STOP MOTION Somebody presses the Emergency stop button. Then the compression node cuts the stop motion line and all nodes see it. Moreover, the compression board sends this signal to Gantry CPU. 1. Change the Compression Board. 2. Perform a calibration of the Compression Force Sensor. 3. Perform a Compression Thickness calibration. 122/024 DEBUG ONLY COMPR SOFTWARE ERROR D/R A250 page 1323 CAL A048 page 1709 CAL A050 page 1721 Occurs when the compression node is currently performing a movement and the Gantry CPU sends a command for another movement while the current movement is not finished. This is a CPU problem because the CPU did not detect the current movement. Ignore this error. If the problem persists, contact your OLC. 122/025 Chapter 9 HALT COMPRESSION NODE FW INCOMPATIBILITY Occurs when the hardware configuration (CPLD) of the node or the DSP or the MCU firmware not match. D/R A250 page 1323 1. Change the Compression Board. 2. Perform a calibration of the Compression Force Sensor. 3. Perform a Compression Thickness calibration. CAL A048 page 1709 CAL A050 page 1721 Page no. 884 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action Job Card 122/026 HALT COMPRESSION NODE PARITY ERROR Occurs when the parity bit does not set correctly on the on-board bus between the CPLD and the MCU. D/R A250 page 1323 1. Change the Compression Board. 2. Perform a calibration of the Compression Force Sensor. 3. Perform a Compression Thickness calibration. CAL A048 page 1709 CAL A050 page 1721 122/027 N/A STOP LINE WAS ACTIVATED BY CPU The main CPU detected an error and activated the stop motion line or did not deactivated it at all. Ignore this error. If the problem persists, contact your OLC. 122/028 122/029 HALT HALT LOW VOLTAGE ERROR ON COMPRESSION NODE COMPRESSION READ TIMEOUT ERROR If the voltage of the power supply falls below 24 V the node sends this error. D/R A250 page 1323 1. Change the Compression Board. 2. Perform a calibration of the Compression Force Sensor. 3. Perform a Compression Thickness calibration. CAL A048 page 1709 If the MCU does not react on the IRQ coming from the CPLD before 15 ms, the node sends this error. D/R A250 page 1323 1. Change the Compression Board. 2. Perform a calibration of the Compression Force Sensor. 3. Perform a Compression Thickness calibration. CAL A050 page 1721 CAL A048 page 1709 CAL A050 page 1721 122/030 HALT COMPRESSION CPLD MEMORY ERROR Test data from the CPLD is periodically read to ensure the proper communication. If this error does not match the node sends this error. D/R A250 page 1323 1. Change the Compression Board. 2. Perform a calibration of the Compression Force Sensor. 3. Perform a Compression Thickness calibration. CAL A048 page 1709 Page no. 885 ERR-SUB-A-003.fm CAL A050 page 1721 Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 122/031 HALT COMPRESSION RELATIVE ENCODER ERROR Possible Cause/Recommended Action The signal coming from the relative encoder does not evolves during the motion while the signal coming from the absolute encoder does. Job Card D/R A244 page 1297 Change the Compression Motor + Encoder + Cables (see Job Card D/R A244 - Compression Motor with Encoder and Compression Belt on page 1297). 122/033 HALT COMRPESSION COMMAND SEQUENCE IS INCORRECT There is a signal command error. The sequence of the signals to start the motor is wrong. 1. Change the Compression Board. 2. Perform a calibration of the Compression Force Sensor. 3. Perform a Compression Thickness calibration. D/R A250 page 1323 CAL A048 page 1709 CAL A050 page 1721 122/034 WARNING COMPRESSION MCU CALIBRATION DATA CORRUPT The MCU calibration data is corrupt. The checksum on the calibration data stored by the MCU does not match. 1. Perform a calibration of the Compression Force Sensor. 2. Perform a Compression Thickness calibration. 3. If the problem persists, check the Compression board cabling. 4. If the problem persists, change the Compression board. 122/035 HALT COMPRESSION MCU EEPROM FAILURE There is an MCU EEPROM failure. The readback on the newly written data to the EEPROM is failed. 1. Change the Compression Board. 2. Perform a calibration of the Compression Force Sensor. 3. Perform a Compression Thickness calibration. CAL A048 page 1709 CAL A050 page 1721 D/R A250 page 1323 D/R A250 page 1323 CAL A048 page 1709 CAL A050 page 1721 122/036 WARNING COMPRESSION CAN COMMAND NOT PROCESSED The main CPU have sent command to the compression node before the compression node could acknowledge the previous command. Reboot the system from the X-ray Console. Retry the command. If the problem persists, contact your OLC. Chapter 9 Page no. 886 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 122/037 HALT COMPRESSION CAN BUFFER OVERRUN Possible Cause/Recommended Action Job Card The input queue of the incoming CAN messages of the MCU is full and message dropped. Reboot the complete system. If the problem persists, check the other nodes (not compression). If other nodes are good, check the compression node (cabling and board). 122/038 HALT COMPRESSION MAILBOX OVERRUN The mailbox queue used in the inter-task communication in the MCU is full and mails dropped. 1. Change the Compression Board. 2. Perform a calibration of the Compression Force Sensor. 3. Perform a Compression Thickness calibration. D/R A250 page 1323 CAL A048 page 1709 CAL A050 page 1721 122/000 122/039 HALT DEBUG ONLY CPU HEARTBEAT NOT RECEIVED BY COMPRESSION NODE HEARTBEAT DISABLED ON COMPRESSION NODE There is a heartbeat failure. The main CPU did not send periodic "heartbeat" CAN message. D/R A190 page 1131 1. Change the Gantry CPU Board (see Job Card D/ CAL A029 R A190 - Gantry CPU Board on page 1131). page 2. Perform a Collimator Calibration (see Job Card 1683 CAL A029 - Collimator Format Calibration on page 1683). 3. Perform a Collimation Check (see Job Card ELE ELE A028 page 679 A028 - Collimation Checks on page 679). The main CPU tried to disable the "heartbeat" check of the compression node. D/R A190 page 1131 1. Change the Gantry CPU Board (see Job Card D/ CAL A029 R A190 - Gantry CPU Board on page 1131). page 2. Perform a Collimator Calibration (see Job Card 1683 CAL A029 - Collimator Format Calibration on page 1683). 3. Perform a Collimation Check (see Job Card ELE ELE A028 page 679 A028 - Collimation Checks on page 679). 122/040 HALT COMPRESSION INVALID PDO LENGTH A1216 page 962 Page no. 887 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 122/041 WARNING VALID LINE WAS ACTIVE ON COMPRESSION NODE 122/042 WARNING COMPRESSION WAS STOPPED WITHOUT STOP COMMAND Possible Cause/Recommended Action Job Card D/R A190 page 1131 1. Change the Gantry CPU Board (see Job Card D/ R A190 - Gantry CPU Board on page 1131). CAL A029 2. Perform a Collimator Calibration (see Job Card page CAL A029 - Collimator Format Calibration on 1683 page 1683). 3. Perform a Collimation Check (see Job Card ELE ELE A028 A028 - Collimation Checks on page 679). page 679 The valid motion line is active at power-up. The compression node stopped the motion by itself because the button/pedal responsible for the motion was released and no stop order was received before the timeout. D/R A190 page 1131 CAL A029 page 1. Change the Gantry CPU Board (see Job Card D/ 1683 R A190 - Gantry CPU Board on page 1131). 2. Perform a Collimator Calibration (see Job Card ELE A028 CAL A029 - Collimator Format Calibration on page 679 page 1683). 3. Perform a Collimation Check (see Job Card ELE A028 - Collimation Checks on page 679). 122/043 HALT COMPRESSION FORCE SENSOR FAILURE There is a compression force sensor defect. No frequency signal is detected from the compression force sensor. IPMS_SRS_SAR_013 = In case of defect on force sensor, the IPMS stops, and forbids the motion, and sends an error message IPMS_SRS_ERR_014. A1213 page 961 Check cabling between paddle holder and compression node. This error can be due to a too high reverse force applied on the paddle. If the reverse force is too sensitive, the Faulty FRU is the Compression trolley kit. 122/044 DEBUG ONLY COMPRESSION INVALID RX_OPTICAL_FOR K1_ERROR Ignore this error. If the problem persists, contact your OLC. 122/045 DEBUG ONLY COMPRESSION INVALID RX_OPTICAL_FOR K2_ERROR Ignore this error. If the problem persists, contact your OLC. 122/046 DEBUG ONLY Ignore this error. If the problem persists, contact your COMPRESSION OLC. INVALID LIFT_DOWN_PEDA L_ERROR Chapter 9 Page no. 888 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 122/047 DEBUG ONLY COMPRESSION Ignore this error. If the problem persists, contact your INVALID OLC. LIFT_UP_PEDAL_E RROR 122/048 DEBUG ONLY Ignore this error. If the problem persists, contact your COMPRESSION OLC. INVALID COMPRESSION_PE DAL_ERROR 122/049 DEBUG ONLY COMPRESSION INVALID DECOMPRESSION _PEDAL_ERROR 122/050 DEBUG ONLY Ignore this error. If the problem persists, contact your COMPRESSION OLC. INVALID STOP_MOTION_DS P_ACTIVE 122/051 DEBUG ONLY COMPRESSION INVALID CLUTCH_MALFUN CTION Ignore this error. If the problem persists, contact your OLC. 122/052 DEBUG ONLY COMPRESSION INVALID USERINTERFACE_ ERROR Ignore this error. If the problem persists, contact your OLC. 122/053 DEBUG ONLY Ignore this error. If the problem persists, contact your COMPRESSION OLC. INVALID COLLIMATOR_BUT TON_ERROR 122/054 HALT COMPRESSION INVALID RELAY_ERROR 122/055 DEBUG ONLY COMPRESSION INVALID UPPER_OPTICAL_ FORK_REACHED 122/056 DEBUG ONLY Ignore this error. If the problem persists, contact your COMPRESSION OLC. INVALID LOWER_OPTICAL_ FORK_REACHED 122/057 DEBUG ONLY COMPRESSION INVALID INITIALZATION_ER ROR Ignore this error. If the problem persists, contact your OLC. 122/058 HALT COMPRESSION INVALID UNCONTROLLED_ MOTION Ignore this error. If the problem persists, contact your OLC. Ignore this error. If the problem persists, contact your OLC. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. Ignore this error. If the problem persists, contact your OLC. Page no. 889 ERR-SUB-A-003.fm Job Card Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category 122/059 HALT 122/060 DEBUG ONLY Ignore this error. If the problem persists, contact your COMPRESSION OLC. INVALID GO_ROTATION_FA LIURE 122/061 DEBUG ONLY Ignore this error. If the problem persists, contact your COMPRESSION OLC. INVALID GO_ANGULATION_ FALIURE 122/062 DEBUG ONLY COMPRESSION INVALID UNDERSPEED_ER ROR Ignore this error. If the problem persists, contact your OLC. 122/063 DEBUG ONLY COMPRESSION INVALID POSITION_ERROR Ignore this error. If the problem persists, contact your OLC. 122/064 DEBUG ONLY COMPRESSION INVALID DECELERATION_E RROR Ignore this error. If the problem persists, contact your OLC. 122/065 DEBUG ONLY Ignore this error. If the problem persists, contact your COMPRESSION OLC. INVALID MOVEMENT_REVE RSE_DIRECTION 122/066 HALT 122/067 DEBUG ONLY COMPRESSION INVALID DSP_TIMEOUT_EL APSED 122/068 DEBUG ONLY Ignore this error. If the problem persists, contact your COMPRESSION OLC. INVALID TRANSMIT_QUEUE _FULL 122/069 DEBUG ONLY Occurs when the lift down pedal is depressed. COMPRESSION INVALID LIFT_DOWN_PEDA Ignore this error. If the problem persists, contact your OLC. L_PRESS 122/070 DEBUG ONLY Occurs when the lift up pedal is depressed. COMPRESSION INVALID LIFT_UP_PEDAL_P Ignore this error. If the problem persists, contact your OLC. RESS Chapter 9 Text in Log File or on LCD Possible Cause/Recommended Action Job Card COMPRESSION Reboot the system from the X-ray Console. If the INVALID problem persists, contact your OLC. SOFTWARE_ERRO R Reboot the system from the X-ray Console. If the COMPRESSION problem persists, contact your OLC. INVALID INTERNAL_SOFTW ARE_ERROR Ignore this error. If the problem persists, contact your OLC. Page no. 890 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category 122/071 DEBUG ONLY COMPRESSION Occurs when the compression pedal is depressed. INVALID COMPRESSION_PE Ignore this error. If the problem persists, contact your DAL_PRESS OLC. 122/072 DEBUG ONLY COMPRESSION INVALID DECOMPRESSION _PEDAL_PRESS 122/073 DEBUG ONLY 123/001 ADVISORY Text in Log File or on LCD LCD: A24 Maximum compression force is reached LCD: A05 Compression upper position is reached COMPR UP LIMIT ALREADY 123/003 ADVISORY Job Card Occurs when the decompression pedal is depressed. Ignore this error. If the problem persists, contact your OLC. Occurs when the collimator button is depressed. COMPRESSION INVALID COLLIMATOR_BUT Ignore this error. If the problem persists, contact your OLC. TON_PRESSED MAX COMPR FORCE ALREADY 123/002 ADVISORY Possible Cause/Recommended Action LCD: A23 Compression lower position is reached COMPR LOW LIMIT ALREADY Occurs when an operator presses the compression footswitch whereas the maximum compression force is already reached. Operator error. No service action required. Occurs when an operator presses the decompression footswitch whereas the upper software limit for the compression paddle positioning is already reached. Operator error. No service action required. Occurs when an operator presses the compression footswitch whereas the lower software limit for the compression paddle positioning is already reached. This can happen with no Breast Support and no Bucky. Operator error. No service action required. 123/004 ADVISORY COMPR NEGATIVE LIMIT REACHED Negative force limit reached. Occurs when the decompression motion is ongoing/ requested and a negative force limit is reached (-3 daN). Operator error. No service action required. Page no. 891 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages 3-4 Error Codes from 130/yyy: Tube Tilt Code Category Text in Log File or on LCD Possible Cause/Recommended Action 130/001 WARNING UIF Still pressed 130/002 WARNING UIF Still pressed 130/003 WARNING UIF Still pressed 130/004 WARNING UIF Still pressed 130/005 WARNING UIF Still pressed 130/006 WARNING UIF Still pressed 130/007 WARNING UIF Still pressed 130/008 WARNING UIF Still pressed UIF Still Pressed [i] (for i =1 - 9) = Occurs when one of the nine buttons on the Compression Arm or Tube Head is still pressed: - Lift up (V1, V2) - Lift down (V1, V2) - Rotation Right (V1, V2) - Rotation Left (V1, V2) - Light/Field Of View [i] indicates the nature of the button. Right or left is not indicated. 130/011 WARNING UIF Still pressed 130/012 WARNING UIF Still pressed 130/013 WARNING UIF Still pressed 130/014 WARNING UIF Still pressed 130/010 INHIBIT Tube Tilt initialization failure Job Card A1301 page 963 Refer to JC DIAG A1301 CONTROL KEYPAD FAILURE on page 963 to fix the problem. At power-up, in case the optical fork is shut or not, the Tube Tilt moves in one direction or the other in order to find the transition. After the transition has been found, the Tube Tilt goes up and down for a definite number of steps. The Tube Tilt board checks that the transition is reached after the good number of steps. If this series of Tube Tilt events does not occur, this error is produced. A1302 page 965 D/R A292 page 1397 Refer to JC DIAG A1302 TUBE HEAD CONTROL FAILURE on page 965 and to Job Card D/R A292 Tube Tilt Pivots on page 1397 to fix the problem. 131/001 INHIBIT Tube Tilt software error The software/firmware on the Tube Tilt board is corrupt. D/R A266 page 1365 Change the Tilt board then perform a Tilt Calibration. CAL A027 page 1681 131/002 INHIBIT Tube Tilt software error The software/firmware on the Tube Tilt board is corrupt. D/R A266 page 1365 Change the Tilt board then perform a Tilt Calibration. CAL A027 page 1681 131/003 INHIBIT Tube Tilt calib not achieved The Tube Tilt board has not been calibrated or has lost the current calibration settings. CAL A027 page 1681 Perform a Tilt Calibration. Chapter 9 Page no. 892 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 132/000 INHIBIT TILT INVALID PDO LENGTH Possible Cause/Recommended Action Job Card Change the Tilt board then perform a Tilt Calibration. D/R A266 page 1365 CAL A027 page 1681 132/001 INHIBIT Tube Tilt software error The software/firmware on the Tube Tilt board is corrupt. This failure is linked to a firmware problem (microcontroller or CPLD). Change the Tilt board then perform a Tilt Calibration. 132/002 WARNING Tube Tilt fan error D/R A266 page 1365 CAL A027 page 1681 The rotation speed of the FAN is monitored through a third wire. If it is not within an acceptable range, this signal is produced Change the Fan and cable W406. 132/003 HALT Tube Tilt switch defect 132/004 HALT Tube Tilt switch defect 132/005 HALT Tube Tilt switch defect 132/006 HALT Tube Tilt switch defect 132/007 HALT Tube Tilt switch defect 132/008 HALT Tube Tilt switch defect 132/009 HALT Tube Tilt switch defect 132/010 HALT Tube Tilt switch defect 132/025 HALT Tube Tilt switch defect 132/026 HALT Tube Tilt switch defect 132/027 HALT Tube Tilt switch defect SwitchDefect [i] (for i = 1 - 9) occurs when the two signals from the button do not arrive at the same time on the CPLD. The error signal indicates the nature of the button but not the side right or left. - Lift up (V1, V2) - Lift down (V1, V2) - Rotation Right (V1, V2) - Rotation Left (V1, V2) - Light/Field Of View - MLO +/- CC Refer to JC DIAG A1301 CONTROL KEYPAD FAILURE on page 963 to fix the problem. Page no. 893 ERR-SUB-A-003.fm A1301 page 963 Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 132/012 INHIBIT Tube Tilt step lost Possible Cause/Recommended Action After the transition has been found, the Tube Tilt goes up and down for a definite number of steps. The Tube Tilt board checks that the transition is reached after the good number of steps. If not, this error signal is produced. Job Card A1302 page 965 D/R A292 page 1397 Refer to JC DIAG A1302 TUBE HEAD CONTROL FAILURE on page 965 and to Job Card D/R A292 Tube Tilt Pivots on page 1397 to fix the problem. 132/013 INHIBIT TILT NODE FW INCOMPATIBILITY D/R A266 Occurs when the hardware configuration (CPLD) of page the node or the DSP or the MCU firmware not match. 1365 Change the Tilt board then perform a Tilt Calibration. CAL A027 page 1681 132/014 INHIBIT TILT NODE PARITY ERROR Occurs when the parity bit does not set correctly on the on-board bus between the CPLD and the MCU. D/R A266 page 1365 Change the Tilt board then perform a Tilt Calibration. CAL A027 page 1681 132/015 INHIBIT LOW VOLTAGE ERROR ON TILT NODE Occurs if the voltage of the power supply to the Tube Tilt board falls below 24 V. D/R A266 page 1365 Change the Tilt board then perform a Tilt Calibration. CAL A027 page 1681 132/016 INHIBIT TILT READ TIMEOUT ERROR Occurs if the MCU does not react within 15 ms of receiving an interrupt request (IRQ) coming from the CPLD. D/R A266 page 1365 Change the Tilt board then perform a Tilt Calibration. CAL A027 page 1681 132/017 INHIBIT TILT CPLD MEMORY ERROR Test data from the CPLD is periodically read to ensure the proper communication. This error occurs if this data from the CPLD does not match. D/R A266 page 1365 Change the Tilt board then perform a Tilt Calibration. CAL A027 page 1681 Chapter 9 Page no. 894 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 132/018 INHIBIT TILT COMMAND SEQUENCE IS INCORRECT Possible Cause/Recommended Action The checksum on the calibration data stored by the MCU does not match. Job Card D/R A266 page 1365 Change the Tilt board then perform a Tilt Calibration. CAL A027 page 1681 132/019 INHIBIT TILT MCU CALIBRATION DATA CORRUPT The checksum on the calibration data stored by the MCU does not match. Perform the tube tilt calibration, if the problem persists, change the tube tilt board. 132/020 INHIBIT TILT MCU EEPROM FAILURE The readback on the newly written data to the EEPROM failed. CAL A027 page 1681 D/R A266 page 1365 D/R A266 page 1365 Change the Tilt board then perform a Tilt Calibration. CAL A027 page 1681 132/021 INHIBIT TILT CAN COMMAND NOT PROCESSED The CAN command was not processed. The Gantry CPU has sent command to the compression node before the compression node could acknowledge the previous command. D/R A190 page 1131 CAL A029 page 1. Change the Gantry CPU Board (see Job Card D/ 1683 R A190 - Gantry CPU Board on page 1131). 2. Perform a Collimator Calibration (see Job Card ELE A028 CAL A029 - Collimator Format Calibration on page 679 page 1683). 3. Perform a Collimation Check (see Job Card ELE A028 - Collimation Checks on page 679). 132/022 INHIBIT TILT CAN BUFFER OVERRUN The input queue of the incoming CAN messages of the MCU is full and message dropped. Reboot the complete system. If the problem persists, check the other nodes (not tube tilt). If other nodes are good, check the tube tilt node (cabling, board). 132/023 INHIBIT TILT MAILBOX OVERRUN The mailbox queue used in the inter-task communication in the MCU is full and mails dropped. D/R A266 page 1365 Change the Tilt board then perform a Tilt Calibration. CAL A027 page 1681 Page no. 895 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 132/028 INHIBIT Tilt overcurrent Possible Cause/Recommended Action A motion over current is detected. Refer to JC DIAG A1305 TILT CONTROL FAILURE on page 966 and to Job Card D/R A292 - Tube Tilt Pivots on page 1397 to fix the problem. 132/029 INHIBIT CPU HEARTBEAT NOT RECEIVED BY TILT NODE A heartbeat failure occurred. The Gantry CPU did not send periodic "heartbeat" CAN message. Job Card A1305 page 966 D/R A292 page 1397 D/R A190 page 1131 1. Change the Gantry CPU Board (see Job Card D/ CAL A029 R A190 - Gantry CPU Board on page 1131). page 2. Perform a Collimator Calibration (see Job Card 1683 CAL A029 - Collimator Format Calibration on page 1683). 3. Perform a Collimation Check (see Job Card ELE ELE A028 page 679 A028 - Collimation Checks on page 679). 132/024 DEBUG ONLY HEARTBEAT DISABLED ON TILT NODE The Gantry CPU tried to disable the "heartbeat" check of the tilt node. D/R A190 page 1131 1. Change the Gantry CPU Board (see Job Card D/ CAL A029 R A190 - Gantry CPU Board on page 1131). page 2. Perform a Collimator Calibration (see Job Card 1683 CAL A029 - Collimator Format Calibration on page 1683). 3. Perform a Collimation Check (see Job Card ELE ELE A028 page 679 A028 - Collimation Checks on page 679). 132/030 DEBUG ONLY TILT INVALID RX_OPTICAL_FOR K1_ERROR Ignore this error. If the problem persists, contact your OLC. 132/031 DEBUG ONLY TILT INVALID RX_OPTICAL_FOR K2_ERROR Ignore this error. If the problem persists, contact your OLC. 132/032 DEBUG ONLY TILT INVALID Ignore this error. If the problem persists, contact your LIFT_DOWN_PEDA OLC. L_ERROR 132/033 DEBUG ONLY TILT INVALID Ignore this error. If the problem persists, contact your LIFT_UP_PEDAL_E OLC. RROR 132/034 DEBUG ONLY TILT INVALID Ignore this error. If the problem persists, contact your COMPRESSION_PE OLC. DAL_ERROR 132/035 DEBUG ONLY TILT INVALID DECOMPRESSION _PEDAL_ERROR 132/036 DEBUG ONLY TILT INVALID Ignore this error. If the problem persists, contact your STOP_MOTION_MC OLC. U_ACTIVE ERROR Chapter 9 Ignore this error. If the problem persists, contact your OLC. Page no. 896 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 132/037 DEBUG ONLY TILT INVALID Ignore this error. If the problem persists, contact your STOP_MOTION_DS OLC. P_ACTIVE ERROR 132/038 DEBUG ONLY TILT INVALID Ignore this error. If the problem persists, contact your STOP_MOTION_LIN OLC. E_ACTIVE ERROR 132/039 DEBUG ONLY TILT INVALID Ignore this error. If the problem persists, contact your BRAKE_MALFUNCT OLC. ION ERROR 132/040 DEBUG ONLY TILT INVALID CLUTCH_MALFUN CTION ERROR 132/041 DEBUG ONLY TILT INVALID Ignore this error. If the problem persists, contact your CODER_SEQUENC OLC. E_ERROR 132/042 DEBUG ONLY Ignore this error. If the problem persists, contact your TILT INVALID CODER_SIGNAL_E OLC. RROR 132/043 DEBUG ONLY TILT INVALID USERINTERFACE_ ERROR 132/044 DEBUG ONLY TILT INVALID Ignore this error. If the problem persists, contact your COLLIMATOR_BUT OLC. TON_ERROR 132/045 DEBUG ONLY TILT INVALID RELAY_ERROR Ignore this error. If the problem persists, contact your OLC. 132/046 DEBUG ONLY TILT INVALID CORELLATION_ER ROR Ignore this error. If the problem persists, contact your OLC. 132/047 DEBUG ONLY TILT INVALID UPPER_OPTICAL_ FORK_REACHED ERROR Ignore this error. If the problem persists, contact your OLC. 132/048 DEBUG ONLY Ignore this error. If the problem persists, contact your TILT INVALID LOWER_OPTICAL_ OLC. FORK_REACHED ERROR 132/049 DEBUG ONLY TILT INVALID FORCE_SENSOR_ DEFECT ERROR Ignore this error. If the problem persists, contact your OLC. 132/050 DEBUG ONLY TILT INVALID UNCONTROLLED_ MOTION ERROR Ignore this error. If the problem persists, contact your OLC. Possible Cause/Recommended Action Ignore this error. If the problem persists, contact your OLC. Ignore this error. If the problem persists, contact your OLC. Page no. 897 ERR-SUB-A-003.fm Job Card Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 132/051 DEBUG ONLY TILT INVALID ABSOLUTE_ENCO DER_RANGE_ERR OR Ignore this error. If the problem persists, contact your OLC. 132/052 DEBUG ONLY TILT INVALID FORCE_SENSOR_ RANGE_ERROR Ignore this error. If the problem persists, contact your OLC. 132/053 DEBUG ONLY TILT INVALID Ignore this error. If the problem persists, contact your SOFTWARE_ERRO OLC. R 132/054 DEBUG ONLY TILT INVALID Ignore this error. If the problem persists, contact your GO_ROTATION_FAI OLC. LURE 132/055 DEBUG ONLY Ignore this error. If the problem persists, contact your TILT INVALID GO_ANGULATION_ OLC. FAILURE 132/056 DEBUG ONLY TILT INVALID OVERSPEED_ERR OR Ignore this error. If the problem persists, contact your OLC. 132/057 DEBUG ONLY TILT INVALID UNDERSPEED_ER ROR Ignore this error. If the problem persists, contact your OLC. 132/058 DEBUG ONLY TILT INVALID POSITION_ERROR Ignore this error. If the problem persists, contact your OLC. 132/059 DEBUG ONLY TILT INVALID DECELERATION_E RROR Ignore this error. If the problem persists, contact your OLC. 132/060 DEBUG ONLY Ignore this error. If the problem persists, contact your TILT INVALID MOVEMENT_REVE OLC. RSE_DIRECTION ERROR 132/061 DEBUG ONLY TILT INVALID Ignore this error. If the problem persists, contact your INTERNAL_SOFTW OLC. ARE_ERROR 132/062 DEBUG ONLY TILT INVALID DSP_TIMEOUT_EL APSED ERROR 132/063 DEBUG ONLY TILT INVALID Ignore this error. If the problem persists, contact your TRANSMIT_QUEUE OLC. _FULL ERROR 132/064 DEBUG ONLY TILT INVALID Ignore this error. If the problem persists, contact your NO_PREVIOUS_UIF OLC. _EVENT ERROR Chapter 9 Job Card Ignore this error. If the problem persists, contact your OLC. Page no. 898 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 132/065 DEBUG ONLY TILT INVALID STOP_ON_VALID_ MOTION_DOWN ERROR Ignore this error. If the problem persists, contact your OLC. 132/066 DEBUG ONLY TILT INVALID Ignore this error. If the problem persists, contact your VALID_MOTION_AC OLC. TIVE ERROR 132/067 DEBUG ONLY TILT INVALID STOP_ON_UIF_RE LEASE ERROR 132/068 DEBUG ONLY TILT INVALID Occurs when the lift down pedal is depressed. LIFT_DOWN_PEDA L_PRESS ERROR Ignore this error. If the problem persists, contact your OLC. 132/069 DEBUG ONLY Occurs when the lift up pedal is depressed. TILT INVALID LIFT_UP_PEDAL_P RESS ERROR Ignore this error. If the problem persists, contact your OLC. 132/070 DEBUG ONLY Occurs when the compression pedal is depressed. TILT INVALID COMPRESSION_PE Ignore this error. If the problem persists, contact your DAL_PRESS OLC. ERROR 132/071 DEBUG ONLY TILT INVALID DECOMPRESSION _PEDAL_PRESS ERROR Ignore this error. If the problem persists, contact your OLC. Occurs when the decompression pedal is depressed. Ignore this error. If the problem persists, contact your OLC. Page no. 899 ERR-SUB-A-003.fm Job Card Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages 3-5 Error Codes from 140/yyy: Collimator Code Category Text in Log File or on LCD 140/001 INHIBIT COLLIMATOR SETUP TABLE CORRUPT Possible Cause/Recommended Action The setup_table corrupt = setup_table is initially blank and is filled in at collimator manufacturing. At power-up, the content of this table is automatically loaded into the control board DSP. If a checksum error exists after this loading, this error is produced 1. Reboot the system. If the problem persists (control board failure), identify the type of collimator currently in your system. 2. Replace the Collimator Set (refer to Job Card D/ R A280 - Collimator Set on page 1369). 3. Perform Collimator Format Calibration. 140/002 INHIBIT COLLIMATOR SOFTWARE ERROR D/R A280 page 1369 CAL A029 page 1683 FPGA configuration failed = At power-up, the control board DSP configures the FPGA with configuration data stored in a flash memory. If a configuration failure occurs, this error is produced. 1. Reboot the system, if the problem persists (control board failure), identify the type of collimator currently in your system. 2. Replace the Collimator Set (refer to Job Card D/ R A280 - Collimator Set on page 1369). 3. Perform Collimator Format Calibration. Chapter 9 Job Card D/R A280 page 1369 CAL A029 page 1683 Page no. 900 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 140/003 INHIBIT COLL FRONT BLADE HOMING FAIL 140/004 INHIBIT COLL LEFT BLADE HOMING FAIL 140/005 INHIBIT COLL REAR BLADE HOMING FAIL 140/006 INHIBIT COLL RIGHT BLADE HOMING FAIL Blade or filter wheel homing failure: axis[i] (for i=1 - 5) homing failed = At power-up. The five axes move one way or the other in order to find the transition of the optical sensors. After the transition has been found, the axes continue to come and go. Control board checks that the same transition is reached after the good number of steps. If not, error is produced on corresponding axis axis1: front blade, axis2: left blade, axis3: rear blade, axis4: right blade, axis5: filter Job Card A1402 page 967 Possible causes of error: - Axis not ready (together with error code indicating blade not ready). - Cannot find optical sensor and/or blade stuck (together with error code indicating blade overcurrent). - Error in multi-homing process; cannot find correct homing position. Actions to correct the problem: - Check collimator connections and reboot See JC DIAG A1402 COLL BLADE HOMING FAILURE on page 967 to fix the problem. 140/007 INHIBIT 141/001 INHIBIT Coll front blade not ready 141/002 INHIBIT Coll left blade not ready 141/003 INHIBIT Coll rear blade not ready 141/004 INHIBIT Coll right blade not ready 141/005 INHIBIT COLL FILTER HOM- Similar cause to BLADE HOMING FAIL. ING FAIL See JC DIAG A1403 COLL FILTER HOMING FAILURE on page 968 to fix the problem. Coll filter not ready Axis[i] (for i=1 - 5) is not ready = Gantry CPU sends a command to axis[i] whereas the axis is not in ready status. Possible reasons: 1. The frequency of system commands is too fast 2. Homing failure 3. Over_current error occurred A1404 page 968 See JC DIAG A1404 COLL BLADE AXIS NOT READY on page 968 to fix the problem. Similar cause to blade not ready. See JC DIAG A1405 COLL FILTER NOT READY on page 969 to fix the problem. Page no. 901 ERR-SUB-A-003.fm A1403 page 968 A1405 page 969 Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 141/006 INHIBIT Coll out of FOV (front) 141/007 INHIBIT 141/008 INHIBIT 141/009 INHIBIT Coll out of FOV (right) 141/010 INHIBIT Coll filter type not exist Possible Cause/Recommended Action Invalid parameter for axis[i] (for i=1 - 5) = collimator control board received a command for axis[i] that has Coll out of FOV (left) an invalid parameter. Either a wrong FOV value or a wrong filter type. Coll out of FOV(rear) Possible causes of error: - Collimator has received bad data on its node - Communication conflict/mismatch between system and collimator Actions to correct problem: 1. Check the cable connection (W409) between the collimator and system, then restart system from the X-ray Console. 2. If the problem persists, change the CPU board (re-calibrate the collimator afterwards). 3. If the problem persists, contact your OLC. 141/011 INHIBIT Coll beyond phy limit (front) 141/012 INHIBIT Coll beyond phy limit (left) 141/013 INHIBIT Coll beyond phy limit (rear) 141/014 INHIBIT Coll beyond phy limit (right) Job Card D/R A190 page 1131 CAL A029 page 1683 axis[i](for i=1 - 4) beyond physical limit = the FOV is beyond the blade capability. 1. Re-perform the collimator calibration. If the problem persists, identify the type of collimator currently in your system. 2. Replace the Collimator Set (refer to Job Card D/ R A280 - Collimator Set on page 1369). 3. Perform Collimator Format Calibration. D/R A280 page 1369 CAL A029 page 1683 Chapter 9 Page no. 902 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category 141/016 INHIBIT 141/017 INHIBIT 141/018 INHIBIT 141/019 INHIBIT Text in Log File or on LCD Possible Cause/Recommended Action Coll front blade time- Axis[i] (for i=1 - 5) time out = axis[i] does not reach out target position within timeout limit. Coll left blade time- Possible reasons: 1. Cables (drive cable or motor cable) are loose or out broken. Coll rear blade time- 2. Control board failure. out 3. Overcurrent during the movement. Coll right blade timeout Actions to correct problem: 1. Check into the error log if other error message occurs together with the Collimator timeout error. - If yes, replace the Collimator Set (refer to Job Card D/R A280 - Collimator Set on page 1369). - If not, check the motor drive cable (W501) and then restart the system. 2. If the error still exists, replace the Collimator Set (refer to Job Card D/R A280 - Collimator Set on page 1369). 3. Perform Collimator Format Calibration. 141/020 INHIBIT Coll filter timeout axis[i] (for i=1 - 5) time out = axis[i] does not reach target position within timeout limit. Possible reasons: 1. Cables (drive cable or motor cable) are loose or broken. 2. Control board failure. 3. Overcurrent during the movement. Actions to correct problem: 1. Move the filter wheel manually. Check whether there is mechanical interference with tube tilt plate screw. If there is mechanical interference with tube tilt plate screw, it may be linked to tube tilt plate assembly problem. 2. If not, check whether there is mechanical interference between the filter wheel flag and the small filter gear. 3. If there is mechanical interference between the filter wheel flag and the small filter gear, change the Collimator set. Refer to Job Card D/R A280 Collimator Set on page 1369. 4. If not, refer to the actions for the Blade Timeout error. Page no. 903 ERR-SUB-A-003.fm Job Card D/R A280 page 1369 CAL A029 page 1683 D/R A280 page 1369 CAL A029 page 1683 Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 141/021 INHIBIT Coll PDO1 length error 141/022 INHIBIT Coll PDO2 length error 141/023 INHIBIT Coll PDO3 length error PDO[i] (for i=1 - 4) length error = it is a standard error signal. The Gantry CPU sends a command message which contains a certain number of databytes. In case the length of the PDO is not adequate, this signal is produced. PDO1: change FOV, PDO2: change filter type, PDO3: lamp on/off, PDO4: change focal spot 141/024 INHIBIT Coll PDO4 length error Possible causes of error: • Collimator has received bad data on its node • Communication conflict/mismatch between system and collimator Actions to correct problem: 1. Check the cable connection (W409) between the collimator and system, then restart system. 2. If the problem persists, change the CPU board (re-calibrate the collimator afterwards). 3. If the problem persists, contact your OLC. 142/001 DEBUG ONLY Coll 12V lamp power failure The power is down for 12 VDC (lamp). Job Card D/R A190 page 1131 CAL A029 page 1683 A1401 page 967 See JC DIAG A1401 LIGHT CENTERING FAILURE on page 967 to fix the problem. 142/003 INHIBIT 142/004 INHIBIT 142/005 INHIBIT 142/006 INHIBIT 142/007 INHIBIT Coll front blade over- Axis[i] (for i=1 - 5) is protected = the axis is procurrent tected. This is either because the motor current is Coll left blade over- over threshold for more than accepted range, or there is abnormal noise on control board. current Possible reasons for overcurrent: Coll rear blade over- 1. Mechanical resistance is too big current 2. Control board failure Coll right blade over- 3. The frequency of system commands is too fast current See JC DIAG A1406 COLL BLADE OVERCURRENT on page 970 to fix the problem. Coll filter overcurrent Like blade overcurrent. See JC DIAG A1407 COLL FILTER OVERCURRENT on page 970 to fix the problem. Chapter 9 A1406 page 970 A1407 page 970 Page no. 904 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category 142/011 INHIBIT Text in Log File or on LCD Possible Cause/Recommended Action Cannot reach Filter positioning error requested filter posi- During filter position change from Mo to Rh or vice tion versa, the control board checks the transition of optical sensor. If the optical sensor signal is not received at expected position, this error is produced. Possible reasons: 1. Filter gear loose 2. Optical sensor failure 3. Control board failure Actions to correct problem: 1. Change Collimator Set. Refer to Job Card D/R A280 - Collimator Set on page 1369. 2. Perform Collimator Format Calibration. Page no. 905 ERR-SUB-A-003.fm Job Card D/R A280 page 1369 CAL A029 page 1683 Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages 3-6 Error Codes from 150/yyy: PDU Code Category 152/000 DEBUG ONLY 152/001 WARNING Text in Log File or on LCD Possible Cause/Recommended Action PDU 230V AC mains The 230 V AC mains is out of the specified limits. is out of the spec limits See JC DIAG A1500 AC MAINS FAILURE on page 971 to fix the problem. 12VDC Generator voltage off The 12 V DC signal from Generator Supply Command board to PDU board is not present. Job Card A1500 page 971 A1501 page 971 See JC DIAG A1501 12V DC Generator Voltage Off on page 971 to fix the problem. 152/002 DEBUG ONLY 48V DC channel error The AC/DC module is turned on but no 48 V DC is detected. A1502 page 973 See JC DIAG A1502 ACDC MODULE POWER FAILURE on page 973 to fix the problem. 152/003 WARNING Power Fail The power on the AC/DC module has failed. A1508 page 976 See JC DIAG A1508 AC/DC Module Reports Power Failure on page 976 to fix the problem. 152/004 DEBUG ONLY Fan Fail The fan on the AC/DC module has failed. A1509 page 976 See JC DIAG A1509 AC/DC Module Reports Fan Failure on page 976 to fix the problem. 152/005 WARNING Over Temperature The temperature of the AC/DC module has exceeded the specified limits. A1510 page 976 See JC DIAG A1510 AC/DC Module Reports Over Temperature on page 976 to fix the problem. 152/006 DEBUG ONLY Internal 12VDC voltage is out of spec limits The internal (regulated) 12 V DC voltage is out of the specified limits. Ignore this error. If the error persists, contact your OLC. 152/007 DEBUG ONLY Total current consumption is too high The total current consumption of PDU is too high (i.e. greater than 40 A). A1503 page 974 See JC DIAG A1503 OVERCURRENT FAILURE on page 974 to fix the problem. 152/008 DEBUG ONLY GND offset. Level of PDU ground is too high The level of PDU ground is too high (possible noise is present). Check the Shunt R101 and cables W109, W111, and W113. If the problem persists, change PDU board (see Job Card D/R A191 - PDU Board on page 1137). Chapter 9 Page no. 906 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 152/009 DEBUG ONLY Internal 13.3V voltage is out of spec limits The internal 13.3V voltage is out of the specified limits. Job Card Ignore this error. If the error persists, contact your OLC. 152/010 DEBUG ONLY Internal 5V DC voltage is out of spec limits The internal 5 V DC voltage is out of the specified limits. Ignore this error. If the error persists, contact your OLC. 152/011 DEBUG ONLY Negative unregulated voltage is out of spec limits The negative unregulated voltage (coming from transformation) is out of the specified limits. Ignore this error. If the error persists, contact your OLC. 152/012 DEBUG ONLY Positive unregulated voltage is out of spec limits The positive unregulated voltage (coming from transformation) is out of the specified limits. Ignore this error. If the error persists, contact your OLC. 152/013 DEBUG ONLY Internal -5V DC volt- The internal -5V DC voltage is out of the specified limits. age is out of spec limits Ignore this error. If the error persists, contact your OLC. 152/014 DEBUG ONLY Internal 5V DC voltage is out of spec limits The internal 5 V DC voltage is out of the specified limits. Ignore this error. If the error persists, contact your OLC. 152/015 152/019 DEBUG ONLY DEBUG ONLY Internal reference voltage for AD conversions is out of spec limits The internal reference voltage for A/D conversions is out of the specified limits. Internal 0.6 volts is bad. Measurement circuit error The internal 0.6 V is bad due to a measurement circuit error. Ignore this error. If the error persists, contact your OLC. Ignore this error. If the error persists, contact your OLC. 152/020 DEBUG ONLY Internal EEPROM error The PDU MCU has failed. This error is also generated when EEPROM is empty. This behavior is normal during the first 5 s after the PDU is first turned on. Ignore this error. If the error persists, contact your OLC. Page no. 907 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 152/021 DEBUG ONLY PDU MCU reseted while System is ON Possible Cause/Recommended Action Job Card The PDU MCU was reset while the system was on. Ignore this error. If the error persists, contact your OLC. 152/022 DEBUG ONLY A/D converter module error on PDU board The A/D converter on the PDU board (U13) is bad and the measurements are invalid. Ignore this error. If the error persists, contact your OLC. 152/023 152/024 DEBUG ONLY DEBUG ONLY Diagnostic channel selection circuit failure Internal software error PDU internal error Ignore this error. If the error persists, contact your OLC. There has been an internal error with the PDU software. Ignore this error. If the error persists, contact your OLC. 152/025 DEBUG ONLY Temperature is too high or too low The MPCB box temperature is out of the specified +9 to +60 degrees operating range. Ignore this error. If the error persists, contact your OLC. 152/026 HALT Low power 2 fuse failure The low power 2 fuse (F1) to the nodes is faulty. A1504 page 975 See JC DIAG A1504 LOW POWER 2 FUSE IS BAD on page 975 to fix the problem. 152/027 HALT 152/028 HALT High power fuse fail- The high power fuse (F2) to the motors is faulty. ure See JC DIAG A1505 HIGH POWER FUSE IS BAD on page 975 to fix the problem. Low power 1 fuse failure The low power 1 fuse (F3) to the nodes is faulty. A1505 page 975 A1506 page 975 See JC DIAG A1506 LOW POWER 1 FUSE IS BAD on page 975 to fix the problem. 152/029 DEBUG ONLY CPU fuse failure The CPU fuse (F4) is faulty. A1507 page 975 See JC DIAG A1507 MAIN CPU FUSE IS BAD on page 975 to fix the problem. 152/030 HALT Generator on off relay failure Generator on/off switch relay (or its driver) is faulty. The relay that turns off the Generator at shutdown has over/under current on its drive coil. Check the following relays: Relay-X1 16 A Relay-K1 K2 8 A Relay-18A 230 V Chapter 9 Page no. 908 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 152/031 DEBUG ONLY Spare relay failure Possible Cause/Recommended Action Job Card The spare relay or its driver is faulty or not present on the board. Check the following relays: Relay-X1 16 A Relay-K1 K2 8 A Relay-18A 230 V 152/032 DEBUG ONLY 152/033 HALT Internal AD converter The internal A/D converter has suffered an error. failure Ignore this error. No service action is required. Generator cannot be turned off by PDU The Generator relay has failed or the cabling and connections between the Generator and PDU are not correctly established. Check the error logs to see whether error 0x5010 is also reported. If yes, relay is damaged and needs replacing. If not, the relay is fine, and you must check cabling and connections. Page no. 909 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages 3-7 Error Codes from 160/yyy: CPU Code Category Text in Log File or on LCD Possible Cause/Recommended Action 160/000 HALT INTERNAL SOFTWARE ERROR One of the following out of memory errors occurred: - functional device creation fails - configuration interface creation fails - HAL device creation fails Job Card Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 160/001 HALT INTERNAL SOFTWARE ERROR A Common Object Request Broker Architecture (CORBA) extraction failed. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 160/002 HALT INTERNAL SOFTWARE ERROR An unknown attribute change notification, HAL signal, or Atlas event was received. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 160/003 HALT INTERNAL SOFTWARE ERROR The Gantry CPU failed to read the configuration file. 1. Reboot the system from the X-ray Console. 2. If the problem persists change the CPU Board and re-calibrate the Collimator afterwards. 3. If the problem persists, contact your OLC. D/R A190 page 1131 CAL A029 page 1683 ELE A028 page 679 160/004 HALT INTERNAL SOFTWARE ERROR The Gantry CPU failed to get the configuration data. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 160/005 HALT INTERNAL SOFTWARE ERROR An Atlas event, attribute change, or HAL signal subscription has failed. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 160/006 HALT INTERNAL SOFTWARE ERROR The Gantry CPU was unable to access the state machine file. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 160/007 HALT INTERNAL SOFTWARE ERROR The Gantry CPU failed to get an attribute. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. Chapter 9 Page no. 910 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 160/008 HALT INTERNAL SOFTWARE ERROR Possible Cause/Recommended Action Job Card The Gantry CPU failed to set an attribute. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 160/009 HALT INTERNAL SOFTWARE ERROR The Gantry CPU failed to publish an event. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 160/011 HALT INTERNAL SOFTWARE ERROR An error code was received from a known node, but it was not handled by the Gantry CPU in the actual release. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 160/012 HALT 160/013 ADVISORY AUTO-REBOOT MAX RETRY ATTEMPTS REACHED The Gantry CPU failed to boot up on 3 consecutive attempts. AUTO-REBOOT RECOVERY STARTED The Gantry CPU failed to boot up and is retrying the operation. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. If system boots successfully, no action is required. If three reboot attempts are made and fail a 160/012 HALT error is raised. 161/001 HALT INTERNAL SOFTWARE ERROR The Gantry CPU received an unknown UIF request. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 161/008 ADVISORY LCD: A07 Lift is not operational The Gantry CPU received a lift UIF request while the lift node is not operational. Operator error. No service recommended actions. 161/009 ADVISORY LCD: A18 Rotation is not operational The Gantry CPU received a rotation UIF request while the rotation node is not operational. Operator error. No service recommended actions. 161/010 ADVISORY LCD: A03 Compression is not operational The Gantry CPU received a compression UIF request while the compression node is not operational. Operator error. No service recommended actions. 161/011 ADVISORY LCD: A10 Motion stopped. Multiple movements are requested The compression motion was stopped because the Gantry CPU received an inconsistent UIF request. Operator error. No service recommended actions. Page no. 911 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category 161/012 ADVISORY 161/013 ADVISORY 161/014 ADVISORY Text in Log File or on LCD Possible Cause/Recommended Action LCD: A10 Motion stopped. Multiple movements are requested The lift motion was stopped because the Gantry CPU received an inconsistent UIF request. LCD: A10 Motion stopped. Multiple movements are requested The rotation motion was stopped because the Gantry CPU received an inconsistent UIF request. LCD: A10 Motion stopped. Multiple movements are requested The rotation UIF request was rejected by the Gantry CPU because a compression motion is currently active. Job Card Operator error. No service recommended actions. Operator error. No service recommended actions. Operator error. No service recommended actions. 161/015 ADVISORY 161/016 ADVISORY LCD: A10 Motion stopped. Multiple movements are requested The rotation UIF request was rejected by the Gantry CPU because a lift motion is currently active. LCD: A02 Compression force is applied The rotation UIF request was rejected by the Gantry CPU because a compression force is currently applied. Operator error. No service recommended actions. Operator error. No service recommended actions. 161/017 ADVISORY 161/018 ADVISORY 161/019 ADVISORY LCD: A10 Motion stopped. Multiple movements are requested The lift UIF request was rejected by the Gantry CPU because a compression motion is currently active. LCD: A10 Motion stopped. Multiple movements are requested The lift UIF request was rejected by the Gantry CPU because a lift motion is currently active. LCD: A02 Compression force is applied The lift UIF request was rejected by the Gantry CPU because a compression force is currently applied. Operator error. No service recommended actions. Operator error. No service recommended actions. Operator error. No service recommended actions. 161/020 ADVISORY LCD: A10 Motion stopped. Multiple movements are requested The compression UIF request was rejected by the Gantry CPU because a rotation motion is currently active. Operator error. No service recommended actions. 161/021 ADVISORY 161/022 ADVISORY LCD: A10 Motion stopped. Multiple movements are requested The compression UIF request was rejected by the Gantry CPU because a rotation lift is currently active. LCD: A15 Rotation end position is reached The rotation UIF request was rejected by the Gantry CPU because it is already at its end position. Operator error. No service recommended actions. Operator error. No service recommended actions. Chapter 9 Page no. 912 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category 161/023 ADVISORY Text in Log File or on LCD Possible Cause/Recommended Action LCD: A06 Lift end position is reached The lift UIF request was rejected by the Gantry CPU because it is already at its end position. Job Card Operator error. No service recommended actions. 161/024 ADVISORY LCD: A05 Compression upper position is reached The compression UIF request was rejected by the Gantry CPU because it is already in its topmost position. Operator error. No service recommended actions. 161/025 ADVISORY 161/026 ADVISORY 161/027 ADVISORY LCD: A09 Max power driven compression force is reached The maximum power-driven compression force has been reached. Operator error. No service recommended actions. LCD: A08 Max man- The maximum manual compression force has been ual compression reached. force is reached Operator error. No service recommended actions. LCD: A14 Risk of collision with floor An active lift motion was stopped or a lift UIF request was rejected because a potential collision situation was detected by the Gantry CPU. Operator error. No service recommended actions. 161/028 ADVISORY LCD: A14 Risk of collision with floor A rotation lift motion was stopped or a rotation UIF request was rejected because a potential collision situation was detected by the Gantry CPU. Operator error. No service recommended actions. 161/030 HALT COMPRESSION The compression node did not start. At power-up, CONTROL FAILURE the compression node sends an acknowledgment (which can be different from the first heartbeat signal) to Gantry CPU. If the compression node does not send an acknowledgment, the Gantry CPU creates this error. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 161/031 HALT LIFT CONTROL FAILURE The lift node did not start. At power-up, the lift node sends an acknowledgment (which can be different from the first heartbeat signal) to Gantry CPU. If the lift node does not send an acknowledgment, the Gantry CPU creates this error. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. Page no. 913 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 161/032 HALT ROTATION CONTROL FAILURE The rotation node did not start. At power-up, the rotation node sends an acknowledgment (which can be different from the first heartbeat signal) to Gantry CPU. If the rotation node does not send an acknowledgment, the Gantry CPU creates this error. Job Card Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 161/036 HALT LIFT NODE NOT RESPONDING Possible causes: • The Lift node did not send the Heartbeat signal. Between two motions, the lift node sends a Heartbeat signal every second to Gantry CPU. If not, the Gantry CPU creates this error. During lift motion, the lift node sends an actual value message regularly in addition to the heartbeat. If not, the Gantry CPU creates this error. • The TP2 connector on the Lift board is closed. Proceed as follows: 1. Reboot the system from the X-ray Console. 2. If the problem persists check the error logs. If this error occurs in conjunction with error 167/007, there is a possibility that a jumper exists on the TP2 connector on the Lift board. In this case you must remove the jumper from the TP2 connector on the Lift board. 3. If the problem persists, contact your OLC. 161/037 HALT ROTATION NODE Possible causes: NOT RESPONDING • The Rotation node did not send the Heartbeat signal. Between two motions, the rotation node sends a Heartbeat signal every second to Gantry CPU. If not, the Gantry CPU creates this error. During lift motion, the rotation node sends an actual value message regularly in addition to the heartbeat. If not, the Gantry CPU creates this error. • The TP2 connector on the Rotation board is closed. Proceed as follows: 1. Reboot the system from the X-ray Console. 2. If the problem persists check the error logs. If this error occurs in conjunction with error 167/008, there is a possibility that a jumper exists on the TP2 connector on the Rotation board. In this case you must remove the jumper from the TP2 connector on the Rotation board. 3. If the problem persists, contact your OLC. Chapter 9 Page no. 914 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 161/038 HALT COMPR NODE NOT RESPONDING Possible causes: • The Compression node did not send the Heartbeat signal. Between two motions, the compression node sends a Heartbeat signal every second to Gantry CPU. If not, the Gantry CPU creates this error. During lift motion, the compression node sends an actual value message regularly in addition to the heartbeat. If not, the Gantry CPU creates this error. • The TP1 connector on the Compression board is closed. Proceed as follows: 1. Reboot the system from the X-ray Console and perform a compression motion before a complete Gantry boot. 2. If the problem persists check the error logs. If this error occurs in conjunction with error 167/004, there is a possibility that a jumper exists on the TP1 connector on the Compression board. In this case you must remove the jumper from the TP1 connector on the Compression board. 3. If the problem persists, change the Compression Board (Firmware or Hardware problem) and recalibrate compression force sensor and compression thickness. 4. If the problem persists, check CAN bus. 161/039 HALT INTERNAL SOFTWARE ERROR Job Card D/R A250 page 1323 CAL A048 page 1709 CAL A050 page 1721 The Gantry CPU received an unknown error code from the lift node. 1. Reboot the system from the X-ray Console. 2. If the problem persists check then check the debug text into the error log, - If the error code is 20497, replace both footswitches. - If the error code is 20535, replace the lift poten- D/R A204 page tiometer. 1175 - If the error code is 20545, reboot the system and if the problem persists with error code 20545 D/R A201 then replace the lift board. page - if the error code is different contact your OLC. 1161 Page no. 915 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 161/040 HALT INTERNAL SOFTWARE ERROR Possible Cause/Recommended Action The Gantry CPU received an unknown error code from the rotation node. 1. Reboot the system from the X-ray Console. 2. If the problem persists check then check the debug text into the error log, - If the error code is 20535, replace the rotation potentiometer. - If the error code is 20545, reboot the system and if the problem persists with error code 20545 then replace the rotation board. - if the error code is different contact your OLC. 161/041 HALT INTERNAL SOFTWARE ERROR Job Card D/R A227 page 1239 D/R A221 page 1223 The Gantry CPU received an unknown error code from the compression node. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 161/043 HALT ROTATION COMMUNICATION ERROR Possible causes: • The rotation node failed to communicate with the Gantry CPU. • The TP2 connector on the Rotation board is closed. Proceed as follows: 1. Reboot the system from the X-ray Console. 2. If the problem persists check the error logs. If this error occurs in conjunction with error 167/008, there is a possibility that a jumper exists on the TP2 connector on the Rotation board. In this case you must remove the jumper from the TP2 connector on the Rotation board. 3. If the problem persists, contact your OLC. 161/044 ADVISORY LCD: A04 Compression status is unknown The compression UIF request was rejected by the Gantry because the stereotix compression status is unknown. Operator error. No service recommended actions. 161/045 ADVISORY LCD: A04 Compression status is unknown The rotation UIF request was rejected by the Gantry because the stereotix compression status is unknown. Operator error. No service recommended actions. 161/046 ADVISORY LCD: A04 Compression status is unknown The lift UIF request was rejected by the Gantry because the stereotix compression status is unknown. Operator error. No service recommended actions. Chapter 9 Page no. 916 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 161/050 HALT COMPRESSION COMMUNICATION ERROR Possible Cause/Recommended Action Job Card The compression node failed to communicate with the Gantry CPU. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 161/051 HALT LIFT COMMUNICATION ERROR The lift node failed to communicate with the Gantry CPU. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 162/000 INHIBIT INTERNAL SOFTWARE ERROR The Gantry CPU received an unknown error code from the lift node. 1. Reboot the system from the X-ray Console. 2. If the problem persists, contact your OLC (problem linked to Bucky). 162/001 INHIBIT TUBE TILT CAN AFFECT IQ The Gantry CPU received an unknown error code from the tilt node. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 162/003 INHIBIT TILT NODE NOT STARTED Possible causes: • The tilt node did not start. At power-up, the tilt node sends an acknowledgment (which can be different from the first heartbeat signal) to Gantry CPU. If the tilt node does not send an acknowledgment, the Gantry CPU creates this error. • The TP1 connector on the Tilt board is closed. Proceed as follows: 1. Reboot the system from the X-ray Console and perform a compression motion before a complete Gantry boot. 2. If the problem persists check the error logs. If this error occurs in conjunction with error 162/006, there is a possibility that a jumper exists on the TP1 connector on the Tilt board. In this case you must remove the jumper from the TP1 connector on the Tilt board. 3. If the problem persists, change the Tilt Board (Firmware or Hardware problem) and re-calibrate compression force sensor and compression thickness. 4. If the problem persists, check CAN bus. Page no. 917 ERR-SUB-A-003.fm D/R A266 page 1365 CAL A027 page 1681 CAL A048 page 1709 CAL A050 page 1721 Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action Job Card 162/005 INHIBIT GRID NODE NOT STARTED The grid node did not start. At power-up, the grid node sends an acknowledgment (which can be different from the first heartbeat signal) to Gantry CPU. If the grid node does not send an acknowledgment, the Gantry CPU creates this error. D/R A255 page 1361 1. Reboot the system from the X-ray Console. 2. If the problem persists then change the Bucky and check the mechanical thickness. 162/006 INHIBIT TILT NODE NOT RESPONDING ELE A015 page 579 Possible causes: • The Tilt node did not send the heartbeat signal. Between two motions, the tilt node sends a Heartbeat signal every second to Gantry CPU. If not, the Gantry CPU creates this error. During lift motion, the tilt node sends an actual value message regularly in addition to the heartbeat. If not, the Gantry CPU creates this error. • The TP1 connector on the Tilt board is closed. Proceed as follows: 1. Reboot the system from the X-ray Console. 2. If the problem persists check the error logs. If this error occurs in conjunction with error 162/003, there is a possibility that a jumper exists on the TP1 connector on the Tilt board. In this case you must remove the jumper from the TP1 connector on the Tilt board. 3. If the problem persists, contact your OLC. 162/007 INHIBIT GRID NODE NOT RESPONDING Possible causes: • The grid node did not send the heatbeat signal. Between two motions, the grid node sends a Heartbeat signal every second to Gantry CPU. If not, the Gantry CPU creates this error. During lift motion, the grid node sends an actual value message regularly in addition to the heartbeat. If not, the Gantry CPU creates this error. Proceed as follows: 1. Reboot the system from the X-ray Console. If the problem persists contact your OLC. 2. If the problem persists, contact your OLC. 162/008 ADVISORY LCD: A14 Risk of collision with floor An active angulation motion was stopped or an angulation UIF request was rejected because a potential collision situation was detected by the Gantry CPU. Operator error. No service recommended actions. Chapter 9 Page no. 918 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category 162/009 HALT 162/010 INHIBIT Text in Log File or on LCD Possible Cause/Recommended Action Job Card STEREOTIX HARD- The Gantry CPU failed to detect the stereotix hardWARE DETECTION ware. IN FAILURE Reboot the system from the X-Ray Console. If the problem persists contact your OLC. STEREOTIX CAN NOT ENTER READY STATE The stereotix node can not switch to the READY state. Reboot the system from the X-Ray Console. If the problem persists contact your OLC. 162/011 INHIBIT 162/012 WARNING STEREOTIX CAN The stereotix node can not switch to the PUNCTURE NOT ENTER PUNC- state. TURE STATE Reboot the system from the X-Ray Console. If the problem persists contact your OLC. STEREOTIX TARGET LIST IS FULL The stereotix node's target list is FULL. Reboot the system from the X-Ray Console. If the problem persists contact your OLC. 162/013 HALT STEREOTIX NODE Heartbeat signal was not sent by the stereotix node. NOT RESPONDING The stereotix node sends a Heartbeat signal every second to Gantry CPU. If not, the Gantry CPU creates this error. This error occurs when an operator did not disconnect the stereotix within 10s after releasing the latches (time out). Operator error. After releasing the latches, operator has 10s to disconnect the stereotix. Reboot the system from the console then redo the operation into the allocated timestamp. 162/014 HALT INTERNAL SOFTWARE ERROR The Gantry CPU received an unknown error code from the stereotix node. Reboot the system from the X-Ray Console. If the problem persists contact your OLC. 162/015 ADVISORY LCD: A19 Stereotac- The stereotix positioner is not ready. tic Positioner is not ready Operator error. No service recommended actions. 162/016 ADVISORY LCD: A12 Move tube head to center position Move to angulation 0° LCD: A16 Rotation limit for Stereotaxy is reached Stereotactic rotation limit reached. 162/017 ADVISORY Operator error. No service recommended actions. Operator error. No service recommended actions. Page no. 919 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category 162/019 ADVISORY 162/020 ADVISORY Text in Log File or on LCD Possible Cause/Recommended Action LCD: A04 Compression status is unknown Compression status is unknown. LCD: A13 Move up the paddle holder Move up the paddle holder. Job Card Operator error. No service recommended actions. Operator error. No service recommended actions. 162/021 ADVISORY 162/022 ADVISORY LCD: A01 Angulation mode not allowed Angulation mode refused. LCD: A17 Rotation mode not allowed Rotation mode refused. Operator error. No service recommended actions. Operator error. No service recommended actions. 162/023 ADVISORY Risk of collision with gun. LCD: A11 Motion stopped; risk of collision with puncture Operator error. No service recommended actions. tool 162/024 ADVISORY LCD: A12 Move tube head to center position Move tube head to center position. Operator error. No service recommended actions. 162/025 ADVISORY LCD: A21 No Gantry Inconsistent operator request. motion while StereotOperator error. No service recommended actions. actic Positioner motion 162/028 HALT LCD: H16 Stereotac- Node Failure (Fault State). tic Pos control failed Reboot the system from the X-Ray Console. If the problem persists contact your OLC. 162/029 HALT STEREOTAXY COMMUNICATION ERROR The stereotix node failed to communicate with the Gantry CPU. Reboot the system from the X-Ray Console. If the problem persists contact your OLC. 162/032 INHIBIT FOCUS IS UNKNOWN The Gantry CPU does not know the current focus status of the X-ray. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 162/033 INHIBIT TRACK is UNKNOWN The Gantry CPU does not know the current track status of the X-ray. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. Chapter 9 Page no. 920 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 163/000 INHIBIT INVALID BUCKY TYPE The Gantry CPU received an invalid image receptor type. Job Card Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 163/001 INHIBIT INVALID PADDLE DETECTED The Gantry CPU received an invalid paddle type. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 163/005 HALT INTERNAL SOFTWARE ERROR The Gantry CPU received an invalid button function identity. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 163/006 HALT INTERNAL SOFTWARE ERROR The Gantry CPU received an invalid button state. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 163/007 HALT INTERNAL SOFTWARE ERROR There is a button state inconsistency. The lift or rotation button counter on the Gantry CPU has overflown or underflown. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 163/105 WARNING INVALID LANGUAGE. DEFAULT USED An invalid language is currently configured on, and English is currently being used. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 164/001 INHIBIT BLADE FORMAT OUT OF FOV The blade configuration in the collimator is outside the current field of view (FOV) setting. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 164/002 INHIBIT INTERNAL SOFTWARE ERROR The Gantry CPU received a machine event with an unexpected state. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 164/003 INHIBIT COMMUNICATION A timeout command on the Gantry CPU is waiting for ERROR WITH COL- a response from the collimator. LIMATOR NODE Reboot the system from the X-ray Console. If the problem persists, contact your OLC. Page no. 921 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category 164/004 INHIBIT 164/005 INHIBIT Text in Log File or on LCD Possible Cause/Recommended Action Job Card COMMUNICATION The Gantry CPU was unable to load the collimator ERROR WITH COL- parameters. LIMATOR NODE Reboot the system from the X-ray Console. If the problem persists, contact your OLC. INTERNAL SOFTWARE ERROR The Gantry CPU received an unknown error code from the collimator node. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 164/006 INHIBIT COLLIMATOR CON- The collimator node did not start. At power-up, the TROL ERROR collimator node sends an acknowledgment (which can be different from the first heartbeat signal) to Gantry CPU. If the collimator node does not send an acknowledgment, the Gantry CPU creates this error. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 164/008 INHIBIT COLLIMATOR NODE NOT RESPONDING The collimator node did not send the Heartbeat signal. Between two motions, the collimator node sends a Heartbeat signal every second to Gantry CPU. If not, the Gantry CPU creates this error. During lift motion, the lift collimator sends an actual value message regularly in addition to the heartbeat. If not, the Gantry CPU creates this error. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 165/000 INHIBIT Internal software error There is an invalid serial port configuration, and therefore no communication is possible between the Gantry CPU and the Generator. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 165/001 INHIBIT Internal software error There is a hardware error with the COM port, and therefore no communication is possible between the Gantry CPU and the Generator. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 165/002 INHIBIT Internal software error Received message number does not match. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. Chapter 9 Page no. 922 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 165/003 INHIBIT Internal software error Possible Cause/Recommended Action Job Card Received message BCC does not match. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 165/004 INHIBIT Internal software error RX Buffer FULL. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 165/005 INHIBIT Internal software error TX Buffer FULL. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 165/006 INHIBIT GENERATOR DISCONNECTED A message from the Gantry CPU can not be sent to Generator because Generator is not connected or powered down. Check cable connections between the Generator and the Gantry CPU Board. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 165/007 INHIBIT Internal software error Events count not found. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 165/008 INHIBIT Internal software error Event number from the list not defined. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 165/009 DEBUG ONLY Internal software error Revision description not found in file. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 165/010 INHIBIT Internal software error Messages count not found. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 165/011 INHIBIT Internal software error Messages number from the list not defined. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 165/014 INHIBIT Internal software error Message count not defined. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. Page no. 923 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 165/015 INHIBIT Internal software error Possible Cause/Recommended Action Job Card Message list not defined. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 165/016 INHIBIT Internal software error Simulation Message description error. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 165/017 INHIBIT Internal software error Simulation Message Flag description error. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 165/018 INHIBIT Internal software error Message description error. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 166/000 INHIBIT OPEN SOCKET FAILED Open socket failed. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 166/001 INHIBIT CLOSE SOCKET FAILED Close socket failed. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 166/002 INHIBIT ACCEPT CONNECTION FAILED The incoming connection was not accepted. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 166/003 INHIBIT TCP/IP PACKET TRANSMISSION FAILED A TCP/IP packet transmitted from the Gantry to another node in the Senographe System failed Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 166/004 INHIBIT TCP/IP PACKET RECEPTION FAILED The Gantry failed to receive a TCP/IP packet originating from another node in the Senographe System. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 166/005 INHIBIT TCP/IP PACKET TOO LONG The Gantry received a TCP/IP packet originating from another node in the Senographe System, but rejected it because it was too long. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. Chapter 9 Page no. 924 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category 166/006 INHIBIT Text in Log File or on LCD Possible Cause/Recommended Action Job Card TCP/IP PACKET The Gantry received a TCP/IP packet originating WITH WRONG SIZE from another node in the Senographe System, but rejected it because it was the wrong size. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 166/007 INHIBIT ADS IS NOT CONNECTED - TRANSMIT FAILED A message from the Gantry CPU can not be sent to ADS because the ADS is not connected or powered down. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 167/001 HALT PDU NODE NOT STARTED The Power Distribution Unit (PDU) node did not start. At power-up, the PDU node sends an acknowledgment (which can be different from the first heartbeat signal) to Gantry CPU. If the PDU node does not send an acknowledgment, the Gantry CPU creates this error. 1. Reboot the system from the X-ray Console and perform a compression motion before a complete Gantry boot. 2. If the problem persists, change the PDU Board (Firmware or Hardware problem) (see Job Card D/R A191 - PDU Board on page 1137). 3. If the problem persists, check CAN bus. 167/002 HALT PDU NODE NOT RESPONDING The Power Distribution Unit (PDU) node did not send a heartbeat signal. Between two motions, the PDU node sends a Heartbeat signal every second to Gantry CPU. If not, the Gantry CPU creates this error. During lift motion, the lift PDU sends an actual value message regularly in addition to the heartbeat. If not, the Gantry CPU creates this error. Possible FRUs= PDU board, CAN bus 167/003 HALT INTERNAL SOFTWARE ERROR The Gantry CPU received an unknown error code from the Power Distribution Unit (PDU) node. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. Page no. 925 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 167/004 HALT EMCY LINE FAILURE ON COMPRESSION NODE Possible causes: • A stop motion simulation fault occurred. At powerup, in order to ensure that the stop motion line works, the compression board simulates an opening of the stop motion line (like a pressure on the stop motion button). Then, lift, rotation, and compression nodes enter their safety mode and warn the Gantry CPU. After this check, the Gantry CPU simulates a stop motion as well. Again, the lift, rotation and compression nodes enter their safety mode and warn the Gantry CPU. If one of the nodes does not enter its safety mode, the Gantry CPU creates an error message. • The TP1 connector on the Compression board is closed. Job Card Proceed as follows: 1. Check the error logs. If this error occurs in conjunction with error 161/038, there is a possibility that a jumper exists on the TP1 connector on the Compression board. In this case you must remove the jumper from the TP1 connector on the Compression board. 2. If the TP1 connector is not closed on the Compression board, apply the following rules to determine which board to change: - If no other node responded to the stop command, the Faulty FRU is the Compression Board (simulator is down) or positioner bus (stop motion line is cut). In this case check the Compression board cable connections, and cable. If necessary change the cable. If the cable is fine, change the Compression board D/R A250 page 1323 - If other nodes did respond to the stop command then the fault FRU is the Compression Board (bus connector other hardware or firmware problem). Change the Compression board. 167/005 HALT EMCY STOP LINE ACTIVATED The emergency stop line is activated. Check the Stop button continuity and connector quality routing and continuity of cable W216/W217. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. Chapter 9 Page no. 926 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 167/006 HALT NVRAM CHECKSUM ERROR Possible Cause/Recommended Action Job Card There is an NVRAM checksum error on the Gantry CPU. Reboot the system from the X-ray Console. If the problem persists, contact your OLC. 167/007 HALT EMCY LINE FAIL- Check the error logs. If this error occurs in conjuncURE ON LIFT NODE tion with error 161/036, there is a possibility that a jumper exists on the TP2 connector on the Lift board. In this case you must remove the jumper from the TP2 connector on the Lift board. D/R A210 page 1161 If the TP2 connector is not closed on the Lift board, apply the following rules to determine which board to change: If no other node responded to the stop command: Faulty FRU = Lift Board (simulator is down) or positioner bus (stop motion line is cut). In this case check the Lift board cable connections, and cable. If necessary change the cable. If the cable is fine, change the Lift board. If other nodes did respond to the stop command: Faulty FRUs = Lift Board (bus connector other hardware or firmware problem). Change the Lift board. 167/008 HALT EMCY LINE FAILURE ON ROTATION NODE Check the error logs. If this error occurs in conjunction with error 161/037 or with error 161/043, there is a possibility that a jumper exists on the TP2 connector on the Rotation board. In this case you must remove the jumper from the TP2 connector on the Rotation board. If the TP2 connector is not closed on the Rotation board, apply the following rules to determine which board to change: If no other node responded to the stop command: Faulty FRU = Rotation Board (simulator is down) or positioner bus (stop motion line is cut). In this case check the Rotation board cable connections, and cable. If necessary change the cable. If the cable is fine, change the Rotation board. D/R A221 page 1223 If other nodes did respond to the stop command: Faulty FRUs = Rotation Board (bus connector other hardware or firmware problem). Change the Rotation board. Page no. 927 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category 167/009 ADVISORY Text in Log File or on LCD Possible Cause/Recommended Action INCORRECT GANTRY CONFIGURATION There is currently an incorrect Gantry configuration. The field of view (FOV) setting does not match the paddle sliding position, or the paddle/breast support combination is not correct. Job Card Operator error. No service recommended actions. Chapter 9 Page no. 928 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages 3-8 Error codes from 170/yyy: Bucky Code Category Text in Log File or on LCD Possible Cause/Recommended Action 170/000 INHIBIT GRID NODE ERROR This error is linked to an invalid command sent by Poseidon (exposure time out of range for instance). Job Card 1. Reboot the system from the X-ray Console. 2. If the problem persists, check the CAN bus Poseidon-Bucky. 170/001 DEBUG ONLY GRID NODE ERROR Command not processed because the previous command is being processed. Ignore this error. 170/002 INHIBIT GRID NODE ERROR This error is linked to a system CAN overrun, object lost. 1. Reboot the system from the X-ray Console. 2. If the problem persists, check the overall system CAN bus. 170/003 INHIBIT GRID NODE ERROR This error is due to an invalid PDO length. 1. Reboot the system from the X-ray Console. 2. If the problem persists, check the overall system CAN bus. 3. If the problem persists, change the Bucky and check the mechanical thickness. 170/004 INHIBIT GRID NODE ERROR The Gantry CPU heartbeat was not received. 1. Reboot the system from the X-ray Console. 2. If the problem persists, check whether this failure is reported on other nodes meaning that Gantry CPU does not send system heartbeats. Hence replace Gantry CPU board (re-calibrate the collimator afterwards). 3. If the error 162/007 is raised, check PoseidonStereotix CAN bus. 170/005 DEBUG ONLY GRID NODE ERROR ELE A015 page 579 D/R A190 page 1131 CAL A029 page 1683 ELE A028 page 679 This error is due to a correlation error and is linked to a Bucky step lost error. 1. Reboot the system from the X-ray Console. 2. If the problem persists, change the Bucky and check the mechanical thickness. D/R A255 page 1339 Note: If this error occurs more than five times per month, change the Bucky. ELE A015 page 579 Page no. 929 ERR-SUB-A-003.fm D/R A255 page 1339 Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD Possible Cause/Recommended Action 170/006 DEBUG ONLY GRID NODE ERROR In the case where the exposure time is between 20 ms and 50 ms, the calculation is done using an exposure time of 50 ms. Ignore this error. No action is required. 170/007 INHIBIT Bucky Initialization Failed The Bucky failed to initialize with the Gantry. 1. Reboot the system from the X-ray Console. 2. If the problem persists, remove the carbon cover and check that the Bucky can move. 3. If the problem persists, it could be linked to a mechanical issue, consequently add grease. 4. If the problem persists, change the Bucky and check the mechanical thickness. 170/008 INHIBIT Bucky Step Lost Job Card When this error occurs intermittently it is due to a bucky step loss. When this error occurs frequently and there are grid lines in the X-ray images it is due to a faulty or badly adjusted Bucky connector cable (W310/W313 and W311) located at the sides of the digital detector. 1. Reboot the system from the X-ray Console. 2. If the problem persists and there are grid lines in the X-ray images, do the following with the Bucky connector cable W310/W313: a. Check that the cable connectors are fine. Check that they are not disfigured or have the plastic insulation covering them. b. Check the cable continuity. You can do this by looking for erratic variation in resistance when gently wiggling the cable. c. If the problem persists or this error occurred during wiggling the cable, the cable is faulty. 3. If the problem persists and there are grid lines in the X-ray images, change the Bucky connector cable W311. a. Check that the cable connectors are fine. Check that they are not disfigured or have the plastic insulation covering them. b. Check the cable continuity. You can do this by looking for erratic variation in resistance when gently wiggling the cable. c. If the problem persists or this error occurred during wiggling the cable, the cable is faulty. 4. If the problem persists, change the Bucky and check the mechanical thickness. D/R A255 page 1339 ELE A015 page 579 D/R A255 page 1339 D/R A255 page 1339 D/R A255 page 1339 ELE A015 page 579 Note: If this error occurs more than five times per month change the Bucky. Chapter 9 Page no. 930 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 170/009 INHIBIT Bucky Step Lost 170/010 INHIBIT Bucky Step Lost Possible Cause/Recommended Action Due to either a Bucky step loss or an Optical Fork failure on the Bucky board. Can occur during the GoHome motion of the Bucky, which is usually after an acquisition when the Bucky returns to a start posiD/R A258 tion so it is ready for the next acquisition. page 1347 Possible causes are either an issue with the motor/ drivetrain, the optical fork on the Bucky node, or maybe the 48V power supply from the cables/conD/R A255 nectors going to the Bucky. page 1339 If this error occurs more than five times per month change the Bucky, and send the faulty Bucky back to ELE A015 the repair center. page 579 If the error occurs constantly, proceed as follows: 1. Reboot the system from the X-ray Console. 2. If the problem persists and there are grid lines in the X-ray images, do the following with the Bucky connector cable W310/W313: a. Check that the cable connectors are fine. Check that they are not disfigured or have the plastic insulation covering them. b. Check the cable continuity. You can do this by looking for erratic variation in resistance when gently wiggling the cable. c. If the problem persists or this error occurred during wiggling the cable, the cable is faulty. 3. If the problem persists and there are grid lines in the X-ray images, change the Bucky connector cable W311. a. Check that the cable connectors are fine. Check that they are not disfigured or have the plastic insulation covering them. b. Check the cable continuity. You can do this by looking for erratic variation in resistance when gently wiggling the cable. c. If the problem persists or this error occurred during wiggling the cable, the cable is faulty. 4. If the problem persists, change the Bucky board. 5. If the problem persists, change the Bucky and check the mechanical thickness. Send the faulty Bucky back to the repair center. Page no. 931 ERR-SUB-A-003.fm Job Card Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages 3-9 Error codes from 180/yyy: Stereotix Code Category Text in Log File or on LCD 180/000 HALT STXY NODE ERROR Possible Cause/Recommended Action Job Card CAN overrun, object lost. 1. Unplug and replug the stereotix unit. Reboot the complete system. 2. If the problem persists, replace the stereotix unit. 180/001 HALT STEREOTAXY COMMUNICATION ERROR The Gantry CPU heatbeat was not received. 1. Reboot the system from the X-Ray Console. 2. If the problem persists, then check if this failure is reported on other nodes meaning that Gantry CPU does not send system heartbeats. Hence replace Gantry CPU board (re-calibrate the collimator afterwards). 3. If error 162/007 is raised, check Poseidon-Stereotix CAN bus. 181/000 WARNING STEREOTAXY WARNING: SLIPPAGE ON AXIS X Reboot the system from the X-Ray Console. If the problem persists, then call the OLC. 181/001 WARNING STEREOTAXY WARNING: SKATING ON AXIS Y Reboot the system from the X-Ray Console. If the problem persists, then call the OLC. 181/002 WARNING STEREOTAXY WARNING: SKATING ON AXIS Z Reboot the system from the X-Ray Console. If the problem persists, then call the OLC. 181/003 HALT STEREOTAXY HARDWARE FAILURE Hardware failure with the stereotix EEPROM. STEREOTAXY HARDWARE FAILURE Hardware failure with the stereotix I2C bus. 181/004 HALT D/R A190 page 1131 CAL A029 page 1683 ELE A028 page 679 1. Change the CPU Board on the Stereotactic Positioner (see the Stereotaxy Service Manual). 2. Perform a Calibration of the Stereotactic Positioner (see the Stereotaxy Service Manual). 1. Change the CPU Board or remote display kit on the Stereotactic Positioner (see the Stereotaxy Service Manual). 2. Perform a Calibration of the Stereotactic Positioner (see the Stereotaxy Service Manual). 181/005 Chapter 9 WARNING STEREOTAXY HARDWARE FAILURE Hardware failure with the stereotix LED. 1. Change the CPU Board on the Stereotactic Positioner (see the Stereotaxy Service Manual). 2. Perform a Calibration of the Stereotactic Positioner (see the Stereotaxy Service Manual). Page no. 932 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages Code Category Text in Log File or on LCD 181/006 HALT STEREOTAXY HARDWARE FAILURE 181/007 HALT STEREOTAXY HARDWARE FAILURE Possible Cause/Recommended Action Job Card Hardware failure with the stereotix power. 1. Change the CPU Board on the Stereotactic Positioner (see the Stereotaxy Service Manual). 2. Perform a Calibration of the Stereotactic Positioner (see the Stereotaxy Service Manual). Hardware engine failure with the stereotix A/D converter. 1. Change the CPU Board on the Stereotactic Positioner (see the Stereotaxy Service Manual). 2. Perform a Calibration of the Stereotactic Positioner (see the Stereotaxy Service Manual). 181/008 HALT 181/009 HALT STEREOTAXY NEE- Security Failure: Needle path failure. DLE PATH FAILURE Try to reproduce the defect by playing with the needle path lock button. • If defect is reproducible, the Z-axis trolley is faulty and you must change the Stereotactic Positioner (see the Stereotaxy Service Manual). • If defect it is not reproducible, the faulty FRU is the Stereotactic Positioner CPU board, and you must change the CPU Board on the Stereotactic Positioner (see the Stereotaxy Service Manual). STEREOTAXY FAILURE Security Failure: Power switch failure. 1. Change the CPU Board on the Stereotactic Positioner (see the Stereotaxy Service Manual). 2. Perform a Calibration of the Stereotactic Positioner (see the Stereotaxy Service Manual). 181/010 HALT STEREOTAXY SOFTWARE FAILURE Software failure with the stereotix sequencing. 1. Unplug and replug the stereotix then reboot the system from the X-Ray Console. 2. If the problem persists, replace the stereotix unit. Page no. 933 ERR-SUB-A-003.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN ERR SUB A003 - Gantry Error Messages This page is blank. Chapter 9 Page no. 934 ERR-SUB-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A005 - AWS Error Messages ERR SUB A005 - AWS Error Messages 1 Chapter 9 HOW TO VIEW THE ERROR LOG Errors reported by the AWS software applications are recorded in a common system error log. This common system error log also contains error messages generated by the IDC and Gantry/Generator applications. To view the error log content, right click the AWS Screen background; select Service Tools/Service Desktop/Error Log from the drop-down menu. 2 AWS ERROR MESSAGES TABLE 1 - AWS DIAGNOSTIC ERROR MESSAGES Error Code Error Text Actions (in recommended order) 1 Software failure 2 Software integrity error 3 Communication problem with IDC subsystem Reset IDC and/or restart the Browser (seeRestarting the Browser on page 119). Check cable connection between AWS and IDC). 4 Communication problem with Senographe subsystem Check that Senographe is on. Check cable connection between AWS and Generator. Change Generator Interface Board or change AWS. 6 Communication problem with external network Check network cable connection. Check/change network hub. 7 Communication problem with UPS Check cable connection between AWS and UPS. Try to restart the system. On V3 or V4 Control Stations (U20 or Z400) additionally try adding DB9 Adaptors to the DB9 sockets on the ADS rear panel (see Job Card TSG A012 - Use of DB9 Adaptors to Reduce Intermittent IDC or ADS Communication Errors on page 1029). Change UPS or AWS. 8 Battery low or discharged 10 Failure accessing hardware key None (automatic server restart). Run fsck. Reinstall the software. Charge UPS battery (press the Control Station "on" switch on Generator Cabinet, wait approx. 45 minutes). Change UPS if necessary. Check HW key validity and integrity. Check HW key serial port on AWS. On V3 or V4 Control Stations (U20 or Z400) additionally try adding DB9 Adaptors to the DB9 sockets on the ADS rear panel (see Job Card TSG A012 - Use of DB9 Adaptors to Reduce Intermittent IDC or ADS Communication Errors on page 1029). Change HW key or AWS. 12 DICOM communication prob- The DICOM worklist provider is not DICOM compliant. lem with worklist provider Check the DICOM compatibility with hospital network administrator. Check the DICOM worklist provider declaration parameters. 18 Wrong value received from X Generator Check AWS and generator releases; if not compatible, upgrade system. Page no. 935 ERR-SUB-A-005.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A005 - AWS Error Messages 19 Chapter 9 Wrong value received from IDC Check AWS and IDC releases; if not compatible, upgrade system. Page no. 936 ERR-SUB-A-005.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN ERR SUB A007 - IDC Error Messages ERR SUB A007 - IDC Error Messages 1 Chapter 9 HOW TO VIEW THE ERROR LOG Errors reported by the IDC diagnostic routines are recorded in a common system error log. The common system error log also contains error messages generated by the AWS and Gantry/Generator applications. To view the error log content, right click the AWS Screen background; select Service Tools/Service Desktop/Error Log from the drop-down menu. The most recent error code generated by the IDC can also be viewed on the display on the rear of the IDC computer. 2 IDC DIAGNOSTICS Each time that the IDC sub-system is booted (powered up or reset), it carries out a series of diagnostic self-tests, first under the control of the BIOS, then under software control. As each test is performed, a corresponding code appears on the four-digit green LCD panel at the rear of the IDC Computer. 2-1 BIOS Diagnostic Display While the BIOS tests are running, the LCD displays two blank digits followed a two-digit code corresponding to the current test. If a test detects an error or fails to complete, the tests are halted and the code of the failing test remains displayed. 2-2 • • • • 3 Software Diagnostic Display Three sets of software diagnostics are carried out. While these tests are running, the display shows X000, where X may be 1, 2, or 3. If all tests are completed without failure, the display shows FFFF. If a test fails, the display shows a code in the form XXFF for two seconds. XX is a code corresponding to the failing test. The tests then continue. On completion of the tests after a failure occurs, the display shows F0FF. ERROR DETECTION • • If the IDC halts with a display in the format FFFF, all power-up tests have passed without failure. If the IDC halts with a display in the format --XX, where XX can be any number, a BIOS test has failed. If the problem occurs again after reset, the recommended action is to change the IDC Computer. • If the IDC halts with a display in the format F0FF, a software test has failed. Reset the IDC and watch the LCD display. If the failure is repeated, a code XXFF appears for two seconds. Note the error code XX. Table 1 gives a list of IDC diagnostic error codes, with recommended sequences of actions. Page no. 937 ERR-SUB-A-007.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A007 - IDC Error Messages TABLE 1 - IDC DIAGNOSTIC ERROR CODES Error Code Displayed Actions (in recommended order) FFFF No action; all tests passed. - - XX A BIOS test (code XX) has failed. If the problem persists, change the IDC. FOFF A software test has failed. Reset the IDC and watch the LCD display. Note any error code displayed (XXFF for two seconds). 01, 02, 03 Reset IDC. Restore IDC software. 11, 12, 13, 14, 15, 16, 23, 41, 53, 55 Reset IDC. Change IDC. 21 Change IDC-Conditioner cable. Change Conditioner. Change Detector. 22 Check/top up conditioner coolant. Change conditioner. 24 Change IDC-Senographe serial link cable. 31 Check/change IDC-Detector Power Supply cable. 32 Change Detector Power Supply. 33 Change Detector Power Supply ac cable. Change Detector Power Supply. 40 Check/change IDC-Detector fiber-optic cables. Change Detector. 42 Check/change IDC-Detector fiber-optic cables. 51 Change IDC-Senographe serial link cables. Change Senographe board 400PL2. Change IDC. 52 Error Log Message: I52 detector calibration not optimum Root Cause: The Detector Calibration (Bad Pixel + Gain) on the IDC is not completely performed. Recommended Actions: Peform Job Card CAL A041 - Bad Pixel Calibration on page 1693 and then Job Card CAL A043 - Detector Gain Calibration on page 1697.When performing the Detector Gain calibrations, ensure that in addition to contact mode techniques, perform all the other (Mag and/or Stereotaxy) techniques corresponding to the system options available. 54 Change IDC-Senographe serial link cables. 56 Change IDC-Senographe RT line cables. 60 Check Detector temp./humidity; if OK Change Detector. Chapter 9 Page no. 938 ERR-SUB-A-007.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN ERR SUB A007 - IDC Error Messages Error Code Displayed Actions (in recommended order) 64 Check/change IDC-Conditioner water pipes. Change Conditioner. Change Detector. 66 Repeat calibrations. Change IDC. Page no. 939 ERR-SUB-A-007.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN ERR SUB A007 - IDC Error Messages This page is blank. Chapter 9 Page no. 940 ERR-SUB-A-007.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Diagnostics DIAGNOSTICS CHAPTER 9 Diagnostic information is given in the following modules: - Job Card DIAG A1000 - Gantry Diagnostic on page 943 Job Card DIAG A001 - AWS Sun-VTS Diagnostics on page 977 Job Card DIAG A002 - AWS Ethernet Port Diagnostics on page 987 Job Card DIAG A003 - AWS File System and SCSI Board Diagnostics on page 989 Job Card DIAG A005 - Error Log Retrieval on page 993 Job Card DIAG A010 - No Lift or Rotation Movement on page 1005 Page no. 941 Diagnostics.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Diagnostics This page is blank. Chapter 9 Page no. 942 Diagnostics.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic Job Card DIAG A1000 - Gantry Diagnostic Chapter 9 The Gantry software sends a warning message each time an abnormal situation is detected. This Job Card provides a guide for when the warning message content is not self-sufficient. It is especially useful when the warning message indicates more than one defective FRU. This Job Card gives a set of individual diagnostic procedures (identified as Job Cards), each corresponding to one or several warning codes, as summarized below. 1 GANTRY DIAGNOSTIC JOB CARD SUMMARY JC Number Name JC DIAG A 1001 FOOTSWITCH IS PRESSED page 945 JC DIAG A 1004 LIFT CONTROL FAILURE page 946 JC DIAG A 1005 LIFT CONTROL FAILURE page 946 JC DIAG A 1008 LIFT CONTROL FAILURE page 947 JC DIAG A 1011 LIFT CONTROL FAILURE page 947 JC DIAG A 1012 LIFT CONTROL FAILURE page 948 JC DIAG A 1013 LIFT CONTROL FAILURE page 948 JC DIAG A 1014 LIFT POSITION OVERSHOOT page 948 JC DIAG A 1015 LIFT CONTROL FAILURE page 949 JC DIAG A 1016 LIFT CONTROL FAILURE page 949 JC DIAG A 1017 LIFT CONTROL FAILURE page 950 JC DIAG A 1103 ROTATION CONTROL FAILURE page 950 JC DIAG A 1104 ROTATION CONTROL FAILURE page 950 JC DIAG A 1107 ROTATION CONTROL FAILURE page 951 JC DIAG A 1109 ROTATION CONTROL FAILURE page 951 JC DIAG A 1110 ROTATION CONTROL FAILURE page 952 JC DIAG A 1111 ROTATION CLUTCH FAILURE page 952 JC DIAG A 1112 ROTATION BRAKE DEFECT page 953 JC DIAG A 1113 ROTATION CONTROL FAILURE page 953 JC DIAG A 1114 ROTATION CONTROL FAILURE page 953 JC DIAG A 1115 ROTATION POSITION OVERSHOOT/ROTATION CONTROL FAILURE page 954 JC DIAG A 1116 ROTATION CONTROL FAILURE page 954 JC DIAG A 1117 ROTATION COMMUNICATION FAILURE page 955 JC DIAG A 1118 ROTATION CONTROL FAILURE page 955 JC DIAG A 1201 CONTROL PAD FAILURE page 956 JC DIAG A 1203 COMPRESSION CONTROL FAILURE page 957 JC DIAG A 1205 COMPRESSION CONTROL FAILURE page 957 JC DIAG A 1206 COMPRESSION CONTROL FAILURE page 958 Page no. 943 JC-DIAG-A-1000.fm Page Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic JC Number Chapter 9 Name Page JC DIAG A 1208 COMPRESSION CONTROL FAILURE page 960 JC DIAG A 1212 COMPRESSION BRAKE FAILURE page 960 JC DIAG A 1213 COMPRESSION CONTROL FAILURE page 961 JC DIAG A 1214 COMPRESSION CONTROL FAILURE page 961 JC DIAG A 1215 COMPRESSION CONTROL FAILURE page 962 JC DIAG A 1216 COMPRESSION COMMUNICATION FAILURE page 962 JC DIAG A 1301 CONTROL PAD FAILURE page 963 JC DIAG A 1302 TUBE HEAD CONTROL FAILURE page 965 JC DIAG A 1305 TILT CONTROL FAILURE page 966 JC DIAG A 1401 LIGHT CENTERING FAILURE page 967 JC DIAG A 1402 COLL FRONT/LEFT/RIGHT/REAR BLADE HOMING FAILURE page 967 JC DIAG A 1403 COLLIMATOR FILTER HOMING FAILURE page 968 JC DIAG A 1500 AC MAINS FAILURE page 971 JC DIAG A 1501 JC DIAG A1501 12V DC Generator Voltage Off page 971 JC DIAG A 1502 ACDC MODULE POWER FAILURE page 973 JC DIAG A 1503 OVERCURRENT FAILURE page 974 JC DIAG A 1504 LOW POWER 2 FUSE IS BAD page 975 JC DIAG A 1505 HIGH POWER FUSE IS BAD page 975 JC DIAG A 1506 LOW POWER 1 FUSE IS BAD page 975 JC DIAG A 1507 MAIN CPU FUSE IS BAD page 975 JC DIAG A 1508 MODULE REPORTS POWER FAILURE page 976 JC DIAG A 1509 MODULE REPORTS FAN FAILURE page 976 JC DIAG A 1510 MODULE REPORTS OVER TEMPERATURE page 976 Page no. 944 JC-DIAG-A-1000.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2 GANTRY DIAGNOSTIC JOB CARDS 2-1 JC DIAG A1001 FOOTSWITCH IS PRESSED Diagnostic for: 100/004 error code (CAN code is 0x9006) lift up pedal error 100/005 error code (CAN code is 0x9005) lift down pedal error 100/006 error code (CAN code is 0x9008) decomp pedal error 100/007 error code (CAN code is 0x9007) comp pedal error 102/006 error code (CAN code is 0x5006) lift up pedal error 102/007 error code (CAN code is 0x5005) lift down pedal error 102/008 error code (CAN code is 0x5008) decomp pedal error 102/009 error code (CAN code is 0x5007) comp pedal error If the error is present when the footswitches are connected: • Ensure that nothing is pressing on a footswitch, then reboot the Gantry. • If the message is the same: - Disconnect the left footswitch and reboot the Gantry. - Reconnect the left footswitch, disconnect the right footswitch and reboot the Gantry. - Disconnect both footswitches and reboot the Gantry. The faulty FRU is the footswitch (right or left) present when the error is produced: Lift up pedal if 100/004 or 102/006 Lift down pedal if 100/005 or 102/007 Compression up pedal if 100/006 or 102/008 Compression down pedal if 100/007 or 102/009 If the footswitches are not faulty, change the Lift Board (see Job Card D/R A201 - Lift Board on page 1161). FRUs: Right quad footswitch Left quad footswitch Lift Board Page no. 945 JC-DIAG-A-1000.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2-2 JC DIAG A1004 LIFT CONTROL FAILURE Diagnostic for: 102/001 error code (CAN code is 0x5038) absolute range error • Check the lift potentiometer mechanical movements, connections, and check for secure mounting. • Check the lift potentiometer cable (W203), cable connection to Lift Board J11. • Reconnect the W203 cable connector from Lift Board J11, measure the lift potentiometer resistance continuity on the connector: between pins 1-3, 1-2, 2-3, moving the lift potentiometer shaft manually. • If a fault is found, change the lift potentiometer (see Job Card D/R A204 - Lift Potentiometer on page 1175) and cable. • If the lift potentiometer unit is good, change the Lift Board (see Job Card D/R A201 - Lift Board on page 1161). FRUs: Potentiometer with cable Lift Board 2-3 JC DIAG A1005 LIFT CONTROL FAILURE Diagnostic for: 102/002 error code (CAN code is 0x5010, or 0x500F) speed error • Check the DC level of complementary outputs: A/A complementary, and B/B complementary on the encoder connector: Lift Board J9 for W205. The acceptable level is 5 VDC and 0 VDC. (The signal is 4-phase: A/A complementary, and B/B complementary) • If the DC level is correct, change the Lift Board (see Job Card D/R A201 - Lift Board on page 1161). FRUs: Motor + encoder with cable Lift Board If the Lift Board or motor unit is changed, recalibration is necessary! Chapter 9 Page no. 946 JC-DIAG-A-1000.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2-4 JC DIAG A1008 LIFT CONTROL FAILURE Diagnostic for: 102/005 error code (CAN code is 0x5025) correlation error 102/010 error code (CAN code is 0x5003) optical fork1 error 102/012 error code (CAN code is 0x5004) optical fork2 error • If a correlation error is reported, ensure that the upper and lower optical forks are in the correct positions. • Ensure that the upper optical fork is in the correct position. • Check to see whether the optical fork is covered. If it is, turn the trapezoid screw until the optical fork is not covered. • Recalibrate the lift (see Job Card CAL A031 - Lift Calibration on page 1687). • If the errors persist or a ”Potentiometer out of range” error (102/001 error code, CAN code: 0x5038) is reported during the calibration, check the lift potentiometer, change it if necessary (see Job Card D/R A204 - Lift Potentiometer on page 1175), and start the calibration again. • If the errors persist, check the lift motor and encoder cabling and connections. If any item is found faulty, change the faulty item (see Job Card D/R A205 - Lift Motor on page 1179). If the cabling and connections are good, recalibrate the Lift Board (see Job Card CAL A031 - Lift Calibration on page 1687). • If the errors persist, change the Lift Board (see Job Card D/R A201 - Lift Board on page 1161). FRUs: Potentiometer with cable Lift Board Motor + encoder with cable 2-5 JC DIAG A1011 LIFT CONTROL FAILURE Diagnostic for: 102/015 error code (CAN code is 0x5026) overcurrent error • Inspect the lift belt. If it is broken or not tight enough, it must be changed. • Check the motor cable (between the coil wires, and between the control wires and the ground wires), then measure the motor coil resistance). • If the cable is broken, change the motor unit (see Job Card D/R A205 - Lift Motor on page 1179). • If the cable and the motor are good, change the Lift Board (see Job Card D/R A201 - Lift Board on page 1161). • If the Lift Board is good, change the gas spring for lift compensation (see Job Card D/R A206A - Lift Gas Spring on page 1183). FRUs: Belt for lift compensation Lift Board Motor + encoder with cable Gas spring Page no. 947 JC-DIAG-A-1000.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2-6 JC DIAG A1012 LIFT CONTROL FAILURE Diagnostic for: 102/013 error code (CAN code is 0x6004) overspeed error • Check the error logs. If this error occurs at the same time than as error 102/014 "lift under speed", change the lift gas spring. See Job Card D/R A206A - Lift Gas Spring on page 1183. • If the problem persists, check the DC level of complementarity outputs: A/A complementary, and B/B complementary on the encoder connector: Lift Board J9 for W205. The acceptable levels are 5 VDC and 0 VDC. (The signal is 4-phase: A/A complementary, and B/B complementary) • If the DC level is good, change the Lift Board (see Job Card D/R A201 - Lift Board on page 1161). FRUs: Lift Board Motor + encoder with cable Gas spring If the Lift Board or motor unit is changed, recalibration is necessary! 2-7 JC DIAG A1013 LIFT CONTROL FAILURE Diagnostic for: 102/004 error code (CAN code is 0xxxxx) lift low speed error 102/014 error code (CAN code is 0x6005) lift low speed error 102/024 error code (CAN code is 0xxxxx) uncontrolled lift motion error • Check the motor cable (between the coil wires, and between the control wires and the ground wires), then measure the motor coil resistance. • If the cable is broken, change the motor unit with encoder and cables (see Job Card D/R A205 - Lift Motor on page 1179). • If the cable and the motor are good, change the Lift Board (see Job Card D/R A201 - Lift Board on page 1161). • If the Lift Board is good change the gas spring for lift compensation (see Job Card D/R A206A - Lift Gas Spring on page 1183). FRUs: Lift Board Motor + encoder with cable Gas spring 2-8 JC DIAG A1014 LIFT POSITION OVERSHOOT Diagnostic for: 102/030 error code (CAN code is 0x6006) position error 102/031 error code (CAN code is 0x6007) deceleration error • Change the Lift Board (see Job Card D/R A201 - Lift Board on page 1161). • If the Lift Board is good, change the gas spring for lift compensation (see Job Card D/R A206A - Lift Gas Spring on page 1183). Chapter 9 Page no. 948 JC-DIAG-A-1000.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic FRUs: Lift Board Gas spring 2-9 JC DIAG A1015 LIFT CONTROL FAILURE Diagnostic for: 101/004 error code (CAN code is 0x9002) valid motion error 1. Perform a lift calibration (see Job Card CAL A031 - Lift Calibration on page 1687). 2. If the error persists, inspect the cables listed below. If you find any damage in a cable or connector, change the cable. If no defect can be seen, change the cables in the following order: - W213 - POS-BUS 1 cable for Lift to Rotation - W304A cable for paddle detector - W304B cable for paddle detector - W314 Sys Pos Bus cable - W311 - POS-BUS 2 cable for Bucky board 3. If the error persists, change the Lift Board (see Job Card D/R A201 - Lift Board on page 1161). 4. If the error persists, change the PL 103 CPU Board (see Job Card D/R A190 - Gantry CPU Board on page 1131). FRUs: Motor + encoder with cable Lift Board W314 Sys Pos Bus cable W304A cable for paddle detector W304B cable for paddle detector W311 - POS-BUS 2 cable for Bucky board W213 - POS-BUS 1 cable for Lift to Rotation Nephtys Gantry CPU 2-10 JC DIAG A1016 LIFT CONTROL FAILURE Diagnostic for: 102/040 error code (CAN code is 0x8210) invalid PDO length • Change the Lift Board (see Job Card D/R A201 - Lift Board on page 1161). • If the error persists, change the Gantry CPU Board (see Job Card D/R A190 - Gantry CPU Board on page 1131). • If changing the CPU solved the problem, put back the original Lift Board (see Job Card D/R A201 Lift Board on page 1161). FRUs: Lift Board Nephtys Gantry CPU Page no. 949 JC-DIAG-A-1000.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2-11 JC DIAG A1017 LIFT CONTROL FAILURE Symptom: when the arm is raised to an upper position, the movement is slow and can even stop after several up and down movements. • Change the Gas Spring (see Job Card D/R A206A - Lift Gas Spring on page 1183). 2-12 JC DIAG A1103 ROTATION CONTROL FAILURE Diagnostic for: 112/001 error code (CAN code is 0x5038) absolute range error • Check the W220 potentiometer cable and J11 connection visually. • Power off the Gantry. Moving the rotation potentiometer shaft by hand, measure the rotation potentiometer resistance continuity between pins1-3, 1-2, and 2-3. • If the result of the measurements is not acceptable, change the rotation potentiometer (see Job Card D/R A227 - Rotation Potentiometer on page 1239). • If the rotation potentiometer is good, power on the Gantry and check the voltage between the center pin of the rotation potentiometer connector and ground. The following values must be obtained, according to the arm position: - Arm at +180°; V = 2.825 V ±0.05 V DC - Arm at 0°; V = 1.65 V ±0.05 V DC - Arm at -165°; V = 0.606 V ±0.05 V DC • If the voltage check is not good, turn the rotation potentiometer wheel to obtain the values specified. If this adjustment fails (voltages inconsistent with the position of the wheel), change the Rotation Board (Job Card D/R A221 - Rotation Board on page 1223). • If the voltage check is good, change the Rotation Board (Job Card D/R A221 - Rotation Board on page 1223). FRUs: Pot+cable Rotation Board 2-13 JC DIAG A1104 ROTATION CONTROL FAILURE Diagnostic for: 112/002 error code (CAN code is 0x5010) coder signal error • Check the encoder cable (W205) and its J9 connection on the Rotation Board. • If the cable is not damaged, and the connection is good, change the Rotation Board (Job Card D/R A221 - Rotation Board on page 1223). • If the error persists, change the motor+encoder unit with cables (see Job Card D/R A228 - Rotation Motor on page 1243). FRUs: Rotation Board Mot+encoder with cable Chapter 9 Page no. 950 JC-DIAG-A-1000.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2-14 JC DIAG A1107 ROTATION CONTROL FAILURE Diagnostic for: 112/005 error code (CAN code is 0x5025) correlation error • Check the rotation motor and encoder cabling, and connections. • Recalibrate the Rotation Board (see Job Card CAL A021 - Arm Rotation Calibration on page 1679). If the ”Potentiometer out of range” error appears during the calibration, check the rotation potentiometer. Change it if necessary (see Job Card D/R A227 - Rotation Potentiometer on page 1239), and start the calibration again. • If the rotation potentiometer unit is good and the error is still present, change the Rotation Board (Job Card D/R A221 - Rotation Board on page 1223). • If the error persists, change the rotation motor and encoder (see Job Card D/R A228 - Rotation Motor on page 1243). FRUs: Rotation Board Mot+encoder with cable Pot+cable 2-15 JC DIAG A1109 ROTATION CONTROL FAILURE Diagnostic for: 112/010 error code (CAN code is 0x5004) optical fork error • First check whether the optical fork has in fact been reached: • If it has been reached, rotate the arm manually by moving the timing belt on the worm gear. • Check for play in the gearbox and for tightness of the timing belt. Recalibrate the Rotation Board (see Job Card CAL A021 - Arm Rotation Calibration on page 1679), and try the movement again. • If the ”Potentiometer out of range” error appears during the calibration, check the potentiometer. Change it if necessary (see Job Card D/R A227 - Rotation Potentiometer on page 1239), and start the calibration again. • If the problem is still present, change the Rotation Board (Job Card D/R A221 - Rotation Board on page 1223). • If optical fork is not reached: - Check the optical fork cable and connections. - If the cable and connections are good, change the optical fork. • If the error persists, recalibrate the Rotation Board (see Job Card CAL A021 - Arm Rotation Calibration on page 1679). • If the error persists, change the rotation motor and encoder cables (see Job Card D/R A228 - Rotation Motor on page 1243). FRUs: Rotation Board Mot+encoder with cable Pot+cable Optical fork + cables Page no. 951 JC-DIAG-A-1000.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2-16 JC DIAG A1110 ROTATION CONTROL FAILURE Diagnostic for: 112/014 error code (CAN code is 0x5026) overcurrent error • Check the motor cable (measure resistance between the motor coil outlet wires, and between the control wires and the ground wire). • If the cable is broken, change the rotation motor+encoder unit with cable (see Job Card D/R A228 Rotation Motor on page 1243). • If the cable and the motor unit are ok, change the Rotation Board (Job Card D/R A221 - Rotation Board on page 1223). • If the error persists, change the rotation gas spring (see Job Card D/R A230 - Rotation Gas Spring on page 1251). FRUs: Rotation Board Mot+encoder with cable Gas spring for rotation comp 2-17 JC DIAG A1111 ROTATION CLUTCH FAILURE Diagnostic for: 112/044 error code (CAN code is 0x500E) clutch error • Check the clutch cable (W221 and W218) and connectors visually, then check the DS 6 LED on the Rotation Board: - It must be out (not lit) in rotation mode. - It must be lit in angulation mode clutch is active. • Check the clutch status visually, with the arm not in angulation position. If it is not correct, move the rotation arm to 0°, reboot the Gantry. • If the error persists, power off the Gantry and disconnect cable W221 from J7 of the Rotation Board, and measure the clutch resistance on the cable connector. The nominal resistance value is 15 ohm +/-1 ohm. - If the resistance is out of these limits, change the clutch and cables (see Job Card D/R A222 Clutch and Cable on page 1227). - If the measured resistance is acceptable, change the Rotation Board (Job Card D/R A221 - Rotation Board on page 1223). FRUs: Clutch +cable Rotation Board Chapter 9 Page no. 952 JC-DIAG-A-1000.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2-18 JC DIAG A1112 ROTATION BRAKE DEFECT Diagnostic for: 112/008 error code (CAN code is 0x500D) brake error • Check the brake cable (W219) and connector (J6) visually, then check the DS 5 LED on the Rotation Board: - It must be not lit in stop mode - It must be lit in rotation mode (the brake is active) • Power off the Gantry, and disconnect cable W19 from J6 of the Rotation Board, Measure the brake resistance on the cable connector. - The nominal resistance value is 20 ohm +/-2 ohm. If the resistance is out of these limits, change the brake (see Job Card D/R A229 - Rotation Brake on page 1247). - If the measured resistance is acceptable, change the Rotation Board (Job Card D/R A221 - Rotation Board on page 1223). FRUs: Brake for rotation Rotation Board 2-19 JC DIAG A1113 ROTATION CONTROL FAILURE Diagnostic for: 112/011 error code (CAN code is 0x6004) overspeed error • Check the encoder cable (W205) and its connection (J9) on the Rotation Board. • If the cable is damaged, change the motor + encoder with cables (see Job Card D/R A228 - Rotation Motor on page 1243). • If J9 is damaged, change the Rotation Board (Job Card D/R A221 - Rotation Board on page 1223). • If the cable is not damaged, and the connection is good, change the Rotation Board (Job Card D/R A221 - Rotation Board on page 1223). • If the error persists, change the rotation motor+encoder unit with cables (see Job Card D/R A228 Rotation Motor on page 1243). FRUs: Rotation Board Mot+encoder with cable 2-20 JC DIAG A1114 ROTATION CONTROL FAILURE Diagnostic for: 112/012 error code (CAN code is 0x6005) underspeed error • Change the Rotation Board (Job Card D/R A221 - Rotation Board on page 1223). • If the error persists, change the rotation gas spring (see Job Card D/R A230 - Rotation Gas Spring on page 1251). FRUs: Rotation Board Gas spring for rotation comp Page no. 953 JC-DIAG-A-1000.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2-21 JC DIAG A1115 ROTATION POSITION OVERSHOOT/ROTATION CONTROL FAILURE Diagnostic for: 112/029 error code (CAN code is 0x6006) position error 112/030 error code (CAN code is 0x6007) deceleration error • Change the Rotation Board (Job Card D/R A221 - Rotation Board on page 1223). • If the error persists, change the rotation gas spring (see Job Card D/R A230 - Rotation Gas Spring on page 1251). FRUs: Rotation Board Gas spring for rotation comp 2-22 JC DIAG A1116 ROTATION CONTROL FAILURE Diagnostic for: 111/004 error code (CAN code is 0x9002) valid motion error • Inspect the cables listed below. If you find any damage in a cable or connector, change the cable or the Rotation Board (Job Card D/ R A221 - Rotation Board on page 1223). If no defect can be seen, change the cables in the following order: - W213 - POS-BUS 1 cable for Lift to Rotation - W304A cable for paddle detector - W304B cable for paddle detector - W314 Sys Pos Bus cable - W311 - POS-BUS 2 cable for Bucky board • If the error persists, change the Rotation Board (Job Card D/R A221 - Rotation Board on page 1223). • If the error persists, change the PL 103 CPU Board (see Job Card D/R A190 - Gantry CPU Board on page 1131). FRUs: Motor + encoder with cable Rotation Board W314 Sys Pos Bus cable W304A cable for paddle detector W304B cable for paddle detector W311 - POS-BUS 2 cable for Bucky board W213 - POS-BUS 1 cable for Lift to Rotation Nephtys Gantry CPU Chapter 9 Page no. 954 JC-DIAG-A-1000.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2-23 JC DIAG A1117 ROTATION COMMUNICATION FAILURE Diagnostic for: 112/039 error code (CAN code is 0x8210) invalid PDO length • Change the Rotation Board (Job Card D/R A221 - Rotation Board on page 1223). • If the error persists, change the PL 103 CPU Board (see Job Card D/R A190 - Gantry CPU Board on page 1131). • If changing the CPU Board solved the error, put back the original Rotation Board (Job Card D/R A221 - Rotation Board on page 1223). FRUs: Rotation Board Nephtys Gantry CPU 2-24 JC DIAG A1118 ROTATION CONTROL FAILURE Diagnostic for: 112/045 error code (CAN code is 0x5028) optical fork reached error • Inspect the optical fork cable. If the optical fork cable seems to be good, change the optical fork (see Job Card D/R A223 - Rotation Optical Fork on page 1231). • If the error persists, put back the original optical fork and change the Rotation Board (Job Card D/R A221 - Rotation Board on page 1223). • Reboot the Gantry. If the error is still present, put back the original Rotation Board as it is good (Job Card D/R A221 - Rotation Board on page 1223). Then change the CPU Board (see Job Card D/R A190 - Gantry CPU Board on page 1131). FRUs: Rotation Board Nephtys Gantry CPU Optical fork + cable Page no. 955 JC-DIAG-A-1000.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2-25 JC DIAG A1201 KEYPAD FAILURE Diagnostic for: 120/001 error code (CAN code is 0x9016) lift up pressed 120/002 error code (CAN code is 0x9017) lift up pressed 120/003 error code (CAN code is 0x9018) lift down pressed 120/004 error code (CAN code is 0x9019) lift down pressed 120/005 error code (CAN code is 0x901A) rot left pressed 120/006 error code (CAN code is 0x901B) rot left pressed 120/007 error code (CAN code is 0x901C) rot right pressed 120/008 error code (CAN code is 0x901D) rot right pressed 120/009 error code (CAN code is 0x9020) CC pressed 120/010 error code (CAN code is 0x901E) MLO left pressed 120/011 error code (CAN code is 0x901F) MLO right pressed 122/009 error code (CAN code is 0x5016) lift up error 122/010 error code (CAN code is 0x5017) lift up error 122/011 error code (CAN code is 0x5018) lift down error 122/012 error code (CAN code is 0x5019) lift down error 122/013 error code (CAN code is 0x501A) rot left error 122/014 error code (CAN code is 0x501B) rot left error 122/015 error code (CAN code is 0x501C) rot right error 122/016 error code (CAN code is 0x501D) rot right error 122/017 error code (CAN code is 0x5020) CC error 122/018 error code (CAN code is 0x501E) MLO error 122/019 error code (CAN code is 0x501F) MLO error • Ensure that nothing is pressing on any keypad button, then reboot the Gantry. • If the same message appears: - Check the keypad cable and connections. If the cable is faulty, change it. - Disconnect the keypad and connect another of the installed keypads in its place, then reboot the Gantry. If the keypad is found to be faulty, change it. - Change the Compression Board (see Job Card D/R A250 - Compression Board on page 1323). FRUs W305 cable for keypad Handle keypad PL305 Compr Board Chapter 9 Page no. 956 JC-DIAG-A-1000.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2-26 JC DIAG A1203 COMPRESSION CONTROL FAILURE Diagnostic for: 122/003 error code (CAN code is 0x500F or 0x5010) speed error • Check the encoder cable (W302) and its J4 connection on the Compression Board. • If the cable is not damaged and the connection is good, change the Compression Board (see Job Card D/R A250 - Compression Board on page 1323). • If the error persists, change the compression motor+encoder unit with cables (see Job Card D/R A244 - Compression Motor with Encoder and Compression Belt on page 1297). FRUs: Compression Board Motor + Encoder with cable 2-27 JC DIAG A1205 COMPRESSION CONTROL FAILURE Diagnostic for: 122/005 error code (CAN code is 0x5025) correlation error Error name: correlation error. • Check that the compression timing belt is not loose or broken. If necessary, tighten or change the compression timing belt. • If the error persists, check the incremental encoder cable (W302) and its connection on the Compression Board (J4). - If the W302 cable is broken, change the Compression Motor and Encoder (see Job Card D/R A244 - Compression Motor with Encoder and Compression Belt on page 1297). or - If the J4 connector is broken change the Compression Board (see Job Card D/R A250 - Compression Board on page 1323). • If the error persists, check the potentiometer cable (W303) and its connection on the Compression Board (J6). - If the W3023 cable is broken, change the Compression Motor and Encoder (see Job Card D/R A244 - Compression Motor with Encoder and Compression Belt on page 1297). or - If the J6 connector is broken change the Compression Board (see Job Card D/R A250 - Compression Board on page 1323). • If the error persists, do the following: Determine the Compression Potentiometer type (Type 1, Type 2 or Type 3) in the system. Type 1 Type 2 Page no. 957 JC-DIAG-A-1000.fm Type 3 Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic Check the potentiometer resistance between pins 1-2, 1-3, and 2-3. The acceptable resistances between the pins are summarized in the table below. Resistance on Type 1 or Type 2 Compression Potentiometer Resistance on Type 3 Compression Potentiometer Pins 1-3 (Resistance 1) 0.9 kOhm to 1.1 kOhm 9 kOhm to 11 kOhm Pins 1-2 (Resistance 2) 0 kOhm to 1.1 kOhm 0 kOhm to 11 kOhm Pins 2-3 (Resistance 3) 0 kOhm to 1.1 kOhm 0 kOhm to 11 kOhm Resistance 2 + Resistance 3 must be between 0.9 kOhm to 1.1 kOhm 9 kOhm to 11 kOhm If the measured resistance is not between the excepted limits, change the Compression Potentiometer (see Job Card D/R A243 - Compression Potentiometer and Cable on page 1289). Note: The new Compression Potentiometer ordered will be a Type 3 Compression Potentiometer. • If the error persists, check that the potentiometer screw runs normally as the trolley moves. If the potentiometer screw does not move normally, change the Compression Potentiometer (see Job Card D/R A243 - Compression Potentiometer and Cable on page 1289). • If the error persists, change the compression motor and encoder (see Job Card D/R A244 - Compression Motor with Encoder and Compression Belt on page 1297). • If the error persists, change the Compression Board (see Job Card D/R A250 - Compression Board on page 1323). FRUs: Pot+cable Mot+Enc with cable Timing belt Compression Board Recalibration is necessary if the Compression Board or the potentiometer is changed. 2-28 JC DIAG A1206 COMPRESSION CONTROL FAILURE Diagnostic for: 122/006 error code (CAN code is 0x502B) step lost error 122/007 error code (CAN code is 0x6004) overspeed error. • First make a careful visual check of the mechanical parts: worm gear, upper (screw) brake, timing belt, motor unit. • If no mechanical defect is detected: - Check the brake air gap. The gap must be 0.2 mm for correct operation. - Check the incremental encoder cable (W302) and its connection on the Compression Board (J4). • Check the brake cable (W309) and brake coils by measuring the brake resistance. The resistance value must be 192 ohm (+/-10 ohm). If it is out of these limits, change the brake and cables (see Job Card D/R A246 - Manual Compression Brake on page 1301). • If the error persists, remove power from the Compression Board. Apply 48 VDC on the brake cable connector (check polarity!), then try to move the mechanics manually by pulling on the timing belt. - If you cannot move by hand, first oil the mechanics. Chapter 9 Page no. 958 JC-DIAG-A-1000.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic - If you cannot move by hand, change the brake. - If you still cannot move by hand, check the compression mechanism again for mechanical defects • If you can move the timing belt by hand but the "step lost" error is still reported, change the compression motor and encoder. See Job Card D/R A244 - Compression Motor with Encoder and Compression Belt on page 1297. • If the "step lost" error is still reported, change the Compression Board (see Job Card D/R A250 Compression Board on page 1323). FRUs: Compression Board Motor +Encoder with cable Compression current-off brake Page no. 959 JC-DIAG-A-1000.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2-29 JC DIAG A1208 COMPRESSION CONTROL FAILURE Diagnostic for: 122/008 error code (CAN code is 0x5026) overcurrent error • First make a visual check of the motor cabling and its connection to the Compression Board. • Disconnect the cable W301 from connector J3. - Check on the cable connector for a short circuit. If you find one, change the compression motor + encoder + cables (see Job Card D/R A244 - Compression Motor with Encoder and Compression Belt on page 1297). - Measure the motor coil impedances. The impedances must measure 2 ohm between the blue and pink wires, 2 ohm between the yellow and red wires. If not, change the motor + encoder + cables(see Job Card D/R A244 - Compression Motor with Encoder and Compression Belt on page 1297). • If the error persists, change the Compression Board (see Job Card D/R A250 - Compression Board on page 1323). Check the movement. • If the error persists, change the compression motor unit (see Job Card D/R A244 - Compression Motor with Encoder and Compression Belt on page 1297). FRUs: Compression Board Motor +Encoder with cable 2-30 JC DIAG A1212 COMPRESSION BRAKE FAILURE Diagnostic for: 122/020 error code (CAN code is 0x500D) brake error • Check the B303 screw brake cable (W309) and brake coils by measuring the brake resistance. The nominal resistance value is 192 ohm (+/-10 ohm). If the resistance values are out of these limits change the brake and cables (see Job Card D/R A247 - Motorized Compression Brake on page 1309). • Check the connector J5 on the Compression Board for damage. If damage is found, change the Compression Board (see Job Card D/R A250 - Compression Board on page 1323). • Check the compression brake cable (W318) and brake coils by measuring the brake resistance. The nominal resistance value is 230 ohm (+/-10 ohm). If the resistance is out of these limits, change the brake and cables (see Job Card D/R A246 - Manual Compression Brake on page 1301). • If the error persists, change the Compression Board (see Job Card D/R A250 - Compression Board on page 1323). FRUs: Compression brake+cable Screwbrake +cable Compression Board Chapter 9 Page no. 960 JC-DIAG-A-1000.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2-31 JC DIAG A1213 COMPRESSION CONTROL FAILURE Diagnostic for: 122/043 error code (CAN code is 0x502C) Force sensor error • First measure the frequency on pin 3 of Compression Board connector J10. The nominal value is 2 kHz to 20 kHz, with a 5 VDC amplitude square waveform. • If no signal can be measured: - First change cable W304. - If still no signal can be detected, change cable W304b. - If still no signal can be detected, change the PL304 paddle detector board. - If still no signal can be detected, change the compression force sensor (see Job Card D/R A248 Force Sensor on page 1313). - If still no signal can be detected, change the Compression Board (see Job Card D/R A250 - Compression Board on page 1323). • If the signal is detected but the measured frequency is out of the specified limits: - First change the compression force sensor (see Job Card D/R A248 - Force Sensor on page 1313). - If the frequency is still incorrect, change the PL304 paddle detector board. • If the measured signal is good and within the specified limits, but the error is still reported, change the Compression Board. See Job Card D/R A250 - Compression Board on page 1323. FRUs: Force sensor W304a cable W304b cable PL304 Paddle holder board Compression Board 2-32 JC DIAG A1214 COMPRESSION CONTROL FAILURE Diagnostic for: 122/002 error code (CAN code is 0x5038) absolute range error Error name: potentiometer range error • First check that the potentiometer screw is not broken. If it is, change the potentiometer and cable (see Job Card D/R A243 - Compression Potentiometer and Cable on page 1289). • Check that the potentiometer cable (W303) is not damaged. If it is, change the potentiometer and cable (see Job Card D/R A243 - Compression Potentiometer and Cable on page 1289). • If the cable is good, measure resistance between pins 1-2, 1-3, and 2-3 while moving the potentiometer steel wire. - If the resistance does not change linearly in accordance with movement of the steel wire, or the value of the potentiometer is not equal to its nominal value, change the potentiometer and cable. See Job Card D/R A243 - Compression Potentiometer and Cable on page 1289. • If the error persists, try to recalibrate the Compression Board. See Job Card CAL A048 - Calibration of Compression Force Sensor on page 1709 and Job Card CAL A050 - Compression Thickness Calibration on page 1721). - If the calibration fails, change the Compression Board (see Job Card D/R A250 - Compression Board on page 1323). Page no. 961 JC-DIAG-A-1000.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic FRUs: Compression Board Pot+cable 2-33 JC DIAG A1215 COMPRESSION CONTROL FAILURE Diagnostic for: 121/004 error code (CAN code is 0x9002) valid motion error Error name: no valid line Inspect the cables listed below. If you find any damage in a cable or connector, change it. Check the cables in the following order: - W213 - POS-BUS 1 cable for Lift to Rotation; - W304A cable for paddle detector. - W304B cable for paddle detector. - W314 Sys Pos Bus cable. - W311 - POS-BUS 2 cable for Bucky board; If the error persists, change the Compression Board (see Job Card D/R A250 - Compression Board on page 1323). If the error persists, change the Gantry CPU Board (see Job Card D/R A190 - Gantry CPU Board on page 1131). FRUs: Compression Board W314 Sys Pos Bus cable W304A cable for paddle detector W304B cable for paddle detector W311 - POS-BUS 2 cable for Bucky board W213 - POS-BUS 1 cable for Lift to Rotation Nephtys Gantry CPU 2-34 JC DIAG A1216 COMPRESSION COMMUNICATION FAILURE Diagnostic for: 122/040 error code (CAN code is 0x8210) invalid PDO length • Change the Compression Board (see Job Card D/R A250 - Compression Board on page 1323). • If the error persists, change the CPU Board (see Job Card D/R A190 - Gantry CPU Board on page 1131). If changing the CPU board solved the problem, put back the original Compression Board (see Job Card D/R A250 - Compression Board on page 1323). FRUs: Compression Board Nephtys Gantry CPU 2-35 JC DIAG A1217 COMPRESSION CONTROL FAILURE Diagnostic for: 122/021 error code (CAN code is 0x503D) force sensor range error This error is reported when the value of the compression force is out of the -50% to +20% calibrated Chapter 9 Page no. 962 JC-DIAG-A-1000.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic force tolerance range. For example, if the force sensor is calibrated in the 0 N to 300 N range, the range limits are: -150 N and 360 N). • First, check whether this high force is applied. If not, recalibrate the force sensor. • If the calibration succeeds: - If this error is not reported after a few compression cycles, the problem is corrected. - If this error is still reported, check for a mechanical jam. If found, change the faulty unit. - If this error is still reported but there is no mechanical jam, check on the CAN trace to see whether the compression force changes rapidly. If it does, change the compression force sensor. - If this error is still reported, change the PL304 paddle detector board. - If the error is still reported, change the compression board. • If the calibration does not succeed: First measure the frequency on pin 3 of the Compression Board connector J10 (the nominal value is 2-20 kHz, with 5 VDC amplitude square waveform). - If no signal is detected, or the signal is out of these limits, continue with JC DIAG A1213 COMPRESSION CONTROL FAILURE on page 961. - If the frequency is present, but does not change when the applied force increases. - First change the compression force sensor. - If the frequency still does not change with the applied force, change the PL304 paddle detector board. - If the frequency still does not change with the applied force, change the paddle holder unit. - If the measured signal is good, and changes correctly, but you still cannot calibrate the node, change the Compression Board. 2-36 JC DIAG A1301 CONTROL KEYPAD FAILURE Diagnostic for: 130/001 error code (CAN code is 0x9016) 130/002 error code (CAN code is 0x9017) 130/003 error code (CAN code is 0x9018) 130/004 error code (CAN code is 0x9019) 130/005 error code (CAN code is 0x901A) 130/006 error code (CAN code is 0x901B) 130/007 error code (CAN code is 0x901C) 130/008 error code (CAN code is 0x901D) 130/011 error code (CAN code is 0x901E) 130/012 error code (CAN code is 0x901F) 130/013 error code (CAN code is 0x9020) 130/014 error code (CAN code is 0x9021) 132/003 error code (CAN code is 0x5016) 132/004 error code (CAN code is 0x5017) 132/005 error code (CAN code is 0x5018) 132/006 error code (CAN code is 0x5019) 132/007 error code (CAN code is 0x501A) 132/008 error code (CAN code is 0x501B) Page no. 963 JC-DIAG-A-1000.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 132/009 error code (CAN code is 0x501C) 132/010 error code (CAN code is 0x501D) 132/025 error code (CAN code is 0x501E) 132/026 error code (CAN code is 0x501F) 132/027 error code (CAN code is 0x5020) Ensure that nothing is pressing on any keypad button, then reboot the Gantry. If the same message appears: - Check the keypad cable and connections. If the cable is faulty, change it. - Disconnect the keypad and connect another of the installed keypads in its place, then reboot the Gantry. If the keypad is found to be faulty, change it. - If the error persists, change the Tube Tilt Board (see Job Card D/R A266 - Tube Tilt Board on page 1365). FRUs: Tube head keypad PL404 Tube Tilt Board W407 cable for keypad Chapter 9 Page no. 964 JC-DIAG-A-1000.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2-37 JC DIAG A1302 TUBE HEAD CONTROL FAILURE Diagnostic for: 130/010 error code (CAN code is 0x502A) Tube tilt initialization failure 132/012 error code (CAN code is 0x502B) Tube tilt step lost 057/001 error code (no CAN code) Arm fatal error Perform the checks listed below step by step. Try the tube tilt after every step. 1. Check that there is no interaction between the HV cable and the Tube Head covers (1). 1 Check that the HV cable length is sufficient to allow tube movement. Disconnect the HV cable, and try the tube tilt without it. If there is any interaction that restricts the movement of the Tube Tilt Mechanism adjust the positioning of the HV cable to stop this interaction. 2. Check that there is no interaction between the HV cable support bracket and the frame top (2) when tilting the tube. If there is any interaction that restricts the movement of the Tube Tilt Mechanism, adjust the positioning of the HV Cable support bracket to stop this interaction. 3. Extract the coupling pin on the Tube Head (3) and check the tube can move without effort. 4. Check there is no friction between frame and spectral wheel support (on each side) (4). 2 3 4 Page no. 965 JC-DIAG-A-1000.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 5. If the error persists after the steps above, remove the top plate of the tube (5) then try to turn the motor shaft (6) by hand. The movement of the motor shaft is either easy or difficult: 5 If the manual movement of the motor shaft is easy: - Check the motor connection and optical fork connection. - Check the optical fork mask. - If all checked parts are good, change the optical fork. - If the error persists, change the tube tilt board (see Job Card D/R A266 - Tube Tilt Board on page 1365) - If the error persists, change the tube tilt motor (see Job Card D/R A265 - Tilt Motor and Drive Assembly on page 1361) 6 If the manual movement of the motor shaft is difficult: - Remove the X-ray tube. Check the mechanical links, and ensure that critical mechanical parts are properly greased. Reinstall the X-ray tube. - If the error persists, change the tube tilt mechanism assembly (without motor) (see Job Card D/R A265 - Tilt Motor and Drive Assembly on page 1361). FRUs: Tube Tilt Board Sensor+Cable Tube tilt motor + cable 2-38 JC DIAG A1305 TILT CONTROL FAILURE Diagnostic for: 132/028 error code (CAN code is 0x5026) overcurrent error • First make a visual check of the motor cabling and the connection to the tilt board. • Disconnect cable W404 fromTilt Board connector J3. Check for short circuits between the pins of the cable connector. • Measure the motor coil impedances. The impedance must measure 2 ohm between the blue and pink wires, and 2 ohm between the yellow and red wires. • If the measured resistance is good, change the tube tilt board (see Job Card D/R A266 - Tube Tilt Board on page 1365) and check the movements. • If the error persists change the Tilt Motor unit (see Job Card D/R A265 - Tilt Motor and Drive Assembly on page 1361). FRUs: Tube Tilt Board Tube tilt motor + cable Chapter 9 Page no. 966 JC-DIAG-A-1000.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2-39 JC DIAG A1401 LIGHT CENTERING FAILURE (COLL 12 V LAMP POWER FAILURE) Diagnostic for: Lamp cannot be switched on. 142/001 error code (CAN code is 0xA050) 1. If the centering light cannot be switched on, check for error 142/001 in the error log. If the error 142/ 001 is not present, the faulty FRU is the Collimator Light Assembly, which you must change. See Job Card D/R A288 - Collimator Lamp on page 1383. 2. If the error 142/001 is present, place a jumper at TP1 on the DC-DC board to force 12 V power module on. Reboot the system then check for the presence of 12 V between TP7 and TP6. If 12 V is not present, the faulty FRU is the DC-DC board, which you must change (see Job Card D/R A287 - Collimator DC-DC Board on page 1379). 3. If 12 V is present then the DC-DC board is OK. Remove the jumper at TP1 on the DC-DC board and check the cable connection between (W500) control board and DC-DC board. If the cable is good, the faulty FRU is the collimator control board. 4. Reboot the system. If the error persists, change the Collimator Set (see Job Card D/R A280 - Collimator Set on page 1369). FRUs: Collimator Light Assembly DC-DC Board Collimator Set 2-40 JC DIAG A1402 COLL BLADE HOMING FAILURE Diagnostic for: 140/003 error code (CAN code is 0x5200) 140/004 error code (CAN code is 0x5200) 140/005 error code (CAN code is 0x5200) 140/006 error code (CAN code is 0x5200) 1. Check the cable connections (motor drive cable W501, optical sensor cable W504, motor cable W506 or W508). 2. Reboot the system. If the error persists, open the collimator cover, and check the blade position. If the blade is stuck at the inner or outer limit, turn the gear by hand to release the gear. Reboot the system and check the blade movement: a. If the blade moves in one way and does not change direction before the stop, the cause is linked to an optical sensor failure or collimator control board problem. b. If the blade does not move at all or the gear cannot be released by hand then the collimator box has failed. c. If the blade moves and changes directions for up to seven steps (normally it is three steps) and stops with motor power off, there is either an optical sensor problem or electrical noise on the collimator control board. In either of these cases above, change the Collimator Set (see Job Card D/R A280 - Collimator Set on page 1369). FRUs: Collimator Set Page no. 967 JC-DIAG-A-1000.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2-41 JC DIAG A1403 COLL FILTER HOMING FAILURE Diagnostic for: 140/007 error code (CAN code is 0x5200) 1. Check the cable connections (motor drive cable W501, optical sensor cable W505, motor cable W507 or W509). 2. Reboot the system. If the error persists, dismount the collimator box to be able to see the Filter Wheel. 3. If there is no interference within the spectral filter itself reboot the system and check the filter wheel movement: a. If the wheel turns in one way and does not change direction before the stop, the cause is linked to an optical sensor failure or collimator control board problem. b. If the wheel does not move at all or the gear cannot be released by hand then either the wheel has failed or there is failure in motor drive cable or control board. c. If the wheel turns and changes directions for up to seven steps (normally it is three steps) and stops with motor power off, there is either an optical sensor problem or electrical noise on the collimator control board. In either of these cases above, change the Collimator Set (see Job Card D/R A280 - Collimator Set on page 1369). 4. Turn the Filter Wheel manually - if there is mechanical interference the cause of the error is a mechanical assembly problem. Check whether the Filter Wheel interferes with the tube tilt plate screw, and if it does then reassemble the spectral filter and tilt plate. If there is interference within the spectral filter itself or the shutter is broken, change the Filter Wheel (see Job Card D/R A285 - Collimator Filter Wheel Assembly on page 1375). FRUs: Collimator Set Filter Wheel 2-42 JC DIAG A1404 COLL BLADE AXIS NOT READY Diagnostic for: 141/001 error code (CAN code is 0xA010) 141/002 error code (CAN code is 0xA010) 141/003 error code (CAN code is 0xA010) 141/004 error code (CAN code is 0xA010) 1. Check the cable connections (motor drive cable W501, optical sensor cable W504, motor cable W506 or W508). 2. Reboot the system. If the error persists and occurs at system boot, open the collimator cover, and check the blade position. If the blade is stuck at the inner or outer limit, turn the gear by hand to release the gear. Reboot the system and check the blade movement: a. If the blade moves in one way and does not change direction before the stop, the cause is linked to an optical sensor failure or collimator control board problem. b. If the blade does not move at all or the gear cannot be released by hand then the collimator box has failed. c. If the blade moves and changes directions for up to seven steps (normally it is three steps) and Chapter 9 Page no. 968 JC-DIAG-A-1000.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic stops with motor power off, there is either an optical sensor problem or electrical noise on the collimator control board. In either of these cases above, change the Collimator Set (see Job Card D/R A280 - Collimator Set on page 1369). 3. If the error persists during normal operation and not during system boot, check the error log to see whether there is another collimator blade error. • If there is another collimator error then refer to the diagnostics for that error to resolve the problem. • If there is no other collimator error then this error is due to the Gantry CPU sending a command to the collimator before the collimator could acknowledge previous command. In this case the faulty FRU is the Gantry CPU, which you must change (see Job Card D/R A190 - Gantry CPU Board on page 1131). FRUs: Collimator Set Gantry CPU 2-43 JC DIAG A1405 COLL FILTER NOT READY Diagnostic for: 141/005 error code (CAN code is 0x5200) 1. Check the cable connections (motor drive cable W501, optical sensor cable W505, motor cable W507 or W509). 2. Reboot the system. If the error persists, dismount the collimator box to be able to see the Filter Wheel. 3. If there is no interference within the spectral filter itself reboot the system and check the filter wheel movement: a. If the wheel turns in one way and does not change direction before the stop, the cause is linked to an optical sensor failure or collimator control board problem. b. If the wheel does not move at all or the gear cannot be released by hand then either the wheel has failed or there is failure in motor drive cable or control board. c. If the wheel turns and changes directions for up to seven steps (normally it is three steps) and stops with motor power off, there is either an optical sensor problem or electrical noise on the collimator control board. In either of these cases above, change the Collimator Set (see Job Card D/R A280 - Collimator Set on page 1369). 4. Turn the Filter Wheel manually - if there is mechanical interference the cause of the error is a mechanical assembly problem. Check whether the Filter Wheel interferes with the tube tilt plate screw, and if it does then reassemble the spectral filter and tilt plate. If there is interference within the spectral filter itself or the shutter is broken, change the Filter Wheel (see Job Card D/R A285 - Collimator Filter Wheel Assembly on page 1375). 5. If the error persists during normal operation and not during system boot, check the error log to see whether there is another collimator filter error. • If there is another collimator error then refer to the diagnostics for that error to resolve the problem. • If there is no other collimator error then this error is due to the Gantry CPU sending a command to the collimator before the collimator could acknowledge previous command. In this case the faulty Page no. 969 JC-DIAG-A-1000.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic FRU is the Gantry CPU, which you must change (see Job Card D/R A190 - Gantry CPU Board on page 1131). FRUs: Collimator Set Filter Wheel Gantry CPU 2-44 JC DIAG A1406 COLL BLADE OVERCURRENT Diagnostic for: 142/003 error code (CAN code is 0x5300) 142/004 error code (CAN code is 0x5300) 142/005 error code (CAN code is 0x5300) 142/006 error code (CAN code is 0x5300) 1. Check the cable connections, shielding, and grounding. 2. Reboot the system to check whether the error persists. If the error persists, open the collimator cover and check whether there is interference between the blade gear and cover (identified by scratches on the cover). If there has been interference between the blade gear and cover change the Collimator Set (see Job Card D/R A280 - Collimator Set on page 1369). If there has not been interference between the blade gear and cover, turn the corresponding blade gear manually in two directions. • If there is a mechanical hard point or the resistance in the two directions is noticeably different then check whether there is mechanical disconnection (screws, rails). If there is a mechanical disconnection try to recover the connection. If the mechanical disconnection cannot be recovered, change the Collimator Set (see Job Card D/R A280 - Collimator Set on page 1369). • If there is no a mechanical hard point or no noticeable resistance in the two directions, power on the system to check whether there is abnormal noise or vibration during blade movement. If there is abnormal noise or vibration, change the Collimator Set (see Job Card D/R A280 - Collimator Set on page 1369). FRUs: Collimator Set 2-45 JC DIAG A1407 COLL FILTER OVERCURRENT Diagnostic for: 142/007 error code (CAN code is 0x5300) 1. Check the cable connections, shielding, and grounding. 2. Reboot the system to check whether the error persists. If the error persists, dismount the collimator box to be able to see spectral filter. Turn the filter wheel manually, to check for mechanical interference: 3. If there is mechanical interference, there is a mechanical assembly problem. Check whether the Filter Wheel interferes with tube tilt plate screw. If the Filter Wheel interferes with tube tilt plate screw, reassemble spectral filter and tilt plate. • If the interference is within filter itself, change the Filter Wheel (see Job Card D/R A285 - Collimator Filter Wheel Assembly on page 1375). Chapter 9 Page no. 970 JC-DIAG-A-1000.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic • If no mechanical interference or no hard point, power on the system to check whether there is abnormal noise or vibration during filter movement: If there is still abnormal noise or vibration during filter movement, change the Filter Wheel (see Job Card D/R A285 - Collimator Filter Wheel Assembly on page 1375) If there is no longer abnormal noise or vibration during filter movement, change the change the Collimator Set (see Job Card D/R A280 - Collimator Set on page 1369). FRUs: Collimator Set Filter Wheel 2-46 JC DIAG A1500 AC MAINS FAILURE Diagnostic for: 152/000 error code (CAN code is 0x3100) External VAC mains error. • On the PL101 PDU Board check Channel 20. Here you can see the value of AC mains. (230 V ±10%). Check that it is within the range 180 V - 260 V. If not, the AC mains is out of tolerance limits. • If the board does not work, inspect the DS26 AC Power ON LED. Warning! 230 V AC power is present in this area! If the LED is lit, switch off the Gantry using the circuit breaker (MPCB: Bulkhead area B1, B2). • Inspect the fuses F5, F6. • Switch on the Gantry. • Check the AC mains voltage on W104. If it is good, check for this voltage on W127. • Check that the W124 cable is connected • If the voltage and fuses are good, change the PDU Board (see Job Card D/R A191 - PDU Board on page 1137). FRUs: F5, F6 fuses PDU Board 2-47 JC DIAG A1501 12V DC Generator Voltage Off Diagnostic for: 152/001 error code (CAN code is 0x3101) 12V DC Generator Voltage Off Probable cause: The 12 V DC signal from Generator Supply Command board to PDU board is not present, for one of the following reasons: • • • • • The Generator is powered off. There is a broken or bad TP10 connector on the Generator Supply Command board, or there is a broken or bad J2 connector on the PDU board. There is a faulty W125 cable between the Generator Supply Command board and PDU board. The PDU board is faulty. The Generator Supply Command board is faulty or the Mains Distribution Board is faulty Note: The occurrence of error 152/001 is normal during system boot-up time. However, if error 152/001 occurs after a system boot up, use the recommended actions below. Page no. 971 JC-DIAG-A-1000.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic Recommended Actions 1. Ensure that the Generator is powered on. 2. If the problem persists, use a multimeter to check the voltage between the TP10 connector and the top left bolt earth point on Generator Supply Command board. The expected voltage when the W125 cable connections are firmly in place is 9.2 V ± 0.5 Vdc. PVV Earth TP10 0VV • If the voltage between the TP10 connector and the earth point on the Generator Supply Command board is 9.2 V ± 0.5 V dc, change the PDU board according to Job Card D/R A191 - PDU Board on page 1137. • If the voltage between the TP10 connector and the earth point on the Generator Supply Command board is 12 V ± 1 V dc, there is an issue with the connection W125 cable between the Generator Supply Command board and the PDU board. In this case, do the following: Physically check for broken connections on the J2 connector on the PDU board and on the TP10 connector on Generator Supply Command board. If there are bad connections, ensure the cables are well connected. If there are broken connections, change the appropriate board according to Job Card D/R A408 - Generator Supply Command Board 200-PL2 on page 1583 or Job Card D/R A191 - PDU Board on page 1137. • If the voltage between the TP10 connector and the earth point on the Generator Supply Command board is less than 9.2 V ± 0.5 V dc, either the Generator Supply Command board is faulty or the Main Distribution board is faulty. In this case, check the voltage between test point PVV and 0VV on the Generator Supply Command board to determine which board to change. If the PVV to 0VV measured voltage is 12 V ± 1 V dc, change the Generator Supply Command board according to Job Card D/R A408 - Generator Supply Command Board 200-PL2 on page 1583. If the PVV to 0VV measured voltage is not 12 V ± 1 V dc, change the Mains Distribution board according to Job Card D/R A411 - Mains Distribution Board 200-PL1 on page 1601. Chapter 9 Page no. 972 JC-DIAG-A-1000.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2-48 JC DIAG A1502 ACDC MODULE POWER FAILURE Diagnostic for: 152/002 error code (CAN code is 0x3102) 48 V ACDC error • On the PL101 PDU Board, place a jumper in the upper position (pos 1-2) of J22. • Check that LED DS13 goes out (not lit). - If not, inspect the W107 cable connections, J3 connector on PDU Board and J138 connector on the PL102 board. - If the LED is still lit, change the PDU Board (see Job Card D/R A191 - PDU Board on page 1137). - If the error persists, check for 48 V (±5%) on channel 0. If no 48 V is measured, check the F2 fuse on Terminal block ST102, and the W110 and W117 cable connections. - If the error persists, change the AC/DC Module according to Job Card D/R A194 - AC/DC Module on page 1153. • Remove the jumper. FRUs: 20 A fuse PDU Board AC/DC Module Page no. 973 JC-DIAG-A-1000.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2-49 JC DIAG A1503 OVERCURRENT FAILURE Diagnostic for: 152/007 error code (CAN code is 0x3201) Current error • Check that the W109/111/113 shunt cable resistor R101 (0.01 Ohm) and its connections are good. If not, change it. There are two different circuits. 1. High Power. The motor drive current flows here only during lift or rotation motions. In the neutral position, the current is less than 10 mA on the W210 cable (for lift and rotation). If the current is more than this value, measure the current on W211 (for rotation). Change the appropriate board or the W211 cable. - Check the following connections: W210 Lift Board - J1 W211 Lift Board - J12 Rotation Board - J1 - Measure current on cable W210 while performing a rotation movement. It must be less than 20 A. - If it is more than 20 A, change the Rotation Board (Job Card D/R A221 - Rotation Board on page 1223). - Measure current on cable W210 while performing a lift movement. It must be less than 20 A. - If it is more than 20 A, change the Lift Board (see Job Card D/R A201 - Lift Board on page 1161). 2. Low Power. Measure current on cable W110. It must be less than 2 A. If it is more than 2 A, check the following cables, and connectors: - W116; J7 on PDU Board PL101 to J1 on Interface Board PL104. - W315; Arm distribution board J2 to PDU Board J6. - W310; Arm distribution board J4. - W313; Compression Board J9. - W307; Compression Board J1 to Arm distribution board J5. - W209; PDU Board J7 to Lift Board J2 - W212; Lift Board J13 to Rotation Board J2 FRUs: W109/111/113 Shunt and 48 V DC cable W211 48 V DC-HP BETWEEN NODES W212 48 V DC-HP BETWEEN NODES W310/W313 Interconnection Cable between Nodes W315 48 VDC LP2 Tube Tilt Board Compression Board Rotation Board Lift Board PDU Board Chapter 9 Page no. 974 JC-DIAG-A-1000.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2-50 JC DIAG A1504 LOW POWER 2 FUSE IS BAD Diagnostic for: 152/026 error code (CAN code is 0x5000) Fuse LP2 error • Inspect the F1 fuse on the PL101 PDU Board. If it is good, change the PDU Board (see Job Card D/ R A191 - PDU Board on page 1137). FRUs: F1 Fuse PDU Board 2-51 JC DIAG A1505 HIGH POWER FUSE IS BAD Diagnostic for: 152/027 error code (CAN code is 0x5001) Fuse HP error • Inspect the F1 (20 A fuse) on the MPCB Terminal Block ST102. If it is good, change the PDU Board (see Job Card D/R A191 - PDU Board on page 1137). FRUs: Fuse 20 A PDU Board 2-52 JC DIAG A1506 LOW POWER 1 FUSE IS BAD Diagnostic for: 152/028 error code (CAN code is 0x5002) Fuse LP1 error • Inspect the F3 fuse on the PL101 PDU Board. If it is good, change the PDU Board (see Job Card D/ R A191 - PDU Board on page 1137). FRUs: F3 Fuse PDU Board 2-53 JC DIAG A1507 MAIN CPU FUSE IS BAD Diagnostic for: 152/029 error code (CAN code is 0x5003) Fuse CPU error • Inspect the F4 fuse on the PDU Board. If it is good, change the PDU Board (see Job Card D/R A191 - PDU Board on page 1137). FRUs: F4 Fuse PDU Board Page no. 975 JC-DIAG-A-1000.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A1000 - Gantry Diagnostic 2-54 JC DIAG A1508 AC/DC Module Reports Power Failure Diagnostics for: 152/003 error code (CAN code is 0x3111) ACDC power error • Check whether the ’power fail’ LED is lit on the AC/DC Module. If yes, change the AC/DC Module according to Job Card D/R A194 - AC/DC Module on page 1153. • Move jumper J22 to its upper position (pins 1-2) to force the AC/DC module on. Check for the presence of 48 VDC on channel 0 of the PDU. If 48 VDC is not present, change the AC/DC Module according to Job Card D/R A194 - AC/DC Module on page 1153. Return jumper J22 to its normal position. • If the error persists, check for short circuits between any pins of cable W107. • If the cable is good, change the PDU Board (see Job Card D/R A191 - PDU Board on page 1137). FRUs: AC/DC Module PDU Board 2-55 JC DIAG A1509 AC/DC Module Reports Fan Failure Diagnostics for: 152/004 error code (CAN code is 0x3112) ACDC fan error • Check whether the "fan fail" LED is lit on the AC/DC Module. If yes, change the AC/DC Module according to Job Card D/R A194 - AC/DC Module on page 1153. • If not, check for short circuits between any pins of cable W107. • If the cable is good, change the PDU Board (see Job Card D/R A191 - PDU Board on page 1137). FRUs: AC/DC Module PDU Board 2-56 JC DIAG A1510 AC/DC Module Reports Over Temperature Diagnostics for: 152/005 error code (CAN code is 0x3113) ACDC temperature error • Check whether the ’over temperature’ LED is lit on the AC/DC Module. If yes, - First check that no obstruction in the cooling air path is preventing the AC/DC Module fans from cooling the module. - If the air flow path is good, change the AC/DC Module according to Job Card D/R A194 - AC/DC Module on page 1153. • If the LED is not lit: - Check for short circuits between any pins of cable W107 - If the cable is good, change the PDU Board (see Job Card D/R A191 - PDU Board on page 1137). FRUs: AC/DC Module W107 cable PDU Board Chapter 9 Page no. 976 JC-DIAG-A-1000.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A001 - AWS Sun-VTS Diagnostics Job Card DIAG A001 - AWS Sun-VTS Diagnostics 1 Chapter 9 APPLICABILITY This Job Card is only applicable to V1/V2/V3 Control Stations. 2 INTRODUCTION This Job Card describes Sun-VTS diagnostic procedures for the AWS (Acquisition Workstation) The AWS consists of a Solaris computer, some components connected externally (e.g., modem onV1/ V2 Control Stations) and a set of subsystems. AWS diagnostics include diagnostics for the workstation hardware, software processes in the workstation, and connection to the subsystems. The diagnostics tests the AWS hardware components, locates any non-functional subsystem, and then locates a non-functional FRU (Field Replaceable Unit). 2-1 Access to the Tests You can launch all of the tests from a command window as sdc or root user (local use only). To launch a command line window, click the title bar of the Browser window and move the Browser to expose the background. Right click the background of the Browser screen, and from the Root menu that appears, select Service Tools then select Command window. Note: Since the Browser is launched automatically by logging in as the sdc UNIX user at the first console login: prompt, any command line window that is launched from a Browser session automatically runs as the sdc user. Most service-based procedures use the sdc user. In cases where you are required to log in as a different UNIX user, the instructions provide you with the appropriate steps to log in as that UNIX user. 2-2 SUN Document References If you need additional information to diagnose the AWS, you can find appropriate SUN documentation at the following URLs: • For V1/V2 Control Stations: SB150: https://www.sun.com/products-n-solutions/hardware/docs/Workstation_Products/Workstations/ Sun_Blade_Workstations/Sun_Blade_150/index.html • For V3 Control Stations: U20: https://www.sun.com/products-n-solutions/hardware/docs/Workstation_Products/Workstations/ ultra_20/index.html Page no. 977 JC-DIAG-A-001.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A001 - AWS Sun-VTS Diagnostics 3 PROCESSOR TESTS 3-1 Short Test • Type of test: SUN VTS For both V1/V2 and V3 Control Stations, from the command window, enter: /opt/SUNWvts/bin/fputest –v –n 3-2 • Long Test Type of test: SUN VTS For both V1/V2 and V3 Control Stations, from the command window, enter: /opt/SUNWvts/bin/fputest –v –f 4 HARD DRIVE TESTS V1/V2 Control Stations have two hard disks with device names c0t0d0 and c0t1d0. V3 Control Stations have one large hard disk with device name c1d0. 4-1 • Short Test Type of test: SUN VTS For V1/V2 Control Stations to perform a short test on hard disk with device name c0t0d0, from a command window, enter: /opt/SUNWvts/bin/disktest –v -n -o dev=c0t0d0 For V1/V2 Control Stations to perform a short test on hard disk with device name c0t1d0, from a command window, enter: /opt/SUNWvts/bin/disktest –v -n -o dev=c0t1d0 For V3 Control Stations to perform a short test on hard disk with device name c1d0, from a command window, enter: /opt/SUNWvts/bin/disktest –v -n -o dev=c1d0 4-2 • Long Test Type of test: SUN VTS For V1/V2 Control Stations to perform a long test on hard disk with device name c0t0d0, from a command window, enter: /opt/SUNWvts/bin/disktest –v -f -o dev=c0t0d0 For V1/V2 Control Stations to perform a long test on hard disk with device name c0t1d0, from a command window, enter: /opt/SUNWvts/bin/disktest –v -f -o dev=c0t1d0 For V3 Control Stations to perform a long test on hard disk with device name c1d0, from a command window, enter: /opt/SUNWvts/bin/disktest –v -f -o dev=c1d0 Chapter 9 Page no. 978 JC-DIAG-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A001 - AWS Sun-VTS Diagnostics 5 • PHYSICAL MEMORY TESTS Type of test: SUN VTS On V1/V2 Control Stations, from a command window, enter: /opt/SUNWvts/bin/pmem –v -f -o size=100 On V3 Control Stations, from a command window, enter: /opt/SUNWvts/bin/pmemtest –v -f -o size=100 6 VIRTUAL MEMORY TESTS 6-1 Short Test • Type of test: SUN VTS On V1/V2 Control Stations, from a command window, enter: /opt/SUNWvts/bin/vmem –v -f -o amount=100 On V3 Control Stations, from a command window, enter: /opt/SUNWvts/bin/vmemtest –v -f -o amount=100 6-2 • Long Test Type of test: SUN VTS On V1/V2 Control Stations, from a command window, enter: /opt/SUNWvts/bin/vmem –v –f -o reserve=100 On V3 Control Stations, from a command window, enter: /opt/SUNWvts/bin/vmemtest –v –f -o reserve=100 7 • VIDEO BOARD TESTS Type of test: SUN VTS Note: Video board tests are only applicable to V1/V2 Control Stations. On V1/V2 Control Stations, from a command window, enter: /opt/SUNWvts/bin/m64test 8 • FLOPPY DRIVE TESTS Type of test: SUN VTS Note: Floppy drive tests are only applicable to V1/V2 Control Stations. 1. From a command window, log in as root as follows: a. At the ADS prompt enter: su Page no. 979 JC-DIAG-A-001.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A001 - AWS Sun-VTS Diagnostics b. When requested to specify the root password, enter: operator 2. Insert a formatted floppy disk 3. From the command window, enter: /opt/SUNWvts/bin/disktest –v -f -o dev=diskette 9 INTERNAL CD-ROM OR CD-WRITER TESTS 9-1 Short Test • Type of test: SUN VTS On V1/V2 Control Stations, from a command window, enter: /opt/SUNWvts/bin/cdtest –v -n -o dev=c0t2d0 On V3 Control Stations, from a command window, enter: /opt/SUNWvts/bin/cddvdtest –v -n -o dev=c0t0d0 9-2 Long Test • Type of test: SUN VTS 1. Insert a formatted cd-rom disk (not blank). 2. Perform the long test as follows. On V1/V2 Control Stations, from a command window, enter: /opt/SUNWvts/bin/cdtest –v –f -o dev=c0t2d0 On V3 Control Stations, from a command window, enter: /opt/SUNWvts/bin/cddvdtest –v –f -o dev=c0t0d0 9-3 • 1. 2. 3. CD-ROM Diagnostics Type of test: Service Desktop Launch the Service Desktop (see Launching the Service Desktop on page 120). From the Service Desktop, select Diagnostics > SUBSYSTEMS > AWS. Select the either the Internal CD Reader or External CD Reader radio button, then click START. Note: The External CD Reader tests do not work on V3 Control Stations, since there is no external CDROM. 4. Follow the instructions presented by the Service Desktop to complete the CD-ROM diagnostics. 10 TESTS FOR EXTERNAL CD WRITER IF PRESENT Note: External CD Writer tests are only applicable to V1 Control Stations that have an external CD Writer. 10-1 Short Test • Type of test: SUN VTS On V1/V2 Control Stations, from a command window, enter: /opt/SUNWvts/bin/cdtest –v -n -o dev=c1t2d0 Chapter 9 Page no. 980 JC-DIAG-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A001 - AWS Sun-VTS Diagnostics 11 ADS-UPS LINE TESTS 11-1 Internal Tests • Type of test: SUN VTS Note: Internal ADS-UPS line tests are only applicable to V1/V2 Control Stations. 11-1-1 Internal Tests on V1/V2 Control Stations 1. Power up the system and wait for the console login: prompt on the AWS monitor. 2. Within 20 seconds of seeing the login prompt, stop the UPS daemon by doing the following: a. At the console login: prompt, login as root by entering: root b. When requested to specify the root password, enter: operator c. Stop the UPS daemon, by entering: ups stop 3. Once the UPS has stopped run the internal test from the command line, by entering: /opt/SUNWvts/bin/sptest –v -f -o dev=se0,L=I,T=b 4. One the internal tests are complete restart the UPS from the command line, by entering: ups start 11-2 Full Test without Cable • Type of test: SUN VTS 11-2-1 Full Tests without Cable on V1/V2 Control Stations 1. Power up the system and wait for the console login: prompt on the AWS monitor. 2. Within 20 seconds of seeing the login prompt, stop the UPS daemon by doing the following: a. At the console login: prompt, login as root by entering: root b. When requested to specify the root password, enter: operator c. Stop the UPS daemon, by entering: ups stop 3. Once the UPS has stopped, remove the UPS cable from the serial port b of the AWS Computer. 4. Plug a Standard RS-232 Loopback Adapter into serial port b of the AWS Computer. 5. Run the test from the command line, by entering: /opt/SUNWvts/bin/sptest –v -f -o dev=se0,L=P,T=b 6. Once the test is complete reconnect the UPS cable to the serial port b of the AWS Computer. 7. Restart the UPS from the command line, by entering: ups start Page no. 981 JC-DIAG-A-001.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A001 - AWS Sun-VTS Diagnostics 11-2-2 Full Tests without Cable on V3 Control Stations 1. Power up the system and wait for the console login: prompt on the AWS monitor. 2. Login as root as follows: a. At the console login: prompt, login as root by entering: root b. When requested to specify the root password by entering: operator 3. A list of start up messages appear, while the ADS Computer boots up. Wait for the following message to appear: ********************************************* * UPS Communication not established * * System will shutdown * ********************************************* 4. Stop the UPS daemon, by entering: /etc/rc2.d/S99PBEAgent stop 5. Once the UPS has stopped, remove the UPS cable from Slot #2 of PCI1 of the AWS Computer. 6. Plug a Standard RS-232 Loopback Adapter into Slot #2 of PCI1 on the AWS Computer. 7. Run the test from the command line, by entering: tip /dev/term/3 The system answers Connected. 8. Type some alphanumeric characters on the keyboard. If the board is good, they are echoed immediately on the screen 9. To exit the test, type the command: ~. Note: It can be necessary to repeat the sequence several times. 10. Once the test is complete reconnect the UPS cable to Slot #2 of PCI1of the AWS Computer. 11. Restart the UPS from the command line, by entering: ups start 11-3 Full Test with Cable • Type of test: SUN VTS 11-3-1 Full Tests with Cable on V1/V2 Control Stations 1. Power up the system and wait for the console login: prompt on the AWS monitor. 2. Within 20 seconds of seeing the login prompt, stop the UPS daemon by doing the following: a. At the console login: prompt, login as root by entering: root b. When requested to specify the root password, enter: operator c. Stop the UPS daemon, by entering: ups stop 3. Once the UPS has stopped, remove the UPS cable from the serial port of the UPS. 4. Plug a loopback connector "Connector-Loopback UPS" into the end of the disconnected UPS cable. 5. Run the test from the command line, by entering: /opt/SUNWvts/bin/sptest –v -f -o dev=se0,L=P,T=b Chapter 9 Page no. 982 JC-DIAG-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A001 - AWS Sun-VTS Diagnostics 6. Once the test is complete reconnect the UPS cable to the serial port of the UPS. 7. Restart the UPS from the command line, by entering: ups start 11-3-2 Full Tests without Cable on V3 Control Stations 1. Power up the system and wait for the console login: prompt on the AWS monitor. 2. Login as root as follows: a. At the console login: prompt, login as root by entering: root b. When requested to specify the root password by entering: operator 3. A list of start up messages appear, while the ADS Computer boots up. Wait for the following message to appear: ********************************************* * UPS Communication not established * * System will shutdown * ********************************************* 4. Stop the UPS daemon, by entering: /etc/rc2.d/S99PBEAgent stop 5. Once the UPS has stopped, remove the UPS cable from Slot #2 of PCI1 of the AWS Computer. 6. Plug a Standard RS-232 Loopback Adapter into Slot #2 of PCI1 on the AWS Computer. 7. Run the test from the command line, by entering: tip /dev/term/3 The system answers Connected. 8. Type some alphanumeric characters on the keyboard. If the board is good, they are echoed immediately on the screen 9. To exit the test, type the command: ~. Note: It can be necessary to repeat the sequence several times. 10. Once the test is complete reconnect the UPS cable to the serial port of the UPS. 11. Restart the UPS from the command line, by entering: ups start 12 ADS-SENOGRAPHE LINE TESTS 12-1 Full Test without Cable • Type of test: UNIX command 1. Power up the system and wait for the console login: prompt on the AWS monitor. 2. Login as root as follows: a. At the console login: prompt, login as root by entering: root b. When requested to specify the root password by entering: operator 3. Remove the Senographe cable from the port 1 of Digi Board (additional serial board.) Page no. 983 JC-DIAG-A-001.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A001 - AWS Sun-VTS Diagnostics 4. For V1/V2 Control Stations, plug a Standard RS-232 Loopback Adapter in port 1 of Digi Board on the AWS Computer. For V3 Control Stations, plug a Standard RS-232 Loopback Adapter into Slot #1 of PCI0 on the AWS Computer. 5. Run the full test as follows: For V1/V2 Control Stations from the command line, enter: tip /dev/dty/a001s For V3 Control Stations from the command line, enter: tip /dev/term/0 The system answers Connected. 6. Type some alphanumeric characters on the keyboard. If the board is good, they are echoed immediately on the screen 7. To exit the test, type the command: ~. Note: It can be necessary to repeat the sequence several times. 8. Reconnect the cable when the test is complete. 12-2 Full Test with Cable • Type of test: UNIX command 1. Power up the system and wait for the console login: prompt on the AWS monitor. 2. Login as root as follows: a. At the console login: prompt, login as root by entering: root b. When requested to specify the root password by entering: operator 3. Remove the Senographe cable from the Senographe serial port. 4. Plug a Standard RS-232 Loopback Adapter in the end of the cable. 5. Run the full test as follows: For V1/V2 Control Stations from the command line, enter: tip /dev/dty/a001s For V3 Control Stations from the command line, enter: tip /dev/term/0 The system answers Connected. 6. Type some alphanumeric characters on the keyboard. If the cable is good, they are echoed immediately on the screen 7. To exit the test, type the command: ~. Note: It can be necessary to repeat the sequence several times. 8. Reconnect the cable when the test is complete. Chapter 9 Page no. 984 JC-DIAG-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A001 - AWS Sun-VTS Diagnostics 13 AWS-IDC LINE TEST (EXTERNAL) Type of test: SUN VTS For V1/V2 Control Stations from a command window, enter: /opt/SUNWvts/bin/nettest –v -f -o dev=hme0,target=IDC • For V3 Control Stations from a command window, enter: /opt/SUNWvts/bin/nettest –v -f -o dev=nge1,target=IDC 14 MOTHER BOARD SERIAL PORTS TESTS 14-1 Internal Test • Type of test: SUN VTS Note: Motherboard serial port tests are only applicable to V1/V2 Control Stations because the V3 Control Stations do not have onboard serial ports. On V1/V2 Control Stations, from a command window, enter: /opt/SUNWvts/bin/sptest –v –n -o L=I,T=a_b Page no. 985 JC-DIAG-A-001.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A001 - AWS Sun-VTS Diagnostics This page is blank. Chapter 9 Page no. 986 JC-DIAG-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A002 - AWS Ethernet Port Diagnostics Job Card DIAG A002 - AWS Ethernet Port Diagnostics 1 Chapter 9 INTRODUCTION This Job Card describes diagnostic procedures for the AWS (Acquisition Workstation) Ethernet ports. The AWS consists of a Solaris computer, some components connected externally (e.g., modem for V1/ V2 Control Stations) and a set of subsystems. AWS diagnostics include diagnostics for the workstation hardware, software processes in the workstation, and connection to the subsystems. The diagnostics tests the AWS hardware components, locates any non-functional subsystem, and then locates a non-functional FRU (Field Replaceable Unit). 2 COMMON PROCEDURES (FOR V1/V2 CONTROL STATIONS) Many of the tests on the V1/V2 Control Station require you to run them from the ok prompt. This section describes how to obtain the ok prompt and how to return to the AWS application from the ok prompt. Note: Tests run from the ok prompt is only applicable to V1/V2 Control Stations. 2-1 Go to ok Prompt 1. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 2. Log in as root as follows: a. At the ADS prompt enter: su b. When requested to specify the root password, enter: operator 3. Execute the halt command by entering: halt An ok prompt appears. 2-2 Relaunch the AWS Application To re-launch the AWS application from the ok prompt proceed as follows: 1. At the ok prompt, enter: setenv auto-boot? true 2. At the ok prompt, enter: boot A console login: prompt appears. 3. Login as the sdc user as follows: a. At the console login: prompt enter: sdc b. At the Password: prompt, press the key. The AWS login screen appears after a short delay. Page no. 987 JC-DIAG-A-002.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A002 - AWS Ethernet Port Diagnostics 3 AWS-IDC LINE TESTS 3-1 Internal Test (for V1/V2 Control Stations) • Type of test: Open boot command Note: The internal test is only applicable to V1/V2 Control Stations. 1. Go to the ok prompt (see Go to ok Prompt on page 987). 2. At the ok prompt, enter: test net 3. Relaunch the AWS application (see Relaunch the AWS Application on page 987). • Result interpretation: After the command has been entered, the following information appears: Internal loopback test – Result 1 Transceiver check – Result 2 where Result 1 and Result 2 are the results of each sub-test. - If Result 1 is not Succeeded, the AWS motherboard is faulty. You must replace the ADS Computer (see Job Card D/R A311 - AWS Unit on page 1401). - If Result 1 is OK & Result 2 is not ok, the AWS transceiver is faulty. You must replace the ADS Computer (see Job Card D/R A311 - AWS Unit on page 1401). - If Result 1 & Result 2 are ok, the AWS motherboard is good, and either the cable is faulty or the IDC is faulty. In this case, replace the Ethernet cable between the ADS Computer and IDC with a cable that is known to work. Then attempt to ping the IDC, by entering ping idc If the IDC responds to the ping command, the cable was faulty. If the IDC still does not respond to the ping command then the IDC is faulty and needs replacing. 3-2 External Test (for All Control Stations) • Type of test: SUN VTS 1. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). 2. Run the external test as follows: For V1/V2 Control Stations, at the prompt in the command window, enter: /opt/SUNWvts/bin/nettest –v -f -o dev=ce0,target=IDC For V3 Control Stations, at the prompt in the command window, enter: /opt/SUNWvts/bin/nettest –v -f -o dev=nge1,target=IDC For V4 Control Stations, at the prompt in the command window, enter: /opt/SUNWvts/bin/nettest –v -f -o dev=e1000g0,target=IDC Chapter 9 Page no. 988 JC-DIAG-A-002.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A003 - AWS File System and SCSI Board Diagnostics Job Card DIAG A003 - AWS File System and SCSI Board Diagnostics 1 Chapter 9 INTRODUCTION This Job Card describes diagnostic procedures for the AWS (Acquisition Workstation) File system and SCSI board. The AWS consists of a Solaris computer, some components connected externally (e.g., modem) and a set of subsystems. AWS diagnostics include diagnostics for the workstation hardware, software processes in the workstation, and connection to the subsystems. The diagnostics tests the AWS hardware components, locates any non-functional subsystem, and then locates a non-functional FRU (Field Replaceable Unit). 1-1 Access to the Tests There are two ways to launch an AWS diagnostic: • From a command window as sdc or root user (local use only) • From the ok prompt (local use only) 2 COMMON PROCEDURES 2-1 Open a Command Window Right click the screen background; select Service tools and then select Command window from root menu. 2-2 Go to ok Prompt Note: Going to the ok prompt is only applicable to V1/V2 Control Stations. 1. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 2. Log in as root as follows: a. At the ADS prompt enter: su b. When requested to specify the root password, enter: operator 3. Execute the halt command by entering: halt An ok prompt appears. Page no. 989 JC-DIAG-A-003.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A003 - AWS File System and SCSI Board Diagnostics 2-3 Relaunch the AWS Application Note: Relaunching the AWS application is only applicable to V1/V2 Control Stations. To re-launch the AWS application from the ok prompt proceed as follows: 1. At the ok prompt, enter: setenv auto-boot? true 2. At the ok prompt, enter: boot A Login: prompt appears. 3. Login as the sdc user as follows: a. At the Login: prompt enter: sdc b. At the Password: prompt, press the key. The AWS login screen appears after a short delay. 2-4 Change UNIX User To change UNIX user proceed as follows: 1. From a command line window, enter: su - where is a valid UNIX user such as root or sdc. 2. If a Password: prompt appears, enter the appropriate password for the username you initially specified. 3 FILE SYSTEM FSCK TEST • • Type: UNIX command Description: This test checks the file system. It must be launched when the file system is suspected to be corrupt. For example, the AWS has been powered off manually, files can not be found, boot does not succeed, or some basic system functions are not available. These problems are detected by the operating system during the boot and you are prompted to run fsck. Procedure: 1. Shutdown and power up the AWS. 2. From the Login: prompt that appears, log in as root as follows: a. At the Login: prompt enter: root b. When requested to specify the root password, enter: operator 3. At the command line, enter: fsck -y 4. At the command line, enter: echo $status 5. If the result is not equal to 0 or 40: a. If not done since the last configuration modification, backup the system to a floppy diskette or a CD-R (see Job Card ELE A052 - Back-up/Restore Procedure on page 771). Chapter 9 Page no. 990 JC-DIAG-A-003.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A003 - AWS File System and SCSI Board Diagnostics b. Re-install the AWS system from scratch (see the AWS Software Installation booklet that comes with the AWS Software CD-ROM). 4 SCSI BOARD TESTS Note: SCSI board tests are only applicable to V1/V2 Control Stations. • Type: Open boot command 1. Go to the ok prompt (see Go to ok Prompt on page 989). 2. At the command line, enter: probe-scsi-all 3. Relaunch the AWS application (see Relaunch the AWS Application on page 990). • Result interpretation: If no SCSI identifier is found, the SCSI board is faulty. On a system with a cd-writer, two identifiers are detected; the SCSI controller itself and the CD-writer. An example of a result showing two SCSI identifiers is given below: /pci@1f,0/pci@1/pci@1/SUNW,isptwo@4 Page no. 991 JC-DIAG-A-003.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A003 - AWS File System and SCSI Board Diagnostics This page is blank. Chapter 9 Page no. 992 JC-DIAG-A-003.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A005 - Error Log Retrieval Job Card DIAG A005 - Error Log Retrieval 1 Chapter 9 INTRODUCTION When investigating difficult problems that require engineering support, it is sometimes necessary to capture error log information from the AWS/ADS for transmission to engineering personnel. Typically, you use the procedures in this Job Card when the Senographe system cannot connect to the OLC, and you have use an alternative approach to transfer the log files to your engineering contact. The procedures below assume that log files are copied directly to either a writable CD-R disk or a floppy disk, for transmission to your engineering contact. The writable CD-R disk is the preferred media type as its storage capacity is much higher than a floppy disk. However, the use of a writable CD-R disk is only possible from ADS versions 31.27 and above. Note: On V3/V4 Control Stations, there is no floppy disk drive, and only a writable CD-ROM exists.. 2 TOOLS N/A 3 SUPPLIES A writable CD-R disk or formatted floppy disks. 4 PRE-REQUISITES The AWS must be functional. 5 PROCEDURES 5-1 Error Log Files The following error log files can be of interest. All are located in the directory /export/home/sdc/senovision/logfiles: • error.log: Records information for all detected errors, including the type of error (halt, warning, advisory, debug only), date/time of occurrence, and the software module in which the error occurred. If the file grows too large, it is renamed as error.log.back and a new error.log is generated. • ExamEvents.log: Records a summary of image parameters. • ImageMeasures.stat: Records details of image IQ parameters. • trace.SenoServer.log: Records events seen by the ADS, describing the ADS to Generator communications. Because this file collects all events from ADS modules, its size grows rapidly • trace.positioner.log: Records Positioner CPU events. • PoseidonEvents.log: Records all Operator inputs on the Gantry, for system usage statistics. Note: The error log file names can vary, because the system concatenates date and time to the file name. When the log file directory is full, the current log files are compressed and transferred into /export/home/ sdc/senovision/logfiles/oldfiles. The compressed files are identified by use of the file name extension .Z (e.g., logfile.log becomes logfile.log.Z). Page no. 993 JC-DIAG-A-005.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A005 - Error Log Retrieval 5-2 Transfer to Laptop by FTP It is also possible to use FTP to copy log files to your laptop for later transmission. To do this, you must configure connect your laptop to the switch in the Control Station (see section 5-2-1), and configure your laptop network interface card (NIC) to be on the same network as the Senographe system (see section 5-2-2). 5-2-1 Connect Laptop to Control Station Switch 5-2-1-1 V1/V2 Control Stations and Pre-Penduick V3 Control Stations 1. Remove the X-ray Console. 2. Remove the Control Station top cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 3. Remove the Control Station omega cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 4. Use a straight Ethernet cable to connect the network interface card (NIC) of your laptop to the Ethernet Switch in the Control Station. The location of the switch varies depending on whether you have a V1/V2 Control Station or V3 Control Station, as shown below. Ethernet Switch V1/V2 Control Stations Chapter 9 V3 Control Stations Page no. 994 JC-DIAG-A-005.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A005 - Error Log Retrieval 5-2-1-2 Penduick and above V3 Control Stations and V4 Control Stations 1. Carefully remove the caps from each corner of the Omega window. 1 2. Remove each of the four screws and plastic washers from each corner of the Omega window, and remove the Omega window to reveal the RJ-45 Service connector (1). 3. Use a straight Ethernet cable to connect the network interface card (NIC) of your laptop to the RJ-45 Service connector (1) in the Control Station. 1 Page no. 995 JC-DIAG-A-005.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A005 - Error Log Retrieval 5-2-2 Configure Laptop NIC In order for your laptop to be able to establish an FTP connection with the AWS (and IDC), its network interface card (NIC) must be configured with an IP Address on the same network as the Senographe system. To do this, do the following on your laptop: 1. Open the Windows Network Connections window, using one of the following methods: • from the Windows Desktop, right mouse click on My Network Places and select Properties • click START > Settings > Control Panel, then double click on Network Connections 2. From the Network Connections window, right mouse click on the NIC that you plan to connect to the Senographe system, and select Properties. 3. From the Local Area Connection Properties window that appears, select the Internet Protocol (TCP/IP) item, and click Properties. Chapter 9 Page no. 996 JC-DIAG-A-005.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A005 - Error Log Retrieval 4. From the Internet Protocol (TCP/IP) Properties window that appears, select the Use the following IP Address radio button, then specify an IP Address of 192.168.1.29 and a Netmask of 255.255.255.0. 5. 6. 7. 8. In the Internet Protocol (TCP/IP) Properties window, click OK to accept the settings. When returned to the Local Area Connection Properties window, click Close. Open a Command Window (Start > Run, then enter cmd and click OK). From the Command Window that appears, verify that the IP address you configured is correct, by entering: ipconfig The Command Widow updates similar to the following, and should display the correct IP Address. Page no. 997 JC-DIAG-A-005.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A005 - Error Log Retrieval 9. Ensure that the ADS is reachable by entering the following ping command: ping 192.168.1.10 The Command Window should update similar to the following. 10. Ensure that the IDC is reachable by entering the following ping command: ping 192.168.1.20 The Command Window should update similar to the following. 5-2-3 Getting ADS Log Files The following steps describe getting the ADS log files on to your laptop via FTP, using the Command Window. Alternatively, you can use a graphical FTP client such as HummingBird FTP Client, CoreFTP or FileZilla to get the ADS log files. The principles of getting the ADS log files are the same as those below (i.e. IP address, username/password, file locations are all the same, and transfer mode is Binary (not ASCII)). 1. On your laptop, open a Command Window (Start > Run, then enter cmd and click OK). The path of the Command Window will be D:\Documents and Settings\. 2. Create a new directory within D:\Documents and Settings\ with the date format YYMMDD, by entering: mkdir YYMMDD where YYMMDD represents the current date (e.g. 081117 for 17th November 2008). 3. Change into the YYMMDD directory, by entering: cd YYMMDD Chapter 9 Page no. 998 JC-DIAG-A-005.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A005 - Error Log Retrieval where YYMMDD represents the current date (e.g. 081117 for 17th November 2008). 4. Create an ADS directory within D:\Documents and Settings\\YYDDMM, by entering: mkdir ADS 5. Change to the ADS directory, by entering: cd ADS 6. Create an oldfiles directory within D:\Documents and Settings\\YYDDMM\ADS, by entering: mkdir oldfiles 7. Create a messages directory within D:\Documents and Settings\\YYDDMM\ADS, by entering: mkdir messages 8. Establish an FTP connection with ADS, by entering: ftp 192.168.1.10 9. Login to ADS as follows: a. When prompted for the user, enter insite. b. When prompted for the password, enter 2getin. 10. Specify binary transfer mode for the FTP connection, by entering: bin 11. Change to the ADS /export/home/sdc/senovision/logfiles directory, by entering: cd /export/home/sdc/senovision/logfiles 12. List the log files in the /export/home/sdc/senovision/logfiles directory, by entering: ls The filenames of the different log files located in the /export/home/sdc/senovision/logfiles directory appear. Check to see if the error.log.back file exists. 13. Change to prompt mode (so you do not need to confirm every file that you get), by entering: prompt 14. Transfer all of the log files to your laptop, by entering: mget * 15. Change to the D:\Documents and Settings\\YYDDMM\ADS\oldfiles directory locally on your laptop, by entering: lcd oldfiles 16. Change to the ADS /export/home/sdc/senovision/logfiles/oldFiles directory, by entering: cd oldFiles 17. Transfer all of the compressed *.Z files to your laptop, by entering: mget *.Z 18. Change back up one level to the D:\Documents and Settings\\YYDDMM\ADS\ directory locally on your laptop, by entering: lcd .. 19. Change to the D:\Documents and Settings\\YYDDMM\ADS\messages directory locally on your laptop, by entering: lcd messages 20. Change to the ADS /var/adm directory, by entering: cd /var/adm 21. Transfer the messages file to your laptop, by entering: Page no. 999 JC-DIAG-A-005.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A005 - Error Log Retrieval get messages 22. Exit the FTP connection to ADS by entering: bye The FTP connection with the ADS closes, and you are returned to the DOS prompt prompt in the Command Window. 23. Close the command Window, by entering: exit 5-2-4 Getting IDC Log Files The following steps describe getting the IDC log files on to your laptop via FTP, using the Command Window. Alternatively, you can use a graphical FTP client such as HummingBird FTP Client, CoreFTP or FileZilla to get the IDC log files. The principles of getting the IDC log files are the same to those below (i.e. IP address, username and password, file locations are all the same). 1. On your laptop, open a Command Window (Start > Run, then enter cmd and click OK). The path of the Command Window will be D:\Documents and Settings\. 2. Create a new directory within D:\Documents and Settings\ with the date format YYMMDD, by entering: mkdir YYMMDD where YYMMDD represents the current date (e.g. 081117 for 17th November 2008). 3. Change into the YYMMDD directory, by entering: cd YYMMDD where YYMMDD represents the current date (e.g. 081117 for 17th November 2008). 4. Create an IDC directory within D:\Documents and Settings\\YYDDMM, by entering: mkdir IDC 5. Change to the IDC directory, by entering: cd IDC 6. Establish an FTP connection with IDC, by entering: ftp 192.168.1.20 7. When prompted for a username and password to access the IDC via FTP, press the key. 8. Specify binary transfer mode for the FTP connection, by entering: bin 9. Change to the /idc directory on the IDC, by entering: cd /idc 10. Transfer the errorlog.txt file to your laptop, by entering: get errorlog.txt 11. Transfer the sensor.txt file to your laptop, by entering: get sensor.txt 12. Disconnect the current FTP session with the IDC by entering: bye The FTP connection with the IDC closes, and you are returned to the DOS prompt prompt in the Command Window. 13. Close the command Window, by entering: exit 5-2-5 Sending ADS and IDC Log Files Use your favorite compression package (such as Winzip, 7zip, or WinRar) to create ZIP files of the Chapter 9 Page no. 1000 JC-DIAG-A-005.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A005 - Error Log Retrieval D:\Documents and Settings\\YYDDMM\ADS\ and D:\Documents and Settings\\YYDDMM\IDC\ and send them to your OLC by your preferred method. 5-3 Copying the Log Files to a CD-R Disk This section describes the steps you must undertake in order to copy the all of the Senographe system log files to a writable CD-R disk. This is the preferred approach for copying the log files to physical media because the capacity of the writable CD-R disk is far larger than a floppy disk. The resulting number of steps to copy the files is far less. Note: The use of a writable CD-R disk is only possible from ADS versions 31.27 and above. Note: Since the V3/V4 Control Station does not contain a floppy disk drive, you must use the steps in this section if you are copying log files on V3/V4 Control Stations. Use the following steps to copy the Senographe system log files to a writable CD-R disk. 1. Insert a writable CD-R disk into the Senographe system writable CD-ROM drive. 2. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 3. Run the BurnCdr.sh script to copy the contents of the /export/home/sdc/senovision/logfiles directory, the contents of the /export/home/sdc/logfiles directory, and the /var/adm/messages file to the CD-R disk, with a CD volume name of your choice, by entering: BurnCdr.sh -i -k -v /export/home/sdc/senovision/logfiles/ /var/adm/messages /export/home/sdc/logfiles/ where is your preferred name for the CD volume name. Note: In the command above, there is a space between /export/home/sdc/senovision/logfiles and /var/ adm/messages, and a space between /var/adm/messages and /export/home/sdc/logfiles (i.e. there is a space between each of the directories or files you want to copy). 4. Once the BurnCdr.sh script completes copying the log files to the CD-R disk, you are prompted to eject the CD-ROM. Accept the prompt, remove the CD-R disk from the CD-ROM drive and close the CD-ROM drive. 5. Exit the command window by entering: exit The command window closes. 6. Send the CD-R disk containing the saved log files to your engineering contact. Page no. 1001 JC-DIAG-A-005.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A005 - Error Log Retrieval 5-4 Copying the Log Files to a Floppy Disk This section describes the steps you must undertake in order to copy the all of the Senographe system log files to a floppy disk. Since the floppy disk has a small capacity, many steps can be required to compress the log files and to copy them on multiple disks. Therefore, the preferred approach is to copy the log files to a writable CR-ROM. Note: A floppy disk drive only exists on V1/V2 Control Stations. For V3/V4 Control Stations, you must copy the log files using CD-R media. Note: Since the V3/V4 Control Station only has a CD-RW drive, you can only use the steps in this section on a V1/V2 Control Station. 5-4-1 Access the Log Files 1. Start up the system in the usual way. 2. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). 3. Open another command window by entering: xterm & 4. Change to the /export/home/sdc/senovision/logfiles directory where the log files exist, by entering: cd /export/home/sdc/senovision/logfiles 5. List the log files in the /export/home/sdc/senovision/logfiles directory, by entering: ls The filenames of the different log files located in the /export/home/sdc/senovision/logfiles directory appear. 5-4-2 Compress the Log Files If the required files appear to be too large to fit on a floppy disk, they can be compressed as follows: 1. Create a temporary directory in the /export/home/sdc/senovision/logfiles directory in which log files are to be compressed, by entering: mkdir temp 2. Enter the following commands to copy the log files into the temporary (/export/home/sdc/senovision/ logfiles/temp) directory. The working directory must have been set to logfiles as described above. Omit commands for log files which do not require compressing: a. Copy the error.log file by entering: cp error.log temp b. Copy the ExamEvents.log file by entering: cp ExamEvents.log temp c. Copy the ImageMeasures.log file by entering: cp ImageMeasures.log temp d. Copy the SenoServer.log file by entering: cp trace.SenoServer.log temp e. Copy the trace.Positioner.log file by entering: cp trace.Positioner.log temp f. Copy the PoseidonEvents.log file by entering: cp PoseidonEvents.log temp g. If the error.log.back file exists, copy it by entering: Chapter 9 Page no. 1002 JC-DIAG-A-005.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A005 - Error Log Retrieval cp error.log.back temp h. If you want the older log files, copy them by entering: cp trace.SenoServer.log.xxxxxxxxxxxxxx i. If you want the older archived log files, copy them by entering: cp oldfiles/trace.SenoServer.log.xxxxxxxxx.Z 3. Change to the temporary (/export/home/sdc/senovision/logfiles/temp) directory, by entering: cd temp 4. Compress all of the files in the temporary (/export/home/sdc/senovision/logfiles/temp) directory, by entering: compress * 5. If any of the resulting files exceed the size of a floppy disk, they can be divided into smaller parts by using the split command. For example, to split the file ExamEvents.log.Z into parts smaller than 1.3 Mbyte, enter the following command: split -b 1300 k ExamEvents.log.Z This generates two part files: ExamEvents.log.Z.01 and ExamEvents.log.Z.02 Each of the part files can then be copied to floppy as for the original files. 5-4-3 Copy Log Files to Floppy Disk Copy the required files to a floppy disk as follows: 1. Insert a formatted disk in the floppy drive. 2. Log in as root as follows: a. At the prompt, enter: su - root b. When requested to specify the root password, enter: operator 3. Mount the floppy drive device as /floppy by entering: mount -F pcfs /dev/fd0 /floppy 4. Change to the temporary (/export/home/sdc/senovision/logfiles/temp) directory where the compressed log files exist, by entering: cd /export/home/sdc/senovision/logfiles/temp 5. For each required log file, enter the following command to copy the appropriate file to floppy disk: cp .log.Z /floppy For each file, replace the string by the appropriate file name. To copy non-compressed files, omit the characters .Z from the command. 5-4-4 Completion After copying all required log files, perform the following steps to eject and unmount the floppy disk, and to remove the compressed log files you created. 1. Return to the root directory by entering: cd 2. Eject the floppy disk by entering: eject 3. Unmount the floppy device by entering: umount /floppy 4. Close the xterm window by entering: Page no. 1003 JC-DIAG-A-005.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A005 - Error Log Retrieval exit 5. Change to the logfiles (/export/home/sdc/senovision/logfiles) directory where the temp directory exists, by entering: cd /export/home/sdc/senovision/logfiles 6. Remove all the files in the /export/home/sdc/senovision/logfiles/temp directory, by entering: rm temp/* 7. Remove the /export/home/sdc/senovision/logfiles/temp directory, by entering: rmdir temp 8. Close the xterm window by entering: exit Send the floppy disks containing the saved log files to your engineering contact. Chapter 9 Page no. 1004 JC-DIAG-A-005.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A010 - No Lift or Rotation Movement Job Card DIAG A010 - No Lift or Rotation Movement 1 Chapter 9 INTRODUCTION This Job Card is intended as an aid to troubleshooting when no lift or rotation movement is possible. 1-1. Schematic Concept of the Components Surrounding the H-Bridge The following diagram shows a schematic concept of the components which control the H-Bridge on the Lift DC Board PL201 and the Rotation DC Board PL202. This diagram is intended to provide operational concepts rather than an actual circuit diagram. The layout of the Lift DC Board and the Rotation DC Board can be found in Gantry Board Indicators and Fuses on page 286. The H-Bridge is a group of components which includes a motor in the center and a MOS switch on each branch. The bold lines in the diagram below define the branches of the H-Bridge. The direction of the motor is determined by the pair of MOS switches that are closed (i.e. c for clockwise and a for anticlockwise). Movement is achieved by applying 48 V DC to the motor. DS4 +48 V MOS 48 V DC Switch Microprocessor DS8 a c MOS Drive Movement request a Motor c +0 V H-Bridge When there is a lift or rotation movement request by an Operator of the Senographe system, the Microprocessor does the following: • gets the MOS Drive to close the appropriate pair of MOS switches on the H-Bridge (known as a movement request) • closes the MOS 48 V DC Switch to supply the H-Bridge with 48 V The microprocessor controls the states of the DS4 and DS8 diodes on the Lift DC Board and the Rotation DC Board. The states of the DS4 and DS8 diodes vary according to the different situations that can exist, and are summarized in the following table. Situation If 48 V DC supply is ok Diode state H-Bridge health Movement DS4 DS8 OK Yes ON OFF OK No OFF ON Faulty No Initially ON then OFF ON Page no. 1005 JC-DIAG-A-010.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card DIAG A010 - No Lift or Rotation Movement If there is no lift or rotation motion, you can check to see whether the H-Bridge is faulty by using the following steps: 1. Request a rotation or lift movement on the Senographe. 2. Immediately observe the DS4 and DS8 diodes on the DC Node Board. If the H-Bridge is faulty then the: • DS8 diode remains on all of the time • DS4 diode is initially on while the microprocessor assesses whether there is a rotation or lift movement, and after a time-out the DS4 diode turns off If the H-Bridge is faulty change the appropriate board (see Job Card D/R A221 - Rotation Board on page 1223 or Job Card D/R A201 - Lift Board on page 1161). If the H-Bridge is not faulty then another component in the system is faulty. Chapter 9 Page no. 1006 JC-DIAG-A-010.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Troubleshooting guides TROUBLESHOOTING GUIDES CHAPTER 9 Troubleshooting information is given in the following modules: - Job Card TSG A001 - AWS Troubleshooting - No Display on Power Up on page 1009 Job Card TSG A007 - Digital Detector Firmware Corrupted on page 1015 Job Card TSG A009 - AWS Bootup Troubleshooting on page 1017 Job Card TSG A012 - Use of DB9 Adaptors to Reduce Intermittent IDC or ADS Communication Errors on page 1029 Job Card TSG A015 - Lift Movement Troubleshooting on page 1035 Job Card TSG A016 - Rotation Movement Troubleshooting on page 1059 Job Card TSG A020 - Generator Power-Up Sequence Flow Charts on page 1069 Job Card TSG A027 - 080/011 Error Trouble Shooting on page 1083 Page no. 1007 TSG.FM Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Troubleshooting guides This page is blank. Chapter 9 Page no. 1008 TSG.FM GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A001 - AWS Troubleshooting - No Display on Power Up Job Card TSG A001 - AWS Troubleshooting - No Display on Power UpChapter 9 1 INTRODUCTION This Job Card is intended as an aid to troubleshooting Acquisition Workstation (AWS) start-up problems. It must be used when a fault prevents the AWS or its monitor from powering up, or if a monitor problem makes the display unreadable. In such circumstances, the usual error messages and on-board help files are not usable. The flow charts on the following pages suggest service actions (checks or corrective actions) to be taken in response to observed symptoms. The order in which the actions are given is intended to optimize troubleshooting efficiency. The actions take into account the probability of possible causes, and the time and cost required for the suggested service actions. Page no. 1009 JC-TSG-A-001.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A001 - AWS Troubleshooting - No Display on Power Up 1-1 Troubleshooting Entry Problem with AWS power up and boot process AWS Cabinet appears to power up correctly? Yes No Check UPS operation: See Job Card CHK A003 on page 1737. Good display on monitor? No Is the UPS running on battery? (no AC power input) Yes No Go to monitor adjustments and power checks on page 1012 Is the UPS battery charge too low? Yes Check that the AC power cord is properly connected to system and to wall receptacle. Check that the wall receptacle is supplying power. If the presence of AC power input has been checked, but the system does not power up, the supply can be defective (check voltage, grounding, etc.). Charge the UPS battery No Is the UPS faulty? Yes Change the UPS. No Is the Main Distribution Rack LED lit? No Yes Check circuit breaker and pushbutton settings in the MDR Circuit breaker set off? Yes Set the breaker on. No UPS or Control station push-button set to off? Yes Set the push-button on. No Continue checks on page 1011 Check/change the MDR. Chapter 9 Page no. 1010 JC-TSG-A-001.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A001 - AWS Troubleshooting - No Display on Power Up 1-2 AWS Power Checks From page 1010 UPS and MDR check is good, but AWS does not power up, Is the UPS-AWS power cable incorrectly connected or defective? Yes Correct the cable problem. No Is the MDR-UPS power cable incorrectly connected or defective? Yes Correct the cable problem. No It is likely that the ADS computer PSU is faulty. Plug the ADS computer into a wall socket. If the ADS computer still does not power up and function correctly then the ADS computer PSU is faulty. Is the ADS power supply faulty? No Yes Change the ADS Computer If the problem persists, start again on page 1010, or ask for help from your OLC. Page no. 1011 JC-TSG-A-001.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A001 - AWS Troubleshooting - No Display on Power Up 1-3 Monitor Adjustments and Power Checks From page 1010 AWS apparently powering up correctly, but no display or poor display on monitor. Is there a visible display on the monitor? Yes Refer to LCD GS AWS Monitor Service Manual for actions to correct the display. No Yes Connect the trackball/mouse to the correct USB port (see diagram on page 82). Replace USB extender if necessary. Yes Refer to monitor video signal checks on page 1013 Check the AWS trackball or mouse connection. Is there a problem? No Is the monitor operation LED lit? No Check the monitor power cable. Is it wrongly connected or defective? Yes Reconnect or change the monitor power cable. No Check the monitor fuse. Is it defective? Change the monitor fuse. Yes No If the problem persists, start again on page 1010, or ask for help from your OLC. Chapter 9 Page no. 1012 JC-TSG-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A001 - AWS Troubleshooting - No Display on Power Up 1-4 Monitor Video Signal Checks From page 1012 No display on monitor, but monitor operation LED is lit Check the video cable. Is it defective? Yes Change the video cable. No Check the monitor synchronization cables. Are they defective or wrongly connected? Yes Interchange the H sync. and V sync. cables on the monitor BNC inputs, or change the cables. No Check ADS Computer for video signal problems CPU badly seated? Yes Reseat the CPU. No RAM badly seated? Yes Reseat the RAM. No Defective Graphics card or Motherboard video chip? Change the ADS Computer Yes No If the problem persists, start again on page 1010, or ask for help from your OLC. Page no. 1013 JC-TSG-A-001.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A001 - AWS Troubleshooting - No Display on Power Up This page is blank. Chapter 9 Page no. 1014 JC-TSG-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A007 - Digital Detector Firmware Corrupted Job Card TSG A007 - Digital Detector Firmware Corrupted 1 Chapter 9 SYMPTOMS The detector contains firmware in a PROM mounted on its electronic cards. In certain cases, the IDC can download this firmware when the version of the detector is not compatible with IDC version To verify the detector FW is possibly corrupt, do the following: 1. Restart the IDC by pressing the Reset button on the IDC (on front of the IDC if a Dione5 or at the back of the IDC if a Dione4). 2. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 3. Make a telnet connection with the IDC by entering: telnet idc At the IDC login prompt press the enter key, and at the password prompt press the enter key. A -> prompt appears. 4. If the detector FW is corrupt, the following IDC traces appear with a detector boot error: Detector FW Signature : 0x40080010 DETECTOR boot ERROR => power OFF the Detector (1 mn) Note: You can monitor the boot sequence in a telnet idc window. These symptoms can seem rather like a fiber optics communication failure, for example, or any other failure that prevents IDC from booting. Therefore, you must suspect firmware corruption only if the IDC or the detector has been changed and a software compatibility problem has occurred. 2 SOLUTION There exists a way to force a detector firmware download from IDC to the detector. Apply the following steps if you think that the detector firmware is corrupted: 1. Restart the IDC by pressing the Reset button on the IDC (on front of the IDC if a Dione5 or at the back of the IDC if Dione4). 2. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 3. Make a telnet connection with the IDC by entering: telnet idc At the IDC login prompt press the enter key, and at the password prompt press the enter key. A -> prompt appears. 4. At the -> prompt, type the following command but do not press the return key at this stage to execute it: downloadDetectorFW Some messages appear on the screen indicating that the IDC must be rebooted. 5. Wait for a message on the IDC telnet screen, saying that the IDC will wait for 1 minute before it retries to power on the detector. When you see this message, immediately press the return key to Page no. 1015 JC-TSG-A-007.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A007 - Digital Detector Firmware Corrupted execute the loadDetectorFW command you typed in step 4. The flashing/"firmware write" occurs during this minute. 6. Some messages on the screen indicating that the IDC must be rebooted. 7. At the -> prompt, reboot the IDC by entering: idcReboot The detector should boot normally. Chapter 9 Page no. 1016 JC-TSG-A-007.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A009 - AWS Bootup Troubleshooting Job Card TSG A009 - AWS Bootup Troubleshooting 1 Chapter 9 INTRODUCTION This Job Card is intended as an aid to troubleshooting Acquisition Workstation (AWS) bootup problems. It is used when a bootup fault prevents the AWS booting up correctly. 1-1 Blank Screen after Logging in as the sdc User Once someone has logged in at the first AWS Login: prompt with the sdc user, the monitor goes blank (white with no text or graphics) and then returns to the Login: prompt. This scenario occurs in the following situations: • the mouse or trackball is disconnected • the mouse or trackball is faulty If you witness a blank screen that keeps returning to the Login: prompt after logging in as the sdc user then you must do the following: • Check that the mouse/trackball is correctly attached to the AWS. Check both the connections on the back panel of the ADS computer and on the USB extension cable that connects the mouse/trackball to the ADS computer. • If the problem persists after you have check the cable connections, the mouse/trackball is faulty. You must change the mouse/trackball according to Job Card D/R A312 - Mouse on page 1417 or Job Card D/R A313 - Trackball on page 1427. Page no. 1017 JC-TSG-A-009.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A009 - AWS Bootup Troubleshooting This page is blank. Chapter 9 Page no. 1018 JC-TSG-A-009.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A010 - Troubleshooting Bad Pixel Calibration Failure Job Card TSG A010 - Troubleshooting Bad Pixel Calibration Failure Chapter 9 1 BAD PIXEL CALIBRATION PURPOSE Bad pixel calibration: • Detects pixels that give a signal different from the other pixels on the panel. • Creates a list of the detected pixels to correct them based on the neighbor pixels. If bad pixel calibration failed, it means that the number of detected bad pixels are out of GE internal specifications. 2 IMPACT OF BAD PIXEL CALIBRATION FAILURE If the customer uses a detector having more bad pixels than allowed, there is a risk to loose information in the clinical images. When there are any bad pixel issues (i.e. any bad pixel calibration results fail or there are errors before bad pixel calibration results are displayed), although exposures are still possible, the customer must not use the Senographe system for clinical use until the problem is solved and bad pixel calibration passed. Before the customer uses a Senographe system for clinical use, you must ensure that all the bad pixel calibration results passed. In case of bad pixel calibration failure, follow the bad pixel calibration troubleshooting (see section 3, Bad Pixel Calibration Failure Troubleshooting on page 1019). ! Notice: Even if after a bad pixel calibration failure, the performed Quality Check (QC) or the external quality control test passed, this does not mean that the detector is good. The detected bad pixels are fixed using the neighboring pixels information. Therefore, they do not carry any useful data, but could still hide clinical information. 3 BAD PIXEL CALIBRATION FAILURE TROUBLESHOOTING Bad pixel calibration can fail at one of the following steps: 1. After the first exposure of the calibration called IQ check image 2. At the end of the bad pixel calibration. Page no. 1019 JC-TSG-A-010.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A010 - Troubleshooting Bad Pixel Calibration Failure ILLUSTRATION 1 - HIGH-LEVEL OVERVIEW OF THE BAD PIXEL CALIBRATION PROCESS IQ check image: 6 exposures First exposure Bad pixel calibration can fail here Bad pixel calibration can fail here Display bad pixel calibration results 3-1 Troubleshooting - Failure at the End of IQ Check Image Follow the appropriate sub-section below according to the IQ check test message you received. 3-1-1 IQ Check Test - Median Signal Level The purpose of this test is to check that the system configuration is correct and that the correct phantom has been placed on the detector. If this test fails, the calibration is aborted and the following message appears: "brightness level is not OK" 3-1-1-1 Typical Root Causes 1. The system is not correctly configured for bad pixel calibration (i.e. a compression paddle or a bucky is in place). 2. The kV scale factor of the X-Ray tube is too high or too low. 3. The mAs measurement of the X-Ray tube is too high or too low. 4. The detector temperature is out of range. 3-1-1-2 Corrective Actions 1. Ensure that the bucky is removed, and that no compression paddle is installed. Then perform bad pixel calibration with the flat field phantom as instructed. 2. If the problem persists, perform Check results on page 1670 in Job Card CAL A011 - Calibration of kV Scale Factor, to see if the kV Scale Factor is within the correct limits. If the kV Scale Factor results fail, re-calibrate the kV scale factor according to Job Card CAL A011 - Calibration of kV Scale Factor on page 1667. After kV scale factor calibration has been performed, go to section 4-2, Calibration to be performed after a kV scale factor calibration on page 1026 to execute the other Job Cards in the list. 3. If the problem persists, perform Check results on page 1665 in Job Card CAL A009 - X-Ray Tube mA Measurement , to see if the mAs of the X-Ray tube is within the correct limits. If the mAs results fail, re-calibrate the mAs of the X - Ray tube according to Job Card CAL A009 - X-Ray Tube mA Measurement on page 1663. After the mA calibration has been performed, go to section 4-3, Calibration to be performed after an X-Ray tube mA measurement on page 1027 to execute the other Job Cards Chapter 9 Page no. 1020 JC-TSG-A-010.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A010 - Troubleshooting Bad Pixel Calibration Failure in the list. ! Notice: Make sure to strictly perform all calibration required for correction as stated in section 4, Post-Corrective Actions on page 1026. 3-1-2 IQ Check Test - Object in Field of View The goal of this test is to: • Control if the correct phantom (flat field phantom, 2.5 cm Lucite) is in place and correctly located so that it covers Field of View. • Detect and warn if objects other than the flat field phantom such as the ACR, IQST phantom are in the Field of View. • Detect and warn if highly attenuating objects (such as screwdrivers, screws or other metal objects) are in the Field of View. If this test fails, the calibration is aborted and the following message appears: "Unexpected object in FOV"… 3-1-2-1 Root Cause The system was incorrectly set-up during bad pixel calibration. 3-1-2-2 Corrective Action Ensure that the bucky is removed, that no compression paddle is installed, and that no object is in the Field of View. Then perform bad pixel calibration with the flat field phantom as instructed. 3-1-3 IQ Check Test - Collimator in Field of View The purpose of this test is to check that the collimator is not in the Field of View. If this test fails, the calibration is aborted and the following message appears: "Check collimator for full field of view"… 3-1-3-1 Root cause The collimator is not properly calibrated. 3-1-3-2 Corrective Action Before performing collimator format calibration, all detector calibrations must be cleared. To clear all detector calibrations, follow these steps: 1. From the Service Desktop, select Calibration -> Detector -> Clear Calibrations. 2. Follow the instructions to perform the clear calibrations procedure as indicated. 3. Perform Job Card CAL A029 - Collimator Format Calibration on page 1683 to re-calibrate the collimator. 3-1-4 IQ Check Test - X-Ray Field Shape The purpose of this test is to check the level and uniformity of the image. If this test fails, the calibration is aborted and the following message appears: Page no. 1021 JC-TSG-A-010.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A010 - Troubleshooting Bad Pixel Calibration Failure "Check if paddle is removed and the flat field phantom is positioned correctly"… 3-1-4-1 Typical Root Causes 1. The tube tilt calibration is not good. 2. The X-Ray tube housing is not well positioned on the pivots within the X-Ray tube. 3-1-4-2 Corrective Actions. 1. From the Service Desktop, select Calibration -> Detector -> Clear Calibrations. Follow the instructions to perform the clear calibrations procedure as indicated. 2. Perform Job Card CAL A027 - Tube Tilt Calibration on page 1681, to re-calibrate the tube tilt. 3. If the problem persists, re-position the X-Ray tube housing to ensure that the left pivot is flush against the housing, and that the right pivot has a tight fit. For more information, see Installation of X-ray Tube Housing on page 1355 in Job Card D/R A261 - X-ray Tube Assembly ! Notice: Make sure to strictly perform all calibration required for correction as stated in section 4, Post-Corrective Actions on page 1026. 3-2 Troubleshooting - Failure at the End of Bad Pixel Calibration Bad pixel calibration fails if one or more of the following defect categories have a Fail status: • Isolated pixels • Small clusters • Medium clusters • Large clusters • 3*3 clusters • Bad columns • Bad rows • Small cluster density • Medium cluster density • Local defect density (only for DS and Essential with the International detector). One defect category FAIL means that the detector is above GE bad pixel specifications. The root cause of the failure must be found before the customer can continue to work because there is a risk to loose information in the clinical images. The typical root causes for one or more defect categories to fail in bad pixel calibration are the following: • The detector files are not correct (i.e. there is a detector ID mismatch) • Dust on the detector, flat field phantom, filter wheel, or in the collimator • Damaged flat field phantom • Bad position of flat field phantom • The collimator Blade shadow or the collimator blade itself • Defective detector If bad pixel calibration fails, use the decision tree in Illustration 2, page 1023 along with the following sections to solve the issue. Chapter 9 Page no. 1022 JC-TSG-A-010.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A010 - Troubleshooting Bad Pixel Calibration Failure ILLUSTRATION 2 - DECISION TREE FOR BAD PIXEL CALIBRATION FAILURE Bad Pixel calibration fails NO Detector ID of CSD = Detector ID of Detector CD-ROM or Floppy Disk? Load Detector Parameters (see section 3-2-1, Load Detector Parameters on page 1023) Perform Bad Pixel Calibration (see Job Card CAL A041 - Bad Pixel Calibration on page 1693) Perform post-corrective actions (see section 4-1, Cali- YES bration to be performed after bad pixel calibration on page 1026). YES Setup checks (see section 3-2-2, Setup Checks on page 1023) Perform Bad Pixel Calibration (see Job Card CAL A041 - Bad Pixel Calibration on page 1693) Bad Pixel calibration passes? Bad Pixel calibration passes? YES .End NO NO Collimator blades check (see section 3-2-3, Collimator Blades Check on page 1023) 3-2-1 Load Detector Parameters Check on the Service Desktop home page that the detector ID is the same as the one on the detector CD-ROM or floppy disk. If any doubt, also check that the actual labeling on the detector matches the detector ID written on the detector CD-ROM or floppy disk. • If the detector IDs are the same, return to the troubleshooting decision tree in Illustration 2, page 1023 and continue with the other troubleshooting steps. • If the detector IDs are not the same, reload the detector parameters according to Load Detector Parameters on page 1103 in Job Card D/R A141 - Image Receptor/Digital Detector, then return to the troubleshooting decision tree in Illustration 2, page 1023 and continue with the other troubleshooting steps. 3-2-2 Setup Checks For bad pixel calibration, it is important that: • The flat field phantom used in this procedure is very clean and free from imperfections • All surfaces in the beam (detector, tube, filter, etc.) are very clean and free from imperfections, which can affect calibration. • The flat field phantom is well positioned on the detector: centered laterally, well covered on each detector edge. 3-2-3 Collimator Blades Check If you see a white band on the border(s) of a flat field image, it may be due to the shadow of the collimator blade or the collimator blade itself. Page no. 1023 JC-TSG-A-010.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A010 - Troubleshooting Bad Pixel Calibration Failure 3-2-3-1 Corrective Steps if Bad Pixels are Close to the Detector Edges If you have seen any white band on the border(s) of a flat field image, use the troubleshooting flowchart in the Illustration 3, page 1025. 3-2-3-2 Corrective Steps if no Bad pixel is Close to the Detector Edges If the collimator blades check fail, use the service escalation process. Chapter 9 Page no. 1024 JC-TSG-A-010.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A010 - Troubleshooting Bad Pixel Calibration Failure ILLUSTRATION 3 - STEPS TO PERFORM IF BAD PIXELS EXIST AT DETECTOR EDGES Perform collimator calibration (see Job Card CAL A029 - Collimator Format Calibration on page 1683) Perform Bad Pixel Calibration (see Job Card CAL A041 - Bad Pixel Calibration on page 1693) Perform post-corrective actions (see section 4-1, Calibration to be performed after bad pixel calibration on page 1026). YES Bad Pixel calibration passes? NO 1. 2. 3. Adjust the Collimator positioning. Perform collimator calibration (see Job Card CAL A029 - Collimator Format Calibration on page 1683) Perform Bad Pixel Calibration (see Job Card CAL A041 - Bad Pixel Calibration on page 1693) Perform post-corrective actions (see section 4-1, Calibration to be performed after bad pixel calibration on YES page 1026). Bad Pixel calibration passes? NO 1. 2. 3. Change the Collimator (see Job Card TSG A010 - Troubleshooting Bad Pixel Calibration Failure on page 1019) Perform collimator calibration (see Job Card CAL A029 - Collimator Format Calibration on page 1683) Perform Bad Pixel Calibration (see Job Card CAL A041 - Bad Pixel Calibration on page 1693) Perform post-corrective actions (see section 4-1, Calibration to be performed after bad pixel calibration on page 1026). YES Bad Pixel calibration passes? NO The customer must not use the system. Use the service escalation process. Page no. 1025 JC-TSG-A-010.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A010 - Troubleshooting Bad Pixel Calibration Failure 3-2-3-3 Collimator Adjustment When repositioning the collimator, make sure that you rotate the arm to +180°. For more information on the screw positions that fix the collimator to the tube head frame, see Job Card D/R A280 - Collimator Set on page 1369. ! Notice: Make sure to strictly perform all calibration required for correction as stated by section 4, Post-Corrective Actions on page 1026. 4 POST-CORRECTIVE ACTIONS 4-1 Calibration to be performed after bad pixel calibration Calibration/Test Job Card Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 Flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR test is not OK, repeat all calibrations from AOP Calibration 4-2 Calibration to be performed after a kV scale factor calibration Calibration/Test Job Card kV Scale Factor Calibration Job Card CAL A011 - Calibration of kV Scale Factor on page 1667 X-Ray Tube Heater current Calibration Job Card CAL A012 - X-Ray Tube Heater Current on page 1673 Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 Flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR test is not OK, repeat all calibrations from AOP Calibration Chapter 9 Page no. 1026 JC-TSG-A-010.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A010 - Troubleshooting Bad Pixel Calibration Failure 4-3 Calibration to be performed after an X-Ray tube mA measurement Calibration/Test DS and Essential Job Card X-Ray Tube mA Measurement Job Card CAL A009 - X-Ray Tube mA Measurement on page 1663 X-Ray Tube Heater current Calibration Job Card CAL A012 - X-Ray Tube Heater Current on page 1673 Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 Flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR test is not OK, repeat all calibrations from AOP Calibration 4-4 Calibration to be performed after repositioning the X-Ray tube housing Calibration/Test Job Card Tube Tilt Calibration Job Card CAL A027 - Tube Tilt Calibration on page 1681 Collimator Format Calibration Job Card CAL A029 - Collimator Format Calibration on page 1683 Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 Flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR test is not OK, repeat all calibrations from AOP Calibration Page no. 1027 JC-TSG-A-010.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A010 - Troubleshooting Bad Pixel Calibration Failure 4-5 Calibration to be performed after tube tilt calibration Calibration/Test Job Card Tube Tilt Calibration Job Card CAL A027 - Tube Tilt Calibration on page 1681 Collimator Format Calibration Job Card CAL A029 - Collimator Format Calibration on page 1683 Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 Flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR test is not OK, repeat all calibrations from AOP Calibration 4-6 Calibration to be performed after changing or moving the collimator Calibration/Test Job Card Collimator Format Calibration Job Card CAL A029 - Collimator Format Calibration on page 1683 Collimation Checks Job Card ELE A028 - Collimation Checks on page 679 If Collimator Check is not OK, repeat Collimator Calibration Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 Flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 If AOP/SNR test is not OK, repeat all calibrations from AOP Calibration 4-7 Calibration to be performed after collimator format calibration Calibration/Test Job Card Collimation Checks Job Card ELE A028 - Collimation Checks on page 679 If Collimator Check is not OK, repeat Collimator Calibration Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 If AOP/SNR test is not OK, repeat all calibrations from AOP Calibration Chapter 9 Page no. 1028 JC-TSG-A-010.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A012 - Use of DB9 Adaptors to Reduce Intermittent IDC or ADS Communication Errors Job Card TSG A012 - Use of DB9 Adaptors to Reduce Intermittent IDC or ADS Communication Errors Chapter 9 1 SUMMARY 1-1 Problem The size of the serial connector housing (1) in conjunction with the limited space in between the electronic boards and the housing of the IDC or ADS (2) can cause poor electrical connection on the serial and RT cables within the system. ILLUSTRATION 1 - DB9 PLUG AND SOCKET 2 1 This poor connection can cause intermittent connection failures, resulting in one or more of the following IDC and/or ADS errors listed in Table 1 being raised intermittently. TABLE 1 - IDC AND ADS ERRORS THAT CAN OCCUR INTERMITTENTLY DUE TO CONNECTION ISSUES E05 (079/013) - Failure Before Exposure E18 (094/006) - IDC/Seno synchro failure IDC Error codes E19 (092/000) - I19 IDC/Seno comm. lost. E19 (092/001) - IDC/Seno down, DPS is off. E19 (092/003) - IDC/Seno down, DPS is off E24 (084/013) - Failure before exposure. Error code number 10 - Failure accessing hardware key ADS Error codes I17 (083/002) - AWS/SENO Comm. lost E16 (079/017) - AWS/SENO Synchro fail Error code number 7 - Communication problem with UPS Note : The intermittent ADS error codes due to poor connections only occur on either the U20 or Z400 ADS Computer. The SB-150 ADS Computer does not suffer from poor connections. 1-2 Purpose The purpose of this Job Card is fix intermittent communication faults, and stop the IDC and/or ADS errors listed in Table 1 from being raised intermittently by the system. 1-3 Solution On sites having one or more of the IDC and/or ADS errors listed in Table 1 being raised intermittently, order the DB9 Adaptor Kit (5420609), and install the adaptors on the 9-pin D connectors on the IDC and ADS as described in section 8, Procedure on page 1031. Page no. 1029 JC-TSG-A-012.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A012 - Use of DB9 Adaptors to Reduce Intermittent IDC or ADS Communication Errors The DB9 Adaptor Kit contains eight DB9 straight male/female adaptors that will improve the electrical connection on the serial and RT cables within the system. ILLUSTRATION 2 - DB9 STRAIGHT MALE/FEMALE ADAPTORS Female Side 2 Male Side APPLICABILITY Perform this Job Card only if your other previous trouble-shooting attempts have failed to resolve the IDC and/or ADS errors listed in Table 1. 3 SUPPLIES DB9 Adaptor Kit (5420609). 4 TOOLS Standard Tool Box (including a small flat screwdriver). 5 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 25 to 40 minutes including all functional checks 6 SAFETY PRECAUTIONS None. 7 • • PREREQUISITES Shut down the system and switch off the Generator hospital supply circuit breaker. Remove Control Station omega cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. Chapter 9 Page no. 1030 JC-TSG-A-012.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A012 - Use of DB9 Adaptors to Reduce Intermittent IDC or ADS Communication Errors 8 PROCEDURE 8-1 Put the DB9 Connectors on the IDC On the rear side of the IDC, perform the following steps for installing the DB9 adaptors for each of the 9 pin connectors summarized in Table 2 and Illustration 3. Note: Perform the steps below cable by cable in order to avoid connection to wrong port on the IDC. 1. Unscrew the DB9 cable connector using a screwdriver, and disconnect the DB9 cable. 2. Insert the DB9 adaptor, and tighten the two screws progressively to obtain a good contact. 3. Plug back the DB9 cable and tighten the two screws of the DB9 cable connector progressively to obtain good contact with the DB9 adaptor. Page no. 1031 JC-TSG-A-012.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A012 - Use of DB9 Adaptors to Reduce Intermittent IDC or ADS Communication Errors TABLE 2 - IDC DB9 CONNECTIONS DB9 cable connection reference in illustration Cable Label 1 IDC - Gantry Conditioner Link 2226612 2 Detector Power Supply 2226621 3 IDC - Gantry Serial Link RT 2240227 or 2246615 ILLUSTRATION 3 - IDC DB9 CABLE CONNECTIONS Dione4 3 1 2 Dione5 2 3 1 Chapter 9 Page no. 1032 JC-TSG-A-012.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A012 - Use of DB9 Adaptors to Reduce Intermittent IDC or ADS Communication Errors 8-2 Put the DB9 Adaptors on the ADS Computer On the rear side of the ADS Computer (U20/Z400 only), perform the following steps for installing the DB9 adaptors for each of the 9 pin connectors summarized in Table 3 and Illustration 4. Note: 1. Perform the operations below cable by cable in order to avoid connection to wrong port on the ADS Computer. 2. The intermittent ADS error codes due to poor connections only occur on either the U20 or Z400 ADS Computer. The SB-150 ADS Computer does not suffer from poor connections. 1. Unscrew the DB9 cable connector using a screwdriver, and disconnect the DB9 cable. 2. Insert the DB9 adaptor, and tighten the two screws progressively to obtain a good contact. 3. Plug back the DB9 cable and tighten the two screws of the DB9 cable connector progressively to obtain good contact with the DB9 adaptor. TABLE 3 - ADS DB9 CONNECTIONS DB9 cable connection reference in illustration Cable Label 1 Generator Serial Link 2226625 2 Service key cable 3 Generator-UPS-ADS Serial Link 2387162 ILLUSTRATION 4 - ADS DB9 CONNECTIONS 1 2 3 1 3 2 Z400 Computer (V4 Control Stations) U20 Computer (V3 Control Stations) Page no. 1033 JC-TSG-A-012.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A012 - Use of DB9 Adaptors to Reduce Intermittent IDC or ADS Communication Errors 9 COMPLETION 1. Switch off the Generator hospital supply circuit breaker, power up the system, and login. 2. Open the Status Panel by doing one of the following actions, and check the system is functional: • For V1/V2/V3 Control Stations, press down the meta (♦) key and the F1 key at the same time. • For V4 Control Stations, press down the Windows (á) key and the F1 key at the same time. 3. From the Service Desktop, perform IDC diagnostics (not requiring inserting the loopback-kit connectors) and communication checks to ensure the connectivity is correct. Check ADS connectivity and that no errors are reported. To do this, use the following sub-steps: a. From the Browser, launch the Service Desktop (see Launching the Service Desktop on page 120). b. From the Service Desktop, click the Diagnostics button . c. Run the tests described below by selecting the appropriate button for each test required: AWSDMR, IDC-Conditioner, IDC-DPS and IDC-DMR. 4. Perform three acquisitions and check that image displays correctly 5. Shut down the system. 6. Reinstall the Control Station omega cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. Chapter 9 Page no. 1034 JC-TSG-A-012.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting Job Card TSG A015 - Lift Movement Troubleshooting 1 Chapter 9 INTRODUCTION This Job Card is intended as an aid to troubleshooting Lift movement problems, associated with the following Lift errors: • 102/013 - Lift Overspeed (HALT) • 102/014 - Lift Low Speed (WARNING) • 102/024 - Uncontrolled Lift Motion (HALT) 1-1 FRU to Error Code Matrix The following table generically lists the potentially faulty FRUs in order of highest to lowest probability, depending on the Lift error raised. Lift Error Potential Faulty 102/013 - Lift Overspeed (HALT) 1. Grease (for Lift and Rotation) (correct application of) 2. Lift Gas Spring 3. Lower Lift Screw Bearing (indication of failure can be abnormal noise and vibration without any of the displayed errors) 4. Lift screw assembly 5. Lift motor 6. Lift board 102/014 - Lift Low Speed (WARNING) 102/024 - Uncontrolled Lift Motion (HALT) Note 1: Only Grease for Lift and Rotation (5212483) (Orapi CT FLON 607) must ever be used on the Gantry. Use of other types of grease are not permitted on the Gantry since they may have different characteristics than that required. Note 2: The Lower Lift Screw Bearing is no longer a FRU. If in the tests below you deduce the Lower Lift Screw Bearing is faulty, change the entire Lift Screw Assembly. Note 3: The actual FRUs to order depend on the Type of Lift Screw Assembly in the system, and the nature of these errors. For more information to know which FRUs to take during an onsite troubleshooting visit, see section 1-3, Preparing the FRUs to take for a troubleshooting onsite visit on page 1041. Page no. 1035 JC-TSG-A-015.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting 1-2 Lift Type Identification and Related FRU Compatibility Matrix 1-2-1 Identifying Lift Screw Assembly Types Three Lift Screw Assembly types (in terms of brake functionality) exist in the install base as follows: • Type 1: No brake - (stationary systems only) - the oldest of the systems in the install base dating back to January 2008 and earlier. At this stage of the product life cycle no brake was required because the system was only available for stationary (hospital room) scenarios. A system containing a Type 1 Lift Screw Assembly with "No brake" can be identified as follows: - the black L-bracket at the top of the Lift Screw Assembly - the motor at bottom of the Lift Screw Assembly only has power cables and does not have an earth cable • Type 2: Top brake compatible- (stationary and mobile systems) - the middle age systems in the install base dating between January 2008 and June 2011. At this stage of the product life cycle, brake capability was required because the Senographe Essential system was made available for mobile (van) scenarios. A "top brake" was designed to be installed at the top of the Lift Screw Assembly. Forward production Gantries (from January 2008) were produced with a Type 2 Lift Screw Assembly that had a silver L-bracket with threaded holes to support the installation of the "top brake", and an earth cable leaving the Motor. The Senographe Essential Mobile Kit included the "top brake", which was installed on Mobile Systems. A system containing a Type 2 Lift Screw Assembly can be identified by: - the sliver L-bracket with threaded holes at the top of the Lift Screw Assembly, and the "top brake" (if it is installed which is the case on Mobile systems) - in addition to the power cables, the motor at the bottom of the Lift Screw Assembly contains an earth cable, but no brake cable The Type 2 Top brake compatible Lift Screw Assembly is divided into two type 2s (2a and 2b): - Type 2a: Applies to a stationary system in hospital which has NO top brake installed. - Type 2b: Applies to a system that has the top brake mounted. It can either be a mobile system or a stationary system that required the top brake to resolve lift motion errors Type 2a Chapter 9 Type 2b Page no. 1036 JC-TSG-A-015.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting Note: You can normally identify whether the top brake is installed without removing the Gantry covers due to its distinctive clamping noise. When stopping the Gantry lift movement, a distinctive clamping noise can be heard almost immediately after letting go of the lift control buttons. Type 3: Brake motor - (stationary and mobile systems) - the latest systems in the install base dating from June 2011 onwards. At this stage of the product life cycle, brake functionality was considered a product improvement. All Gantries manufactured from June 2011 were installed with a Type 3 Lift Screw Assembly containing the "brake motor". A system containing a "brake motor" can be identified by: - the sliver block with no threaded holes at the top of the Lift Screw Assembly - in addition to the power cables, the motor at the bottom of the Lift Screw Assembly contains an earth cable and a brake cable Page no. 1037 JC-TSG-A-015.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting Table 1 provides a summary for quickly identifying the type of Lift Screw Assembly that is installed in the Gantry. TABLE 1 - LIFT SCREW ASSEMBLY TYPE IDENTIFICATION QUICK GUIDE Lift Type in Install Base System Type 1 (No brake) Type 2 (Top brake compatible) Type 3 (Brake motor) Type 2a (no top brake) Type 2b (with top brake) pre-January 2008 January 2008 January 2008 June 2011 Bracket at top of Lift Screw Assembly Black with no threaded holes Silver with threaded holes Black with no threaded holes Silver with no threaded holes Motor power cable YES YES YES YES Motor earth cable NO YES YES YES Motor brake cable NO NO NO YES Manufacturing Date Physical Identification Method (required on Type 1 or Type 2 systems to know if Lift Screw Assembly upgraded to newer type) When troubleshooting the lift it is important to identify which type of Lift Screw Assembly is installed in the system. If you do not have a Type 3 Lift Screw Assembly (June 2011 and later), you will have to consult your service records to see if a Type 1 or Type 2 Lift Screw Assembly has been changed for a later type, and if the service records are not clear you will need to remove the Gantry column covers to observe the bracket at top of the Lift Screw Assembly and determine the Lift Screw Assembly Type installed according to Table 1. 1-2-2 FRU Compatibility Matrix Depending on Lift Screw Assembly Type Table 2 on page 1039 describes how the existing Lift FRUs can be applied/ordered for depending on the Lift Screw Assembly type installed in the Gantry. For more information on the different Lift Screw Assembly types, see section 1-2-1, Identifying Lift Screw Assembly Types on page 1036. Chapter 9 Page no. 1038 JC-TSG-A-015.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting TABLE 2 - LIFT RELATED FRU COMPATIBILITY MATRIX FRU compatibility with IB systems [YES/NO] Lift Type in Install Base System No brake (Type 1) Top brake (Type 2) Brake motor (Type 3) Type 2a (no top brake) Type 2b (with top brake) FRU P/N Description 5191096 (Obsolete) Lift Screw Assembly (Type 2) with Motor Obsolete Obsolete Obsolete NO 5212900 Brakeless Lift Motor * YES YES YES NO 5391083 Lift Screw (Type 2) without Motor YES YES YES NO 5373048 Lift Screw (Type 3) without Motor * YES YES NO YES 5413527 Lift Brake Motor (Type 3) NO NO NO YES 5337148 Lift Screw Assembly (Type 3) with Motor YES** YES** YES** YES 5198687 Lift Top Brake Assembly Kit NO YES YES NO Notes: * - The Lift Screw (Type 3) without Motor is compatible with both the Brakeless Lift Motor (5212900) and the Lift Brake Motor (5413527). However, a system already containing the Lift Brake Motor (5413527) must never be downgraded with a Brakeless Lift Motor (5212900). ** - This FRU can be used as upgrade kit to brake motor design lift When following the troubleshooting below consider this compatibility matrix. Page no. 1039 JC-TSG-A-015.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting When using this trouble shooting guide, use illustration 1 to help identify the parts on the Lift. ILLUSTRATION 1 - GANTRY PARTS Lift Screw Assembly Ball Bearing Ring Lift Screw Assembly Lift Upper Optical Fork Rotation Brake Lift Cardan Nut Assembly Lift Screw Assembly Lower Ball Bearing Ring Lift Gas Spring Lift Board Lift Lower Optical Fork Lift Potentiometer Lift Motor & Encoder Can also include an integrated brake Chapter 9 Page no. 1040 JC-TSG-A-015.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting 1-3 Preparing the FRUs to take for a troubleshooting onsite visit Before going onsite to troubleshoot and change parts in the Lift, it is important to know which type of Lift Screw Assembly is installed in the system, and the nature of the errors. Knowing this information allows you to determine which parts to take onsite. Table 3 summarizes the parts to take onsite according to the Lift Screw Assembly type and nature of the errors. The parts listed in table Table 3 are in the order (from top to bottom) in which they are used in the troubleshooting flowcharts below. TABLE 3 - FRUS TO TAKE ON SITE DEPENDING ON LIFT TYPE AND NATURE OF ERRORS REPORTED Does customer complain about Error 102/024 or does Error 102/024 repeatly appear in the error logs? Yes Type 1 Lift Screw Assembly • Type 3 Lift Screw Assembly with Brake Motor (5337148) • Lift Gas Spring No • Lift Gas Spring • Type 3 Lift Screw Assembly with Brake Motor (5337148) • Lift Board Does customer complain about Error 102/024 or does Error 102/024 repeatly appear in the error logs? Yes Type 2 Lift Screw Assembly Are Errors 102/013 and 102/014 present on a weekly basis? Yes • Type 3 Lift Screw Assembly with Brake Motor (5337148) • Lift Gas Spring No • Lift Top Brake (5198687) • Lift Gas Spring • Type 2 Lift without Motor (5391083) • Brakeless Lift Motor (5212900) • Lift Board No • Lift Gas Spring • Type 2 Lift without Motor (5391083) • Brakeless Lift Motor (5212900) • Lift Board Does customer complain about Error 102/024 or does Error 102/024 repeatly appear in the error logs? Type 3 Lift Screw Assembly • • • • Yes Lift Brake Motor (5413527) Lift Gas Spring Type 3 Lift without Brake Motor (5373048) Lift Board Page no. 1041 JC-TSG-A-015.fm No • Lift Gas Spring • Type 3 Lift without Brake Motor (5373048) • Lift Brake Motor (5413527) • Lift Board Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting 2 TROUBLESHOOTING STEERING GUIDE The troubleshooting steering guide to use depends on the type of Lift Screw Assembly installed in the system. Determine the type of Lift Screw Assembly that is installed in the system according to section 12, Lift Type Identification and Related FRU Compatibility Matrix on page 1036. Then use one of the following three sub-sections according to the Type of Lift Screw Assembly installed in the Gantry: 2-1 Trouble Shooting Steering Guide For Type 1 Lift Screw Assembly Use the following flow charts (illustration 2 and illustration 3) to isolate the issue causing the Lift movement problems on systems with a Type 1 Lift Screw Assembly. ILLUSTRATION 2 - LIFT TROUBLESHOOTING ENTRY - TYPE 1 LIFT SCREW ASSEMBLY Does customer complain about Error 102/024 or does Error 102/024 repeatly appear in the error logs? No Yes Perform the lift trouble shooting steps described in illustration 3, Troubleshooting Flowchart For Lift Movement Problems Related to Errors 102/ 013 and 102/014 - Type 1 Lift Screw Assembly on page 1043 Install Type 3 Lift Screw Assembly with Brake Motor (5337148) See Job Card D/R A232 - Lift Screw Assembly on page 1255 Note: The brake functionality requires the old system to have 2373567-8 Lift Board and Lift CPLD version 10.0.1 or above. Check the Service Desktop home page and if the Lift Board CPLD version is less than 10.0.1 you must also change the Lift Board according to Job Card D/R A201 - Lift Board on page 1161. Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. After the checks, return back here. OK OK NOK Lift Gas Spring Checks See section 3-4, Lift Gas Spring Checks on page 1052. OK OK NOK Change Lift Gas Spring See Job Card D/R A206A - Lift Gas Spring on page 1183. Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. OK OK NOK Contact OLC. Chapter 9 Page no. 1042 JC-TSG-A-015.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting ILLUSTRATION 3 - TROUBLESHOOTING FLOWCHART FOR LIFT MOVEMENT PROBLEMS RELATED TO ERRORS 102/013 AND 102/014 - TYPE 1 LIFT SCREW ASSEMBLY Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. NOK Grease Checks See section 3-2, Grease NOK Checks on page 1048. Corrective actions Grease Lift Screw See section 3-3, Grease Lift Screw on page 1049. OK Lift Gas Spring Checks See section 3-4, Lift Gas Spring NOK Checks on page 1052. Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. OK NOK Change Lift Gas Spring See Job Card D/R A206A - Lift Gas Spring on page 1183. OK Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. OK NOK Change the Lift Screw Assembly with Motor (5391083 + 5212900) See Job Card D/R A232 - Lift Screw Assembly on page 1255. Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. OK NOK Change Lift Board See Job Card D/R A201 - Lift Board on page 1161. Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. OK NOK Contact OLC. Page no. 1043 JC-TSG-A-015.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting 2-2 Trouble Shooting Steering Guide For Type 2 Lift Screw Assembly Use the following flow charts (illustration 4 and illustration 5) to isolate the issue causing the Lift movement problems on systems with a Type 2 Lift Screw Assembly. ILLUSTRATION 4 - LIFT TROUBLESHOOTING ENTRY - TYPE 2 LIFT SCREW ASSEMBLY Does customer complain about Error 102/024 or does Error 102/024 repeatly appear in the error logs? Yes Yes No Perform the lift trouble shooting steps described in illustration 5, Troubleshooting Flowchart For Lift Movement Problems Related to Errors 102/ 013 and 102/014 - Type 2 Lift Screw Assembly on page 1045 Are Errors 102/013 and 102/014 present on a weekly basis? No Install Type 3 Lift Screw Assembly with Brake Motor (5337148) See Job Card D/R A232 - Lift Screw Assembly on page 1255 Note: The brake functionality requires the old system to have 2373567-8 Lift Board and Lift CPLD version 10.0.1 or above. Check the Service Desktop home page and if the Lift Board CPLD version is less than 10.0.1 you must also change the Lift Board according to Job Card D/R A201 - Lift Board on page 1161. Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. After the checks, return back here. OK OK NOK Lift Gas Spring Checks See section 3-4, Lift Gas Spring Checks on page 1052. OK OK NOK Perform Lift Functional Checks. See section 3-1, Lift Functional OK Checks on page 1048. After the checks, return back here. OK NOK Proceed to the Grease Checks in illustration 5, and follow the flowchart as required. Change Lift Gas Spring See Job Card D/R A206A - Lift Gas Spring on page 1183. Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. Install/change Top Brake (5198687) - See Job Card D/R A233 - Lift Screw Assembly Top Brake Requires the old system to have 2373567-8 Lift Board and Lift CPLD version 10.0.1 or above OK OK NOK Contact OLC. Chapter 9 Page no. 1044 JC-TSG-A-015.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting ILLUSTRATION 5 - TROUBLESHOOTING FLOWCHART FOR LIFT MOVEMENT PROBLEMS RELATED TO ERRORS 102/013 AND 102/014 - TYPE 2 LIFT SCREW ASSEMBLY Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. Corrective actions NOK Grease Checks See section 3-2, Grease NOK Checks on page 1048. Grease Lift Screw See section 3-3, Grease Lift Screw on page 1049. OK Change Lift Gas Spring See Job Card D/R A206A - Lift Gas Spring on page 1183. OK Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. OK NOK NOK If Nut, Bearing or Lift NOK, change for Type 2 Lift without Motor (5391083), keeping the motor from the old lift. See Job Card D/R A232 - Lift Screw Assembly on page 1255. OK Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. OK NOK Change Brakeless Lift Motor (5212900) Check Lift Motor See section 3-6, Lift Motor Checks on page 1057. OK NOK Lift Gas Spring Checks See section 3-4, Lift Gas Spring NOK Checks on page 1052. Nut, Bearing, and Lift Checks See section 3-5, Bearing and Lift Checks on page 1057. Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. NOK See Job Card D/R A205 - Lift Motor on page 1179. Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. OK NOK OK Change Lift Board See Job Card D/R A201 - Lift Board on page 1161. Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. OK NOK Contact OLC. Page no. 1045 JC-TSG-A-015.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting 2-3 TROUBLESHOOTING STEERING GUIDE FOR TYPE 3 LIFT SCREW ASSEMBLY Use the following flow charts (illustration 6 and illustration 7) to isolate the issue causing the Lift movement problems on systems with a Type 3 Lift Screw Assembly. ILLUSTRATION 6 - LIFT TROUBLESHOOTING ENTRY - TYPE 3 LIFT SCREW ASSEMBLY Does customer complain about Error 102/024 or does Error 102/024 repeatly appear in the error logs? No Yes Perform the lift trouble shooting steps described in illustration 7, Troubleshooting Flowchart For Lift Movement Problems Related to Errors 102/ 013 and 102/014 - Type 3 Lift Screw Assembly on page 1047 Replace Brake Motor (5413527) See Job Card D/R A205 Lift Motor on page 1179. Perform Lift Functional Checks. See section 3-1, Lift Functional OK Checks on page 1048. After the checks, return back here. OK NOK Proceed to the Grease Checks in illustration 7, and follow the flowchart as required. Chapter 9 Page no. 1046 JC-TSG-A-015.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting ILLUSTRATION 7 - TROUBLESHOOTING FLOWCHART FOR LIFT MOVEMENT PROBLEMS RELATED TO ERRORS 102/013 AND 102/014 - TYPE 3 LIFT SCREW ASSEMBLY Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. Corrective actions NOK Grease Checks See section 3-2, Grease NOK Checks on page 1048. Grease Lift Screw See section 3-3, Grease Lift Screw on page 1049. OK OK NOK Lift Gas Spring Checks See section 3-4, Lift Gas Spring NOK Checks on page 1052. Change Lift Gas Spring See Job Card D/R A206A - Lift Gas Spring on page 1183. OK Nut, Bearing, and Lift Checks See section 3-5, Bearing and Lift Checks on page 1057. Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. OK NOK If Nut, Bearing or Lift NOK, change Type 3 Lift without Motor (5373048), keeping the motor from the old lift. NOK OK See Job Card D/R A232 - Lift Screw Assembly on page 1255. Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. OK NOK Change Type 3 Lift Motor (5413527) Check Lift Motor See section 3-6, Lift Motor Checks on page 1057. NOK See Job Card D/R A205 - Lift Motor on page 1179. Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. OK NOK Note: If you have just changed the Lift motor as instructed above in illustration 6, the Lift Motor can be assumed to be OK, so proceed directly to OK changing the Lift Board. Change Lift Board See Job Card D/R A201 - Lift Board on page 1161. Perform Lift Functional Checks. See section 3-1, Lift Functional Checks on page 1048. OK NOK Contact OLC. Page no. 1047 JC-TSG-A-015.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting 3 TROUBLESHOOTING STEPS Use the following sub-sections as referenced by the trouble shooting steering guide provided above in section 2, Troubleshooting Steering Guide on page 1042. 3-1 Lift Functional Checks 1. If present, remove the compression paddle. 2. Install the Bucky, and protect the Bucky surface with some paper or similar non abrasive material. 3. Add approximately 13.5 kg (29.8 lbs) of additional weight on the Bucky. Note: If the Stereotaxy Positioner is present, install the Stereotaxy Positioner instead, and add 6 kg (13.2 lbs) of additional weight. 4. Use the high speed Arm Control buttons to drive the Lift over the whole range up and down 10 times in high speed. While moving the Lift over the whole range: a. Check on the Gantry LCD Display whether the following Lift related errors appear: - 102/013 - Lift Overspeed (HALT) - 102/014 - Lift Low Speed (WARNING) - 102/024 - Uncontrolled Lift Motion (HALT) b. Visually check that the speed of the Lift up/down movement is constant. If there are no Lift related errors/warnings and the Lift up/down movement is constant, the Lift functional checks have passed, the corrective action worked, and no further action is required. If there are Lift related errors/warnings and/or the Lift up/down movement is not constant, the Lift functional checks have failed, the corrective action did not work, and you must continue with the troubleshooting tasks back in the appropriate troubleshooting illustration in the section above. 3-2 Grease Checks Visually check the grease on the Lift Screw for the following points: • Distribution of Grease for Lift and Rotation (5212483) (Orapi CT FLON 607) is applied evenly over the entire Lift Screw (see illustration 9 for examples of good greasing). The illustration directly below shows an example of bad greasing. • • The color must be light gray or almost white. If there are any hard points on the Lift Screw. Hard points are difficult to check visually. Use steps 1 to 3 in section 3-1, Lift Functional Checks and check for hard points during the lift movement. Hardpoints are identified by notable and temporary slowing of the lift motion during the lift movement. If the points above have not passed (or you are unsure that the grease is Grease for Lift and Rotation (5212483) (Orapi CT FLON 607) is used on the Gantry) you must grease the Lift Screw as described in section 3-3, Grease Lift Screw. Chapter 9 Page no. 1048 JC-TSG-A-015.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting 3-3 Grease Lift Screw 1. Clean the Lift Screw with a cleaner and a cloth until all of the old grease is fully removed, using the following sub-steps: a. Apply Cleaner Spray to the Lift Screw. Recommended product: 3M Cleaner Spray (3M PN 50098). b. Use ORA Wipes (or equivalent) cloths for removing the grease from the Lift Screw. Rotate the ORA Wipes cloth around the Lift Screw, and along the entire length of the Lift Screw as shown below. Take care not to use the type of cloth wipes that could disintegrate, since the loosened threads or particles may get mixed with the grease. Note: When working with grease, and to protect your hands against the Lift Screw, always wear rubber cloves. Page no. 1049 JC-TSG-A-015.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting Repeat these sub-steps above several times until the Lift Screw is cleaned. A well cleaned Lift Screw looks like that shown below. 2. Apply Grease (for Lift and Rotation) (5212483) (Orapi CT FLON 607) to the Lift Screw by hand. Ensure the Lift Screw is homogeneously covered with grease, as shown in illustration 8. CAUTION Do not use any other type of grease, other than Grease for Lift and Rotation (5212483) (Orapi CT FLON 607). Do not use a brush to apply the grease as this may introduce foreign objects on to the Lift Screw. Only use your hands to apply the grease to the Lift Screw. About 35 g (1.23 oz) of grease is sufficient to cover the entire length of the Lift Screw. Chapter 9 Page no. 1050 JC-TSG-A-015.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting ILLUSTRATION 8 - EXAMPLES OF GOOD AND BAD GREASING OF THE LIFT SCREW Good Uniformly applied grease. Bad Too much applied grease can splatter to column wall. Clean surfaces, walls and cables from spattered grease. 3. Once you have finished applying grease to the entire Lift Screw, use the slow speed Arm Control buttons to drive the Lift over the whole range up and down two times in slow speed. 4. Use the fast speed Arm Control buttons to drive the Lift over the whole range up and down a few times in fast speed. 5. Check how grease has been spread to the screw. Examples of well spread grease, smoothly and uniformly along the whole screw length, with no splattered grease are shown in illustration 9. Page no. 1051 JC-TSG-A-015.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting ILLUSTRATION 9 - EXAMPLES OF WELL APPLIED GREASE AFTER LIFT MOVEMENT If there are some areas where no grease exists, apply grease to these areas, move the Arm again in slow and fast speeds, and check the greasing again. 3-4 Lift Gas Spring Checks 1. Remove the Tube Head covers, Bucky and Compression Paddle. Note: If you do not remove the Tube Head covers, Bucky and Compression Paddle, the Arm assembly will be too heavy for the Lift Gas Spring checks to work. 2. Remove the two springs of curtains from the back of the Gantry. (Using a crook or tiewrap could help). If necessary, move the trolley position so that the springs (1) that attach upper and lower curtains are visible. 1 Chapter 9 Page no. 1052 JC-TSG-A-015.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting 3. Cut the tiewrap fixing the clutch cable to curtain (2). 4. Release and remove the two lower screws securing the lower curtain (3) (3 mm allen wrench). 3 2 5. Remove the lower curtain. 6. Release the two lower screws (4) on the lower part of each of the Curtain Ribs (3 mm allen wrench). 4 5 7. Release the four nuts (5) securing the lower X plate (17 mm open-ended wrench) and remove the lower X-Plate by sliding it under the remaining Curtain Ribs. 8. Use the Arm Control buttons to drive the Lift to its lowest position, so that the bottom of the lift rests Page no. 1053 JC-TSG-A-015.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting on a wood or plastic block. Note: The supporting block(s) must have a total height of between 7.6 cm (3") and 12.7 cm (5"). The supporting block(s) must be at least 7.6 cm (3") wide, and 10 cm (4") to 20 cm (8") long. One or more blocks can be used, but the minimum thickness of each block must be 2.5 cm (1"). The two right hand side fixing screws (6) of the Cardan are visible. 6 9. Release two right hand side Cardan screws (6) from the Cardan (6 mm socket wrench). 10. Release two left hand side Cardan screws (7) from the Cardan. To access these screws from behind Chapter 9 Page no. 1054 JC-TSG-A-015.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting the Rotation board, use a 6 mm socket wrench with universal joint (knuckle joint). 7 Universal joint (knuckle joint) 11. Once the Arm has been disconnected from the Cardan Nut Assembly, lift the exam Arm by hand manually so that the detector upper surface is approximately 1 meter above the floor. If you need lots of force to manually lift the Arm up, do not try to lift the Arm as the Lift Gas Spring is faulty. In this case, just change the Lift Gas Spring according to Job Card D/R A206A - Lift Gas Spring on page 1183. Page no. 1055 JC-TSG-A-015.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting 12. Release the Arm slowly downwards and let it drop down. • If the Arm stays at its current position or moves from its original position and stops at a distance of at least 2 cm (0.79 inches) above the bottom Gantry baseplate (see illustration 10), the Lift Gas Spring is in good condition and does not need changing. • If the Arm moves (slowly or rapidly) down to the Gantry baseplate (see illustration 10), the Lift Gas Spring is defective, and needs changing according to Job Card D/R A206A - Lift Gas Spring on page 1183. ILLUSTRATION 10 - INDICATION OF LIFT GAS SCREW TEST PASS OR FAIL DEPENDING ON POSITION PASS Arm rests at least 2 cm (0.79 inches) above Gantry baseplate. FAIL Arm touches Gantry baseplate. Chapter 9 Page no. 1056 JC-TSG-A-015.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting 3-5 Bearing and Lift Checks Use the following flow chart to determine the corrective actions to take. Lift Functional Checks 1. If present, remove the compression paddle. 2. Install the Bucky, and protect the Bucky surface with some paper or similar non abrasive material. 3. Add approximately 13.5 kg (29.8 lbs) of additional weight on the Bucky. If the Stereotaxy Positioner is present, install the Stereotaxy Positioner instead, and add 6 kg (13.2 lbs) of additional weight. 4. Use the high speed Arm Control buttons to drive the Lift over the whole range up and down 10 times in high speed. IF The lift moves with high speed motion, but the speed changes notably. The lift is sticking or does not move in particular lift position. There is notable or abnormal vibration. The motor frame or lift screw is visibly damaged (bent components etc.). The bearing is noisy. For Type 2 Lift Screw Assembly, change Type 2 Lift without Motor (5391083), keeping the motor from the old lift.. For Type 3 Lift Screw Assembly, change Type 3 Lift without Motor (5373048), keeping the motor from the old lift. The lift moves normally with no abnormal noises or vibrations. Check Lift Motor See section 3-6, Lift Motor Checks. See Job Card D/R A232 - Lift Screw Assembly on page 1255. 3-6 Lift Motor Checks Check cabling connections and connectors on the Lift Board, and the Lift Motor. • If the Lift Motor connectors are not OK, change the Lift Motor according to Job Card D/R A205 - Lift Motor on page 1179. • If the Lift Board connectors are not OK, change the Lift Board according to Job Card D/R A201 - Lift Board on page 1161. • If the cabling connections and connectors are OK but the Lift does not still work, change the Lift Board according to Job Card D/R A201 - Lift Board on page 1161, since it is the last remaining part that can be replaced. Page no. 1057 JC-TSG-A-015.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A015 - Lift Movement Troubleshooting This page is blank. Chapter 9 Page no. 1058 JC-TSG-A-015.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A016 - Rotation Movement Troubleshooting Job Card TSG A016 - Rotation Movement Troubleshooting 1 Chapter 9 INTRODUCTION This Job Card is intended as an aid to troubleshooting Rotation movement problems, associated with the following Rotation errors: • 112/011 - Rotation Overspeed (HALT) • 112/012 - Rotation Lowspeed (WARNING) • 112/023 - Uncontrolled Rotation Motion (HALT) Note: On the Gantry LCD display, these errors display the text Rotation control error next to the error code. 1-1 FRU to Error Code Matrix The following table lists the potentially faulty FRUs starting with the highest occurrence probability down to the lowest one, depending on the raised Rotation error. Rotation Error 112/011 - Rotation Overspeed (HALT) 1. 112/012 - Rotation Lowspeed (WARNING) 2. 3. 112/023 - Uncontrolled Rotation Motion 4. (HALT) 5. Potential Faulty Cabling (bad routing of cables) Grease (for Lift and Rotation) (correct application of) Rotation Gas Spring Rotation board Rotation Motor Note: Only Grease for Lift and Rotation (5212483) (Orapi CT FLON 607) must ever be used on the Gantry. Use of other types of grease are not permitted on the Gantry since they may have different characteristics than that required. Note: The errors in the table above can not be due to a faulty Rotation Gear Gas Spring. Page no. 1059 JC-TSG-A-016.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A016 - Rotation Movement Troubleshooting 2 TROUBLESHOOTING STEERING GUIDE Use the following flow chart to isolate the issue causing the Rotation movement problems. ILLUSTRATION 1 - TROUBLESHOOTING FLOWCHART Perform Rotation Functional Checks. See section 3-1, Rotation Functional Checks on page 1061. Corrective actions NOK Cable Checks See section 3-2, Cable Checks NOK on page 1062. Re-route cables See section 3-3, Cable Re-routing on page 1062. OK OK NOK Grease Checks See section 3-4, Grease NOK Checks on page 1064. Grease Rotation Parts See section 3-5, Grease Rotation Parts on page 1066. OK Perform Rotation Functional Checks. See section 3-1, Rotation Functional Checks on page 1061. OK NOK Rotation Gas Spring Checks See section 3-6, Rotation Gas NOK Spring Checks on page 1067. Change Rotation Gas Spring See Job Card D/R A230 - Rotation Gas Spring on page 1251. OK Check Rotation Motor See section 3-7, Rotation Motor Checks on page 1068. Perform Rotation Functional Checks. See section 3-1, Rotation Functional Checks on page 1061. Perform Rotation Functional Checks. See section 3-1, Rotation Functional Checks on page 1061. OK NOK NOK OK Change Rotation Motor See Job Card D/R A228 - Rotation Motor on page 1243 Change Rotation Board See Job Card D/R A221 - Rotation Board on page 1223. Perform Rotation Functional Checks. See section 3-1, Rotation Functional Checks on page 1061. OK NOK Perform Rotation Functional Checks. See section 3-1, Rotation Functional Checks on page 1061. OK NOK Contact OLC. Chapter 9 Page no. 1060 JC-TSG-A-016.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A016 - Rotation Movement Troubleshooting 3 TROUBLESHOOTING STEPS Use the following sub-sections as referenced by the trouble shooting steering guide provided in illustration 1. 3-1 Rotation Functional Checks 1. Remove the Breast Support. 2. Use the slow speed Arm Control buttons to rotate the Arm over the whole range 5 times in slow speed. While moving the Arm over the whole rotation range (-165° to +185°): a. Check on the Gantry LCD Display whether the following Rotation related errors appear: • 112/011 - Rotation control error • 112/012 - Rotation control error • 112/023 - Rotation control error b. Visually check that the speed of the rotation movement is constant. c. Check if noise is present indicating that the Rotation Motor cables and Rotation Clutch cables are getting stuck with the Arm Covers, etc. If there are no Rotation related errors/warnings and the movement is constant, the Rotational functional checks have passed, the corrective action worked, and no further action is required. If there are Rotation related errors/warnings and/or the movement is not constant, the Rotation functional checks have failed, the corrective action did not work, and you must continue with the troubleshooting tasks in illustration 1. 3. Use the speed Arm Control buttons to rotate the Arm to the start point of the downward motion resistance test (i.e. +90° for the left hand side, and -90° for the right hand side). 4. Use the Tube Head control buttons (A) on the opposite side of the intended downward motion (B), to manually apply a modest upward resistance, while rotating the Arm downwards. Apply the resistance during the entire downward motion (i.e. anti-clockwise from and +90° to +185° when testing the left hand side, and clockwise from -90° to -165° when testing the right hand side). A. Downward motion via fast Arm control buttons (clockwise, right-hand side in this example). B B A A Page no. 1061 JC-TSG-A-016.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A016 - Rotation Movement Troubleshooting 5. While applying resistance during the downward motion, check on the Gantry LCD Display whether the following Rotation related errors appear: • 112/011 - Rotation control error • 112/012 - Rotation control error • 112/023 - Rotation control error If there are no Rotation related errors/warnings during the downward motion resistance test, the corrective action worked, and no further action is required. If there are Rotation related errors/warnings during the downward motion resistance test, the corrective action did not work, and you must continue with the troubleshooting tasks in illustration 1. 3-2 Cable Checks 1. Remove the Gantry column covers. 2. Ensure that the Motor cables W206 and W205 to the Rotation Board (connector J10 and J9) are routed and secured with cable ties as indicated in illustration 2. If they are not routed correctly, reroute them as indicated in section 3-3, Cable Re-routing. 3. Ensure that the clutch cables are correctly positioned, and secured to the spacer of Rotation Board PL202 by a cable tie as indicated in illustration 3.If they are not routed correctly, re-route them as indicated in section 3-3, Cable Re-routing. 4. Use the slow speed Arm Control buttons to rotate the Arm over the whole range in slow speed, and check that the Rotation Motor cables and Rotation Clutch cables are free to move without physical interference from other parts of the Gantry. 3-3 Cable Re-routing Ensure that the Motor cables W206 and W205 to the Rotation Board (connector J10 and J9) are routed and secured with cable ties as indicated in illustration 2. ILLUSTRATION 2 - RECOMMENDED ROTATION MOTOR CABLE ROUTING Cable Tie Cable Tie Chapter 9 Page no. 1062 JC-TSG-A-016.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A016 - Rotation Movement Troubleshooting Ensure that the clutch cables are correctly positioned, and secured to the spacer of Rotation Board PL202 by a cable tie as indicated in illustration 3. ILLUSTRATION 3 - RECOMMENDED ROTATION CLUTCH CABLE ROUTING Use a cable tie (B) to secure the cables at this point. Pass a cable tie (A) through the hole in the curtain metal support to secure the cables behind the curtain. The free length between the two cable ties (A and B) is approx. 60 cm (24 inch). Use some adhesive tape to secure the two cables together in this area. Do not use cable ties; they can catch on other items during movement. Pass a cable tie (A) through the hole in the curtain metal support to secure the cables behind the curtain. When installing the covers, place these cables inside the lower cover with the keypad cable. The cables must move freely; check that they cannot catch on anything. Correct cable routing around top right hand corner of Rotation board Page no. 1063 JC-TSG-A-016.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A016 - Rotation Movement Troubleshooting 3-4 Grease Checks 3-4-1 Position the arm for access • Lower the arm for good access to the rotation gears (1). • Switch OFF the Gantry electric power. 1 CAUTION The following procedures require power to be applied, in order to rotate the arm for access to the gears. After positioning the arm, be sure to switch off all power when you are inspecting or greasing the gears. 3-4-2 Inspect the gears • Locate the meshing teeth of the worm and worm gear (2), and the pair of spur gears (3). 2 3 Chapter 9 Page no. 1064 JC-TSG-A-016.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A016 - Rotation Movement Troubleshooting 3-4-3 Locate dry surfaces • Rotate the examination arm between -165° and +185°. Check for dry or partly dry surfaces as shown here (4); this is the visible effect of incorrect greasing 4 ! Notice: Be sure to identify dry or partly dry surfaces before greasing. General greasing may not help! The most critical areas are visible with the arm in the following positions: 0°, 45°, 135°, and 180°. Page no. 1065 JC-TSG-A-016.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A016 - Rotation Movement Troubleshooting 3-5 Grease Rotation Parts • Clean the Rotation parts with a Apply Loctite 7063 Super Cleaner (or equivalent, e.g. 3M Citrus Based Industrial Cleaner) and a cloth until all of the old grease is fully removed. • Rotate the arm between the limits of -165° and +185°, to as many positions as required to fully inspect and grease the gears. CAUTION After each movement, switch OFF power while inspecting and greasing. • Apply a light film of Grease (for Lift and Rotation) as required to the teeth of the worm gears and spur gears. • Do not apply excess grease: the quality of greasing is more important than the quantity. • Use a brush to apply grease: so as to avoid direct skin contact as far as possible. • Use a suitable cloth to remove excess grease. • Take care to ensure that you do not apply grease to the cog wheel of the Rotation Potentiometer. Grease on the cog wheel of the Rotation Potentiometer causes a bad connection, resulting in unexpected rotation errors. CAUTION Do not use any other type of grease, other than Grease for Lift and Rotation (5212483) (Orapi CT FLON 607). 5. Once you have finished applying grease to the all the Rotation parts, use the slow speed Arm Control buttons to rotate the Arm over the whole range two times in slow speed. 6. Use the fast speed Arm Control buttons to rotate the Arm over the whole range a few times in fast speed. 7. Check how grease has been spread to the Rotation parts. Examples of well spread grease, smoothly and uniformly along the whole radius of the Rotation gear, with no splattered grease are shown in illustration 4. Chapter 9 Page no. 1066 JC-TSG-A-016.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A016 - Rotation Movement Troubleshooting ILLUSTRATION 4 - EXAMPLES OF WELL APPLIED GREASE ON ROTATION PARTS If there are some areas where no grease exists, apply grease to these areas, rotate the Arm again in slow and fast speeds, and check the greasing again. 3-6 1. 2. 3. 4. Rotation Gas Spring Checks Ensure the Tube Head covers and Handle are installed on the Arm. Remove the Breast Support. Rotate the Arm to +90°. Use string to attach a 2 kg (11 lbs) weight to top of the handle, then use the slow speed Arm Control buttons to rotate the Arm back to 0° in slow speed. While moving the Arm back to 0°: a. Check on the Gantry LCD Display whether the following Rotation related errors appear: • 112/011 - Rotation control error • 112/012 - Rotation control error • 112/023 - Rotation control error b. Visually check that the speed of the rotation movement is constant. If there are no Rotation related errors/warnings and the movement is constant, the Rotation Gas Spring is in good condition, and you must continue with the troubleshooting tasks in illustration 1 If there are Rotation related errors/warnings and/or the movement is not constant, the Rotation Gas Spring needs changing according to Job Card D/R A230 - Rotation Gas Spring on page 1251. Page no. 1067 JC-TSG-A-016.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A016 - Rotation Movement Troubleshooting 3-7 Rotation Motor Checks Check cabling connections and connectors on the Rotation Board, and the Rotation Motor. • If the Rotation Motor connectors are not OK, change the Rotation Motor according to Job Card D/R A228 - Rotation Motor on page 1243. Note: To confirm whether the Rotation Motor is faulty you can additionally measure the resistance between the motor connector pins (J10 on the Rotation Board). If the resistance is infinite (open circuit), the Rotation Motor is faulty. • If the Rotation Board connectors are not OK, change the Rotation Board according to Job Card D/R A221 - Rotation Board on page 1223. • If the cabling connections and connectors are OK but the Rotation does not still work, change the Rotation Board according to Job Card D/R A221 - Rotation Board on page 1223, since it is the last remaining part that can be replaced. Chapter 9 Page no. 1068 JC-TSG-A-016.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A020 - Generator Power-Up Sequence Flow Charts Job Card TSG A020 - Generator Power-Up Sequence Flow Charts Chapter 9 1 INTRODUCTION This Job Card is intended as an aid to troubleshooting the Generator power-up problems. It must be used when the following errors are witnessed on the Senographe system, or when the Generator is having problems powering–up: • 071/082 Generator: timeout on signal Alim_Puis_OK (Inv_Supply_OK) (going ’low’ or ’high’) • 079/004 Exposure aborted: power fault The flow charts on the following pages suggest service actions (checks or corrective actions) to be taken in response to observed symptoms. In the flow charts below, the boards below have the following notation. Board Notation in charts Mains Distribution Board 200PL1 Supply Command Board 200PL2 Inverter Board 300PL1 Generator Command Board 400PL1 Generator Interface Board 400PL2 Generator CPU Board 400PL3 Gantry PDU Board PL101 Gantry Interface Board PL104 The order in which the actions are given is intended to optimize troubleshooting efficiency. This order takes into account the probability of possible causes, and the time and cost required for the suggested service actions. 2 TOOLS Multimeter Page no. 1069 JC-TSG-A-020.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A020 - Generator Power-Up Sequence Flow Charts 2-1 Troubleshooting Entry Note1: If cable 2109186 emergency safety loop is not connected to XJ10 on 200PL2 but instead cable from autotransformer is connected, autotransformer thermo switch 120°C can switch off the system in case of overload. See block diagram Generator power up sequence no. 1, then wait between 1 hour and 2 hours for the recovery console button "OFF" to be lit. Note2: If cable 2109186 emergency safety loop is not connected to XJ10 on 200PL2 but instead cable from autotransformer is connected, 200PL1 main distribution board TR2 thermo switch 120°C can switch off the system in case of overload. See block diagram Generator power up sequence no. 1, then wait 30 minutes for the recovery console button "OFF" to be lit. Power on Senographe system from console button. Failure: If the 200PL1 X1 relay does not engage, 200PL2 DE2 and 200PL1 DE5 both blink. Few milliseconds Failure: If K1 does not engage. 200PL1 relay X1 engages The Generator CPU board (400PL3) undertakes test. 3 seconds 400PL3 DS3 lights "CPU test OK". Main power contact K1 engages Detection of "Power_Supply_Present" Service terminal dialog enabled Autotest 0 : Detection of "INV_SUPPLY_OK" Check the X-ray Console ON button is functioning correctly. If the problem persists, check TP5 on 200PL2 is at 12 V when the X-ray Console ON button is pressed. If TP5 is at 12 V, check the thermal switch status on XJ10 200PL2. If TP5 is not at 12 V check, the LED status of DE4, DE5, DE6, and DE7 on 200PL1. If the problem persists, see Power-Up Sequence on page 1071 Failure: If K1 does not stay engaged see Power-Up Sequence on page 1071. Failure state present if "Power_Supply_Present" is not detected. In this case, the: • Console display is blank and beeps at 1 second intervals, and the button on console is lit • 200PL1 DE6 and 200PL2 DE1 are lit See Main Power Contact K1 Engaged but Console Beeps at 1 s Intervals on page 1079 to resolve. Probable cause is that 400PL2 board TP27 is stuck at "0", or that the 400PL3 board +5 V is out of tolarence. Other various system autotests Available for application mode Chapter 9 Failure state present if "INV_SUPPLY_OK" is not detected. In this case, the: • button on console is lit • Error message "E08 Generator: time out on signal INV_SUPPLY_OK (going "low" or "high") 071/082" on console display See E08: 071/082 Error on the Console Display on page 1081 to resolve. Page no. 1070 JC-TSG-A-020.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A020 - Generator Power-Up Sequence Flow Charts 2-2 Power-Up Sequence Start the power-up sequence "STOP" button on console lit? Yes 200PL1 DE5 and DE7 both lit? No No See Keep–Alive Voltage Checks on 200PL1 on page 1074. No Yes 200PL1 DE4, DE6, DE5, and DE7 all lit? Yes Start the power-up sequence by pressing button on console. button on console steadily lit and PL2 DE1 lit? button on console blinking? No Yes B A 200PL1 DE6, or DE5 only lit? No Yes Start the power-up sequence by pressing "ON" switch on 200PL1. 200PL2 DE1 lit? No Yes No 200PL2 voltage on PT2 at 12 V? No Check connector 400PL1 XJ8. Change X-ray Console. Yes No 200PL1resistor R5 OK? 200PL2 voltage on PT20 at 0 V? Yes No No Yes Change resistor R5. 200PL1: Resistor good continuity with associated circuit boards ? Yes 200PL2: Isolate the emergency off circuit by placing strap between PT0VV and PT1. No No Check cables connected to XJ8 and XJ9 on 200PL1. Change 200PL1. 200PL2 DE1lit? Power–up sequence started? Yes Problem with connector XJ1. Replace the cable connecting with 400PL1. Change 200PL2. Page no. 1071 JC-TSG-A-020.fm 200PL2 voltage on PT5 = 12 V? Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A020 - Generator Power-Up Sequence Flow Charts 2-3 Power-Up Sequence – A 200PL2 DE1 lit and main power contact K1 not engaged? A No 200PL1 DE4 lit? No Yes Yes Check the incoming mains voltage and re-configure the "SEL" wire on 200PL1. See Job Card PHY A016 - AC Connection on page 469. Change 200PL2. 200PL1 N1 and N2 lit? 200PL1: Check configuration of the IN1 voltage selection "STRAP" (see Job Card PHY A016 - AC Connection on page 469) and check tightness of TR1 primary lugs. No Yes Voltage across coil terminals of main power Yes contact K1 OK? No Change main power contact K1. Continuity between coil terminals of main power contact K1 and 200PL1 XJ10 connector OK? Yes No Yes Correct IN2 configuration (see Job Card PHY A016 - AC Connection on page 469) or re-tighten TR1 primary lugs. No Change cable bundle coming from 200PL2 XJ10. No Cable between 200PL1 XJ14 and 200PL2 XJ2 OK? No No 200PL1 connectors XJ1 and XJ3 tight? Re-tighten connectors XJ1 and/or XJ3. On 200PL2, strap PT17 to 0VV and observe if K1 activates. Main power contact K1 activated? IN2 configuration and TR1 primary lug tightness OK? Yes 200PL1: Problem with X1 relay. On 200PL2, strap PT13 to 0VV and observe if X1 activates. Yes Change 200PL2. Yes 200PL1 relay X1 activated? Change 200PL2. Yes Change 200PL1. Replace the cable between 200PL1 connector XJ14 and 200PL2 connector XJ2. No 200PL1: Strap 0VV to anode of D2 and observe whether X1 activates. No 200PL1 relay X1 activated? Change X1 relay. Yes Replace the cable between 200PL1 connector XJ14 and 200PL2 connector XJ2. Chapter 9 Page no. 1072 JC-TSG-A-020.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A020 - Generator Power-Up Sequence Flow Charts 2-4 Power-Up Sequence – B B 200PL2 DE1 and DE2 blinking with console button and 200PL1 DE1 lit? No Yes Recent repeated power–up attempts? No Yes Reset power–up sequence by opening Generator mains supply switch S1 ("0" position), then closing it again ("1" position). Normal power up sequence now possible using console button? No Yes End. 300PL1 600VF, 600VR, 0/600VF, 0/ 600VR connections tight? No Tighten appropriate connections. No Tighten appropriate connections. No Change capacitor bank. Yes 200PL1 lugs W1, W2, W3, and 300VR connections tight? Yes 300PL1: Voltage between 600VR and 0/600VR at approx. 600 V DC? Yes 200PL1: Voltage between PT13 and PT18 at approx. 3 V DC? Change 200PL1. No Yes Change 200PL2. Page no. 1073 JC-TSG-A-020.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A020 - Generator Power-Up Sequence Flow Charts 2-5 Keep–Alive Voltage Checks on 200PL1 Keep–alive voltage checks on 200PL1 Check that the Generator mains supply switch S1 is closed ("1" position) and that no attempt has been made to power on the Generator. 200PL1 DE9 lit? No Yes 200PL1: voltage between PT15 and No PT12 at 8 V? Yes 200PL1 DE3 Faulty. 200PL1 DE8 lit? Yes No 200PL1 DE2 lit? No Yes 200PL1: voltage between PT1 and PT2 at 12 V? Yes No 200PL1 DE8 lit? No Yes Yes No 200PL1 F3 OK? Yes 200PL1 DE8 Faulty. No 200PL1 DE3 lit? No Yes 200PL1: voltage between PT2 and PT3 at 12 V? Yes No 200PL1: voltage between PT12 and PT14 at – 8 V? No 200PL1 F3 OK? 200PL1 DE2 Faulty. Yes 200PL1 DE2 Faulty. Change 200PL1 F3. See Keep–Alive Voltage Checks on 200PL2 on page 200PL1 DE8 and DE9 lit? Yes Change 200PL1 F3. 200PL1 F1 OK? Change 200PL1 F3. 200PL1: Disconnect XJ15 No C 200PL1:Re-connect XJ15 No Yes 200PL1: Disconnect XJ14 200PL1: Disconnect XJ14 200PL1 DE3 and DE2 lit? No C See Keep–Alive Voltage Checks on 200PL2 on page Yes 200PL1 DE8 and DE9 lit? No Yes 200PL1:Re-connect XJ14 200PL2: Disconnect XJ2 200PL1 DE3 and DE2 lit? Yes No See Keep–Alive Voltage Checks on 200PL2 on page 1076. Chapter 9 No Cable bundle between (including connectors) 200PL1 XJ14 and 200PL2 XJ2 OK? Yes Change 200PL2. Replace the cable bundle between 200PL1 connector XJ14 and 200PL2 connector XJ2. No Cable bundle between (including connectors) 200PL1 XJ15 and 200PL2 XJ4 OK? Yes Change 200PL2. Replace the cable bundle between 200PL1 connector XJ15 and 200PL2 connector XJ4. Page no. 1074 JC-TSG-A-020.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A020 - Generator Power-Up Sequence Flow Charts 2-6 Keep–Alive Voltage Checks on 200PL1 - C C 200PL1: Is AC voltage between the IN2 voltage selection "strap" terminals 7 and 4 or 5 and 8 at mains voltage? No No 200PL1: Is AC voltage between Xj2 and XJ7 at mains voltage? Mains fuses F1/F2 all OK? Yes Voltage between Generator mains and supply switch S1 terminal at mains voltage? Yes Yes Change 200PL1. No See Partial Power– up Sequence on page 1077. No Yes No Replace appropriate wiring and/or appropriate fuse holder terminals. Yes No Replace appropriate wiring. With mains fuses F1 and F2 removed, is wiring continuity between mains fuse terminals F1–1/F2–1 and main power contact K1 terminals K1–1/K1–3 good? With mains fuses F1 and F2 removed, is wiring continuity between main power contact K1 terminals K1–2/K1–4 and 200PL1 XJ2/XJ7 good? Mains voltage present on input side of Gennerator mains supply switch S1? No Yes Replace Generator mains supply switch S1. Check incoming mains wiring. Yes Check (and replace where necessary) wiring between mains fuse holders (F1/F2) and Generator mains supply switch S1. Page no. 1075 JC-TSG-A-020.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A020 - Generator Power-Up Sequence Flow Charts 2-7 Keep–Alive Voltage Checks on 200PL2 Keep–alive voltage checks on 200PL2 No 200PL2: Voltage between "Plus VV" and 0VV at +12 V? Yes 200PL1: Voltage between +VE and 0VE at +8 V, and between –VE and 0VE at –8 V? Yes No No 200PL1: Voltage between TP17 and 0VE at +5 V? Yes Change 200PL1. Wiring between 200PL2 XJ2 and 200PL1 XJ14 OK? End of tests. Wiring between 200PL2 XJ4 and 200PL1 XJ15 OK? No Yes Yes Change 200PL2. Chapter 9 No Change 200PL2. Change wiring between 200PL2 XJ2 and 200PL1 XJ14. Change wiring between 200PL2 XJ4 and 200PL1 XJ15. Page no. 1076 JC-TSG-A-020.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A020 - Generator Power-Up Sequence Flow Charts 2-8 Partial Power–up Sequence Partial power–up sequence Open generator mains supply switch S1 ("0" position). On 200PL1, disconnect XJ4, XJ6, and XJ7. 200PL1: Configuration the of IN2 voltage selection "strap" correct? (see Job Card PHY A016 - AC Connection on page 469) No Correct 200PL1 IN2 configuration. (Job Card PHY A016 - AC Connection on page 469) Replace faulty mains fuses. Yes On 200PL1, unscrew and disconnect one end of R1 or R4. Measure values of R1 and R4. 200PL1 R1 and R4 values correct? No Replace 200PL1 R1 and/or R4 and faulty mains fuses F1/F2. Yes 200PL1: Connectivity between R1 and R4 and surrounding circuits OK? No Replace 200PL1 and faulty mains fuses F1/F2. Yes On 200PL1, check continuity between XJ7 and terminal 4 of relay X1, and between XJ3 and terminal 7 of relay X1. Continuity checks OK? No Yes On 200PL1,measure resistance between terminal 4 of relay X1, and 0 V. The resistance must be approximately equal to R1 and R4 in series if strap IN2 is in position "HT" or R1 and R4 in parallel if strap IN2 is in position "BT". See Job Card PHY A016 - AC Connection on page 469 and Job Card ELE A007 - Line Resistance Measurement on page 547. Resistance values OK? Replace 200PL1 and faulty mains fuses F1/F2. No Yes Replace 200PL1 R1 and/or R4 and faulty mains fuses F1/F2. Change faulty mains fuses F1/F2. D Page no. 1077 JC-TSG-A-020.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A020 - Generator Power-Up Sequence Flow Charts 2-9 Partial Power–up Sequence – D D Check following partial power–up sequence Close generator mains supply switch S1 ("1" position). 200PL1 DE5 and DE5 lit, and "STOP" button on console lit? No Start Power-up Sequence See Power-Up Sequence on page 1071 Yes Start the power-up sequence by pressing button on console. After 3 seconds 200PL1 DE5, DE2 and 200PL2 DE2 all lit? No Change 200PL1. Yes Open generator mains supply switch S1 ("0" position). On 200PL1, reconnect XJ4, XJ6, and XJ7. Close generator mains supply switch S1 ("1" position). Mains fuses F1/F2 all OK? No Replace 300PL1 and faulty mains fuses F1/F2. Yes Main power contact K1 activated? No Yes Start Power-up Sequence See Power-Up Sequence on page 1071 End of tests. Chapter 9 Page no. 1078 JC-TSG-A-020.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A020 - Generator Power-Up Sequence Flow Charts 2-10 Main Power Contact K1 Engaged but Console Beeps at 1 s Intervals 3 seconds after button on console is pressed, do the following conditions result: • Main power contact K1 engaged • Console display blank • button on console lit • 200PL1 DE6 and 200PL2 DE1 lit No Start Power-up Sequence See Power-Up Sequence on page 1071 Yes 400PL1 DS7, DS9, DS11, and 400PL2 DS1 thru DS9 all lit? No Check low voltage power supply 400T1. Yes 400PL2: voltage between TP27 and TP4 at 5 V? Yes Change 400PL2. (DR407 - page 1577) No 400PL1: voltage between TP2 and GND3 at 12 V? No Yes Continuity between 200PL1 XJ10 pin 19 and 400PL1 XJ2 pin 19 OK? No Change cable between 200PL1 XJ10 and 400PL1 XJ2. Yes Disconnect the cable between 200PL1 XJ10 and 400PL1 XJ2. 400PL1: voltage between TP82 and GND3 at 0 V? No Yes Reconnect cable between 200PL1 XJ10 and 400PL1 XJ2. Reconnect cable between 200PL1 XJ10 and 400PL1 XJ2. Change 400PL2. (DR407 - page 1577) E Page no. 1079 JC-TSG-A-020.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A020 - Generator Power-Up Sequence Flow Charts 2-11 Main Power Contact K1 Engaged but Console Beeps at 1 s Intervals – E E No 200PL2: voltage between TP4 and 0VV at 12 V? Yes Continuity between 200PL1 XJ1 pin 23 and 400PL1 XJ1 pin 23 OK? No Yes Change cable between 200PL1 XJ1 and 400PL1 XJ1. Change 400PL1. (DR406 - page 1569) Disconnect the cable from 200PL1 connector XJ11. Connect voltmeter between 200PL1 XJ11 pin 12 and 0VV. (Note: pin 1 is marked and at top left, pin 12 is bottom right). Measured voltage greater than 26 V? No Change 200PL1 and reconnect cable between 200PL1 XJ11 and 200PL2 XJ2. Yes Continuity OK in cable between 200PL1 XJ11 and 200PL2 XJ2? No Yes Change cable between 200PL1 XJ11 and 200PL2 XJ2. Change 200PL2 and reconnect cable between 200PL1 XJ11 and 200PL2 XJ2. Chapter 9 Page no. 1080 JC-TSG-A-020.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A020 - Generator Power-Up Sequence Flow Charts 2-12 E08: 071/082 Error on the Console Display Are the following conditions present: • button on console lit • Exposure disabled lamp on console lit • Error message "E08 Power supply failure 071/082" on console display No Start Power-up Sequence See Power-Up Sequence on page 1071 Yes 200PL1 DS5 and DS6 both lit? No Yes 400PL2: voltage between TP25 and TP4 at 5 V? No 200PL1: voltage between PT20 and 0VE less than 2 V? Yes Change 400PL2. (DR407 - page 1577 400PL1: voltage between TP85 and GNDB at 0 V? No Change 200PL2. Yes Check and correct position of "SEL" wire on 200PL1. See Job Card PHY A016 - AC Connection on page 469. "SEL" wire is set to a voltage greater than the true mains voltage. No Yes No 200PL2: voltage between TP4 and 0VV at 12 V? Continuity OK in cable between 400PL1 XJ10 and 400PL2 XJ2? Change cable between 400PL1 XJ10 and 400PL2 XJ2. Main power contact K1 terminal K1–14 at 12 V? Yes Yes Change 400PL2. (DR407 - page 1577 No No Continuity between 400PL1 connector XJ1 pin 25 and 200PL2 connector XJ1 pin 25 OK? Yes Change 400PL1. (DR406 - page 1569) No No Change cable between 400PL1 XJ1 and 200PL2 XJ1. Change cable between 200PL1 XJ11 and 200PL2 XJ2. No Change cable between 200PL1 XJ10 and main power contact K1. No Change main power contact K1. Yes Change 200PL2. Continuity between 200PL1 connector XJ11 pin 15 and 200PL2 connector XJ2 pin 15 OK? Yes Cable between 200PL1 XJ10 and main power contact K1 OK? Yes Main power contact K1 between K1–13 and K1–14 OK? Yes Change 200PL1. Page no. 1081 JC-TSG-A-020.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A020 - Generator Power-Up Sequence Flow Charts This page is blank. Chapter 9 Page no. 1082 JC-TSG-A-020.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A027 - 080/011 Error Trouble Shooting Job Card TSG A027 - 080/011 Error Trouble Shooting 1 Chapter 9 TOOLS None 2 ROOT CAUSE The error 080/011 only occurs during Generator Calibration when the X-ray Authorize signal from IDC is either: • dropped before the end of an exposure with an expected exposure time. In this case either the IDC Hardware/Software is faulty or the RT Cable from the IDC to the Generator is faulty. • dropped before the end of an exposure with an unexpectedly long exposure time due to the X-ray Tube arching. In this case either the tube simply needs warming up due to a long period of inactivity or is faulty. 3 RECOMMENDED ACTION 1. Try taking an exposure and listen on the Generator as to whether X-ray Tube arching is occurring. If during the exposure the high-tension noise from the Generator is not consistent and regularly changes, then X-ray Tube arching is occurring. 2. View the error logs. If 080/011 occurs in conjunction with E24 084/013 (RTL rises too late) or E24 079/014 (RTL drops too early), then either the IDC Hardware/Software is faulty or the RT Cable from the IDC to the Generator (via the Gantry XJ5 bulkhead connection) is faulty. Contact your OLC for further trouble-shooting advice. If 080/011 occurs during Generator Calibration, then the X-ray Tube is arching. Proceed as follows: a. Perform Job Card CAL A007 - Automatic X-ray Tube Warm-Up on page 1661. b. Take some exposures and listen on the Generator as to whether X-ray Tube arching is still occurring. c. If error 080/011 persists, perform Job Card CAL A003 - X-Ray Tube Focal Bias Voltage Scale Factor on page 1655. d. If error 080/011 persists, change the X-Ray Tube according to Job Card D/R A261 - X-ray Tube Assembly on page 1353. Page no. 1083 JC-TSG-A-027.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG A027 - 080/011 Error Trouble Shooting This page is blank. Chapter 9 Page no. 1084 JC-TSG-A-027.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG M028 - E24 084/008 Error Troubleshooting Job Card TSG M028 - E24 084/008 Error Troubleshooting 1 Chapter 9 INTRODUCTION This Job Card is intended as an aid to troubleshooting for intermittent abort at pre-exposure with error E24 084/008. A console reboot is required for system recovery. 2 TOOLS NA 3 ROOT CAUSES The two possible error causes are the following: 3-1 Arm Synchronization Error at AOP Pre-Exposure Start or Manual Exposure Start This error is due to a positioner failure (e.g. Bucky). In this case, an additional error code is logged from the positioner in the same timestamp range as the E24 084/008 error. Troubleshooting must be performed from this specific positioner error code. 3-2 Tube Arcing during AOP Pre-Exposure When a tube arcing occurs during an AOP pre-exposure, the acquisition has to be aborted for AOP performance. But the pre-exposure tube spit abort creates an E24 084/008 arm synchronization error instead of reporting an acquisition abort (S01). As a result, the operator has to power OFF then ON from the X-ray console for the system to recover. ! Notice: Today, there is no short-term solution to totally get rid of the E24 084/008 error resulting from tube arcing (a system redesign is needed). Tube arcing is a normal behavior all along tube life. As a result, if the E24 084/008 error occurs less than once every 400 exams, it is not required to change the tube. 4 RECOMMENDED ACTION Perform the troubleshooting actions as presented in Illustration 1, E24 Failure before Exposure 084/008 Troubleshooting on page 1086. Page no. 1085 JC-TSG-M-028.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG M028 - E24 084/008 Error Troubleshooting ILLUSTRATION 1 - E24 FAILURE BEFORE EXPOSURE 084/008 TROUBLESHOOTING Intermittent E24 084/008 Do not know At AOP preexposure Yes No X-Ray started (X-Ray end: beep heard)? mAs value displayed Do not know Check error log No Yes POS 170/007 Bucky init error or DMR 027/003 at +/- 2s? Yes You may confirm that you have the “tube arcing” issue by checking the tube spit number Only with Bucky? No Yes No Pre-exposure stopped by tube arcing 1. Perform Job Card TSG M022 - HV Troubleshooting on page 1403. 2. See section 5, Preventive Actions that May Reduce Tube Arcing on page 1087. .3. Write down the current acquisition number (See section 6-2, Acquisition Counter on page 1089). Bucky to Main Pos CPU Synchronization Error Check/Replace Positioner CAN bus 1 W311 Distribution Board PL301 J3a to Bucky Board PL302 J1A 2 W314 Distribution Board PL301 J1 - to Interf. Board PL104 J5 System Observation: Observe system during at least one month (See section 6, System Observation on page 1088). A POS to DMR Synchronization Error 1. Check/Replace optical fiber between Generator and Gantry W121 PL104-J8 to 400PL2-XJ9 2. Check/Replace Gantry interface board PL104 3. Check/Replace Generator interface board 400PL2 Chapter 9 Solve the issue? Could be B before A if you can check another Bucky. No Change Bucky (see Job Card D/R A255 Bucky on page 1339) B Page no. 1086 JC-TSG-M-028.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG M028 - E24 084/008 Error Troubleshooting 5 PREVENTIVE ACTIONS THAT MAY REDUCE TUBE ARCING During tube lifecycle, it is normal to observe tube arcing, which generates exposure spit/interruption. Note: Do not plan to replace the tube if tube arcing occurrence is low (1 tube arcing every 400 exams). Nevertheless, it is recommended to perform the calibrations below. Tube arcing may: • Occur more frequently for brand new and old tubes • Increase with tube usage as a result of wrong or inaccurate generator calibrations. It may be possible that Job Card TSG M022 - HV Troubleshooting on page 1403 does not report any corrective action. Intermittent arcing failure may result from a calibration or a heater current that is not adjusted to the current tube state. For information on heater current regulation, see section 7, DMR Heater Current Management on page 1090. Since tube usage may change the tube characteristics, it may be useful to perform all the calibrations that are required at tube change. See the Completion section of Job Card D/R A261 - X-ray Tube Assembly on page 1353. Perform the following calibrations: Calibrations - Checks Job Card Acquisition Image Chain Bias Calibration Job Card CAL A003 - X-Ray Tube Focal Bias Voltage Scale Factor on page 1655 Heating Current Calibration Job Card CAL A001 - Heater Current Scale Factor on page 1649 mAs X-ray Calibration Job Card CAL A012 - X-Ray Tube Heater Current on page 1673 Tube Tilt Calibration Job Card CAL A027 - Tube Tilt Calibration on page 1681 Collimator Calibration Job Card CAL A029 - Collimator Format Calibration on page 1683 Collimation Check Job Card ELE A028 - Collimation Checks on page 679 If Collimation Check not OK, repeat Collimator Calibration Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 If IQ Tests not OK, repeat all calibrations from Bad Pixel. Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Use the same dosimeter as that used for CAL A046 AOP: Automatic Optimization of Parameters AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations from AOP Calibration Considering that tube arcing may result from a tube instability regarding its heater state, if the generator/ tube calibration doesn't reduce the tube arcing occurrence, you may ask the operator to perform the heating procedure for the selected focal spot size (large or small) when the system has not been used Page no. 1087 JC-TSG-M-028.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG M028 - E24 084/008 Error Troubleshooting for more than 0.5 day. To perform the desired heating procedure, proceed as follows: • Heating procedure for Large focal spot, in contact mode (bucky or stereotactic positioner) 1. Lock Bucky. 2. Put a flat field phantom on Bucky. 3. Acquire two images using the following configuration: Track Mo, 22 kV and 225 mAs 4. Acquire two images using the following configuration: Track Rh, 27 kV and 180 mAs • Heating procedure for Small focal spot, in magnification mode 1. Lock Magstand. 2. Put a flat field phantom on Magstand. 3. Acquire two images using the following configuration: Track Mo, 22 kV and 110 mAs 4. Acquire two images using the following configuration: Track Rh, 29 kV and 110 mAs 6 SYSTEM OBSERVATION The purpose of site observation is to determine the occurrence of the E24 008/084 error resulting from tube arcing, before deciding whether or not to change the tube. 6-1 Procedure The below procedure is a suggested site analysis procedure. You may use another site analysis procedure that will give you the same result. 1. Write down: • The current acquisition number value N1 (See section 6-2, Acquisition Counter on page 1089) after performing Job Card TSG M022 - HV Troubleshooting on page 1403 or the preventive calibrations listed in section 5, Preventive Actions that May Reduce Tube Arcing on page 1087 • The current date of intervention D1. 2. Write down the new acquisition number value N2 and the new date of intervention D2. 3. Compute the number of acquisitions since your previous date of intervention (N = N2 - N1). 4. Compute the number of exams since your previous intervention since date of intervention D1 [Number of Exams] = N/4 (considering that four views are performed per exam). 5. Compute the number of accepted E24 084/008 errors resulting from tube arcing (one every 400 exams): [Accepted Occurrence] = [Number of Exams]/400. 6. Check the number of E24 084/008 errors resulting from tube arcing (no 170/007 and no 027/003 logged at the same time): [Number of E24 arcing] during time period [D1,D2]. Chapter 9 Page no. 1088 JC-TSG-M-028.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG M028 - E24 084/008 Error Troubleshooting 7. Analyze the result: • If [Number of E24 arcing] is smaller than or equals [Accepted Occurrence Number], you shall not change the tube. • If [Number of E24 arcing] is greater than [Accepted Occurrence Number], you may plan on changing the tube. 6-2 Acquisition Counter To display the current acquisition number, you must press the SETUP button. The current acquisition number appears in the upper right corner of the DMR menu window below (e.g 2.650E+2, as shown in the illustration below). Page no. 1089 JC-TSG-M-028.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG M028 - E24 084/008 Error Troubleshooting 7 DMR HEATER CURRENT MANAGEMENT 7-1 Reading Tube Spit Number To read the tube arcing number stored in the DMR, connect the Mammocom tool (see Section "Mammocom - How to..." in the SIP-M and go to the following menus as described in the following Illustration. Turn off Senographe DMR Connect service terminal Board - Generator Interface 400PL2 XJ4 Turn on Senographe DMR and service terminal Load communication software Select Terminal Emulator Press F10 on service terminal 004 Application mode now available from service terminal Press on F9 on service terminal Select arm/gene install GENE MEDICAL LANGUAGE ARM 001 GEMS-E (gen soft version) GEN (release date) INSTALL MAINT 272 MAINTENANCE MENU STAT PROD MAINT 273 LAST ACCESS TO STATS (date) (time) STATS 276 STATISTICS MENU SHOW TRANS CLEAR 277 STAT. INTERACTIVE MODE KV/MAS TABLE GENER CONFI DATE This menu provides the general counters: exposure counters by exposure mode and, at the bottom, the tube arcing number. 7-2 • • • Information on the DMR heater current behavior The DMR regulates the tube heater current all along the day, based on the last heater current applied during exposure for the given Focal Spot/Track/kV triplet. Then, the DMR continuously refreshes heater current for a given triplet. If you make an exposure using a cold tube (could be in the morning), you set the heater current for a cold tube for the selected triplet that may not be suitable for a hot tube. As a result, in order to reach the expected mA value, the DMR sets up the heater current faster, which may cause tube arcing for an aged tube. Chapter 9 Page no. 1090 JC-TSG-M-028.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card TSG M028 - E24 084/008 Error Troubleshooting 7-3 Supported Pre-Exposure Configurations The AOP pre-exposure mAs value is equal to 4mAs. The AOP pre-exposure focal spot triplets are as follows: Large focal spot Small focal spot Track kV Track kV Mo 22 Mo 22 Mo 23 Mo 23 Mo 24 Mo 24 Mo 25 Mo 27 Rh 27 Mo 27 Rh 28 Mo 30 Rh 31 Rh 29 Rh 32 Rh 31 Rh 34 Rh 34 Page no. 1091 JC-TSG-M-028.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card TSG M028 - E24 084/008 Error Troubleshooting This page is blank. Chapter 9 Page no. 1092 JC-TSG-M-028.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Disassembly/Reassembly DISASSEMBLY/REASSEMBLY CHAPTER 9 Disassembly/Reassembly information is given in the following modules: - Job Card D/R A121 - Optical Fiber (Gantry to Generator) on page 1097 - Job Card D/R A141 - Image Receptor/Digital Detector on page 1099 - Job Card D/R A142 - Detector Power Supply on page 1107 - Job Card D/R A150 - System Fuses on page 1109 - Job Card D/R A189 - Interface Board on page 1125 - Job Card D/R A190 - Gantry CPU Board on page 1131 - Job Card D/R A191 - PDU Board on page 1137 - Job Card D/R A192 - Arm Distribution Board on page 1143 - Job Card D/R A193 - AC/DC Board on page 1147 - Job Card D/R A194 - AC/DC Module on page 1153 - Job Card D/R A201 - Lift Board on page 1161 - Job Card D/R A202 - Upper Optical Fork on page 1167 - Job Card D/R A203 - Lower Optical Fork on page 1171 - Job Card D/R A204 - Lift Potentiometer on page 1175 - Job Card D/R A205 - Lift Motor on page 1179 - Job Card D/R A206A - Lift Gas Spring on page 1183 - Job Card D/R A207 - Lift Belt on page 1189 - Job Card D/R A208 - Gantry Curtains on page 1193 - Job Card D/R A210 - Gantry cover replacement guide on page 1197 - Job Card D/R A212 - Gantry Readout on page 1215 - Job Card D/R A215 - Arm Control Keypad Cables on page 1217 - Job Card D/R A216 - Arm Control Keypads on page 1219 - Job Card D/R A221 - Rotation Board on page 1223 - Job Card D/R A222 - Clutch and Cable on page 1227 - Job Card D/R A223 - Rotation Optical Fork on page 1231 - Job Card D/R A224 - Gas Spring for Rotation Worm Gear on page 1235 - Job Card D/R A227 - Rotation Potentiometer on page 1239 - Job Card D/R A228 - Rotation Motor on page 1243 - Job Card D/R A229 - Rotation Brake on page 1247 - Job Card D/R A230 - Rotation Gas Spring on page 1251 - Job Card D/R A232 - Lift Screw Assembly on page 1255 - Job Card D/R A233 - Lift Screw Assembly Top Brake on page 1279 - Job Card D/R A243 - Compression Potentiometer and Cable on page 1289 - Job Card D/R A244 - Compression Motor with Encoder and Compression Belt on page 1297 - Job Card D/R A245 - Manual Compression Belt on page 1299 - Job Card D/R A246 - Manual Compression Brake on page 1301 - Job Card D/R A247 - Motorized Compression Brake on page 1309 - Job Card D/R A248 - Force Sensor on page 1313 - Job Card D/R A249 - W304 Cable for Paddle Recognition on page 1319 Page no. 1093 DR.FM Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Disassembly/Reassembly - Job Card D/R A250 - Compression Board on page 1323 Job Card D/R A251 - Paddle Holder Board on page 1331 Job card D/R A252 - Compression Trolley Kit on page 1337 Job Card D/R A255 - Bucky on page 1339 Job card D/R A256 - Bucky Top Cover on page 1343 Job card D/R A258 - Bucky Board on page 1347 Job Card D/R A261 - X-ray Tube Assembly on page 1353 Job Card D/R A264 - Tilt Sensor on page 1357 Job Card D/R A265 - Tilt Motor and Drive Assembly on page 1361 Job Card D/R A266 - Tube Tilt Board on page 1365 Job Card D/R A280 - Collimator Set on page 1369 Job Card D/R A285 - Collimator Filter Wheel Assembly on page 1375 Job Card D/R A287 - Collimator DC-DC Board on page 1379 Job Card D/R A288 - Collimator Lamp on page 1383 Job Card D/R A290 - FOV Button on page 1391 Job Card D/R A291 - Stop Button on page 1395 Job Card D/R A292 - Tube Tilt Pivots on page 1397 Job Card D/R A311 - AWS Unit on page 1401 Job Card D/R A312 - Mouse on page 1417 Job Card D/R A313 - Trackball on page 1427 Job Card D/R A315 - International Keyboard on page 1443 Job Card D/R A317 - Radiation Screen on page 1463 Job Card D/R A318 - LCD Monitor on page 1469 Job Card D/R A319 - Rotative Arm on page 1483 Job Card D/R A321 - IDC Computer on page 1503 Job Card D/R A322 - RJ-45 Service Network Patch Panel on page 1517 Job Card D/R A331 - UPS on page 1521 Job Card D/R A332 - UPS Battery Replacement on page 1529 Job Card D/R A335 - AWS (U20) Motherboard Battery (V3 Control Stations only) on page 1537 Job Card D/R A401 - Generator CPU Board 400PL3 on page 1543 Job Card D/R A402 - Generator CPU Battery on page 1549 Job Card D/R A403 - Capacitor Box on page 1553 Job Card D/R A404 - HV Unit on page 1559 Job Card D/R A405 - HV Cable on page 1565 Job Card D/R A406 - Generator Command Board 400-PL1 on page 1569 Job Card D/R A407 - Generator Interface Board 400-PL2 on page 1577 Job Card D/R A408 - Generator Supply Command Board 200-PL2 on page 1583 Job Card D/R A409 - Relay Board 200-PL4 on page 1591 Job Card D/R A410 - Inverter Board 300-PL1 on page 1595 Job Card D/R A411 - Mains Distribution Board 200-PL1 on page 1601 Job Card D/R A412 - Anode Starter Board 300-PL2 on page 1609 Job Card D/R A413 - BT Power Supply 400-T1 on page 1613 Chapter 9 Page no. 1094 DR.FM GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Disassembly/Reassembly - Job Card D/R A414 - Power Line Filter Box on page 1617 Job Card D/R A415 - Generator Board CPU EEPROMs on page 1625 Job Card D/R A421 - Conditioner Unit on page 1633 Page no. 1095 DR.FM Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Disassembly/Reassembly This page is blank. Chapter 9 Page no. 1096 DR.FM GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A121 - Optical Fiber (Gantry to Generator) Job Card D/R A121 - Optical Fiber (Gantry to Generator) 1 • • Chapter 9 SUPPLIES Optical fibers (W119 and W120) Cable ties 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 60 minutes 4 SAFETY PRECAUTIONS No specific safety precautions are applicable. 5 PREREQUISITES None 6 PROCEDURE CAUTION When disconnecting optical fibers, always pull on the connector and not on the cable. If in doubt, check that the core of the fiber is flush with the end of the connector. 6-1 Removal and Reinstallation of Optical Fibers 1. Switch off the Senographe electrical power. 2. Remove the generator covers and the Gantry column covers (see Job Card PHY A042 - Remove/ Reinstall Generator Covers on page 513 and Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). 3. Disconnect the optical fibers at both ends. 4. Disengage the harness connecting the generator and the Gantry, particularly if the harness is coiled under the generator. 5. Open the harness protection housing. 6. Disengage the black ribbed outer cover protecting the optical fibers. Note: It is necessary to cut some of the cable ties in the Generator and the Gantry. 7. Remove the harness clamp at the bottom of the Gantry column. 8. Gently pull the black ribbed outer cover out of the generator and the Gantry. CAUTION Take care to avoid rubbing or dirt on the ends of the "good" fibers. 9. Open the ribbed outer cover, over its entire length, and remove the defective fiber. Page no. 1097 JC-DR-A-121.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A121 - Optical Fiber (Gantry to Generator) 10. Replace this fiber, respecting connector color coding. 11. Temporarily reconnect the four fibers to the generator and Gantry, and check that the system operates correctly when the electrical power is switched on. 12. Disconnect the four fibers and reinstall the ribbed outer cover in the harness. 13. Carefully install new cable ties, particularly inside the Gantry and between the base plate and Gantry interface board PL104. 6-2 Functional Check 1. Switch on the Senographe electrical power. 2. Raise and lower the column and visually check that the movement is not fouling any of the cables. 3. Reinstall the generator covers and the Gantry column covers. 7 COMPLETION None Chapter 9 Page no. 1098 JC-DR-A-121.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A141 - Image Receptor/Digital Detector Job Card D/R A141 - Image Receptor/Digital Detector 1 Chapter 9 SUPPLIES Digital Detector and its floppy disk / CD-ROM with parameters. Order the digital detector according to your system configuration and country as summarized in the table below. TABLE 1 - DETECTOR FRU ORDERING INFORMATION System Version Country FRU New system with a Failure On Installation (FOI). All countries 2383172-5 All existing systems in the field that have received FMI12075DS or have ADS version 32.05 or later (manufactured from July 2006). Iberia Region 2383172-5 All countries other than Iberia Region 2383172-4 All countries 2383172-3 All existing systems in the field that have ADS version 32.04 or earlier (manufactured before July 2006), and that did not receive FMI12075DS. Note: If 2383172-3 is no longer available, then apply FMI12075DS and order the FRU corresponding to the country in which the system is located. FOI=Failure on Installation ! Notice: When investigating a Detector problem, never attempt to open a defective Detector and never attempt to remove the Detector carbon top cover. If you open a defective Detector or remove the Detector carbon top cover, the Detector warranty is void and the repair center will not take the responsibility to repair the Detector. 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 2 Field Engineers Time: 45 minutes 4 SAFETY PRECAUTIONS WARNING - Power off the Gantry before disconnecting or working on the Digital Detector. - If the casing is punctured, wear protective gloves and dust masks when removing the detector. Send the protective items for disposal along with the defective detector. - The Digital Detector is cumbersome. Two people are required for its removal and installation (see section 6-1, page 1101). Follow standard safety practices for handling large components. Page no. 1099 JC-DR-A-141.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A141 - Image Receptor/Digital Detector 5 PREREQUISITES WARNING • • • • • Before installing the new detector, you must leave it packed for at least one day so that it does not suffer from condensation. Pull out the Bucky and remove it from the Detector.Switch off the Gantry power. Remove the Arm and Detector covers (see Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). Switch on the Gantry power. Set the arm to an intermediate height. Rotate the arm to between a working position of –45° to + 45°. ! Notice: Never rotate the arm outside of the range –45° to + 45° when installing the Digital Detector. If the coolant pipes are not secured properly and if this arm angle range is not respected, there is a risk of coolant entering the inner workings of the Digital Detector. • Switch off the Gantry power. • Remove the Arm covers (Refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). • Remove the Generator covers (Refer to Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513). • Switch off the Conditioner. Chapter 9 Page no. 1100 JC-DR-A-141.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A141 - Image Receptor/Digital Detector 6 PROCEDURE 6-1 Disassembly of the Digital Detector 1. Release (two screws) and remove the front connector (1) (screwdriver). 2. Disconnect the optical fiber cables (2) by extracting the optical connectors by hand. 3 2 CAUTION Do not apply force to fiber cables, and take care not to bend them excessively. 3. Be sure that at least one of the two coolant pipes has a distinctive mark (you will have to reconnect them to the appropriate connectors); then disconnect the coolant supply pipes (3) by pulling on the connectors (not the pipes). 4 1 CAUTION Be careful to avoid spillage of coolant, especially onto or near electrical connections. If any coolant is spilled, it must be cleaned up immediately. 4. Release the screws (4) securing the ground cables (7 mm open ended wrench). 5. Remove the three screws (5) securing the Bucky interconnection plate (6) to the rear wall plate (7) of the Detector support (3 mm allen wrench). 5 6 7 6. Release the hex screw (8) securing the ground cable terminal (4 mm allen wrench). 8 CAUTION Two people are required for removal and subsequent reinstallation of the Digital Detector. At least two of the detector securing screws must be correctly fitted when the detector is not supported by hand or a suitable stand. Page no. 1101 JC-DR-A-141.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A141 - Image Receptor/Digital Detector Never allow the mass of the detector to fall onto its alignment pins while the securing screws are not fitted. 7. Remove the lower two of the four Detector securing screws (9) (5 mm allen wrench). 8. While one person holds the detector against its alignment pins on 9 the interface plate, the other removes the two upper securing screws (9) to hold it in position (5 mm allen wrench). 9. Remove the detector by pulling it backwards from its guides. 10. Place the defective Detector on a stable stand. WARNING Drain all coolant from the detector before it is stored or shipped. Shipping a detector which contains coolant may cause irreparable damage. This is especially important in winter, when there is a danger of freezing. WARNING Note: The removed Digital Detector must be packed in the appropriate engineering-designed shipping crate. Digital Detectors that are not correctly packed and shipped have to be replaced at a high cost for the company. 6-2 Reassembly of the Digital Detector 1. To reinstall the Digital Detector, follow the procedure given in section 6-2 of Installation of Digital Detector on page 782. 2. To align the Bucky correctly on the new Digital Detector, refer to section 6-2 of Job Card D/R A255 Bucky on page 1339. 6-3 Top Up with Conditioner Fluid Check the conditioner fluid level and top up as necessary. • Proceed as follows CAUTION When performing any of the following procedures, be careful to avoid spillage of coolant, especially onto or near electrical connections. If any coolant is spilled, it must be cleaned up immediately. Chapter 9 Page no. 1102 JC-DR-A-141.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A141 - Image Receptor/Digital Detector Note: A document describing an alternate procedure is provided in the coolant kit. For maximum safety and minimum risk of spillage, GEMS recommend using the procedure given below: 1. When adding coolant, use the container labeled Topping. 2. Remove the reservoir cap and check the liquid level. 3. If necessary, add liquid until it reaches the bottom of the cap threads. 4. To flush air from the circuit; proceed as follows: - Switch on the unit (switch on the Main Distribution Rack circuit breaker and press the Conditioner on button in the Generator cabinet). - As the coolant circulates and air bubbles are flushed from the coolant circuit, the coolant level falls. Add liquid as necessary until the level is steady at the bottom of the cap threads. 5. Replace the reservoir cap when you are satisfied that the level is correct. 6. Replace the Generator covers (Refer to Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513). 6-4 Load Detector Parameters The procedure to load the detector parameters varies according to type of Control Station in the system. Note: BEFORE Loading Detector Parameters, clear all detector calibrations (select Service Desktop/ Calibration/Detector; then select Clear Calibrations and perform the Load Detector Parameters procedure as indicated). 6-4-1 Load Detector Parameters on V1/V2 Control Stations 1. Launch the Service Desktop (see Launching the Service Desktop on page 120). 2. From Service Desktop, click the Utilities button . 3. Under Workstation Tools, click DETECTOR REPLACEMENT. 4. Insert the Mammo Detector Manufacturing Data floppy diskette into the floppy drive on the AWS unit (not the IDC). 5. Click the START button to start the digital detector firmware update process. The Results section of the Service Desktop updates with a Processing progress bar while the firmware is being written to the digital detector. Once the firmware is written to the digital detector the Results section of the Service Desktop updates with the message DETECTOR REPLACEMENT COMPLETE. 6. 7. Remove the floppy diskette from the floppy drive on the AWS unit. 8. Reboot the Senographe system. 9. View the Service Desktop home page (see Launching the Service Desktop on page 120). Check that the value of the DETECTOR_ID on the Service Desktop home page corresponds to the value written on the LFOV1 Mammo Detector Manufacturing Data floppy disk. The DETECTOR_ID value is of the format LLnnn_nn (e.g. FL002_01). 6-4-2 Load Detector Parameters on V3/V4 Control Stations 1. Launch the Service Desktop (see Launching the Service Desktop on page 120). 2. From Service Desktop, click the Utilities button . 3. Under Workstation Tools, click DETECTOR REPLACEMENT. Page no. 1103 JC-DR-A-141.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A141 - Image Receptor/Digital Detector 4. Insert the SFOV Mammo Detector Manufacturing Data CD-ROM into the CD-ROM drive of the AWS unit. 5. Click the START button to start the digital detector firmware update process. The Results section of the Service Desktop updates with a Processing progress bar while the firmware is being written to the digital detector. Once the firmware is written to the digital detector the Results section of the Service Desktop updates with the message DETECTOR REPLACEMENT COMPLETE, and the AWS unit automatically ejects the CD-ROM drive. 6. Remove the SFOV Mammo Detector Manufacturing Data CD-ROM from the CD-ROM drive of the AWS unit, and close the CD-ROM drive. 7. Reboot the Senographe system. 8. View the Service Desktop home page (see Launching the Service Desktop on page 120). Check that the value of the DETECTOR_ID on the Service Desktop home page corresponds to the value written on the SFOV Mammo Detector Manufacturing Data CD-ROM. The DETECTOR_ID value is of the format LLnnn_nn (e.g. FL002_01). Chapter 9 Page no. 1104 JC-DR-A-141.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A141 - Image Receptor/Digital Detector 6-5 First power-on Check 1. Cycle OFF/ON the system. 2. Check that the message All devices are ready appears on the screen. If yes proceed to section 7 below. 3. If error messages appear on screen, verify that the various connections are correctly made and refer to Job Card TSG A007 - Digital Detector Firmware Corrupted on page 1015 then proceed to section 7 below. 7 COMPLETION 7-1 Calibrations to Carry Out Carry out the following calibrations: Calibrations - Checks Job Card Acquisition Image Chain Tube Tilt Calibration Job Card CAL A027 - Tube Tilt Calibration on page 1681 Collimator Calibration Job Card CAL A029 - Collimator Format Calibration on page 1683 Collimation Check Job Card ELE A028 - Collimation Checks on page 679 If Collimation Check not OK, repeat Collimator Calibration Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 If IQ Tests not OK, repeat all calibrations from Bad Pixel. Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Use the same dosimeter as that used for Half-Value Layer Measurement. If in doubt, repeat Job Card CAL A046 - Half-Value Layer Measurement on page 1703. AOP: Automatic Optimization of Parameters AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations from AOP Calibration 7-2 If Stereotaxy Option Present If the system has the Stereotaxy option, you must perform the required, applicable checks and calibrations listed in section 7-1, Calibrations to Carry Out on page 1105 and the following Stereotaxy tasks: • JC-CAL-A002 - Image Plane to Carbon Cover Distance in the Stereotaxy Service Manual (only for ADS 53.40). • Vertical approach (QC Test 2) and lateral approach (QC Test 5) accuracy checks described in the "Planned Maintenance" section of the Stereotaxy Operator Manual. You must ask the Operator to perform: • The necessary biopsy device accuracy checks as described in QC Test 3 and QC Test 4 of the "Planned Maintenance" section of the Stereotaxy Operator Manual. • The puncture tool accuracy check as described in QC Test 6 of the "Planned Maintenance" section of the Stereotaxy Operator Manual. Page no. 1105 JC-DR-A-141.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A141 - Image Receptor/Digital Detector 7-3 Data Backup After performing the specified calibration and check procedures, a system backup must be made to safeguard the new detector and calibration data.Follow the instructions given in Job Card ELE A052 - Backup/Restore Procedure on page 771. 7-4 CAD License If the CAD option is present, the new Detector ID must be declared in the CAD computer. Follow the instructions given in the CAD Unit Service Manual. Chapter 9 Page no. 1106 JC-DR-A-141.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A142 - Detector Power Supply Job Card D/R A142 - Detector Power Supply 1 Chapter 9 SUPPLIES Detector Power Supply 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 15 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 • • PREREQUISITE Turn the Gantry power off. Remove the Gantry column covers. See Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. Page no. 1107 JC-DR-A-142.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A142 - Detector Power Supply 6 PROCEDURE 6-1 Disassembly of Power Supply 1 1. Switch off the Gantry. 2. Locate the defective power supply (6) mounted on the back of the Senographe column. 3. Disconnect the AC mains connector (3) and the two low voltage connectors (1) (one to Image Receptor and one to IDC). 4. Release without removing the two securing nuts (4, 5) located at bottom of power supply chassis (5.5 mm open-ended wrench) (nuts not seen on this picture). 5. Remove the two securing nuts (2, 7) securing the top of the power supply chassis (5.5 mm open-ended wrench). Take care not to lose the nuts. 6. Remove the defective power supply by holding both the top and bottom of its chassis with both hands. 6 3 Note: Tilt the power supply assembly slightly forward to ease removal. 5 4 6-2 2 7 Reassembly Reverse the disassembly procedure. 6-3 Functional Check 1. Switch on the Senographe electrical power. 2. Check that the normal boot message is shown. 3. Make a test exposure. 7 COMPLETION None Chapter 9 Page no. 1108 JC-DR-A-142.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A150 - System Fuses Job Card D/R A150 - System Fuses 1 Chapter 9 SUPPLIES Fuses, according to the table below: Sub-system location Board/Location (illustration ref.) Fuse Specification Fuse Part Number Generator (Conditioner cabinet part) Mains Distribution Assembly - F1 (illustration 1) 250 Vac, 10 A, Delay 99183979 Generator Gantry Mains Distribution Assembly - F2 (illustration 1) 250 Vac, 5 A, Delay 99183923 Mains Distribution Assembly - F3 (illustration 1) 250 Vac, 1.6 A, Delay 99183925 Mains Distribution Assembly - F4 (illustration 1) 250 Vac, 5 A, Delay 99183923 Generator Command Board - F1 (illustration 2) 250 Vac, 2.5 A, Delay 99194291 Generator Command Board - F2 (illustration 2) 250 Vac, 2.5 A, Delay 99194291 Generator Command Board - F3 (illustration 2) 250 Vac, 2.5 A, Delay 99194291 Supply Command Board - F1 (illustration 3) 250 Vac, 3.15 A, Delay 99194288 Supply Command Board - F2 (illustration 3) 250 Vac, 0.5 A, Delay 58079685 Supply Command Board - F3 (illustration 3) 150 Vac, 125 A, Fast 91684676 Supply Command Board - F4 (illustration 3) 380 Vac, 10 A, Fast 58079166 Supply Command Board - F5 (illustration 3) 380 Vac, 10 A, Fast 58079166 Supply Command Board - F6 (illustration 3) 250 Vac, 16 A, Fast 58079690 Next to circuit breaker - F1 (illustration 4) 600 Vac, 35 A, Fast 99184154 Next to circuit breaker - F2 (illustration 4) 600 Vac, 35 A, Fast 99184154 Mains Distribution Board - F1 (illustration 5) 250 Vac, 1 A, Delay 58079686 Mains Distribution Board - F2 (illustration 5) 250 Vac, 0.5 A, Delay 58079685 Mains Distribution Board - F3 (illustration 5) 250 Vac, 0.5 A, Delay 58079685 PDU Board - F1 (illustration 6) 250 Vac, 6.25 A, Delay 46-170021P60 PDU Board - F3 (illustration 6) 250 Vac, 0.5A, Delay 46-170021P31 PDU Board - F4 (illustration 6) 250 Vac, 2A, Delay 46-170021P30 PDU Board - F5 (see note) (illustration 6) 250 Vac, 125 mA, Delay 5344386-2 PDU Board - F6 (see note) (illustration 6) 250 Vac, 125 mA, Delay 5344386-2 MPCB - F1 (illustration 6) 600 Vac, 20 A, Fast 2387747 MPCB - F2 (illustration 6) 600 Vac, 20 A, Fast 2387747 Note: If you are changing the F5 or F6 fuse on the PDU Board, do the following: • If the PDU Board Part Number is 2365871-7 or below, order PDU Board 2365871-8 and change the entire PDU Board it according to Job Card D/R A191 - PDU Board on page 1137. • If the PDU Board Part Number is 2365871-8, order the fuse 5344386-2 and change it according to this Job Card. Page no. 1109 JC-DR-A-150.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A150 - System Fuses 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: Approximately 60 minutes 4 SAFETY PRECAUTIONS WARNING The Senographe system must be powered off and LOTO applied. Switch off the electrical power supply from the Mains Distribution Panel in the room. Apply an appropriate LOTO padlock and label. If changing a fuse within the Generator, wait 10 minutes for the components within the Generator to discharge. 5 PREREQUISITES You will have probably already removed the Generator or Gantry covers during trouble-shooting tasks to determine you need to change a fuse. However, if necessary, do the following: • If you are changing fuses on the Compression Board, remove the Compression Arm covers to access the Compression Board. Refer to section 8 in Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. • If you are changing fuses on the PDU Board, remove the Column covers to access the PDU Board. Refer to section 7 in Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. • If you are changing a fuse on one of the boards in the Generator, remove the Generator covers. Refer to Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513. 5-1 Ensure Capacitors on Generator Boards are Discharged If you are changing a fuse on one of the Generator boards, ensure that the capacitors are fully discharged before touching the fuses on those boards. For more information, refer to the one of the appropriate sections below: • section 5-1-1, Ensure that the Generator Command Board Capacitors are Discharged on page 1111 • section 5-1-2, Ensure that the Generator Supply Command Board Capacitors are Discharged on page 1112 • section 5-1-3, Ensure that the Mains Distribution Board Capacitors are Discharged on page 1115 Chapter 9 Page no. 1110 JC-DR-A-150.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A150 - System Fuses 5-1-1 Ensure that the Generator Command Board Capacitors are Discharged 1. Wait 10 minutes for the components within the Generator to discharge. 2. Switch off the electrical power supply on the rotary switch in the Generator cabinet (position 0). 3. Using a voltmeter (rating 1000 V DC), check that there is no residual voltage between screws S1 and S2 before proceeding. RC1 RC2 S1 S2 WARNING Residual voltage stored in the resonant capacitors can be dangerous. Ensure that the resonant capacitors are fully discharged before you handle the fuses on the Generator Command board. Page no. 1111 JC-DR-A-150.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A150 - System Fuses 5-1-2 Ensure that the Generator Supply Command Board Capacitors are Discharged 1. Wait 10 minutes for the components within the Generator to discharge. 2. Switch off the electrical power supply on the rotary switch in the Generator cabinet (position 0). 3. Using a voltmeter (rating 1000 V DC), check that there is no residual voltage between screws S1 and S2 before proceeding. RC1 RC2 S1 S2 WARNING Residual voltage stored in the resonant capacitors can be dangerous. Ensure that the resonant capacitors are fully discharged before you handle the Generator Supply Command board. 4. The XJ6 and XJ7 connectors may still have a residual voltage of 35V DC from the C2 capacitor located behind the Generator Supply Command board. Using a voltmeter (rating 1000 V DC), check Chapter 9 Page no. 1112 JC-DR-A-150.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A150 - System Fuses that there is no residual voltage (35V DC) between the XJ6 and XJ7 connectors. XJ6 XJ7 C1P M1P 5. The C1P and M1P connectors may still have a residual voltage of 250V DC from the C1 capacitor located behind the Generator Supply Command board. Using a voltmeter (rating 1000 V DC), check Page no. 1113 JC-DR-A-150.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A150 - System Fuses that there is no residual voltage (250V DC) between the C1P and M1P connectors. C2 C1 XJ6 XJ7 C1P M1P WARNING Residual voltage stored in the C1 and C2 capacitors (located behind the Generator Command Supply board can be dangerous. Ensure that the capacitors are fully discharged before you handle the fuses on the Generator Supply Command board. Chapter 9 Page no. 1114 JC-DR-A-150.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A150 - System Fuses 5-1-3 Ensure that the Mains Distribution Board Capacitors are Discharged 1. Wait 10 minutes for the components within the Generator to discharge. WARNING It is important that you switch off the external power supply on the Mains Distribution Panel. This is because you will be working in close proximity to where the external voltage arrives into the Generator. 2. Switch off the electrical power supply on the rotary switch in the Generator cabinet (position 0). 3. Using a voltmeter (rating 1000 V DC), check that there is no residual voltage between screws S1 and S2 before proceeding. RC1 RC2 S1 S2 WARNING Residual voltage stored in the resonant capacitors can be dangerous. Ensure that the resonant capacitors are fully discharged before you handle the Mains Distribution board. 4. The XJ8 and XJ9 connectors may still have a residual voltage of 600V DC from the C1, C2, C5, C6, C7, and C8 capacitors located behind the Mains Distribution board. Using a voltmeter (rating 1000 V DC), check that there is no residual voltage (600V DC) between the XJ8 and XJ9 connectors connec- Page no. 1115 JC-DR-A-150.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A150 - System Fuses tors. XJ8 Chapter 9 XJ9 Page no. 1116 JC-DR-A-150.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A150 - System Fuses C6 C8 C2 C1 C7 C5 XJ8 XJ9 WARNING Residual voltage stored in the C1, C2, C5, C6, C7, and C8 capacitors (located behind the Mains Distribution board can be dangerous. Ensure that the capacitors are fully discharged before you handle the fuse on the Mains Distribution board. Page no. 1117 JC-DR-A-150.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A150 - System Fuses 6 PROCEDURE 1. Refer to the appropriate illustration for the position of the fuse you want to change. • For the Main Distribution Assembly fuse locations, refer to illustration 1. • For the Generator Command Board fuse locations, refer to illustration 2. • For the Generator Supply Command Board fuse locations, refer to illustration 3. • For the Generator Main fuse locations, refer to illustration 4. • For the Mains Distribution Board fuse locations, refer to illustration 5. • For the PDU Board fuse locations, refer to illustration 6. • For the MPCB Board fuse locations, refer to illustration 6. 2. If changing a fuse within the Generator, ensure that the components in the Generator are fully discharged according to the steps described in section 5-1, Ensure Capacitors on Generator Boards are Discharged on page 1110. 3. Change the fuse. 4. Power up the system and ensure that the system operates as expected without error. Chapter 9 Page no. 1118 JC-DR-A-150.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A150 - System Fuses ILLUSTRATION 1 - MAINS DISTRIBUTION ASSEMBLY FUSES Mains Distribution Assembly Fuse (F1, F2, F3, F4, F5) locations on Mains Distribution Assembly F1 J3 DS1 DS2 J4 J1 DS3 F2 TP1 DS4 DS5 J5 DS6 DS7 F5 F4 J2 F3 DS8 TP2 TP3 J8 J6 J7 DS9 J9 Page no. 1119 JC-DR-A-150.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A150 - System Fuses ILLUSTRATION 2 - GENERATOR COMMAND BOARD FUSES Generator Command Board Fuse (F1, F2, F3) locations on Generator Command Board XJ6 DS1 DS2 XJ2 DS3 TP4 TP1 TP2 TP3 TP6 TP9 TP5 TP10 XJ4 TP7 TP8 TP22 TP21 TP23 TP24 TP25 TP26 TP27 TP28 TP35 TP37 TP33 TP34 TP32 TP40 TP39 TP38 TP36 TP29 TP31 TP41 GND1 TP42 DS4 TP43 GND2 DS5 DS6 TP44 TP45 TP47 F1 XJ3 TP54 F2 DS9 DS11 TP49 TP48 TP50 TP52 F3 DS7 TP46 TP55 TP53 TP59 TP58 GND3 DS12 TP62 TP60 TP64 TP51 TP66 XJ7 TP63 TP68 XJ9 DS10 TP57 GND4 TP56 TP51 DS8 TP69 TP70 TP73 TP74 DS13 TP65 TP77 TP71 TP79 GND5 TP78 TP75 TP76 TP80 TP82 TP89 TP84 TP83 TP87 TP88 XJ5 Chapter 9 TP81 TP90 TP85 XJ11 XJ12 TP67 TP86 XJ10 TP72 XJ8 XJ13 Page no. 1120 JC-DR-A-150.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A150 - System Fuses ILLUSTRATION 3 - GENERATOR SUPPLY COMMAND BOARD FUSES Generator Supply Command Board Fuse (F1, F2, F3, F4, F5, F5) locations on Generator Supply Command Board XJ3 F1 XJ4 F3 TP1 XJ9 XJ8 F2 0VV TP4 TP9 F6 TP5 XJ3 XJ1 TP2 TP3 TP6 TP7 TP8 TP10 TP12 XJ10 TP13 XJ6 TP15 P250V P27V XJ7 0V/27V XJ2 TP16 TP19 TP18 0V/250V TP19 F5 XJ5 TP21 F4 TP19 Page no. 1121 JC-DR-A-150.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A150 - System Fuses ILLUSTRATION 4 - GENERATOR MAIN FUSES F1 and F2 Main System Fuses Chapter 9 Page no. 1122 JC-DR-A-150.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A150 - System Fuses ILLUSTRATION 5 - MAINS DISTRIBUTION BOARD FUSES Mains Distribution Board Fuse (F1, F2, F3) locations on Mains Distribution Board XJ7 XJ8 XJ14 XJ11 XJ10 XJ12_2 XJ6 DE1 XJ5 XJ12_1 XJ13_2 XJ13_1 XJ4 PT1 N2 DE2 PT3 DE3 PT2 DE4 DE5 N1 SW2 F2 F3 PT8 PT4 PT5 PT6 PT7 SW1 PT9 0VE P1 PT10 XJ2 PT12 PT13 PT14 XJ1 PT11 DE9 DE8 XJ3 DE6 DE7 F1 IN2 PT16 PT15 PT17 PT18 P2 PT19 PT20 Page no. 1123 JC-DR-A-150.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A150 - System Fuses ILLUSTRATION 6 - PDU BOARD FUSES AND MPCB FUSES PDU Board MPCB Fuses (F1 and F2) DS15, 18 DS25 Chapter 9 J1 DS26 F6 DS1 F5 J4 J2 DS2 DS21‐20‐19‐17‐16 J5 Left Hand Side of Gantry Column PRGM DS24 F4 F3 J7 J3 S4 J22 J11 DS14‐13‐11‐10‐12‐9 J10 J9 DS8 DS7 DS6 F1 J6 S3 DS5 S2 S1 J8 Fuse (F1, F3, F4, F5, F6) locations on PDU Board Page no. 1124 JC-DR-A-150.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A189 - Interface Board Job Card D/R A189 - Interface Board 1 Chapter 9 SUPPLIES Interface board 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 40 minutes 4 SAFETY PRECAUTIONS WARNING • The Gantry must be powered off. When handling circuit boards, take precautions against damage by ESD (electro-static discharge). 5 PREREQUISITES None 6 PROCEDURE 6-1 Removing the Interface Board 1. Remove the Gantry CPU board from the Interface board according to Removing the Gantry CPU Board on page 1131 in Job Card D/R A190 - Gantry CPU Board. 2. Disconnect all the cables and optical fibers from the Interface board and make a mental note where they connect to on the Interface board. Ensure that you do not move them too much so it is easier to re-connect them later on. CAUTION Disconnect with caution to avoid damage to the connectors and cables. Page no. 1125 JC-DR-A-189.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A189 - Interface Board 3. Remove the three screws (1) securing the Interface board (cross-head screwdriver). 1 2 4. Remove the four threaded nuts (2) securing the Interface board, and remove the Interface board. 5. Put the defective Interface board in an anti-static bag. Chapter 9 Page no. 1126 JC-DR-A-189.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A189 - Interface Board 6-2 Replacing the Interface Board 1. Install the replacement Interface board and secure it using the four threaded nuts (1) and three screws (2) (cross-head screwdriver). J1 J8 J9 J6 J10 J7 1 J4 2 J3 J5 J2 J11 Eth 2. Connect all the cables to the new Interface board as summarized in the diagram above and table below. Ensure that the Ethernet cable is fully visible and does NOT go behind the PDU board. Ensure that all the other cables are routed away from the Interface board, and that the stop button cable which connects to J7 is routed around the Interface board and NOT behind the Interface board. Page no. 1127 JC-DR-A-189.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A189 - Interface Board Connector Label Description of cable (usually identified by code on a yellow label) Cable color J1 J1/PL104-W116 Gray J2 J2/PL104-W101 Gray J3 J3/PL104-W208 Gray J4 J4/PL104-W402 Black J5 J5/PL104-W314 Gray J6 J6/PL104-W216 Black J7 J7/PL104-W217 Black J8 W121 - PL104 - J8 (to top fiber connector) Black J9 W120 - PL104 - J9 (to middle fiber connector) Black J10 W119 - PL104 - J10 (to bottom fiber connector) Black J11 Empty N/A Eth Switch-AWS (RJ-45 connector at bottom) Gray 3. Ensure that jumper TP1 (3) that is to the left of the J4 connector on the Interface board is open. 3 4. Re-install the Gantry CPU board on the Interface board according to Replacing the Gantry CPU Board on page 1133 in Job Card D/R A190 - Gantry CPU Board. 5. Lift the top metal panel up to release it from the left side of the framework and replace it over the framework to hide the newly installed Gantry CPU board. 6. Switch on the Gantry electrical power. 7. Wait until the Gantry boot is complete, and check that no error has been reported. If the Interface board is operating correctly, the LED states are as follows: • all three of the green LEDs in the upper part of the Interface CPU board near the fiber connectors J8, J9 and J10 (i.e. DS1, DS2, and DS3) are ON • the green LEDs DS8 and DS11 near the J5 connector are blinking (i.e. there is network activity on the Ethernet connection) • all the other green LEDs near the J5 connector (i.e. DS4, DS5, DS6, DS7, DS9, DS10, DS12, and DS13) are OFF 8. Reinstall the column cover (CPU side); refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. Chapter 9 Page no. 1128 JC-DR-A-189.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A189 - Interface Board 7 COMPLETION Once you have changed the Interface board, you must perform the completion steps described below in the following order: • section 7-1, Software Check • section 7-2, Calibrations 7-1 Software Check Check whether the new Interface Board software needs to be updated, as follows: 1. Reboot the Senographe system. 2. Go to the Service Desktop home page (see Launching the Service Desktop on page 120). 3. Consult Table 1 on page 63 in the section Component FW/SW to ADS Version compatibility Matrix on page 63. Determine the system level from the ADS/IDC/Generator CPU versions displayed on the Service Desktop home page, and by consulting Table 1 on page 63. The system level will be defined by one of the System Level (Model Number) columns in Table 1 on page 63. 4. Check whether the current software version for the new Interface Board corresponds to the required firmware version for the that system level. • If the current software version matches the required version quoted in Table 1 on page 63, no additional steps are required. • If the current software version does not match the required version, you must perform a sofware update of the mismatched software version so that the new interface Board software version matches that quoted in Table 1 on page 63. To update the new Interface Board software follow the instructions supplied in the Gantry Software Update CD-ROM that is kept with the system. 7-2 Calibrations Carry out the following calibrations: Calibrations - Checks Check all Gantry motions Job Card Job Card ELE A015 - Gantry Functional Checks on page 579 Page no. 1129 JC-DR-A-189.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A189 - Interface Board This page is blank. Chapter 9 Page no. 1130 JC-DR-A-189.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A190 - Gantry CPU Board Job Card D/R A190 - Gantry CPU Board 1 Chapter 9 SUPPLIES Gantry CPU board 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS WARNING • The Gantry must be powered off. When handling circuit boards, take precautions against damage by ESD (electro-static discharge). 5 PREREQUISITES None 6 PROCEDURE CAUTION Collimator parameters are saved in the CPU board memory. It will be necessary to recalibrate the collimator after changing the board. Other Gantry settings are stored in the node boards (i.e., lift parameters in the lift board, tube tilt parameters in the tilt board, etc.). If the node boards are not changed, it is not necessary to repeat these calibrations. 6-1 Removing the Gantry CPU Board 1. Switch off the Senographe electrical power. 2. Remove the column cover (CPU side only); refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. 3. Lift the top metal panel (1) up using its handles (2) to release it from the framework. Hook it on to the Page no. 1131 JC-DR-A-190.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A190 - Gantry CPU Board latches on the left side of the framework to expose the Gantry CPU board (3). 1 3 2 4. Remove the four screws (4) securing the Gantry CPU board (cross-head screwdriver). 4 4 5. Carefully pull the top part of the Gantry CPU board to remove it from the Interface board. Apply equal force to both sides of the Gantry CPU board to ensure that you do not damage the two connectors on the Interface board. 6. Put the defective Gantry CPU board in an anti-static bag. Chapter 9 Page no. 1132 JC-DR-A-190.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A190 - Gantry CPU Board 6-2 Replacing the Gantry CPU Board 1. Take the new Gantry CPU board out of its anti-static bag, and inspect it to ensure that the TP2 connector is open. If a jumper (i.e. black plastic with metal insets) is present then remove it from the blue plastic socket of the TP2 connector. Blue plastic socket TP2 Connector ! Notice: The TP2 connector is only ever closed with a jumper during the manufacturing phase of the Gantry CPU board, when the base software is initially programmed. A jumper must never be present on the TP2 connector in the field. However, the TP2 connector must only contain blue plastic socket. This socket is normal and does not act as a jumper as it contains no conductive material. Do not attempt to remove the blue plastic socket as you risk damaging the TP2 connector. 2. Carefully push the new Gantry CPU board into the two connectors (1) of the Interface board. Apply equal force to both sides of the Gantry CPU board to ensure that you do not damage the two connectors on the Interface board. 1 3. Secure the new Gantry CPU board to the Interface board with the four screws (2) (cross-head screwdriver). To prevent damage to the Gantry CPU board, ensure that you do not overtighten the screws. Page no. 1133 JC-DR-A-190.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A190 - Gantry CPU Board To prevent damage to the connectors on the Interface Board, ensure that the top screws are progressively tightened on each side. 2 2 4. Switch on the Gantry electrical power. 5. Wait until the Gantry boot is complete, and check that no error has been reported. If the Gantry CPU board is operating correctly, the LED states are as follows: • all three of the green LEDs in the upper part of the Gantry CPU board (i.e. DS1, DS2, and DS3) are ON • the first eight of the block of yellow LEDs starting on the left (i.e. DS4, DS5, DS6, DS7, DS8, DS9, DS10, and DS11) blink in a cycling fashion from outside to inside • the last two of the block of yellow LEDs on the right-hand side (i.e. DS12 and DS13) are OFF 6. Switch off the Senographe electrical power. 7. Lift the top metal panel up to release it from the left side of the framework. Put it back over the framework to hide the newly installed Gantry CPU board. 8. Reinstall the column cover (CPU side); refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. Chapter 9 Page no. 1134 JC-DR-A-190.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A190 - Gantry CPU Board 7 COMPLETION Once you have changed the Gantry CPU board, you must perform the completion steps described below in the following order: • section 7-1, Software Check • section 7-2, Calibrations 7-1 Software Check Check whether the new Gantry CPU board software needs to be updated, as follows: 1. Reboot the Senographe system. 2. Go to the Service Desktop home page (see Launching the Service Desktop on page 120). Check whether the current software version for the newly replaced Gantry CPU board corresponds to the required software version for the current the ADS Application Software version that is running on the system. Consult the table in the section Component FW/SW to ADS Version compatibility Matrix on page 63 for the compatible software versions of the Gantry CPU board corresponding to the different ADS Application Software versions. 3. If the Gantry CPU board current software version does not match the required software version, you must perform a software update of the newly replaced Gantry CPU board according to the instructions supplied in the Gantry Software Update CD-ROM. Note: The TP2 connector is only ever closed with a jumper during the manufacturing phase of the Gantry CPU board, when the base software is initially programmed. A jumper must never be present on the TP2 connector in the field. Therefore, if you need to update the Gantry CPU you do not need to close the TP2 connector with a jumper. 7-2 Calibrations Carry out the following calibrations: Calibrations - Checks Job Card Acquisition Image Chain Collimator Calibration Job Card CAL A029 - Collimator Format Calibration on page 1683 Collimation Check Job Card ELE A028 - Collimation Checks on page 679 If Collimation Check not OK, repeat Collimator Calibration Page no. 1135 JC-DR-A-190.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A190 - Gantry CPU Board This page is blank. Chapter 9 Page no. 1136 JC-DR-A-190.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A191 - PDU Board Job Card D/R A191 - PDU Board 1 Chapter 9 SUPPLIES PDU Board 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS WARNING • The Gantry must be powered off. When handling circuit boards, take precautions against damage by ESD (electro-static discharge). 5 PREREQUISITES None 6 PROCEDURE 6-1 Removal and Replacement of the PDU Board 1. Switch off the Senographe electrical power. 2. Remove the left column cover; refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. 3. Lift the top metal panel (1) up using its handles (2) to release it from the framework. Hook it on to the Page no. 1137 JC-DR-A-191.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A191 - PDU Board latches on the left side of the framework to expose the PDU board (3). 1 3 2 4. Disconnect all the cables from the PDU board and make a mental note where they connect to on the PDU board. Ensure that you do not move them too much so it is easier to re-connect them later on. CAUTION Disconnect with caution to avoid damage to the connectors and cables. 5. Remove the six screws (4) securing the PDU board (cross-head screwdriver), and remove the PDU board. 4 Chapter 9 4 Page no. 1138 JC-DR-A-191.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A191 - PDU Board 6. Put the defective PDU board into an anti-static bag. 7. Install the replacement PDU board and secure it with the six screws (4) (cross-head screwdriver). 4 4 8. Connect all the cables to the new PDU board as summarized in the diagram and table below. To avoid potential EMC interference ensure that all the cables are routed around (away from) the PDU board. J8 J9 J10 J6 J7 J3 J5 J2 J4 J1 Page no. 1139 JC-DR-A-191.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A191 - PDU Board PDU board cable connections: Connector Label Description of cable (usually identified by code on a yellow label) Cable color J1 J1/PL101-W104 Gray J2 J2/PL101-W125 White J3 No code, but cable ends with a gray ribbon cable Black J4 2345987 Black J5 J5/PL101-W110 Gray J6 J6/PL101-W315 Gray J7 Three cables arriving at the same physical connector: J7/PL101-W114 J7/PL101-W209 2345992 Black Gray Gray J8 J8/PL101-W101 Gray J9 No cable attached N/A J10 No cable attached N/A 9. Ensure that jumper JP22 (5) on the PDU board is open and only connected to the very top connector. 5 10. Ensure that jumper PRGM (6) on the PDU board is open. 6 11. Switch on the Senographe electrical power. Chapter 9 Page no. 1140 JC-DR-A-191.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A191 - PDU Board 12. Switch on the Gantry electrical power (from the X-ray Console) and check that the Ganrty powers up. If the Gantry does not power up check that the JP22 jumper is not closed on the bottom two pins. 13. If the Gantry powers up, wait until the Gantry boot is complete, and check that no error has been reported. If the PDU board is operating correctly, the LED states are as follows: • all the green LEDs below and to the left of connector J3 (i.e. DS15, DS16, DS17, DS18, DS19, DS20, DS21, and DS22) are ON • all of the yellow LEDs above and to the left of connector J3 (i.e. DS9, DS10, DS11, DS12, DS13) and the red LED (i.e. DS14) are OFF • the red LED approximately in the middle of the PDU board (i.e. DS26) is OFF • the yellow LED approximately in the middle of the PDU board (i.e. DS25) is blinking and representing the watchdog heartbeat of the microcontroller on the PDU board • the green LEDs above and to the right of connector J2 (i.e DS1 and DS2) are ON • the four red LEDs towards the top left of the PDU board (i.e. DS5, DS6, DS7, and DS8) spell the word dEF. If only the third LED from the left shows a 0 and the other LEDs are not lit the PDU board is still in programming mode and you must ensure that the PRGM jumper is open. • the green LED at the bottom, middle part of the PDU board (i.e. DS26) is ON 14. Switch off the Gantry electrical power (form the X-ray Console) and check that the Gantry powers down. If the Gantry does not power down check that the JP22 jumper is not closed on the top two pins. 15. Switch off the Senographe electrical power. 16. Lift the top metal panel up to release it from the left side of the framework. Put it back over the framework to hide the newly installed the newly installed PDU board. 17. Reinstall the left column cover; refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. Page no. 1141 JC-DR-A-191.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A191 - PDU Board This page is blank. Chapter 9 Page no. 1142 JC-DR-A-191.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A192 - Arm Distribution Board Job Card D/R A192 - Arm Distribution Board 1 Chapter 9 SUPPLIES Arm Distribution Board 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS WARNING • The Gantry must be powered off. When handling circuit boards, take precautions against damage by ESD (electro-static discharge). 5 PREREQUISITES None 6 PROCEDURE 6-1 Removal and Replacement of the Arm Distribution Board 1. Switch off the Senographe electrical power. 2. Remove the right column cover; refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. 3. Disconnect all the cables from the Arm Distribution board and make a mental note where they connect to on the Arm Distribution board. Ensure that you do not move them too much so it is easier to re-connect them later on. CAUTION Disconnect with caution to avoid damage to the connectors and cables. 4. Remove the four screws (1) securing the Arm Distribution board (3 mm allen wrench), and remove Page no. 1143 JC-DR-A-192.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A192 - Arm Distribution Board the Arm Distribution board. 1 1 5. Put the defective Arm Distribution board into an anti-static bag. 6. Install the replacement Arm Distribution board and secure it with the four screws (1) (3 mm allen wrench). Secure the top two screws first, then the bottom right screw. When you secure the bottom left screw, ensure that you have metal connector (2) that surrounds cable J7/PL301 attached to the screw so that is secured to the Arm Distribution board. 2 7. Connect all the cables to the new Arm Distribution board as summarized in the diagram and table Chapter 9 Page no. 1144 JC-DR-A-192.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A192 - Arm Distribution Board below. J3 J9 J10 J4 J6 J5 J11 J2 J8 J7 J1 Arm Distribution board cable connections: Connector Label Description of cable (usually identified by code on a yellow label) Cable color J1 J1/PL301-W314 (2345920-2) Gray J2 J2/PL301-W315 (2345921) Gray J3 J3/PL301-W503 (5143848) Black J4 J4/PL301-W310 (5139723) Gray J5 J5/PL301-W307 (2371179) Gray J6 J6/PL301-W308 (2372181) Gray J7 J7/PL301-W409 (2345934) Gray J8 J8/PL301-W401 (2345926) Gray J9 J9/PL301-W411 (2345919) Gray J10 J10/PL301-W410 (2345918) Gray J11 No cable attached N/A 8. Switch on the Gantry electrical power. 9. Wait until the Gantry boot is complete, and check that no error has been reported. 10. Switch off the Gantry electrical power. 11. Reinstall the right column cover; refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. Page no. 1145 JC-DR-A-192.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A192 - Arm Distribution Board 7 COMPLETION After changing the Arm Distribution board, no calibrations are necessary. Chapter 9 Page no. 1146 JC-DR-A-192.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A193 - AC/DC Board Job Card D/R A193 - AC/DC Board 1 Chapter 9 SUPPLIES AC/DC Board 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS WARNING • The Gantry must be powered off. When handling circuit boards, take precautions against damage by ESD (electro-static discharge). 5 PREREQUISITES None 6 PROCEDURE 1. Switch off the Senographe electrical power. 2. Remove the left column cover; refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. 3. Lift the top metal panel (1) up using its handles (2) to release it from the framework. Hook it on to the Page no. 1147 JC-DR-A-193.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A193 - AC/DC Board latches on the left side of the framework. 1 2 4. Lift the bottom metal panel (3) up using its handles (4) to release it from the framework. 3 4 Chapter 9 Page no. 1148 JC-DR-A-193.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A193 - AC/DC Board 5. Remove the ground cable (5) (8 mm open ended wrench) from the bottom metal panel, and place the bottom metal panel in a safe place. 5 6. Removing the bottom metal panel exposes the AC/DC Module (6), AC/DC Board (7) and associated cabling. In this Job Card, you are only replacing the AC/DC Board. 6 7 7. Disconnect the J138/PL107-W107 cable (8) and the J137/PL102-W106 cable (9) from the Page no. 1149 JC-DR-A-193.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A193 - AC/DC Board AC/DC Board (7). AC/DC Module 8 7 10 12 9 11 CAUTION Disconnect with caution to avoid damage to the connectors and cables. 8. Disconnect the W004 ground cable (10) from the AC/DC Board (7) (screwdriver and 7.5 mm openended wrench). 9. Remove the two nuts (11) (8 mm open-ended wrench) that secure the L-shaped metal strip (12) to the framework and remove the L-shaped metal strip. 10. Carefully remove the AC/DC Board from the AC/DC Module by gently pushing down on the AC/ DC Board. Apply even pressure on both sides of the AC/DC Board so that you do not distort the pins that are located in the AC/DC Module black plastic connector. The AC/DC Board will slide away from the black plastic connector that secures it to the AC/DC Module. 11. Put the defective AC/DC Board into an anti-static bag. 12. Carefully insert the new AC/DC Board (13) into the AC/DC Module by gently pushing it up into the AC/DC Board black plastic connector. Apply even pressure on both sides of the AC/DC Board so that you do not distort the pins that are located in the AC/DC Module black plastic connector. The AC/DC Board will remain in place due to the tight fit of the AC/DC Module black plastic connector. AC/DC Module 18 13 16 14 17 15 13. Put the L-shaped metal strip (14) in place below the AC/DC Board and secure it to the framework Chapter 9 Page no. 1150 JC-DR-A-193.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A193 - AC/DC Board with the two nuts (15) (8 mm open-ended wrench). 14. Connect the W004 ground cable (16) to the new AC/DC Board (13) (screwdriver and 7.5 mm openended wrench). 15. Connect the J137/PL102-W106 cable (17) and the J138/PL107-W107 cable (18) to the new AC/DC Board (13). 16. Switch on the Gantry electrical power. 17. Wait until the Gantry boot is complete, and check that no error has been reported. 18. Switch off the Gantry electrical power. 19. Re-attach the ground cable to the bottom metal (8 mm open ended wrench) cover and replace it over the framework to cover the newly installed AC/DC Board. 20. Lift the top metal panel up to release it from the left side of the framework and replace it over the framework. 21. Reinstall the left column cover; refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. 7 COMPLETION After changing the AC/DC Board, no calibrations are necessary. Page no. 1151 JC-DR-A-193.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A193 - AC/DC Board This page is blank. Chapter 9 Page no. 1152 JC-DR-A-193.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A194 - AC/DC Module Job Card D/R A194 - AC/DC Module 1 Chapter 9 SUPPLIES AC/DC Module 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS WARNING • The Gantry must be powered off. When handling circuit boards, take precautions against damage by ESD (electro-static discharge). 5 PREREQUISITES None 6 PROCEDURE 6-1 Remove the Defective AC/DC Module 1. Switch off the Senographe electrical power. 2. Remove the left column cover; refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. 3. Lift the top metal panel (1) up using its handles (2) to release it from the framework. Hook it on to the Page no. 1153 JC-DR-A-194.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A194 - AC/DC Module latches on the left side of the framework. 1 2 4. Lift the bottom metal panel (3) up using its handles (4) to release it from the framework. 3 4 Chapter 9 Page no. 1154 JC-DR-A-194.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A194 - AC/DC Module 5. Remove the ground cable (5) (8 mm open ended wrench) from the bottom metal panel, and place the bottom metal panel in a safe place. 5 6. Removing the bottom metal panel exposes the AC/DC Module (6), AC/DC Board (7) and associated cabling. In this Job Card you are only replacing the AC/DC Module, but you will need to move the AC/DC Board. 6 7 7. Disconnect the J138/PL107-W107 cable (8) and the J137/PL102-W106 cable (9) from the Page no. 1155 JC-DR-A-194.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A194 - AC/DC Module AC/DC Board (7). AC/DC Module 8 7 10 12 9 11 CAUTION Disconnect with caution to avoid damage to the connectors and cables. 8. Disconnect the W004 ground cable (10) from the AC/DC Board (7) (screwdriver and 7.5 mm openended wrench). 9. Remove the two nuts (11) (8 mm open-ended wrench) that secure the L-shaped metal strip (12) to the framework and remove the L-shaped metal strip. 10. Carefully remove the AC/DC Board from the AC/DC Module by gently pushing down on the AC/ DC Board. Apply even pressure on both sides of the AC/DC Board so that you do not distort the pins that are located in the AC/DC Module black plastic connector. The AC/DC Board will slide away from the black plastic connector that secures it to the AC/DC Module. 11. Put the AC/DC Board into an anti-static bag. 12. Disconnect the J1-AC/DC Module W109 cable (13) from the AC/DC Module (7 mm open ended wrench). 13 14 13. Disconnect the J2-AC/DC Module W1112 cable (14) from the AC/DC Module (10 mm open ended wrench). 14. Disconnect the W005 ground cable (15) from the AC/DC Module (5 mm open ended wrench) and Chapter 9 Page no. 1156 JC-DR-A-194.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A194 - AC/DC Module leave the other end connected to the framework. 15 15. Remove the four nuts (16) (8 mm socket and torque wrench) that secure the defective AC/DC Module to the framework, and remove the defective AC/DC Module. AC/DC Module 16 16 Page no. 1157 JC-DR-A-194.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A194 - AC/DC Module 6-2 Install the New AC/DC Module 1. Put the new AC/DC Module in place and secure it to the framework with the four nuts (1) (8 mm socket and torque wrench). AC/DC Module 1 1 2. Take the existing AC/DC Board that you had stored in an anti-static bag, and carefully insert the AC/DC Board (2) into the AC/DC Module by gently pushing it up into the AC/DC Board black plastic connector. Apply even pressure on both sides of the AC/DC Board so that you do not distort the pins that are located in the AC/DC Module black plastic connector. The AC/DC Board will remain in place due to the tight fit of the AC/DC Module black plastic connector. AC/DC Module 7 2 5 3 6 4 3. Put the L-shaped metal strip (3) in place below the AC/DC Board and secure it to the framework with the two nuts (4) (8 mm open-ended wrench). 4. Connect the W004 ground cable (5) to the AC/DC Board (13) (screwdriver and 7.5 mm open-ended wrench). Chapter 9 Page no. 1158 JC-DR-A-194.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A194 - AC/DC Module 5. Connect the J137/PL102-W106 cable (6) and the J138/PL107-W107 cable (7) to the AC/DC Board. 6. Connect the W005 ground cable (8) to the new AC/DC Module (5 mm open ended wrench). 8 7. Connect the J2-AC/DC Module W1112 cable (9) to the new AC/DC Module (7 mm open ended wrench). 10 9 8. Connect the J1-AC/DC Module W109 cable (10) to the new AC/DC Module (10 mm open ended wrench). 9. Switch on the Gantry electrical power. 10. Wait until the Gantry boot is complete, and check that no error has been reported. 11. Switch off the Gantry electrical power. 12. Re-attach the ground cable to the bottom metal cover (8 mm open ended wrench) and replace it over the framework to cover the newly installed AC/DC Board. 13. Lift the top metal panel up to release it from the left side of the framework and replace it over the framework. 14. Reinstall the left column cover; refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. 7 COMPLETION After changing the AC/DC Board, no calibrations are necessary. Page no. 1159 JC-DR-A-194.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A194 - AC/DC Module This page is blank. Chapter 9 Page no. 1160 JC-DR-A-194.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A201 - Lift Board Job Card D/R A201 - Lift Board 1 Chapter 9 SUPPLIES Lift Board 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 • • PREREQUISITES Switch off the system power. Remove the column covers (Refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. 6 PROCEDURE 6-1 Disassembly of Lift Board Read the following procedure to replace the Lift Board. Lift Board 1. Carefully disconnect all the cables from the Lift Board. Pay attention to how the cables are routed around the sides of the Lift Board. You will need to re-connect them in the same way on the replacement Lift Board. Page no. 1161 JC-DR-A-201.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A201 - Lift Board CAUTION Disconnect the cables with caution to avoid damage to the connectors. 1 1 2. Release the six screws (1) securing the Lift Board (cross-head screwdriver). 3. Put the defective Lift Board into an anti-static bag. Chapter 9 Page no. 1162 JC-DR-A-201.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A201 - Lift Board 6-2 Reassembly of the Lift Board 1. Put the new Lift Board in place being careful not to pinch any of the existing cables in the area. 1 J6 J4 J2 J13 J9 J12 J23 J1 J14 J3 J10 J21 J4 J5 J17 J16 J22 J15 1 2. Use the six screws (1) to secure the new Lift Board (cross-head screwdriver) to the side of the Gantry. 3. Carefully reconnect all of the cables to the new Lift Board as summarized in the diagram above and table below. Page no. 1163 JC-DR-A-201.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A201 - Lift Board ! Notice: When reconnecting all the cables to the Lift Board, ensure that you route them so they do not pass over Lift Board as illustrated in the diagram above. This precaution avoids potential interference caused by component electronic noise. Lift Board cable connections. Connector Label Description of cable (usually identified by code on a yellow label) Cable color J1 J1/PL201-W210 Gray J2 J2/PL201-W209 Gray J4 J4/PL201-W201 Gray J5 J5/PL201-W202 Gray J6 If the Senographe system has a Type 1 Lift Screw Assembly (no brake), no cable is attached. Black (if brake exists) If the Senographe system has a Type 2 Lift Screw Assembly, and has been fitted with a Top Brake, a black cable with no label, leading up to the Top Brake located at the top of the Lift Screw Assembly If the Senographe system has a Type 3 Lift Screw Assembly, a black cable with no label, going to the Motor Brake located in the Lift Motor at the bottom of the Lift Screw Assembly J9 J9/PL201 or PL202 - W205 Black J10 J10/PL201 or PL202 - W206 Black/Grey J11 J11/PL201-W203 Gray J12 J12/PL201-W211 Gray J13 J13/PL201-W208 Gray J14 J14/PL201-W213 Gray J15 Gray ribbon cable to the Gantry digital display Gray J16 Footwsitch cable with 9 pin D-sub connector N/A J17 Footwsitch cable with 9 pin D-sub connector N/A J21 No cable attached N/A J22 No cable attached N/A J23 No cable attached N/A Chapter 9 Page no. 1164 JC-DR-A-201.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A201 - Lift Board 7 COMPLETION 7-1 Firmware Check Check whether the new Lift Board firmware needs to be updated, as follows: 1. Reboot the Senographe system. 2. Go to the Service Desktop home page (see Launching the Service Desktop on page 120). 3. Consult Table 1 on page 63 in the section Component FW/SW to ADS Version compatibility Matrix on page 63. Determine the system level from the ADS/IDC/Generator CPU versions displayed on the Service Desktop home page, and by consulting Table 1 on page 63. The system level will be defined by one of the System Level (Model Number) columns in Table 1 on page 63. 4. Check whether the current firmware version(s) for the new Lift Board corresponds to the required firmware version for the that system level. • If the current firmware version(s) match the required version(s) quoted in Table 1 on page 63, no additional steps are required. • If the current firmware version(s) does not match the required version(s), you must perform a firmware update of the mismatched firmware version(s) so that the new Lift Board firmware version(s) match those quoted in Table 1 on page 63. To update the new Lift Board firmware follow the instructions supplied in the Gantry Software Update CD-ROM that is kept with the system. Page no. 1165 JC-DR-A-201.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A201 - Lift Board 7-2 Check Gantry Readout Cable Position To ensure that there is no EMC interference between the Lift Board and the Gantry Readout ribbon cable, ensure that the Gantry Readout ribbon cable is correctly positioned. Refer to Check Gantry Readout Cable Position on page 1216 in Job Card D/R A212 - Gantry Readout. 7-3 • • Calibrations Check that footswitches are working properly. Check if the readability of Gantry Readout text is acceptable. If needed, adjust the Gantry Readout Potentiometer on the Lift board until the text brightness/contrast is acceptable. For adjustment use a very small flat screwdriver (max. 1 mm wide). Gantry Readout Potentiometer • Carry out the calibration procedure: Job Card CAL A031 - Lift Calibration on page 1687. Chapter 9 Page no. 1166 JC-DR-A-201.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A202 - Upper Optical Fork Job Card D/R A202 - Upper Optical Fork 1 Chapter 9 SUPPLIES Upper Optical Fork 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 25 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 PREREQUISITES • Raise the arm to an intermediate position to facilitate the access to both upper (1) and lower (2) optical forks. • Switch off the system power. • Remove the Front cover and the right column cover (Refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. • Loosen and remove the Gantry curtain (refer to Job Card D/R A208 - Gantry Curtains on page 1193). 1 2 Page no. 1167 JC-DR-A-202.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A202 - Upper Optical Fork 6 PROCEDURE 6-1 Disassembly of Upper Optical Fork 1. Release the four bolts securing the lower X plate (10 mm open-ended wrench). 2. Disconnect the Upper Optical Fork cable (1) labeled J4/PL201 - W201 from the J4 connector on the Lift Board. J4 2 1 3. Carefully cut the cable ties (2) to unattach the Upper Optical Fork cable labeled J4/PL201 - W201 from the rest of the cables running up the right-hand side of the Lift Board. 4. Release the two screws securing the lower optical fork in order to free the Upper Optical Fork cable (W201) (2.5 mm allen wrench). Chapter 9 Page no. 1168 JC-DR-A-202.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A202 - Upper Optical Fork 5. Release the two screws securing the Upper Optical Fork (3) (2.5 mm allen wrench). 3 6-2 Reassembly of the Upper Optical Fork 1. Use the two screws to secure the new Upper Optical Fork (1) (2.5 mm allen wrench) to the Gantry frame. 1 2. Route the Upper Optical Fork cable (W201) down the Gantry framework past the position of the lower Optical Fork. Then use the two screws to secure the original Lower Optical Fork back into place (2.5 mm allen wrench). 3. Connect the Upper Optical Fork cable (2) labeled J4/PL201 - W201 from the new Upper Optical Fork Page no. 1169 JC-DR-A-202.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A202 - Upper Optical Fork to the J4 connector on the Lift Board 3 J4 2 4. Carefully secure the Upper Optical Fork cable (2) labeled J4/PL201 - W201 to the other cables using cable ties (3) as shown above. CAUTION When connecting the new Upper Optical Fork to the Lift Board, ensure that you route the W201 cable so it does not pass over Lift Board as shown above. This precaution avoids potential interference caused by component electronic noise. 5. Use the four bolts to secure the lower X plate (10 mm open-ended wrench) to the Gantry framework. 7 COMPLETION Check the lift motion operates as expected. Chapter 9 Page no. 1170 JC-DR-A-202.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A203 - Lower Optical Fork Job Card D/R A203 - Lower Optical Fork 1 Chapter 9 SUPPLIES Lower Optical Fork 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 25 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 PREREQUISITES • Raise the arm to its maximum height to access the lower optical fork (1). • Switch off the system power. • Remove the Front cover and the right column cover (Refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). • Loosen and remove the Gantry curtain under the arm (refer to Job Card D/R A208 - Gantry Curtains on page 1193). 1 Page no. 1171 JC-DR-A-203.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A203 - Lower Optical Fork 6 PROCEDURE 6-1 Disassembly of the Lower Optical Fork 1. Release the four bolts securing the lower X plate (10 mm open-ended wrench). 2. Disconnect the Lower Optical Fork cable (1) labeled J5/PL201 - W202 from the J5 connector on the Lift Board. J5 2 1 3. Carefully cut the cable ties (2) to unattach the Lower Optical Fork cable labeled J5/PL201 - W202 from the rest of the cables running up the right-hand side of the Lift Board. Chapter 9 Page no. 1172 JC-DR-A-203.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A203 - Lower Optical Fork 4. Release the two screws securing the Lower Optical Fork (3) (2.5 mm allen wrench). 3 6-2 Reassembly of the Lower Optical Fork 1. Use the two screws to secure the new Lower Optical Fork (1) (2.5 mm allen wrench) to the Gantry frame. 1 2. Route the Lower Optical Fork cable (W202) down to the location of the Lift Board. 3. Connect the Lower Optical Fork cable (2) labeled J5/PL201 - W202 from the new Lower Optical Fork Page no. 1173 JC-DR-A-203.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A203 - Lower Optical Fork to the J5 connector on the Lift Board 3 J5 2 4. Carefully secure the Lower Optical Fork cable (2) labeled J5/PL201 - W202 to the other cables using cable ties (3) as shown above. CAUTION When connecting the new Lower Optical Fork to the Lift Board, ensure that you route the W202 cable so it does not pass over Lift Board as shown above. This precaution avoids potential interference caused by component electronic noise. 5. Use the four bolts to secure the lower X plate (10 mm open-ended wrench) to the Gantry framework. 7 COMPLETION Check the lift motion operates as expected. Chapter 9 Page no. 1174 JC-DR-A-203.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A204 - Lift Potentiometer Job Card D/R A204 - Lift Potentiometer 1 Chapter 9 SUPPLIES Lift Potentiometer 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes (incl. calibrations and functional checks) 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 PREREQUISITES • Raise the arm to an intermediate height to access the lift potentiometer (1). • Switch off the Gantry power. • Remove the covers (See Job Card PHY A044 - Remove/ Reinstall Gantry Covers on page 523). • Loosen and remove the Gantry curtain under the arm (See Job Card D/R A208 - Gantry Curtains on page 1193). 1 Page no. 1175 JC-DR-A-204.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A204 - Lift Potentiometer 6 PROCEDURE 6-1 Disassembly of the Lift Potentiometer 1. Release the four bolts securing the lower X plate (10 mm open-ended wrench). 2. Disconnect from the lift board (2) the Cable W203: Potentiometer cable (connector J11). J11 2 3. Release without removing the four screws (3) securing the potentiometer (2.5 mm allen wrench). 4. Slide the potentiometer out of its supports. 3 Chapter 9 Page no. 1176 JC-DR-A-204.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A204 - Lift Potentiometer 5. Unhook the extremity of the position detecting wire (4). 4 6-2 Reassembly of the Lift Potentiometer 1. Remove the 4 small L-shaped attachment brackets and the 4 screws from the potentiometer attachment location. 2. Attach the new potentiometer with the same 4 attachment screws that were used with the old lift pot. See the orientation in the picture below. 3. Attach the potentiometer wire loop to the trolley hook. 4. Guide the potentiometer cable through the opening in the column back and connect it to the lift board. 7 • • COMPLETION Check that footswitches and Gantry Readout are working properly. Carry out the calibration procedure from Job Card CAL A031 - Lift Calibration on page 1687. Page no. 1177 JC-DR-A-204.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A204 - Lift Potentiometer This page is blank. Chapter 9 Page no. 1178 JC-DR-A-204.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A205 - Lift Motor Job Card D/R A205 - Lift Motor 1 Chapter 9 SUPPLIES Determine the type of Lift Screw Assembly that is installed in the system, as indicated below. TABLE 1 - LIFT SCREW ASSEMBLY TYPE IDENTIFICATION QUICK GUIDE Lift Type in Install Base System No brake (Type 1) Top brake (Type 2) Brake motor (Type 3) pre-January 2008 January 2008 June 2011 L-bracket at top of Lift Screw Assembly Black with no threaded holes Silver with threaded holes Silver with no threaded holes Motor power cable YES YES YES Motor earth cable NO YES YES Motor brake cable NO NO YES Manufacturing Date Physical Identification Method (required on Type 1 or Type 2 systems to know if Lift Screw Assembly upgraded to newer type) Order the appropriate Lift Motor according to the Type of Lift Screw Assembly installed in the system: • For systems with Type 1 and Type 2, order a Type1/Type 2 Compatible Lift Motor (5212900) • For systems with Type 3, order a Type 3 Lift Brake Motor (5413527) 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 45 minutes 4 SAFETY PRECAUTIONS WARNING While working on the column mechanism, shut down the equipment and switch off the Senographe hospital supply circuit breaker. Lock it in the off position or mark it clearly with a warning sign to prevent others from applying power. Page no. 1179 JC-DR-A-205.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A205 - Lift Motor 5 • • • • PREREQUISITES Raise the column as required for access to the lift motor (1). Switch off the system power. Remove the front and the column covers (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). Loosen and remove the Gantry curtain (refer to Job Card D/R A208 - Gantry Curtains on page 1193). 1 6 PROCEDURE 6-1 Disassembly of the Lift Motor 1. Release the bolts securing the lower X plate (2) (10 mm open-ended wrench) 2. Remove the curtain roller (3). 2 3 Chapter 9 Page no. 1180 JC-DR-A-205.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A205 - Lift Motor 3. Disconnect from the Lift Board (4): • Cable W206: Lift Motor power supply cable (connector J10) • Cable W205: Lift Motor Encoder cable (connector J9) J9 J6 4 J10 4. If an earth cable exists, disconnect the earth cable that is routed to the bottom left corner of the Detector Power Supply plate. 5. If a Motor Brake cable exists (Type 3 Lift Screw Assemblies), disconnect the Motor Brake cable that is connected to the J6 connector on the Lift Board. Earth cable routing. Page no. 1181 JC-DR-A-205.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A205 - Lift Motor 6. Release the four hex head screws (5) (4 mm allen wrench) securing the lift motor (6) Front view 5 6 Rear view 7. Remove the lift motor. 6-2 • Reassembly of the Lift Motor Reverse the disassembly procedure. The replacement Lift Motor will have an earth cable, so ensure you connect and route the earth cable to the bottom left corner of the Detector Power Supply plate as shown above. If you are installing the Type 3 Lift Brake Motor (5413527) you must also connect the Motor Brake cable to the J6 Connector on the Lift Board as shown above. 6-3 Check Column Movement 1. Move the compression paddle out of compression. Then check that all four sets of column up/down control buttons are operational (check each button for up and down movement of the column). 2. Move column to its upper and lower limits. Software limits should stop movement. If the software limits fail, the optical forks are used to recognize and stop any movement before impact with mechanical stops. 3. During column movement, check for any noise that indicates excessive friction or binding. 7 COMPLETION None Chapter 9 Page no. 1182 JC-DR-A-205.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A206A - Lift Gas Spring Job Card D/R A206A - Lift Gas Spring 1 Chapter 9 SUPPLIES Lift Gas Spring 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 60 minutes 4 SAFETY PRECAUTIONS WARNING The lift gas spring has a larger mechanical energy when the arm is at heights of less than the maximum height. To minimize the risk of rapid gas spring movement due to stored mechanical energy, you must ensure that the Arm is raised to its maximum height before you proceed. WARNING The Gantry must be powered off. 5 • • • • • PREREQUISITES The arm must be in the vertical position. Raise the arm to its maximum height. Switch off the Gantry power. Remove the Front and Column covers for access (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). Release and remove the Gantry curtains (refer to Job Card D/R A208 - Gantry Curtains on page 1193). Page no. 1183 JC-DR-A-206.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A206A - Lift Gas Spring 6 PROCEDURE WARNING Do not touch the piston rod of the gas spring during disassembly (or reassembly). If you crimp the piston rod with the circlip pliers to remove the U-fork then you will damage the surface of the piston rod. 6-1 Disassembly of the Lift Gas Spring To disassemble the Lift Gas Spring (1), proceed as follows: 1. Raise the arm manually until the lift belt is loose: Access the trapezoidal screw (2) on the top right side of the Gantry; use a ratchet handle (13 mm hex socket) to turn it clockwise. 1 2 2. Release the four bolts securing the lower X plate (10 mm open-ended wrench). 3. Use circlip pliers to pull the clip (3), and push the inner pin to free the belt. WARNING Be careful to avoid any slapping effect of the belt when freeing it. 4. Remove the gas spring stirrup at the top (6 mm allen wrench). 3 Chapter 9 Page no. 1184 JC-DR-A-206.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A206A - Lift Gas Spring 5. Remove the gas spring lower shaft: - Remove the roller (4). - Remove the pulley shaft (5). - Remove the gas spring shaft (6). 6 5 4 6. Remove the belt, then pull the gas spring forward. Unscrew it by turning it clockwise. The arm cover may be an obstacle when tilting the gas spring for removal (7). 7 7. Remove the U-fork (8) from the top of the gas spring (10 mm open-ended wrench). 8 Page no. 1185 JC-DR-A-206.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A206A - Lift Gas Spring 6-2 Reassembly of the Lift Gas Spring WARNING • Do not touch the piston rod of the gas spring during reassembly (or disassembly). If you crimp the piston rod with the circlip pliers to replace the U-fork then you will damage the surface of the piston rod. Reverse the disassembly procedure, with the addition of the following steps: 1. Turn the endless screw (2) counter-clockwise (13 mm hex socket) and move the arm down 50 mm to make the belt taut. This places the gas spring under pressure. 2. Assemble the stirrup (upper and lower parts) using M6 screws, but do not tighten them. 3. Adjust the alignment of the gas spring in the front-rear direction (the holes on the stirrup are elongated to allow adjustment). 4. The belt must be positioned in the opening of the fork (9). 5. Tighten the stirrup securing screws. 9 6. Check the distance between the gas spring and the guidance system at the top and bottom of the gas spring. Use vernier calipers to make measurements as shown. The nominal measurement is 143.5 mm (5.65 inches). Chapter 9 Page no. 1186 JC-DR-A-206.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A206A - Lift Gas Spring 6-3 Check the Column Movement 1. Move the compression paddle out of compression. Then check that all four sets of column up/down control buttons are operational (check each button for up and down movement of the column). 2. Move the column to its upper and lower limits. Software limits should stop movement. If the software limits fail, the optical forks are used to recognize and stop any movement before impact with mechanical stops. 3. During column movement, check for any noise that indicates excessive friction or binding. 4. Move the lift over its full stroke 5 times to initiate proper self-greasing of the gas spring. 7 COMPLETION No calibrations are required. Page no. 1187 JC-DR-A-206.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A206A - Lift Gas Spring This page is blank. Chapter 9 Page no. 1188 JC-DR-A-206.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A207 - Lift Belt Job Card D/R A207 - Lift Belt 1 Chapter 9 SUPPLIES Lift Belt 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 60 minutes 4 SAFETY PRECAUTIONS WARNING The lift belt has a larger mechanical energy when the arm is at heights of less than the maximum height. To minimize the risk of rapid lift belt movement due to stored mechanical energy, you must ensure that the Arm is raised to its maximum height before you proceed. WARNING The Gantry must be powered off. 5 PREREQUISITES • Raise the arm to its maximum height. • Switch off the system power. • Remove the Front and Column covers for access to the lift belt (1) (refer to Job Card PHY A044 - Remove/ Reinstall Gantry Covers on page 523). • 1 Loosen and remove the Gantry curtain (refer to Job Card D/R A208 - Gantry Curtains on page 1193). Page no. 1189 JC-DR-A-207.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A207 - Lift Belt 6 PROCEDURE 6-1 Disassembly of the Lift Belt 1. Continue to raise the belt pulley (2) manually (raise the arm) until the lift belt is loosened Access the endless screw (3) on the top right side of the Gantry, use a ratchet handle (13 mm hex socket) and turn clockwise. 2 3 UPPER RIGHT SIDE - LATERAL VIEW UPPER LEFT SIDE - FRONT VIEW 2. Release the four bolts securing the lower X plate (4) (10 mm open-ended wrench). 3. Remove the curtain roller (5). 4 5 Chapter 9 Page no. 1190 JC-DR-A-207.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A207 - Lift Belt 4. Use circlip pliers to pull the clip (6), and push the inner pin to free the belt. 7 WARNING Be careful to avoid any slapping effect of the belt when freeing it. 5. Release the four screws securing the fixing plate (7) (5 mm allen wrench, 8 mm open-ended wrench); remove the fixing plate. 6 6. Release the four screws securing the upper fixing plate (8) (8 mm allen wrench), but do not remove the plate. 7. Release the belt. 8 6-2 Reassembly of the Lift Belt Proceed to the following steps: 1. Insert the lower end of the belt (9) so that it protrudes by 20 mm from the edge of the lower fixing plate (two teeth = 20 mm). 2. Insert the end of the belt at the edge of the upper fixing plate (8). 3. Apply blue Loctite to the threads of the four securing screws (10) before tightening them. 4. Tighten the four screws securing the belt to the upper fixing plate (8) (8 mm allen wrench). 5. Remove the Gas Spring stirrup. Discard it, and use a new one in its place. 6. Turn the endless screw (3) counter-clockwise (13 mm hex socket) and move the arm down 50 mm to tighten the belt. This places the Gas Spring under pressure. 7. Use the four bolts to secure the lower X plate (10 mm openended wrench) to the Gantry framework. Page no. 1191 JC-DR-A-207.fm 10 9 Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A207 - Lift Belt 6-3 Check the Column Movement 1. Move the compression paddle out of compression. Then check that all four sets of column up/down control buttons are operational (check each button for up and down movement of the column). 2. Move column to its upper and lower limits. Software limits should stop movement. If the software limits fail, the optical forks are used to recognize and stop any movement before impact with mechanical stops. 3. During column movement, check for any noise that indicates excessive friction or binding. 7 COMPLETION None Chapter 9 Page no. 1192 JC-DR-A-207.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A208 - Gantry Curtains Job Card D/R A208 - Gantry Curtains 1 Chapter 9 SUPPLIES Kit containing upper and lower Gantry Curtains 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 60 minutes 4 SAFETY PRECAUTIONS WARNING While performing this procedure, you must: Power off the Gantry. Wear safety glasses and gloves. 5 • • • • • PREREQUISITES Switch off the Gantry power. Remove the front and column covers (refer to Job Card PHY A044 Remove/Reinstall Gantry Covers on page 523. Switch on the Gantry power. Use the lift command buttons to move the arm vertically until the two springs (1) are fully visible in the opening at the rear of the column frame. Switch off the Gantry power. Page no. 1193 JC-DR-A-208.fm 1 Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A208 - Gantry Curtains 6 PROCEDURE Note: If you do not wish to replace the curtains, but you need access to a part in the Gantry, you need only follow the steps of section 6-1 as listed here: • Step 1 for access above the Gantry arm (A). • Steps 1 and 2 for access below the Gantry arm (B). • Steps 1, 2, and 3 to access the rear of the Gantry (C). A C B 6-1 Disassembly of the Gantry Curtains 1. Use bent needle-nose pliers to unhook and remove the two springs (2) from the curtains 2 CAUTION If the extremity of the spring slides out of the pliers, the spring can fly out and cause injury. 2. Release and remove the four screws (3) to release the curtains (7 mm open ended wrench). 3. If the curtains are to be replaced or you require access to the rear of the Gantry, slide the curtains out of their rollers. 3 CAUTION Never attempt to remove the screws (3) while the springs are under tension. They can fly out and cause injury. Chapter 9 Page no. 1194 JC-DR-A-208.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A208 - Gantry Curtains 6-2 • 1. 2. 3. 4. Reassembly of the Gantry Curtains To reverse the disassembly procedure, proceed as follows. Slide the upper and lower curtains onto their rollers. Refit the curtain securing screws (3). Hook the lower ends of the springs into the holes in the lower curtain. Hook the upper ends of the springs into the holes in the upper curtain. Use an allen wrench or a plastic cable tie: - To use an allen wrench: Engage the wrench with the spring hook and the hole in the curtain as shown. Lift the wrench to tighten the spring and bring the hook near to the hole. Twist the spring hook so that it enters the hole. Pull out the wrench. - To use a cable tie: Loop the cable tie into the upper spring hook, then use it as a handle to guide the hook into the hole in the curtain. 5. Remove the plastic which protects the new curtains. To avoid the risk of marking the new white curtains with grease or dirt., this must be done as the last step before remounting the column covers. 6. Remount the front and column covers (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. 7 COMPLETION No calibrations are required. Page no. 1195 JC-DR-A-208.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A208 - Gantry Curtains This page is blank. Chapter 9 Page no. 1196 JC-DR-A-208.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A210 - Gantry cover replacement guide Job Card D/R A210 - Gantry cover replacement guide 1 • Chapter 9 COVER REPLACEMENT Because the design of the Senographe system has evolved since its introduction, some cover panels supplied as replacement items are not directly compatible with earlier models. If you need to change a cover on some earlier models, it may therefore be necessary to order and install a set of covers. In some cases a modification may be required before the replacement covers can be installed. When changing covers, new screw head cover caps are usually required. A kit of screws and caps is available; it provides screw caps and a selection of screws, nuts, and washers to replace lost items. This Job Card provides a guide to cover compatibility, and lists the parts required for replacement of any cover. • • • 2 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 37 minutes 3 PROCEDURE 3-1 System Cover Overview Use this illustration to identify the main groups of covers: Column covers Head covers Compression covers Arm covers Detector covers 3-2 • • Finding cover replacement information First remove the defective cover(s). Note the part number reference (PI) of each part to be changed. Page no. 1197 JC-DR-A-210.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A210 - Gantry cover replacement guide • • Identify each of these parts in the following summary table. The table gives the locations of part replacement information in this Job Card. If you cannot find a reference number on the cover, use the number given in section 4 page 1213. TABLE 1 - COVER REPLACEMENT SUMMARY Reference no. 2375024 Detector Cover Upper For replacement, see: section 3-7-1 page 1209 2375024-2 section 3-7-2 page 1209 2375024-3 section 3-7-1 page 1209 2375025 Detector Cover Lower section 3-7-1 page 1209 2375025-2 section 3-7-2 page 1209 2375025-3 section 3-7-1 page 1209 2375027 Column Cover Top Left section 3-3-1 page 1201 2375027-2 section 3-3-2 page 1201 2375027-3 section 3-3-1 page 1201 2375028 Column Cover Top Right section 3-3-1 page 1201 2375028-2 section 3-3-2 page 1201 2375028-3 section 3-3-1 page 1201 2375029 Column Cable Exit section 3-3-1 page 1201 2375029-2 section 3-3-2 page 1201 2375029-3 section 3-3-1 page 1201 2375030 Column Cover Bottom Front section 3-3-1 page 1201 2375030-2 section 3-3-2 page 1201 2375030-3 section 3-3-1 page 1201 2375031 Column Cover Bottom Rear section 3-3-1 page 1201 2375031-2 section 3-3-2 page 1201 2375031-3 section 3-3-1 page 1201 2375032 Column Cover Front Left section 3-3-1 page 1201 2375032-2 section 3-3-2 page 1201 2375032-3 section 3-3-1 page 1201 2375033 Column Cover Front Right section 3-3-1 page 1201 2375033-2 section 3-3-2 page 1201 2375033-3 section 3-3-1 page 1201 2375037 Arm Cover Left section 3-4-1 page 1203 2375037-2 section 3-4-2 page 1203 2375037-3 section 3-4-1 page 1203 2375037-4 section 3-4-2 page 1203 2375038 Chapter 9 Description Arm Cover Right section 3-4-1 page 1203 2375038-2 section 3-4-2 page 1203 2375038-3 section 3-4-1 page 1203 2375038-4 section 3-4-2 page 1203 Page no. 1198 JC-DR-A-210.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A210 - Gantry cover replacement guide Reference no. 2375040 Description Compression Cover Upper 2375040-3 2375041 Compression Cover Lower section 3-5-1 page 1205 section 3-5-1 page 1205 Head Cover Left section 3-6-1 page 1207 2375043-2 section 3-6-2 page 1207 2375043-3 section 3-6-1 page 1207 2375044 Head Cover Right section 3-6-1 page 1207 2375044-2 section 3-6-2 page 1207 2375044-3 section 3-6-1 page 1207 2401145-2 Compression Cover Upper section 3-5-2 page 1205 2401147 Compression Cover Lower section 3-5-2 page 1205 Page no. 1199 JC-DR-A-210.fm section 3-5-1 page 1205 section 3-5-1 page 1205 2375041-3 2375043 For replacement, see: Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A210 - Gantry cover replacement guide 3-3 • • • Column Covers Refer to section 3-3-1 page 1201 and section 3-3-2 page 1201 to determine if the defective cover(s) can be replaced individually, or if a complete set must be ordered and installed. Order and install the specified parts. Use a copy of the table given in Order Summary on page 1214 to list the parts to be ordered. After installing the new covers, verify that the positioner reaches rotation and angulation limit positions correctly, and that no cable is twisted or under excessive strain. Column Cover Top Left Column Cover Top Right Column Cover Front Left Column Cover Front Right Column Cover Bottom Rear Column Cover Bottom Front Chapter 9 Page no. 1200 JC-DR-A-210.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A210 - Gantry cover replacement guide 3-3-1 Column Covers - non-available covers • If the reference of the defective part appears in the following table, it cannot be replaced individually. A complete set of covers must be ordered and installed: Reference - Description 2375027 2375027-3 Column Cover Top Left 2375028 2375028-3 Column Cover Top Right 2375029 2375029-3 Column Cover Cable Exit 2375030 2375030-3 Column Cover Bottom Front 2375031 2375031-3 Column Cover Bottom Back 2375032 2375032-3 Column Cover Front Left 2375033 2375033-3 Column Cover Front Right Order a set of covers as listed below: Reference Description Quantity 2375027-2 Column Cover Top Left 1 2375028-2 Column Cover Top Right 1 2375029-2 Column Cover Cable Exit 1 2375030-2 Column Cover Bottom Front 1 2375031-2 Column Cover Bottom Back 1 2375032-2 Column Cover Front Left 1 2375033-2 Column Cover Front Right 1 5130589 Kit of screws and caps for covers 1 - Install the new covers using the information given in Job Card PHY A044 - Remove/Reinstall Gantry Covers, section 7 page 524. 3-3-2 Column Covers - available covers • If the reference of the defective part appears in the following table, it can be replaced individually. The table indicates the necessary part(s) to be ordered. Order the following parts: If the defective part is: Reference Description Quantity 2375027-2 Column Cover Top Left 2375027-2 Column Cover Top Left 1 2375028-2 Column Cover Top Right 2375028-2 Column Cover Top Right 1 2375029-2 Column Cover Cable Exit 2375029-2 Column Cover Cable Exit 1 2375030-2 Column Cover Bottom Front 2375030-2 Column Cover Bottom Front 1 2375031-2 Column Cover Bottom Back 2375031-2 Column Cover Bottom Back 1 2375032-2 Column Cover Front Left 2375032-2 Column Cover Front Left 1 2375033-2 Column Cover Front Right 2375033-2 Column Cover Front Right 1 Kit of screws and caps for covers 1 Order also: - 5130589 Install the new cover(s) using the information given in Job Card PHY A044 - Remove/Reinstall Gantry Covers, section 7 page 524. Page no. 1201 JC-DR-A-210.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A210 - Gantry cover replacement guide 3-4 • • • Arm Covers Refer to section 3-4-1 page 1203 and section 3-4-2 page 1203 to determine if the defective cover(s) can be replaced individually, or if a complete set must be ordered and installed. Order and install the specified parts. Use a copy of the table given in Order Summary on page 1214 to list the parts to be ordered. After installing the new covers, verify that the positioner reaches rotation and angulation limit positions correctly, and that no cable is twisted or under excessive strain. Arm Cover Left Arm Cover Right Chapter 9 Page no. 1202 JC-DR-A-210.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A210 - Gantry cover replacement guide 3-4-1 Arm Covers - non-available covers • If the reference of the defective part appears in the following table, it cannot be replaced individually. A complete set of covers must be ordered and installed: Reference - Description 2375037 2375037-3 Arm Cover Left 2375038 2375038-3 Arm Cover Right Order a set of covers as listed below: Reference Description Quantity 2375037-4 Arm Cover Left 1 2375038-4 Arm Cover Right 1 2412297 Arm Cover Rework Assy 1 2401145-2 Compression Cover Upper 1 2401147 Compression Cover Lower 1 2375043-2 Head Cover Left 1 2375044-2 Head Cover Right 1 2399858-2 GE Logo D60 1 5130589 Kit of screws and caps for covers 1 2352894-2 Handle assembly 1 - Refer to section 3-8 page 1210 to install the Arm Cover Rework Assembly. After installation of the Arm Cover Rework Assembly, install the new covers using the information given in Job Card PHY A044 - Remove/Reinstall Gantry Covers, section 8 page 526. 3-4-2 Arm Covers - available covers • If the reference of the defective part appears in the following table, it can be replaced individually. The table indicates the necessary part(s) to be ordered. If the defective part is: Reference Description Quantity 2375037-2 Arm Cover Left 2375037-4 Arm Cover Left 1 2375038-2 Arm Cover Right 2375038-4 Arm Cover Right 1 2375037-4 Arm Cover Left 2375037-4 Arm Cover Left 1 2375038-4 Arm Cover Right 2375038-4 Arm Cover Right 1 5130589 Kit of screws and caps for covers 1 Order also: 3-4-3 • Order the following parts: Install the new cover(s) using the information given in Job Card PHY A044 - Remove/Reinstall Gantry Covers, section 8 page 526. Post -installation checks After installing the new covers, verify that the positioner reaches rotation and angulation limit positions correctly, and that no cable is twisted or under excessive strain. Page no. 1203 JC-DR-A-210.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A210 - Gantry cover replacement guide 3-5 • • • Compression Covers Refer to section 3-5-1 page 1205 and section 3-5-2 page 1205 to determine if the defective cover(s) can be replaced individually, or if a complete set must be ordered and installed. Order and install the specified parts. Use a copy of the table given in Order Summary on page 1214 to list the parts to be ordered. After installing the new covers, verify that the positioner reaches rotation and angulation limit positions correctly, and that no cable is twisted or under excessive strain. Compression Cover Upper Compression Cover Lower Chapter 9 Page no. 1204 JC-DR-A-210.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A210 - Gantry cover replacement guide 3-5-1 Compression Covers - non-available covers • If the reference of the defective part appears in the following table, it cannot be replaced individually. A complete set of covers must be ordered and installed: Reference of defective part - • • Description 2375040 2375040-3 2401145 Compression Cover Upper 2375041 2375041-3 Compression Cover Lower Order a set of covers as listed below: Reference Description Quantity 2375037-4 Arm Cover Left 1 2375038-4 Arm Cover Right 1 2412297 Arm Cover Rework Assy 1 2401145-2 Compression Cover Upper 1 2401147 Compression Cover Lower 1 2375043-2 Head Cover Left 1 2375044-2 Head Cover Right 1 2399858-2 GE Logo D60 1 5130589 Kit of screws and caps for covers 1 2352894-2 Handle assembly 1 Refer to section 3-8 page 1210 to install the Arm Cover Rework Assembly. After installation of the Arm Cover Rework Assembly, install the new covers using the information given in Job Card PHY A044 - Remove/Reinstall Gantry Covers, section 8 page 526. Note that for the installation of arm covers, you need to consider the case “flexible covers”. • 3-5-2 Compression Covers - available covers • If the reference of the defective part appears in the following table, it can be replaced individually. The table indicates the necessary part(s) to be ordered Order the following parts: If the defective part is: Description Quantity 2401145-2 Compression Cover Upper 2401145-2 Compression Cover Upper 1 2401147 Compression Cover Lower 2401147 Compression Cover Lower 1 5130589 Kit of screws and caps for covers 1 Order also: • Reference Install the new cover(s) using the information given in Job Card PHY A044 - Remove/Reinstall Gantry Covers, section 8 page 526. Page no. 1205 JC-DR-A-210.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A210 - Gantry cover replacement guide 3-6 • • • Head Covers Refer to section 3-6-1 page 1207 and section 3-6-2 page 1207 to determine if the defective cover(s) can be replaced individually, or if a complete set must be ordered and installed. Order and install the specified parts. Use a copy of the table given in Order Summary on page 1214 to list the parts to be ordered. After installing the new covers, verify that the positioner reaches rotation and angulation limit positions correctly, and that no cable is twisted or under excessive strain. Head Cover Left Head Cover Right Chapter 9 Page no. 1206 JC-DR-A-210.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A210 - Gantry cover replacement guide 3-6-1 Head Covers - non-available covers • If the reference of the defective part appears in the following table, it cannot be replaced individually. A complete set of covers must be ordered and installed: Reference of defective part - • • Description 2375043 2375043-3 Head Cover Left 2375044 2375044-3 Head Cover Right Order a set of covers as listed below: Reference Description Quantity 2375037-4 Arm Cover Left 1 2375038-4 Arm Cover Right 1 2412297 Arm Cover Rework Assy 1 2401145-2 Compression Cover Upper 1 2401147 Compression Cover Lower 1 2375043-2 Head Cover Left 1 2375044-2 Head Cover Right 1 2399858-2 GE Logo D60 1 5130589 Kit of screws and caps for covers 1 2352894-2 Handle assembly 1 Refer to section 3-8 page 1210 to install the Arm Cover Rework Assembly. After installation of the Arm Cover Rework Assembly, install the new covers using the information given in Job Card PHY A044 - Remove/Reinstall Gantry Covers, section 9 page 529. Note that for the installation of arm covers, you need to consider the case “flexible covers”. 3-6-2 Head Covers - available covers • If the reference of the defective part appears in the following table, it can be replaced individually. The table indicates the necessary parts to be ordered Order the following parts: If the defective part is: Description Quantity 2375043-2 Head Cover Left 2375043-2 Head Cover Left 1 2375044-2 Head Cover Right 2375044-2 Head Cover Right 1 5130589 Kit of screws and caps for covers 1 Order also: • Reference Install the new cover(s) using the information given in Job Card PHY A044 - Remove/Reinstall Gantry Covers, section 9 page 529. Page no. 1207 JC-DR-A-210.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A210 - Gantry cover replacement guide 3-7 • • • Detector Covers Refer to section 3-7-1 page 1209 and section 3-7-2 page 1209 to determine if the defective cover(s) can be replaced individually, or if a complete set must be ordered and installed. Order and install the specified parts. Use a copy of the table given in Order Summary on page 1214 to list the parts to be ordered. After installing the new covers, verify that the positioner reaches rotation and angulation limit positions correctly, and that no cable is twisted or under excessive strain. Detector Cover Upper Detector Cover Lower Chapter 9 Page no. 1208 JC-DR-A-210.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A210 - Gantry cover replacement guide 3-7-1 Detector Covers - non-available covers • If the reference of the defective part appears in the following table, it cannot be replaced individually. A complete set of covers must be ordered and installed: Reference - Description 2375024 2375024-3 Detector Cover Upper 2375025 2375025-3 Detector Cover Lower Order a set of covers as listed below: Reference Description Quantity 2375024-2 Detector Cover Upper 1 2375025-2 Detector Cover Lower 1 2411952 Quick Fix Assy for Detector Covers 1 2408213 Interface Plate Equipped 1 • • The Detector must be modified to accept the new covers. Refer to section 3-9 page 1211. The new Detector/Positioner Interface Plate reference 2408213, together with the new Quick Fix Assembly, reference 2411952, must be installed in place of the existing Interface Plate. Refer to section 3-10 page 1212. • After modifying the detector and changing the interface plate, install the new covers using the information given in Job Card PHY A044 - Remove/Reinstall Gantry Covers, section 10 page 530. 3-7-2 Detector Covers - available covers If the reference of the defective part appears in the following table, it can be replaced individually. The table indicates the necessary part(s) to be ordered Order the following parts: If the defective part is: • Reference Description Quantity 2375024-2 Detector Cover Upper 2375024-2 Detector Cover Upper 1 2375025-2 Detector Cover Lower 2375025-2 Detector Cover Lower 1 Install the new cover(s) using the information given in Job Card PHY A044 - Remove/Reinstall Gantry Covers, section 10 page 530. Page no. 1209 JC-DR-A-210.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A210 - Gantry cover replacement guide 3-8 • • Installation of the Arm Cover Rework Assembly The Arm Cover Rework Assembly must be installed on earlier systems to provide anchor points for newer covers. Install the assembly as described below: B A D E C 1. - Screw the provided locking nut (A) onto the threaded rod (B) of the Arm Cover Rework Assy. 2. - Fit the rod into the lowest pair of holes in the Arm Beam (C). 3. - Screw the two tapped fittings (D, E) onto the ends of the rod to secure it, and use the locking nut to lock one of them in place. 4. - Use the two M4 screws provided to secure the Arm covers to the two tapped fittings, one each side. Chapter 9 Page no. 1210 JC-DR-A-210.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A210 - Gantry cover replacement guide 3-9 Detector rework Securing holes must be added to the Detector assembly on earlier systems to provide anchor points for the newer covers. 1. Remove the Detector by following the instructions of Job Card D/R A141 - Image Receptor/Digital Detector on page 1099. 2. Drill a 4 mm countersink hole at 90° to the exterior face through the mounting lug on each side of the assembly: - Position; 16.7 mm behind the existing hole, as shown below. - Diameter: 4 ±0,1mm. - Countersink to 7±0,5 mm on the exterior face. 16.7 mm Page no. 1211 JC-DR-A-210.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A210 - Gantry cover replacement guide 3-10 mounting of the Interface Plate and Quick Fix Cover Detector Cover Upper Detector B A C Detector Cover Lower 3-10-1 Installation of the Interface Plate and Cover Fix plates 1. Remove the Detector by following the instructions of Job Card D/R A141 - Image Receptor/Digital Detector on page 1099. 2. Remove the metal sheet at the bottom of the detector/positioner Interface Plate, where the detector cables are attached. 3. Remove the existing detector/positioner Interface Plate 4. Install the new Interface Plate (A) provided in the kit. 5. Reinstall the metal sheet at the bottom of the detector/positioner Interface Plate. 6. Reinstall the detector by following the instructions of Job Card D/R A141 - Image Receptor/Digital Detector on page 1099. 7. Secure the Cover Fix Right (B) to the Interface Plate using two M4 screws. 8. Secure the Cover Fix Left (C) to the Interface Plate using two M4 screws. Chapter 9 Page no. 1212 JC-DR-A-210.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A210 - Gantry cover replacement guide 4 REPLACEMENT OF COVERS WITH NO REFERENCE NUMBER If you cannot find a reference number on the defective cover, you may be working with an early machine. Use the following table to determine the number: Column Cover Top Left 2375027 Column Cover Top Right 2375028 Column Cable Exit 2375029 Column Cover Bottom Front 2375030 Column Cover Bottom Back 2375031 Column Cover Front Left 2375032 Column Cover Front Right 2375033 Arm Cover Left 2375037 Arm Cover Right 2375038 Compression Cover Upper 2375040 Compression Cover Lower 2375041 Head Cover Left 2375043 Head Cover Right 2375044 Detector Cover Upper 2375024 Detector Cover Lower 2375025 Page no. 1213 JC-DR-A-210.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A210 - Gantry cover replacement guide 5 • • ORDER SUMMARY Use a copy of this table to enter the required quantities of parts to be ordered. The quantity to order for each cover is either 1 or 0. . Reference Description Quantity? 2375027-2 Column Cover Top Left 1 0 2375028-2 Column Cover Top Right 1 0 2375030-2 Column Cover Bottom Back 1 0 2375031-2 Column Cover Bottom Front 1 0 2375032-2 Column Cover Front Left 1 0 2375033-2 Column Cover Front Right 1 0 2375037-4 Arm Cover Left 1 0 2375038-4 Arm Cover Right 1 0 2412297 Arm Cover Rework Assy 1 0 2401145-2 Compression Cover Upper 1 0 2401147 Compression Cover Lower 1 0 2375043-2 Head Cover Left 1 0 2375044-2 Head Cover Right 1 0 2399858-2 GE Logo D60 1 0 2352894-2 Handle assembly 1 0 2375024-2 Detector Cover Upper 1 0 2375025-2 Detector Cover Lower 1 0 2411952 Quick Fix Assy for Detector Covers 1 0 2408213 Interface Plate Equipped 1 0 5130589 Kit of screws and caps for covers 1 0 Note: In addition to screws and washers, the Kit of screws and caps for covers, part number 5130589, includes 14 White caps, p/n 45559940, and 12 Caps, p/n 2401735. This is sufficient for the installation of any of the sets of covers described in this document. If you are replacing two or three covers it is usually only necessary to order one kit. Chapter 9 Page no. 1214 JC-DR-A-210.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A212 - Gantry Readout Job Card D/R A212 - Gantry Readout 1 Chapter 9 SUPPLIES Gantry Readout (LCD panel) 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 PREREQUISITES • Switch off the Gantry power. • Remove the front covers, the column covers, and the bottom front cover (2) (refer to Job Card PHY A044 - Remove/ Reinstall Gantry Covers on page 523) for access to the Gantry Readout (1). 6 PROCEDURE 6-1 Disassembly of the Gantry Readout 1 2 1. Disconnect the LCD connect cable (W204) from the Lift Board (connector J15). 2. Carefully remove the LCD connect cable through the column. 3. Remove the four screws securing the Gantry Readout (screwdriver). 4. Remove the Gantry Readout. 6-2 Reassembly of the Gantry Readout Reverse the disassembly procedure. Page no. 1215 JC-DR-A-212.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A212 - Gantry Readout 6-3 Check Gantry Readout Cable Position If the Gantry Readout ribbon cable is long, then: • Ensure that the Gantry Readout ribbon cable passes from the Lift Board to the Gantry Readout by the shortest route, and is not allowed to pass near the lift motor. • With a cabletie, gently loop the ribbon cable so that the loop is 10 cm wide, and so that 13 cm is free after the loop so that the ribbon cable can be connected to the Lift Board. • Ensure that the loop that you created sits firmly on the base of the Gantry at 13 cm away from the Lift Board as shown below: If you do not check the positioning of the Gantry Readout ribbon cable, there is a risk of EMC interference between the Lift Board and ribbon cable. This EMC interference can cause the Gantry Readout to appear corrupted as shown below. Corrupted Gantry Readout display due to bad positioning of Gantry Readout ribbon cable with respect to Lift Board. 7 COMPLETION Check that the Gantry Readout is functioning correctly. The LCD in the Gantry Readout contains Mercury, therefore properly dispose of the Gantry Readout in accordance to your local laws. Chapter 9 Page no. 1216 JC-DR-A-212.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A215 - Arm Control Keypad Cables Job Card D/R A215 - Arm Control Keypad Cables 1 Chapter 9 SUPPLIES Replacement cables as required: • Cable W407 for arm control keypads on the Tube Head. • Cable W305 for arm control keypads on the Arm. 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 PREREQUISITES None 6 PROCEDURE 6-1 Removal and Reinstallation of Cables from the Tube Head Keypads 1. 2. 3. 4. 5. 6. Switch off all Senographe electrical power. Remove the tube head covers (see Tube Head Covers on page 529). Disconnect the keypad cable from the keypad and from connector J7 or J8 on the Tilt Board PL401. Remove the cable. Install the replacement cable. Ensure that the keypad cables are positioned as shown: Cable from left keypad passes beneath the HV cable to connect to J8 Cable from right keypad connects to J7 View on Tilt Board looking towards the tube. Arm turned 90° to the right. Page no. 1217 JC-DR-A-215.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A215 - Arm Control Keypad Cables 6-2 Removal and Reinstallation of Cables from the Arm Keypads 1. Switch off all Senographe electrical power. 2. Remove the Arm covers (see Arm Covers and Handle on page 526). 3. Disconnect the keypad cable from the keypad and from connector J7 or J8 on the Compression Board PL303. 4. Remove the cable. 5. Install the replacement cable. 6. Ensure that the keypad cables are positioned as shown: Cable from right keypad is secured to the Arm Distribution Board spacer as shown. Keypad cables are connected to the Compression Board. Cable from left keypad Cable from right keypad View from right, arm at 0°. 7 View from left, arm at 0°. COMPLETION Check for correct operation of all keypad controls. Chapter 9 Page no. 1218 JC-DR-A-215.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A216 - Arm Control Keypads Job Card D/R A216 - Arm Control Keypads 1 Chapter 9 SUPPLIES Replacement keypads (5268425-2) as required (see below). CAUTION Older keypads PN 2383315 and PN 2383315-2 must not be reused. Always use V2 keypads (PN 5268425-2). The V2 Keypads (PN 5268425-2) have a membrane switch below the surface of the lift and rotation buttons to securitize the movement. The result is the surface of the lift and rotation buttons are flexible, and that movement is not possible if you press on the far edge of the lift/rotation buttons. Pairs of Keypads (on the Tube Head or Arm) must be matched with the same version of Keypad on each side of the Tube Head or Arm. Use the following steps to determine whether you need to order one or two V2 keypads: 1. Firmly press your finger on the middle of the Keypad lift/rotation button as shown below to observe whether the button contains a membrane. V1 V2 Indentation of membrane 2. On a working Keypad, press the far edge of the lift/rotation button, and observe if there is lift/rotation movement. Far edge of button • If there is lift/rotation movement, the currently installed Keypad is an old V1 Keypad. • If there is no lift/rotation movement, the currently installed Keypad is a new V2 Keypad. 3. Pairs of Keypads (either on the Tube Head or Arm) must be matched with the same version of Keypad on each side of the Tube Head or Arm. Order replacement V2 Keypads according to the following table. Is the surface of the lift/ rotation button flexible? Is there movement when pressing the extreme edge of the lift/ rotation button? Number of V2 Keypads (PN 5268425-2) to order Yes No One to replace the faulty V2 Keypad. No Yes Two - one to replace the faulty V1 Keypad, and the second to replace the other working V1 Keypad so that there is a matching pair of V2 Keypads. Page no. 1219 JC-DR-A-216.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A216 - Arm Control Keypads 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 PREREQUISITES 1. Switch off all Senographe electrical power. 2. Prepare a suitable working surface, with protection to avoid scratching the covers. 6 PROCEDURE ! Notice: Wear an ESD protection strap when removing and replacing keypads. When removing a cover with its keypad, take care to move it slowly from the structure, to avoid damage to cables and connectors. 6-1 Removal of Keypads For each keypad to be removed: 1. Remove the cover which carries the keypad (see Arm Covers and Handle on page 526 or Tube Head Covers on page 529). 2. Disconnect the keypad cable from the keypad; leave it connected at the Compression Board PL303 or the Tilt Board PL401. 3. Place the cover on the prepared working surface. 4. Check the condition of the cable (W305 or W407). If there is any sign of damage or pinching, a new cable must be fitted (see Job Card D/R A215 - Arm Control Keypad Cables on page 1217). 5. Remove and keep for reuse the nuts and washers (three sets) which secure the keypad (ratchet wrench with 11 mm socket (Arm covers) or 6 mm socket (Head covers)). 6. Remove the keypad from the cover. 6-2 Installation of Replacement Keypads For each keypad to be installed: 1. Remove the keypad from its ESD protective envelope and position it on the cover locating pins. 2. Applying light pressure only, use three sets of nuts and washers to secure the keypad (ratchet wrench with 11 mm socket (Arm covers) or 6 mm socket (Head covers)). 3. On the external side of the cover, check that the keypad is correctly centered in its opening. If necessary adjust the position. 4. For each button in turn, check that there is no contact with the cover opening when the button is fully depressed. Chapter 9 Page no. 1220 JC-DR-A-216.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A216 - Arm Control Keypads 5. For each of the three securing nuts in turn (ratchet wrench with 11 mm socket (Arm covers) or 6 mm socket (Head covers)): - Remove the nut. Apply some thread locking compound (Loctite 243 or equivalent) to the threaded pin. - Refit the nut and tighten it using finger pressure. When correctly secured, the elastomer surface of the keypad must remain in full contact with the inner side of the cover when buttons are pressed, but there must be no deformation of the elastomer. ! Notice: When the keypad is correctly fitted, the rear side of the keypad (black magnetic surface) must be flat. Any deformation of the keypad board can cause damage. 6. When the installation of the keypads on the covers is complete, fit the covers in place temporarily on the Tube Head and/or Arm. This allows the functional checks of keypad operation to be made before completion. For example, install only the minimum number of securing screws required to ensure that covers do not fall, and use masking tape to prevent unwanted movement. ! Notice: 1. Apply only moderate pressure when connecting a cable to a keypad, to avoid damage to the connector. The connector is soldered in its position at right angles to the keypad board surface. 2. When reconnecting keypad cables and installing covers, ensure that the cables are correctly positioned as described in Job Card D/R A215 - Arm Control Keypad Cables on page 1217. 7. With the compression paddle out of compression, check that all four arm rotation control buttons are operational. For each button, check that light or firm pressure gives the correct rotation, and that rotation stops when the pressure is released. Refer to Job Card ELE A015 - Gantry Functional Checks, section 6-4 Keypad Functional Checks on page 580, for a full list of these checks. 7 COMPLETION When all functional checks have been completed successfully, complete the installation of the covers. (see Arm Covers and Handle on page 526 or Tube Head Covers on page 529). Page no. 1221 JC-DR-A-216.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A216 - Arm Control Keypads This page is blank. Chapter 9 Page no. 1222 JC-DR-A-216.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A221 - Rotation Board Job Card D/R A221 - Rotation Board 1 Chapter 9 SUPPLIES Rotation Board 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 90 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 PREREQUISITES • Switch off the Gantry power. • Remove the front covers (Refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). • Loosen and remove the Gantry curtain (Refer to Job Card D/R A208 - Gantry Curtains on page 1193) to access the Rotation Board (1). 1 Page no. 1223 JC-DR-A-221.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A221 - Rotation Board 6 PROCEDURE 6-1 Disassembly of the Rotation Board 1. Release and remove the six screws (2) securing the rotation board protection plate (3) (2 mm allen wrench). 2 3 2. Disconnect all cables from the Rotation Board (4). 3. Remove the six hex nuts (2) securing the rotation board (5.5 mm open-ended wrench) 4. Remove the Rotation Board. 4 6-2 Reassembly of the Rotation Board • Reverse the disassembly procedure. Add the following step to the reassembly procedure: - Apply blue Loctite on the threads of the six screws securing the rotation board supporting plate and tighten them with the Torque wrench (0.8 Nm +/- 0.1 Nm). CAUTION When reconnecting the cables to the Rotation Board, ensure that you route the W215 cable so it does not pass over Rotation Board. This precaution avoids potential interference caused by component electronic noise. Chapter 9 Page no. 1224 JC-DR-A-221.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A221 - Rotation Board 7 COMPLETION 7-1 Firmware Check Check whether the new Rotation Board firmware needs to be updated, as follows: 1. Reboot the Senographe system. 2. Go to the Service Desktop home page (see Launching the Service Desktop on page 120). 3. Consult Table 1 on page 63 in the section Component FW/SW to ADS Version compatibility Matrix on page 63. Determine the system level from the ADS/IDC/Generator CPU versions displayed on the Service Desktop home page, and by consulting Table 1 on page 63. The system level will be defined by one of the System Level (Model Number) columns in Table 1 on page 63. 4. Check whether the current firmware version(s) for the new Rotation Board corresponds to the required firmware version for the that system level. • If the current firmware version(s) match the required version(s) quoted in Table 1 on page 63, no additional steps are required. • If the current firmware version(s) does not match the required version(s), you must perform a firmware update of the mismatched firmware version(s) so that the new Rotation Board firmware version(s) match those quoted in Table 1 on page 63. To update the new Rotation Board firmware follow the instructions supplied in the Gantry Software Update CD-ROM that is kept with the system. 7-2 Calibrations Carry out the calibration procedure: Job Card CAL A021 - Arm Rotation Calibration on page 1679. 7-3 Check Rotation Movement 1. Move the compression paddle out of compression. Check that all four sets of arm left/right control buttons are operational (check each button for rotation movement of column). 2. Rotate column to its left and right limits. Software preset limits must stop movement (185° counterclockwise, 165° clockwise). Page no. 1225 JC-DR-A-221.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A221 - Rotation Board This page is blank. Chapter 9 Page no. 1226 JC-DR-A-221.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A222 - Clutch and Cable Job Card D/R A222 - Clutch and Cable 1 Chapter 9 SUPPLIES Depending on your system configuration: Clutch (2345968-4) or Spare Part Kit Clutch 2345968-4 and Rotation Board 2375488-13 (5265895-2) Note: The FRU Spare Part Kit Clutch 2345968-4 and Rotation Board 2375488-13 (5265895-2) comprises a V2 Clutch (2345968-4) and Rotation Board (2375488-13). V2 Clutches are only phsically compatible with newer V2 Rotation Boards 2375488-12 and above. The first V2 Rotation Boards (2375488-12) were introduced at IS4-3 Forward Production (system model number 2383168-5). To determine whether the Gantry already has a compatible V2 Rotation Board that supports the V2 Clutch, check the model number of the system(located on the Generator covers identification labels). • If the system model number is 2383168-5 or greater, the Gantry contains a V2 Rotation Board. In this case, order the Clutch (2345968-4) and change the Clutch according to the instructions in this Job Card. • If the system model number is 2383168-4-1 or lower, the Gantry does not contain a V2 Rotation Board. In this case, order the Spare Part Kit Clutch 2345968-4 and Rotation Board 2375488-13 (5265895-2). Change the Clutch according to the instructions in this Job Card and also change the Rotation Board (2375488-13) supplied with the kit. For more information on changing the Rotation Board, refer to Job Card D/R A221 - Rotation Board on page 1223. 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 60 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. Page no. 1227 JC-DR-A-222.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A222 - Clutch and Cable 5 PREREQUISITES • Switch off the Gantry power. • Remove the arm and the front covers (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523) for access to the clutch (1). • Loosen and remove the Gantry curtain (refer to Job Card D/R A208 - Gantry Curtains on page 1193) for access to the rotation board. 1 6 PROCEDURE 6-1 Disassembly of the Clutch 1. Unplug the clutch cables W218 and W221 from the Rotation Board (connector J8 and J7). 2. Release and remove the two screws (2) securing the clutch (4 mm allen wrench). 3. Remove the ring supporting the clutch (one screw 5 mm allen wrench). Chapter 9 2 Page no. 1228 JC-DR-A-222.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A222 - Clutch and Cable 6-2 Reassembly of the Clutch 1. Attach the supporting ring to the new clutch (one screw - 5 mm allen wrench). 2. Position the new clutch so that the gap between the plastic on the side of the detector and the clutch is 2 mm. Refer to illustration opposite. Use a 2 mm gauge (2 mm allen wrench or suitable feeler gauge) to ensure that the gap 2 mm(-0 mm, +0.3 mm). 3. Apply blue Loctite 243 on the threads of the two screws that secure the clutch. Then tighten the two screws (2) to secure the clutch to the Arm (4 mm allen wrench). 4. Reconnect the clutch cables of the new clutch to the Rotation Board connectors, as follows: • W218 cable to J8 connector • W221 cable to J7 connector 6-3 Detector Plastic Clutch Arm Allen key or gauge 2 mm gap required Check Cable Positioning Ensure that the clutch cables are correctly positioned, and secured to the spacer of Rotation Board PL202 by a cable tie as shown:. Page no. 1229 JC-DR-A-222.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A222 - Clutch and Cable The cables from the clutch to the Rotation Board PL202 must be secured as shown: Use a cable tie (B) to secure the cables at this point. Pass a cable tie (A) through the hole in the curtain metal support to secure the cables behind the curtain. The free length between the two cable ties (A and B) is approx. 60 cm (24 inch). Use some adhesive tape to secure the two cables together in this area. Do not use cable ties; they can catch on other items during movement. 6-4 When installing the covers, place these cables inside the lower cover with the keypad cable. The cables must move freely; check that they cannot catch on anything. Check Rotation Movement Move the compression paddle out of compression. Then check that all four sets of keypad control buttons on the arm and the tube head are operational (check each button for arm rotation movement). 7 COMPLETION None Chapter 9 Page no. 1230 JC-DR-A-222.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A223 - Rotation Optical Fork Job Card D/R A223 - Rotation Optical Fork 1 Chapter 9 SUPPLIES Rotation Optical Fork 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 75 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 PREREQUISITES • Switch off the Gantry power. • Remove the front covers (Refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). • Loosen and remove the Gantry curtain (refer to Job Card D/R A208 - Gantry Curtains on page 1193) to access the Optical Fork (1). 1 Page no. 1231 JC-DR-A-223.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A223 - Rotation Optical Fork 6 PROCEDURE 6-1 Disassembly of the Optical Fork 1. Release the four bolts securing the lower X plate (10 mm open-ended wrench). 2. Remove the Rotation Board supporting plate 2 3 (3) (3 mm allen wrench). 3. Disconnect the rotation potentiometer cable (2). 4. Open the cable chain to be able to rotate the rotation board. 5. Remove the two screws securing the optical Fork (2.5 mm allen wrench). 6. Unplug the Optical Fork cable (4). 7. Remove the Optical Fork. Chapter 9 4 Page no. 1232 JC-DR-A-223.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A223 - Rotation Optical Fork 6-2 Reassembly of the Optical Fork • Reverse the disassembly procedure. Add the following step to the reassembly procedure: • Apply blue Loctite on the threads of the four screws securing the rotation board supporting plate and on the threads of the two screws securing the Optical Fork before tightening them. CAUTION When connecting the new Optical Fork to the Rotation Board, ensure that you route the W215 cable so it does not pass over Rotation Board. This precaution avoids potential interference caused by component electronic noise. 6-3 Check the Rotation Movement 1. Move the compression paddle out of compression. Then check that all four sets of arm left/right control buttons are operational (check each button for rotation movement of column). 2. Move column to its left and right limits. Software preset limits should stop movement (185° counterclockwise, 165° clockwise). 7 COMPLETION None Page no. 1233 JC-DR-A-223.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A223 - Rotation Optical Fork This page is blank. Chapter 9 Page no. 1234 JC-DR-A-223.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A224 - Gas Spring for Rotation Worm Gear Job Card D/R A224 - Gas Spring for Rotation Worm Gear 1 Chapter 9 SUPPLIES Gas Spring for Rotation Worm Gear-100N 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 60 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 • • PREREQUISITES Remove the front covers (refer to Job Card PHY A044 Remove/Reinstall Gantry Covers on page 523). Raise the arm until the mounting plate of the Gas Spring rises above the pulley of lift belt. 1 • • Rotate the arm to about 45 degrees clockwise from vertical for good access to the housing of the Gas Spring (1) Switch off the Gantry power. Page no. 1235 JC-DR-A-224.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A224 - Gas Spring for Rotation Worm Gear 6 PROCEDURE 1. Release the four allen screws (2) securing the mounting plate (3) of the Gas Spring (4 mm allen wrench). 2 2 3 4 2. Carefully remove the mounting plate (3) making sure that the felt disk (4) remains in place. 4 CAUTION Take care to ensure that the old Gas Spring does not fall out of the mounting plate, during the handling of the mounting plate. Chapter 9 Page no. 1236 JC-DR-A-224.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A224 - Gas Spring for Rotation Worm Gear 3. By hand, carefully pull the old Gas Spring (5) to remove it from the mounting plate (3). 5 3 4. By hand, carefully push the new Gas Spring (6) to into the mounting plate (3). 6 3 6 3 Page no. 1237 JC-DR-A-224.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A224 - Gas Spring for Rotation Worm Gear 5. Place the mouting plate back on to its mounting place in the Gantry. Ensure that the bottom end of the new Gas Spring is centered on the felt disk (7). 10 9 8 7 CAUTION Take care to ensure that the new Gas Spring does not fall out of the mounting plate, during the handling of the mounting plate. Do NOT adjust the positions of the large allen screw (8) and column (9) which accomodates the Gear Gas Spring. 6. Gently push on the column (9) to compress the Gas Spring against the felt disk, and insert the two rear allen screws (10). Apply blue Loctite 243 to secure the thread of the two rear allen screws. 7. Apply blue Loctite 243 to secure the thread of the two front allen screws (11). Fully tighen both front (11) and rear (10) allen screws (4 mm allen wrench). Use a torque wrench to ensure that the four allen screws securing the mounting plate are tightened to 5.5 Nm. 10 11 7 COMPLETION None. Chapter 9 Page no. 1238 JC-DR-A-224.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A227 - Rotation Potentiometer Job Card D/R A227 - Rotation Potentiometer 1 Chapter 9 SUPPLIES Rotation Potentiometer 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 75 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 PREREQUISITES • Switch off the Gantry power. • Remove the front covers (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). • Loosen and remove the Gantry curtain (refer to Job Card D/R A208 - Gantry Curtains on page 1193) for access to the Rotation Potentiometer (1). 1 Page no. 1239 JC-DR-A-227.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A227 - Rotation Potentiometer 6 PROCEDURE 6-1 Disassembly of the Rotation Potentiometer 1. Remove the Rotation Board supporting plate (2.5 mm allen wrench). 2 3 Note: In the following step, take care not to lose the tension spring (3) when loosening the screw (2). 2. Remove the screw (2) securing the Potentiometer support (2 mm allen wrench). 3. Unplug the Potentiometer cable (W220) from the Rotation Board (connector J11). Chapter 9 Page no. 1240 JC-DR-A-227.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A227 - Rotation Potentiometer 6-2 Reassembly of the Rotation Potentiometer Reverse the disassembly procedure. Add the following steps to the reassembly procedure: • Turn the potentiometer axis to one of its travel limits, then make 4 five turns in the other way (approximately half way). • Apply blue Loctite on the threads of both securing screws (2 and 3) before tightening them. • When the Potentiometer and its support plate are reassembled in the column, place the spring (4) as shown in the illustration. • Route the Potentiometer cable (W220) as shown below, and plug it into the J11 connector on the Rotation Board. J11 6-3 Check the Rotation Movement 1. Move the compression paddle out of compression. Then check that all four sets of arm left/right control buttons are operational (check each button for arm rotation movement). 2. Rotate the arm to its left and right limits. Software preset limits should stop movement (185° counterclockwise, 165° clockwise). 3. During arm movement, check for any noise that indicates excessive friction or binding. Page no. 1241 JC-DR-A-227.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A227 - Rotation Potentiometer 6-4 • 7 Troubleshooting If the error message 112/001 appears after potentiometer replacement, check the voltage between the center pin of the rotation potentiometer connector and ground. The following values must be obtained, according to the arm position: - Arm at +180°; V = 2.825 V ±0.05 V dc. - Arm at 0°; V = 1.65 V ±0.05 V dc. - Arm at -165°; V = 0.606 V ±0.05 V dc. COMPLETION Carry out the following calibration: Job Card CAL A021 - Arm Rotation Calibration on page 1679. Chapter 9 Page no. 1242 JC-DR-A-227.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A228 - Rotation Motor Job Card D/R A228 - Rotation Motor 1 Chapter 9 SUPPLIES Rotation Motor 2 • • TOOLS Standard Tool Box Hub extractor 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 75 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 PREREQUISITES • Lower the arm for good access to the Rotation Motor (1). • Switch off the Gantry power. • Remove the arm and the front covers (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). • Loosen and remove the Gantry curtain (refer to Job Card D/R A208 - Gantry Curtains on page 1193). Page no. 1243 JC-DR-A-228.fm 1 Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A228 - Rotation Motor 6 PROCEDURE 6-1 Disassembly of the Rotation Motor 1. Unplug the Motor cables W206 and W205 from the Rotation Board (connector J10 and J9). 2 3 4 5 2. 3. 4. 5. 6. If an earth cable (2) exists, disconnect the earth cable that is connected to one of the four screws (2). Remove the four screws (3) securing the Motor (5 mm allen wrench). Remove the Motor from its belt (5). Release the screw securing the gear (4) and the motor (2 mm allen wrench). Use a hub extractor to extract the gear (17 mm open-ended wrench). Chapter 9 Page no. 1244 JC-DR-A-228.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A228 - Rotation Motor 6-2 Reassembly of the Rotation Motor Reverse the disassembly procedure. Add the following step to the reassembly procedure: • Apply blue Loctite to the threads of the motor securing screws before tightening them. • Ensure that there is a gap of 0.2 mm - 0.3 mm as indicated in the illustration. • The replacement Rotation Motor will have an earth cable, so ensure you connect and route the earth cable to the top right corner motor fixing plate as shown above. When routing the earth cable, make sure all excess cable is secured using a cable tie so that the excess cable cannot interact with other moving parts of the Gantry. When routing the Motor cables W206 and W205 to the Rotation Board (connector J10 and J9), ensure that they are routed and secured with cable ties as indicated in the illustration. • Motor Gap Cable Tie Cable Tie 6-3 Check the Rotation Movement 1. Move the compression paddle out of compression. Then check that all four sets of arm left/right control buttons are operational (check each button for arm rotation movement). 2. Rotate the arm to its left and right limits. Software preset limits should stop movement (185° counterclockwise, 165° clockwise). 7 COMPLETION None Page no. 1245 JC-DR-A-228.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A228 - Rotation Motor This page is blank. Chapter 9 Page no. 1246 JC-DR-A-228.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A229 - Rotation Brake Job Card D/R A229 - Rotation Brake 1 • • Chapter 9 SUPPLIES Rotation Brake Two transportation screws (found either in your service kit or supplied with the new brake). M5x50 ISO 4762 - total length 50 mm, length of thread 22 mm. 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 90 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 PREREQUISITES • Switch off the Gantry power. • Remove the top right and left column covers and remove the front covers (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). • Turn the Gantry power on. • Raise the arm to have good access to the Rotation Brake (1) from the rear of the Gantry. • Switch off the Gantry power. • Loosen and remove the Gantry curtain (refer to Job Card D/R A208 - Gantry Curtains on page 1193). 1 Page no. 1247 JC-DR-A-229.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A229 - Rotation Brake 6 PROCEDURE This list of screws in the following table help reading the procedure: Screw Name How many Allen Wrench (mm) A Transportation Screws 2 4 B Brake Holder Plate Screws 6 5 C Pulling Screws 4 4 D Pushing Screws 4 5 6-1 A B C D Disassembly of the Rotation Brake 1. Insert and tighten the two transportation screws (2) (4 mm allen wrench). CAUTION Do not dismount the brake without the transportation screws in place and tightened. 2. Disconnect the Brake cable (W219) from the Rotation Board (connector J6). 3. Release the six screws (3) securing the Brake holder plate (5 mm allen wrench). Chapter 9 2 3 Page no. 1248 JC-DR-A-229.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A229 - Rotation Brake 4. Remove the Brake holder plate (4) which holds the two parts of the brake; the non-mobile assembly (5) and the mobile assembly (6). Currently the gap between the mobile and the non-mobile part is set to zero due to the presence of the transportation screws. Target: 0.15 m m Friction Area 8 GAP N on‐M obile Assem bly Mobile Assembly 7 Brake D isk 4 4 5 6 5 6 5. Release the four pulling screws (7) (4 mm allen wrench). 6. Loosen the four pushing screws (8) (5 mm allen wrench). 7. Release and remove the transportation screws. 6-2 Reassembly of the Rotation Brake 6-2-1 Prerequisite • Use Loctite cleaner to clean the surface of the brake disk. 6-2-2 Prepare the New Brake on a Table 1. Loosen the two transportation screws (4 mm allen wrench) on the new brake until you have a 5 mm gap between the non-mobile and the mobile assemblies of the brake. 2. Grease the springs that are now accessible between the non-mobile and the mobile assemblies. 3. Tighten the transportation screws. 4. Mount the new brake on the holder plate, tighten the pulling screws (7) only. 6-2-3 Assemble the Brake on the Gantry 1. Apply blue Loctite to the threads of the six screws (3) securing the brake holder plate (5 mm allen wrench). Use a Torque meter and tighten them to 20 N.m ± 1 N.m. 2. Remove the transportation screws. CAUTION Keep the transportation screws in a safe place for the next change. Page no. 1249 JC-DR-A-229.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A229 - Rotation Brake 3. Loosen the pulling screws (7) until they protrude by 3 mm from the holder plate. 4. Tighten the pushing screws (8) to reduce the gap between the mobile and non mobile parts of the brake. View the gap through the four openings and continue until the gap is close to 0 mm (starting value for the next step). 5. Connect the Brake cable (W219) to the Rotation Board (connector J6). 6-3 Brake Positioning Adjustments 1. Use a 0.15 mm feeler gauge as shown in the illustration to avoid touching the springs: 1. Try to insert the feeler gauge through the left side of F E the opening (E), loosen the pushing screw until the feeler gauge slips in, 2. Try to insert the feeler gauge through the right side of the opening (F), loosen the pushing screw until the feeler gauge slips in, G 3. Try to insert the feeler gauge through the right side of the opening (G), loosen the pushing screw until the H feeler gauge slips in, 4. Try to insert the feeler gauge through the left side of the opening (H), loosen the pushing screw until the feeler gauge slips in, 2. Check for each opening that: 1. The 0.15 mm feeler gauge slips in. 2. The 0.18 mm feeler gauge does not enter. If it does, reinsert the 0.15 mm feeler gauge and retighten the appropriate pushing screw. 3. Tighten the four pulling screws. 6-4 Check the Rotation Movement 1. Move the compression paddle out of compression. Then check that all four sets of arm left/right control buttons are operational (check each button for rotation movement of column). 2. Rotate the arm to its left and right limits. Software preset limits should stop movement (185° counterclockwise, 165° clockwise). 6-5 Brake Fine Adjustment During arm movement, check for any noise that indicates excessive friction or binding. 7 COMPLETION None Chapter 9 Page no. 1250 JC-DR-A-229.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A230 - Rotation Gas Spring Job Card D/R A230 - Rotation Gas Spring 1 Chapter 9 SUPPLIES Rotation Gas Spring 2 • TOOLS Standard Tool Box (preferably use Allen socket wrench with extension (especially due to presence of Loctite on screws)) Channel Lock Pliers • 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 90 minutes 4 SAFETY PRECAUTIONS WARNING The rotation gas spring has a larger mechanical energy when the tube head is at angles of greater than 0°. To minimize the risk of rapid gas spring movement due to stored mechanical energy, ensure that the Tube Head is set to 0° before you proceed. WARNING The Gantry must be powered off. 5 PREREQUISITES • • Ensure that the orientation Tube Head is set to 0 degrees. Switch off the Gantry power. Remove the front covers and the column covers (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). • • Switch on the Gantry power. Use the lift command buttons to move the arm vertically until the two springs (1) are fully visible in the opening at the rear of the column frame. Switch off the Gantry power. Use bent needle-nose pliers to unhook and remove the two springs from the curtains. • • 1 2 CAUTION If the extremity of the spring slides out of the pliers, the spring can fly out and cause injury. TIP: It is recommended that you use cable ties to temporarily attach the lower curtain (2) to the coolant pipes so that the curtain does not Page no. 1251 JC-DR-A-230.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A230 - Rotation Gas Spring loose its position during this procedure. • Loosen and remove the Gantry curtain for access to the Rotation Gas Spring (A). A 6 PROCEDURE 6-1 Disassembly of the Rotation Gas Spring 1. Remove the four screws (1) that secure the UPlate (2) to the lower support (4 mm allen wrench), and remove the U-Plate from the lower support. 2. Loosen the four screws (3) of the lower support plate by half a turn only (6 mm allen wrench). 3 1 2 WARNING Do not remove the four screws (3) . 6 3. Loosen the fifth screw (4) of the lower support plate (6 mm allen wrench). 5 4. Untighten and remove the screw (5) from the bearing (6 mm allen wrench). 4 5. Pull and remove the lower end of the Gas Spring. 6. Turn the Gas Spring anti-clockwise until it is released from the upper fixing (which is behind the Rotation Board), and remove the Gas Spring. If necessary, use channel lock pliers to initially turn the Gas Spring. 7. Unscrew (turn anti-clockwise) the lower (6) fixing part from the old Gas Spring. Chapter 9 Page no. 1252 JC-DR-A-230.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A230 - Rotation Gas Spring 6-2 Reassembly of the Gas Spring 1. Attach the lower fixing part (6) to the new Gas Spring. 2. Carefully position the new Gas Spring behind the Rotation Board, feel for the upper fixing part. Turn the new Gas Spring clockwise until it is firmly secured to the upper fixing part. 3. Push the lower end of the Gas Spring and the lower fixing part on to the lower support. 4. Insert and tighten the screw (5) into the bearing (6 mm allen wrench). 5. Tighten the fifth screw (4) of the lower support plate (6 mm allen wrench). While tightening the fifth screw of the lower support plate, ensure that the bottom of the Gas Spring (8) is aligned (within approximately 2 mm) with the bottom of the arm (9). 6. Tighten the four screws (3) of the lower support plate by half a turn (6 mm allen wrench). 7. Place the U-Plate (2) on the lower support, and secure it with the four screws (1) (4 mm allen wrench). 6-3 9 8 Check the Rotation Movement 1. Move the compression paddle out of compression. Then check that all four sets of arm left/right control buttons are operational (check each button for rotation movement of column). 2. Rotate the arm to its left and right limits. Software preset limits should stop movement (185° counterclockwise, 165° clockwise). 3. During arm movement, check for any noise that indicates excessive friction or binding. 7 COMPLETION None Page no. 1253 JC-DR-A-230.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A230 - Rotation Gas Spring This page is blank. Chapter 9 Page no. 1254 JC-DR-A-230.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly Job Card D/R A232 - Lift Screw Assembly 1 Chapter 9 SUPPLIES Determine the type of Lift Screw Assembly that is installed in the system, as indicated below. TABLE 1 - LIFT SCREW ASSEMBLY TYPE IDENTIFICATION QUICK GUIDE Lift Type in Install Base System No brake (Type 1) Top brake (Type 2) Brake motor (Type 3) pre-January 2008 January 2008 June 2011 L-bracket at top of Lift Screw Assembly Black with no threaded holes Silver with threaded holes Silver with no threaded holes Motor power cable YES YES YES Motor earth cable NO YES YES Motor brake cable NO NO YES Manufacturing Date Physical Identification Method (required on Type 1 or Type 2 systems to know if Lift Screw Assembly upgraded to newer type) Order the appropriate Lift Screw Assembly with Motor according to the Type of Lift Screw Assembly installed in the system: • For systems with Type 1 and Type 2, order a Type 2 Lift Screw Assembly with Motor (5191096) • For systems with Type 3, order a Type 3 Lift Screw Assembly with Motor (5337148) You may have determined with earlier troubleshooting that only the Lift Screw needs changing, rather than the entire Lift Screw Assembly with Motor. In this case, order the appropriate Lift Screw according to the Type of Lift Screw Assembly installed in the system: • For systems with Type 1 and Type 2, order a Type 2 Lift Screw without Motor (5391083) • For systems with Type 3, order a Type 3 Lift Screw without Motor (5373048) 2 • • TOOLS Standard Tool Box including a universal joint (knuckle joint) for access to left hand side Cardan screws located behind the Rotation board Gantry LOTO Tool Page no. 1255 JC-DR-A-232.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly 3 REQUIRED EFFORT Personnel: 1 Field Engineers Time: 2 hours 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 • • • PREREQUISITES Remove all the parts of Gantry Column Covers (except: Column Cover Bottom Rear) (Refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). Remove the Compression arm covers (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). If a Type 2 Lift Screw Assembly exists and is fitted with the Top Brake, remove the Lift Screw Assembly Top Brake that is currently on the old Lift Screw Assembly in the Gantry. Refer to Disassembly of the old Lift Screw Assembly Top Brake on page 1280 in Job Card D/R A233 - Lift Screw Assembly Top Brake. Chapter 9 Page no. 1256 JC-DR-A-232.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly 6 PROCEDURE 6-1 Disassembly of Gantry Curtains 1. Remove the two springs of curtains from the back of the Gantry. (Using a crook or tiewrap could help). If necessary, move the trolley position so that the springs (1) that attach upper and lower curtains are visible. 1 2. Cut the tiewrap fixing the clutch cable to curtain (2). 3. Release and remove the two lower screws securing the lower curtain (3) (3 mm allen wrench). 3 2 4. Remove the lower curtain. Page no. 1257 JC-DR-A-232.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly 6-2 Disassembly of the Old Lift Screw Assembly 1. Release the two lower screws (3) on the lower part of each of the Curtain Ribs (3 mm allen wrench). 3 4 2. Release the four nuts (4) securing the lower X plate (17 mm open-ended wrench) and remove the lower X-Plate by sliding it under the remaining Curtain Ribs. 3. Remove the Gantry LCD readout and base cover of the Gantry. 4. Release the nuts of the front Curtain Roller (5) (19 mm open-ended wrench) and remove it from the base of the Gantry. 5 Chapter 9 Page no. 1258 JC-DR-A-232.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly 5. If necessary, power on the system and use the Arm control buttons to lower the lift position until the two right hand side fixing screws (6) of the Cardan are visible. 6. Release two right hand side Cardan screws (6) from the Cardan. (6 mm socket wrench). If the Compression Arm is too high, this back rail hides the two right hand side Cardan fixing screws. 6 WARNING IMPORTANT SAFETY NOTE: At this stage DO NOT remove the two left hand side fixing screws of the Cardan. You must raise the trolly and secure it with a belt before you remove the two left hand screws, as described in the following steps. If you remove the two left hand side fixing screws of the Cardan, the entire Cardan assembly and associated Compression Arm will fall quickly. 7. If necessary, power on the system and use the Arm control buttons to until the lift position is at its maximum possible height. The lift position must be at its maximum possible height in order to allow you to remove the Lift Screw Assembly. 8. Perfom a mechanical LOTO as follows: If you do not have a Gantry LOTO Tool, use a nylon belt to secure the Compression Arm to the top of the Gantry as indicated below. Adjust the lift position by rotating the Lift Screw counter clockwise to Page no. 1259 JC-DR-A-232.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly tighten the belt a little to check the correctness of nylon belt installation. Other belt end finishes here Route behind X-Plate One belt end starts here Loop belt here If you do have a Gantry LOTO tool, use the following sub-steps: a. If necessary (i.e. if the Lift upper limit is not at the maximum setting), manually raise the lift position by rotating the Lift Screw anti-clockwise (13 mm or 17 mm hexagonal wrench) to the correct height, so that the disk of the Arm can be accommodated by the recess of located on the Gantry LOTO Tool. Bottom part of the recess. Bottom part of the disk must be slightly higher than the bottom part of the recess on the rear of the Gantry LOTO Tool. Chapter 9 Page no. 1260 JC-DR-A-232.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly b. Position the top lip of the Gantry LOTO Tool so that it sits behind the inner surface of the Gantry. Slide Top lip of the Gantry LOTO Tool behind the inner edge of the Gantry. c. Push the knob (7) upwards so that the lower moveable lip (8) disappears into the lower part of the Gantry LOTO Tool. 9 7 8 d. With the lower lip hidden, push the lower part of the Gantry LOTO Tool into the Gantry so that it sits flush with the outer surface of the Gantry framework. If necessary, look down the guidance hole (9) to check the bottom part of the Arm disk is visible above the lower surface of the recess. e. When the lower part of the Gantry LOTO Tool is flush with the outer surface of the Gantry framePage no. 1261 JC-DR-A-232.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly work, let go of the knob so that the spring loaded lower lip moves into the lock position. f. Look down the guidance hole (9) to check the bottom part of the Arm disk is between 0 and 3 mm above the lower surface of the recess. If it is more than 3 mm above the lower surface of the recess, manually lower the lift position by rotating the Lift Screw clockwise (13 mm or 17 mm hexagonal wrench). g. Physically verify that the Gantry LOTO Tool is locked into position. WARNING You MUST ensure that the nylon belt or Gantry LOTO Tool secures the Compression Arm. If you remove the two left hand side fixing screws of the Cardan without securing the Compression Arm, the entire Cardan assembly and associated Compression Arm can fall quickly when you release the last fixing screw. 9. Release two left hand side Cardan screws (10) from the Cardan. To access these screws from behind the Rotation board, use a 6 mm socket wrench with universal joint (knuckle joint). 10 Chapter 9 Universal joint (knuckle joint) Page no. 1262 JC-DR-A-232.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly 10. Release the screws (11) of Upper L-Shape Bearing Housing (12) (5 mm allen wrench) and remove it. 12 11 11. Power off the Gantry. 12. If you are changing a Type 2 Lift Screw Assembly, disconnect the earth cable that is routed to the bottom left corner of the Detector Power Supply plate. If theType 2 Lift Screw Assembly also has the Top Brake installed, remove the Top Brake cable from the J6 connector on the Lift Board. If you are changing a Type 3 Lift Screw Assembly, disconnect the earth cable that is routed to the bottom left corner of the Detector Power Supply plate and disconnect the Motor Brake cable that is connected to the J6 connector on the Lift Board. 13. Remove the Lift Board (refer to Job Card D/R A201 - Lift Board on page 1161). This exposes the screws that connect the lower part (Bearing Block) of the Lift Screw Assembly to the Gantry frame. 14. When you remove the Lift Board, route the cables (13) from the DC motor though the side of the Page no. 1263 JC-DR-A-232.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly Gantry and place them in close proximity to the DC motor. 13 15. Release the four screws (14) that connect the lower part (Bearing Block) of the Lift Screw Assembly to the Gantry frame (5 mm allen wrench). While releasing these screws, carefully hold the base (15) of the Lift Screw Assembly so that it does not fall. 15 14 Chapter 9 Page no. 1264 JC-DR-A-232.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly 16. Remove the old Lift Screw Assembly (16) from the Gantry. 16 Page no. 1265 JC-DR-A-232.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly 6-3 Preparation of the New Lift Screw 6-3-1 Clean Leadscrew The Lift Screw Assembly is supplied with an anti-corrosion oil that is incompatible with the grease for the Lead Screw, resulting in the degradation of the Lift Screw Assembly. Clean the Leadscrew with a cleaner and a cloth until all of the old grease is fully removed, using the following sub-steps: 1. Apply Cleaner Spray to the Leadscrew. Recommended product: 3M Cleaner Spray (3M PN 50098).. Note: When working with grease, and to protect your hands against the Leadscrew, always wear rubber cloves. 2. Use ORA Wipes (or equivalent) cloths for removing the grease from the Leadscrew. Rotate the ORA Wipes cloth around the Leadscrew and draw wipe both direction along the entire length of the Leadscrew as shown below. Draw wipe in both directions along the entire length of the Leadscrew Take care not to use the type of cloth wipes that could disintegrate, since the loosened threads or particles may get mixed with the grease. Chapter 9 Page no. 1266 JC-DR-A-232.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly 3. Use ORA Wipes (or equivalent) cloths for removing the grease from the Leadscrew. Rotate the ORA Wipes cloth around the Leadscrew and rotate Lead Screw by other hand along the entire length of the Leadscrew as shown below. Rotate Leadscrew by other hand along the entire length of the Leadscrew Take care not to use the type of cloth wipes that could disintegrate, since the loosened threads or particles may get mixed with the grease. 4. Repeat these steps above several times until the Leadscrew is cleaned. A well cleaned Leadscrew looks like that shown below. Page no. 1267 JC-DR-A-232.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly 6-3-2 If necessary, install the Lift Motor When you receive a new Lift Screw Assembly, it will either be partially or fully constructed, as follows: • Lift Screw Assembly with Brake Motor (5337148) - Lift Screw is pre-connected to the Lift Motor Frame, and the Brake Motor is disconnected • Lift Screw Assembly without Motor (5373048) - Lift Screw is pre-connected to the Lift Motor Frame • Lift Screw Assembly without Motor (5391083) - Lift Screw is disconnected from the Lift Motor Frame If necessary (in the case of 5391083), to attach the Lift Screw to the Lift Motor Frame, use the four M6 allen screws supplied with the Lift Screw Assembly to secure the Bearing Cap at the bottom of the Lift Screw to the Lift Motor Frame. Apply Loctite 270 and a torque of 7 ± 1 Nm when securing the M6 allen screws. If necessary (in the case of 5337148), to attach the Brake Motor to the bottom of the Lift Screw Lift Motor Frame, use the following steps: 1. Insert the Brake Motor into the Lift Motor Frame, ensuring that the bottom of Lift Screw (1) is aligned with the top of the Brake Motor (2). 2. Use the four M5 allen screws supplied with the Lift Screw Assembly to secure the Brake Motor to the Lift Motor Frame. Apply Loctite 270 and a torque of 5 ± 1 Nm when securing the M5 allen screws. If necessary (in the case of 5373048 and 5391083), recouperate the original Motor from the original Lift Screw Assembly, and attach the Motor to the bottom of the Lift Screw Lift Motor Frame, using the following steps: 1. Insert the Motor into the Lift Motor Frame, ensuring that the bottom of Lift Screw (1) is aligned with the top of the Motor (2). 2. Use the four M5 allen screws from the original Lift Screw Assembly to secure the Motor to the Lift Motor Frame. Apply Loctite 270 and a torque of 5 ± 1 Nm when securing the M5 allen screws. 1 Chapter 9 2 Page no. 1268 JC-DR-A-232.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly 6-4 Reassembly of the New Lift Screw Assembly 1. Rotate the Cardan Nut assembly clockwise until the top of the Cardan Nut assembly is 16 cm from the bottom of the L-Bracket at the top of the Lift Screw Assembly. Ensure that the four holes in the Cardan Nut assembly are pointing in the correct direction, so that they will face out of the Gantry when the Lift Screw Assembly is re-installed (i.e. the L-bracket holes are to the right hand side and 90° of the Cardan Nut assembly holes). Cardan Nut Assembly Note: The position of the Cardan Nut Assembly is important so that its threaded holes will be aligned with the Arm frame, which is in position with the Gantry LOTO Tool/nylon belt. 2. Put the new Lift Screw Assembly in place, and tighten the four screws (1) of Lower Bearing Block with your fingers (do not use any tools). 1 Page no. 1269 JC-DR-A-232.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly 3. Gently tighten the four screws (2) of Upper Bearing Block with your fingers (do not use any tools). 2 4. If necessary, adjust the Cardan Nut Assembly position so that its threaded holes are aligned with the four holes in the Arm frame. To adjust the Cardan Nut Assembly position, rotate the Lift Screw (3) accordingly (17 mm hexagonal wrench). 3 5. Route the cables (4) from the DC motor of the new Lift Screw Assembly though the other side of the Gantry so they are in close proximity to where you will re-install the Lift Board that you previously Chapter 9 Page no. 1270 JC-DR-A-232.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly removed. 4 6. Insert and tighten the two left hand screws (5) of Cardan Assembly, ensure that you apply a torque of 20 Nm and apply Loctite 270. To access right hand screws from behind the Rotation board, use a 6 mm socket wrench with universal joint (knuckle joint). 5 Universal joint (knuckle joint) 7. Remove the physical LOTO previously applied, as follows: If you secured the Compression Arm with a nylon belt, remove the nylon belt that secured the ComPage no. 1271 JC-DR-A-232.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly pression Arm to the top of the Gantry. If you secured the Compression Arm with the Gantry LOTO tool, perform the following sub-steps: a. Push the knob (6) upwards until its maximum height. 6 b. Gently pull the lower part of the Gantry LOTO Tool away from the Gantry framework. c. Fully remove the Gantry LOTO Tool paying particular attention to not drop it. CAUTION The Gantry LOTO Tool is 0.7 kg. Be prepared to take the weight of the Gantry LOTO Tool as you pull it s lower apart away from the Gantry. If you are not prepared to take the weight of the Gantry LOTO Tool, there is a risk that it could fall on the lower parts of the Gantry (e.g. the Lift board) or your feet. 8. Adjust the lift position by rotating the Lift Screw anti-clockwise (7) (13 mm or 17 mm hexagonal Chapter 9 Page no. 1272 JC-DR-A-232.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly wrench) until the two right hand side fixing screw holes (8) of the Arm Frame are visible. 7 8 9. Insert and tighten the right left hand screws (8) of Cardan Assembly, ensure that you apply a torque of 20 Nm and apply Loctite 270. 10. Before you tighten the screws on the upper and lower parts of the Lift Screw Assembly, move the Compression Arm up and down at least two times. 11. Move the Compression Arm down and tighten the four screws (9) that connect the lower part (Bearing Block) of the Lift Screw Assembly to the Gantry frame (5 mm allen wrench). Ensure that you apply a torque of 10 Nm and apply Loctite 270. Fully tighten the four screws in the following "cross" order top left, bottom right, bottom left, top right. 9 12. Move the trolley up, and tighten the screws (10) of the upper part of the Lift Screw Assembly. Ensure that you apply a torque of 10 Nm and apply Loctite 270. Fully tighten the four screws in the following Page no. 1273 JC-DR-A-232.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly "cross" order top left, bottom right, bottom left, top right. 10 13. Replace the Lift Board that you originally had removed (refer to Job Card D/R A201 - Lift Board on page 1161). The referenced Job Card instructs you how to connect all the cables back to the Lift Board. 14. If you are changing a Type 2 Lift Screw Assembly, route and connect the Lift Motor earth cable to the bottom left corner of the Detector Power Supply plate. If you are changing a Type 3 Lift Screw Assembly, route and connect the Lift Motor earth cable to the bottom left corner of the Detector Power Supply plate, and connect the brake cable to the J6 connector on the Lift Board. 15. Replace the curtains (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). 16. If the Type 2 Lift Screw Assembly also had a Top Brake installed, re-intsall the Lift Screw Assembly Brake (refer to Re-assembly of the new Gantry Lift Screw Brake on page 1283 in Job Card D/R A233 - Lift Screw Assembly Top Brake. Chapter 9 Page no. 1274 JC-DR-A-232.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly 6-5 Grease the New Lift Screw 1. Apply Grease (for Lift and Rotation) (5212483) (Orapi CT FLON 607) to the Leadscrew by hand. Ensure the Leadscrew is homogeneously covered with grease, as shown in illustration 1. CAUTION Do not use any other type of grease, other than Grease for Lift and Rotation (5212483) (Orapi CT FLON 607). Do not use a brush to apply the grease as this may introduce foreign objects on to the Leadscrew. Only use your hands to apply the grease to the Leadscrew. About 35 g (1.23 oz) of grease is sufficient to cover the entire length of the Leadscrew. Page no. 1275 JC-DR-A-232.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly ILLUSTRATION 1 - EXAMPLES OF GOOD AND BAD GREASING OF THE LEADSCREW Good Uniformly applied grease. Bad Too much applied grease can splatter to column wall. Clean surfaces, walls and cables from spattered grease. 2. Once you have finished applying grease to the entire Leadscrew, use the slow speed Arm Control buttons to drive the Lift over the whole range up and down two times in slow speed. 3. Use the fast speed Arm Control buttons to drive the Lift over the whole range up and down a few times in fast speed. 4. Check how grease has been spread to the screw. Examples of well spread grease, smoothly and uniformly along the whole screw length, with no splattered grease are shown in illustration 2. Chapter 9 Page no. 1276 JC-DR-A-232.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly ILLUSTRATION 2 - EXAMPLES OF WELL APPLIED GREASE AFTER LIFT MOVEMENT If there are some areas where no grease exists, apply grease to these areas, move the Arm again in slow and fast speeds, and check the greasing again. 6-6 Check Column Movement 1. Move the compression paddle out of compression. Then check that all four sets of column up/down control buttons are operational (check each button for up and down movement of the column). 2. Move column to its upper and lower limits. Software limits should stop movement. If the software limits fail, the optical forks are used to recognize and stop any movement before impact with mechanical stops. 3. During column movement, check for any noise that indicates excessive friction or binding. Page no. 1277 JC-DR-A-232.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A232 - Lift Screw Assembly This page is blank. Chapter 9 Page no. 1278 JC-DR-A-232.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A233 - Lift Screw Assembly Top Brake Job Card D/R A233 - Lift Screw Assembly Top Brake 1 Chapter 9 SUPPLIES Lift Screw Assembly Top Brake 2 APPLICABILITY This Job Card is only applicable to systems with a Type 2 Lift Screw Top Assembly. A Type 2 Lift Screw Top Assembly has a silver L-bracket withthreaded holes, as indicated below. Type 1 3 Type 2 Type 3 TOOLS Standard Tool Box 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 1 hour 5 SAFETY PRECAUTIONS WARNING The Gantry must be powered OFF. 6 PREREQUISITES Switch OFF the Gantry power. Page no. 1279 JC-DR-A-233.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A233 - Lift Screw Assembly Top Brake 7 PROCEDURE 7-1 Disassembly of the old Lift Screw Assembly Top Brake 1. Remove the right hand side Gantry Column Covers to reveal the location of the Lift Screw Assembly Top Brake and the Lift Board (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). 2. Disconnect the Lift screw Assembly Top Brake cable (W510) from the J6 connector on the Lift Board. To Brake J6 Cut the cable ties to secure the Lift screw Assembly Top Brake cable (W510) up the side of the Gan- Chapter 9 Page no. 1280 JC-DR-A-233.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A233 - Lift Screw Assembly Top Brake try as shown below. Cable Tie Cable Tie Cable Tie Cable Tie Page no. 1281 JC-DR-A-233.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A233 - Lift Screw Assembly Top Brake 3. Release and carefully remove the four allen screws (1) that secure the Lift screw Assembly Top Brake (2) to the bracket (4 mm allen wrench). 2 1 4. Carefully remove the Lift Screw Assembly Top Brake (2) from the bracket (3). 3 Chapter 9 Page no. 1282 JC-DR-A-233.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A233 - Lift Screw Assembly Top Brake 7-2 Re-assembly of the new Gantry Lift Screw Brake 1. Prepare to top of the Lift Screw Assembly so that the screw’s hexagonal shape is in the correct orientation for the Lift Screw Assembly Top Brake to fit onto it. Turn the Lift Screw so that the corner of the screw’s hexagonal shape is pointing towards the edge of the Gantry wall. Brake cable in this corner 1 Gantry Wall Top View 2. Place the Lift screw Assembly Top Brake (2) so that the corner with the cable (2) is on the right hand side (when viewing the Gantry wall front on) as illustrated below. 2 3 4 Page no. 1283 JC-DR-A-233.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A233 - Lift Screw Assembly Top Brake 3. Lower the Lift screw Assembly Top Brake (2) down on to the top of the Lift screw Assembly, and ensure that the holes (4) in the Lift screw Assembly Top Brake align with the threaded holes of the bracket (5). You may need to move the Lift Screw Assembly Top Brake until each side is flush to the bracket. 5 4. Secure the Lift Screw Assembly Top Brake to the bracket with the four allen screws (6) (4 mm allen wrench). Progressively tighten the opposite corners together so that equal pressure is applied to the fixations between the bracket and the Lift Screw Assembly Top Brake. 6 5. Connect the Lift screw Assembly Top Brake cable (W510) to the J6 connector on the Lift Board, and Chapter 9 Page no. 1284 JC-DR-A-233.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A233 - Lift Screw Assembly Top Brake route it directly upwards towards the brake. Use cable ties to secure the Lift screw Assembly Top To Brake J6 Brake cable (W510) up the side of the Gantry as shown below. Gather the excess cable at the end of Page no. 1285 JC-DR-A-233.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A233 - Lift Screw Assembly Top Brake the brake and create a loop with a cable tie. Cable Tie Cable Tie Cable Tie Cable Tie Chapter 9 Page no. 1286 JC-DR-A-233.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A233 - Lift Screw Assembly Top Brake 7-3 Check operation of Lift Screw Assembly Top Brake 1. Power up the Senographe system. 2. Use the control buttons to move the column up and down. When you stop the movement listen out for the clamping noise of the Lift Screw Assembly Top Brake claming the Lift Screw Assembly Top Brake. With normal brake operation, the clamping noise occurs within one second of the stopping of the column movement. If you cannot hear the clamping noise, then: • Check the W510 cable connection to the J6 connector on the Lift Board. • Check that the CPLD firmware on the Lift Board is 10.0.1 or later. To do this, go to the Service Desktop home page and observe the CPLD entry next to the Lift Board in the list of current firmware versions. 3. If you can hear the clamping noise, then the Lift Screw Assembly Top Brake operation is normal. Reinstall the right hand side Gantry Column Covers (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). Page no. 1287 JC-DR-A-233.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A233 - Lift Screw Assembly Top Brake This page is blank. Chapter 9 Page no. 1288 JC-DR-A-233.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A243 - Compression Potentiometer and Cable Job Card D/R A243 - Compression Potentiometer and Cable 1 Chapter 9 SUPPLIES Compression Potentiometer and Cable (with Support) 2 • • TOOLS Standard Tool Box Mammography compression scale with digital display 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 1 hour (incl. calibrations and functional checks) 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 • • • • PREREQUISITES Rotate the arm to 0°. Lower the arm until you have a good access to the Compression Potentiometer. Switch off the Gantry power. Remove the arm covers (See Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). Page no. 1289 JC-DR-A-243.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A243 - Compression Potentiometer and Cable 6 PROCEDURE 6-1 Disassembly of the Potentiometer 1. Disconnect the Potentiometer cable (W303) from the Compression Board (connector J6). 2. Release the screw securing the extremity of the position detecting wire (1) (3 mm Allen wrench). 1 3. Identify the type of Compression Potentiometer currently installed (see illustration below) to determine your next step. Type 1 Type 2 Type 3 Determine your next step: • If you have a Type 1 or Type 2 Compression Potentiometer, go to step 6. • If you have a Type 3 Compression Potentiometer, go to step 4. 4. Remove the screws (2) securing the Compression Potentiometer to the Compression Potentiometer Chapter 9 Page no. 1290 JC-DR-A-243.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A243 - Compression Potentiometer and Cable Support (cross-head screwdriver). 2 (Step applicable for Type 3 Compression Potentiometers only) 5. Remove the faulty Compression Potentiometer (3) from the Compression Potentiometer Support. 3 (Step applicable for Type 3 Compression Potentiometers only) 6. Remove the Allen screws (4) securing the Compression Potentiometer Support (3 mm Allen wrench). Then remove the Compression Potentiometer Support plus Potentiometer (for Type 1/Type 2) or Compression Potentiometer Support (Type 3) from the Compression Assembly frame. 4 4 4 Type 1 Type 2 Page no. 1291 JC-DR-A-243.fm Type 3 Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A243 - Compression Potentiometer and Cable 6-2 Installation of the New Potentiometer 1. Remove the lower two of the three Compression Potentiometer Support screws (1). 1 2. Loosen the remaining third screw on the left upper corner of the Compression Potentiometer Support. This allows inserting the Compression Potentiometer Support attachment screws. Note: Do not remove the upper left screw (2), only loosen it slightly. 2 3. Place the Compression Potentiometer and its Support (with the remaining loose screw) on the Compression Assembly frame and insert and tighten the two M4 Allen screws (3) (3 mm Allen wrench) to attach the Support to the Compression Assembly frame. When attaching the Support, ensure you use the correct holes on the Support in order to align the potentiometer wire vertically. Apply Loctite Chapter 9 Page no. 1292 JC-DR-A-243.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A243 - Compression Potentiometer and Cable 243 (or equivalent medium strength locking compound) to the screws. See picture below. 3 4. Insert and tighten the two removed lower M4 screws (4) to the corners of the Compression Potentiometer Support to attach the Compression Potentiometer firmly to the Support. Tighten the third screw also on the upper left corner. 4 5. Route the Compression Trolley cable W304b (P/N 2379180) and the Potentiometer cable (W303), Page no. 1293 JC-DR-A-243.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A243 - Compression Potentiometer and Cable and secure them with cable ties as shown below (5). 5 6. Connect the Compression Potentiometer (W303) cable to the J6 connector on the Compression board. 7. Attach the potentiometer wire loop to the Compression Trolley attachment point (6) with an M4 screw (3 mm Allen wrench). Check the potentiometer wire is vertically installed. If the potentiometer wire is vertical, check if the correct Support holes have been used to attach it to the Compression Assembly frame. 6 8. Check the Compression Movement, as follows: Chapter 9 Page no. 1294 JC-DR-A-243.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A243 - Compression Potentiometer and Cable 1. Check that both sets of compression/decompression pedals and the manual compression knobs located on the paddle holder all function correctly. That is, the paddle moves up or down in response to each control. 2. Use the mammography compression scale placed between the Bucky and the compression paddle to check calibration of the compression force display on the Gantry readout. Measure one point at 5 daN and one point at 15 daN. The value on the Gantry readout must agree within ±1 daN. If it does not, perform Job Card CAL A048 - Calibration of Compression Force Sensor on page 1709. Note: If the recommended compression measurement tool is not available, this verification can be done by lowering the paddle close to the top surface of the Bucky, installing the magnification device in the upper pair of holes, and connecting a spring dynamometer (calibrated from 0 kg to 15 kg) between the compression paddle and the magnification device. 7 COMPLETION Carry out the following calibration procedures: Calibrations - Checks Job Card Gantry Compression Force Sensor Job Card CAL A048 - Calibration of Compression Force Sensor on page 1709 Compression Thickness Job Card CAL A050 - Compression Thickness Calibration on page 1721 If Compression Thickness not OK, repeat calibrations from Compression Force Sensor Flat field tests Job Card ELE M032 – IQ Tools Flat Field Test on page 813 Mag Resolution Test Line artifacts tests Job Card ELE M034 - IQ Tools Mag Resolution Test on page 835 Job Card ELE M035 - IQ Tools Line Artifacts Test on page 839 If IQ Tests not OK, repeat all calibrations from Bad Pixel AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations Page no. 1295 JC-DR-A-243.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A243 - Compression Potentiometer and Cable This page is blank. Chapter 9 Page no. 1296 JC-DR-A-243.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A244 - Compression Motor with Encoder and Compression Belt Job Card D/R A244 - Compression Motor with Encoder and Compression Belt Chapter 9 1 SUPPLIES • • 1 Compression Motor 1 Compression Belt 2 • • • TOOLS Standard Tool Box Hub extractor Mammography compression scale with digital display 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 45 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 PREREQUISITES • Lower the arm until you have good access to the Compression Motor (1). • Switch off the Gantry power. • Remove the arm covers (refer to Job Card PHY A044 Remove/Reinstall Gantry Covers on page 523). 1 Page no. 1297 JC-DR-A-244.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A244 - Compression Motor with Encoder and Compression Belt 6 PROCEDURE 6-1 Disassembly of the Compression Belt 2 3 1. Remove the four screws (2) securing the Motor and its supporting plate (3 mm allen wrench). 2. Disengage the Belt (4) from the gears. 3. Remove the Belt. 6-2 Disassembly of the Compression Motor 1. Unplug the Motor cable W301 from the Compression Board (connector J3). 2. Remove the motor from its supporting plate, release the four screws (3) (3 mm allen wrench and 7 mm open ended 4 wrench). 3. Unplug the encoder cable W302 from the Compression Board (Connector J4). 4. Release the screw securing the gear and the motor (2 mm allen wrench). 5. Extract the gear with a hub extractor (and a 17 mm open-ended wrench). 6-3 • Reassembly of the Compression Motor and Belt Reverse the disassembly procedure and add the following step to the reassembly procedure: • Apply blue Loctite on the threads of the four screws securing the supporting plate and on the threads of the screw securing the motor and the gear before tightening them. • Check manually that the Belt is tight enough. 6-4 Check the Compression Movement 1. Check that both sets of compression/decompression pedals and the manual compression knobs located on the paddle holder all function correctly. That is, the paddle moves up or down in response to each control. 2. Use the mammography compression scale placed between the Bucky and the compression paddle to check calibration of the compression force display on the Gantry readout. Measure one point at 5 daN and one point at 15 daN. The value on the Gantry readout must agree within ±1 daN. If it does not, perform Job Card CAL A048 - Calibration of Compression Force Sensor on page 1709. Note: If the recommended compression measurement tool is not available, this verification can be done by lowering the paddle close to the top surface of the Bucky, installing the magnification device in the upper pair of holes, and connecting a spring dynamometer (calibrated from 0 kg to 15 kg) between the compression paddle and the magnification device. 7 COMPLETION None Chapter 9 Page no. 1298 JC-DR-A-244.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A245 - Manual Compression Belt Job Card D/R A245 - Manual Compression Belt 1 Chapter 9 SUPPLIES Manual Compression Belt 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 PREREQUISITES • Lower the arm to obtain good access to the Manual Compression Belt (1). • Switch off the Gantry power. • Remove the compression covers (Refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). 1 Page no. 1299 JC-DR-A-245.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A245 - Manual Compression Belt 6 PROCEDURE 6-1 Disassembly of the Manual Compression Belt 1. Release the two tension screws (2) (5 mm allen wrench). 4 3 5 6 2 2. Remove the spring clip (4) which secures the pulley (5) from the shaft (3). 3. Remove the pully from the shaft. Note: When removing the pulley (5) take great care not to lose the anti-rotation key (6), which locks it to the shaft. 4. Disengage and remove the Manual Compression Belt. 6-2 Reassembly of the Manual Compression Belt Reverse the disassembly procedure. • Check manually with your hands that the belt is sufficiently tight, that it does not slide, and that the pulleys move when the Manual Compression Belt moves. CAUTION During reassembly of the small pulley (5), double check that its anti-rotation key (6) and securing clip (4) are correctly set in place. If the key is absent or the belt slides from its position, manual compression functions and braking are not available. If there is a motorized compression failure patient injury is possible. 7 COMPLETION Check that the maximum applicable manual compression is between 27 daN and 30 daN. To do this, carry out the procedures described in Job Card ELE A017 - Manual Compression Check and Calibration on page 583. Chapter 9 Page no. 1300 JC-DR-A-245.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A246 - Manual Compression Brake Job Card D/R A246 - Manual Compression Brake 1 Chapter 9 SUPPLIES Manual Compression Brake 2 • • TOOLS Standard Tool Box Mammography compression scale with digital display 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 PREREQUISITES • Lower the arm to obtain good access to the Manual Compression Brake (1). • Switch off the Gantry power. • Remove the paddle. • Remove the compression covers (Refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). 1 Page no. 1301 JC-DR-A-246.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A246 - Manual Compression Brake 6 PROCEDURE 6-1 Disassembly of the Manual Compression Brake 1. Remove the belt (1) (refer to Job Card D/R A245 - Manual Compression Belt on page 1299). 1 2. Remove the M6 screw (2) (5 mm allen wrench). 2 3. Release the four pairs of M4 screws (3) (3 mm allen wrench). Then and carefully remove the Paddle Chapter 9 Page no. 1302 JC-DR-A-246.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A246 - Manual Compression Brake Holder (4) being sure not to brake the cables connected to the Paddle Holder board. 3 4 4. On the Paddle Holder board, carefully disconnect the Paddle Recognition cable from the J2 connector, Force Sensor cable from the J1 connector and Motor cable from the J2 connector. Disconnect the ground cable from the Paddle Holder. J1 : Force Sensor (J1 / PL304 - W304) J3 : Manual Compression Brake (J3 / PL304 - W314) J2 : Paddle Recognition Cable (J2 / PL304 - W319) Paddle Holder Earth Cable 5. Remove the four pairs of M4 screws (5) (3 mm allen wrench), and then remove the upper and lower Page no. 1303 JC-DR-A-246.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A246 - Manual Compression Brake parallel panel (6). 5 6 6. Release the M6 screw (7) and nut (8) (5 mm allen wrench), and remove the force sensor (9). 7 9 8 Chapter 9 Page no. 1304 JC-DR-A-246.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A246 - Manual Compression Brake 7. Release the M4 screw (10) (3 mm allen wrench) that secures the fixation ring (11). 12 13 10 11 8. Release the M5 set screw (12). 9. Pull out the Actuator axis (13). 10. Release the three M3 screws (14) fixing the compression brake (15) (2.5 mm allen wrench) and remove the compression brake (15). 14 15 Page no. 1305 JC-DR-A-246.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A246 - Manual Compression Brake 6-2 Reassembly of the Manual Compression Brake Reverse the disassembly procedure. • Add the following steps when reassembling the manual compression brake: - Insert a 0.2 mm feeler gauge as shown in the illustration: - Apply blue Loctite on the threads of the three screws securing the brake before tightening them. • Check manually with your hands that the belt is sufficiently tight, that it does not slide, and that the pulleys move when the Manual Compression Belt moves. CAUTION • If the belt slides from its position, manual compression functions and braking are not available. If there is a motorized compression failure, patient injury can occur. Take care to correctly route the cables as shown in the illustration below. Chapter 9 Page no. 1306 JC-DR-A-246.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A246 - Manual Compression Brake 6-3 Check the Compression Movement 1. Check that both sets of compression/decompression pedals and the manual compression knobs located on the paddle holder all function correctly. That is, the paddle moves up or down in response to each control. 2. Use the mammography compression scale placed between the Bucky and the compression paddle to check calibration of the compression force display on the Gantry readout. Measure one point at 5 daN and one point at 15 daN. The value on the Gantry readout must agree within ±1 daN. If it does not, perform Job Card CAL A048 - Calibration of Compression Force Sensor on page 1709. Note: If the recommended compression measurement tool is not available, this verification can be done by lowering the paddle close to the top surface of the Bucky, installing the magnification device in the upper pair of holes, and connecting a spring dynamometer (calibrated from 0 kg to 15 kg) between the compression paddle and the magnification device. 7 COMPLETION Check that the maximum applicable manual compression is between 27 daN and 30 daN. To do this, carry out the procedures described in Job Card ELE A017 - Manual Compression Check and Calibration on page 583. Page no. 1307 JC-DR-A-246.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A246 - Manual Compression Brake This page is blank. Chapter 9 Page no. 1308 JC-DR-A-246.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A247 - Motorized Compression Brake Job Card D/R A247 - Motorized Compression Brake 1 Chapter 9 SUPPLIES Motorized Compression Brake 2 • • TOOLS Standard Tool Box Mammography compression scale with digital display 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 45 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered on, mark it clearly with a warning sign to prevent others from applying commands. 5 • • • PREREQUISITES Rotate the arm to 90° for access to the Motorized Compression Brake (1). Switch off the Gantry power. Remove the Compression Arm covers (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). 1 View from the right of the Gantry Page no. 1309 JC-DR-A-247.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A247 - Motorized Compression Brake 6 PROCEDURE 6-1 Disassembly of the Motorized Compression Brake 1. Loosen the screw (2) on the top of the brake (2.5 mm allen wrench) 2 2. Disconnect the brake power supply cable (3) (W309) from the Compression Board (connector J5) 3. Connect the brake power supply cable (3) (W309) to the Arm Distribution Board (connector J5) in place of the previous cable (4) (disconnect W307). 3 Connect W309 Here 4 Compression Board Chapter 9 Arm Distribution Board Page no. 1310 JC-DR-A-247.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A247 - Motorized Compression Brake 4. Switch on the power because the brake must be supplied with continuous current for removal. 5. The brake is now free. Release the three screws (5) securing the motorized compression brake (2.5 mm allen wrench) and remove it gently to avoid losing the key (6). 6. Disconnect the power cable (W309) from the Arm Distribution Board (connector J5). 5 6-2 Reassembly of the Motorized Compression Brake • Reverse the disassembly procedure Remember to reconnect the brake supply cable W309 to J5 on the Compression Board and W307 to the Arm Distribution Board. Add the following steps when reassembling the motorized compression brake: Note: The brake must be supplied with continuous current for installation. • Insert a 0.2 mm feeler gauge (7) as shown in the following illustration: 6 • Apply blue Loctite to the threads of the three screws securing the brake before tightening them. Page no. 1311 JC-DR-A-247.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A247 - Motorized Compression Brake 6-3 Check the Compression Movement 1. Check that both sets of compression/decompression pedals and the manual compression knobs located on the paddle holder all function correctly. That is, the paddle moves up or down in response to each control. 2. Use the mammography compression scale placed between the Bucky and the compression paddle to check calibration of the compression force display on the Gantry readout. Measure one point at 5 daN and one point at 15 daN. The value on the Gantry readout must agree within ±1 daN. If it does not, perform Job Card CAL A048 - Calibration of Compression Force Sensor on page 1709. Note: If the recommended compression measurement tool is not available, this verification can be done by lowering the paddle close to the top surface of the Bucky, installing the magnification device in the upper pair of holes, and connecting a spring dynamometer (calibrated from 0 kg to 15 kg) between the compression paddle and the magnification device. 7 COMPLETION None Chapter 9 Page no. 1312 JC-DR-A-247.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A248 - Force Sensor Job Card D/R A248 - Force Sensor 1 Chapter 9 SUPPLIES Force Sensor 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 60 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 • • • PREREQUISITES Switch off the Gantry power. Remove the Paddle. Remove the Paddle Holder cover (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523) for access to the Force Sensor (1) 1 Page no. 1313 JC-DR-A-248.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A248 - Force Sensor 6 PROCEDURE 6-1 Disassembly of the Force Sensor 1. Remove the M6 screw (1) (5 mm allen wrench). 1 2. Release the four pairs of M4 screws (2) (3 mm allen wrench), and remove the Paddle Holder (3). 2 3 3. On the Paddle Holder board, carefully disconnect the Paddle Recognition cable from the J2 connector, Force Sensor cable from the J1 connector and Motor cable from the J2 connector. Disconnect Chapter 9 Page no. 1314 JC-DR-A-248.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A248 - Force Sensor the ground cable from the Paddle Holder. J1 : Force Sensor (J1 / PL304 - W304) J3 : Manual Compression Brake (J3 / PL304 - W314) J2 : Paddle Recognition Cable (J2 / PL304 - W319) Paddle Holder Earth Cable 4. Remove the four pairs of M4 screws (4) (3 mm allen wrench), and then remove the upper and lower parallel bar (5). 4 5 Page no. 1315 JC-DR-A-248.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A248 - Force Sensor 5. Release the M6 screw (6) and nut (7) (5 mm allen wrench), and remove the force sensor (8). 6 8 7 Chapter 9 Page no. 1316 JC-DR-A-248.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A248 - Force Sensor 6-2 • Reassembly of the Force Sensor Reverse the disassembly procedure, however at this stage do not reinstall the Padle Holder cover. CAUTION • Take care to install the new Force Sensor in its original position (not inverted). Take care to correctly route the cables as shown in the illustration below. 6-3 Paddle Holder Board DIP Switch Setting If the Senographe system contains a Paddle Holder Board (2369391-2) with DIP switches (see illustration below), set the DIP switches as detailed below. DIP Switch OFF ON 1 2 3 4 Page no. 1317 JC-DR-A-248.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A248 - Force Sensor Set DIP switch 4 to ON and DIP switches 1, 2, 3 to OFF. When the Paddle Holder is reassembled but before installing covers, install a standard compression paddle. 1. Power on the Gantry and see if yellow LED DS2 next to the DIP switches is illuminated. • If DS2 is NOT illuminated, the correct DIP switch setting has been found, and this procedure is complete. • If DS2 is illuminated, power off the Gantry and set DIP switch 2 to ON and DIP switches 1, 3, 4 to OFF, then go step 2. 2. Power on the Gantry and see if DS2 is illuminated. • If DS2 is NOT illuminated, the correct DIP switch setting has been found, and this procedure is complete. • If DS2 is still illuminated, power off Gantry and set DIP switch 1 to ON and DIP switches 2, 3, 4 to OFF, then go step 3. 3. Power on the Gantry and see if DS2 is illuminated. • If DS2 is NOT illuminated the correct DIP switch setting has been found, and this procedure is complete. • If DS2 is still illuminated the Paddle Holder Board is probably faulty or possibly the newly installed Force Sensor is faulty. TIP: use a 1.5 mm allen key or a similar small object to set the DIP switch positions. Note: When red LED DS3 next to the connector J1 is illuminated it indicates that Force Sensor is wire disconnected or that the Force Sensor needs changing. 4. Once the Paddle Holder Board DIP switches are set as required, reinstall the Paddle Holder cover (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). 6-4 Check the Compression Movement Check that both sets of compression/decompression pedals and the manual compression knobs located on the paddle holder all function correctly. That is, the paddle moves up or down in response to each control. 7 COMPLETION Carry out the following calibration procedures: Calibrations - Checks Job Card Gantry Compression Force Sensor Job Card CAL A048 - Calibration of Compression Force Sensor on page 1709 Compression Thickness Job Card CAL A050 - Compression Thickness Calibration on page 1721 If Compression Thickness not OK, repeat calibrations from Compression Force Sensor AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations Chapter 9 Page no. 1318 JC-DR-A-248.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A249 - W304 Cable for Paddle Recognition Job Card D/R A249 - W304 Cable for Paddle Recognition 1 Chapter 9 SUPPLIES W304 Cable for Paddle Recognition 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 60 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 • • • PREREQUISITES Switch off the Gantry power. Remove the Paddle. Remove the Paddle Holder cover (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523) for access to the Paddle Recognition cable. Page no. 1319 JC-DR-A-249.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A249 - W304 Cable for Paddle Recognition 6 PROCEDURE 6-1 Disassembly of the Paddle Recognition Cable 1. Remove the M6 screw (1) (5 mm allen wrench). 1 2. Release the four pairs of M4 screws (2) (3 mm allen wrench), and remove the Paddle Holder (3). 2 3 3. On the Paddle Holder board, carefully disconnect the Paddle Recognition cable from the J2 connector, Force Sensor cable from the J1 connector and Motor cable from the J2 connector. Disconnect Chapter 9 Page no. 1320 JC-DR-A-249.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A249 - W304 Cable for Paddle Recognition the ground cable from the Paddle Holder. J1 : Force Sensor (J1 / PL304 - W304) J3 : Manual Compression Brake (J3 / PL304 - W314) J2 : Paddle Recognition Cable (J2 / PL304 - W319) Paddle Holder Earth Cable 4. Taking care not to damage the earth cable, cut the cable ties (4) that secure the Paddle Recognition cable to the side of the Compression Arm framework.. 4 6 5 5. Carefully disconnect the D-connector (5) of the Paddle Recognition cable from the cable that leads to the D-Connector (6) of the cable leading to the Compression Board. Page no. 1321 JC-DR-A-249.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A249 - W304 Cable for Paddle Recognition 6-2 Reassembly of the Paddle Recognition Cable Reverse the disassembly procedure. Take care to correctly route the cables as shown in the illustration below. 6-3 Check the Compression Movement Check that both sets of compression/decompression pedals and the manual compression knobs located on the paddle holder all function correctly. That is, the paddle moves up or down in response to each control. 7 COMPLETION None. Chapter 9 Page no. 1322 JC-DR-A-249.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A250 - Compression Board Job Card D/R A250 - Compression Board 1 Chapter 9 SUPPLIES Compression Board 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 40 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 • • PREREQUISITES Switch off the Gantry power. Remove the Compression arm covers (Refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523) to access the Compression Board (1). 1 Page no. 1323 JC-DR-A-250.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A250 - Compression Board 6 PROCEDURE 6-1 Disassembly of the Compression Board 1. Carefully disconnect all cables from the Compression board. Ensure that you do not move them too much so it is easier to re-connect them later on. 2 2. Remove the four screws (2) securing the Compression board (2.5 mm allen wrench). 3. Remove the Compression Board. 6-2 Reassembly of the Compression Board 1. Carefully place the new Compression board in position and secure it using the four screws (2.5 mm allen wrench). CAUTION Ensure that you do not pinch the cables that are in close proximity to the Compression board. 2. Connect all the cables to the new Compression board as summarized in the diagram and table below. Chapter 9 Page no. 1324 JC-DR-A-250.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A250 - Compression Board J5 J3 J1 J8 J7 J6 J4 J9 J10 J2 Page no. 1325 JC-DR-A-250.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A250 - Compression Board Connector Label Description of cable (usually identified by code on a yellow label) Cable color J1 J1/PL303-W307 Gray J2 J2/PL303-W308 Gray J3 J3/PL301-W301 Red, Blue, Orange, Yellow J4 J4/PL301-W302 Gray ribbon J5 J4/PL303-W309 covered with flexible plastic Red/Green Blue/Green J6 J6/PL303-W303 Black, Red, Green J7 J7/PL303-W305 Note: Only connected when replacing the covers. Light brown ribbon J8 J8/PL303-W305 Note: Only connected when replacing the covers. Light brown ribbon J9 J9/PL303-W313 Grey robbon J10 J7/PL303-W304 Gray J21 Empty N/A J22 Empty N/A 3. Ensure that jumper JP1 (3) that is to the left of the J6 connector on the Compression board is open. 3 Chapter 9 Page no. 1326 JC-DR-A-250.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A250 - Compression Board 6-3 • • Check Cable Positioning The cables around the Compression board must be carefully positioned to avoid possible damage when installing or removing covers. Ensure that all cables are positioned and secured as shown below: 1 Use cable ties to secure cables W303 and W304 together. Use cable ties to secure cables W302 and W308 together. Cable W302 must pass in front of the board as shown. In order to avoid EMC interference, use cable ties to ensure that the W303 and W304 cables pass around the Compression Board. Use cable ties to secure cable W313 to the board spacers. 2 October 2007 Systems and later Pre October 2007 Systems Pass the cables cables W303 and W304 above the board through the indicated cut-out. Use a cable tie to secure cables W301, W303, and W304 above the board. OR • To avoid electromagnetic interference, ensure that the cables W303 and W304 do not pass over the microprocessor that is located in the center of the Compression board. Page no. 1327 JC-DR-A-250.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A250 - Compression Board 6-4 • • Observation LED Checks Power on the Gantry and check that no errors are raised on the Gantry LCD display. Check that the LED states are as follows. For more information about the behavior and states of the Compression board LEDs, refer to Stepper Board on page 288. Chapter 9 LED Label LED Color LED Status DS1 Green ON DS2 Green ON DS3 Yellow ON DS4 Yelllow ON DS5 Green ON DS6 Yellow OFF DS7 Green ON or OFF DS8 Yellow ON DS9 Green ON DS10 Red Blinking Page no. 1328 JC-DR-A-250.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A250 - Compression Board 7 COMPLETION 7-1 Firmware Check Check whether the new Compression Board firmware needs to be updated, as follows: 1. Reboot the Senographe system. 2. Go to the Service Desktop home page (see Launching the Service Desktop on page 120). 3. Consult Table 1 on page 63 in the section Component FW/SW to ADS Version compatibility Matrix on page 63. Determine the system level from the ADS/IDC/Generator CPU versions displayed on the Service Desktop home page, and by consulting Table 1 on page 63. The system level will be defined by one of the System Level (Model Number) columns in Table 1 on page 63. 4. Check whether the current firmware version(s) for the new Compression Board corresponds to the required firmware version for the that system level. • If the current firmware version(s) match the required version(s) quoted in Table 1 on page 63, no additional steps are required. • If the current firmware version(s) does not match the required version(s), you must perform a firmware update of the mismatched firmware version(s) so that the new Compression Board firmware version(s) match those quoted in Table 1 on page 63. To update the new Compression Board firmware follow the instructions supplied in the Gantry Software Update CD-ROM that is kept with the system. 7-2 • • Calibrations Check compression motion and keypad. Carry out the following calibration (and verification) procedures: Calibrations - Checks Job Card Gantry Compression Force Sensor Calibration Compression Force Calibration on page 1709 in Job Card CAL A048 - Calibration of Compression Force Sensor Compression Thickness Calibration Compression Thickness Calibration on page 1721 in Job Card CAL A050 - Compression Thickness Calibration Compression Force Calibration Verification Verification of the Compression Force Sensor calibration on page 1710 in Job Card CAL A048 - Calibration of Compression Force Sensor Compression Thickness Calibration Verification Check the Thickness Measurement in Contact Mode on page 1722 in Job Card CAL A050 - Compression Thickness Calibration If Compression Thickness not OK, repeat calibrations from Compression Force Sensor AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations Page no. 1329 JC-DR-A-250.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A250 - Compression Board This page is blank. Chapter 9 Page no. 1330 JC-DR-A-250.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A251 - Paddle Holder Board Job Card D/R A251 - Paddle Holder Board 1 Chapter 9 SUPPLIES Determine whether you have a Paddle Holder Board with or without DIP switches. To do this, remove the Paddle Holder Cover and view the left hand side of the Paddle Holder Block where the earth cable is connected (see below). Without DIP switches With DIP switches Order the appropriate Paddle Holder Board according to the type already present in the Gantry. • Paddle Holder Board (PN 2369391) if the existing Paddle Holder Board does not have a set of DIP switches. • Paddle Holder Board (PN2369391-2) if the existing Paddle Holder Board does have a set of DIP switches. 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. Page no. 1331 JC-DR-A-251.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A251 - Paddle Holder Board 5 • • • PREREQUISITES Switch off the Gantry power. Remove the Paddle. Remove the Paddle Holder cover (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523) to access the Paddle Holder Board (1). 1 Chapter 9 Page no. 1332 JC-DR-A-251.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A251 - Paddle Holder Board 6 PROCEDURE 6-1 Disassembly of the Paddle Holder Board 1. Remove the M6 screw (1) (5 mm allen wrench). 1 2. Release the four pairs of M4 screws (2) (3 mm allen wrench), and remove the Paddle Holder (3). 2 3 3. On the Paddle Holder board, carefully disconnect the Paddle Recognition cable from the J2 connector, Force Sensor cable from the J1 connector and Motor cable from the J2 connector. Disconnect Page no. 1333 JC-DR-A-251.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A251 - Paddle Holder Board the ground cable from the Paddle Holder. J1 : Force Sensor (J1 / PL304 - W304) J3 : Manual Compression Brake (J3 / PL304 - W314) J2 : Paddle Recognition Cable (J2 / PL304 - W319) Paddle Holder Earth Cable 4. 5. Remove the four M4 screws (4) (5 mm allen wrench). 4 5 6. Remove the Paddle Holder Board (5). Chapter 9 Page no. 1334 JC-DR-A-251.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A251 - Paddle Holder Board 6-2 • • Reassembly of the Paddle Holder Board Reverse the disassembly procedure, however at this stage do not reinstall the Padle Holder cover. Take care to correctly route the cables as shown in the illustration below. 6-3 Paddle Holder Board DIP Switch Setting If you changed the Paddle Holder Board with a Paddle Holder Board (2369391-2) with DIP switches (see illustration below), set the DIP switches as detailed below. DIP Switch OFF ON 1 2 3 4 If you changed Paddle Holder Board 2369391-2 with another 2369391-2, set the DIP switches of the new Paddle Holder Board to the same position as old Paddle Holder Board. Page no. 1335 JC-DR-A-251.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A251 - Paddle Holder Board If you changed Paddle Holder Board 2359391 with 2369391-2, set DIP switch 4 to ON and DIP switches 1, 2, 3 to OFF. When the Paddle Holder is reassembled but before installing covers, install a standard compression paddle. 1. Power on the Gantry and see if yellow LED DS2 next to the DIP switches is illuminated. • If DS2 is NOT illuminated, the correct DIP switch setting has been found, and this procedure is complete. • If DS2 is illuminated, power off the Gantry and set DIP switch 2 to ON and DIP switches 1, 3, 4 to OFF, then go step 2. 2. Power on the Gantry and see if DS2 is illuminated. • If DS2 is NOT illuminated, the correct DIP switch setting has been found, and this procedure is complete. • If DS2 is still illuminated, power off Gantry and set DIP switch 1 to ON and DIP switches 2, 3, 4 to OFF, then go step 3. 3. Power on the Gantry and see if DS2 is illuminated. • If DS2 is NOT illuminated the correct DIP switch setting has been found, and this procedure is complete. • If DS2 is still illuminated the Force Sensor is probably faulty or possibly the newly installed Paddle Holder Board is faulty. TIP: use a 1.5 mm allen key or a similar small object to set the DIP switch positions. Note: When red LED DS3 next to the connector J1 is illuminated it indicates that Force Sensor is wire disconnected or that the Force Sensor needs changing. 4. Once the Paddle Holder Board DIP switches are set as required, reinstall the Paddle Holder cover (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). 7 COMPLETION Carry out the following calibration procedures: Calibrations - Checks Job Card Gantry Compression Force Sensor Job Card CAL A048 - Calibration of Compression Force Sensor on page 1709 Compression Thickness Job Card CAL A050 - Compression Thickness Calibration on page 1721 If Compression Thickness not OK, repeat calibrations from Compression Force Sensor AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations Chapter 9 Page no. 1336 JC-DR-A-251.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job card D/R A252 - Compression Trolley Kit Job card D/R A252 - Compression Trolley Kit 1 Chapter 9 SUPPLIES Compression Trolley Kit (comprising Paddle Holder, and W304B Cable) 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 • 6 PREREQUISITES Switch off the Gantry power. PROCEDURE 1. Remove the Compression Carriage covers (refer to section 8-1 in Job Card PHY A044 - Remove/ Reinstall Gantry Covers on page 523). 2. Remove the Compression trolley (refer to section 8-2 in Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). 3. Change the old Compression trolley for a new Compression trolley (refer to section 8-2 in Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). 4. Replace the original Compression Carriage covers (refer to section 8-1 in Job Card PHY A044 Remove/Reinstall Gantry Covers on page 523). Page no. 1337 JC-DR-A-252.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job card D/R A252 - Compression Trolley Kit 7 • • COMPLETION Check compression motion and keypad. Carry out the following calibration procedures: : Calibrations - Checks Job Card Gantry Compression Force Sensor Job Card CAL A048 - Calibration of Compression Force Sensor on page 1709 Compression Thickness Job Card CAL A050 - Compression Thickness Calibration on page 1721 If Compression Thickness not OK, repeat calibrations from Compression Force Sensor AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations Chapter 9 Page no. 1338 JC-DR-A-252.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A255 - Bucky Job Card D/R A255 - Bucky 1 Chapter 9 SUPPLIES Bucky 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 35 minutes 4 SAFETY PRECAUTIONS Not applicable 5 PREREQUISITES Before installing the new Bucky, make sure that the Bucky is placed for at least 30 minutes in a dry room whose temperature is greater than or equal to 20°C (68°F). ! Notice: Never put the Bucky onto a hot surface to speed up this process. 6 PROCEDURE 6-1 Principle Bad repositioning of the Bucky during gain calibration or during acquisitions result in vertical artifacts on the image (perpendicular to the grid lines). The correct Bucky position is ensured by the proper tightening of the two latches, one each side of the Bucky. 6-2 Installation of New Bucky To ensure a correct positioning of the Bucky, the following procedure must be followed: Page no. 1339 JC-DR-A-255.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A255 - Bucky 1. Adjust the latch on the Detector side: - Release the two screws Tighten the screws while pushing the latch securing plate firmly in the direction of the chest wall. 2. Adjust the latch on the Bucky side 6-3 - Release the two screws - Tighten the screws while pushing the latch securing plate firmly in the chest wall direction, and ensuring that it is aligned with the one on the detector side. Verification Check that when the latches are tightened, the Bucky is in contact with the back plate of the detector on both sides. Chapter 9 Page no. 1340 JC-DR-A-255.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A255 - Bucky 7 COMPLETION 7-1 Firmware Check Check whether the Bucky Board firmware in the new Bucky needs to be updated, as follows: 1. Reboot the Senographe system. 2. Go to the Service Desktop home page (see Launching the Service Desktop on page 120). 3. Consult Table 1 on page 63 in the section Component FW/SW to ADS Version compatibility Matrix on page 63. Determine the system level from the ADS/IDC/Generator CPU versions displayed on the Service Desktop home page, and by consulting Table 1 on page 63. The system level will be defined by one of the System Level (Model Number) columns in Table 1 on page 63. 4. Check whether the current firmware version(s) for the new Bucky Board in the new Bucky corresponds to the required firmware version for the that system level. • If the current firmware version(s) match the required version(s) quoted in Table 1 on page 63, no additional steps are required. • If the current firmware version(s) does not match the required version(s), you must perform a firmware update of the mismatched firmware version(s) so that the new PDU Board firmware version(s) match those quoted in Table 1 on page 63. To update the new PDU Board firmware follow the instructions supplied in the Gantry Software Update CD-ROM that is kept with the system. 7-2 Calibrations Carry out the procedures: Calibrations - Checks Job Card Gantry Mechanical thickness check Job Card ELE A015 - Gantry Functional Checks on page 579 § 6-9 Acquisition Image Chain Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697, grid configurations only flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699, grid configurations only If IQ Test(s) not OK, repeat Gain Calibration. Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 AOP: Automatic Optimization of Parameters AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations from AOP Calibration Page no. 1341 JC-DR-A-255.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A255 - Bucky This page is blank. Chapter 9 Page no. 1342 JC-DR-A-255.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job card D/R A256 - Bucky Top Cover Job card D/R A256 - Bucky Top Cover 1 Chapter 9 SUPPLIES Bucky Top Cover 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 20 minutes 4 SAFETY PRECAUTIONS Not applicable 5 PREREQUISITES None 6 PROCEDURE 6-1 Disassembly of the Bucky Top Cover 1. Remove the three screws and brass blocks (1) (cross-head screwdriver) which secure the top cover to the Bucky. Ensure that you access the two side screws by the hole (2) in the Bucky framework. 1 2 Note: The Bucky illustrated has three brass blocks. Earlier versions of the bucky may miss the central brass block, which is replaced by a brass washer. Page no. 1343 JC-DR-A-256.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job card D/R A256 - Bucky Top Cover 2. Gently lift the old top cover (3) from the back of the Bucky to expose the interior components of the Bucky. 3 3. Gently slide the old top cover towards the back of the Bucky away from the carbon surface to fully remove it from the Bucky. CAUTION The interior components of the Bucky are extremely delicate, and contain electrical and moving parts. Pay special attention not to touch Bucky’s interior components when you fully remove the top cover. Chapter 9 Page no. 1344 JC-DR-A-256.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job card D/R A256 - Bucky Top Cover 6-2 Reassembly of the new Bucky Top Cover 1. Gently slide the new top cover (1) towards the Bucky’s carbon surface so that it slots above and below the carbon surface. 1 CAUTION The interior components of the Bucky are extremely delicate, and contain electrical and moving parts. Pay special attention not to touch Bucky’s interior components slide the new top cover into place. 2. Gently lower the top cover down towards the back of the Bucky to hide the Bucky’s interior components. When lowering the top cover onto the back of the Bucky, ensure that each side (2) of the top cover passes cleanly by the bolt (3) located on each side of the Bucky’s framework. 2 3 Page no. 1345 JC-DR-A-256.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job card D/R A256 - Bucky Top Cover 3. Examine the positioning of the new top cover as follows: a. Ensure each of the new top cover’s sides are firmly in place. b. Ensure that the back of the new top cover fits firmly in the Bucky’s framework and that there is equidistant space between the top cover and the Bucky. 4. Attach the three screws and brass blocks (4) (cross-head screwdriver) to secure the top cover to the Bucky. Ensure that you access the two side screws by the hole (5) in the Bucky framework. 4 5 ! Notice: Be careful not to overtighten the screws on the three plastic threaded studes of the Bucky. If you overtighten the screws you could break the new Bucky top cover. 7 COMPLETION None. Chapter 9 Page no. 1346 JC-DR-A-256.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job card D/R A258 - Bucky Board Job card D/R A258 - Bucky Board 1 Chapter 9 SUPPLIES Bucky Board 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 20 minutes 4 SAFETY PRECAUTIONS Not applicable 5 PREREQUISITES None 6 PROCEDURE 6-1 Disassembly of the Bucky Top Cover 1. Remove the three screws and brass blocks (1) (cross-head screwdriver) which secure the top cover to the Bucky. Ensure that you access the two side screws by the hole (2) in the Bucky framework. 1 2 Note: The Bucky illustrated has three brass blocks. Earlier versions of the bucky may miss the central brass block, which is replaced by a brass washer. Page no. 1347 JC-DR-A-258.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job card D/R A258 - Bucky Board 2. Gently lift the old top cover (3) from the back of the Bucky to expose the interior components of the Bucky. 3 3. Gently slide the old top cover towards the back of the Bucky away from the carbon surface to fully remove it from the Bucky. Note: The interior components of the Bucky are extremely delicate, and contain electrical and moving parts. Pay special attention not to touch Bucky interior components when you fully remove the top cover. 6-2 Change the Bucky Board 1. Carefully disconnect the Bucky connector cables (1 and 2) and Bucky motor cable (3) from the Bucky board. 4 4 2 5 1 3 4 4 Note: The connectors on the Bucky connector cable and Bucky motor cable are fragile. Ensure you take care not to break them when removing them from the Bucky board. 2. Discconnect the four allen screws and washers (4) that secure the Bucky board to the Bucky (2.5 mm Chapter 9 Page no. 1348 JC-DR-A-258.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job card D/R A258 - Bucky Board 3. 4. 5. 6. allen wrench). Remove the faulty Bucky board by carefully sliding it upwards to the lefthand side away from the Bucky, being careful not to damage the metal arm (5) connected to the Bucky. Insert the new Bucky board from the left hand side, by carefully sliding it downwards to into the Bucky. When inserting the Bucky board be careful to ensure that the metal arm (5) connected to the Bucky passes in between the optical fork on the Bucky board. Use the four allen screws and washers (4) secure the Bucky board to the Bucky (2.5 mm allen wrench). Carefully connect the Bucky connector cables (1 and 2) and Bucky motor cable (3) to the new Bucky board. Note: The connectors on the Bucky connector cable and Bucky motor cable are fragile. Ensure you take care not to break them when connecting them to the new Bucky board. Page no. 1349 JC-DR-A-258.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job card D/R A258 - Bucky Board 6-3 Reassembly of the new Bucky Top Cover 1. Gently slide the top cover (1) towards the Bucky carbon surface so that it slots above and below the carbon surface. 1 ! Notice: The interior components of the Bucky are extremely delicate, and contain electrical and moving parts. Pay special attention not to touch Bucky interior components while sliding the top cover into place. 2. Gently lower the top cover down towards the back of the Bucky to hide the Bucky interior components. When lowering the top cover onto the back of the Bucky, ensure that each side (2) of the top cover passes cleanly by the bolt (3) located on each side of the Bucky’s framework. 2 3 Chapter 9 Page no. 1350 JC-DR-A-258.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job card D/R A258 - Bucky Board 3. Examine the positioning of the new top cover as follows: a. Ensure each of the new top cover’s sides are firmly in place. b. Ensure that the back of the new top cover fits firmly in the Bucky framework and that there is equidistant space between the top cover and the Bucky. 4. Attach the three screws and brass blocks (4) (cross-head screwdriver) to secure the top cover to the Bucky. Ensure that you access the two side screws by the hole (5) in the Bucky framework. 4 5 ! Notice: Be careful not to overtighten the screws on the three plastic threaded studes of the Bucky. If you overtighten the screws you could break the new Bucky top cover. Page no. 1351 JC-DR-A-258.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job card D/R A258 - Bucky Board 7 COMPLETION 7-1 Firmware Check Check whether the new Bucky Board firmware needs to be updated, as follows: 1. Reboot the Senographe system. 2. Install the Bucky on the Digital Detector, and ensure its locked into place. 3. Go to the Service Desktop home page (see Launching the Service Desktop on page 120). 4. Consult Table 1 on page 63 in the section Component FW/SW to ADS Version compatibility Matrix on page 63. Determine the system level from the ADS/IDC/Generator CPU versions displayed on the Service Desktop home page, and by consulting Table 1 on page 63. The system level will be defined by one of the System Level (Model Number) columns in Table 1 on page 63. 5. Check whether the current HC12 firmware version for the new Bucky Board corresponds to the required firmware version for the that system level. • If the current HC12 firmware version matches the required version quoted in Table 1 on page 63, no additional steps are required. • If the current HC12 firmware version does not match the required version, you must perform a firmware update of the mismatched HC12 firmware version so that the new Bucky Board HC12 firmware version matches that quoted in Table 1 on page 63. To update the new Bucky Board firmware follow the instructions supplied in the Gantry Software Update CD-ROM that is kept with the system. Chapter 9 Page no. 1352 JC-DR-A-258.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A261 - X-ray Tube Assembly Job Card D/R A261 - X-ray Tube Assembly 1 • • Chapter 9 SUPPLIES X-ray tube assembly Silicone Lubricant which is supplied with the X-ray tube assembly 2 • • TOOLS Standard Tool Box Trolley 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 4 to 5 hours including all calibrations and functional checks 4 SAFETY PRECAUTIONS WARNING Be careful when touching the tube housing, as its temperature can be up to 80°C (about 180°F). 5 • • • • PREREQUISITES Select Aluminium filter (to avoid possible damage to rhodium or molybdenum filters). Rotate the arm to 90° to access the X-ray Tube. Switch off the Gantry power. Remove the tube cover (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). Remove the tilt motor and drive assembly (refer to Job Card D/R A265 - Tilt Motor and Drive Assembly on page 1361). • 6 PROCEDURE ! Notice: Take great care to avoid damage to the rhodium filter, since it is expensive. Page no. 1353 JC-DR-A-261.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A261 - X-ray Tube Assembly 6-1 Removal of X-ray Tube Housing 1. Release and remove the four screws securing the upper spacer (1) (4 mm allen wrench). 2. Release and remove the screws (2) securing the tilt assembly (5 mm allen wrench). 2 1 CAUTION Before proceeding, ensure that the arm is horizontal, and that the tube assembly is supported so that it does not fall when the pivots are removed. 3 3. Remove the pivots (3) on both sides: • Release and remove the two screws securing the right pivot (2 mm allen wrench). • Release and remove the three screws securing the left pivot (2 mm allen wrench). • Pull out and remove the pivots. The pivots are tapped (x mm thread) so that a screw can be inserted and used to pull the pivot out of its housing. 4. Remove housing by gently pulling out the tube head, interface plate, and filter wheel ( all together) and place them on a suitable trolley. The X-ray tube must be held by the HV female connector, and not by the HV cable. 5. Release and remove the two screws securing the filter wheel to the interface plate. CAUTION Do not touch the molybdenum and rhodium filters with fingers. 6. Release and remove the two screws securing the interface plate to the tube head. 7. Disconnect the HT connector (5) from the housing. 8. Disconnect the stator cable connector (4). 9. Remove one ground cable (6) from the grounding points. 10. On the Interface board PL104, unplug cable W402 (connector J4). 4 5 6 Chapter 9 Page no. 1354 JC-DR-A-261.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A261 - X-ray Tube Assembly 6-2 Installation of X-ray Tube Housing When you install the new X-ray Tube Housing you must ensure that tube is mounted without any extra horizontal play. To do this proceed as follows: 1. Rotate the tube to the left (CCW) 90° so that the tube you will install can rest naturally on the fixed brass fitting. 2. On the Interface board PL104, plug cable W402 5 4 (connector J4). 3. Reconnect the ground cable (6) to the grounding points. 4. Reconnect the stator cable connector (4). 5. Reconnect the HT connector (5) to the housing. 6. Re-attach the two screws to securing the interface plate to the new tube head. CAUTION Do not touch the molybdenum and rhodium 6 filters with fingers. 7. Re-attach the two screws securing the filter wheel to the interface plate. 8. Carefully replace the newly constructed housing. 2 1 9. Reattach the pivots (3) on both sides. • Re-attach the left pivot so it is flush against the housing and tighten the three screws to secure it. • Re-attach and push down firmly on the right pivot to ensure a tight fit. • CAUTION: Failure to do this can create a gap that causes the tube to shift laterally during arm rotation. The resultant X-ray beam shift can show up as inter3 mittent lateral collimator blade cut-off on images. 10. Re-attach the screws (2) to securing the tilt assembly (5 mm allen wrench). 11. Re-attach the four screws to secure the upper spacer (1) (4 mm allen wrench). 12. The HT connector must be lightly coated with silicone lubricant to facilitate easy and full insertion. It is not used for HV insulation, only as a lubricant. WARNING You must use the silicone lubricant that is supplied with the new X-ray tube. If you use any other type of lubricant such as HV grease it will destroy the HT connector. Page no. 1355 JC-DR-A-261.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A261 - X-ray Tube Assembly 7 COMPLETION 1. Disconnect connector J4 from board PL104 and check that the message: TUBE HOUSING OVER TEMPERATURE appears on the control panel. 2. Reconnect connector J4 and check that the message disappears. 3. Rotate the arm +/-90 degrees several times to ensure that the new tube is not shifting, then rotate the arm back to 0 degrees. 4. Before proceeding with the calibrations and checks as specified below, perform a Clear Calibrations operation. From the Service Desktop, click the Calibrations button, then select Detector, and Clear Calibration. 5. Carry out the following calibrations: Calibrations - Checks Job Card Acquisition Image Chain Bias Calibration Job Card CAL A003 - X-Ray Tube Focal Bias Voltage Scale Factor on page 1655 Heating Current Calibration Job Card CAL A001 - Heater Current Scale Factor on page 1649 mAs X-ray Calibration Job Card CAL A012 - X-Ray Tube Heater Current on page 1673 Tube Tilt Calibration Job Card CAL A027 - Tube Tilt Calibration on page 1681 Collimator Calibration Job Card CAL A029 - Collimator Format Calibration on page 1683 Collimation Check Job Card ELE A028 - Collimation Checks on page 679 If Collimation Check not OK, repeat Collimator Calibration Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 If IQ Tests not OK, repeat all calibrations from Bad Pixel. Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Use the same dosimeter as that used for CAL A046 AOP: Automatic Optimization of Parameters AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations from AOP Calibration Chapter 9 Page no. 1356 JC-DR-A-261.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A264 - Tilt Sensor Job Card D/R A264 - Tilt Sensor 1 Chapter 9 SUPPLIES Zero Tilt Sensor and Cable W405 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 2 hours 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 • • • PREREQUISITES Rotate the arm to 90° for access to the Tilt Sensor (1). Switch off the Gantry power. Remove the tube cover (refer to Job Card PHY A044 Remove/Reinstall Gantry Covers on page 523). 1 Page no. 1357 JC-DR-A-264.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A264 - Tilt Sensor 6 PROCEDURE 6-1 Disassembly of the Tilt Sensor 1. Unplug the Tilt Motor cable (W404) from the tilt board (connector J3). 3 2. Unplug the Tilt Sensor cable (W405) from the tilt board (connector J12). 3. Cut the two cable ties. 2 4. Remove the four screws (2) securing the upper spacer (4 mm allen wrench). 5. Remove the two screws (3) securing the Tilt Motor assembly (5 mm allen wrench). 6. Tilt the assembly manually from the top to extract the coupling pin (4) from its fork (5) and remove the assembly. 5 Chapter 9 4 Page no. 1358 JC-DR-A-264.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A264 - Tilt Sensor 7. Remove the two screws (7) securing the Tilt Sensor (6) (2.5 mm allen wrench). 8. Remove the Tilt Sensor. 7 6-2 • 7 6 Reassembly of the Tilt Sensor Reverse the disassembly procedure. COMPLETION Carry out the following calibrations: Calibrations - Checks Job Card Acquisition Image Chain Tube Tilt Calibration Job Card CAL A027 - Tube Tilt Calibration on page 1681 Collimator Calibration Job Card CAL A029 - Collimator Format Calibration on page 1683 Collimation Check Job Card ELE A028 - Collimation Checks on page 679 If Collimation Check not OK, repeat Collimator Calibration. Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 If IQ Tests not OK, repeat all calibrations from Bad Pixel. Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Use the same dosimeter as that used for CAL A046 AOP: Automatic Optimization of Parameters AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations from AOP Calibration. Page no. 1359 JC-DR-A-264.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A264 - Tilt Sensor This page is blank. Chapter 9 Page no. 1360 JC-DR-A-264.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A265 - Tilt Motor and Drive Assembly Job Card D/R A265 - Tilt Motor and Drive Assembly 1 Chapter 9 SUPPLIES Entire Tilt Motor and Tilt Drive Assembly with Bearing (2345905) Or separately, as required: • Motor-Tilt + W404 (2345929) • Tilt Drive Assembly (2392469) • Bearing-Tilt Drive (99033678) 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 2 hours 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 • • • PREREQUISITES Rotate the arm to 90° for access to the Tilt Motor (1). Switch off the Gantry power. Remove the tube cover (refer to Job Card PHY A044 Remove/Reinstall Gantry Covers on page 523). 1 Page no. 1361 JC-DR-A-265.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A265 - Tilt Motor and Drive Assembly 6 PROCEDURE 6-1 Disassembly of the Tilt Motor and Drive Assembly To remove the assembly: 1. Unplug the Tilt motor cable (W404) from the tilt board (connector J3). 3 2. Unplug the Tilt sensor cable (W405) from the tilt board (connector J12). 2 3. Remove the four screws (2) securing the upper spacer (4 mm allen wrench). 4. Remove the two screws (3) securing the Tilt Motor assembly (5 mm allen wrench). 5. Tilt the assembly manually from top to extract the coupling pin (4) from its fork (5) and remove the assembly. If it is not necessary to change components within the assembly, the procedure is complete. 7 Chapter 9 4 5 To remove components from the assembly: 1. Release the motor coupling screw (6) (1.5 mm allen wrench) 2. Remove the four screws (7) securing the motor (2.5 mm allen wrench). 3. Remove the Tilt Motor with half of the coupling. 4. If changing the motor, loosen the screw securing the coupling to the motor (1.5 mm allen wrench) and remove the coupling. 5. Remove the Tilt Drive Assembly (8) and Tilt Drive Bearing (9) if necessary. 6 8 9 Page no. 1362 JC-DR-A-265.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A265 - Tilt Motor and Drive Assembly 6-2 Reassembly of the Tilt Motor Drive Assembly Reverse the disassembly procedure. 7 COMPLETION Carry out the following calibrations: Calibrations - Checks Job Card Acquisition Image Chain Tube Tilt Calibration Job Card CAL A027 - Tube Tilt Calibration on page 1681 Collimator Calibration Job Card CAL A029 - Collimator Format Calibration on page 1683 Collimation Check Job Card ELE A028 - Collimation Checks on page 679 If Collimation Check not OK, repeat Collimator Calibration. Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 If IQ Tests not OK, repeat all calibrations from Bad Pixel. Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Use the same dosimeter as that used for CAL A046 AOP: Automatic Optimization of Parameters AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations from AOP Calibration. Page no. 1363 JC-DR-A-265.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A265 - Tilt Motor and Drive Assembly This page is blank. Chapter 9 Page no. 1364 JC-DR-A-265.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A266 - Tube Tilt Board Job Card D/R A266 - Tube Tilt Board 1 Chapter 9 SUPPLIES Tube Tilt Board 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 2 hours 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 PREREQUISITES • Rotate the arm to 0° and move it to its lowest position for access to the Tilt Board (1). • Switch off the Gantry power. • Remove the tube cover (Refer to Job Card PHY A044 Remove/Reinstall Gantry Covers on page 523). 1 Page no. 1365 JC-DR-A-266.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A266 - Tube Tilt Board 6 PROCEDURE 6-1 Disassembly of the Tilt Stepper Board 1. Unplug all cables from the Tilt Board, after noting their positions. 2 2. Remove the four screws (2) securing the Tilt Board. (2.5 mm allen wrench). 3. Remove the Tilt Board. 6-2 Reassembly of the Tilt Stepper Board Reverse the disassembly procedure. Chapter 9 Page no. 1366 JC-DR-A-266.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A266 - Tube Tilt Board 7 COMPLETION 7-1 Firmware Check Check whether the new Tube Tilt Board firmware needs to be updated, as follows: 1. Reboot the Senographe system. 2. Go to the Service Desktop home page (see Launching the Service Desktop on page 120). 3. Consult Table 1 on page 63 in the section Component FW/SW to ADS Version compatibility Matrix on page 63. Determine the system level from the ADS/IDC/Generator CPU versions displayed on the Service Desktop home page, and by consulting Table 1 on page 63. The system level will be defined by one of the System Level (Model Number) columns in Table 1 on page 63. 4. Check whether the current firmware version(s) for the new Tube Tilt Board corresponds to the required firmware version for the that system level. • If the current firmware version(s) match the required version(s) quoted in Table 1 on page 63, no additional steps are required. • If the current firmware version(s) does not match the required version(s), you must perform a firmware update of the mismatched firmware version(s) so that the new Tube Tilt Board firmware version(s) match those quoted in Table 1 on page 63. To update the new Tube Tilt Board firmware follow the instructions supplied in the Gantry Software Update CD-ROM that is kept with the system. 7-2 Calibrations Carry out the following calibrations: Calibrations - Checks Job Card Acquisition Image Chain Tube Tilt Calibration Job Card CAL A027 - Tube Tilt Calibration on page 1681 Collimator Calibration Job Card CAL A029 - Collimator Format Calibration on page 1683 Collimation Check Job Card ELE A028 - Collimation Checks on page 679 If Collimation Check not OK, repeat Collimator Calibration. Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 If IQ Tests not OK, repeat all calibrations from Bad Pixel. Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Use the same dosimeter as that used for CAL A046 AOP: Automatic Optimization of Parameters AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations from AOP Calibration. Page no. 1367 JC-DR-A-266.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A266 - Tube Tilt Board This page is blank. Chapter 9 Page no. 1368 JC-DR-A-266.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A280 - Collimator Set Job Card D/R A280 - Collimator Set 1 Chapter 9 SUPPLIES SFOV Collimator (without filter wheel) and a Collimator Control Board. ! Notice: The Collimator (without filter wheel) is delivered with a Collimator Control Board, which contains parameter settings specific to the new Collimator. In order for the new Collimator to function correctly, you must also change the Collimator Control Board that is supplied with the Collimator. 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 2 hours 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 • • • PREREQUISITES Rotate the arm to 180° for access to the collimator. Switch off the Gantry power. Remove the tube cover (Refer to Job Card PHY A044 Remove/Reinstall Gantry Covers on page 523) to access the Collimator Control Board (1), the Collimator (2) and the Filter Wheel (3). 2 1 3 Page no. 1369 JC-DR-A-280.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A280 - Collimator Set 6 PROCEDURE 6-1 Disassembly of the Collimator Control Board 4 (four places) 1. Disconnect all three cables: - Collimator cable (connector J8). - Power cable (connector J9). - CAN cable (connector J10). Do not move the cables too much so that it is easier to reconnect them when you install the new Collimator board. 2. Release and remove the four nuts and washers securing the Collimator Control Board (4) (5.5 mm open-ended wrench). 3. Remove the old Collimator Control Board. 6-2 Disassembly of the Collimator 5 6 7 1. Remove the two screws (11, one each side) securing the rear plate (12) which supports the FOV button (4 mm allen wrench). 2. Using an antistatic bag as protection, place the plate and button on the X-ray head support arm. ! Notice: Do not attempt to disconnect the FOV button. Do not allow the plate to hang down; the FOV connection is fragile. 3. Remove the four screws (9, two each side) which secure the X-ray containment box (8) (4 mm allen 8 9 10 11 12 wrench). 4. Remove the X-ray containment box. If necessary, first 13 remove the two screws (10) which secure the fan protection box (3 mm allen wrench). 5. Remove the two screws securing the connector pro14 tection box (7) (small cross-head screwdriver). 15 6. Disconnect four cables. - Lamp cable W503 (flying lead) (13) 16 - Collimator cable W501 (14) - Filter wheel cable W505 (15) - Filter wheel cable W507 or W509 (16) 7. Release and remove the four screws (6, two each side) securing the Collimator (4 mm allen wrench). 8. Remove the Collimator (5). Chapter 9 Page no. 1370 JC-DR-A-280.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A280 - Collimator Set 6-3 Reassembly of the new Collimator Control Board 1. Carefully place the new Collimator Control board that was delivered with the new Collimator in position. Ensure that you do not pinch the power cable when you tighten the four nuts. 1 J10 J8 J9 2. Attach the four nuts (1) and washers to secure the Collimator Control Board (5.5 mm open-ended wrench) to the framework. 3. Connect the cables to the following connectors on the new Collimator Control Board: - Collimator cable (multicolored ribbon cable) to connector J8. Ensure that the collimator cable does not pass over in close proximity to the microprocessor on the Collimator Control Board. - Power cable (multicolored cable) to connector J9. Ensure that the power cable is routed between the side of the framework and the side of the Collimator Control Board. - CAN cable (gray cable with small multicolored cables) to connector J10. The connectors J2, J3, J4, and J5 are empty. 4. Ensure that the three jumpers TP17, TP20, and CC1TP (to the right of the empty J3 connector) are all open. TP20 TP17 CC1TP Page no. 1371 JC-DR-A-280.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A280 - Collimator Set 5. Power on the Gantry and check that no errors are raised on the Gantry LCD display. 6. Check that the LED states are as follows. For more information about the behavior and states of the Collimator Control board LEDs, refer to Collimator Control Board PL403 on page 295. 6-4 LED Label LED Color LED Status DS1 Green ON DS2 Green OFF or ON DS3 Green ON DS4 Green ON DS5 Green ON DS6 Green OFF DS7 Red OFF DS8 Red OFF DS9 Red OFF DS10 Red OFF Reassembly of the Collimator 1 2 7 1. Replace the new Collimator (1). 2. Reattach the four screws (2, two each side) securing the Collimator (4 mm allen wrench). 3. Use a torque wrench to tighten the four screws (2, two each side) to 3.0 Nm ± 0.2 Nm. 4. Apply Blue Loctite 243 around the heads of the four screws (2, two each side). 5. Reconnect four cables. - Lamp cable W503 (flying lead) (3) - Collimator cable W501 (4) - Filter wheel cable W505 (5) 10 9 8 11 12 - Filter wheel cable W507 or W509 (6) 3 6. Reattach the two screws securing the connector protection box (7) (small cross-head screwdriver). 7. Replace the X-ray containment box. If necessary, first 4 reattach the two screws (8) which secure the fan pro5 tection box (3 mm allen wrench). 8. Reattach the four screws (9, two each side) which 6 secure the X-ray containment box (10) (4 mm allen wrench). 9. Reconnect the plate and FOV button. 10. Reattach the two screws (11, one each side) securing the rear plate (12) which supports the FOV button (4 mm allen wrench). 11. Check visually that all screws securing the Collimator are well mounted. Chapter 9 Page no. 1372 JC-DR-A-280.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A280 - Collimator Set 7 COMPLETION Carry out the following calibrations. Calibrations - Checks Job Card Acquisition Image Chain Collimator Calibration Job Card CAL A029 - Collimator Format Calibration on page 1683 Collimation Check Job Card ELE A028 - Collimation Checks on page 679 If Collimation Check not OK, repeat Collimator Calibration. Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 If IQ Tests not OK, repeat all calibrations from Bad Pixel. Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Use the same dosimeter as that used for CAL A046 AOP: Automatic Optimization of Parameters AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations from AOP Calibration. Page no. 1373 JC-DR-A-280.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A280 - Collimator Set This page is blank. Chapter 9 Page no. 1374 JC-DR-A-280.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A285 - Collimator Filter Wheel Assembly Job Card D/R A285 - Collimator Filter Wheel Assembly 1 Chapter 9 SUPPLIES Collimator Filter Wheel Assembly The Filter Wheel Assembly is not compatibile with older Collimators that use Fairchild optical sensors. The Filter Wheel Assembly is only compatibile with Collimators that use Optek optical sensors. Before you change the Filter Wheel Assembly, you must determine if you also need to change the Collimator so that it is compatible with the new Filter Wheel Assembly. Locate the Collimator Box Number given on the label on the side of the Collimator. Use the Collimator Box Number in the table below of the Collimator to identify the type of optical sensors that are used by the current Collimator. Perform the task described in the table below depending on the Collimator Box Number of the existing Collimator. Collimator Box Number Optic Task Type Compatible with Filter Wheel 2386869 Rev 1 Fairchild No Change existing Collimator for a new Collimator (PN 2408847) before you change the Filter Wheel Assembly. 2386869-1 Rev 1 Fairchild No Change existing Collimator for a new Collimator (PN 2408847) before you change the Filter Wheel Assembly. To Order 2386869-1 Rev 2 Optek Yes Keep existing Collimator. Follow this Job Card to change the Filter Wheel Assembly. 2386869-1 Rev 3 Optek Yes Keep existing Collimator. Follow this Job Card to change the Filter Wheel Assembly. 2 Collimator Box FRU 2386869 System uses Faulhaber motors 2386869-1 System uses Maxon motors 2408847 System uses Maxon motors APPLICABILITY This Job Card applies to the core product. If the system has the CESM option, perform the CESM version of this Job Card located in the CESM SIP instead. 3 TOOLS Standard Tool Box 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 2 hours 5 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. Page no. 1375 JC-DR-A-285.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A285 - Collimator Filter Wheel Assembly 6 • • • PREREQUISITES Rotate the arm to 180° for access to the collimator. Switch off the Gantry power. Remove the tube cover (Refer to Job Card PHY A044 Remove/Reinstall Gantry Covers on page 523) to access the Filter Wheel (1). 1 7 PROCEDURE 1. Remove the two screws (2, one each side) securing the rear plate (3) which supports the FOV button (4 mm allen wrench). 2. Using an antistatic bag as protection, place the plate and button on the X-ray head support arm. ! Notice: Do not attempt to disconnect the FOV button. Do not allow the plate to hang down; the FOV connection is fragile. 3. Remove the four screws (9, two each side) which secure the X-ray containment box (4) (4 mm allen wrench). 4. Remove the X-ray containment box. If necessary, first remove the two screws (5) which secure the fan protection box (3 mm allen wrench). 5. Remove the two screws securing the connector protection box (6) (small cross-head screwdriver). 6. Disconnect four cables. - Lamp cable W503 (flying lead) (7) - Collimator cable W501 (8) - Filter wheel cable W505 (9) Chapter 9 12 11 4 6 9 5 2 3 7 8 9 10 Page no. 1376 JC-DR-A-285.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A285 - Collimator Filter Wheel Assembly - Filter wheel cable W507 or W509 (10) 7. Release and remove the four screws (11, two each side) securing the Collimator (4 mm allen wrench). 8. Remove the Collimator (12). 9. Release and remove the two screws (13) securing the Fil13 ter Wheel assembly (2.5 mm allen wrench). 10. Carefully remove the faulty Filter Wheel assembly. 11. Insert a new Filter Wheel assembly. 12. Reattach the two screws (13) to secure the Filter Wheel (2.5 mm allen wrench). 13. Replace the Collimator (14). 14 15 14. Reattach the four screws (15, two each side) securing the Collimator (4 mm allen wrench). 15. Use a torque wrench to tighten the four screws (2, two each side) to 3.0 Nm ± 0.2 Nm. 16. Apply Blue Loctite 243 around the heads of the four screws (2, two each side). 17. Reconnect four cables. - Lamp cable W503 (flying lead) (16) - Collimator cable W501 (17) - Filter wheel cable W505 (18) - Filter wheel cable W507 or W509 (19) 23 18. Reattach the two screws securing the connector protection box (20) (small cross-head screwdriver). 16 19. Replace the X-ray containment box. If necessary, first reattach the two screws (21) which secure the fan protection box (3 mm allen wrench). 17 20. Reattach the four screws (22, two each side) which secure the X-ray containment box (23) (4 mm allen wrench). 21. Reconnect the plate and FOV button. 22. Reattach the two screws (24, one each side) securing the rear plate (25) which supports the FOV button (4 mm allen wrench). 23. Check visually that all screws securing the Collimator are well mounted. Page no. 1377 JC-DR-A-285.fm 20 22 21 24 25 18 19 Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A285 - Collimator Filter Wheel Assembly 8 COMPLETION Carry out the following calibrations. Calibrations - Checks Job Card Acquisition Image Chain Collimator Calibration Job Card CAL A029 - Collimator Format Calibration on page 1683 Collimation Check Job Card ELE A028 - Collimation Checks on page 679 If Collimation Check not OK, repeat Collimator Calibration. Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 If IQ Tests not OK, repeat all calibrations from Bad Pixel. Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Use the same dosimeter as that used for CAL A046 AOP: Automatic Optimization of Parameters AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations from AOP Calibration. Chapter 9 Page no. 1378 JC-DR-A-285.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A287 - Collimator DC-DC Board Job Card D/R A287 - Collimator DC-DC Board 1. Chapter 9 SUPPLIES Collimator DC-DC Board 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 2 hours 4. SAFETY PRECAUTIONS WARNING The Gantry must be powered OFF. 5. • • • PREREQUISITES Rotate the arm to 180° for access to the collimator. Switch OFF the Gantry power. Remove the tube cover (Refer to Job Card PHY A044 Remove/Reinstall Gantry Covers on page 523) to access the Collimator DC-DC Board (1), which is below the Collimator Control Board. 2 1 3 Page no. 1379 JC-DR-A-287.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A287 - Collimator DC-DC Board 6. PROCEDURE 6-1 Disassembly of the Collimator Control Board 1. Disconnect all three cables: - Collimator cable (connector J8). - Power cable (connector J9). - CAN cable (connector J10). Do not move the cables too much so that it is easier to reconnect them when you reinstall the Collimator Control Board. 1 J10 J8 J9 2. Release and remove the four nuts and washers securing the Collimator Control Board (4) (5.5 mm open-ended wrench). 3. Remove the Collimator Control Board to expose the Collimator DC-DC board. 6-2. Change the Collimator DC-DC Board 1. 2. 3. 4. Unplug all connectors from the Collimator DC-DC Board. Remove the four nuts securing the Collimator DC-DC Board (5.5 mm Open-ended wrench). Remove the faulty Collimator DC-DC Board. Carefully put the new Collimator DC-DC Board in place, and secure it to the framework with the four nuts (5.5 mm Open-ended wrench). 5. Reconnect cables to the Collimator DC-DC Board. Chapter 9 Page no. 1380 JC-DR-A-287.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A287 - Collimator DC-DC Board 6-3 Reassembly of the Collimator Control Board 1. Carefully place the original Collimator Control board in position. Ensure that you do not pinch the power cable when you tighten the four nuts. 1 J10 J8 J9 2. Attach the four nuts (1) and washers to secure the Collimator Control Board (5.5 mm open-ended wrench) to the framework. 3. Connect the cables to the following connectors on the new Collimator Control Board: - Collimator cable (multicolored ribbon cable) to connector J8. Ensure that the collimator cable does not pass over in close proximity to the microprocessor on the Collimator Control Board. - Power cable (multicolored cable) to connector J9. Ensure that the power cable is routed between the side of the framework and the side of the Collimator Control Board. - CAN cable (gray cable with small multicolored cables) to connector J10. The connectors J2, J3, J4, and J5 are empty. 4. Ensure that the three jumpers TP17, TP20, and CC1TP (to the right of the empty J3 connector) are all open. Page no. 1381 JC-DR-A-287.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A287 - Collimator DC-DC Board TP20 TP17 CC1TP 5. Power on the Gantry and check that no errors are raised on the Gantry LCD display. 6. Check that the LED states are as follows. For more information about the behavior and states of the Collimator Control board LEDs, refer to Collimator Control Board PL403 on page 295. LED Label LED Color LED Status DS1 Green ON DS2 Green OFF or ON DS3 Green ON DS4 Green ON DS5 Green ON DS6 Green OFF DS7 Red OFF DS8 Red OFF DS9 Red OFF DS10 Red OFF 7. Reboot the Senographe system and verify that the Collimator blades move as expected. 7 COMPLETION None. Chapter 9 Page no. 1382 JC-DR-A-287.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A288 - Collimator Lamp Job Card D/R A288 - Collimator Lamp 1 Chapter 9 SUPPLIES Collimator Light Assembly. New centering device lamp (only genuine part number 2377836 must be used, to ensure correct light intensity, easy filament centering and reliability). 2 TOOLS Standard Tool Box including a small Pozi screwdriver 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 2 hours 4 SAFETY PRECAUTIONS Not applicable. 5 PREREQUISITES • Rotate the arm to 0° and move it to its comfortable working position to access to the Collimator Lamp (1). • Switch off the Gantry power. • Remove the tube cover (refer to Job Card PHY A044 Remove/Reinstall Gantry Covers on page 523) to access the Collimator (1). Page no. 1383 JC-DR-A-288.fm 1 Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A288 - Collimator Lamp 6 PROCEDURE Note: It is not necessary to remove the Collimator when changing the Collimator Lamp. 6-1 Remove the Old Lamp CAUTION Wait for the lamp to cool before removing it. 1. Remove the two screws (5, one each side) securing the rear plate (6) which supports the FOV button (4 mm allen wrench). 4 3 2 5 6 2. Using an antistatic bag as protection, place the plate and FOV button on the X-ray head support arm. ! Notice: Do not attempt to disconnect the FOV button. Do not allow the plate to hang down; the FOV connection is fragile. 3. Remove the four screws (3, two each side) which secure the X-ray containment box (2). 4. Remove the X-ray containment box. If necessary, first remove the two screws (4) which secure the fan protection box. 5. Remove the four screws (7) securing the right collimator cover (small Pozi screwdriver). 7 Chapter 9 Page no. 1384 JC-DR-A-288.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A288 - Collimator Lamp 6. Disconnect the lamp connector (8). 10 8 9 7. Release the two screws (9) securing the lamp (10) and its support (2.5 mm allen wrench). Be careful not to damage or move the mirror when you release the screws. 8. Remove the lamp. Page no. 1385 JC-DR-A-288.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A288 - Collimator Lamp 6-2 Install the New Lamp CAUTION When handling the new lamp, do not to touch its surface with your fingers. Always use a clean dry cloth or paper handkerchief. 1. Slide the new lamp (1) into position until it reaches the end of the slot. 1 3 2 Position = 11.5 mm 2. Partially secure the lamp with washers and allen screws (2) inside the collimator (2.5 mm allen wrench), so that its position can be adjusted. 3. Adjust the position of the lamp to so that the end of its support is 11.5 mm from the side of the Collimator. 4. Fully secure the lamp, tightening the allen screws (2) to a torque of 1.1 Nm. 5. Connect the lamp to the cable (3). 6. Reinstall the right collimator cover with the small screws (4) (small Pozi screwdirver). 4 Chapter 9 Page no. 1386 JC-DR-A-288.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A288 - Collimator Lamp 7. Reinstall the X-ray containment box. If necessary, first put back the two screws (5) to secure the fan protection box. 5 7 6 9 8 8. Reinstall the X-ray containment box (6) with the four screws (7, two each side) . 9. Reinstall the plate and FOV button (8) on the X-ray head support arm with the two screws (9, one each side) (4 mm allen wrench). 10. Check visually that all screws securing the Collimator are well mounted. 11. Perform Job Card ELE A028 - Collimation Checks on page 679 to determine whether the congruence of the light field with the X-ray field is such that the total misalignment (sum of misalignments on opposite sides) is within the limits set by your local regulations. • If this congruence action limit is met, go to Completion on page 1390. • If this congruence action limit is not met, go to Adjusting a Newly Installed Lamp on page 1388. Page no. 1387 JC-DR-A-288.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A288 - Collimator Lamp 6-3 Adjusting a Newly Installed Lamp If the newly installed lamp failed the congruence action limit, perform the following steps: 1. Remove the two screws (5, one each side) securing the rear plate (1) which supports the FOV button (4 mm allen wrench). 4 3 2 5 1 2. Using an antistatic bag as protection, place the plate and button on the X-ray head support arm. ! Notice: Do not attempt to disconnect the FOV button. Do not allow the plate to hang down; the FOV connection is fragile. 3. Remove the four screws (3, two each side) which secure the X-ray containment box (2). 4. Remove the X-ray containment box. If necessary, first remove the two screws (4) which secure the fan protection box. 5. Remove the four screws (6) securing the right collimator cover (small Pozi screwdriver). 6 6. Slightly untighten the screws (7) securing new lamp (8) and reposition the lamp until you are satisfied with its new position. Use the results from Job Card ELE A028 - Collimation Checks on page 679 Chapter 9 Page no. 1388 JC-DR-A-288.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A288 - Collimator Lamp help you determine in which direction to reposition the lamp. 8 3 7 Reposition accordingly 7. Fully secure the lamp, tightening the allen screws (7) to a torque of 1.1 Nm. 8. Reinstall the right collimator cover with the small screws (8) (small Pozi screwdirver). 8 Page no. 1389 JC-DR-A-288.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A288 - Collimator Lamp 9. Reinstall the X-ray containment box. If necessary, first put back the two screws (9) to secure the fan protection box. 9 11 10 13 12 10. Reinstall the X-ray containment box (10) with the four screws (11, two each side) . 11. Reinstall the plate and FOV button (12) on the X-ray head support arm with the two screws (13, one each side) (4 mm allen wrench). 12. Check visually that all screws securing the Collimator are well mounted. 13. Perform Job Card ELE A028 - Collimation Checks on page 679 to determine whether the congruence of the light field with the X-ray field is such that the total misalignment (sum of misalignments on opposite sides) is within the limits set by your local regulations. • If this congruence action limit is met, go to Completion on page 1390. • If this congruence action limit is not met, go to Adjusting a Newly Installed Lamp on page 1388. 7 COMPLETION If the Collimator and or Interface Plate moved during replacing the Collimator Lamp, then perform a complete set of calibrations according to Completion on page 1373 in Job Card D/R A280 - Collimator Set. Chapter 9 Page no. 1390 JC-DR-A-288.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A290 - FOV Button Job Card D/R A290 - FOV Button 1 Chapter 9 SUPPLIES FOV button 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 15 minutes 4 SAFETY PRECAUTIONS WARNING The Gantry must be powered off. 5 PREREQUISITES None 6 PROCEDURE 6-1 Disassembly of the FOV Buttons 1. Switch off the Senographe electrical power. 2. Remove the tube head covers; refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. 3. Disconnect the W510 cable from the J4 connector on the Tube Tilt board. 4. Remove the allen screws (1) on each side of the Tube Head (3 mm allen wrench). 1 1 Page no. 1391 JC-DR-A-290.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A290 - FOV Button 5. Pull the FOV button away from the Tub Head to remove them from the Tube Head. 6. Follow the FOV button W510 cables (2) up to the top of the Tube Head, cutting the cable ties (3) that secure the cables to the framework. 2 3 7. Fully remove the FOV button. 6-2 Reassembly of the FOV Buttons 1. Route the W510 cables of the new FOV button (1) up to the top of the Tube Head and to the Tilt Board. 1 2 2. Connect the W510 cable to the J4 connector on the Tube Tilt board. 3. Use the cable ties (2) that secure the cables to the framework. 4. Put the new FOV button in place on the back of the Tube Head. Secure the new FOV button on each Chapter 9 Page no. 1392 JC-DR-A-290.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A290 - FOV Button side of the Tube Head with allen screws (3)(3 mm allen wrench). 3 3 5. Replace the tube head covers; refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. 7 COMPLETION After changing the FOV button, no calibrations are necessary. Page no. 1393 JC-DR-A-290.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A290 - FOV Button This page is blank. Chapter 9 Page no. 1394 JC-DR-A-290.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A291 - Stop Button Job Card D/R A291 - Stop Button 1 Chapter 9 SUPPLIES Stop Button 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS WARNING Before beginning work, shut down the equipment and switch off the Generator hospital supply circuit breaker. Lock it in the off position or mark it clearly with a warning sign to prevent others from applying power. Never lay a cover down with the painted side on a hard surface. 5 PREREQUISITES None 6 PROCEDURE 1. Switch off the Senographe electrical power. 2. Remove the top column cover where the broken stop button is located (either left-hand side or righthand side). Refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. 3. Search for and remove the fallen retaining ring from inside the column (if found). 4. Assemble the new Stop button on to the cover. To do this, put the spring (1) under and against the button (2) (see illustration 1). 3 1 2 Clip the retaining ring into the recess of the Stop button. Ensure that the open side of the retaining ring is oriented towards the longitudinal cutout of the Stop button. Illustration 1 Illustration 2 5. Ensure that the Stop button is correctly orientated so that corner of the triangle logo is pointing down (see Illustration 3). Then push the Stop button through the cover (see Illustration 2) so that the recess at the end of the Stop button is fully accessible. Page no. 1395 JC-DR-A-291.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A291 - Stop Button 6. Clip the fixation ring (3) onto the recess in the back of the Stop button (see Illustration 2). Ensure that the fixation ring is oriented so that the open side of the ring is towards the longitudinal cut-out of the Stop button. . NOTE: One corner of the triangle logo must point downwards. Illustration 3 7. Manually press the Stop button from outside the covers and release it. Visually observe that the Stop button presses in and returns without any jams. Repeat this test five times. 8. Re-assemble the top cover back to the column; refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523. 7 COMPLETION After changing the Stop button, no calibrations are necessary. Chapter 9 Page no. 1396 JC-DR-A-291.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A292 - Tube Tilt Pivots Job Card D/R A292 - Tube Tilt Pivots 1 SUPPLIES Part Number 5412241 Description Tube Tilt pivot Kit which includes: • • 2 Chapter 9 FRU FRU orderable 2291796 right tube tilt pivot (1x) and 2291797 left tube tilt pivot (1x) 99059758 M 5X10 screws (2x) and 2192408 M 3X8/8 A4-70 screws (3x) TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 3 to 4 hours including all calibrations and functional checks 4 SAFETY PRECAUTIONS WARNING Be careful when touching the tube housing as its temperature can be up to 80°C (about 180°F). 5 • • PREREQUISITES Rotate the arm to 90° counterclockwise, placing the tube head at the 9-o’clock position. Switch off the Gantry power. WARNING • The Senographe system must be powered OFF and LOTO applied. Switch OFF the electrical power supply from the Mains Distribution Panel in the room. Apply an appropriate LOTO padlock and label. Remove the tube cover (see Job Card Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). Page no. 1397 JC-DR-A-292.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A292 - Tube Tilt Pivots 6 PROCEDURE CAUTION Before proceeding, make sure that the arm is horizontal, with the tube head rotated left to the 9-o’clock position, so that the tube assembly is supported in order to prevent the tube from falling when the pivots are removed. Replacing the pivots with the tube weight resting on the left-side fixed pivot will also help ensure that there will be no lateral play in the tube assembly when the adjustable right-side pivot is secured. To replace the tube tilt pivot, do the following: 1. Release and remove the three screws securing the left pivot (1) (2 mm allen wrench). 1 2. Release and remove the screw securing the right pivot (2 mm allen wrench). 3. Pull out and remove the pivots. The pivot has a screw hole. So, you can insert a screw to help pull or extract it if necessary. 4. Attach the new left pivot so it is flush against the housing, and tighten the three new screws to secure it. 5. Attach and push down firmly on the new right pivot to ensure a tight fit and no lateral tube play. Tighten the new screw and disregard the other new screw. Chapter 9 Page no. 1398 JC-DR-A-292.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A292 - Tube Tilt Pivots 7 COMPLETION 1. Switch ON the Gantry. 2. Switch ON the electrical power supply from the Mains Distribution Panel in the room. Note: Before performing the calibrations and checks listed below, carry out a detector clear calibration. From the Service Desktop, click the Calibrations button, then select Detector and Clear Calibration. Calibrations / Checks Job Cards Acquisition Image Chain Tube Tilt Calibration Job Card CAL A027 - Tube Tilt Calibration on page 1681 Collimator Calibration Job Card CAL A029 - Collimator Format Calibration on page 1683 Collimation Check Job Card ELE A028 - Collimation Checks on page 679 If Collimation Check not OK, repeat Collimator Calibration Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 Flat field tests Job Card ELE M032 – IQ Tools Flat Field Test on page 813 Mag Resolution Test Job Card ELE M034 - IQ Tools Mag Resolution Test on page 835 If IQ Tests not OK, repeat all calibrations from Bad Pixel Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 IQ Tools Composite test Job Card ELE M033 - IQ Tools Composite Test on page 821 If Composite Test not OK, repeat all calibrations from Half Value Layer AOP: Automatic Optimization of Parameters AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations from AOP Calibration Page no. 1399 JC-DR-A-292.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A292 - Tube Tilt Pivots This page is blank. Chapter 9 Page no. 1400 JC-DR-A-292.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A311 - AWS Unit Job Card D/R A311 - AWS Unit 1 • Chapter 9 SUPPLIES AWS unit (SB 150 for V1/V2 Control Stations, U20 for V3 Control Stations and Z400 for V4 Control Stations) CD-ROM Senographe DS AWS Application Software (supplied with the system). Embedded Publications CD-ROM(s) (supplied with the system) • • 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 90 minutes 4 SAFETY PRECAUTIONS WARNING Before beginning work, shut down correctly the equipment and switch off the Senographe system hospital supply circuit breaker. Lock it in the off position or mark it clearly with a warning sign to prevent others from applying power. Never switch off at the UPS except in an emergency (risk of data loss). 5 • • PREREQUISITES If possible, backup the existing data on the current AWS unit. See Job Card ELE A052 - Back-up/ Restore Procedure on page 771. Make a backup of the Repeat and Reject Analysis database. Use the AWS Export Database feature as described in the chapter QC Tests for the Radiologic Technologist of the Senographe DS QC Manual. ! Notice: If there is a system failure that results in the loss of information from the Repeat and Reject Analysis database, an entry must be recorded in the QC log. This QC log entry must describe the occurrence and the cause of data loss, to provide documentation on the reasons for which an analysis may not be available in a particular period. A Field Service record must also be prepared to indicate the nature of the failure and loss of information. • Switch off the Generator hospital supply circuit breaker. 6 PROCEDURE 6-1 Disassembly of Top and Front Covers 1. Remove the X-ray Console. 2. Remove the Control Station top cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 3. Remove the Control Station omega cover. See Job Card PHY A040 - Remove/Reinstall Control StaPage no. 1401 JC-DR-A-311.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A311 - AWS Unit tion Covers on page 503. 6-2 Disassembly/Reassembly of AWS Unit on V1/V2 Control Stations 6-2-1 Disassembly of AWS Unit 1. Locate the AWS unit (1) inside the Control Station. 2 1 V1 Control Station V2 Control Station 2. Remove all the connected cables from the AWS unit rear panel. Note: Note locations of all disconnected cables. 3. Remove the ground cable (screwdriver). 4. Release the AWS unit as follows: • On V1 Control Stations, remove the three nuts securing the upper right corner plate (2) (10 mm open-ended wrench). • On V2 Control Stations, loosen the allen screws which secure the front and back brackets (2) (6 mm allen wrench). For the front bracket, move the modem power supply to access the allen screw. 5. Undo the Velcro strips (3) securing the AWS unit to the Control Station. 3 Chapter 9 Page no. 1402 JC-DR-A-311.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A311 - AWS Unit 6. Remove the defective AWS unit from the Control Station. 6-2-2 If present, remove external CD writer If you are replacing an AWS unit that uses an external CD writer, remove it as follows: 1. Disonnect the SCSI cable from the external CD writer and remove. 2. Disconnect the CD writer’s power cable from the external CD writer and from the UPS. 3. Remove the external CD writer. 6-2-3 Reassembly of the New AWS Unit 1. Place the new AWS unit (1) inside the Control Station. 2 1 V1 Control Station V2 Control Station 2. Secure the AWS unit to the Control Station using the Velcro strips (3). 3 3. Secure the new AWS unit as follows: • On V1 Control Stations, secure the upper right corner plate (2) using three nuts (10 mm openended wrench). • On V2 Control Stations, attach the brackets (2) to the front and back of the ADS unit and tighten the allen screws to secure the front and back brackets (6 mm allen wrench). For the front Page no. 1403 JC-DR-A-311.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A311 - AWS Unit bracket, move the modem power supply to access the allen screw. 4. Reconnect the ground cable (screwdriver). 5. Reconnect all the cables to the AWS unit rear panel. Refer to ADS Rear Panel Connectors (Sun SB150 Workstation) on page 1414 for a guide to cable connections. 6-3 Disassembly/Reassembly of AWS Unit on V3 Control Stations 6-3-1 Disassembly of AWS Unit 1. Locate the AWS unit (1) inside the Control Station. 1 2. Remove all the connected cables from the AWS unit rear panel. Note: Note locations of all disconnected cables. 3. Remove the ground cable (screwdriver). 4. Remove the two allen screws and associated bracket (2) securing the front of the AWS unit (4 mm Chapter 9 Page no. 1404 JC-DR-A-311.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A311 - AWS Unit allen wrench). 2 5. Remove the two allen screws and associated bracket (3) securing the back of the AWS unit (4 mm allen wrench). 3 6. For each of the side L-brackets (4) that secure the AWS unit, do the following: a. Remove the two nuts (5) that secure the L-bracket to the C-bracket (7 mm open ended wrench). b. Untighten (but do not remove) the two allen screws (6) that secure the L-bracket to the Control Station framework (4 mm allen wrench). c. Slide the L-bracket away from the C-Bracket (7). Page no. 1405 JC-DR-A-311.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A311 - AWS Unit d. Gently remove the C-bracket from the top of the AWS unit. 4 6 5 7 7. Remove the defective AWS unit from the Control Station. Chapter 9 Page no. 1406 JC-DR-A-311.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A311 - AWS Unit 6-3-2 Reassembly of the New AWS Unit 1. Place the new AWS unit (1) inside the Control Station. 1 2. Attach the two allen screws and associated bracket (2) to secure the back of the AWS unit (4 mm allen wrench). 2 Page no. 1407 JC-DR-A-311.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A311 - AWS Unit 3. Attach the two allen screws and associated bracket (3) to secure the front of the AWS unit (4 mm allen wrench). 3 4. Secure the top of the AWS unit to each of the side L-brackets (4) as follows: a. Gently place the C-bracket (5) on the top of the AWS unit, so that its threads line up with the holes on the L-bracket. b. Push the L-bracket away onto threads of the C-Bracket. c. Attach the two nuts (6) to secure the L-bracket to the C-bracket (7 mm open ended wrench). d. Tighten the two allen screws (7) to secure the L-bracket to the Control Station framework (4 mm allen wrench). 4 7 Chapter 9 6 5 Page no. 1408 JC-DR-A-311.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A311 - AWS Unit 5. Reconnect the ground cable (screwdriver). 6. Reconnect all the cables to the AWS unit rear panel. Refer to ADS Rear Panel Connectors (Sun U20 Workstation) on page 1415 for a guide to cable connections. 6-4 Disassembly/Reassembly of AWS Unit on V4 Control Stations 6-4-1 Disassembly of AWS Unit 1. Locate the AWS unit (1) inside the Control Station. 1 2. Remove all the connected cables from the AWS unit rear panel. Note: Note locations of all disconnected cables. 3. Remove the ground cable (screwdriver). 4. Remove the two allen screws and associated bracket (2) securing the front of the AWS unit (4 mm allen wrench). 2 Page no. 1409 JC-DR-A-311.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A311 - AWS Unit 5. Remove the two allen screws and associated bracket (3) securing the back of the AWS unit (4 mm allen wrench). 3 6. For each of the side L-brackets (4) that secure the AWS unit, do the following: a. Remove the two nuts (5) that secure the L-bracket to the C-bracket (7 mm open ended wrench). b. Untighten (but do not remove) the two allen screws (6) that secure the L-bracket to the Control Station framework (4 mm allen wrench). c. Slide the L-bracket away from the C-Bracket (7). d. Gently remove the C-bracket from the top of the AWS unit. 4 6 5 7 7. Remove the defective AWS unit from the Control Station. Chapter 9 Page no. 1410 JC-DR-A-311.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A311 - AWS Unit 6-4-2 Reassembly of the New AWS Unit 1. Place the new AWS unit (1) inside the Control Station. 1 2. Attach the two allen screws and associated bracket (2) to secure the back of the AWS unit (4 mm allen wrench). 2 3. Attach the two allen screws and associated bracket (3) to secure the front of the AWS unit (4 mm allen wrench). 3 Page no. 1411 JC-DR-A-311.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A311 - AWS Unit 4. Secure the top of the AWS unit to each of the side L-brackets (4) as follows: a. Gently place the C-bracket (5) on the top of the AWS unit, so that its threads line up with the holes on the L-bracket. b. Push the L-bracket away onto threads of the C-Bracket. c. Attach the two nuts (6) to secure the L-bracket to the C-bracket (7 mm open ended wrench). d. Tighten the two allen screws (7) to secure the L-bracket to the Control Station framework (4 mm allen wrench). 4 7 6 5 5. Reconnect the ground cable (screwdriver). 6. Reconnect all the cables to the AWS unit rear panel. Refer to ADS Rear Panel Connectors (HP Z400 Workstation) on page 1416 for a guide to cable connections. 6-5 Reassembly of Top and Front Covers 1. Reinstall the Control Station omega cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 2. Reinstall the Control Station top cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 3. Reinstall the X-ray Console. 6-6 Software Installation Install the AWS Application from the AWS Application Software CD-ROM supplied with the system. CAUTION • It is important to load the same software version as that installed in the old AWS. Follow the instructions given in the CD-ROM booklet to install the software. Chapter 9 Page no. 1412 JC-DR-A-311.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A311 - AWS Unit 6-7 Embedded Publications Installation For V3 Control Stations that use AWS V53.10.10 or later, and V4 Control Stations, follow the instructions given in Job Card ELE A044 - Install User Publications on page 755 to installed the Embedded Publications. 6-8 Restore Data 1. Restore AWS parameters from the system backup located on the backup diskette or backup CD-R. See section 8 in Job Card ELE A052 - Back-up/Restore Procedure on page 776. If the backup diskette/CD-R is not available, the patients in the Worklist will be lost, and the procedures given in the Job Card ELE A013 - AWS Configuration on page 573 must be performed. 2. Because the IDC and Senographe parameter backup copies were held in the AWS, a new backup must be performed in order to make IDC and Senographe backup parameters available. Perform a system backup. See Job Card ELE A052 - Back-up/Restore Procedure on page 771. ! Notice: If this is not done, no backup for IDC and Senographe parameters will exist. 6-9 Declaration of Network Devices Open the Remote Hosts Selection window (refer to Job Card ELE A023 - Declare Worklist Hosts on page 671) and check that all network devices are still correctly declared. If not, do the following, as required for each network host and printer: • declare the network hosts (refer to Job Card ELE A022 - Declare Network Hosts on page 663) • declare the printers (refer to Job Card ELE A020 - Declare and Set Printers (Filming Devices) on page 585) 6-10 Update the AOP Configuration for Control Stations Running AWS V43.0 or Later (SB150), V53.0 or later (U20) and V54.10 or later (Z400) For Senographe systems that use AWS V43.0 or later (on the SB150), AWS 53.0 or later (on the U20) or AWS 54.10 or later (on the Z400), if the Senographe system does not use the default AOP Classic (AOP A) tables configuration, restore as necessary the AOP configuration (see Job Card ELE A031 - AOP Configuration on page 693). 6-11 Functional Check of New AWS Unit 1. Power up the Senographe system and check that the message All devices are ready appears on the AWS Screen. 2. If the above message appears, the Senographe system is now operational. If not, check that the various connections are correctly made. 3. Perform an image acquisition, then a network transfer to other devices. 7 COMPLETION If the previous AWS unit used an external CD-R writer, explain to the customer that they must now use the internal CD-R writer that is inside the new AWS unit. Page no. 1413 JC-DR-A-311.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A311 - AWS Unit 8 ADS REAR PANEL CONNECTORS (SUN SB150 WORKSTATION) Reference Function 1 Not used 2 Generator Serial Link 2226625 3 Modem Serial Link 4 Not used 2 5 Internal Ethernet Switch (IDC, AWS, Gantry) 2389288 3 10 6 Not used 7 Not used 4 8 Service-specific cable 11 12 13 9 Generator-UPS-ADS Serial Link 2387162 10 Monitor VGA Cable 2390029 11 Not used 12 Not used 13 External Ethernet Link (to hospital network) 14 Mouse or Trackball USB Link 15 Keyboard USB Link 16 Bar Code Reader USB Link 17 Not used 18 AC input 1 5 9 14 15 6 16 17 7 8 18 Chapter 9 Page no. 1414 JC-DR-A-311.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A311 - AWS Unit 9 ADS REAR PANEL CONNECTORS (SUN U20 WORKSTATION) Reference Function 1 AC input 2 Monitor DVI Cable 5177284-2 3 Mouse or Trackball USB Link 4 Keyboard USB Link 5 External Ethernet Link (to hospital network) 6 Bar Code Reader USB Link 7 Not used 8 Generator Serial Link 2226625 9 Service-specific cable 10 Not used 11 Generator-UPS-ADS Serial Link 2387162 12 Internal Ethernet Switch (IDC, AWS, Gantry) (2389288 on Pre-Penduick systems, 2389288-2 on Penduick and above systems) 1 Ground VGA Socket NOT used 3 4 5 12 6 7 2 8 9 10 11 Note: Ensure that the monitor DVI cable is connected to the left hand side DVI connector on the back of the ADS computer. Page no. 1415 JC-DR-A-311.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A311 - AWS Unit 10 ADS REAR PANEL CONNECTORS (HP Z400 WORKSTATION) Reference Function 1 AC input 2 Monitor DVI Cable 5177284-2 via a DVI-I - display port adaptor cable supplied with the Z400. 3 Mouse or Trackball USB Link 4 Keyboard USB Link 5, 6, 8 Not used 7 Bar Code Reader USB Link 9 Internal Ethernet Switch (IDC, AWS, Gantry) (2389288-2) 10 External Ethernet Link (to hospital network) 11 Not used 12 Generator-UPS-ADS Serial Link 2387162 13 Generator Serial Link 2226625 14 Service-specific cable 1 3 4 7 8 5 Ground 6 9 Note: Ensure that the monitor DVI cable is connected to the left hand side display port (number 1) on the back of the ADS computer. The monitor DVI cable must be connected to the display port via a DVI-I - display port 10 adaptor cable shown below. 2 12 11 14 13 Chapter 9 Page no. 1416 JC-DR-A-311.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A312 - Mouse Job Card D/R A312 - Mouse 1 • Chapter 9 SUPPLIES Keyboard type 6 UNIX and Mouse SUN for V2 Control Stations, Keyboard type 7 UNIX and Mouse SUN for V3 Control Stations, XS Complete Mouse for V4 Control Stations Black cable ties • 2 APPLICABILITY Three types of Rotative Arm Sets exist, as follows: • Ergotron A (introduced with V1 Control Stations) - contains one rotative arm support and two extension (rotative) arms • Ergotron B (introduced with V2 Control Stations and early V3 Control Stations) - contains one rotative arm support and two extension (rotative) arms • Sisfle (introduced with V3/V4 Control Stations) - contains one rotative arm support and one extension (rotative) arm The procedure used in this Job Card vary according to the type of rotative arm you have. Since the mouse is not supported on Ergotron A arms, this Job Card is only applicable to V2/V3/V4 Control Stations. 3 TOOLS Standard Tool Box 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 5 SAFETY PRECAUTIONS WARNING Before beginning work, shut down correctly the equipment and switch off the Senographe system hospital supply circuit breaker. Lock it in the off position or mark it clearly with a warning sign to prevent others from applying power. 6 PREREQUISITES None Page no. 1417 JC-DR-A-312.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A312 - Mouse 7 PROCEDURE FOR ERGOTRON B ARMS 7-1 Disassembly of Mouse on Ergotron B Arms 1. Unplug and remove the X-ray Console. 2. Remove Control Station Top Cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 3. Remove Control Station Omega Cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 4. Carefully extract the harness (1) from the rotative arm. 1 5. Cut the cable ties from the monitor harness to free the mouse cable. 6. Disconnect the mouse cable from the ADS computer. 7. Extract the mouse cable from the opening of the rotative arm support (2) and from the mouse and monitor support. 2 8. Remove the mouse. Chapter 9 Page no. 1418 JC-DR-A-312.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A312 - Mouse 7-2 Reassembly of Mouse on Ergotron B Arms 1. Place the new mouse on the mouse mat. 2. Introduce the mouse cable in the opening (1) of the rotative arm. 1 3. Connect the mouse to the ADS Compouter. 4. Route the mouse cable along the monitor harness. Secure the monitor harness and trackball cable with black cable ties. 5. Reinsert the harness (2) into the rotative arm. 2 6. Reinstall the Omega Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 7. Reinstall the Top Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 8. Reinstall the X-ray Console. Page no. 1419 JC-DR-A-312.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A312 - Mouse 8 PROCEDURE FOR SISFLE ARM 8-1 Disassembly of Mouse on Sisfle Arm 1. Unplug and remove the X-ray Console. 2. Remove the Top Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 3. Remove the Omega Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 4. Carefully pull on the upper silicone mask (1) to remove it from the rotative arm. Store the upper silicone mask in a clean place. 1 5. Carefully pull on the lower silicone mask (2) to remove it from the rotative arm support. Store the lower silicone mask in a clean place. 2 Chapter 9 Page no. 1420 JC-DR-A-312.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A312 - Mouse 6. Disconnect the mouse cable from the ADS computer. 7. Cut the cable ties that secure the monitor cables and mouse cable to the Control Station framework (3) and harness (4). 4 3 8. Carefully pull the harness (5) from the upper and lower parts of the rotative arm. 7 5 9. Extract the mouse cable (6) from the hole in the harness, and from the opening of the monitor sup- Page no. 1421 JC-DR-A-312.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A312 - Mouse port (7). Remove the mouse. 8 Chapter 9 Page no. 1422 JC-DR-A-312.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A312 - Mouse 8-2 Reassembly of New Mouse on Sisfle Arm 1. Place the new mouse at the back of the mouse support (so that there is enough cable for use of the mouse on the entire mouse support). 2. Use pointed nose pliers to create an opening in the harness at 27 cm from the end of the harness. 27 cm 3. Route the mouse cable through the opening in the harness, so that it leaves the other end of the harness. Then route the mouse cable through the rotative arm support entrance into the Control Station. 4. Ensure that the rotative arm (1) and rotative arm support (2) are aligned in the same plane. Carefully put the monitor harness inside the rotative arm and rotative arm support. 2 1 Aligned in the same plane. Page no. 1423 JC-DR-A-312.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A312 - Mouse 5. Insert the upper silicone mask (shorter of the two) (3) into the rotative arm. The rounded edge of the silicone mask must point outwards. 3 6. Insert the lower silicone mask (longer of the two) (4) into the rotative arm. The rounded edge of the silicone mask must point outwards. 4 7. Connect the mouse to the ADS computer. Chapter 9 Page no. 1424 JC-DR-A-312.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A312 - Mouse 8. Ensure that the monitor cables have sufficient slack (5) within the Control Station so that they can move. This ensures that the movement of the monitor cables are not inhibited when the rotative arm is turned. Secure the harness to the monitor cables and mouse cable with a cable tie at 1 cm from the end of the harness (6). Secure the monitor cables and mouse cable to the Control Station framework with a cable tie (7). 6 5 7 9. Turn the rotative arm though all extremes, and check that the monitor harness, monitor cables, and mouse cable are free to move as indicated below. Page no. 1425 JC-DR-A-312.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A312 - Mouse 10. Reinstall the Omega Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 11. Reinstall the Top Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 12. Reinstall the X-ray Console. 9 COMPLETION None Chapter 9 Page no. 1426 JC-DR-A-312.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A313 - Trackball Job Card D/R A313 - Trackball Chapter 9 Three types of Rotative Arm Sets exist, as follows: • Ergotron A (introduced with V1 Control Stations) - contains one rotative arm support and two extension (rotative) arms • Ergotron B (introduced with V2 Control Stations and with early V3 Control Stations) - contains one rotative arm support and two extension (rotative) arms • Sisfle (introduced with V3/V4 Control Stations) - contains one rotative arm support and one extension (rotative) arm The procedure used in this Job Card vary according to the type of rotative arm you have. 1 SUPPLIES ADS Trackball Kit 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 60 minutes 4 SAFETY PRECAUTIONS WARNING Before beginning work, shut down correctly the equipment and switch off the Senographe system hospital supply circuit breaker. Lock it in the off position or mark it clearly with a warning sign to prevent others from applying power. 5 PREREQUISITES Calibrate the new replacement Trackball on a laptop in a quiet area (see Job Card ELE A065 - Trackball Configuration on page 787). Page no. 1427 JC-DR-A-313.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A313 - Trackball 6 PROCEDURE FOR ERGOTRON A ARMS 6-1 Disassembly of Trackball on Ergotron A Arms 1. Locate the Control Station Trackball (1). 2 1 2. Release and remove the trackball securing screw (2) (cross-head screwdriver). 3. Unplug the trackball USB cable from the AWS workstation rear panel. 6-2 Reassembly of New Trackball on Ergotron A Arms Reverse the disassembly procedure. 7 PROCEDURE FOR ERGOTRON B ARMS 7-1 Disassembly of Trackball on Ergotron B Arm 1. Unplug and remove the X-ray Console. 2. Remove Control Station Top Cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 3. Remove Control Station Omega Cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 4. Carefully extract the harness (1) from the rotative arm. 1 5. Cut the cable ties from the monitor harness to free the trackball cable. 6. Disconnect the trackball cable from the USB extension cable. 7. Extract the trackball cable from the opening of the rotative arm support (2) and from the trackball and Chapter 9 Page no. 1428 JC-DR-A-313.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A313 - Trackball monitor support. 2 8. Release and remove the trackball securing screw (3) then the spacer (4), and remove the trackball. 4 3 7-2 Reassembly of New Trackball on Ergotron B Arm 1. Install and secure the trackball with the longest screw (1) (length = 38 mm) and spacer (2) that are supplied with the Trackball Kit. The spacer must be located between the handle and the trackball. 2 1 Page no. 1429 JC-DR-A-313.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A313 - Trackball 2. Introduce the trackball cable in the opening (3) of the rotative arm. 3 3. Use either the existing USB extension cable or the USB extension cable to connect the trackball to the ADS computer. Secure the Trackball and USB extension cable connectors with two cable ties (4). 4 4. Route the trackball cable along the monitor harness. Secure the monitor harness and trackball cable with black cable ties which are supplied with the Trackball Kit. 5. Reinsert the harness (5) into the rotative arm. 5 6. Reinstall the Omega Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 7. Reinstall the Top Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 8. Reinstall the X-ray Console. Chapter 9 Page no. 1430 JC-DR-A-313.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A313 - Trackball 8 PROCEDURE FOR SISFLE ARM 8-1 Disassembly of Trackball on Sisfle Arm 1. Unplug and remove the X-ray Console. 2. Remove the Top Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 3. Remove the Omega Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 4. Carefully pull on the upper silicone mask (1) to remove it from the rotative arm. Store the upper silicone mask in a clean place. 1 5. Carefully pull on the lower silicone mask (2) to remove it from the rotative arm support. Store the lower silicone mask in a clean place. 2 Page no. 1431 JC-DR-A-313.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A313 - Trackball 6. Disconnect the trackball cable from the USB extension cable leading to the ADS computer. 7. Cut the cable ties that secure the monitor cables and trackball cable to the Control Station framework (3) and harness (4). 4 3 8. Carefully pull the harness (5) from the upper and lower parts of the rotative arm. 7 5 9. Extract the trackball cable (6) from the hole in the harness, and from the opening of the monitor sup- Chapter 9 Page no. 1432 JC-DR-A-313.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A313 - Trackball port (7). 8 10. Release and remove the trackball securing screw (8) then the spacer (9), and remove the trackball. 8 9 Page no. 1433 JC-DR-A-313.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A313 - Trackball 8-2 Reassembly of New Trackball on Sisfle Arm 1. Install and secure the trackball with the longest screw (1) (length = 38 mm) and spacer (2) that are supplied with the Trackball Kit. The spacer must be located between the handle and the trackball. 2 1 2. Use pointed nose pliers to create an opening in the harness at 27 cm from the end of the harness. 27 cm 3. Route the trackball cable through the opening in the harness, so that it leaves the other end of the harness. Then route the track cable through the rotative arm support entrance into the Control Station. 4. Ensure that the rotative arm (3) and rotative arm support (4) are aligned in the same plane. Carefully put the monitor harness inside the rotative arm and rotative arm support. 4 3 Aligned in the same plane. Chapter 9 Page no. 1434 JC-DR-A-313.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A313 - Trackball 5. Insert the upper silicone mask (shorter of the two) (5) into the rotative arm. The rounded edge of the silicone mask must point outwards. 5 6. Insert the lower silicone mask (longer of the two) (6) into the rotative arm. The rounded edge of the silicone mask must point outwards. 6 7. Use either the existing USB extension cable or the USB extension cable to connect the trackball to the ADS computer. Secure the Trackball and USB extension cable connectors with two cable ties (7). 7 Page no. 1435 JC-DR-A-313.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A313 - Trackball 8. Ensure that the monitor cables have sufficient slack (8) within the Control Station so that they can move. This ensures that the movement of the monitor cables are not inhibited when the rotative arm is turned. Secure the harness to the monitor cables and trackball cable with a cable tie at 1 cm from the end of the harness (9). Secure the monitor cables and trackball cable to the Control Station framework with a cable tie (10). 9 8 10 9. Turn the rotative arm though all extremes, and check that the monitor harness, monitor cables, and trackball cable are free to move as indicated below. Chapter 9 Page no. 1436 JC-DR-A-313.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A313 - Trackball 10. Reinstall the Omega Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 11. Reinstall the Top Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 12. Reinstall the X-ray Console. 9 COMPLETION None Page no. 1437 JC-DR-A-313.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A313 - Trackball This page is blank. Chapter 9 Page no. 1438 JC-DR-A-313.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A314 - External CD-RW Unit Job Card D/R A314 - External CD-RW Unit 1 Chapter 9 APPLICABILITY This Job Card is not required if the internal CD-R writer is present. Applicability code B. See Compatibility codes on page 68. 2 SUPPLIES CD-RW unit 3 TOOLS Standard Tool Kit 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 5 SAFETY PRECAUTIONS None 6 PREREQUISITES The installed AWS software must be ADS version 29.0 or later. 7 PROCEDURE 7-1 Configure the CD-RW unit Switches on the rear panel of the new CD-RW unit must be correctly set before installation. They are not accessible after the Control Station covers have been installed. • Check that the power switch at the rear of the new CD-RW unit is set to to ON (I). A sticker may have been placed over the switch to prevent it from being set off. • Check that the SCSI ID switch is set to 2. If necessary, change the setting up or down by inserting a small flat screwdriver or similar tool into one of the two slots above and below the switch. Page no. 1439 JC-DR-A-314.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A314 - External CD-RW Unit 7-2 Install and connect the new CD-RW unit 1. Power OFF the system. 2. Remove the Control Station top cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 3. Untighten and remove the two screws and washers (1) (3 mm allen wrench) that secure the old CDRW unit to the Control Station. 1 Note: Older CD-RW units that exist in some systems are not mounted in a housing unit. Whereas newer CD-RW units that exist in systems are mounted in a housing unit. 4. Carefully slide the old CD-RW unit from the Control Station, remove the power and SCSI cable from the back panel of the old CD-RW unit and remove it from the Control Station. Leave the power and SCSI cable in a convenient place so that they can be attached to the new CD-RW unit. 5. For newer CD-RW units that need replacing, untighten the four screws (2) that clamp the old CD-RW unit to the housing unit. Slide out the old CD-RW unit from the housing unit. 4 cm 2 6. Slide the new CD-RW unit into the housing unit. Make sure that the distance between the back of the CD-RW unit and the back of the housing unit is 4 cm. 7. Tighten the four screws (2) so that the new CD-RW unit is securely clamped in the housing unit. Chapter 9 Page no. 1440 JC-DR-A-314.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A314 - External CD-RW Unit 8. Connect the power cable and SCSI cable to the back panel of the new CD-RW unit. The SCSI cable must be connected to the top SCSI connector (3). 3 ! Notice: Be careful not to pinch or damage cables. 9. Carefully slide the housing unit that accommodates the new CD-RW unit back into the Control Station. Fit, but do not tighten, the two screws and washers (4) under the CD-RW unit (3 mm allen wrench). The screws should be placed in the second from from the front of the Control Station frame. Position the CD-RW unit centrally. The right edge of the CD-RW unit should be approximately 12.5 cm from the right lateral bar of the Control Station frame. 4 12.5 cm 10. Temporarily mount the top cover, then center the CD-RW unit’s tray with respect to the cover aperture. It is possible and accepted that the width of the CD-RW unit exceeds the width of the opening in the top cover. However, there should be no gap between the CD-RW and the top cover. 11. Once you have aligned the top cover and the CD-RW unit, remove the top cover and tighen the screws and washers (4) so that housing accommodating the CD-RW unit is secured to the Control Station frame. 12. Replace the Control Station top cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 7-3 Verification of installation 1. Power up the Senographe system and insert a blank CD-ROM in the new CD-RW unit. 2. From the Browser,click the CD-R icon and select Query in the drop-down menu. 3. The blank CD-ROM should be recognised by the Query. If the blank CD-ROM is not recognized, check connections, and restart the AWS. Page no. 1441 JC-DR-A-314.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A314 - External CD-RW Unit This page is blank. Chapter 9 Page no. 1442 JC-DR-A-314.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A315 - International Keyboard Job Card D/R A315 - International Keyboard 1 Chapter 9 APPLICABILITY This Job Card is only applicable to V3 and V4 Control Stations. Perform this Job Card if you want to: • change the US Keyboard that is delivered with the Senographe system to an International Keyboard (i.e. keyboard with a different layout to the US layout) • change an existing keyboard (either US Keyboard or International Keyboard) for a keyboard with the same layout. Note: You must not use a Sun keyboard with a V4 Control Station (Z400), since it can lead to keyboard malfunction. 2 SUPPLIES For V3 Control Stations, one of the following keyboards: Keyboard Layout FRU (GE Part Number) German 5233716-2 Swedish 5233716-3 Norwegian 5233716-4 Spanish 5233716-5 French 5233716-6 Portuguese 5233716-7 Italian 5233716-8 Danish 5233716-9 Dutch 5233716-10 Finnish 5233716-11 US (default) 5233716 For V4 Control Stations, one of the following keyboards: Keyboard Layout FRU (GE Part Number) German 5394524-2 Swedish / Finnish 5394524-3 Norwegian 5394524-4 Spanish 5394524-5 French 5394524-6 Portuguese 5394524-7 Italian 5394524-8 Danish 5394524-9 Dutch 5394524-10 US (default) 5394524 Page no. 1443 JC-DR-A-315.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A315 - International Keyboard 3 TOOLS Standard Tool Box 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 5 SAFETY PRECAUTIONS None 6 PREREQUISITES None Chapter 9 Page no. 1444 JC-DR-A-315.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A315 - International Keyboard 7 PROCEDURE FOR V1/V2 CONTROL STATIONS 7-1 Determine the OpenBoot Version of the SB150 Workstation 1. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 2. Query the OpenBoot version of the SB150 Workstation, by entering: prtconf -V The OpenBoot version of the SB150 Workstation appears. • If the OpenBoot version is lower than 4.10.6, then you cannot change the keyboard with an International Keyboard. • If the OpenBoot version is equal to or greater than 4.10.6, then shutdown the Control Station using the shutdown button the Browser, and proceed to section 7-2 to change the keyboard with an International Keyboard. WARNING Before proceeding to section 7-2, shut down correctly the equipment and switch off the Senographe system hospital supply circuit breaker. Lock it in the off position or mark it clearly with a warning sign to prevent others from applying power. 7-2 Connect the new keyboard 1. Unplug and remove the X-ray Console. 2. Remove Control Station Top Cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 3. Remove Control Station Omega Cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 4. Disconnect the original keyboard from the back of the ADS Computer, and remove it from the Control Station. 1 2 3 4 Reference Function 1 Mouse or Trackball USB Link 2 Keyboard USB Link 3 Not used 4 Bar Code Reader USB Link Page no. 1445 JC-DR-A-315.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A315 - International Keyboard 5. Put the new keyboard on the Control Station and connect it to the USB connector at back of the ADS Computer (as illustrated above). 6. Reinstall the Omega Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 7. Reinstall the Top Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 8. Reinstall the X-ray Console. 8 PROCEDURE FOR V3 CONTROL STATIONS The procedure you follow depends on whether you are changing a keyboard with a different layout: • If you are changing the keyboard with a different layout (e.g. from US Keyboard layout to International Keyboard layout) proceed to section 8-1 before changing the keyboard in section 8-2. • If you are changing the keyboard with the same layout (e.g. from US Keyboard layout to US Keyboard layout, or International Keyboard layout to International Keyboard layout), proceed to directly to section 8-2. 8-1 Configure the ADS Workstation for the new Keyboard If you are going to connect a keyboard with a different layout to the ADS Workstation, you must reconfigure the ADS Workstation with the Desktop Manager Configuration Tool before you connect the new keyboard. To do this (with the original keyboard connected), proceed as follows: 1. Reboot the ADS Workstation to ensure that you are at the first Login: prompt. A series of system initialization messages appears on the screen, then the Login: prompt appears. 2. Login as the root user as follows: a. At the Login: prompt, enter: root b. At the Password: prompt, enter: operator A command prompt appears for the root user. 3. At command prompt, launch the Desktop Manager Configuration Tool, by entering: kdmconfig The Desktop Manager Configuration Tool appears. Within the Desktop Manager Configuration Tool you use the cursor keys to move up and down between the different options, and the space bar to select an option. The currently selected option contains an x within the brackets. 4. At the first kdmconfig page, leave the Xsun server option selected. Press the F2 key to continue. 5. At the kdmconfig - View and Edit Window System Configuration page that appears, use the cursor Chapter 9 Page no. 1446 JC-DR-A-315.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A315 - International Keyboard keys to move to the Change Keyboard option, and press the space bar to select that option. Press the F2 key to continue. 6. At the Keyboard Type Selection page that appears, use the cursor keys to move to the keyboard option corresponding to the International Keyboard you are going to install, and press the space bar to select that option. Press the F2 key to continue. You are returned back to the kdmconfig - View and Edit Window System Configuration page. The entry for the Keyboard Type is updated corresponding the choice of keyboard you selected. Page no. 1447 JC-DR-A-315.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A315 - International Keyboard 7. Back at the kdmconfig - View and Edit Window System Configuration page, use the cursor keys to move to the No changes needed - Test/Save and Exit option, and press the space bar to select that option. Press the F2 key to continue. 8. A kdmconfig -Window System Configuration Test page appears, prompting you to test and save the configuration. Press the F4 key to bypass the test, save the configuration and exit the Desktop Manager Configuration Tool. Chapter 9 Page no. 1448 JC-DR-A-315.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A315 - International Keyboard 9. You are returned to the command prompt. Launch the Desktop Manager Configuration Tool again to ensure that the Monitor settings are correct, by entering: kdmconfig The Desktop Manager Configuration Tool appears. Within the Desktop Manager Configuration Tool you use the cursor keys to move up and down between the different options, and the space bar to select an option. The currently selected option contains an x within the brackets. 10. At the first kdmconfig page, leave the Xsun server option selected. Press the F2 key to continue. 11. At the kdmconfig - View and Edit Window System Configuration page that appears, use the cursor keys to move to the Change Video Device/Monitor option, and press the space bar to select that option. Press the F2 key to continue. 12. At the kdmconfig - Video Device Selection page that appears, use the cursor keys to move to the XF86-NV Nvidia Corporation Quadro FX560 option, and press the space bar to select that option. Press the F2 key to continue. 13. At the kdmconfig - Monitor Type Selection page that appears, use the cursor keys to move to the MultiFrequency 64KHz (up to 1600x1200 interlacead) option, and press the space bar to select that option. Press the F2 key to continue. 14. At the kdmconfig - Screen Size Selection page that appears, use the cursor keys to move to the appropriate screen size option (18-inch (46cm) if the system uses an 18" monitor, or 19-inch (48cm) if the system uses a 19" monitor), and press the space bar to select that option. Press the F2 key to continue. 15. At the kdmconfig - Resolution/Colors Selection page that appears, use the cursor keys to move to the 1280x1024 256 colors @ 60Hz option, and press the space bar to select that option. Press the F2 key to continue. 16. At the kdmconfig - View and Edit Window System Configuration page that appears, leave the No changes needed - Test/Save and Exit option selected. Press the F2 key to continue. 17. At the kdmconfig - Window System Configuration Test page that appears, press the F2 key to run the screen test. 18. From the test screen that appears, click on: • Yes, if screen is displayed correctly (buttons and text are readable). • No, if screen is not displayed correctly and redo steps 11 to 17. Once the monitor test is successful, and you click Yes you are automatically returned to the command line. 19. At command prompt, ensure that the Control Station is in safe state for powering down, by entering: shutdown -y -i 0 20. Power down the entire system, and proceed to section 8-2. WARNING Before proceeding to section 8-2, shut down correctly the equipment and switch off the Senographe system hospital supply circuit breaker. Lock it in the off position or mark it clearly with a warning sign to prevent others from applying power. Page no. 1449 JC-DR-A-315.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A315 - International Keyboard 8-2 Connect the new keyboard 1. Unplug and remove the X-ray Console. 2. Remove Control Station Top Cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 3. Remove Control Station Omega Cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 4. Disconnect the original keyboard from the back of the ADS Computer, and remove it from the Control Station. 1 2 3 4 Reference Function 1 Mouse or Trackball USB Link 2 Keyboard USB Link 3 Bar Code Reader USB Link 4 Not used 5. Put the new keyboard on the Control Station and connect it to the USB connector at back of the ADS Computer (as illustrated above). 6. Reinstall the Omega Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 7. Reinstall the Top Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 8. Reinstall the X-ray Console. Chapter 9 Page no. 1450 JC-DR-A-315.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A315 - International Keyboard 9 PROCEDURE FOR V4 CONTROL STATIONS The procedure you follow depends on whether you are changing a keyboard with a different layout: • If you are changing the keyboard with a different layout (e.g. from US Keyboard layout to International Keyboard layout) proceed to section 9-1 before changing the keyboard in section 9-2. • If you are changing the keyboard with the same layout (e.g. from US Keyboard layout to US Keyboard layout, or International Keyboard layout to International Keyboard layout), proceed to directly to section 9-2. 9-1 Configure the ADS Workstation for the new Keyboard If you are going to connect a keyboard with a different layout to the ADS Workstation, you must reconfigure the ADS Workstation with the Desktop Manager Configuration Tool before you connect the new keyboard. To do this (with the original keyboard connected), proceed as follows: 1. Reboot the ADS Workstation to ensure that you are at the first Login: prompt. A series of system initialization messages appears on the screen, then the Login: prompt appears. 2. Login as the root user as follows: a. At the Login: prompt, enter: root b. At the Password: prompt, enter: operator A command prompt appears for the root user. 3. At command prompt, launch the Desktop Manager Configuration Tool, by entering: kdmconfig The Desktop Manager Configuration Tool appears. Within the Desktop Manager Configuration Tool you use the cursor keys to move up and down between the different options, and the space bar to select an option. The currently selected option contains an x within the brackets. 4. At the first kdmconfig page, use the cursor keys to move to the Xsun server option, and press the space bar to select that option. Press the F2 key to continue. 5. At the kdmconfig - View and Edit Window System Configuration page that appears, use the cursor Page no. 1451 JC-DR-A-315.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A315 - International Keyboard keys to move to the Change Keyboard option, and press the space bar to select that option. Press the F2 key to continue. 6. At the Keyboard Type Selection page that appears, use the cursor keys to move to the keyboard option corresponding to the International Keyboard you are going to install, and press the space bar to select that option. Press the F2 key to continue. You are returned back to the kdmconfig - View and Edit Window System Configuration page. The entry for the Keyboard Type is updated corresponding the choice of keyboard you selected. Chapter 9 Page no. 1452 JC-DR-A-315.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A315 - International Keyboard 7. Back at the kdmconfig - View and Edit Window System Configuration page, use the cursor keys to move to the No changes needed - Test/Save and Exit option, and press the space bar to select that option. Press the F2 key to continue. 8. A kdmconfig -Window System Configuration Test page appears, prompting you to test and save the configuration. Press the F4 key to bypass the test, save the configuration and exit the Desktop Manager Configuration Tool. Page no. 1453 JC-DR-A-315.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A315 - International Keyboard 9. You are returned to the command prompt. 10. At command prompt, launch the Desktop Manager Configuration Tool again, by entering: kdmconfig The Desktop Manager Configuration Tool appears. Within the Desktop Manager Configuration Tool you use the cursor keys to move up and down between the different options, and the space bar to select an option. The currently selected option contains an x within the brackets. 11. At the first kdmconfig page, use the cursor keys to move to the Xorg server option, and press the space bar to select that option. Press the F2 key to continue. 12. At the first Xorg Server Configuration Instruction page that appears, press the F2 key to continue. 13. You are returned to the command prompt. 14. At command prompt, ensure that the Control Station is in safe state for powering down, by entering: shutdown -y -i 0 15. Power down the entire system, and proceed to section 9-1. WARNING Before proceeding to section 9-2, shut down correctly the equipment and switch off the Senographe system hospital supply circuit breaker. Lock it in the off position or mark it clearly with a warning sign to prevent others from applying power. Chapter 9 Page no. 1454 JC-DR-A-315.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A315 - International Keyboard 9-2 Connect the new keyboard 1. Unplug and remove the X-ray Console. 2. Remove Control Station Top Cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 3. Remove Control Station Omega Cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 4. Disconnect the original keyboard from the back of the ADS Computer, and remove it from the Control Station. 1 2 5 6 3 4 9 Reference Function 1 Mouse or Trackball USB Link 2 Keyboard USB Link 5 Bar Code Reader USB Link 3, 4, 6 Not used 5. Put the new keyboard on the Control Station and connect it to the USB connector at back of the ADS Computer (as illustrated above). 6. Reinstall the Omega Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 7. Reinstall the Top Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 8. Reinstall the X-ray Console. Page no. 1455 JC-DR-A-315.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A315 - International Keyboard 10 COMPLETION Ensure that the newly installed keyboard is correctly configured, as follows: 1. Power on the Senographe system, and login as the sdc user. 2. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 3. Launch the textedit application, by entering: textedit 4. Within the TextEdit application window that appears, type some characters that are specific to the keyboard that you have installed. Ensure that the characters that are displayed are the same as the keys that you are pressing on the newly installed keyboard. • If the characters displayed correspond to the keys you are pressing, the keyboard is configured correctly. • If the characters displayed do not correspond to the keys you are pressing, the keyboard is not configured correctly, and you must re-perform section 8-1 and select the correct keyboard type using the Desktop Manager Configuration Tool. 5. Double click the Chapter 9 button in the top left of the TextEdit window to exit the textedit application. Page no. 1456 JC-DR-A-315.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A316 - SB-150 CD-ROM Drive Job Card D/R A316 - SB-150 CD-ROM Drive 1 Chapter 9 APPLICABILITY This Job Card is only applicable to V1 and V2 Control Stations. 2 SUPPLIES SB-150 CD-ROM drive 3 TOOLS Standard Tool Box 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 60 minutes 5 SAFETY PRECAUTIONS None 6 PREREQUISITES If possible, ensure that no CD-ROM is already present in the old CD-ROM drive. If you are unable to open the CD-ROM tray with the eject button, you can manually open the CD-ROM tray via the hole on the right hand side of the CD-ROM drive. Manual Eject Hole Page no. 1457 JC-DR-A-316.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A316 - SB-150 CD-ROM Drive 7 PROCEDURE 1. Power off the system, and apply LOTO. 2. Unplug and remove the X-ray Console. 3. Remove Control Station Top Cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 4. Remove Control Station Omega Cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 5. Remove the AWS Computer (SB-150) from the Control Station (refer to Section 6-1, page 1401 in Job Card D/R A311 - AWS Unit). 6. Remove the two screws (cross-head screwdriver) securing the SB-150 cover to the chassis. 7. Slide the SB-150 cover towards the rear of the SB-150 until the cover tabs release. 8. Lift the SB-150 cover straight up and put the cover aside in a safe place. 9. Take the following necessary ESD precautions: a. Unwrap the first two folds of the wrist strap; wrap the adhesive side firmly against your wrist. b. Peel the liner from the copper foil at the opposite end of the wrist strap. c. Attach the copper end of the wrist strap to the chassis. Chapter 9 Page no. 1458 JC-DR-A-316.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A316 - SB-150 CD-ROM Drive ! Notice: Use proper ESD grounding techniques when handling components. Wear an antistatic wrist strap and use an antistatic mat. Store ESD-sensitive components in antistatic bags before placing them on any surface. 10. Remove the IDE cable (1) and power cable (2) from the back of the CD-ROM drive. 1 2 11. Remove the two screws (cross-head screwdriver) securing the CD-ROM drive to the chassis. 12. Place your fingers on the back of the CD-ROM drive. Push the CD-ROM DVD-ROM drive toward the chassis front and remove it. 13. Place the faulty CD-ROM in an antistatic bag. 14. Take the new CD-ROM drive, and verify that the drive back panel mode-select jumper is set to Page no. 1459 JC-DR-A-316.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A316 - SB-150 CD-ROM Drive "Cable Select (CS). Jumper information listed here Cable Select (CS) 15. Position the new CD-ROM drive in the chassis. 16. Push the CD-ROM drive toward the chassis rear. 17. Replace the two screws (cross-head screwdriver) to secure the CD-ROM drive to the chassis. 18. Connect the IDE cable (3) and power cable (4) to the back of the CD-ROM drive. Ensure that the cable assembly connectors are properly oriented by aligning the connector keys. 3 Chapter 9 4 Page no. 1460 JC-DR-A-316.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A316 - SB-150 CD-ROM Drive 19. Detach the wrist strap. 20. Replace the SB-150 cover, and use the two screws (cross-head screwdriver) to secure the SB-150 cover to the chassis. 21. Put the SB-150 Workstation back into the Control Station (refer to Section 6-3-2, page 1407 in Job Card D/R A311 - AWS Unit), and re-connect it to all the cables (refer to Section 8, page 1414 in Job Card D/R A311 - AWS Unit). 22. Reinstall the Omega Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 23. Reinstall the Top Cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 24. Reinstall the X-ray Console. 8 COMPLETION Ensure that the newly installed CD-ROM is correctly configured, as follows: 1. Power on the Senographe system, and login as the sdc user. 2. Insert a blank CD-ROM in the new CD-ROM drive. 3. From the Browser, click the CD-R icon and select Query in the drop-down menu. 4. The blank CD-ROM should be recognized by the Query. If the blank CD-ROM is not recognized, check connections, and restart the AWS. Page no. 1461 JC-DR-A-316.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A316 - SB-150 CD-ROM Drive This page is blank. Chapter 9 Page no. 1462 JC-DR-A-316.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A317 - Radiation Screen Job Card D/R A317 - Radiation Screen 1 Chapter 9 SUPPLIES Radiation screen 2 APPLICABILITY This Job Card is only applicable to Control Stations higher than V1. 3 TOOLS Standard Tool Box 4 REQUIRED EFFORT Personnel: 2 Field Engineers Time: 60 minutes 5 SAFETY PRECAUTIONS Power to the system must be off before beginning the procedure. 6 PRE-REQUISITES The Control Station have been secured to the floor in its correct position. 7 PROCEDURE 7-1 Disassembly 1. Remove the main frame-radshield joint (1) between the radiation screen and the frame. 1 2 3 2. Use a screwdriver to remove the eight screw covers (2) from the fixing points of the edge pinches (3). 3. According to the site configuration, remove the edge pinch on the side where the radiation screen Page no. 1463 JC-DR-A-317.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A317 - Radiation Screen can be removed. To do this, remove the two screws (5) and loosen the two screws (4). 4 5 4. Remove the edge pinch and pinch plate. 5. Loosen the two screws (4) on the opposite edge pinch. 6. Slide out the radiation screen. Chapter 9 Page no. 1464 JC-DR-A-317.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A317 - Radiation Screen 7-2 Reassembly 1. Carefully put the new radiation screen (1) in place. The vertical felt bands (2) must be located towards the back of the Control Station. 1 2 2. Carefully introduce one pinch plate (3) between the edge pinch and the radiation screen. 3 4 3. Tighten with moderation the two screws (4). Page no. 1465 JC-DR-A-317.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A317 - Radiation Screen 4. Reinstall the edge pinch that you previously removed and secure it with two screws (5). 5 5. Carefully introduce one pinch plate (6) between the edge pinch and the radiation screen. 6 7 6. Tighten with moderation the two screws (7). 7. Install the main frame-radshield joint (8) between the radiation screen and the frame. 8 9 8. Reinstall the eight screw covers (9) to the fixing points of the edge pinches. Chapter 9 Page no. 1466 JC-DR-A-317.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A317 - Radiation Screen 7-3 Completion Put the old radiation screen in the physical packaging of the new radiation screen. Dispose the old radiation screen as unsorted municipal waste that must be collected separately. Page no. 1467 JC-DR-A-317.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A317 - Radiation Screen This page is blank. Chapter 9 Page no. 1468 JC-DR-A-317.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A318 - LCD Monitor Job Card D/R A318 - LCD Monitor 1 Chapter 9 SUPPLIES 1. Examine the label on the rear of the LCD Monitor connected to the Senographe system to determine whether which monitor exists. 18" LCD Monitor has: • 18 as the first two numbers after SMD in the Item code. • 2403951-4 as the Model No. • 2403952-4 as the FRU No. 18" LCD Monitor Label 19" LCD Monitor has: • 19 as the first two numbers after SMD in the Item code. • 5148720-4 as the Model No. 19" LCD Monitor Label 21" LCD Monitor has EIZO on the label. 21" 3MP LCD Monitor Label 2. Order the appropriate LCD Monitor as follows: ADS Version Existing Monitor New Monitor Below 53.40 (pre-Penduick) 18" LCD Monitor (2403952-4) 19" LCD Monitor with BNC connectors (5397967) 19" LCD Monitor (5148720-4) 19" LCD Monitor (5148720-4) Page no. 1469 JC-DR-A-318.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A318 - LCD Monitor ADS Version 53.40 or above (Penduick or above) Existing Monitor New Monitor 18" LCD Monitor (2403952-4) 19" LCD Monitor with BNC connectors (5397967) 19" LCD Monitor (5148720-4) 19" LCD Monitor (5148720-4) 21" 3MP LCD Monitor (5370904) 21" 3MP LCD Monitor (5370904) Note: For Penduick and above, a system with a 19” LCD Monitor can be upgraded to the 21" 3MP LCD Monitor if the customer has paid for that option. 2 APPLICABILITY Three types of Rotative Arm Sets exist, as follows: • Ergotron A (introduced with V1 Control Stations) - contains one rotative arm support and two extension (rotative) arms • Ergotron B (introduced with V2 Control Stations) - contains one rotative arm support and two extension (rotative) arms • Sisfle (introduced with V3/V4 Control Stations) - contains one rotative arm support and one extension (rotative) arm The procedure used in this Job Card vary according to the type of rotative arm you have. This Job Card is only applicable to the V2/V3/V4 Control Station. 3 TOOLS Standard Tool Box 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 15 minutes 5 SAFETY PRECAUTIONS WARNING Before beginning work, shut down the equipment and switch off the Generator hospital supply circuit breaker. Lock it in the off position or mark it clearly with a warning sign to prevent others from applying power. Never switch off at the UPS except in emergency (risk of data loss). 6 PREREQUISITES None 7 • • PROCEDURE If you are changing an 18" or 19" LCD Monitor for another 18" or 19" LCD Monitor, refer to section 71, 18" and 19" Monitors. If you are changing an 21" 3MP LCD Monitor for another 21" 3MP LCD Monitor, refer to section 7-2, 21" 3MP Monitor. Chapter 9 Page no. 1470 JC-DR-A-318.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A318 - LCD Monitor • If you are upgrading an 18" or 19" LCD Monitor to a 21" 3MP LCD Monitor, refer to section 7-1-1, Disassembly - 18" and 19" Monitors to remove the 18" or 19" LCD Monitor, and section 7-2-2, Reassembly - 21" 3MP Monitors to install the 21" 3MP LCD Monitor. Note: You can only upgrade 18" or 19" LCD Monitor to a 21" 3MP LCD Monitor if the Senographe system has a V3 Control Station with a Sisfle Arm, running ADS 54.30 or above or a V4 Control Station. Page no. 1471 JC-DR-A-318.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A318 - LCD Monitor 7-1 18" and 19" Monitors For the V2/V3 Control Stations, two types of Rotative Arm Sets exist, as follows: • Ergotron B - contains one rotative arm support and two extension (rotative) arms • Sisfle - contains one rotative arm support and one extension (rotative) arm For the V4 Control Stations, only the Sisfle arm exists. When appropriate, the steps below show images for both arms. 7-1-1 Disassembly - 18" and 19" Monitors 1. If necessary, cut the cable tie that secures the monitor harness to the back of the LCD monitor. 2. Unscrew the screw (1) (screwdriver) which secures the monitor cable protecting plate (2) and remove the cable protecting plate. Ergotron B Arm Sisfle Arm 1 2 1 2 3. Disconnect the power supply cable (3) from the monitor. 4. Remove the screw securing the power supply cable clamp (4) (screwdriver) and remove the power supply cable. 5. Disconnect the video connection as follows: • On V2 Control Stations, disconnect the five BNC cables and ensure that the BNC T Adapter and Chapter 9 Page no. 1472 JC-DR-A-318.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A318 - LCD Monitor 75 Ohm BNC Terminator remain connected to the black cable. Red Green Blue Grey Black plus BNC T Adapter and BNC Terminator 4 5 3 • On V3/V4 Control Stations, connect the DVI cable. DVI 4 5 3 6. Disconnect the ground cable (5) (screwdriver). 7. Remove the four inner screws (6) securing the monitor (3 mm allen wrench). Ergotron B Arm Sisfle Arm 6 6 6 CAUTION Do not remove the four external screws. 8. Carefully slide the monitor up the support to remove it from the rotative arm. Page no. 1473 JC-DR-A-318.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A318 - LCD Monitor 7-1-2 Reassembly - 18" and 19" Monitors If this intervention concerns the replacement of the monitor execute all the following steps, otherwise go directly to step 4. 1. Remove the four screws (1 and 2) securing the screen plate to the old monitor. The screen plate and four screws are used for fixing the new monitor to the rotative arm. 1 2 2. Place the new monitor on a protected surface. Fix the screen plate to the monitor using washers and two 20 mm screws (1) on the top, and two 16 mm screws (2) on the bottom. 1 2 3. Fix the screen plate to the new monitor using two screws of 20 mm length (1) on the top and two screws of 16 mm length (2) on the bottom. Chapter 9 Page no. 1474 JC-DR-A-318.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A318 - LCD Monitor 4. Carefully slide the monitor on to the support at the end of the rotative arm. 5. Fix the sliding pivot with the monitor using the four inner screws of 8 mm length (3) (3 mm allen wrench). Sisfle Arm Ergotron B Arm 3 3 3 Page no. 1475 JC-DR-A-318.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A318 - LCD Monitor 6. Unscrew the screw (4) (screwdriver) which secures the monitor cable protecting plate (5) and remove the cable protecting plate. Ergotron B Arm Sisfle Arm 4 4 5 5 7. Connect the ground cable (6) (screwdriver). 8. Connect the video connection as follows: • On V2 Control Stations, connect the five BNC cables. Insert a BNC T Adapter and a 75 Ohm BNC Terminator between the black cable and the monitor connector. Red Green Blue Grey Black plus BNC T Adapter and BNC Terminator 8 6 7 Chapter 9 Page no. 1476 JC-DR-A-318.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A318 - LCD Monitor • On V3/V4 Control Stations, connect the DVI cable. DVI 8 6 7 9. Connect the power supply cable (7) and secure it with a cable clamp (8). 10. Re-install the cable protecting plate (5) while ensuring that the cables pass through the exit without being trapped, and tighten the securing screw (4) (screwdriver). 11. At 17 cm away from the right edge (looking from behind), secure the monitor harness to the back of the LCD monitor with a black cable tie (9). 9 17 cm 12. Perform a monitor collision check as follows: • For the Ergotron B arm, check that the three stop brackets and three stop screws (10) are correctly positioned to avoid a collision with the radiation screen. 10 Ergotron Arm Page no. 1477 JC-DR-A-318.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A318 - LCD Monitor • For the Sisfle arm, check that the stop bracket and stop bracket screw (10) is correctly positioned to avoid a collision with the radiation screen. 10 Sisfle Arm Chapter 9 Page no. 1478 JC-DR-A-318.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A318 - LCD Monitor 7-2 21" 3MP Monitor 7-2-1 Disassembly - 21" 3MP Monitors 1. Cut and remove the cable tie (1) that secures the power cable to the back of the LCD monitor. 2. Disconnect the power supply cable (2) from the monitor. 3. Disconnect the DVI cable (3). 3 2 1 4. Remove the four inner screws (4) securing the monitor (3 mm allen wrench). 4 4 CAUTION Do not remove the four external screws. 5. Carefully slide the monitor up the support to remove it from the rotative arm. Page no. 1479 JC-DR-A-318.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A318 - LCD Monitor 7-2-2 Reassembly - 21" 3MP Monitors If this intervention concerns the replacement of the monitor execute all the following steps, otherwise go directly to step 3. 1. Remove the four screws (1 and 2) securing the screen plate to the old monitor. The screen plate and four screws are used for fixing the new monitor to the rotative arm. 1 2 2. Place the new monitor on a protected surface. Fix the screen plate to the monitor using washers and two 20 mm screws (1) on the top, and two 16 mm screws (2) on the bottom. 2 1 3. Carefully slide the monitor on to the support at the end of the rotative arm. Chapter 9 Page no. 1480 JC-DR-A-318.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A318 - LCD Monitor 4. Fix the sliding pivot with the monitor using the four inner screws of 8 mm length (3) (3 mm allen wrench). 3 3 5. Connect the DVI cable (4). 4 5 6 6. Connect the power supply cable (5) and secure it with a cable tie (6). 7. Perform a monitor collision check. Check that the stop bracket and stop bracket screw (7) is correctly Page no. 1481 JC-DR-A-318.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A318 - LCD Monitor positioned to avoid a collision with the radiation screen. 7 8 • • • COMPLETION If Stereo or 2D Biopsy Optical Localizer option exists, calibrate the newly installed LCD Monitor according to Job Card ELE A043 - AWS Monitor Calibration on page 729. If you have upgraded from an 18" or 19" LCD Monitor to a 21" 3MP LCD Monitor, perform all of Job Card ELE A008 - Configuring the 21-inch 3MP Monitor on page 549 so that: - the ADS software is correctly configured for the 21" 3 MP Monitor - the 21" 3 MP Monitor mode is configured to use DICOM mode - 21" 3 MP Monitor buttons a locked If you have changed an existing 21" 3 MP Monitor, perform section 7-2, Monitor Mode Configuration on page 553 in Job Card ELE A008 - Configuring the 21-inch 3MP Monitor, so that: - the 21" 3 MP Monitor mode is configured to use DICOM mode - 21" 3 MP Monitor buttons a locked The LCD Monitor contains Mercury, therefore properly dispose of the LCD Monitor in accordance to your local laws. Chapter 9 Page no. 1482 JC-DR-A-318.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A319 - Rotative Arm Job Card D/R A319 - Rotative Arm Chapter 9 Three types of Rotative Arm Sets exist, as follows: • Ergotron A (introduced with V1 Control Stations) - contains one rotative arm support and two extension (rotative) arms. Superseded by Ergotron B arm. You cannot order the Ergotron A arm. • Ergotron B (introduced with V2 Control Stations and early V3 Control Stations) - contains one rotative arm support and two extension (rotative) arms • Sisfle (introduced with V3/V4 Control Stations) - contains one rotative arm support and one extension (rotative) arm The procedure, tools, and supplies used in this Job Card vary according to the type of rotative arm you are changing. 1 SUPPLIES Ergotron B Rotative Arm or Sisfle Rotative Arm 2 • • TOOLS Standard Tool Box Sisfle Rotative Arm Installation Tool (FE supply) 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 1 hour 4 SAFETY PRECAUTIONS WARNING Before beginning work, shut down the equipment and switch off the Generator hospital supply circuit breaker. Lock it in the off position or mark it clearly with a warning sign to prevent others from applying power. Never switch off at the UPS except in emergency (risk of data loss). 5 • • • • PREREQUISITES Unplug and remove the X-ray Console Remove the Top cover (refer to Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503) Remove the Omega cover (refer to Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503) Remove the LCD monitor (refer to Job Card D/R A318 - LCD Monitor on page 1469) Page no. 1483 JC-DR-A-319.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A319 - Rotative Arm 6 PROCEDURE FOR ERGOTRON B ARM 6-1 Disassembly of Ergotron B Arm 1. Carefully extract the harness (1) from the Rotative Arm and release them from the Monitor and Mouse Support (2). 1 2 2. While holding the Monitor and Mouse Support (2), remove the two screws (3) securing it (allen wrench 3/32''). 2 Chapter 9 3 Page no. 1484 JC-DR-A-319.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A319 - Rotative Arm 3. Remove the plastic blanking plug (3) from the corner of the rotative arm (rotative arm support side). 3 4. Unscrew the bolt (4) (ratchet wrench with 13 mm socket) and remove the rotative arm. 4 6-2 Reassembly of Ergotron B Arm 1. On the rotative arm support, check the presence of the axis (1) and stop bracket (2) (alignment tab is positioned on the Control Station side). 1 2 Page no. 1485 JC-DR-A-319.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A319 - Rotative Arm 2. Check the presence of the three stop screws (3) on the rotative arm. 3 3 3. Attach the rotative arm to the axis (4). Secure the rotative arm with the bolt (5) (torque wrench with 13 mm socket, torque 6.5 N.m) and the four washers according to the following illustration. 5 4 4. Reinstall the plastic blanking plug (6) on the corner of the rotative arm. 6 Chapter 9 Page no. 1486 JC-DR-A-319.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A319 - Rotative Arm 5. Reinstall the Monitor and Mouse Support with the two screws (7) (allen wrench 3/32''). 7 6. Insert the harness (8) into the rotative arm. 8 7. Reinstall the LCD Monitor (refer to Job Card D/R A318 - LCD Monitor on page 1469). 8. Check that the three stop brackets (9) are correctly positioned to avoid collision with the radiation screen. 9 9. Reinstall the Omega cover then Top cover (refer to Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 10. Reinstall and reconnect X-ray Console. Page no. 1487 JC-DR-A-319.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A319 - Rotative Arm 7 PROCEDURE FOR SISFLE ARM 7-1 Disassembly of Sisfle Arm 1. Carefully pull on the upper silicone mask (1) to remove it from the rotative arm. Store the upper silicone mask in a clean place. 1 2. Carefully pull on the lower silicone mask (2) to remove it from the rotative arm support. Store the lower silicone mask in a clean place. 2 3. Disconnect the mouse cable from the ADS computer. 4. Cut the cable ties that secure the monitor cables and mouse cable to the Control Station framework Chapter 9 Page no. 1488 JC-DR-A-319.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A319 - Rotative Arm (3) and harness (4). 4 3 5. Carefully pull the harness (5) from the upper and lower parts of the rotative arm. 7 5 6. Extract the mouse cable (6) from the hole in the harness, and from the opening of the monitor sup- Page no. 1489 JC-DR-A-319.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A319 - Rotative Arm port (7). Remove the mouse and store it in a clean place. 6 7. Extract the harness from the opening of the monitor support (7). To ease the harness extraction, pull the harness back from the monitor cables and remove the monitor cables from opening of the monitor support in the following order: • Ground cable • DVI video cable (for V3/V4 Control Stations) or BNC video cables (for V2 Control Stations) • Power cable 8. Remove the monitor cables (8) from the harness, and put the harness in a clean place. 8 9. Pass each of the monitor cables through the opening of the rotative arm support and store them on top of the Control Station keyboard. To do this easily, proceed as described in the following substeps. Chapter 9 Page no. 1490 JC-DR-A-319.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A319 - Rotative Arm a. Thread the ground cable through the opening of the rotative arm support. b. Thread the power cable through the opening of the rotative arm support as shown below. Page no. 1491 JC-DR-A-319.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A319 - Rotative Arm c. On V3/V4 Control Stations, thread the ferrite ring (9) of the DVI video cable inside the rotative arm support. While keeping the DVI connector outside (10) move the DVI video cable to the bottom of the rotative arm support. 9 10 d. On V3/V4 Control Stations, thread the DVI video cable through the opening of the rotative arm support as shown below. Chapter 9 Page no. 1492 JC-DR-A-319.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A319 - Rotative Arm e. On V2 Control Stations, thread each of the BNC video cables through the rotative arm support as shown below. 10. Remove the four screws (11) securing the rotative arm support (5 mm allen wrench) and remove it. 11 11 7-2 Reassembly of Sisfle Arm 1. Install the new rotative arm support on the opposite side of the Control Station and secure it with the same four screws (5 mm allen wrench). To do this easily, use the Sisfle Arm Installation Tool with the following sub-steps: a. Put the two threaded rods the Sisfle Arm Installation Tool into the lower two threads (2). Screw the two threaded rods (1) in a clockwise direction until they no longer move. The right-hand side Page no. 1493 JC-DR-A-319.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A319 - Rotative Arm rod will have some of its thread exposed, as illustrated below. 2 1 b. Slide lower holes of the rotative arm support onto the two threads. Push the acrylic support block (3) from the Sisfle Arm Installation Tool on to the two threaded rods so that the rotative arm is supported. 3 Chapter 9 Page no. 1494 JC-DR-A-319.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A319 - Rotative Arm c. Attach the top two screws (4) to secure the top of the rotative arm support (5 mm allen wrench). 4 5 d. Carefully pull the acrylic support block to remove it from the two threaded rods. Unscrew the two threaded in an anti-clockwise direction to remove them from the Control Station framework. e. Attach the bottom two screws (5) to secure the top of the rotative arm support (5 mm allen wrench). f. Use the torque wrench to tighten the four screws to 9.5 Nm ± 0.5 Nm. g. Apply Blue Loctite 243 around the heads of the four screws. 2. Pass each of the monitor cables that you stored on top of the Control Station keyboard through the opening of the rotative arm support. To do this easily, proceed as described in the following substeps. a. On V3/V4 Control Stations, thread the DVI video cable through the opening of the rotative arm support as shown below. 7 6 b. On V3/V4 Control Stations, thread the ferrite ring (6) of the DVI video cable inside the rotative arm support. While keeping the DVI connector outside (7) move the DVI video cable to the top of the Page no. 1495 JC-DR-A-319.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A319 - Rotative Arm rotative arm support. 7 6 c. On V2 Control Stations, thread each of the BNC video cables through the rotative arm support as shown below. d. Thread the power cable through the opening of the rotative arm support as shown below. Chapter 9 Page no. 1496 JC-DR-A-319.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A319 - Rotative Arm e. Thread the ground cable through the opening of the rotative arm support. 3. Thread the monitor cables (8) through the harness. Ensure that the monitor cables do not cross each other, as shown below. 8 4. Put the harness through the opening of the monitor support (9). To do this, pull the harness back from the monitor cables and insert the monitor cables through the opening of the monitor support in the following order: • Power cable • DVI video cable (for V3/V4 Control Stations) or BNC video cables (for V2 Control Stations) • Ground cable 10 9 10 Page no. 1497 JC-DR-A-319.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A319 - Rotative Arm 5. Distribute evenly (10) the harness over the monitor cables on both sides of the monitor support. 6. Place the mouse at the back of the mouse support (so that there is enough cable for use of the mouse on the entire mouse support). 7. Use pointed nose pliers to create an opening in the harness at 27 cm from the end of the harness. 27 cm 8. Route the mouse cable through the opening in the harness, so that it leaves the other end of the harness. Then route the mouse cable through the rotative arm support entrance into the Control Station. Chapter 9 Page no. 1498 JC-DR-A-319.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A319 - Rotative Arm 9. Ensure that the length of each of the monitor cables leaving the harness are at the distances as specified below. Secure the harness to the monitor cables with a cable tie located at 1 cm from the end of the harness. Monitor video cable: 26 cm from harness end. Monitor power cable: 26 cm from harness end. Monitor earth cable: 6 cm from harness end. 26 cm 6 cm 10. Reinstall the LCD Monitor (refer to Job Card D/R A318 - LCD Monitor on page 1469). 11. Ensure that the rotative arm (11) and rotative arm support (12) are aligned in the same plane (see below). Carefully put the harness inside the rotative arm and rotative arm support. 12 11 Aligned in the same plane. 12. Insert the upper silicone mask (shorter of the two) (14) into the rotative arm. The rounded edge of the silicone mask must point outwards. 13 Page no. 1499 JC-DR-A-319.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A319 - Rotative Arm 13. Insert the lower silicone mask (longer of the two) (14) into the rotative arm. The rounded edge of the silicone mask must point outwards. 14 14. Reconnect the mouse to the ADS computer. 15. Ensure that the monitor cables have sufficient slack (15) within the Control Station so that they can move. This ensures that the movement of the monitor cables are not inhibited when the rotative arm is turned. Secure the harness to the monitor cables and mouse cable with a cable tie at 1 cm from the end of the harness (16). Secure the monitor cables and mouse cable to the Control Station framework with a cable tie (17). 16 15 17 Chapter 9 Page no. 1500 JC-DR-A-319.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A319 - Rotative Arm 16. Turn the rotative arm though all extremes, and check that the harness, monitor cables, and mouse cable are free to move as indicated below. 17. When moving the rotative arm through the extreme positions, check that the stop bracket screw (18) is correctly positioned to avoid a collision with the radiation screen. 18 18. Reinstall the Omega cover then Top cover (refer to Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 19. Reinstall and reconnect X-ray Console. Page no. 1501 JC-DR-A-319.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A319 - Rotative Arm This page is blank. Chapter 9 Page no. 1502 JC-DR-A-319.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A321 - IDC Computer Job Card D/R A321 - IDC Computer 1 • Chapter 9 SUPPLIES IDC Computer - Dione 4 or Dione 5, depending on your system level as follows: - Go to the Service Desktop home page (see Launching the Service Desktop on page 120). - Consult Table 1 on page 63 in the section Component FW/SW to ADS Version compatibility Matrix on page 63. Determine the system level from the ADS/IDC/Generator CPU versions displayed on the Service Desktop home page, and by consulting Table 1 on page 63. The system level will be defined by one of the System Level (Model Number) columns in Table 1 on page 63. - If your system is at pre-Penduick level, order the Dione 4 (2375961) - If your system is at Penduick or above level, order the Dione 5 (5324091) Floppy disk or CD-ROM with parameters for the currently installed image receptor • 2 TOOLS Standard Tool Kit 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 90 minutes 4 SAFETY PRECAUTIONS WARNING Before beginning work, shut down the equipment correctly and switch OFF the Senographe system hospital supply circuit breaker. Lock it in the OFF position and mark it clearly with a warning sign to prevent others from applying power. 5 • • PREREQUISITES Remove Control Station omega cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. Backup the system configuration to a floppy diskette or a CD-R. See Job Card ELE A052 - Back-up/ Restore Procedure on page 771. If a current backup is not available, it will be necessary to carry out all detector calibration procedures after the replacement. Page no. 1503 JC-DR-A-321_DS.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A321 - IDC Computer 6 PROCEDURE 6-1 Summary The following list summarizes the steps described in this document. These steps must be followed when installing a replacement IDC Computer: 1. Disassembly (removal) of the existing IDC Computer. 2. Reassembly (installation) of the replacement IDC Computer. 3. Reload IDC software from the IDC Application Software CD-ROM used for the current installation. 4. Restore the detector calibration files by applying a "Restore IDC", see Job Card ELE A052 - Back-up/ Restore Procedure on page 771. 5. Select Service desktop/Utilities and perform the Detector Replacement procedure. 6. Reset the IDC Computer by powering it OFF/ON. Chapter 9 Page no. 1504 JC-DR-A-321_DS.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A321 - IDC Computer 6-2 Disassembly of IDC Computer on V1/V2 Control Stations 1. Locate the IDC Computer (1) inside the Control Station. 1 2. Disconnect all cables from the IDC Computer rear panel. Note: Note locations of disconnected cables. 3. Disconnect Ground cable (screwdriver). 4. Disconnect the fiber optic cables. 5. For V1 Control Stations, undo the Velcro strips (2) securing the IDC Computer to the Control Station framework. 2 Page no. 1505 JC-DR-A-321_DS.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A321 - IDC Computer 6. For V2 Control Stations: a. disconnect the front two allen (3) screws that attach the IDC Computer to the Control Station framework (2.5 mm allen wrench). 3 b. Disconnect the back two allen (4) screws that attach the IDC Computer to the Control Station framework (2.5 mm allen wrench). 4 7. Remove the defective IDC Computer from the Control Station. Chapter 9 Page no. 1506 JC-DR-A-321_DS.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A321 - IDC Computer 6-3 Disassembly of IDC Computer (Dione4 version) on V3 Control Stations 1. Locate the IDC Computer (1) and UPS unit (2) inside the Control Station. 1 2. 3. 4. 5. 2 Make a note of all the cables connected to the UPS unit rear panel. Disconnect all the power cables and data cable from the UPS unit rear panel. Disconnect Ground cable (cross-head screwdriver) from the UPS unit rear panel. Open the velcro straps (3) securing the UPS to the Control Station. 3 6. Remove the UPS unit from the Control Station by lifting it vertically from the framework and pulling it towards you. Page no. 1507 JC-DR-A-321_DS.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A321 - IDC Computer 7. .Disconnect the allen screw and bolt (4) connecting the UPS base plate to the L-shaped bracket (2.5 mm allen wrench). 4 5 8. Disconnect the four allen screws and bolts (5) connecting the UPS base plate to the Control Station framework (5 mm allen wrench and 10 mm open ended wrench). 9. Remove the UPS base plate from the Control Station frame to expose the IDC Computer. 10. Disconnect all cables from the IDC Computer rear panel. Note: Note locations of disconnected IDC cables. 11. Disconnect Ground cable (screwdriver) from the IDC Computer rear panel. 12. Disconnect the fiber optic cables from the IDC Computer rear panel. 13. Disconnect the power cables and ground cable from the UPS unit rear panel. 14. Disconnect the front two allen (6) screws that attach the IDC Computer to the Control Station frame- Chapter 9 Page no. 1508 JC-DR-A-321_DS.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A321 - IDC Computer work (2.5 mm allen wrench). 6 15. Disconnect the back two allen (7) screws that attach the IDC Computer to the Control Station framework (2.5 mm allen wrench). 7 16. Remove the defective IDC Computer from the Control Station. Page no. 1509 JC-DR-A-321_DS.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A321 - IDC Computer 6-4 Disassembly of IDC Computer (Dione5 version) on V3/V4 Control Stations 1. Locate the IDC Computer (1) and UPS unit (2) inside the Control Station. 1 2. 3. 4. 5. 2 Make a note of all the cables connected to the UPS unit rear panel. Disconnect all the power cables and data cable from the UPS unit rear panel. Disconnect the ground cable (cross-head screwdriver) from the UPS unit rear panel. Open the velcro straps (3) securing the UPS to the Control Station. 3 6. Remove the UPS unit from the Control Station by lifting it vertically from the framework and pulling it towards you. Chapter 9 Page no. 1510 JC-DR-A-321_DS.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A321 - IDC Computer 7. If it exists (i.e. on pre-Penduick V3 Control Stations), disconnect the allen screw and bolt (4) connecting the UPS base plate to the L-shaped bracket (2.5 mm allen wrench). 4 5 Pre-Penduick V3 Control Stations 5 Penduick and above V3 Control Stations and V4 Control Stations 8. Disconnect the four allen screws (5) connecting the UPS base plate to the Control Station framework (5 mm allen wrench). 9. Remove the UPS base plate from the Control Station frame to expose the IDC Computer. 10. Disconnect all cables from the IDC Computer rear panel. Page no. 1511 JC-DR-A-321_DS.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A321 - IDC Computer 11. Disconnect the Ground cable (screwdriver) from the IDC Computer rear panel. 12. Disconnect the front two allen (6) screws that attach the IDC Computer to the Control Station framework (4 mm allen wrench). 6 13. Disconnect the back two allen (7) screws that attach the IDC Computer to the Control Station framework (4 mm allen wrench). 7 14. If it exists (i.e. on pre-Penduick V3 Control Stations), remove the allen screw (2.5 mm allen wrench) that attaches the left-hand side L-bracket (8) to the Control Station framework, and remove the L- Chapter 9 Page no. 1512 JC-DR-A-321_DS.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A321 - IDC Computer bracket. Access to the allen screw is to the left-hand side, behind the switch. 8 15. Remove the defective IDC Computer and its baseplate from the Control Station. Page no. 1513 JC-DR-A-321_DS.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A321 - IDC Computer 16. Remove the six allen screws (9) that attach the baseplate to the IDC (2.5 mm allen wrench). 9 9 6-5 Reassembly of IDC Computer Reverse the disassembly procedure. See the table and illustration below for the IDC rear panel connections. See Job Card D/R A331 - UPS on page 1521 for the UPS rear panel connections. Chapter 9 Page no. 1514 JC-DR-A-321_DS.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A321 - IDC Computer Reference Cable Label/Description Reference Cable Label/Description 1 IDC - Gantry Serial Link RT (1) 2240227 or 2244615 5 To Ethernet Switch: 2389288-2 on Penduick and above systems or 2389288 on Pre-Penduick systems 2 IDC - Gantry Conditioner Link 2226612 6 AC mains 3 Detector Power Supply 2226621 7 Optical Fiber cables (to detector) 4 IDC - Gantry Serial Link RT 2240227 or 2246615 8 Tray ground wire Dione4 7 4 5 2 3 6 1 Dione5 6 3 1 7 4 5 2 Note: For Dione5, an empty Ethernet port exists to the left hand side of the USB ports. The Ethernet cable from the switch must be connected to the lowest Ethernet port, which is to the left hand side of the IDC - Gantry Conditioner Link. Page no. 1515 JC-DR-A-321_DS.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A321 - IDC Computer 6-6 Software Restore To reload the IDC software, follow all the instructions given in the Senographe DS IDC Application Software booklet. 7 COMPLETION Perform the steps defined in Software Backup Kit-IDC on page 822. Chapter 9 Page no. 1516 JC-DR-A-321_DS.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A322 - RJ-45 Service Network Patch Panel Job Card D/R A322 - RJ-45 Service Network Patch Panel 1 Chapter 9 SUPPLIES RJ-45 Service Network Patch Panel 2 APPLICABILITY This Job Card is only applicable to Penduick and above V3 Control Stations and V4 Control Stations. 3 TOOLS Standard Tool Box 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 5 SAFETY PRECAUTIONS WARNING Before beginning work, shut down correctly the equipment and switch off the Senographe system hospital supply circuit breaker. Lock it in the off position or mark it clearly with a warning sign to prevent others from applying power. 6 PREREQUISITES None Page no. 1517 JC-DR-A-322.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A322 - RJ-45 Service Network Patch Panel 7 PROCEDURE 1. Carefully remove the caps from each corner of the Omega window. 1 2. Remove each of the four screws and plastic washers from each corner of the Omega window, and remove the Omega window to reveal the RJ-45 Service connector (1). 3. Disconnect the Ethernet cable from the rear of the socket of the RJ-45 Service Network Patch Panel. 4. Remove the two screws (2) (small cross-head screwdriver) securing the RJ-45 Service Network Patch Panel, and remove the RJ-45 Service Network Patch Panel. 2 Chapter 9 Page no. 1518 JC-DR-A-322.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A322 - RJ-45 Service Network Patch Panel 5. Insert the new RJ-45 Service Network Patch Panel into the Control Station framework, and secure it using the two screws (2) (small cross-head screwdriver). 6. Taking care to respect the orientation of the socket, firmly connect the Ethernet cable to the rear of the socket of the new RJ-45 Service Network Patch Panel. When the Ethernet cable is firmly in place it makes a clicking noise. 7. Use the following sub-steps to check that the newly connected RJ-45 Service Network Patch Panel is functional: a. Power up the Senographe system. b. Use a straight Ethernet cable to connect the network interface card (NIC) of your laptop to the RJ-45 Network Service Patch Panel in the Control Station. c. Configure your laptop according to Configure Laptop NIC on page 996 in Job Card DIAG A005 Error Log Retrieval to ensure that it is on the same network as the Senographe system. During this procedure, you ping the ADS (192.168.1.10) and IDC (192.168.1.20) to ensure that they are reachable. If the ADS and IDC are not reachable check the Ethernet connection to the rear side of the RJ-45 Service Network Patch Panel. 8. Use the four screws, washers and plastic caps to re-install the Omega window. 8 COMPLETION None Page no. 1519 JC-DR-A-322.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A322 - RJ-45 Service Network Patch Panel This page is blank. Chapter 9 Page no. 1520 JC-DR-A-322.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A331 - UPS Job Card D/R A331 - UPS 1 Chapter 9 SUPPLIES UPS 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS WARNING Before beginning work, shut down the equipment correctly and switch off the Senographe system hospital supply circuit breaker. Lock it in the off position or mark it clearly with a warning sign to prevent others from applying power. 5 PREREQUISITES Remove the Control Station Omega cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 6 PROCEDURE ON V1/V2 CONTROL STATIONS 6-1 Disassembly of the UPS on V1/V2 Control Stations 1. Locate the UPS unit (1) inside the Control Station. 1 2. Disconnect all cables from the UPS unit rear panel. Page no. 1521 JC-DR-A-331.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A331 - UPS Note: Note locations of disconnected cables. 3. Disconnect the ground cable (small screwdriver) located at the top of the UPS rear panel. 4. Remove the four screws (2) (two on both side - 5 mm allen wrench) securing the UPS to the Control Station. 2 2 5. Remove the defective UPS unit from the Control Station. Chapter 9 Page no. 1522 JC-DR-A-331.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A331 - UPS 6-2 Reassembly of New UPS Unit on V1/V2 Control Stations 1. Put the new UPS unit (1) inside the Control Station. 3 6 1 4 2 2 2. Attach the four screws (2) (two on both side - 5 mm allen wrench) to secure the UPS to the Control Station frame. 3. Connect the ground cable (3) (small screwdriver) to the top of the new UPS rear panel. 4. Connect all the power cables back to the new UPS rear panel. 5. Connect the communications cable (4) to the back of the new UPS rear panel. 6. The battery plug to the UPS is not connected at delivery time. Firmly connect the battery plug (6) to the battery on the newly installed UPS as shown below. UPS battery disconnected at delivery time Connect UPS battery as shown below 6 Page no. 1523 JC-DR-A-331.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A331 - UPS 7 PROCEDURE ON V3/V4 CONTROL STATIONS 7-1 Disassembly of the UPS on V3/V4 Control Stations 1. Locate the UPS unit (1) inside the Control Station. 1 2. Disconnect all cables from the UPS unit rear panel. Note: Note locations of disconnected cables. 3. Disconnect the Ground cable (cross-head screwdriver). 4. Open the velcro straps (2) securing the UPS to the Control Station. 2 Chapter 9 Page no. 1524 JC-DR-A-331.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A331 - UPS 5. Remove the defective UPS unit from the Control Station by lifting it vertically from the framework and pulling it towards you. 7-2 Reassembly of New UPS Unit on V3/V4 Control Stations 1. Put the new UPS unit (1) inside the Control Station. 1 2. Attach the velcro straps (2) to secure the UPS to the Control Station. 2 Page no. 1525 JC-DR-A-331.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A331 - UPS 3. Connect the ground cable (3) (small screwdriver) to the TVSS GND connector of the UPS rear panel. 3 6 3 6 4 5 7 4. Connect all the power cables (4) from the Control Station Components to the power output sockets on the UPS rear panel, as indicated below: IDC IDC AC MultiSocket ADS Monitor ADS Pre-Penduick V3 Control Stations Switch Penduick and above V3 Control Stations and V4 Control Stations 5. Connect the AC mains supply power cable (5) from to Generator to the power input socket on the UPS rear panel. 6. Connect the communications cable (6) to the UPS Monitor Port connector of the UPS rear panel. Chapter 9 Page no. 1526 JC-DR-A-331.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A331 - UPS 7. The battery plug to the UPS is not connected at delivery time. Firmly connect the battery plug (7) to the battery on the newly installed UPS as shown below. Connect UPS battery as shown below UPS battery disconnected at delivery time 7 8 COMPLETION Power up the Senographe system, and perform a UPS functional check according to UPS Function Check on page 1737, which is described in Job Card CHK A003 - UPS Batteries. Before sending the old UPS for recycling, ensure that the plug on the UPS has been disconnected from the battery as shown below). Plug Disconnected Old UPS from V3/V4 Control Stations Old UPS from V1/V2 Control Stations Page no. 1527 JC-DR-A-331.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A331 - UPS This page is blank. Chapter 9 Page no. 1528 JC-DR-A-331.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A332 - UPS Battery Replacement Job Card D/R A332 - UPS Battery Replacement 1 Chapter 9 SUPPLIES UPS Battery 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 4.5 hours 4 SAFETY PRECAUTIONS WARNING Before starting, shut down the equipment correctly and switch off the Senographe system hospital supply circuit breaker. Lock it in the off position or mark it clearly with a warning sign to prevent others from applying power. 5 PREREQUISITES Remove the Control Station Omega cover (see Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503). 6 PROCEDURE ON V1/V2 CONTROL STATIONS 6-1 Disassembly of the UPS Battery on a V1/V2 Control Station 1. Remove the UPS from the Control Station (see Job Card D/R A331 - UPS on page 1521, section 6-1, Disassembly of the UPS on V1/V2 Control Stations on page 1521). To disassemble the UPS battery, you must do the following: 1. Switch off the electrical power supply from the Mains Distribution Panel in the room. Wait 10 minutes for the Battery to discharge. Page no. 1529 JC-DR-A-332.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A332 - UPS Battery Replacement 2. Unplug the battery connector (1), located on the rear panel. 1 Note: Battery replacement is a safe procedure, isolated from electrical hazards. You may leave the UPS and load on for the following procedure. 3. Grasp the top edge of the bottom front cover and tilt it out. 4. Unhook the bottom section of the front cover from the chassis and set it aside. 5. Use a flat-blade screwdriver or a coin to remove the two battery door screws and open the door. 6. Grip the wires for the front set of batteries and pull firmly to disconnect the connector from the battery compartment. Chapter 9 Page no. 1530 JC-DR-A-332.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A332 - UPS Battery Replacement 7. Pull the white cord on the front battery connector to remove the batteries. 8. Set aside the foam spacer located between the batteries. 9. Reach into the battery compartment and grasp the white cord on the other battery connector. Pull firmly to disconnect the connector and remove the second set of batteries. CAUTION Be careful when removing the batteries since they are heavy. Batteries weigh 5.5 kg/12.1 pounds. 6-2 Reassembly of the New UPS Battery on a V1/V2 Control Station 1. Affix a paper label with the charging date on new batteries. 2. Slide the first set of new batteries into the unit. Hold the connector down below the top of the batteries and towards the door ; otherwise the assembly does not fit. 3. Guide the connector over the top of the batteries and press firmly to connect it to the rear connector of the battery compartment. 4. Small sparks at the battery connectors are normal during connection. 5. Set the foam spacer against the rear batteries to prevent the wires from being pinched. 6. Slide in the second set of batteries, then guide the connector over the batteries and press firmly to Page no. 1531 JC-DR-A-332.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A332 - UPS Battery Replacement connect it to the front connector of the battery compartment. 7. Close the battery door, replace the screws, and replace the lower front cover. 8. Dispose of the old battery according to local requirements at an appropriate recycling facility or return it to the supplier in the packing material for the new battery. 9. Re-plug the battery connector by pushing the tethered jumper plug into the corresponding port. 6-3 New Battery Charging 1. Connect the UPS directly to a compatible power supply voltage. 2. Press the button on the front panel to power the UPS. 3. Wait four hours for the new Battery to charge. 4. The battery charges to 90% capacity during the first four hours of normal operation. Do not expect full battery run capability during this initial charge period. 5. Affix a paper label with the charging date on battery. 2. Put the UPS unit back into the control station (see Job Card D/R A331 - UPS - section 6-2 Reassembly of the New UPS Battery on a V1/V2 Control Station on page 1531). 7 PROCEDURE ON V3/V4 CONTROL STATIONS 7-1 Disassembly of the UPS Battery on a V3/V4 Control Station 1. Remove the UPS from the Control Station (see Job Card D/R A332 - UPS Battery Replacement on page 1529, section 7-1, Disassembly of the UPS on V3/V4 Control Stations on page 1524). To disassemble the UPS battery, you must do the following: 1. Switch off the electrical power supply from the Mains Distribution Panel in the room. Wait 10 min- Chapter 9 Page no. 1532 JC-DR-A-332.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A332 - UPS Battery Replacement utes for the Battery to discharge.. 1 2. Unplug the battery connector (1), located on the rear panel. 3. Grasp the top of the front cover and tilt it out and down. 4. Unhook the bottom of the cover from the chassis and lift it upward to expose the battery door. Be careful not to strain the ribbon cable. Do not touch the exposed printed circuit board. Fold the front cover on top of the UPS as shown below. Page no. 1533 JC-DR-A-332.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A332 - UPS Battery Replacement 5. Use a flat-blade screwdriver or a coin to remove the two battery door screws and open the door. Grasp the tab and gently pull the battery out of the UPS. 6. Disconnect the battery leads. Loosen the connectors by gently wiggling them while pulling straight back from the battery connector. Chapter 9 Page no. 1534 JC-DR-A-332.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A332 - UPS Battery Replacement 7-2 Reassembly of the New UPS Battery on a V3/V4 Control Station 1. Affix a paper label with the charging date on new battery. 2. Connect the battery leads to the new battery. Note: Small sparks at the battery connectors are normal during connection. Connect the red wire to the positive (+) terminal and the black wire to the negative (–)terminal. 3. Slide the battery into the UPS. 4. Close the battery door, replace the battery compartment screws, and replace thefront cover. 5. Dispose of the old battery according to local requirements at an appropriate recycling facility or return it to the supplier in the packing material for the new battery. 6. Re-plug the battery connector by pushing the tethered jumper plug into the corresponding port. 7-3 New Battery Charging 1. Connect the UPS directly to a compatible power supply voltage. 2. Press the button on the front panel to power the UPS. 3. Wait four hours for the new Battery to charge. Note: The battery charges to 90% capacity during the first four hours of normal operation. Do not expect full battery run capability during this initial charge period. 2. Put the UPS unit back into the control station (see Job Card D/R A331 - UPS section 7-2 Reassembly of the New UPS Battery on a V3/V4 Control Station on page 1535). 8 COMPLETION Power up the Senographe system, and perform a UPS functional check according to UPS Function Check on page 1737 and a Battery Capacity Recalibration described in Job Card CHK A003 - UPS Batteries.. Use the front display panel picture and the chart below for more information about LED display and indicators Page no. 1535 JC-DR-A-332.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A332 - UPS Battery Replacement The following table lists the indicators and features with their respective descriptions / functions. Indicator Description Onlin The UPS is supplying utility power to the connected equipment. AVR Trim The UPS is compensating for a high utility voltage. AVR Boost The UPS is compensating for a low utility voltage. On Battery The UPS is supplying battery power to the connected equipment. Overload The connected loads are drawing more than the UPS power rating. Replace Battery / Battery Disconnected The battery is disconnected or must be replaced. Power On Press this button to turn on the UPS. (Read on for additional capabilities.) Power Off Press this button to turn off the UPS. Chapter 9 Page no. 1536 JC-DR-A-332.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A335 - AWS (U20) Motherboard Battery (V3 Control Stations only) Job Card D/R A335 - AWS (U20) Motherboard Battery (V3 Control Stations only) Chapter 9 1 SUPPLIES U20 Motherboard Battery (5334112) 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS None 5 PREREQUISITES None 6 PROCEDURE 1. Remove the X-ray Console. 2. Remove the Control Station top cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 3. Remove the Control Station omega cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 4. Remove the U20 Workstation from the Control Station (refer to section 6-3-1 in Job Card D/R A311 AWS Unit). 5. Turn the power switch on the back of the U20 chassis to the OFF position ( 0 ). 6. Loosen the two captive thumb screws located on the rear edge of the left side access panel. Page no. 1537 JC-DR-A-335.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A335 - AWS (U20) Motherboard Battery (V3 Control Stations only) 7. Slide the access panel approximately 1.5 cm toward the back of the workstation. 8. Tilt the top edge of the panel out, then lift the panel upward. 9. Carefully set the panel aside. 10. Gently lay the system on its right side on a stable, nonslip surface. 11. Pinch the battery latch together (squeezing away from the battery) until the battery pops out of the motherboard socket. 12. Lift the battery to remove it. 13. Insert a new battery with the positive sign (+) facing up. Tilt the battery into the battery connector, angling the battery under the battery latch. Slide the battery until it clicks into place. 14. Position the access panel so the lip on the inside bottom of the panel fits over the bottom chassis rail. Chapter 9 Page no. 1538 JC-DR-A-335.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A335 - AWS (U20) Motherboard Battery (V3 Control Stations only) 15. Pressing gently against the top of the access panel, slide the panel toward the front of the chassis. The access panel lies flat against the chassis, with no gaps between the two. 16. Tighten the two captive thumbscrews located on the rear lip of the panel. The access panel is installed flat against the chassis with the thumbscrews tightened. 17. Put the U20 Workstation back into the Control Station (refer to section 6-3-2 in Job Card D/R A311 AWS Unit), and re-connect it to all the cables (refer to section 6-3-2 in Job Card D/R A311 - AWS Unit). Turn the power switch on the back of the U20 chassis to the ON position ( I ). 18. Reinstall the Control Station omega cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 19. Reinstall the Control Station top cover. See Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503. 20. Reinstall the X-ray Console. 21. Power on the Senographe system from the X-ray Console. 22. If necessary, power on the U20 from button O located in front panel under the DVD-ROM drive. 23. Immediately press repeatedly the F2 key until you enter the Bios setup. 24. Use the cursor keys to select the Boot item. 25. Use the vertical cursor keys and + - keys to have the boot order as follows: Boot priority order: 1: IDE CD : DVD_model_name 2: PCI SATA1 : Hard_drive_model_name ... 26. Press the right cursor key to go into the Power item. Page no. 1539 JC-DR-A-335.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A335 - AWS (U20) Motherboard Battery (V3 Control Stations only) 27. In the last line “After Power Failure”, change the Off value to Power On: C State Configuration:[Disabled] Standby State: [S1&S3] Resume On Time: Resume Time: After Power Failure: [Off] [00:00:00] [Power On] 28. Use the cursor keys to select the Exit item, and choose Exit Saving Changes: Exit Saving Changes:[Enter] Note: Do not attempt to set the date and time directly in the BIOS. Use the Service Desktop instead, as described below. 29. From the ads console login: prompt that appears, enter root, and operator when prompted for the root password. 30. Halt the system, by entering: Halt 31. When message the Press any key to reboot appears, switch the U20 back button of the station to OFF. 32. Switch the U20 back button to ON. 33. After login prompt is displayed, check if the following message is displayed: Warning: Time-of-day chip unresponsive; dead batteries? If this message is displayed return to step 23. If this message is not displayed, continue to step 32. 34. From the ads console login: prompt that appears, enter sdc. 35. From the ADS login screen that appears login as clinical (password clinical). 36. From the Browser, click the Tools menu and select Service Desktop to launch the Service Desktop. 37. From the Service Desktop, click the Configuration icon. 38. Click the Configuration > General node. Chapter 9 Page no. 1540 JC-DR-A-335.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A335 - AWS (U20) Motherboard Battery (V3 Control Stations only) 39. Set the correct date and time in the yyyy mm dd and hh:mm:ss System Clock fields, respectively. 40. Click the Submit button to commit the updated date and time. The new date and time are written to the U20 motherboard BIOS. 41. Click the Exit button to close the Service Desktop. 42. Back in the Browser, click the the System Shutdown icon. The Senographe system automatically shuts down. 43. Power on the Senographe system from the X-ray Console. 44. Observe the end of the boot screen to ensure that the date and time on the system are now correct. 7 COMPLETION None Page no. 1541 JC-DR-A-335.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A335 - AWS (U20) Motherboard Battery (V3 Control Stations only) This page is blank. Chapter 9 Page no. 1542 JC-DR-A-335.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A401 - Generator CPU Board 400PL3 Job Card D/R A401 - Generator CPU Board 400PL3 1 Chapter 9 SUPPLIES Generator CPU Board 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 2 hours 4 SAFETY PRECAUTIONS No specific safety precautions are applicable. When handling circuit boards, take precautions against damage by ESD (electro-static discharge), by using for example an anti-static mat and an ESD strap. 5 PREREQUISITES CAUTION Generator parameters are saved in the NV-RAM of the Generator CPU Board. If possible, ensure that a backup of these parameters has been made before removing the board. If not, it will be necessary to reconfigure the Generator after changing the board. To back-up the NV-RAM of the Generator CPU Board, perform a full system back-up according to Job Card ELE A052 - Back-up/Restore Procedure on page 771. For Senographe systems that use AWS V43.0 or later (on the SB150) or AWS 53.0 or later (on the U20), or AWS 54.10 or later (on the Z400), consult the site System Configuration Form to determine the current AOP configuration for all three modes (DOSE, STD, and CNT) on the Generator. Page no. 1543 JC-DR-A-401.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A401 - Generator CPU Board 400PL3 6 PROCEDURE 6-1 Remove Existing EEPROMs Remove the existing EEPROMs from the Generator Board CPU as explained insection 7-1, Remove the Existing EEPROMs on the Generator CPU Board on page 1627 in Job Card D/R A415 - Generator Board CPU EEPROMs. 6-2 Removing the Original Generator CPU Board 1. Switch off the electrical power supply from the Mains Distribution Panel in the room. Apply an appropriate LOTO padlock and label. Wait 10 minutes for the components within the Generator to discharge. 2. Remove the Generator front panel (CPU side) to reveal the Generator CPU board 400PL3; refer to Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513. 1 Generator CPU Board 2 2 Generator Control Board 3. Remove the five screws (1) (4 mm allen wrench) that secure the Generator CPU board 400PL3 to the Generator cabinet. 4. Gently pull and forwards the Generator CPU board 400PL3 to remove it from the two gray connectors (2) on the Generator Command board. 6-3 Installing the New Generator CPU Board 1. Carefully push the new Generator CPU board 400PL3 in to the two gray connectors (1) on the Generator Command board. Ensure that the connections on the two gray connectors are fully secure and Chapter 9 Page no. 1544 JC-DR-A-401.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A401 - Generator CPU Board 400PL3 correctly seated. 2 Generator CPU Board Generator Control Board 1 1 2. Attach the five screws (2) (4 mm allen wrench) to secure the new Generator CPU board 400PL3 to the Generator cabinet. 3. Ensure that the red switch block has the following configuration. 1: 2: 3: 4: 5: 6: 7: 8: 6-4 OPEN OPEN OPEN OPEN OPEN OPEN OPEN CLOSED Install Existing EEPROMs on the New Generator CPU Board Install the existing EEPROMs that were removed from the old Generator CPU Board on to the new Generator CPU Board, according to section 7-2, Install New EEPROMs on the Generator CPU Board on page 1627 in Job Card D/R A415 - Generator Board CPU EEPROMs. 6-5 Restoring Generator Parameters 1. Switch on the Senographe electrical power. 2. Ensure that the LEDs at the top of the newly installed Genrator CPU board 400PL3 operate as follows: • Green DS1 (Test OK) : ON • Yellow DS4 (TXTTLA1) : Blinking Page no. 1545 JC-DR-A-401.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A401 - Generator CPU Board 400PL3 • Yellow DS5 (RXDA1) : Blinking 3. Before restoring the NV-RAM on the Generator CPU Board, you must erase the NV-RAM content. On the Generator CPU Board to the left of the battery, remove the X2 jumper for 10 seconds and plug it back into the X2 pins again in horizontal position. X2 4. Reinstall the Generator front panel (CPU side). 5. Restore Generator parameters as described in Job Card ELE A052 - Back-up/Restore Procedure on page 771. 6. Restoring the Generator parameters will restore all the parameters except the X-ray Tube Heater calibration. You must perform an automatic calibration of X-ray Tube Heater current in large and small focus. Refer to Job Card CAL A012 - X-Ray Tube Heater Current on page 1673. The small focus heater calibration requires a Mag stand or a Mag Stand simulator. 7. Because the NV-RAM was reset, the current language setting for the Generator was erased. You must re-configure the preferred language setting for the Generator according to section 4-2, Set Language in Job Card ELE A009 - Generator Configuration on page 561. Chapter 9 Page no. 1546 JC-DR-A-401.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A401 - Generator CPU Board 400PL3 7 COMPLETION If no Generator parameter backup is available, or the restore is not successful, the Generator must be reconfigured. If Generator reconfiguration is necessary: • Carry out the following calibrations: Calibrations - Checks Job Card Acquisition Image Chain Heating Current Calibration Job Card CAL A001 - Heater Current Scale Factor on page 1649 Bias Calibration Job Card CAL A003 - X-Ray Tube Focal Bias Voltage Scale Factor on page 1655 Tube mA Measurement Job Card CAL A009 - X-Ray Tube mA Measurement on page 1663 kV Scale Factor Job Card CAL A011 - Calibration of kV Scale Factor on page 1667 mAs X-ray Calibration Job Card CAL A012 - X-Ray Tube Heater Current on page 1673 Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 If IQ Tests not OK, repeat all calibrations from Bad Pixel. Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Use the same dosimeter as that used for CAL A046 AOP: Automatic Optimization of Parameters AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations from AOP Calibration. • • For Senographe systems that use AWS V43.0 or later (on the SB150) or AWS 53.0 or later (on the U20), or AWS 54.10 or later (on the Z400), if the Senographe system does not use the default AOP Classic (AOP A) tables configuration, restore as necessary the AOP configuration (see Job Card ELE A031 - AOP Configuration on page 693). For Senographe systems that use AWS 53.40 or later, which has the Stereotaxy option installed and does not use the default AOP Profile (AOP B) tables for AOP stereo mode, restore the following: - AOP Configuration according to Job Card IST A003 AOP Configuration, as described in the Senographe Essential Stereotaxy Service Manual. Page no. 1547 JC-DR-A-401.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A401 - Generator CPU Board 400PL3 This page is blank. Chapter 9 Page no. 1548 JC-DR-A-401.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A402 - Generator CPU Battery Job Card D/R A402 - Generator CPU Battery 1 • 2 Chapter 9 SUPPLIES Lithium battery TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 90 minutes 4 SAFETY PRECAUTIONS No specific safety precautions are applicable. 5 PREREQUISITES For Senographe systems that use AWS V43.0 or later (on the SB150) or AWS 53.0 or later (on the U20), determine the current AOP configuration for all three modes (DOSE, STD, and CNT) on the Generator (see Job Card ELE A031 - AOP Configuration, section 7-4-2, Checking the Configuration Set on the Generator on page 697). 6 PROCEDURE CAUTION Before removing Generator CPU board 400PL3, backup the Generator parameters. This ensures that these parameters (normally saved using battery power) are not lost while the battery is being changed. See Job Card ELE A052 - Back-up/Restore Procedure on page 771. Page no. 1549 JC-DR-A-402.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A402 - Generator CPU Battery 6-1 Removal of Generator CPU Battery and Installation of New Battery 1. Back up the system configuration to the AWS disk. See Job Card ELE A052 - Back-up/Restore Procedure on page 771. 2. Switch off the electrical power supply from the Mains Distribution Panel in the room. Apply an appropriate LOTO padlock and label. Wait 10 minutes for the components within the Generator to discharge. 3. Remove the generator front panel (CPU side) Job 400-PL3 Card PHY A042 - Remove/Reinstall Generator CovGenerator ers on page 513. CPU 4. Pull generator CPU board 400PL3 gently forward and board remove it. 5. Solder the new lithium battery in the free position (BT1 or BT2), respecting the polarities. 6. Unsolder the old battery. 7. Reinstall generator CPU board 400PL3 in its position Generator in the generator. Lithium 8. Reinstall the generator front panel (CPU side). CPU Battery 6-2 Functional Check 1. Switch on the Senographe electrical power. 2. Check that the message: SAVED MEMORY ERROR 071/08 is not displayed after initialization. 3. If the above message appears, restore the Generator parameters from the system backup located on the AWS disk (see Job Card ELE A052 - Back-up/Restore Procedure on page 771). Chapter 9 Page no. 1550 JC-DR-A-402.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A402 - Generator CPU Battery 7 COMPLETION In normal circumstances there is nothing to do. However, if the Generator configuration was lost in one of the following situations, the Generator must be reconfigured: • the original battery was too low before you arrived • a problem occured during the backup procedure and you failed to solder the battery correctly If Generator reconfiguration is necessary: • carry out the following calibrations: Calibrations - Checks Job Card Acquisition Image Chain Heating Current Calibration Job Card CAL A001 - Heater Current Scale Factor on page 1649 Bias Calibration Job Card CAL A003 - X-Ray Tube Focal Bias Voltage Scale Factor on page 1655 Tube mA Measurement Job Card CAL A009 - X-Ray Tube mA Measurement on page 1663 kV Scale Factor Job Card CAL A011 - Calibration of kV Scale Factor on page 1667 mAs X-ray Calibration Job Card CAL A012 - X-Ray Tube Heater Current on page 1673 Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 If IQ Tests not OK, repeat all calibrations from Bad Pixel. Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Use the same dosimeter as that used for CAL A046 AOP: Automatic Optimization of Parameters AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations from AOP Calibration. • For Senographe systems that use AWS V43.0 or later (on the SB150) or AWS 53.0 or later (on the U20), if the Senographe system does not use the default AOP Classic (AOP A) tables configuration, restore as necessary the AOP configuration (see Job Card ELE A031 - AOP Configuration on page 693). Page no. 1551 JC-DR-A-402.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A402 - Generator CPU Battery This page is blank. Chapter 9 Page no. 1552 JC-DR-A-402.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A403 - Capacitor Box Job Card D/R A403 - Capacitor Box 1 Chapter 9 SUPPLIES Capacitor box 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS Steps in this Job Card tell you when to take appropriate action to avoid electric shock. • Switch off the mains power supply. • Check the residual voltage (inverter supply). 5 PREREQUISITES None 6 PROCEDURE 6-1 Removal of Filtering Capacitors Refer to Illustrations1 and 2 at the end of this Job Card. 1. Switch off the electrical power supply from the Mains Distribution Panel in the room. Apply an appropriate LOTO padlock and label. Wait 10 minutes for the components within the Generator to discharge. 2. Remove the four Generator side panels (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513) to reveal the capacitor box. 3. Switch off the electrical power supply, on the rotary switch in the Generator cabinet (position 0). Page no. 1553 JC-DR-A-403.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A403 - Capacitor Box 4. Using a voltmeter (rating 1000 V DC), check that there is no residual voltage between screws S1 and S2 before proceeding. RC1 RC2 S10 S1 S2 S3 (C8+/C7–) S8 WARNING Residual voltage stored in the resonant capacitors can be dangerous. Ensure that the resonant capacitors are fully discharged before you handle them. 5. Remove screws S1 and S2 (10 mm open-ended wrench), and remove the two resonant capacitors, RC1 and RC2, together with their upper plate. 6. Remove screw S3 (8 mm open-ended wrench) that connects the C8+/C7– cable to the capacitor box. 7. Remove the screws S4, S5, and S6 (8 mm open-ended wrench) that connect the C1+ cables, C1–/C2+ cable and C2– cables to the capacitor box. S9 S6 (C2–) S4 (C1+) S5 (C1–/C2+) S7 Chapter 9 Page no. 1554 JC-DR-A-403.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A403 - Capacitor Box 8. Remove screws S7 and S8, followed by screws S9 and S10 mounting the capacitor box on the "Inverter" panel (4 mm allen wrench). 9. Remove the capacitor box. 6-2 Installation of Filtering Capacitors 1. Place the new capacitor box into position. Ensure that the holes on the side of the capacitor box line up with the threads on the inverter panel. 2. Attach screws S7 and S8, followed by screws S9 and S10 to mount the capacitor box on the "Inverter" panel (4 mm allen wrench). S9 S6 (C2–) S4 (C1+) S5 (C1–/C2+) S7 3. Connect the cables to the new capacitor box using the screws S4, S5, and S6 (8 mm open-ended wrench) as follows: • S4 connects the black and brown cables labeled C1+ • S5 connects the brown cable labeled C1–/C2+ • S6 connects the black and brown cables labeled C2– Page no. 1555 JC-DR-A-403.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A403 - Capacitor Box 4. Connect the C8+/C7– cable to the new capacitor box with screw S3 (8 mm open-ended wrench). RC1 RC2 S10 S1 S2 S3 (C8+/C7–) S8 5. Attach the two resonant capacitors, RC1 and RC2, together with their upper plate to the new capacitor box using screws S1 and S2 (10 mm open-ended wrench). 6. Switch on the electrical power supply, both from the Mains Distribution Panel in the room and on the rotary switch in the Generator cabinet (position I). Chapter 9 Page no. 1556 JC-DR-A-403.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A403 - Capacitor Box ILLUSTRATION 1 - CAPACITOR BOX TOP VIEW (WITHOUT RESONANT CAPACITORS) S4 S1 C7+ C7 C5 C3 C1+ C1 S5 C1-/C2+ S3 C8+/C7C8 C6 C2- C4 C2 S6 S2 C8- ILLUSTRATION 2 - CAPACITOR BOX SIDE VIEW RESONANT CAPACITORS RC1 RC2 S3 S9, S10 S1 S2 CAPACITOR BOX S7, S8 7 COMPLETION None Page no. 1557 JC-DR-A-403.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A403 - Capacitor Box This page is blank. Chapter 9 Page no. 1558 JC-DR-A-403.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A404 - HV Unit Job Card D/R A404 - HV Unit 1 • • SUPPLIES HV unit, equipped kV/mA HV grease 2 • Chapter 9 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 90 minutes 4 SAFETY PRECAUTIONS Steps in this Job Card tell you when to take appropriate action to avoid electric shock. 5 PREREQUISITES None 6 PROCEDURE CAUTION The HT block and kV/mA board assembly is factory calibrated. do not attempt to adjust potentiometer P1 (HT probe frequency compensation). 6-1 Removal and the HV Unit 1. Switch off the electrical power supply from the Mains Distribution Panel in the room. Apply an appropriate LOTO padlock and label. Wait 10 minutes for the components within the Generator to discharge. 2. Remove the four Generator side panels (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513) to reveal the HV Unit. 3. Switch off the electrical power supply on the rotary switch in the Generator cabinet (position 0). Page no. 1559 JC-DR-A-404.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A404 - HV Unit 4. Using a voltmeter (rating 1000 V DC), check that there is no residual voltage between screws S1 and S2 before proceeding. RC1 RC2 S1 S2 WARNING Residual voltage stored in the resonant capacitors can be dangerous. Ensure that the resonant capacitors are fully discharged before you handle the HV Unit. 3 5 4 2 7 6 1 5. On the HT block, disconnect the following, in the sequence listed: - HT connector (1) - heating/bias connector GKB (2) - green ground connection (3) (8 mm open-ended wrench) - white and black ground connections (two wires) (4) (8 mm open-ended wrench) - inverter GKA/1 and GKA/2 (5) (8 mm open-ended wrench) - HT probe cable: GKC (6) Chapter 9 Page no. 1560 JC-DR-A-404.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A404 - HV Unit 6. On the kV/mA board located on the side of the HV unit, disconnect the cables on XJ2, XJ3, and XJ1. XJ2 XJ3 XJ1 7. Tighten the air-bleed screw (7). 8. Remove the three allen screws (8) (5 mm allen wrench) that secure the HV unit to the Generator framework. The three allen screws are located on the three accessible sides of the HV unit. 7 8 9. Carefully remove the faulty HV unit from the Generator. 6-2 Installation of the HV Unit 1. Carefully place the new HV unit into the Generator framework. Ensure that the holes for the three allen screws line up with the three threads on the Generator framework. 2. Attach the three allen screws (1) (5 mm allen wrench) to secure the HV unit to the Generator frame- Page no. 1561 JC-DR-A-404.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A404 - HV Unit work. The three allen screws are located on the three accessible sides of the HV unit. 1 CAUTION Pay particular attention to ensure that you do not damage the kV/mA board when tightening the allen screw which is in close proximity to the kV/mA board. 3. On the kV/mA board located on the side of the HV unit, make the following cable connections: • Gray ribbon cable to the XJ1 connector, ensuring that the red part of the ribbon cable is at the bottom. Be careful when inserting the cable into the XJ1 connector and apply equal pressure to ensure that you do not bend the connector pins • Two black cables into the black connector to the XJ2 connector. • The black probe cable with the BNC connector to the XJ3 connector. XJ2 XJ3 XJ1 Note : XJ4 connector is empty Chapter 9 Page no. 1562 JC-DR-A-404.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A404 - HV Unit 4. On the HT block, disconnect the following, in the sequence listed: - HT probe cable: GKC (2) - inverter GKA/1 (3) (8 mm open-ended wrench) - inverter GKA/2 (4) (8 mm open-ended wrench) - white and black ground connections (two wires) (5) (8 mm open-ended wrench) - green ground connection (6) (8 mm open-ended wrench) - heating/bias connector GKB (7) - HT connector (8) 6 3 4 5 7 9 2 8 5. Grease the HT end-piece if necessary. 6. Slacken the air-bleed screw (9). 7. Switch on the electrical power supply, both from the Mains Distribution Panel in the room and on the rotary switch in the Generator cabinet (position I). 8. Switch on the Senographe system electrical power (i.e. Generator, Gantry, and Control Station). 9. Wait until the Gantry boot is complete, and check that no error has been reported. If the HV unit is operating correctly, the LED states on the kV/mA board are as follows: • all three of the green LEDs (i.e. DS1, DS2, and DS3) are ON 10. Reinstall the Generator covers (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513). Page no. 1563 JC-DR-A-404.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A404 - HV Unit 7 COMPLETION Carry out the following calibrations: Calibrations - Checks Job Card Acquisition Image Chain Heating Current Calibration Job Card CAL A001 - Heater Current Scale Factor on page 1649 Bias Calibration Job Card CAL A003 - X-Ray Tube Focal Bias Voltage Scale Factor on page 1655 Tube mA Measurement Job Card CAL A009 - X-Ray Tube mA Measurement on page 1663 kV Scale Factor Job Card CAL A011 - Calibration of kV Scale Factor on page 1667 mAs X-ray Calibration Job Card CAL A012 - X-Ray Tube Heater Current on page 1673 Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 If IQ Tests not OK, repeat all calibrations from Bad Pixel. Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Use the same dosimeter as that used for CAL A046 AOP: Automatic Optimization of Parameters AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations from AOP Calibration. Chapter 9 Page no. 1564 JC-DR-A-404.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A405 - HV Cable Job Card D/R A405 - HV Cable 1 Chapter 9 SUPPLIES HV Cable HV grease 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 2 Field Engineers Time: 5 hours 4 SAFETY PRECAUTIONS The procedures in this Job Card produce X-rays. Ensure that you take appropriate precautions when operating with X-rays (for example, stay behind the radiation screen during an X-ray exposure). 5 PREREQUISITES None 6 PROCEDURE 6-1 Removal and re-installation of the HV Cable 1. Switch off the electrical power supply from the Mains Distribution Panel in the room. Apply an appropriate LOTO padlock and label. Wait 10 minutes for the components within the Generator to discharge. 2. Remove the Generator covers (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513). 3. Remove the Gantry covers (see Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). 4. Disconnect the cable from the Generator HV tank and from the Tube connector J2. 5. Remove the cable. ! Notice: When it is necessary to cut cable ties which secure the cable to mechanical components or to other cables, take care to note or mark the exact position of the cable. This is required so that replacement of the cable can be made in the same manner. Refer to section 6-2 for specific cable positioning information. 6. Install the replacement cable; position it as described below. Use HV grease on the HT connection as required. Page no. 1565 JC-DR-A-405.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A405 - HV Cable 6-2 Cable Positioning • After the cable has been changed or otherwise disturbed, ensure that you follow the positioning instructions given in the following sections. • To aid correct positioning, the cable carries five reference marks. They are referred to as M1 through M5, and are positioned on the cable at the following distances from the tube end of the cable: - M1; 635 mm - M2; 1565 mm - M3; 1840 mm - M4; 3515 mm - M5; 5300 mm • When changing the HV cable install new cable ties in the same positions where the original cable ties were. 6-2-1 Reference Mark M1 ! Notice: The position of reference mark M1 is critical. Mark M1 must be positioned at the point where the cable from the tube enters the top of the arm metal tube. It must be level with the surface of the tube opening. The tolerance is ±10 mm. 6-2-2 Reference mark M1 Reference Mark M2. Reference mark M2 Metal clamp Chapter 9 Mark M2 must be positioned at the edge of the metal clamp which secures the cable as it exits the bottom of the arm metal tube. Page no. 1566 JC-DR-A-405.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A405 - HV Cable 6-2-3 Reference Mark M3. Mark M3 must be positioned at the level of the bottom surface of the metal clamp, which secures the cable harness as it exits the bottom of the arm. 6-2-4 Reference mark M3 Reference Mark M4. Mark M4 must be positioned at the external surface of the column. Reference mark M4 6-2-5 Reference Mark M5. Mark M5 must be positioned at the point where the cable leaves the cable sheath at the input to the Generator cabinet. 7 Reference mark M5 COMPLETION Check for correct operation of X-ray exposures. Page no. 1567 JC-DR-A-405.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A405 - HV Cable This page is blank. Chapter 9 Page no. 1568 JC-DR-A-405.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A406 - Generator Command Board 400-PL1 Job Card D/R A406 - Generator Command Board 400-PL1 1 • SUPPLIES Generator Command Board 400-PL1 2 • Chapter 9 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 90 minutes 4 SAFETY PRECAUTIONS Steps in this Job Card tell you when to take appropriate action to avoid electric shock 5 PREREQUISITES None 6 PROCEDURE 6-1 Removal of the Generator Command Board 400-PL1 1. Switch off the electrical power supply from the Mains Distribution Panel in the room. Apply an appropriate LOTO padlock and label. Wait 10 minutes for the components within the Generator to discharge. 2. Remove the four Generator side panels (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513) to reveal the Generator Command board 400-PL1. 3. Switch off the electrical power supply on the rotary switch in the Generator cabinet (position 0). 4. Using a voltmeter (rating 1000 V DC), check that there is no residual voltage between screws S1 and Page no. 1569 JC-DR-A-406.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A406 - Generator Command Board 400-PL1 S2 before proceeding. RC1 RC2 S1 S2 WARNING Residual voltage stored in the resonant capacitors can be dangerous. Ensure that the resonant capacitors are fully discharged before you handle the Generator Command board. 1 1 Chapter 9 Page no. 1570 JC-DR-A-406.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A406 - Generator Command Board 400-PL1 5. The Generator Command board is located on the top left of the Generator. Disconnect all the cables from the Generator Command board and make a mental note where they connect to. Ensure that you do not move them too much so it is easier to re-connect them later on. ! Notice: Disconnect with caution to avoid damage to the connectors and cables. 6. Remove the eight screws (1) that secure the Generator Command board (4 mm allen wrench) to the Generator chassis, and carefully remove the defective Generator Command board. 7. Make a note of the defective Generator Command board current jumper settings. There are two sets of jumpers JP1/JP2 below the XJ8 connector, and JP3/JP4 above the XJ8 connector. These jumpers determine the room lamps and door configuration. 8. Put the defective Generator Command board in an anti-static bag. 6-2 Installation of the Generator Command Board 400-PL1 1. Carefully place the new Generator Command board on the Generator chassis. Ensure that the holes for the eight allen screws line up with the eight threads on the Generator chassis. 1 1 2. Attach the eight allen screws (1) (4 mm allen wrench) to secure the Generator Command board to the Generator chassis. 3. Connect all the cables to the new Generator Command board as summarized in the diagram and table below. Page no. 1571 JC-DR-A-406.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A406 - Generator Command Board 400-PL1 XJ6 XJ2 XJ4 XJ3 XJ9 XJ7 XJ10 XJ5 XJ1 XJ8 XJ13 Chapter 9 Page no. 1572 JC-DR-A-406.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A406 - Generator Command Board 400-PL1 Connector Label Description of cable (usually identified by code on a white label) Cable color XJ1 400 PL1 XJ1 (red line on right of ribbon connector) Gray XJ2 XJ2 Black XJ3 400 PL1 XJ3 Black XJ4 400 PL1 XJ4 5 Black 1 White XJ5 C801418 XP1 XP2 (ribbon cable to kVmA board, red line on right of ribbon connector) Gray XJ6 400 PL1 XJ6 (red line on right of ribbon connector) Gray XJ7 400 PL1 XJ7 (red line on top of ribbon connector) Gray XJ8 The X-ray Console cable White XJ9 45440115 Black XJ10 400 PL2 XJ2, 45440116, 400 PL1 X10 (red line on top of ribbon connector) Gray XJ12 Empty N/A XJ13 400 PL1 XJ13 (red line on left of ribbon connector) Gray 4. Ensure that the JP3 and JP4 (2) jumpers and JP1 and JP2 (3) above and below the XJ8 connector on the Generator Command board are set the same as the defective board that you have just replaced.These jumpers determine the room lamps and door configuration, which can vary one each customer site. 2 3 5. If the customer wants a different lamp and door configuration to before, set jumpers JP1 and JP2 as required according to the table below. Place unused jumpers in the parking positions JP3 and JP4. Note: If there is no door switch, jumpers JP1 and JP2 must both be present (case 4 in the table). Page no. 1573 JC-DR-A-406.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A406 - Generator Command Board 400-PL1 TABLE 1 - JP1 AND JP2 JUMPER SETTINGS JP1 (PREP) JP2 (RADIOGRAPHY) Door closed Door opened 1 0 0 PREP and RADIOGRAPHY enabled PREP and RADIOGRAPHY disabled 2 0 1 PREP and RADIOGRAPHY enabled PREP and RADIOGRAPHY disabled. NOTE: if the door opens during an exposure, the exposure is not aborted and completes normally) 3 1 0 PREP and RADIOGRAPHY enabled PREP enabled RADIOGRAPHY disabled 4 1 1 PREP and RADIOGRAPHY enabled PREP and RADIOGRAPHY enabled 0 = No jumper 1 = Jumper present 6. Ensure that all the Test Point (TP) connectors (labeled TP1, ... etc.) on the Generator Command board are open. 7. Switch on the electrical power supply, both from the Mains Distribution Panel in the room and on the rotary switch in the Generator cabinet (position I). 8. Switch on the Senographe system electrical power (i.e. Generator, Gantry, and Control Station). 9. Wait until the Gantry boot is complete, and check that no error has been reported. If the Generator Command board is operating correctly, the LED states on the Generator Command board are as follows: • green DS1 LED is OFF • red DS8 LED is OFF • yellow DS2 LED is OFF • green DS9 LED ON • green DS3 LED is OFF • yellow DS10 LED is OFF • red DS4 LED is ON • green DS11 LED ON • yellow DS5 LED is OFF • red DS12 LED is OFF • green DS6 LED is ON • red DS13 LED is OFF • yellow DS7 LED ON 10. Reinstall the Generator covers (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513). Chapter 9 Page no. 1574 JC-DR-A-406.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A406 - Generator Command Board 400-PL1 7 COMPLETION Carry out the following calibrations: Calibrations - Checks Job Card Bias Calibration Job Card CAL A003 - X-Ray Tube Focal Bias Voltage Scale Factor on page 1655 Heating Current Calibration Job Card CAL A001 - Heater Current Scale Factor on page 1649 kV Scale Factor Job Card CAL A011 - Calibration of kV Scale Factor on page 1667 mAs X-ray Calibration Job Card CAL A012 - X-Ray Tube Heater Current on page 1673 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 Page no. 1575 JC-DR-A-406.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A406 - Generator Command Board 400-PL1 This page is blank. Chapter 9 Page no. 1576 JC-DR-A-406.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A407 - Generator Interface Board 400-PL2 Job Card D/R A407 - Generator Interface Board 400-PL2 1 • SUPPLIES Generator Interface Board 400-PL2 2 • Chapter 9 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 90 minutes 4 SAFETY PRECAUTIONS Steps in this Job Card tell you when to take appropriate action to avoid electric shock. 5 PREREQUISITES None 6 PROCEDURE 6-1 Removal of the Generator Interface Board 400-PL2 1. Switch off the electrical power supply from the Mains Distribution Panel in the room. Apply an appropriate LOTO padlock and label. Wait 10 minutes for the components within the Generator to discharge. 2. Remove the four Generator side panels (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513) to reveal the Generator Interface board 400-PL2. 3. Switch off the electrical power supply on the rotary switch in the Generator cabinet (position 0). 4. Using a voltmeter (rating 1000 V DC), check that there is no residual voltage between screws S1 and Page no. 1577 JC-DR-A-407.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A407 - Generator Interface Board 400-PL2 S2 before proceeding. RC1 RC2 S1 S2 WARNING Residual voltage stored in the resonant capacitors can be dangerous. Ensure that the resonant capacitors are fully discharged before you handle the Generator Interface board. 1 5. The Generator Interface board is located on the middle right of the Generator. Disconnect all the cables and optical fibers from the Generator Interface board and make a mental note where they connect to. Ensure that you do not move them too much so it is easier to re-connect them later on. ! Notice: Disconnect with caution to avoid damage to the connectors and cables. 6. Remove the five screws (1) that secure the Generator Interface board (4 mm allen wrench) to the Generator chassis. Carefully remove the defective Generator Interface board by pulling it downwards away from the Generator CPU board. Chapter 9 Page no. 1578 JC-DR-A-407.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A407 - Generator Interface Board 400-PL2 7. Put the defective Generator Interface board in an anti-static bag. 6-2 Installation of the Generator Interface Board 400-PL2 1. Carefully place the new Generator Interface board on the Generator chassis by inserting it up into the connectors of the Generator CPU board. Ensure that the holes for the five allen screws line up with the five threads on the Generator chassis. 1 2. Attach the five allen screws (1) (4 mm allen wrench) to secure the Generator Interface board to the Generator chassis. 3. Connect all the cables to the new Generator Interface board as summarized in the diagram and table below. Page no. 1579 JC-DR-A-407.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A407 - Generator Interface Board 400-PL2 XJ1 XJ4 XJ2 XJ6 XJ7 XJ8 XJ9 XJ11 XJ10 Chapter 9 Connector Label Description of cable (usually identified by code on a white label) Cable color XJ1 45440115 Black XJ2 400 PL2 XJ2, 45440116, 400 PL1 X10 (red line on top of ribbon connector) Gray XJ4 XJ4 GENE 400 PL2 Gray XJ6 400 PL2 XJ6 (optical fiber) Black XJ7 400 PL2 XJ7 (optical fiber) Black XJ8 Empty (optical fiber blank cover) N/A XJ9 400 PL2 XJ9 (optical fiber) Black XJ10 XJ4 GENE 400 PL2 Gray XJ11 XJ11 - 400PL2 GENE. INTERF. Gray Page no. 1580 JC-DR-A-407.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A407 - Generator Interface Board 400-PL2 4. Ensure that all the Test Point (PT) connectors (labeled PT1, ... etc.) on the Generator Interface board are open. 5. Ensure that all the Test Point (TP) connectors (labeled PT1 to TP53) located to the right of the XJ2 connector on the Generator Interface board are open. 6. Switch on the electrical power supply, both from the Mains Distribution Panel in the room and on the rotary switch in the Generator cabinet (position I). 7. Switch on the Senographe system electrical power (i.e. Generator, Gantry, and Control Station). 8. Wait until the Gantry boot is complete, and check that no error has been reported. If the Generator Interface board is operating correctly, the LED states on the Generator Interface board are as follows: • yellow DS1 LED is ON • yellow DS2 LED is ON • yellow DS3 LED is ON • yellow DS4 LED is ON • yellow DS5 LED is ON • yellow DS6 LED is ON • yellow DS7 LED is ON • yellow DS8 LED is ON • yellow DS9 LED is ON • green DS10 LED is OFF • green DS11 LED is OFF • green DS12 LED is ON • green DS13 LED is ON • green DS14 LED is ON • red DS15 LED is OFF 9. Reinstall the Generator covers (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513). Page no. 1581 JC-DR-A-407.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A407 - Generator Interface Board 400-PL2 7 COMPLETION Carry out the following calibrations after you have changed the Generator Interface board: Calibrations - Checks Job Card Bias Calibration Job Card CAL A003 - X-Ray Tube Focal Bias Voltage Scale Factor on page 1655 Heating Current Calibration Job Card CAL A001 - Heater Current Scale Factor on page 1649 kV Scale Factor Job Card CAL A011 - Calibration of kV Scale Factor on page 1667 mAs X-ray Calibration Job Card CAL A012 - X-Ray Tube Heater Current on page 1673 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 Chapter 9 Page no. 1582 JC-DR-A-407.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A408 - Generator Supply Command Board 200-PL2 Job Card D/R A408 - Generator Supply Command Board 200-PL2 Chapter 9 1 • SUPPLIES Generator Supply Command Board 200-PL2 2 • TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS Steps in this Job Card tell you when to take appropriate action to avoid electric shock. 5 PREREQUISITES None 6 PROCEDURE 6-1 Removal of the Generator Supply Command Board 200-PL2 1. Switch off the electrical power supply from the Mains Distribution Panel in the room. Apply an appropriate LOTO padlock and label. Wait 10 minutes for the components within the Generator to discharge. 2. Remove the four Generator side panels (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513) to reveal the Generator Supply Command board 200-PL2. 3. Switch off the electrical power supply on the rotary switch in the Generator cabinet (position 0). 4. Using a voltmeter (rating 1000 V DC), check that there is no residual voltage between screws S1 and Page no. 1583 JC-DR-A-408.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A408 - Generator Supply Command Board 200-PL2 S2 before proceeding. RC1 RC2 S1 S2 WARNING Residual voltage stored in the resonant capacitors can be dangerous. Ensure that the resonant capacitors are fully discharged before you handle the Generator Supply Command board. 5. The XJ6 and XJ7 connectors may still have a residual voltage of 35V DC from the C2 capacitor located behind the Generator Supply Command board. Using a voltmeter (rating 1000 V DC), check that there is no residual voltage (35V DC) between the XJ6 and XJ7 connectors. XJ6 XJ7 C1P M1P Chapter 9 Page no. 1584 JC-DR-A-408.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A408 - Generator Supply Command Board 200-PL2 6. The C1P and M1P connectors may still have a residual voltage of 250V DC from the C1 capacitor located behind the Generator Supply Command board. Using a voltmeter (rating 1000 V DC), check that there is no residual voltage (250V DC) between the C1P and M1P connectors. C2 C1 XJ6 XJ7 C1P M1P WARNING Residual voltage stored in the C1 and C2 capacitors (located behind the Generator Command Supply board can be dangerous. Ensure that the capacitors are fully discharged before you handle the Generator Supply Command board. Page no. 1585 JC-DR-A-408.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A408 - Generator Supply Command Board 200-PL2 7. Disconnect all the cables from the Generator Supply Command board and make a mental note where they connect to. Ensure that you do not move them too much so it is easier to re-connect them later on. ! Notice: Disconnect with caution to avoid damage to the connectors and cables. 8. Remove the four nuts (1) (8 mm open ended wrench) that secure the Generator Supply Command board to the Generator chassis. Carefully remove the defective Generator Supply Command board. The top left nut also attaches a black cable to the Generator Supply Command board – do not move this cable too far as you will re-connect it when you install the new Generator Supply Command board. 1 9. Put the defective Generator Supply Command board in an anti-static bag. Chapter 9 Page no. 1586 JC-DR-A-408.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A408 - Generator Supply Command Board 200-PL2 6-2 Installation of the Generator Supply Command board 200-PL2 1. Carefully place the new Generator Supply Command board on the Generator chassis four threads. 1 2 3 2. Attach the black cable (1) that you originally removed to the top left thread, and secure it by attaching a nut (2) to the top left thread (8 mm open-ended wrench). 3. Attach the other three nuts (3) (8 mm open-ended wrench) to secure the rest of the Generator Supply Command board to the Generator chassis. 4. Connect all the cables to the new Generator Supply Command board as summarized in the diagram and table below. Page no. 1587 JC-DR-A-408.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A408 - Generator Supply Command Board 200-PL2 XJ11 XJ4 F3-2 XJ9 XJ8 XJ1 XJ3 D27-AK TP10 XJ6 XJ10 XJ7 C1P XJ2 XJ5 M1P Connector Label Tool Description of cable (usually identified by code on a white label) Cable color XJ1 N/A 400 PL1 XJ1 (red line at bottom of ribbon connector) Gray XJ11 N/A 200 PL2 XJ11 (red line at left of ribbon connector) Gray XJ2 N/A 200 PL2/XJ2 Gray XJ3 N/A 200 PL2/XJ2 (cable labeled "T" on top) Black XJ4 N/A 200 PL2 XJ4 Gray XJ5 N/A XJ5 Black XJ8 N/A Two brown cables in to black connector Brown TP10 N/A Black cable with red end plastic, coming from to left conduit Black XJ10 Small screwdriver 200 PL2/XJ10 Black C1P Small screwdriver C1P Brown M1P Small screwdriver M1P Brown XJ6 8 mm open ended wrench XJ6 Brown Chapter 9 Page no. 1588 JC-DR-A-408.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A408 - Generator Supply Command Board 200-PL2 Connector Label Tool Description of cable (usually identified by code on a white label) Cable color XJ7 8 mm open ended wrench XJ7 (on two cables) Brown Yellow/green XJ9 8 mm open ended wrench 200 PL2/XJ9 Black F3-2 13 mm open ended wrench 200 PL2/F3-2 Black D27-AK Cross-head screwdriver 200 PL2/D27-AK Black 5. Except for the TP10 connector which you connected earlier, ensure that all the Test Point (TP) connectors (labeled TP1, ... etc.) on the Generator Supply Command board are open. 6. Switch on the electrical power supply, both from the Mains Distribution Panel in the room and on the rotary switch in the Generator cabinet (position I). 7. Switch on the Senographe system electrical power (i.e. Generator, Gantry, and Control Station). 8. Wait until the Gantry boot is complete, and check that no error has been reported. If the Generator Command board is operating correctly, the LED states on the Generator Command board are as follows: • green DE1 LED is ON • red DE2 LED is OFF • red DE3 LED is OFF • clear N1 LED is ON 9. Reinstall the Generator covers (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513). 7 COMPLETION None. Page no. 1589 JC-DR-A-408.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A408 - Generator Supply Command Board 200-PL2 This page is blank. Chapter 9 Page no. 1590 JC-DR-A-408.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A409 - Relay Board 200-PL4 Job Card D/R A409 - Relay Board 200-PL4 1 SUPPLIES • Relay Board 200-PL4 2 • Chapter 9 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 20 minutes 4 SAFETY PRECAUTIONS Steps in this Job Card tell you when to take appropriate action to avoid electric shock. 5 PREREQUISITES None 6 PROCEDURE 6-1 Removal of the Generator Relay Board 200-PL4 1. Switch off the electrical power supply from the Mains Distribution Panel in the room. Apply an appropriate LOTO padlock and label. Wait 10 minutes for the components within the Generator to discharge. WARNING It is important that you switch off the external power supply on the Mains Distribution Panel. This is because you will be working in close proximity to where the external voltage arrives into the Generator. 2. Remove the four Generator side panels (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513) to reveal the Generator Relay board 200-PL4. 3. Switch off the electrical power supply on the rotary switch in the Generator cabinet (position 0). Page no. 1591 JC-DR-A-409.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A409 - Relay Board 200-PL4 4. Using a voltmeter (rating 1000 V DC), check that there is no residual voltage between screws S1 and S2 before proceeding. RC1 RC2 S1 S2 WARNING Residual voltage stored in the resonant capacitors can be dangerous. Ensure that the resonant capacitors are fully discharged before you handle the Relay board. 5. Switch off the external power supply that runs between the room lamps and the cables (1) that are connected to the Generator Relay board. WARNING The lamp cables contain a live voltage from an external source. It is important that you switch off the external power supply to the lamp cables because you will be handling them in order to remove Generator Relay board. 2 3 ! 3 Ensure that the external power from the room Mains Distribution Panel has been switched off before you start to handle the Generator Relay board. 1 6. The Generator Relay board is located on the side of the Generator, behind the Generator Interface board. Make a note of the defective Generator Relay board current lamp and door cable configuration. The configuration determines how the room lamps and door operate with the Senographe system for that particular customer. Disconnect the room and door cables (1) from the Generator Relay Chapter 9 Page no. 1592 JC-DR-A-409.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A409 - Relay Board 200-PL4 board. 7. Carefully disconnect the data cable (2) from the Generator Relay board. Ensure that you do not move it too much so it is easier to re-connect it later on. ! Notice: Disconnect with caution to avoid damage to the connectors and cables. 8. Remove the four screws (3) that secure the Generator Relay board (4 mm allen wrench) to the Generator chassis, and carefully remove the defective Generator Relay board. 9. Put the defective Generator Relay board in an anti-static bag. 6-2 Installation of the Generator Relay Board 200-PL4 1. Carefully place the new Generator Relay board on the Generator chassis. Ensure that the holes for the four allen screws line up with the four threads on the Generator chassis. 2 1 1 3 2. Attach the four allen screws (1) (4 mm allen wrench) to secure the Generator Relay board to the Generator chassis. 3. Carefully re-connect the data cable (2) to the Generator Relay board. The red line of the ribbon cable must be on the right-hand side of the connector. 4. Reconnect the lamp and door cables (3) exactly how they were connected before. 5. Re-establish the external power supply to the room lamps. 6. Switch on the electrical power supply, both from the Mains Distribution Panel in the room and on the Page no. 1593 JC-DR-A-409.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A409 - Relay Board 200-PL4 rotary switch in the Generator cabinet (position I). 7. Switch on the Senographe system electrical power (i.e. Generator, Gantry, and Control Station). 8. Wait until the Gantry boot is complete, and check that no error has been reported. 9. Reinstall the Generator covers (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513). 7 COMPLETION None. Chapter 9 Page no. 1594 JC-DR-A-409.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A410 - Inverter Board 300-PL1 Job Card D/R A410 - Inverter Board 300-PL1 1 • Chapter 9 SUPPLIES Inverter Board 300-PL1 2 • TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 20 minutes 4 SAFETY PRECAUTIONS Steps in this Job Card tell you when to take appropriate action to avoid electric shock. 5 PREREQUISITES None 6 PROCEDURE 6-1 Removal of the Inverter Board 300-PL1 1. Switch off the electrical power supply from the Mains Distribution Panel in the room. Apply an appropriate LOTO padlock and label. Wait 10 minutes for the components within the Generator to discharge. WARNING It is important that you switch off the external power supply on the Mains Distribution Panel. This is because you will be working in close proximity to where the external voltage arrives into the Generator. 2. Remove the four Generator side panels (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513) to reveal the Inverter board 300-PL1. 3. Switch off the electrical power supply on the rotary switch in the Generator cabinet (position 0). Page no. 1595 JC-DR-A-410.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A410 - Inverter Board 300-PL1 4. Using a voltmeter (rating 1000 V DC), check that there is no residual voltage between screws S1 and S2 before proceeding. RC1 RC2 S1 S2 WARNING Residual voltage stored in the resonant capacitors can be dangerous. Ensure that the resonant capacitors are fully discharged before you handle the Inverter board. 5. Remove all of the cables from the Inverter board (10 mm open ended wrench and small screwdriver). Ensure that you do not move them too much so they are easier to re-connect later on. 2 1 6. Remove the six bolts (1) and the one nut (2) (7 mm open ended wrench) which attach the Inverter board to the Generator chassis. 7. Remove the faulty Inverter board from the Generator chassis. Pay attention since some of the cables pass through holes in the Inverter board. Put the defective Inverter board in an anti-static bag. Chapter 9 Page no. 1596 JC-DR-A-410.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A410 - Inverter Board 300-PL1 6-2 Installation of the Inverter Board 300-PL1 1. Carefully place the new Inverter board on the Generator chassis. Ensure that the one thread passes thorough the Inverter board top middle hole, and ensure that the holes for the six bolts line up with the four threads on the Generator chassis. 4 1 2 5 3 2. When placing the new Inverter board on the Generator chassis ensure that you the thread the three sets of brown cables through the holes in the Inverter board (1, 2, 3). 3. Attach the bolt (4) (7 mm open ended wrench) to the thread. 4. Attach the six bolts (5) (7 mm allen wrench) to secure the rest of the Inverter board to the Generator chassis. 5. Connect all the cables to the new Inverter board as summarized in the diagram and table below. Connector Label Tool Description of cable (usually identified by code on a white label) Cable color XJ1 N/A 300 PL1 XJ1 2110262 (red line at top of ribbon connector) Gray X1 10 mm open ended wrench X1 Black X2 N/A Empty N/A X3 10 mm open ended wrench X3 Brown X4 10 mm open ended wrench X4 Brown X5 10 mm open ended wrench X5 Black X6 10 mm open ended wrench X6 Brown X7 10 mm open ended wrench X7 Brown X8 10 mm open ended wrench Two cables, one from below and one from behind: X8 Brown X9 10 mm open ended wrench X9 Brown Page no. 1597 JC-DR-A-410.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A410 - Inverter Board 300-PL1 Connector Label Tool Description of cable (usually identified by code on a white label) Cable color X10 10 mm open ended wrench X10 Brown X11 Small screwdriver X11/X12 Brown X12 Small screwdriver X11/X12 Brown X13 Small screwdriver 2117977: G1 (from lower hole) Brown X14 Small screwdriver 2117977: K1 (from lower hole) Brown X15 Small screwdriver 2117977: G1 (from upper hole) Brown X16 Small screwdriver 2117977: K1 (from upper hole) Brown X14 X13 X15 X16 XJ1 X7 X11 X10 X12 X1 X5 X2 X4 X3 X9 X6 X8 6. Switch on the electrical power supply, both from the Mains Distribution Panel in the room and on the Chapter 9 Page no. 1598 JC-DR-A-410.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A410 - Inverter Board 300-PL1 rotary switch in the Generator cabinet (position I). 7. Switch on the Senographe system electrical power (i.e. Generator, Gantry, and Control Station). 8. Wait until the Gantry boot is complete, and check that no error has been reported. If the Inverter board is operating correctly, the L1 LED is ON. 9. Reinstall the Generator covers (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513). 7 COMPLETION None. Page no. 1599 JC-DR-A-410.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A410 - Inverter Board 300-PL1 This page is blank. Chapter 9 Page no. 1600 JC-DR-A-410.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A411 - Mains Distribution Board 200-PL1 Job Card D/R A411 - Mains Distribution Board 200-PL1 1 • Chapter 9 SUPPLIES Mains Distibution Board 200-PL1 2 • TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 20 minutes 4 SAFETY PRECAUTIONS Steps in this Job Card tell you when to take appropriate action to avoid electric shock. 5 PREREQUISITES None 6 PROCEDURE 6-1 Removal of the Mains Distribution Board 200-PL1 1. Switch off the electrical power supply from the Mains Distribution Panel in the room. Apply an appropriate LOTO padlock and label. Wait 10 minutes for the components within the Generator to discharge. WARNING It is important that you switch off the external power supply on the Mains Distribution Panel. This is because you will be working in close proximity to where the external voltage arrives into the Generator. 2. Remove the four Generator side panels (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513) to reveal the Mains Distribution board 200-PL1. 3. Switch off the electrical power supply on the rotary switch in the Generator cabinet (position 0). Page no. 1601 JC-DR-A-411.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A411 - Mains Distribution Board 200-PL1 4. Using a voltmeter (rating 1000 V DC), check that there is no residual voltage between screws S1 and S2 before proceeding. RC1 RC2 S1 S2 WARNING Residual voltage stored in the resonant capacitors can be dangerous. Ensure that the resonant capacitors are fully discharged before you handle the Mains Distribution board. 5. The XJ8 and XJ9 connectors may still have a residual voltage of 600V DC from the C1, C2, C5, C6, C7, and C8 capacitors located behind the Mains Distribution board. Using a voltmeter (rating 1000 V DC), check that there is no residual voltage (600V DC) between the XJ8 and XJ9 connectors connectors. XJ8 Chapter 9 XJ9 Page no. 1602 JC-DR-A-411.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A411 - Mains Distribution Board 200-PL1 C6 C8 C2 C1 C7 C5 XJ8 XJ9 WARNING Residual voltage stored in the C1, C2, C5, C6, C7, and C8 capacitors (located behind the Mains Distribution board can be dangerous. Ensure that the capacitors are fully discharged before you handle the Mains Distribution board. Page no. 1603 JC-DR-A-411.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A411 - Mains Distribution Board 200-PL1 6. Remove all of the cables from the Mains Distribution board (8 mm open ended wrench). Ensure that you do not move them too much so they are to re-connect later on. 1 7. Remove the four bolts (1) (7 mm open ended wrench) which attach the Mains Distribution board to the Generator chassis. 8. Remove the faulty Mains Distribution board from the Generator chassis. 9. Put the defective Mains Distribution board in an anti-static bag. Chapter 9 Page no. 1604 JC-DR-A-411.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A411 - Mains Distribution Board 200-PL1 6-2 Installation of the Mains Distribution Board 200-PL1 1. Carefully place the new Mains Distribution board on the Generator chassis. Ensure that the holes for the four bolts line up with the four threads on the Generator chassis. 1 2. Attach the four bolts (1) (7 mm allen wrench) to secure the Mains Distribution board to the Generator chassis. 3. Connect all the cables to the new Mains Distribution board as summarized in the diagram and table below. Connector Label Tool Description of cable (usually identified by code on a white label) Cable color XJ1 8 mm open ended wrench XJ1 Brown XJ2 8 mm open ended wrench Two cables: XJ2 Brown XJ3 8 mm open ended wrench XJ3 Brown XJ4 8 mm open ended wrench XJ4 Brown XJ6 8 mm open ended wrench XJ6 Brown XJ7 8 mm open ended wrench XJ7 Brown XJ8 8 mm open ended wrench XJ8 Brown XJ9 8 mm open ended wrench XJ9 Brown XJ10 N/A XJ10/PL1 2111145 White XJ11 N/A 200 PL1 XJ1 Gray XJ12 N/A Empty N/A XJ13 N/A Empty N/A XJ14 N/A Empty N/A TR1 - 5 8 mm open ended wrench SEL Brown TR1 - 0 8 mm open ended wrench 0V Brown Page no. 1605 JC-DR-A-411.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A411 - Mains Distribution Board 200-PL1 XJ13 XJ6 XJ7 XJ8 XJ12 XJ9 XJ4 XJ14 XJ11 TR1-5 TR1-0 XJ3 XJ2 XJ1 4. Switch on the electrical power supply, both from the Mains Distribution Panel in the room and on the Chapter 9 Page no. 1606 JC-DR-A-411.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A411 - Mains Distribution Board 200-PL1 rotary switch in the Generator cabinet (position I). 5. Switch on the Senographe system electrical power (i.e. Generator, Gantry, and Control Station). Wait until the Gantry boot is complete, and check that no error has been reported. If the Mains Distribution board is operating correctly, the LED states on the Mains Distribution board are as follows: • red DE1 LED is OFF • green DE2 LED is ON • green DE3 LED is ON • red DE4 LED is OFF • yellow DE5 LED is OFF • yellow DE6 LED is ON • red DE7 LED is OFF • clear N1 LED is ON • clear K1 LED is ON 6. Reinstall the Generator covers (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513). 7 COMPLETION None. Page no. 1607 JC-DR-A-411.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A411 - Mains Distribution Board 200-PL1 This page is blank. Chapter 9 Page no. 1608 JC-DR-A-411.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A412 - Anode Starter Board 300-PL2 Job Card D/R A412 - Anode Starter Board 300-PL2 1 • Chapter 9 SUPPLIES Anode Starter Board 300-PL2 2 • TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 20 minutes 4 SAFETY PRECAUTIONS Steps in this Job Card tell you when to take appropriate action to avoid electric shock. 5 PREREQUISITES None 6 PROCEDURE 6-1 Removal of the Anode Starter Board 300-PL2 1. Switch off the electrical power supply from the Mains Distribution Panel in the room. Apply an appropriate LOTO padlock and label. Wait 10 minutes for the components within the Generator to discharge. WARNING It is important that you switch off the external power supply on the Mains Distribution Panel. This is because you will be working in close proximity to where the external voltage arrives into the Generator. 2. Remove the four Generator side panels (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513) to reveal the Anode Starter board 300-PL2. 3. Switch off the electrical power supply on the rotary switch in the Generator cabinet (position 0). Page no. 1609 JC-DR-A-412.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A412 - Anode Starter Board 300-PL2 4. Using a voltmeter (rating 1000 V DC), check that there is no residual voltage between screws S1 and S2 before proceeding. RC1 RC2 S1 S2 WARNING Residual voltage stored in the resonant capacitors can be dangerous. Ensure that the resonant capacitors are fully discharged before you handle the Anode Starter board. 5. Remove all of the cables from the Anode Starter board. Ensure that you do not move them too much so they are easier to re-connect later on. 1 6. Remove the four bolts (1) (7 mm open ended wrench) which attach the Anode Starter board to the Generator chassis. 7. Remove the faulty Anode Starter board from the Generator chassis. Chapter 9 Page no. 1610 JC-DR-A-412.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A412 - Anode Starter Board 300-PL2 8. Put the defective Anode Starter board in an anti-static bag. 6-2 Installation of the Anode Starter Board 300-PL2 1. Carefully place the new Anode Starter board on the Generator chassis. Ensure that the holes for the four bolts line up with the four threads on the Generator chassis. XJ1 1 XJ3 XJ2 2. Attach the four bolts (1) (7 mm allen wrench) to secure the Anode Starter board to the Generator chassis. 3. Connect all the cables to the new Anode Starter board as summarized in the diagram above and table below. Connector Label Description of cable (usually identified by code on a white label) Cable color XJ1 300 PL2 XJ1 2110264 (red line of the ribbon cable on the left-hand side as you look directly at the board) Gray XJ2 Empty N/A XJ3 300 PL2 XJ3 Black 4. Switch on the electrical power supply, both from the Mains Distribution Panel in the room and on the Page no. 1611 JC-DR-A-412.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A412 - Anode Starter Board 300-PL2 rotary switch in the Generator cabinet (position I). 5. Switch on the Senographe system electrical power (i.e. Generator, Gantry, and Control Station). Wait until the Gantry boot is complete, and check that no error has been reported. 6. Reinstall the Generator covers (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513). 7 COMPLETION None. Chapter 9 Page no. 1612 JC-DR-A-412.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A413 - BT Power Supply 400-T1 Job Card D/R A413 - BT Power Supply 400-T1 1 • Chapter 9 SUPPLIES BT Power Supply Board 400-T1 2 • TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 20 minutes 4 SAFETY PRECAUTIONS Steps in this Job Card tell you when to take appropriate action to avoid electric shock. 5 PREREQUISITES None 6 PROCEDURE 6-1 Removal of the BT Power Supply 1. Switch off the electrical power supply from the Mains Distribution Panel in the room. Apply an appropriate LOTO padlock and label. Wait 10 minutes for the components within the Generator to discharge. WARNING It is important that you switch off the external power supply on the Mains Distribution Panel. This is because you will be working in close proximity to where the external voltage arrives into the Generator. 2. Remove the four Generator side panels (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513) to reveal the BT Power Supply. 3. Switch off the electrical power supply on the rotary switch in the Generator cabinet (position 0). Page no. 1613 JC-DR-A-413.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A413 - BT Power Supply 400-T1 4. Using a voltmeter (rating 1000 V DC), check that there is no residual voltage between screws S1 and S2 before proceeding. RC1 RC2 S1 S2 WARNING Residual voltage stored in the resonant capacitors can be dangerous. Ensure that the resonant capacitors are fully discharged before you handle the BT Power Supply. 5. Remove the four bolts (1) (5 mm open ended wrench) which secure the BT Power Supply protective cover to the Generator chassis. 2 1 1 2 6. Remove the two cables from the BT Power Supply. Ensure that you do not move them too much so they are easier to re-connect later on. 7. Remove the allen screws (2) (2.5 mm open ended wrench) which attach the BT Power Supply to the Generator chassis. Chapter 9 Page no. 1614 JC-DR-A-413.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A413 - BT Power Supply 400-T1 8. Remove the faulty BT Power Supply from the Generator chassis and put it in an anti-static bag. 6-2 Installation of the BT Power Supply 1. Carefully place the new BT Power Supply on the Generator chassis. Ensure that the holes for the four bolts line up with the four threads on the Generator chassis. 1 2 Top 2 1 Bottom 2. Attach the four allen screws (1) (2.5 mm allen wrench) to secure the BT Power Supply to the Generator chassis. 3. Connect all the cables to the new BT Power Supply as summarized in the diagram above and table below. Connector Location Description of cable (usually identified by code on a white label) Cable color Top 400 T1 CN1 Black Bottom 400 T1 XJ2 Black 4. Attach the four bolts (2) (5 mm open ended wrench) to secure the BT Power Supply protective cover to the Generator chassis. 5. Switch on the electrical power supply, both from the Mains Distribution Panel in the room and on the Page no. 1615 JC-DR-A-413.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A413 - BT Power Supply 400-T1 rotary switch in the Generator cabinet (position I). 6. Switch on the Senographe system electrical power (i.e. Generator, Gantry, and Control Station). Wait until the Gantry boot is complete, and check that no error has been reported. 7. Reinstall the Generator covers (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513). 7 COMPLETION None. Chapter 9 Page no. 1616 JC-DR-A-413.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A414 - Power Line Filter Box Job Card D/R A414 - Power Line Filter Box 1 SUPPLIES • Power Line Filter Box 2 • Chapter 9 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 40 minutes 4 SAFETY PRECAUTIONS Steps in this Job Card tell you when to take appropriate action to avoid electric shock. 5 PREREQUISITES None 6 PROCEDURE 6-1 Removal of the Power Line Filter 1. Switch off the electrical power supply from the Mains Distribution Panel in the room. Apply an appropriate LOTO padlock and label. Wait 10 minutes for the components within the Generator to discharge. WARNING It is important that you switch off the external power supply on the Mains Distribution Panel. This is because you will be working in close proximity to where the external voltage arrives into the Generator. 2. Remove the four Generator side panels (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513) to reveal the Power Line Filter. 3. Switch off the electrical power supply on the rotary switch in the Generator cabinet (position 0). Page no. 1617 JC-DR-A-414.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A414 - Power Line Filter Box 4. Using a voltmeter (rating 1000 V DC), check that there is no residual voltage between screws S1 and S2 before proceeding. RC1 RC2 S1 S2 WARNING Residual voltage stored in the resonant capacitors can be dangerous. Ensure that the resonant capacitors are fully discharged before you handle the Relay board and Power Line Filter. 5. Switch off the external power supply that runs between the room lamps and the cables (1) that are connected to the Generator Relay board. WARNING The lamp cables contain a live voltage from an external source. It is important that you switch off the external power supply to the lamp cables because you will be handling them in order to remove Generator Relay board. 4 3 ! 2 Ensure that the external power from the room Mains Distribution Panel has been switched off before you start to handle the Line Supply Cables. 4 1 6. The Generator Relay board is located on the side of the Generator, behind the Generator Interface board. Make a note of the Generator Relay board current lamp and door cable configuration. The configuration determines how the room lamps and door operate with the Senographe system for that Chapter 9 Page no. 1618 JC-DR-A-414.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A414 - Power Line Filter Box particular customer. Disconnect the room and door cables (1) from the Generator Relay board. 7. Disconnect the Line Supply Cables (2) from the Power Line Filter. 8. Carefully disconnect the data cable (3) from the Generator Relay board. Ensure that you do not move it too much so it is easier to re-connect it later on. ! Notice: Disconnect with caution to avoid damage to the connectors and cables. 9. Remove the four screws (4) that secure the Generator Relay board (4 mm allen wrench) to the Generator chassis, and carefully remove the Generator Relay board. 10. Put the Generator Relay board in an anti-static bag in a safe place. 11. Disconnect the earth cable lablelled FILTRE (5) from the Power Line Filter (4 mm open ended wrench). 5 12. Disconnect the allen screw (6) from the left side of the Power Line Filter (3 mm allen wrench). 6 13. Disconnect the two allen screws (7) from the right side of the Power Line Filter (4 mm allen wrench). Page no. 1619 JC-DR-A-414.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A414 - Power Line Filter Box Access to these allen screws is underneath the Generator framework. 7 14. Carefully remove the faulty Power Line Filter from the Generator by lifting it and turning it clockwise. 6-2 Installation of the Power Line Filter 1. Carefully put the new Power Line Filter into the Generator by turning it anti-clockwise so that it screw threads line up with the holes on the Generator framework. 1 2. Use the two allen screws (1) to secure the right side of the Power Line Filter to the Genrator base (4 mm allen wrench). These allen screws point upwards with their heads underneath the Generator framework. 3. Use the allen screw (2) to secure the left side of the Power Line Filter to the Generator Framework Chapter 9 Page no. 1620 JC-DR-A-414.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A414 - Power Line Filter Box (3 mm allen wrench). 2 4. Connect the earth cable lablelled FILTRE (3) to the Power Line Filter (4 mm open ended wrench). 3 5. Carefully place the Generator Relay board (that you removed from the faulty Power Line Filter) on the new Power Line Filter. Ensure that the holes for the four allen screws line up with the four threads Page no. 1621 JC-DR-A-414.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A414 - Power Line Filter Box on the Power Line Filter. 4 5 ! 7 Ensure that the external power from the room Mains Distribution Panel has been switched off before you start to handle the Line Supply Cables. 4 6 6. Attach the four allen screws (4) (4 mm allen wrench) to secure the Generator Relay board to the Power Line Filter. 7. Carefully re-connect the data cable (5) to the Generator Relay board. The red line of the ribbon cable must be on the right-hand side of the connector. 8. Reconnect the lamp and door cables (6) exactly how they were connected before. 9. Reconnect the Line Supply Cables (7) from the Mains Distribution Panel to the Power Line Filter. 10. Ensure that a cable tie is present to secure the Line Supply Cable to the lower cross-member of the Generator framework. Cable Tie 11. Re-establish the external power supply to the room lamps. 12. Switch on the electrical power supply, both from the Mains Distribution Panel in the room and on the Chapter 9 Page no. 1622 JC-DR-A-414.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A414 - Power Line Filter Box rotary switch in the Generator cabinet (position I). 13. Switch on the Senographe system electrical power (i.e. Generator, Gantry, and Control Station). 14. Wait until the Gantry boot is complete, and check that no error has been reported. 15. Reinstall the Generator covers (see Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513). 7 COMPLETION None. Page no. 1623 JC-DR-A-414.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A414 - Power Line Filter Box This page is blank. Chapter 9 Page no. 1624 JC-DR-A-414.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A415 - Generator Board CPU EEPROMs Job Card D/R A415 - Generator Board CPU EEPROMs 1 SUPPLIES 1-1 Identify the system level Chapter 9 1. Determine your system level by accessing the Service Desktop, by clicking the Tools menu button then Service Desktop in the drop-down menu. Note: If the generator is not working and you consequently cannot access the Service Desktop, skip this step and directly refer to the reference of the current Generator CPU board and to section 1-2 Ordering the applicable EEPROM kit on page 1625. 2. Make a note of the Generator version. You will need this information later on to make sure no problems occurred after the EEPROMs are replaced. 1-2 Ordering the applicable EEPROM kit Based on the following chart, order the applicable EEPROM kit, to be chosen from the following three: • P/N 5405814 - for DS systems up to but not including Penduick • P/N 5411745 - for Penduick, Z400 and Sunburst DS systems System Type System version Current Generator CPU Board reference Reference of EEPROMs set to be used/ordered Core DS IS4-3 (2383168-5 and lower*) 2385602-8 5405832 (part of set of EEPROMs 5405814) Core DS Orion1 Nephtys M412s1 Nephtys M413 (2383168-6) 2385602-9 5405833 (part of set of EEPROMs 5405814) 2385602-11 5411745 Core DS Penduick (2383168-7) Z400 (2383168-8) 5411745 Core DS 2385602-11 Sunburst (2383168-9) * With the complete rollout of FMI12075, all systems in the field are at least at an IS4-3 system level. Note: if you do not know the version of your system, ignore the System version column and refer only to the Current CPU board reference column. Note: If the Generator CPU Board is also faulty, in addition to the EEPROM Kit, also order the empty Generator CPU board (5399150) and perform this Job Card in conjuction with Job Card D/R A401 - Generator CPU Board 400PL3 on page 1543. Page no. 1625 JC-DR-A-415.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A415 - Generator Board CPU EEPROMs 2 APPLICABILITY This Job Card applies to the core product. If the system has the CESM option, perform the CESM version of this Job Card located in the CESM SIP instead. 3 TOOLS PLCC chip extraction tool (91729294) 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 1.5 hour 5 SAFETY PRECAUTIONS WARNING FOR OPERATOR SAFETY, THIS UPGRADE REQUIRES STRICT APPLICATION OF LOCKOUT/TAG-OUT (LOTO) PROCEDURE. ! Notice: When handling circuit boards, take precautions against damage by ESD (electrostatic discharge). ! Notice: Generator parameters are saved in the NV-RAM of the Generator CPU Board. If possible, ensure that a backup of these parameters has been made before removing the board. If not, it will be necessary to reconfigure the Generator after changing the board. To backup the NV-RAM of the Generator CPU Board, perform a full system back-up according to Job Card ELE A052 - Back-up/ Restore Procedure on page 771. Note: For Senographe systems that use AWS V43.0 or later (on the SB150) or AWS 53.0 or later (on the U20), or AWS 54.10 or later (on the Z400), consult the site System Configuration Form to determine the current AOP configuration for all three modes (DOSE, STD, and CNT) on the Generator. 6 PREREQUISITES If possible, ensure that a backup of the Generator parameters has been made before removing the board. If not, it will be necessary to reconfigure the Generator after changing the board. To backup the NV-RAM of the Generator CPU Board, perform a full system back-up according to Job Card ELE A052 Back-up/Restore Procedure on page 771. Chapter 9 Page no. 1626 JC-DR-A-415.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A415 - Generator Board CPU EEPROMs 7 PROCEDURE 7-1 Remove the Existing EEPROMs on the Generator CPU Board 1. Switch off the electrical power supply from the Mains Distribution Panel in the room. Apply an appropriate LOTO padlock and label and open the circuit breaker at the bottom part of the Generator. Wait 10 minutes for the components within the Generator to discharge. 2. Remove the Generator front panel (CPU side) to reveal the Generator CPU board 400PL3; refer to Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513. 3. With the EEPROM removal tool, on the Generator CPU board taking care of components around, remove slowly the four EEPROMs B43, B44, B48 and B49. 4. Remove the X2 jumper for 10 seconds and plug it back into the X2 pins again in horizontal position. This action erases the NV RAM content. 7-2 Install New EEPROMs on the Generator CPU Board New PROMs may have pins set too far apart. Tighten them smoothly, as shown below. 1. Taking care not to damage the pins of the EEPROMs, insert the four new EEPROMs into the new generator CPU board. Refer to Table 1 on page 1628 and to Illustration 1 on page 1629 to identify the applicable EEPROMs and the sockets into which they must be inserted: Page no. 1627 JC-DR-A-415.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A415 - Generator Board CPU EEPROMs TABLE 1 - GENERATOR CPU BOARD EEPROMS AND CORRESPONDING SOCKETS Generator version Set of EEPROMs 4.02 CMN Chapter 9 Corresponding board socket 2385604-8 B43 2385605-8 B44 2385606-8 B48 2385607-8 B49 2385604-9 B43 2385605-9 B44 2385606-9 B48 2385607-9 B49 EEPROM kit 1.10 CMN 3.02 CMN EEPROM P/N 5405832 5405814 5411745 5405833 NA 2385604-11 B43 2385605-11 B44 2385606-11 B48 2385607-11 B49 Corresponding label reference to stick on Generator CPU Board 2385602-8 2385602-9 2385602-11 Page no. 1628 JC-DR-A-415.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A415 - Generator Board CPU EEPROMs ILLUSTRATION 1 - LAYOUT OF THE GENERATOR CPU BOARD B49 socket B48 socket B44 socket B43 socket Take great care to respect the orientation of the EEPROMs. Ensure that the small notch of the EEPROM is above the small notch on the Generator CPU Board. Do not trust label orientation on the Page no. 1629 JC-DR-A-415.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A415 - Generator Board CPU EEPROMs orientation on the EEPROM, as the label could have been stuck upside down. Each EEPROM can be easily inserted by positioning first the lower part of pins and then press smoothly to get pins into the upper part. 2. Visually inspect that the four EEPROMs are completely inserted in the sockets of the Generator CPU Board. Note: If the label that is already on the Generator CPU Board is the same as the label supplied with the EEPROMs, the step below to stick this label is not necessary. 3. When the 4 EEPROMs are inserted, stick the appropriate Generator label contained in the EEPROM set on the Generator CPU board (see Table 1 on page 1628 for the Generator label references). 7-3 Restore Generator Parameters 1. Switch on the Senographe electrical power. 2. Before restoring the NV-RAM on the Generator CPU Board, you must erase the NV-RAM content. On the Generator CPU Board to the left of the battery, remove the X2 jumper for 10 seconds and plug it back into the X2 pins again in horizontal position. 3. Restore the Generator parameters as described in Job Card ELE A052 - Back-up/Restore Procedure on page 771. 4. Restoring the Generator parameters will restore all the parameters except the X-ray Tube Heater calibration. You must perform an automatic calibration of X-ray Tube Heater current in large and small focus. Refer to Job Card CAL A012 - X-Ray Tube Heater Current on page 1673. The small focus heater calibration requires a Mag stand or a Mag Stand simulator. 5. Because the NV-RAM was reset, the current language setting for the Generator was erased. You must re-configure the preferred language setting for the Generator according to section 4-2, Set Language in Job Card ELE A009 - Generator Configuration on page 561. Chapter 9 Page no. 1630 JC-DR-A-415.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A415 - Generator Board CPU EEPROMs 8 COMPLETION If no Generator parameter backup is available, or the restore is not successful, the Generator must be reconfigured. If Generator reconfiguration is necessary: • Carry out the following calibrations: Calibrations - Checks Job Card Acquisition Image Chain Heating Current Calibration Job Card CAL A001 - Heater Current Scale Factor on page 1649 Bias Calibration Job Card CAL A003 - X-Ray Tube Focal Bias Voltage Scale Factor on page 1655 Tube mA Measurement Job Card CAL A009 - X-Ray Tube mA Measurement on page 1663 kV Scale Factor Job Card CAL A011 - Calibration of kV Scale Factor on page 1667 mAs X-ray Calibration Job Card CAL A012 - X-Ray Tube Heater Current on page 1673 Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration on page 1693 Gain calibration Job Card CAL A043 - Detector Gain Calibration on page 1697 flat field tests Job Card ELE A032 – IQ Tools Flat Field Test on page 699 If IQ Tests not OK, repeat all calibrations from Bad Pixel. Half Value Layer Job Card CAL A046 - Half-Value Layer Measurement on page 1703 Conversion Factor Job Card CAL A045 - Conversion Factor Measurement on page 1701 Use the same dosimeter as that used for CAL A046 AOP: Automatic Optimization of Parameters AOP Calibration Job Card CAL A051 - AOP Calibration on page 1723 mAs non linearity Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 AOP/SNR Check Job Card ELE A038 - AOP Mode and SNR Check on page 707 If AOP/SNR Test not OK, repeat all calibrations from AOP Calibration. • • For Senographe systems that use AWS V43.0 or later (on the SB150) or AWS 53.0 or later (on the U20), or AWS 54.10 or later (on the Z400), if the Senographe system does not use the default AOP Classic (AOP A) tables configuration, restore as necessary the AOP configuration (see Job Card ELE A031 - AOP Configuration on page 693). For Senographe systems that use AWS 53.40 or later, which have the Stereotaxy option installed and do not use the default AOP Profile (AOP B) tables for AOP stereo mode, restore the AOP stereo Configuration according to Job Card IST A003 AOP Configuration, as described in the Senographe DS Stereotaxy Service Manual. Page no. 1631 JC-DR-A-415.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A415 - Generator Board CPU EEPROMs This page is blank. Chapter 9 Page no. 1632 JC-DR-A-415.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A421 - Conditioner Unit Job Card D/R A421 - Conditioner Unit 1 SUPPLIES • • Conditioner unit Coolant kit 2 TOOLS • • 3 Chapter 9 Standard Tool Box Purge Tool REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 • • SAFETY PRECAUTIONS When filling the Conditioner, take great care to keep coolant away from the vents, the ON/OFF switch and the power cord connection. Do not immerse the Conditioner in any liquid. Dispose of surplus coolant with care as described in the section Surplus Coolant Disposal; refer to the Caution below. CAUTION • Before adding coolant to the Conditioner, always switch OFF the Generator and MDR circuit breakers in the Generator Cabinet. Switch on the MDR breaker only as instructed. • Always use a funnel when adding coolant to the Conditioner. • Always wear protective gloves and goggles when working with coolant. • When working with coolant you should treat it with care; avoid unnecessary contact . See below for First Aid advice: First Aid in case of contact with Conditioner coolant: Immediately flush eyes or skin with plenty of water for at least 15 minutes. If coolant contacts the eye, call a physician immediately. If coolant is swallowed, drink one to two glasses of water or milk. Avoid alcohol. Call a physician immediately. Remove and wash contaminated clothing before reuse. Page no. 1633 JC-DR-A-421.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A421 - Conditioner Unit n 5 PREREQUISITES Remove Generator Cabinet covers as required for access. See Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513. 6 PROCEDURE 6-1 Preparation - Conditioner Drain To drain the Conditioner, proceed as follows: 1. Shut down the entire system by clicking the System Shutdown button on the Browser window. 2. Switch OFF the Generator and MDR circuit breakers in the Generator Cabinet. 3. Prepare the Empty container to receive the used coolant. Place the end of the purge tool into the container. 4. Disconnect the coolant input pipe from the Conditioner. The pipe connector seals automatically. 5. Connect the disconnected coolant input pipe to the purge tool. The connector is now unsealed, and coolant can drain into the prepared container. 6. Switch ON the MDR circuit breaker and press the Conditioner ON button in the generator cabinet. 7. Coolant drains into the container, until the “Check Fluid” alarm stops the flow. 8. Switch OFF the MDR circuit breaker. Note: The Conditioner is now empty. 9. Label the container containing the drained coolant to indicate the nature of its contents; cross out the word Empty on the label, and copy the information from one of the coolant containers (Flush or Topping) provided in the kit. See below for disposal. Chapter 9 Page no. 1634 JC-DR-A-421.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A421 - Conditioner Unit 6-2 Disassembly of Conditioner • Before beginning work, shut down correctly the equipment and switch OFF the Senographe hospital supply circuit breaker. Lock it in the OFF position or mark it clearly with a warning sign to prevent others from applying power. 1. Locate the Conditioner unit (1) in the Mains Distribution Rack. 2. Disconnect serial line connector from the Conditioner unit. 3. Disconnect the two coolant pipes from the Conditioner unit. Note: The coolant pipe connectors are self-seal- 1 ing. 4. Disconnect the AC Mains cable connector. 5. Remove the two front screws (2) and the two rear screws (3) securing the Conditioner unit to the generator support. Note: Some systems use a nylon strap to secure the Conditioner instead of the four screws. 2 3 Page no. 1635 JC-DR-A-421.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A421 - Conditioner Unit 6. Loosen, without removing, screw (4) securing air duct (5) in place, then carefully remove air duct. 7. Remove defective Conditioner unit from the Generator cabinet by pulling it through the left side of the generator chassis. 6-3 5 4 Reassembly Reverse the disassembly procedure. 6-4 Coolant Fill A document describing an alternate procedure is provided in the coolant kit. For maximum safety and minimum risk of spillage during coolant installation, we recommend using the procedure given below: 1. Before beginning, check the color of the coolant provided in the kit. It must be blue for a non-mobile system. 2. Check that all hoses are correctly connected. 3. Remove the reservoir cap, then slowly add liquid from the container labelled Topping to the reservoir until the liquid reaches the bottom of the cap threads. The total capacity of the cooling system is approximately 500 ml (1 pint). 4. Switch on the unit (switch ON the MDR circuit breaker and press the Conditioner ON button in the generator cabinet). 5. As the coolant circulates and air bubbles are flushed from the system, the coolant level falls. Add liquid as necessary until the level is steady at the bottom of the cap threads. 6. Replace the reservoir cap when you are satisfied that the level is correct. 6-5 • MDR Breaker ON/OFF push buttons: Conditioner and MDR Conditioner Detector supply Control Station UPS Generator Generator Breaker Functional check Switch ON the Senographe electrical power. Chapter 9 Page no. 1636 JC-DR-A-421.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A421 - Conditioner Unit • • • Check that the Conditioner display shows the message IDC CONTROL for about 5 seconds shortly after the system is switched on. Check that within about 15 minutes of operation manifold temperature shown on the Conditioner display is 26°C +2°C. About 15 minutes after the system is operational, make an exposure; verify that the exposure proceeds correctly, with no warning message displayed after the acquisition. 6-6 • • Surplus Coolant Disposal In a normal non-sensitive environment, used and surplus coolant may be disposed of by pouring down a drain. Triple-rinse containers before placing them in appropriate waste receptacles. 7 COMPLETION None Page no. 1637 JC-DR-A-421.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card D/R A421 - Conditioner Unit This page is blank. Chapter 9 Page no. 1638 JC-DR-A-421.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Configuration guide CONFIGURATION GUIDE CHAPTER 9 Configuration information is given in the following module: - Job Card CFG A001 - Software Reload on page 1641 Job Card CFG A070 - Deactivate Contrast Mode on page 1645 Page no. 1639 Configuration.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Configuration guide This page is blank. Chapter 9 Page no. 1640 Configuration.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CFG A001 - Software Reload Job Card CFG A001 - Software Reload 1 Chapter 9 SUPPLIES Software kits supplied with the system 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 3 to 4 hours 4 SAFETY PRECAUTIONS No specific safety precautions are applicable. 5 • PREREQUISITES Wherever possible, a full system backup must be available from either a floppy diskette or a CD-R. Refer to Job Card ELE A052 - Back-up/Restore Procedure on page 771. Make a backup of the Repeat and Reject Analysis database. Use the AWS Export Database feature as described in the chapter QC Tests for the Radiologic Technologist of the Senographe DS QC Manual • ! Notice: If there is a system failure that results in the loss of information from the Repeat and Reject Analysis database, an entry must be recorded in the QC log. This QC log entry must describe the occurrence and the cause of data loss, to provide documentation on the reasons for which an analysis may not be available in a particular period. A Field Service record must also be prepared to indicate the nature of the failure and loss of information. 6 AWS SOFTWARE 6-1 AWS Full Software Reload ! Notice: When reloading system software from cold (i.e., including the operating system), first disconnect the cable to the external network, and configure the system as "not networked". When the procedure is complete, connect the cable and configure the system as "networked" before executing the following procedure. • A full AWS software reload (operating system and application software) is necessary in some cases. For example, the AWS unit has been replaced, or if lost or corrupted files make it impossible to run the application after rebooting, and reloading the application only is not successful. Use the same AWS software CD-ROMs as used for the current installation (supplied with the system or supplied for a software update). CAUTION If reloading software after a system crash or after replacement of the AWS, it is important to load the same software version as that was previously installed. Page no. 1641 JC-CFG-A-001.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CFG A001 - Software Reload • • Follow the Install from scratch instructions given in the booklet supplied with the AWS Application Software CD-ROM to install the software. Before starting the procedure, take note of the requirements for Material needed. After completing the installation, Refer to Job Card ELE A052 - Back-up/Restore Procedure on page 771: - Restore AWS parameters from the system backup on the backup media (either floppy diskette or CD-R). If this backup media is not available, the procedures given in the Job Card ELE A013 AWS Configuration on page 573 must be carried out. - Back up the system configuration to a floppy diskette or a CD-R. ! Notice: If the system backup is not done, no backup for IDC and Senographe parameters will exist. • For V3 Control Stations that use AWS V53.10.10 or later and V4 Control Stations, install the Embedded Publications, see Job Card ELE A044 - Install User Publications on page 755. • For Senographe systems that use AWS V43.0 or later (on the SB150) or AWS 53.0 or later (on the U20) or AWS 54.10 or later (on the Z400), if the Senographe system does not use the default AOP Classic (AOP A) tables configuration, restore as necessary the AOP configuration (see Job Card ELE A031 - AOP Configuration on page 693). 6-2 • • • AWS Application Reload or Update To reload the Application software only, or if a new version of application software must be installed on your system, use the AWS Application Software CD-ROM used for the current installation, or that provided for the update, and follow the Update from CD-ROM instructions given in the CD-ROM booklet. For V3 Control Stations that use AWS V53.10.10 or later and V4 Control Stations, reinstall the Embedded Publications, see Job Card ELE A044 - Install User Publications on page 755. For Senographe systems that use AWS V43.0 or later (on the SB150) or AWS 53.0 or later (on the U20) or AWS 54.10 or later (on the Z400), if the Senographe system does not use the default AOP Classic (AOP A) tables configuration, restore as necessary the AOP configuration (see Job Card ELE A031 - AOP Configuration on page 693). 7 IDC SOFTWARE 7-1 IDC Software Reload or Update from CD-ROM Software reload from CD-ROM is necessary when the IDC Computer has been replaced, or if a new version of the IDC software must be installed on your system. Use the following steps to perform an IDC Software Reload: 1. Back up the system configuration (including the IDC configuration) to the AWS hard disk. Refer to Job Card ELE A052 - Back-up/Restore Procedure on page 771. 2. Follow the installation instructions given on the back of the CD-ROM case of the IDC Application Software CD-ROM used for the current installation or supplied for a software update. 3. Restore the IDC directory data from the current system backup from the AWS hard disk. Refer to Job Card ELE A052 - Back-up/Restore Procedure on page 771. 4. Reload the detector paramaters according to Load Detector Parameters on page 1103 in Job Card D/R A141 - Image Receptor/Digital Detector (requires the floppy disk or CD-ROM containing parameters for the detector). Chapter 9 Page no. 1642 JC-CFG-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CFG A001 - Software Reload 7-2 IDC Data Restore from Backup If lost or corrupted files make it impossible to run the application after rebooting, restore the IDC directory data from the current system backup. Refer to Job Card ELE A052 - Back-up/Restore Procedure on page 771. 8 SENOGRAPHE PARAMETERS 8-1 Senographe Software Reload • • If Senographe parameters have been lost or corrupted, reload them from the current system backup. Refer to Job Card ELE A052 - Back-up/Restore Procedure on page 771. If the backup is not available, it will be necessary to recalibrate the Senographe. Page no. 1643 JC-CFG-A-001.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CFG A001 - Software Reload This page is blank. Chapter 9 Page no. 1644 JC-CFG-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CFG A070 - Deactivate Contrast Mode Job Card CFG A070 - Deactivate Contrast Mode 1 Chapter 9 SUPPLIES None 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 1 minute 4 SAFETY PRECAUTIONS None 5 PRE-REQUISITES None 6 APPLICABILITY In case of site specific requirements, the access to CNT mode can be restricted as described in this Job Card. 7 TO DEACTIVATE THE CONTRAST MODE Deactivate Contrast mode (CNT) by entering the command GENE/INSTAL/GENE/AOP/CNT/NO on the X-ray Console. Page no. 1645 JC-CFG-A-070.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CFG A070 - Deactivate Contrast Mode This page is blank. Chapter 9 Page no. 1646 JC-CFG-A-070.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Calibration guides CALIBRATION GUIDES CHAPTER 9 Calibration information is given in the following modules: - Job Card CAL A001 - Heater Current Scale Factor on page 1649 Job Card CAL A003 - X-Ray Tube Focal Bias Voltage Scale Factor on page 1655 Job Card CAL A007 - Automatic X-ray Tube Warm-Up on page 1661 Job Card CAL A009 - X-Ray Tube mA Measurement on page 1663 Job Card CAL A011 - Calibration of kV Scale Factor on page 1667 Job Card CAL A012 - X-Ray Tube Heater Current on page 1673 Job Card CAL A021 - Arm Rotation Calibration on page 1679 Job Card CAL A027 - Tube Tilt Calibration on page 1681 Job Card CAL A029 - Collimator Format Calibration on page 1683 Job Card CAL A031 - Lift Calibration on page 1687 Job Card CAL A041 - Bad Pixel Calibration on page 1693 Job Card CAL A043 - Detector Gain Calibration on page 1697 Job Card CAL A045 - Conversion Factor Measurement on page 1701 Job Card CAL A046 - Half-Value Layer Measurement on page 1703 Job Card CAL A048 - Calibration of Compression Force Sensor on page 1709 Job Card CAL A049 - Compression Paddle Offset Calibration on page 1711 Job Card CAL A050 - Compression Thickness Calibration on page 1721 Job Card CAL A051 - AOP Calibration on page 1723 Job Card CAL A053 - mAs Non-linearity Calibration on page 1725 Page no. 1647 Calibration.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Calibration guides This page is blank. Chapter 9 Page no. 1648 Calibration.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A001 - Heater Current Scale Factor Job Card CAL A001 - Heater Current Scale Factor 1 Chapter 9 SUPPLIES None 2 TOOLS • • Multimeter (Fluke 87) or a multimeter that can operate in true RMS AC ammeter mode (e.g.: Fluke 8060). HV unit/cable adaptor ! Notice: IMPORTANT NOTE: To ensure accurate measurement: • For ALL Digital Multimeters: The Autorange function MUST NOT be used, as it can lead to severe measurement errors (>40%). • For ALL Digital Multimeters: The Relative Measurement function MUST NOT be used to reset to zero the natural offset displayed when there is no current measured. The offset is automatically reset to zero by the principle of the rms measurement. • Measurement configurations to be used are as follows: - Fluke 87: no shunt, in the 10 A AC range. - Fluke 8060: used with 20 A shunt in the 200 mV AC range (shunt reference: 80J10). 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 67 minutes 4 SAFETY PRECAUTIONS CAUTION In case of equipment breakdown or service engineer error during this calibration procedure, the resulting parameter values might become so unreasonable as to render the X-ray tube filament supply circuit unusable. This can show up as an error message during power up, and thus inhibit use of the calibration software. If this happens, the only way to cancel the error is to manually re-enter the default parameter values (see section 6 for default parameter values), and then switch the Senographe off and back on again before again attempting a calibration. 5 PREREQUISITES None 6 CALIBRATION OF HEATER CURRENT SCALE FACTOR The objective is to determine the scale factor K and fixed offset VOF between the X-ray tube filament current command from the software and the real filament current value obtained. Each tube track has its own filament supply circuit, so this calibration procedure is to be performed for each of the two tracks. DEFAULT PARAMETER VALUES ARE K = +9.450E+0 (9.45) AND VOF = +0.000E+0 (0.0). Page no. 1649 JC-CAL-A-001.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A001 - Heater Current Scale Factor 6-1 Preparation 1. Turn the Senographe OFF. 2. Open the HV converter control signal inputs by disconnecting flat cable WG8 from generator command board 400-PL1 connector XJ7. This eliminates any possibility of energy build-up in the HV unit during this calibration procedure. 3. Disconnect the Senographe HV cable at the HV tank end. 4. Connect the HV cable to the HV unit HV cable adaptor (36003399). 5. Connect the HV unit HV cable adaptor to the Senographe HV tank. 6. Connect the multimeter (running in true RMS AC ammeter mode) in series with the filament being calibrated on the HV unit/cable adaptor; and place a jumper on the other track (see illustrations 1 and 2). Note: 1. See “important note” in section 2 to ensure an accurate measurement. 2. Keep the other filament connected in order to avoid error messages when the Senographe is switched on. ILLUSTRATION 1 - HV UNIT HV CABLE ADAPTOR 36003399 Track 2 (Rh): jumper or ammeter From HV tank To X Ray tube HV cable shield -HT -HT C C TRACK 2 (Rh) TRACK 2 (Rh) TRACK 1 (Mo) TRACK 1 (Mo) L L S S BIAS BIAS G G Ground (+HV) Ground (+HV) C G Bias measurement Track 1 (Mo): jumper or ammeter Note: For safety reasons, -HT is permanently connected to ground ILLUSTRATION 2 - HV CABLE CONNECTOR PIN CONNECTION DIAGRAM L NOTE: THIS IS A HEAD-ON VIEW OF THE HV CABLE CONNECTOR AFTER BEING DISCONNECTED FROM THE HV UNIT. G POLARIZING TAB C S The HV cable connector is marked with the standard X-ray industry markings (L, S, C, and G). However, the functions of the corresponding conductors in the Senographe are as follows: Chapter 9 Page no. 1650 JC-CAL-A-001.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A001 - Heater Current Scale Factor L = track 1 (Mo) filament supply S = track 2 (Rh) filament supply C = filament supply return and X-ray tube cathode HV G = focal bias voltage supply 7. Switch on the Senographe. Note: ERROR 007/024 is normal with 400 PL1 XJ7 disconnected. 6-2 Perform the calibration procedure for the desired X-ray tube track. When you follow the procedure in section 6-2-2, Perform the Calibration Procedure on page 1651, you must take into account the corrections described in section 6-2-1, Measurement Correction on page 1651. 6-2-1 Measurement Correction • If you use a Fluke 87 first generation or a Fluke 87 type III, you must directly use the value measured by the tool. Do NOT apply any correction. • If you use a Fluke 87 type 5, you must add the following offset value to the value read on the Fluke. If the measurement taken at Add the following offset value 4A 0.18 5A 0.2 The following example illustrates the described solution: • For 4A measurement, if the value read at Fluke is equal to 3.85A, add 0.18. So, the final value is 4.03A. • For 5A measurement, if the value read at Fluke is equal to 4.85A, add 0.2. So, the final value is 5.05A. Note: Correction factors are recommended by FLUKE in their datasheet in the case of Non-sinusoidal waveforms. These correction factors have been obtained statistically by Engineering by comparing correct measurement (from 87 III, scope and other accurate millimeters) with 87 V. They are required because the measured signal is not sinusoidal. The signal is discontinued 20A Pulsed. The Fluke 87 V is not able to retrieve the proper RMS value with the Senographe DS Ampere waveform. 6-2-2 Perform the Calibration Procedure 1. Select SETUP/GENE/INSTAL/GENE/GENE/HTR_SCL/TRACK1 (or TRACK2) /CALIB/1st pt/ CALIB on the X-ray Console for the first calibration point. Note: The default filament current command value for this first point is +4.000E+00 (4.0) A. 2. Press the Exposure button on the X-ray Console (no X-rays are produced) and hold it until the multimeter reading stabilizes (this may take a few seconds). 3. Note the filament current value measured from the multimeter. 4. If it is required to apply a correction to the measured value, follow the instructions given in section 62-1, Measurement Correction on page 1651. 5. Release the Exposure button . Page no. 1651 JC-CAL-A-001.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A001 - Heater Current Scale Factor 6. Select SETUP/MeasI on the X-ray Console. 7. Enter and confirm the measured filament current value from the multimeter for this first calibration point. 8. Select SETUP/SETUP/2nd pt/CALIB on the X-ray Console for the second calibration point. Note: The default filament current command value for this second point is +5.000E+00 (5.0) A. 9. Press the Exposure button on the X-ray Console (no X-rays are produced); hold it until the ammeter reading stabilizes (this may take a few seconds). 10. If it is required to apply a correction to the measured value, follow the instructions given in section 62-1, Measurement Correction on page 1651. 11. Note the filament current value measured by the multimeter. 12. Release the Exposure button . 13. Select SETUP/Meas on the X-ray Console. 14. Enter and confirm the measured filament current value from the ammeter for this second calibration point. 15. Select SETUP/SETUP/calcul/VALID on the X-ray Console. This executes the calculation of the scale factor and fixed offset of the filament current command from the software. 6-2-3 Check the calibration accuracy. 1. Select SETUP/1st pt/CALIB on the X-ray Console. Note: Again, the default filament current command value for this first point is +4.000E+00 (4.0) A. 2. Press the Exposure button on the X-ray Console (no X-rays are produced) and hold it until the multimeter reading stabilizes (this may take a few seconds). 3. Note the filament current value measured from the multimeter. 4. Release the Exposure button . 5. Select SETUP/SETUP/2nd pt/CALIB on the X-ray Console. Note: Again, the default filament current command value for this second point is +5.000E+00 (5.0) A. 6. Press the Exposure button on the X-ray Console (no X-rays are produced) and hold it until the multimeter reading stabilizes (this may take a few seconds). 7. Note the filament current value measured from the multimeter. 8. Release the Exposure button . 9. Whatever Fluke 87 type is used (first generation, type 3 or type 5), the expected results are the following • 4.0 ±0.12 (+/-3%) A for the first point and • 5.0 ±0.15 (+/-3%) A for the second point If the results are within these tolerances, the calibration for this X-ray tube track is finished. If the results are out of tolerance, repeat the calibration procedure in section 6-2 and the check procedure in section 6-2-3 for the same X-ray tube track. Note: Performing the calibration procedure once is normally sufficient for correct calibration. If it is necessary to perform the calibration procedure more than once, the measured values of curChapter 9 Page no. 1652 JC-CAL-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A001 - Heater Current Scale Factor rent for the two points (4.0 and 5.0 A) should become increasingly accurate. If not, the procedure is probably not being followed correctly. 10. Select SETUP/SETUP/SETUP/PARAM on the X-ray Console. Note down the calculated values of scale factor K and offset VOF. The two values can be displayed alternately by rotating the X-ray Console kV dial. CAUTION If the value of K is less than +8.000E+0 (8.0), either the calibration procedure was done incorrectly or there is a hardware defect. 11. Repeat the calibration and check procedures on the other tube track, if necessary. 12. Perform a checksum (SETUP/GENE/INSTAL/CKSUM/CKSUM), then turn the system off. 13. Reconnect flat cable WG8 to generator command board 400-PL1 connector XJ7; Remove the high voltage cable adapter. Remember to secure the HV ring allen screw, to ensure proper ground continuity. 7 COMPLETION If you are handing the machine back to the user at this point, switch the Senographe off, then on again. Page no. 1653 JC-CAL-A-001.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A001 - Heater Current Scale Factor This page is blank. Chapter 9 Page no. 1654 JC-CAL-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A003 - X-Ray Tube Focal Bias Voltage Scale Factor Job Card CAL A003 - X-Ray Tube Focal Bias Voltage Scale Factor Chapter 9 1 SUPPLIES None 2 • • TOOLS Multimeter (Fluke 87) HV unit/cable adaptor 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 67 minutes 4 SAFETY PRECAUTIONS CAUTION In case of equipment breakdown or service engineer error during this calibration procedure, the resulting parameter values might become so unreasonable as to render the X-ray tube focal bias voltage supply circuit unusable. This can show up as an error message during power up, and thus inhibit use of the calibration software. If this happens, the only way to cancel the error is to manually re-enter the default parameter values (see section 6 for these values) and switch the Senographe off and back on again before attempting to repeat the calibration. 5 PREREQUISITES None 6 CALIBRATION OF X-RAY TUBE BIAS VOLTAGE SCALE FACTOR The objective is to determine the parameters I, J, K, L, M and N minimizing the difference between the Xray tube focal bias voltage command from the software and the real focal bias voltage value obtained. The focal bias voltage applied to the X-ray tube electron beam concentration device establishes the focal spot width. DEFAULT PARAMETER VALUES ARE - I=0.000E+0 - J=3.330E+2 (333) - K=8.440E+1 (84.4) - L=5.770E-2 (0.0577) - M=0.000E+0 - N=4.260E+2 (426). Page no. 1655 JC-CAL-A-003.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A003 - X-Ray Tube Focal Bias Voltage Scale Factor 6-1 Preparation 1. Turn the Senographe OFF. 2. Open the HV converter control signal inputs by disconnecting flat cable WG8 from generator command board 400-PL1 connector XJ7. This eliminates any possibility of energy build-up in the HV unit during this calibration procedure. 3. Disconnect the Senographe HV cable at the HV tank end. 4. Connect the HV cable to the HV unit / cable adaptor (36003399). 5. Connect the HV unit / cable adaptor to the Senographe HV tank. 6. Connect a multimeter (in DC voltmeter mode) between common (C) and the focal bias voltage wire (G) (see illustrations 1 and 2). ILLUSTRATION 1 - HV UNIT HV CABLE ADAPTOR 36003399 Track 2 (Rh): jumper or ammeter From HV tank To X Ray tube HV cable shield -HT -HT C C TRACK 2 (Rh) TRACK 2 (Rh) TRACK 1 (Mo) TRACK 1 (Mo) L L S S BIAS BIAS G G Ground (+HV) Ground (+HV) C G Bias measurement Track 1 (Mo): jumper or ammeter Note: For safety reasons, -HT is permanently connected to ground ILLUSTRATION 2 - HV CABLE CONNECTOR PIN CONNECTION DIAGRAM L NOTE: THIS IS A HEAD-ON VIEW OF THE HV CABLE CONNECTOR AFTER BEING DISCONNECTED FROM THE HV UNIT. G POLARIZING TAB C S The HV cable connector is marked with the standard X-ray industry markings (L, S, C and G). However, the functions of the corresponding conductors in the Senographe are as follows: L = track 1 (Mo) filament supply S = track 2 (Rh) filament supply C = filament supply return and X-ray tube cathode HVG = focal bias voltage supply Chapter 9 Page no. 1656 JC-CAL-A-003.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A003 - X-Ray Tube Focal Bias Voltage Scale Factor 6-2 Check focal bias command values 1. Switch on the Senographe. ERROR 007/024 is normal with 400 PL1 XJ7 disconnected. 2. Select SETUP/GENE/INSTAL/GENE/GENE/BIAS/VOLTAGE on the X-ray Console. 3. Rotate the kV dial in order to check that all four focal bias voltage command values are the same as the values specified on the label on the X–ray tube housing: MO/LF = (typical value is +70v) RH/LF = (typical value is +70v) MO/SF = (typical value is +250v) RH/SF = (typical value is +250v) Modify any values that appear different from these on the tube label by using the CHANGE key, rotating the kV dial and using the NEXT, VALID and SETUP keys. See Display of Parameter Values on page 96 and Modification and Entry of Values on page 96. Note: The bias voltages are repeated on a label inside the generator, above the CPU board. 6-3 Calibration procedure 1. Open the work list and declare a new Patient called "X-ray Tube BIAS cal". 2. Select SETUP/CALIB/100TH-M1/PARAM on the X-ray Console. 3. Select and change I and J with values written on the Generator Command Board 400-PL1, I is between -1 and -0.5, J is between 240 and 400. ! Notice: Even if the I and J values are the same, you must re-enter them otherwise you will not be able to perform the calibration. 4. First calibration point: a. Select SETUP/SETUP/CALIB/1st pt/CALIB on the X-ray Console; press the Exposure button on the X-ray Console (no X-rays are produced) and hold it until the voltmeter reading stabilizes. b. Note the focal bias voltage value measured from the voltmeter; release the Exposure button . c. Select SETUP/MEASV on the X-ray Console. d. Enter and confirm the measured focal bias voltage value. 5. Second calibration point: a. Select SETUP/SETUP/2nd pt/CALIB on the X-ray Console; press the Exposure button on the X-ray Console (no X-rays are produced) and hold it until the voltmeter reading stabilizes. b. Note the focal bias voltage value measured from the voltmeter; release the Exposure button . c. Select SETUP/MEASV on the X-ray Console. d. Enter and confirm the measured focal bias voltage value. 6. Third calibration point: Page no. 1657 JC-CAL-A-003.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A003 - X-Ray Tube Focal Bias Voltage Scale Factor a. Select SETUP/SETUP/3rd pt/CALIB on the X-ray Console; press the Exposure button on the X-ray Console (no X-rays are produced) and hold it until the voltmeter reading stabilizes. b. Note the focal bias voltage value measured from the voltmeter; release the Exposure button . c. Select SETUP/MEASV on the X-ray Console. d. Enter and confirm the measured focal bias voltage value. 7. Fourth calibration point: a. Select SETUP/SETUP/4th pt/CALIB on the X-ray Console; press the Exposure button on the X-ray Console (no X-rays are produced) and hold it until the voltmeter reading stabilizes. b. Note the focal bias voltage value measured from the voltmeter; release the Exposure button . c. Select SETUP/MEASV on the X-ray Console. d. Enter and confirm the measured focal bias voltage value. 8. Select SETUP/SETUP/CALCUL/VALID on the X-ray Console. This calculates the parameters K, L, M and N. The message CALCUL DONE appears on the X-ray Console display. 9. Press SETUP/SETUP/SETUP/SETUP/SETUP/SETUP/CKSUM/CKSUM on the X-ray Console to perform a checksum. 6-4 Calibration Accuracy Check 1. 2. 3. 4. Shut down the Senographe system from the Browser. Re-connect flat cable WG8 to the Generator Command Board 400-PL1 connector XJ7. Power on the Senographe system from the X-ray Console. First check point: a. Select SETUP/GENE/INSTAL/GENE/GENE/BIAS/VOLTAGE/CHANGE on the X-ray Console and note the actual value associated to the tube (see step 3 section 6-2); b. Enter 3.000E+1V and valid. c. Press SETUP/SETUP/SETUP/SETUP/CKSUM/CKSUM on the X-ray Console to perform a checksum. d. Press SETUP/SETUP/SETUP/SETUP (i.e. 4 times) on the X-ray Console. e. Select 30kV/LARGE/MO/MO on the X-Ray Console. f. Do a preparation with the Prep button on the X-ray Console. g. Check that the result is between 28 and 32Vdc. 5. Second check point: a. Select SETUP/GENE/INSTAL/GENE/GENE/BIAS/VOLTAGE/CHANGE on the X-ray Console. b. Enter 7.000E+1V and valid. c. Press SETUP/SETUP/SETUP/SETUP/CKSUM/CKSUM on the X-ray Console to perform a checksum. d. Press SETUP/SETUP/SETUP/SETUP (i.e. 4 times) on the X-ray Console. e. Select 30kV/LARGE/MO/MO on the X-ray Console. f. Do a preparation with the Prep button on the X-ray Console. g. Check that the result is between 67 and 73Vdc. 6. Third check point: Chapter 9 Page no. 1658 JC-CAL-A-003.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A003 - X-Ray Tube Focal Bias Voltage Scale Factor a. Select SETUP/GENE/INSTAL/GENE/GENE/BIAS/VOLTAGE/CHANGE on the X-ray Console. b. Enter 1.300E+2V and valid. c. Press SETUP/SETUP/SETUP/SETUP/CKSUM/CKSUM on the X-ray Console to perform a checksum. d. Press SETUP/SETUP/SETUP/SETUP (i.e. 4 times) on the X-ray Console. e. Select 30kV/LARGE/MO/MO on the X-ray Console. f. Do a preparation with the Prep button on the X-ray Console. g. Check that the result is between 123.5 and 136.5Vdc. h. Select SETUP/GENE/INSTAL/GENE/GENE/BIAS/VOLTAGE/CHANGE on the X-ray Console and enter the value corresponding to the MO/LF noted in the first check point. 7. Fourth check point: a. Select MO/SF voltage parameter and note the actual value associated to the tube (see step 3 section 6-2). b. Enter 2.500E+2V and valid. c. Press SETUP/SETUP/SETUP/SETUP/CKSUM/CKSUM on the X-ray Console to perform a checksum. d. Press SETUP/SETUP/SETUP/SETUP (i.e. 4 times) on the X-ray Console. e. Select 30kV/SF/MO/MO on the X-ray Console. f. Do a preparation with the Prep button on the X-ray Console. g. Check that the result is between 247 and 256Vdc. 8. Fifth check point: a. Select SETUP/GENE/INSTAL/GENE/GENE/BIAS/VOLTAGE/CHANGE on the X-ray Console and enter the value corresponding to the MO/SF noted down on step 7 (fourth check point). b. Select MO/SF voltage parameter and note the default value. c. Enter 3.000E+2V and valid. d. Press SETUP/SETUP/SETUP/SETUP/CKSUM/CKSUM on the X-ray Console to perform a checksum. e. Press SETUP/SETUP/SETUP/SETUP (i.e. 4 times) on the X-ray Console. f. Select 30kV/SF/MO/MO on the X-ray Console. g. Do a preparation with the Prep button on the X-ray Console. h. Check that the result is between 297 and 305Vdc. i. Select SETUP/GENE/INSTAL/GENE/GENE/BIAS/VOLTAGE on the X-ray Console and select MO/SF. j. Enter the value corresponding to the MO/SF value noted down on step 7 (fourth check point). 9. If the results are within the tolerances given, the focal bias voltage calibration is finished. If the results are out of tolerance, repeat the calibration and check procedures. 10. Select SETUP/SETUP/SETUP/CALIB/PARAM on the X-ray Console. Note down the calculated values of parameters I, J, K, L, M and N. Each of these six values can be displayed alternately by rotating the kV dial on the X-ray Console, 11. Delete the previously created patient called "X-ray Tube BIAS cal". 12. Perform a checksum (SETUP/GENE/INSTAL/CKSUM/CKSUM), then turn the system OFF. 13. Remove the high voltage cable adapter. Remember to secure the HV ring correctly using the allen Page no. 1659 JC-CAL-A-003.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A003 - X-Ray Tube Focal Bias Voltage Scale Factor screw, to ensure proper ground continuity. 7 COMPLETION If you are handing the machine back to the user at this point, switch the Senographe off, then on again. Chapter 9 Page no. 1660 JC-CAL-A-003.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A007 - Automatic X-ray Tube Warm-Up Job Card CAL A007 - Automatic X-ray Tube Warm-Up 1 Chapter 9 SUPPLIES None 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 27 minutes 4 SAFETY PRECAUTIONS CAUTION These procedures produce X-rays. Be sure to take appropriate precautions. 5 PREREQUISITES This procedure should only be used when excessive arcing has made it impossible to carry out the procedure described in Job Card CAL A012 - X-Ray Tube Heater Current on page 1673. 6 PROCEDURE This procedure is to be used for re-starting an X-ray tube which was known to be good upon leaving the factory, but now exhibits arcing after a long period of inactivity. The principle is to take a series of 12 pre-determined exposures, starting at low kV values and progressively increasing towards high kV values. If arcing occurs during an exposure, some or all exposures are automatically repeated. If persistent arcing occurs, the warm-up procedure is automatically terminated. Proceed as follows: 1. Select SETUP/GENE/INSTAL/GENE/GENE/TUBE/WarmUp on the X-ray Console. The track/kV combination for the first exposure should appear on the X-ray Console display. 2. Press the Exposure button taken. on the X-ray Console and HOLD IT DOWN while the exposures are Note: There is a time delay of 10 seconds between exposures. You can release the Exposure button during this 10 second period, then press it again to continue, but the minimum time between exposures will still be 10 seconds. If the tube overheats at some point, exposures will be inhibited until it cools down again. During the cooling period, the Exposure button can be released; as soon as the display shows that the X-ray tube has sufficiently cooled, press the Exposure button to continue. 3. When the warm-up procedure is finished, the message Tube OK normally appears on the X-ray Console display. If persistent arcing occurred during the procedures, the message Too many spits appears on the X-ray Console display. Page no. 1661 JC-CAL-A-007.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A007 - Automatic X-ray Tube Warm-Up This page is blank. Chapter 9 Page no. 1662 JC-CAL-A-007.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A009 - X-Ray Tube mA Measurement Job Card CAL A009 - X-Ray Tube mA Measurement 1 Chapter 9 SUPPLIES None 2 • TOOLS Meter for measurement of mA. The meter must be in good condition and possess valid certification. Suitable meters are: - Fluke 87 multimeter - Keithley 35035 mAs meter - GS Poner 165 mA-mAs meter 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 27 minutes 4 SAFETY PRECAUTIONS None 5 PREREQUISITES None 6 CALIBRATION OF X-RAY TUBE MA MEASUREMENT The objective is to determine the scale factor F/mA between the X-ray tube mA measurement input to the software and the real X-ray tube mA value. The default parameter value is F/mA = +1.000E+3 (1000) Hz/mA CAUTION DO NOT touch potentiometer P1 on generator kV/mA board 701-PL1 at any point in this procedure. Page no. 1663 JC-CAL-A-009.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A009 - X-Ray Tube mA Measurement 6-1 Preparation 1. Turn off the Senographe. 2. Remove strap between terminal lugs MES_M_NEG and MES_M_POS of generator kV/mA board 701-PL1. MES_M_NEG Strap MES_M_POS 3. Connect the milliammeter between test points MES_M_NEG and MES_M_POS of generator kV/mA board 701-PL1. Set the milliammeter to its 100 mA DC scale. 4. Turn on the Senographe. Chapter 9 Page no. 1664 JC-CAL-A-009.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A009 - X-Ray Tube mA Measurement 6-2 Perform the calibration procedure 1. Starting from application mode, select SETUP/GENE/INSTAL/GENE/GENE/mA_meas/CALIB/ CALIB on the X-ray Console. Press push button SW2 on generator kV/mA board 701-PL1 and HOLD IT DOWN. Read and note down the value measured on the milliammeter. While still holding SW2 down, select MEASUR on the X-ray Console (this request for a measurement of X-ray tube current is needed by the calibration software, but the value displayed on the X-ray Console at this point is of no importance to the service engineer). Release push button SW2. 2. Select SETUP/I_MEAS on the X-ray Console. Enter the value of current (in milliamperes) read from the milliammeter by using the NEXT and VALID keys and rotating the kV dial. See Visual Display of Parameter Values and Modification of a Parameter Value or Entry of a Measurement in Job Card CFG "The X-ray Console". Note: Only values between +4.000E+1 (40) and +6.000E+1 (60) mA are accepted by the calibration software. An error message appears on the X-ray Console display if a value outside of this range is entered. 3. Select SETUP/CALCUL/VALID on the X-ray Console to execute the calculation. If the calculated F/ mA value is between 850 and 1150 mA calib END appears on the X-ray Console display - if it is not, then an error message appears. 6-3 Check results 1. Select SETUP/CALIB on the X-ray Console. Press push button SW2 on generator kV/mA board 701PL1 and HOLD IT DOWN. Read and note down the value measured on the milliammeter. While still holding SW2 down, select MEASUR on the X-ray Console. Verify that the measurement on the X-ray Console display now corresponds to the value read on the milliammeter ±400 µA ± milliammeter error. Release push button SW2. DO NOT ENTER THIS MEASURED VALUE. 2. Change the milliammeter scale to 200 mA DC. Press push button SW1 on generator kV/mA board 701-PL1 and HOLD IT DOWN. Read and note down the value measured on the milliammeter (the current should be approximately 120 mA). While still holding SW1 down, select MEASUR on the Xray Console. Verify that the difference between the measurement on the X-ray Console display and the value read on the milliammeter is less than 2.4 mA. Release push button SW1. DO NOT ENTER THIS MEASURED VALUE. 3. Select SETUP/SETUP/PARAM on the X-ray Console and note down the displayed value of F/mA. 4. Perform a checksum (SETUP/SETUP/SETUP/SETUP/CKSUM/CKSUM) and return to Application mode. 5. Turn off the Senographe. 6. Disconnect the milliammeter and replace the strap between terminal lugs MES_M_NEG and MES_M_POS of generator kV/mA board 701-PL1. 7 COMPLETION If you are handing the machine back to the user at this point, switch the Senographe off, then on again. Page no. 1665 JC-CAL-A-009.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A009 - X-Ray Tube mA Measurement This page is blank. Chapter 9 Page no. 1666 JC-CAL-A-009.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A011 - Calibration of kV Scale Factor Job Card CAL A011 - Calibration of kV Scale Factor 1 Chapter 9 SUPPLIES None 2 • TOOLS kVp meter. The kVp meter must be in good condition and possess valid certification. Suitable meters are: - Radcal 4083 kVp meter (requires use of acrylic plates) - RMI 232 kVp meter - Keithley 35080B kVp meter Note: The calibration curve attached to the meter (obtained during periodic recalibration of the meter) must be used to correct the meter reading throughout this procedure. Note: The Keithley 35080B kVp meter is not recommended for use in Europe It does not meet the European accuracy requirement of 3%. • Standard 19 X 23 Compression Paddle for positioning the kVp meter close to the Tube Head • Detector Protection Plate (used to protect the detector from the possibility of falling objects) • Radiation Protection Plate (used to protect the detector from excessive exposure to X-rays) 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS The procedures in this Job Card produce X-rays. Ensure that you take appropriate precautions when operating with X-rays (for example, stay behind the radiation screen during an X-ray exposure). 5 PREREQUISITES None 6 CALIBRATION OF KV SCALE FACTOR The objective is to determine the scale factor G and offset VOF between the X-ray tube kV command from the software and the real kV value obtained. DEFAULT PARAMETER VALUES ARE G = +6.554E+1 (65.54) and VOF = +0.000E+0 (0.0) CAUTION DO NOT touch potentiometer P1 on generator kV/mA board 701-PL1 at any point in this Procedure. Page no. 1667 JC-CAL-A-011.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A011 - Calibration of kV Scale Factor 6-1 Preparation 1. Use adhesive tape (or similar) (1) to attach the Radiation Protection Plate (2) to the bottom side of the Standard 19 x 23 Compression Paddle as shown below. 1 2 Note: Ensure the adhesive tape is attached in such a way that when it is removed, it will not leave glue residue on the Compression Paddle. ! Notice: The Radiation Protection Plate will protect the detector from excessive exposure to X-rays. Before proceeding to make exposures, ensure that the detector has been protected from excessive X–ray doses as instructed above. 2. Remove the Bucky, and install the Detector Protection Plate (3) on the detector. 3. Install the Standard 19 x 23 Compression Paddle updside down, so that the Radiation Protection Plate is approximately below the bottom of the Tube Head as follows: • 205 mm (8.07 inches) for the RMI 232 kVp meter and Keithley 35080B kVp meter • 155 mm (6.10 inches) for the Radcal 4083 kVp meter 205 mm for RMI 232 and Keithley 35080B 155 mm for Radcal 4083 4 Chapter 9 Page no. 1668 JC-CAL-A-011.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A011 - Calibration of kV Scale Factor The purpose here is simply to reduce the distance between the kV peak meter and the X-ray source - see applicable documentation for minimum acceptable distance from X-ray source, if any. 4. Place the kV peak meter on the Radiation Protection Plate located on the Standard 19 X 23 Compression Paddle. Turn it on and set it to the MO/MO position. Set the waveform selector to CP (constant potential), for RadCal 4082 turn it by using the "Normal" button. 5. Use the Senographe light centering device to center the kV peak meter target with the X-ray zone. 6. Select manual exposure mode, and set the X-ray parameters to: Mo track/Mo filter, 50 mAs, LF 6-2 Perform the calibration procedure 1. Select SETUP/GENE/INSTAL/GENE/GENE/KV/CALIB/1st pt/CALIB on the X-ray Console. Note: By default, the kV command value sent by the software for this 1st point is 25 kV. 2. Press the Exposure button on the X-ray Console and hold it down. A single 1-second exposure is taken. CALIBRATION END appears on the X-ray Console display. Release the Exposure button Note down the kV value displayed on the kV peak meter. . Note: If for some reason this exposure has to be repeated, select SETUP/CALIB on the X-ray Console before pressing the Exposure button again. 3. Select SETUP/kV_M on the X-ray Console. Enter the kV value read from the kV peak meter by using the NEXT and VALID keys and rotating the kV dial. If necessary (for example with the RMI 232 vVp meter) remember to apply the kV correction value from the meter’s calibration curve to the value displayed on the kVp meter. For more information on specifying numeric values on the X-ray Console refer to Representation of Numeric Parameters on page 96. Page no. 1669 JC-CAL-A-011.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A011 - Calibration of kV Scale Factor 4. Select SETUP/SETUP/2nd pt/CALIB on the X-ray Console. Note: By default, the kV command value sent by the software for this 2nd point is 40 kV. Due to Senographe software, the Mo filter remains selected. 5. Press the Exposure button on the X-ray Console and hold it down. A single 1-second exposure is taken. CALIBRATION END appears on the X-ray Console display. Release the Exposure button Note down the kV value displayed on the kV peak meter. . Note: If for some reason this exposure has to be repeated, select SETUP/CALIB on the X-ray Console before pressing the Exposure button again. 6. Select SETUP/kV_M on the X-ray Console. Enter the kV value read from the kV peak meter by using the NEXT and VALID keys and rotating the kV dial. If necessary (for example with the RMI 232 vVp meter) remember to apply the kV correction value from the meter’s calibration curve to the value displayed on the kVp meter. For more information on specifying numeric values on the X-ray Console refer to Representation of Numeric Parameters on page 96. 7. Select SETUP/SETUP/calcul/VALID on the X-ray Console to execute the calculation. Normally, KV CALIB END appears on the X-ray Console display. The message OUT OF RANGE on the X-ray Console display indicates either faulty kV measurement(s) in the steps above, or a hardware failure. 6-3 Check results 1. Remove the kV peak meter, Radiation Protection Plate, Detector Protection Plate, and Standard 19 X 23 Compression Paddle. Note: When removing the adhesive tape from the Radiation Protection Plate and Standard 19 X 23 Compression Paddle take care not to leave glue residue on the Compression Paddle and Radition Protection Plate. 2. Install the Bucky. 3. Place some paper on the Bucky (to protect it) and place the Radiation Protection Plate on the Bucky. This will protect the detector from excessive exposure to X-rays. ! Notice: Before proceeding to make exposures, ensure that the detector has been protected from excessive X–ray doses as instructed (by placing a Radiation Protection Plate on the top of the Bucky). 4. Place the kV peak meter on the Bucky. Turn it on and set it to the MO/MO position. Set the waveform selector to CP (constant potential), for RadCal 4082 turn it by using the "Normal" button. 5. Use the Senographe light centering device to center the kV peak meter target with the X-ray zone. Chapter 9 Page no. 1670 JC-CAL-A-011.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A011 - Calibration of kV Scale Factor 6. Select SETUP/1st pt/CALIB on the X-ray Console. 7. Press the Exposure button on the X-ray Console and hold it down. A single 1-second exposure is taken.”CALIBRATION END” appears on the X-ray Console display. Release the Exposure button . Note down the kV value displayed on the kV peak meter. DO NOT ENTER THIS MEASURED VALUE. 8. The kV value read on the kV peak meter should be 25 kV ± 0.3 kV. Note: The generator kVp accuracy is ±1% (one per cent) when measured just after a calibration. 9. Select SETUP/SETUP/2nd pt/CALIB on the X-ray Console. ! Notice: Before proceeding to make exposures, be sure that the detector has been protected from excessive X–ray doses as instructed (by placing a protective sheet on the top of the image receptor). 10. Press the Exposure button on the X-ray Console and hold it down. A single 1-second exposure is taken. The message CALIBRATION END appears on the X-ray Console display. Release the Exposure button . Note down the kV value displayed on the kV peak meter. DO NOT ENTER THIS MEASURED VALUE. 11. The kV value read on the RMI kV peak meter should be 40 kV ± 0.4 kV. Note: The generator kVp accuracy is ±1% (one per cent) when measured just after a calibration. Note: If the need should arise to check this point in application mode, it is not possible to do so because exposures at 40 kV are prohibited with the Mo filter in application mode. 12. Select SETUP/SETUP/SETUP/PARAM on the X-ray Console. Note down the displayed values of G and VOF by rotating the kV dial. 13. Perform a checksum (SETUP/SETUP/SETUP/SETUP/CKSUM/CKSUM) and return to Application mode. 7 COMPLETION If you are handing the machine back to the user at this point, switch the Senographe off, then on again. Page no. 1671 JC-CAL-A-011.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A011 - Calibration of kV Scale Factor This page is blank. Chapter 9 Page no. 1672 JC-CAL-A-011.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A012 - X-Ray Tube Heater Current Job Card CAL A012 - X-Ray Tube Heater Current 1 Chapter 9 SUPPLIES None 2 TOOLS • • Detector Protection Plate Mag Stand (or Magstand simulator) • • Set of acrylic plates Meter for measurement of mA. The meter must be in good condition and possess valid certification. Suitable meters are: - Fluke 87 multimeter - Keithley 35035 mAs meter - GS Poner 165 mA-mAs meter 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 40 minutes 4 SAFETY PRECAUTIONS The procedures in this Job Card produce X-rays. Ensure that you take appropriate precautions when operating with X-rays (for example, stay behind the radiation screen during an X-ray exposure). 5 PREREQUISITES The Generator covers must be removed for access to the kV/mA board 701-PL1 on the HV tank unit. Refer to Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513. 6 CALIBRATION OF X-RAY TUBE HEATER CURRENT The objective is to determine the X-ray tube heater current required to produce the desired X-ray tube anode current at a given kV value. The calibration procedure must be performed on each of the four focal size/track combinations. Four repetitions of the calibration procedure are therefore necessary. Three exposures are taken automatically at different kV values. Using the results, the software calculates the necessary parameters to determine the X-ray tube heater current needed to produce the desired X-ray tube anode current for all possible kV values. ! Notice: In some situations, usually after a tube has been unused for a long period, excessive arcing may make it impossible to carry out the procedures described in this Job Card. A warm-up procedure to correct the problem is described in Job Card CAL A007 - Automatic X-ray Tube Warm-Up on page 1661. Page no. 1673 JC-CAL-A-012.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A012 - X-Ray Tube Heater Current 6-1 • Preparation Place the Detector Protection Plate on the top of the image receptor to protect the detector panel from excessive X-ray doses. 6-2 Calibration procedure 1. From the X-ray Console, select: SETUP/GENE/INSTAL/GENE/GENE/TUBE/HEATER/focal size/ track/CALIB. Perform the calibration procedure first on the LF/MO focal size/track combination. CAUTION Before proceeding to make exposures, be sure that the detector panel has been protected from excessive X–ray doses as instructed (by placing a steel cover on the image receptor). 2. Press the Exposure button on the X-ray Console and hold it down. The messages EXPOSURE NO 1, EXPOSURE NO 2, EXPOSURE NO 3, and CALIBRATION END appear in sequence on the Xray Console display. The software automatically performs the three exposures and the calculations. Note: - Calibration time varies according to tube temperature. The message TOO WARM appears on the X-ray Console display when tube temperature is too high for taking the next exposure. It is not necessary to hold the Exposure button down while waiting for the tube to cool. However, do not exit the calibration menu while waiting. As soon as the TOO WARM message disappears, continue the calibration by pressing and holding the Exposure button . - In case of arcing, the software re-attempts the same exposure automatically. - The calibration procedure includes an exposure at 40 kV. If for some reason this exposure is impossible to perform (e.g. excessive arcing), tube warm-up may be necessary. 3. Repeat steps 1 and 2 for LF/Rh. 4. Perform a checksum (SETUP/SETUP/SETUP/SETUP/SETUP/SETUP/CKSUM/CKSUM). 5. Exit the Calibration Menu (SETUP/SETUP/SETUP/SETUP/SETUP). 6. Plug in the Mag Stand or the Magstand Simulator to automatically select the small focus. Note: Do not select the small focus from the X-ray Console. Doing so will cause an "out of order" message. Note: Even if the Senographe system is not delivered with the Mag Stands, you must still perform all of the Small Focus (Mag Mode) calibrations listed below. This is because the Magnification Option Installation Manual does not include a Job Card to perform the calibration of the X-ray Tube Heater Current in Mag Mode. 7. Repeat steps 1 and 2 for SF/Mo. 8. Repeat steps 1 and 2 for SF/Rh. 9. Perform a checksum (SETUP/SETUP/SETUP/SETUP/SETUP/SETUP/CKSUM/CKSUM). 10. Exit the Calibration Menu (SETUP/SETUP/SETUP/SETUP/SETUP). 11. Carry out the following steps only if the warning message Limited Ich (limited heater current) appears on the X-ray Console at the end of the tube current calibration. This message indicates that one or more filament heating current values were calculated above 5.6 A (but internally limited to 5.600 A when stored in memory). The message is only a warning and is not associated with an error code. Proceed as follows: Chapter 9 Page no. 1674 JC-CAL-A-012.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A012 - X-Ray Tube Heater Current a. Access the Senographe installation menu to read the heater parameters with the LF/MO combination (select SETUP/GENE/INSTAL/GENE/GENE/TUBE/HEATER/LF/MO/Param/I-Value). b. Explore the 28 kV/A combinations; note the kV values showing a current value equal to 5.600 A. c. Repeat steps a and b for the LF/RH combination (there is a very low probability of current limitation occurring in small focus). d. Return to Application Mode (press SETUP). e. Set the Senographe for 2-point exposure technique at 60 mAs. Make an exposure for each kV point detected at 5.600 A (LF/MO and LF/RH). Allow at least 60 seconds between each exposure. f. Repeat steps a and b: If no more kV points are set to 5.600 A, the problem has been resolved. If one or more points still show a current value of 5.600 A, repeat Calibration Job Card Heater Current Scale Factor, then restart this procedure from step a above. If the problem recurs, replace the X-ray tube. Note: If the automatic calibration fails and you recieve arching errors for the LF/Mo calibration point, calibration can be done manually. Refer to Trouble Shooting on page 1675. 6-3 Check results 1. Be sure that the Gantry presence parameters PRS_B, PRS_DS, and PRS_IDC are set to yes before proceeding. 2. Refer to Job Card CHK A013 - Check mA and mAs settings. Perform sections 6-1 Preparation on page 1756 and 6-3 Check mA calibration on page 1757. 6-4 Completion If you are handing the machine back to the user at this point, switch the Senographe off, then on again. 7 TROUBLE SHOOTING You may obtain the message arcing for the last LF/Mo calibration point. In most cases, the tube does not actually arc. The main cause of the problem is the high mA value seen by the Generator as an electrical arc in the tube. On some tubes with very good cold-to-hot emission (usually seen on mature tubes), the reason for this high mA value is the excessively high filament heating starting current I HEATER set as default in the software. This problem can appear when calibrating the Large Focal/Mo Track. The LF/Mo combination requires the highest mA for the tube (up to 100 mA for 30 kV). For some kV values (see Table 1 on page 1677), the filament starting value I HEATER is set too high, leading to mA overshoot. In fact, when performing this Job Card, the real filament starting value I HEATER required by the tube in normal operation is lower than the default value. Note: The default values cannot be changed except with a new software version. It is therefore necessary to update the filament starting value I HEATER manually for each kV station in Application Mode. In Application Mode, the I HEATER parameters are continually updated after each e posure greater than 500 ms, and with an I HEATER value limited to +/–2% of the previous value. If the message arcing is displayed for the combination LF/Mo, proceed with the following solution: Page no. 1675 JC-CAL-A-012.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A012 - X-Ray Tube Heater Current 1. Perform section 6-2, Calibration procedure on page 1674 for the LF/Rh, SF/Mo and SF/Rh combinations, but not the LF/Mo combination. 2. For the combination LF/Mo in the Generator software table; manually enter a low I HEATER value equal to +4.500E+0 A for each kV station. From Application Mode, the complete path is: SETUP / GENE / INSTAL /GENE / GENE / TUBE / HEATER / LF/Mo / PARAM / I_VALUE / CHANGE. Press , then enter using the Next and Valid keys and the kV dial. Once the value is entered and confirmed, press to continue entering the remaining parameter values for each kV station. 3. Set the Senographe configuration to display the I HEATER value measured after each exposure. From Application Mode the complete path is: SETUP / GENE / INSTAL / GENE / CONFIG / DISP / YES. Following an exposure, some parameters are displayed in two groups which appear alternately; I HEATER measured is the last item in the first group. 4. Return to manual Application Mode (two points) with the combination LF/Mo (any filter). 5. To confirm the I HEATER value measured, an exposure time longer than 500 ms is required. To ensure this minimum time, select 63 mAs for all kV stations. Perform an exposure for each kV station, and record the displayed value of the corresponding I HEATER LF/MO in Table 2 on page 1678. Note: Wait at least 30 seconds between exposures to avoid obtaining a TUBE TOO HOT message. Verify that all the values noted in the table are in descending order (starting from 22 kV); in the event of discrepancy, perform a second exposure for verification. 6. Enter in the Generator software table all the I HEATER LF/MO measured using the same path and procedure as in step 2 within this solution. Note: The last digit of the value entered is normally decreased by 1. 7. Check the results by referring to section 6-3, Check results on page 1675. 8. If you are handing the machine back to the user at this point, switch the Senographe off, then on again. Chapter 9 Page no. 1676 JC-CAL-A-012.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A012 - X-Ray Tube Heater Current TABLE 1 - DEFAULT HEATING CURRENT PARAMETERS LF/Mo kV SF/Mo SF/RH Amperes 22 5.19 4.71 4.87 4.67 23 5.16 4.73 4.87 4.68 24 5.14 4.75 4.88 4.69 25 5.13 4.77 4.88 4.70 26 5.13 4.79 4.88 4.72 27 5.12 4.81 4.88 4.74 28 5.12 4.82 4.88 4.76 29 5.12 4.83 4.89 4.78 30 5.11 4.84 4.89 4.79 31 5.08 4.81 4.87 4.76 32 5.06 4.78 4.84 4.74 33 5.01 4.75 4.82 4.71 34 4.99 4.73 4.80 4.68 35 4.96 4.71 4.78 4.66 36 4.94 4.68 4.76 4.64 37 4.92 4.66 4.74 4.62 38 4.90 4.64 4.73 4.60 39 4.88 4.62 4.72 4.59 40 4.86 4.61 4.70 4.57 41 4.84 4.59 4.69 4.56 42 4.83 4.58 4.67 4.55 43 4.82 4.56 4.66 4.53 44 4.80 4.55 4.65 4.52 45 4.79 4.53 4.63 4.50 46 4.77 4.52 4.62 4.49 47 4.76 4.51 4.61 4.48 48 4.74 4.50 4.60 4.47 49 4.73 4.49 4.59 4.45 Page no. 1677 JC-CAL-A-012.fm LF/RH Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A012 - X-Ray Tube Heater Current TABLE 2 - I HEATER FOR LF/MO COMBINATION Chapter 9 kV I HEATER LF/Mo 22 4.5 23 4.5 24 4.5 25 4.5 26 4.5 27 4.5 28 4.5 29 4.5 30 4.5 31 4.5 32 4.5 33 4.5 34 4.5 35 4.5 36 4.5 37 4.5 38 4.5 39 4.5 40 4.5 41 4.5 42 4.5 43 4.5 44 4.5 45 4.5 46 4.5 47 4.5 48 4.5 49 4.5 I HEATER LF/Mo from extended display after 63 mAs exposure Page no. 1678 JC-CAL-A-012.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A021 - Arm Rotation Calibration Job Card CAL A021 - Arm Rotation Calibration 1 Chapter 9 SUPPLIES None 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 20 minutes 4 SAFETY PRECAUTIONS None 5 PREREQUISITES None 6 PROCEDURE Note: The compression arm angle must be calibrated to allow automatic selection of view names. Note: The sign convention for Senographe applications is illustrated here, shown looking at the tube head or chest wall of the Senographe. 0° + 6-1 • • • • 180° Principle Arm rotation travel limits are factory set; However, if parts have been replaced or disturbed which affect the software or hardware limits, calibration must be carried out. Calibration is necessary to set travel limits in software, defining the maximum positive and negative usable angles. - The procedure first calibrates the 0° position to establish a reference point for the measurement system (potentiometer and encoder). - Travel limits are then set at the 185° and -165° positions Optical sensors ("optical forks") are used to recognize and stop any movement beyond the software limits, before impact with mechanical stops. 6-2 • • - Calibration procedure Move the lift to a height which will allow rotation of the arm between 185° and -165°. Select the Rotation Calibration on the ADS LCD screen: Service Desktop/Calibration/Positioner/ Rotation. You are asked to follow the instructions displayed on the Gantry readout: Page no. 1679 JC-CAL-A-021.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A021 - Arm Rotation Calibration 6-2-1 Set the 0° position 1. You are asked to move the arm to the 0° position. Press and hold the appropriate rotation movement control button. Stop the arm at the 0° position. 2. Check that the arm is in the correct position (0° ±0.5°) by using a spirit level or similar device to check that the top of the digital detector is horizontal. 3. If necessary, use the movement control buttons to adjust the arm as required until it is in the 0° position. 4. When the arm has been correctly positioned, press the collimator FOV size button (behind the tube head) to signal completion of the 0° adjustment. 6-2-2 Set the 185° position 1. You are now asked to move the arm to the 185° position. Press and hold the appropriate rotation movement control button to rotate the arm counter-clockwise until it stops. 2. Check that the arm is in the correct position (185° ±0.5°) by using a spirit level and a suitable angle measuring device to check that the top of the digital detector (now pointing down) is at 5° from the horizontal. 3. If necessary, use the movement control buttons to adjust the arm as required until it is in the 185° position. 4. When the arm has been correctly positioned, press the collimator FOV size button (behind the tube head) to signal completion of the 185° adjustment. 5. If the 185° position cannot be attained, or the message on the Gantry readout indicates an error, repeat the procedures to set the 0° and 185° positions. If the problem persists, it will be necessary to investigate for a hardware error. 6-2-3 Set the -165° position 1. You are now asked to move the arm to the -165° position. Press and hold the appropriate rotation movement control button to rotate the arm clockwise until it stops. 2. Check that the arm is in the correct position (-165° ±0.5°) by using a spirit level and a suitable angle measuring device to check that the top of the digital detector (now pointing down) is at 15° from the horizontal. 3. If necessary, use the movement control buttons to adjust the arm as required until it is in the -165° position. 4. When the arm has been correctly positioned, press the collimator FOV size button (behind the tube head) to signal completion of the -165° adjustment. 5. If the -165° position cannot be attained, or the message on the Gantry readout indicates an error, repeat the procedures to set the 0°, 185° and -165° positions. If the problem persists, it will be necessary to investigate for a hardware error. 6-2-4 Completion • If the calibration has been successfully completed, save the results by clicking the Save button on the AWS Screen. • If you wish to exit the calibration without saving the results (leaving the system un-calibrated or using the previous settings), click the Cancel button on the AWS Screen. Chapter 9 Page no. 1680 JC-CAL-A-021.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A027 - Tube Tilt Calibration Job Card CAL A027 - Tube Tilt Calibration 1 Chapter 9 SUPPLIES None 2 TOOLS Magstand simulator, included in the Seno. DS Emergency kit. 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 20 minutes 4 SAFETY PRECAUTIONS The procedures in this Job Card produce X-rays. Ensure that you take appropriate precautions when operating with X-rays (for example, stay behind the radiation screen during an X-ray exposure). 5 • PREREQUISITES All detector calibrations must have been cleared (select Service desktop/Calibration/Detector; then select Clear Calibrations and perform the clear procedure as indicated on the screen). 6 CALIBRATION OF X-RAY TUBE TILT 6-1 Introduction The objective is to evaluate the difference between the real and the theoretical tilt angle. The real tilt angle depends on mechanical properties (position of the optical fork, tube and others). The difference can be measured by a specific exposure. After the exposure the ADS receives an image and returns the distance from the chest wall to the anode heel. The real tilt angle can be determined from this distance: Real tilt angle = arctan [ Chest wall to anode heel distance (mm) Source-Image Distance (mm) ] Source-Image Distance = 660 mm ! Notice: DO NOT perform Tube Tilt Calibration unless it is strictly necessary (e.g., after tube replacement or when there is clear evidence of bad calibration parameters). BEFORE performing Tube Tilt Calibration, clear all detector calibrations (select Service desktop/Calibration/Detector; then select Clear Calibrations and perform the clear procedure as indicated on the screen). Page no. 1681 JC-CAL-A-027.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A027 - Tube Tilt Calibration 6-2 Procedure Note: If for any reason it is necessary to power OFF during the calibration procedure, you must power OFF the whole system by using the Power OFF button on the X-ray Console. 1. From the Browser, launch the Service Desktop (see Launching the Service Desktop on page 120). 2. 3. 4. 5. 6. 7. From the Service Desktop, click the Calibration button . Select System/Tube Tilt. Remove the Bucky, the compression paddle and any other objects from the field of view. Install the Magstand simulator plug. Click on START; make an exposure. Wait for the result of the calibration. The calculated real tilt angle appears, together with the chest wall to anode heel distance (for information only). The real tilt angle must be 13.5°±0.5°. 8. Take the appropriate action: - If the result is within the specified tolerance, click SAVE, The calibration is complete - If there is an error message, click Cancel, then follow the instructions on the screen and repeat the calibration. When the calibration is complete, the AWS screen automatically returns to the System Calibration menu. 7 COMPLETION If you are handing the machine back to the user at this point, power off the whole system from the X-ray Console, then on again. Chapter 9 Page no. 1682 JC-CAL-A-027.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A029 - Collimator Format Calibration Job Card CAL A029 - Collimator Format Calibration 1 Chapter 9 SUPPLIES None 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS The procedures in this Job Card produce X-rays. Ensure that you take appropriate precautions when operating with X-rays (for example, stay behind the radiation screen during an X-ray exposure). 5 PREREQUISITES Job Card CAL A027 - Tube Tilt Calibration on page 1681 must have been completed. 6 PROCEDURE 6-1 Objective The aim of collimator calibration is to ensure that X-ray field and receptor misalignment is within the regulatory specification. 6-2 Front blade alignment and blade parallelism check This part of the calibration is intended to align the front blade edge of the collimator with the detector edge at the chest wall side, and to check the blade parallelism. Note: If it is not possible to align the front blade edge with the detector chest wall edge, the blade parallelism check cannot be performed. Proceed as follows: 1. Select on AWS Screen: Service Desktop/Calibration/System/Collimator calibration. 2. Remove the Bucky, the compression paddle and any objects from the field of view. 3. Click the START button on the AWS Screen. 4. Use the X-ray Console to make the exposure. 5. Observe the front blade angle displayed on the screen. Select and perform the appropriate action as described in the following sections: Page no. 1683 JC-CAL-A-029.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A029 - Collimator Format Calibration 6-2-1 Displayed angle greater than 2 • Calibration is not possible. The collimator must be reinstalled and the calibration repeated: 1. Click the on-screen CANCEL button to terminate the calibration. 2. Remove and reinstall the collimator. 3. Restart the calibration as described above. 6-2-2 Displayed angle less than 2 but greater than 0.1 • The calibration is not correct, but adjustment should be possible. Proceed as follows (refer to the illustrations below): 1. Remove the two screws (1, one each side) securing the rear plate (2) which supports the FOV button (4 mm allen wrench). Remove the plate. 2. Release (but do not remove) the two front nuts (3) and two rear nuts (4) securing the collimator (7 mm open-ended wrench). 3. Release the locking screw (5) (5.5 mm open-ended wrench). 4. Turn the adjustment screw (6) at the back of the collimator according to the instructions on the screen. An indicator is provided on the screw to assist in accurate adjustment. 5. Tighten the locking screw (5). 6. Tighten the four securing nuts (3, 4). 7. Reinstall the rear plate (2) and its securing screws (1). 8. Click the CONTINUE button. The calibration steps are repeated. 4 5 6 3 1 2 Front view Up/down Rear view 6-2-3 Displayed angle less than 0.1 • The front blade edge is parallel to the detector chest wall edge within the specified limits. 1. Check the four blade angles displayed on the screen. They must be within the following limits: Displayed angle Minimum Maximum Front angle -0.5° 0.5° Right angle -0.5° 0.5° Rear angle -0.5° 0.5° Left angle -0.5° 0.5° 2. If all of the displayed angles are within the specified limits, the calibration is successful. Continue with section 6-3 below. 3. If any one of the displayed angles is outside these limits, the collimator must be changed. Chapter 9 Page no. 1684 JC-CAL-A-029.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A029 - Collimator Format Calibration 6-3 Offset computation When the front blade has been correctly calibrated, the blade offsets are calculated: 1. Click the CONTINUE button to continue with Offset Calibration 2. Use the X-ray Console to make two exposures. 3. The offset values for the four blades are displayed on screen. Check that they are within the following limits: Displayed offset Minimum Maximum Front blade offset -95 85 Right blade offset -70 70 Rear blade offset -53 no specified limit Left blade offset -70 70 4. If all of these offsets are within the specified limits, the calibration procedure is complete: click the SAVE button to store the offset values 5. If any one of the displayed values is out of specification, more checks and adjustments must be made. Continue with the corrective actions described in section 6-3-1 below. 6-3-1 Corrective actions If any one of the displayed values is out of specification, select the appropriate action as described below: 1. A displayed offset is out of specification at the first attempt. The collimator must be reinstalled and the full calibration procedure repeated. Proceed as follows: a. Click the on-screen CANCEL button to terminate the calibration. b. Remove and reinstall the collimator. c. Repeat the full calibration procedure from section 6-2. d. If the calibration of parallelism and computation of offset values are now within specifications, the calibration procedure is now complete. e. If one of the displayed values is still out of specification, continue with step 2. 2. A displayed offset is out of specification after reinstallation of the collimator. The action to be taken depends upon the blade offset in error. Proceed as follows: a. If the front or rear blade offset is out of specification, check the positions of the detector assembly and the tube assembly. If it is necessary to move either the tube or the detector, perform Job Card CAL A027 - Tube Tilt Calibration on page 1681. Then repeat the full collimator format calibration. b. If the left or right blade offset is out of specification, check the position of the tube assembly. If it is necessary to move the tube, perform Job Card CAL A027 - Tube Tilt Calibration on page 1681. Then repeat the full collimator format calibration. c. If one of the displayed values is still out of specification, continue with step 3. Page no. 1685 JC-CAL-A-029.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A029 - Collimator Format Calibration 3. A displayed offset is out of specification after reinstallation of the collimator and Tube Tilt Calibrations. The action to be taken depends upon the blade offset in error. Manually adjust the position of the collimator, as follows: a. Rotate the Arm to +180° so that the Tube Head is upside down. b. Loosen the collimator by loosening the collimator’s four screws (7). 7 c. Move the collimator according to the blade offset in error that you witnessed, as follows: If the rear blade offset is out of specification, pull the collimator towards the patient, and then tighten all of the four screws. If the right blade offset is out of specification, push the collimator fully towards the right. Then first tighten the screws the two screws on the right, and then tighten the two screws on the left. If the left blade offset is out of specification, push the collimator fully towards the left. Then first tighten the screws the two screws on the left, and then tighten the two screws on the right. d. Repeat the full calibration procedure from section 6-2. e. If one of the displayed values is still out of specification, continue with step 4. 4. A displayed offset is out of specification after reinstallation of the collimator, after detector and tube checks have been made, and after the manual collimator adjustments have been made. The collimator must be changed. Chapter 9 Page no. 1686 JC-CAL-A-029.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A031 - Lift Calibration Job Card CAL A031 - Lift Calibration 1 Chapter 9 SUPPLIES None 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 15 minutes 4 SAFETY PRECAUTION No specific safety precautions are applicable. 5 PREREQUISITES None 6 PROCEDURE 6-1 Principle The illustration below highlights the important principles behind calibrating the lift. Ceiling Key LE : Lift Encoder LP : Lift Potentiometer Upper lift travel limit Derived from the lift travel limit plus the lower lift travel limit 1 850 mm 750 mm Top 650 mm Middle Bottom Lower optical fork position (fixed) Floor 0 mm LE LP 670 ±2 mm Lift travel limit 4 Set in ADS software and must correspond to upper optical fork position Lift Potentiometer Upper Reference Voltage Set with FOV size button 650 mm — this automatic stop distance during the calibration phase is determined by the Lift Encoder which accurately translates lift screw turns to height travelled. Lower lift travel limit Measured then set Page no. 1687 JC-CAL-A-031.fm 3 Lift Board Firmware Upper optical fork position Lift Potentiometer Lower Reference Voltage 2 Set with FOV size button Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A031 - Lift Calibration The numbered circles 1, 2, 3 and 4 correspond to the procedural sections within this Job Card as follows: 1. 6-2-1, Upper Optical Fork Positioning (if the ceiling height has changed in the room) 2. 6-2-2, Lower Limit Adjustment (Lift Potentiometer Lower Reference Voltage at 0 mm) 3. 6-2-3, Upper Limit Adjustment (Lift Potentiometer Upper Reference Voltage at 650 mm) 4. 6-2-4, Selection of the Lift Travel Limit (completion) The top of the Senographe system Tube Head can travel up to three different discrete maximum heights, corresponding to each of the three different lift travel limits. Assuming you have accurately set the lower lift travel limit to 670 ±2 mm from the floor, the corresponding maximum Tube Head heights and minimum required ceiling for each of the three different Lift Travel Limits are as follows. Lift Travel Limit Corresponding Upper Optical Fork Position Corresponding Max. Tube Head Height * Recommended Min. Ceiling Height ** 650 mm Bottom 2230 mm 2300 mm 750 mm Middle 2330 mm 2400 mm 850 mm (default setting) Top (default setting) 2430 mm 2500 mm * - Assumes that the lower lift travel limit is accurately set. ** - The recommended minimum ceiling height assumes that there is a marginal gap of 70 mm between the top of the Tube Head and the ceiling. Goal of Calibration: • If the ceiling height has changed, then select the upper optical fork position to an appropriate position (either top, middle or bottom) in order to avoid collision with the ceiling. • Calibrate the Lift Potentiometer. • Set the lift lower limit and the lift travel limit in software, defining the minimum and maximum usable heights. • • • Calibration is necessary to set the lift lower and upper travel limits in software, defining the minimum and maximum usable heights. - The lower limit is set at a pre-determined minimum usable height to establish a reference point for the measurement system (potentiometer and encoder). - The upper limit is then set at the maximum usable height. This may be the maximum attainable by the system, or may be limited to avoid collision with the room ceiling. When the limits have been set, the system is able to take account of arm rotation while controlling lift movement to avoid collisions. Optical sensors (the "optical forks") are used to recognize and stop any movement beyond the software limits, before impact with mechanical stops. Chapter 9 Page no. 1688 JC-CAL-A-031.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A031 - Lift Calibration 6-2 Calibration procedure 6-2-1 Upper Optical Fork Positioning • If the height of the ceiling has changed, then follow the steps in this section, otherwise go to 6-2-2, Lower Limit Adjustment (Lift Potentiometer Lower Reference Voltage at 0 mm). • Use a measuring tape to measure the height of the ceiling: Ceiling Height: ____ mm 1. If the ceiling height is equal to or greater than 2500 mm (98.4 inches) (measured from the floor), - Leave the optical fork in the default position (the upper position, allowing 850 mm lift travel), 2. If the ceiling height is between 2400mm (94.6 inches) and 2500mm (98.4 inches) - Remove the front covers (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). - Place the optical fork in the middle position (allows 750 mm lift travel). 3. If the ceiling height is between 2300mm (90.6 inches) and 2400mm (94.6 inches) - Remove the front covers (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). - Place the optical fork in the lower position (allows 650 mm lift travel). Fork position set by default at installation 850 mm lift travel 100 750 mm lift travel 100 650mm lift travel See Rotation /Lift - Rear View on page 192 to locate the upper optical fork. Note: The ceiling height ranges quoted above assume that there is a 70 mm marginal space between the top of the Tube Head and the ceiling. Page no. 1689 JC-CAL-A-031.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A031 - Lift Calibration 6-2-2 Lower Limit Adjustment (Lift Potentiometer Lower Reference Voltage at 0 mm) Use the following steps to set the lower lift travel limit (which corresponds to the Lift Potentiometer Lower Reference Voltage): 1. Launch the Service Desktop (see Launching the Service Desktop on page 120) then click the Cali2. 3. 4. 5. bration button . From the Calibration Home Page that appears, click the Positionner button. From the Calibration : Positioner Summary page that appears, click the Lift button. From the Lift Position and Upper Limit Calibration page that appears, follow the on-screen instructions: set the arm rotation position to 0° and remove the Bucky.Then press the Start button to start the calibration process. The Gantry LCD updates with the following message: Adjust lower limit. Lower arm until you reach min usable height defined in JC ELE A010. Then press the FOV button. Measure the height of the flat surface of the detector (A) with respect to the top of the gantry base plate (B), as shown. A B 6. Use the control buttons on the Tube Head to move the lift down until the measured height at the detector is 670 ±2 mm (26.4 ±0.1 inches). Note: If you move the detector below the height of 670 ±2 mm height and too close to 660 mm the lower optical fork will be obstructed and force the Senographe system to halt. If you invoke a halt you will have to manually move the lift shaft to raise the detector and start again. 7. When the measured height at the detector is 670 ±2 mm (26.4 ±0.1 inches), press the FOV size button (behind the Tube Head) to signal completion of the lower limit adjustment. The voltage of the Lift Potentiometer is sent to the firmware of the Lift Board and stored as the Lift Potentiometer Lower Reference Voltage. The Gantry LCD updates with the following message: Chapter 9 Page no. 1690 JC-CAL-A-031.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A031 - Lift Calibration Lower position successfully calibrated. Move to upper position. When reached press FOV button. You must now proceed to Upper Limit Adjustment (Lift Potentiometer Upper Reference Voltage at 650 mm) on page 1691 to set the upper Lift Potentiometer Upper Reference Voltage. 6-2-3 Upper Limit Adjustment (Lift Potentiometer Upper Reference Voltage at 650 mm) Use the following steps to calibrate the upper limit of the Lift Potentiometer: 1. When the Gantry LCD instructs you to move the lift to the upper position, use the control buttons on the Tube Head to move the lift up to its highest possible position until it automatically stops. The movement stops automatically when the lift reaches 650 mm above the lower limit (determined by the Lift Encoder which accurately translates lift screw turns to height travelled). 2. Once the lift reaches its highest position and automatically stops, press the FOV size button (behind the Tube Head) to signal completion of the upper limit adjustment. The voltage of the Lift Potentiometer is sent to the firmware of the Lift Board and stored as the Lift Potentiometer Upper Reference Voltage. The Gantry LCD updates with the message "Lift node fully calibrated. Calibration can be saved or canceled on ADS." and the AWS screen updates instructing you to either save or cancel the calibration (see Selection of the Lift Travel Limit (completion) on page 1691). ! Notice: If you do not move the lift up to its highest possible position until it automatically stops, and you press the FOV size button the Gantry LCD updates with the message "Upper lift position out of range. Check lift position or positioner signal! Then press FOV button.". In this case simply continue to move the lift up to its highest possible position until it automatically stops and then press the FOV size button. 6-2-4 Selection of the Lift Travel Limit (completion) Use the following steps to save the calibration results and set the lift travel limit,: 1. On the Lift Position and Upper Limit Calibration page, click the Save button. A Lift Optical Fork Position Calibration page on the appears prompting you to select the upper optical fork position. 2. Click on the button corresponding to the upper optical fork position that you set in Upper Optical Fork Positioning on page 1689. Click the NO CHANGE button if the ceiling height has not changed, otherwise click the corresponding button, as follows: - 850 mm if the upper optical fork is in the upper position - 750 mm if the upper optical fork is in the middle position - 650 mm if the upper optical fork is in the lower position 3. From the Lift Calibration SAVED page that appears, click the OK button. You are returned to the Calibration : Positioner Summary page. 4. From the Calibration : Positioner Summary page, click the Exit button to leave the Service Desktop. 6-2-5 Check the Lift Lower and Upper Travel Limits Move the Arm to the lower position, then to the upper position and check if the Arm stops at the right positions. Page no. 1691 JC-CAL-A-031.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A031 - Lift Calibration This page is blank. Chapter 9 Page no. 1692 JC-CAL-A-031.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A041 - Bad Pixel Calibration Job Card CAL A041 - Bad Pixel Calibration 1 Chapter 9 SUPPLIES None 2 TOOLS Flat field phantom ! Notice: The acrylic must be clean and free from scratches. This is essential to avoid incorrect detection of dead pixels. 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 20 minutes 4 SAFETY PRECAUTIONS WARNING This procedure requires the use of X–rays; take all due precautions. 5 • PREREQUISITES It is strongly recommended to perform bad pixel calibration when the detector has not been used for a while and when Flat Field test fails. The temperature of the detector must be stabilized and within the specified range before commencing and during bad pixel calibration. The Senographe must be in the Medical Application menu. • • 6 BAD PIXEL CALIBRATION 6-1 Description A Bad Pixel is an Image Receptor cell which has a response curve very different from that of other cells subject to the same dose, even after flat field correction. It thus provides no useful information, and appears as a white or black pixel on the image. Bad Pixel Calibration is a process which uses a number of acquisitions to identify such cells and store their positions in a Bad Pixel Map. The bad pixel correction process, applied to acquired images, uses the map to replace the level read from each bad pixel with the mean level of neighboring cells. ! Notice: It is important that the phantom used in these procedures, and all surfaces in the beam (detector, tube, etc.) are very clean and free from imperfections, which can affect the calibration. Page no. 1693 JC-CAL-A-041.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A041 - Bad Pixel Calibration 6-2 Procedure ! Notice: Before starting the calibration, check that the Conditioner temperature has stabilized at 26°C ±2°C. 1. Remove the Bucky and remove the compression paddle. 2. Launch the Service Desktop (see Launching the Service Desktop on page 120). 3. From the Service Desktop, click the Calibration button and select Detector Calibration, after Summary display, click again on Detector. 4. Select Bad pixel and Start; follow the on-screen instructions to run the calibration. 5. The IDC automatically acquires 16 offset images (no X-rays) and computes results. 6. When the offset acquisitions and calculations are complete, you are requested to install the Flat Field phantom (25 mm of acrylic) on the Image Detector. 7. The parameters are automatically set to Rh/Rh; 30kV, 11mAs. Take one acquisition for Image Quality. The IDC computes a first image quality check. If the result is OK, Bad Pixel Calibration can continue. Release the Prep and Expose buttons between each exposure. 8. The parameters are automatically set to Rh/Rh; 30 kV; 56 mAs. Take four exposures. Release the Prep and Expose buttons between each exposure. 9. You are requested to make a low dose exposure. The parameters are set automatically (Rh/Rh; 30 kV; 5.6 mAs). 10. You are requested to make a high dose exposure using the following parameters: (Rh/Rh; 30 kV; 80 mAs). 11. The IDC uses the acquired images to create the bad pixel map which will be used for subsequent image correction. The bad pixel results are displayed on the screen in the form of a table indicating Pass or Fail for all tested specifications. 6-3 Errors WARNING • • • • One Defect category FAIL means that the detector is above the GE Bad Pixel specifications. The root cause of the failure must be found before the customer can use the system for clinical use. If the customer uses a detector having more Bad Pixels than allowed there is a risk to loose information in the clinical images. Exposure abort during calibration. If the X-ray exposure is aborted during bad pixel calibration, the buzzer sounds and the calibration is terminated at the end of the current set of exposures. The calibration must be re-started. If any failure is reported, check to see if the collimator blades are within the detector FOV. If so, correct the problem and try again. If an Isolated bad pixels failure is reported, check detector temperature and repeat the calibration when the temperature is correct. If a Cluster or Bad Columns failure is reported, check the Flat Field phantom for imperfections such as scratches or dust, and repeat the calibration after correction. When a Bad Columns failure is reported, also check that the floppy diskette or CD-ROM supplied with the detector was correctly loaded when the Image Receptor was installed, as instructed in the Job Card D/R A141 - Image Receptor/Digital Detector on page 1099. It contains bad column informa- Chapter 9 Page no. 1694 JC-CAL-A-041.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A041 - Bad Pixel Calibration tion specific to the detector. For more information about Bad Pixel troubleshooting, refer to Job Card TSG A010 - Troubleshooting Bad Pixel Calibration Failure on page 1019. 6-4 Gain Calibration After completing the Bad Pixel calibration, Gain Calibration must be performed for all techniques (perform Job Card CAL A043 - Detector Gain Calibration on page 1697). 7 COMPLETION If you are handing the machine back to the user at this point, switch the Senographe off, then on again. Page no. 1695 JC-CAL-A-041.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A041 - Bad Pixel Calibration This page is blank. Chapter 9 Page no. 1696 JC-CAL-A-041.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A043 - Detector Gain Calibration Job Card CAL A043 - Detector Gain Calibration 1 Chapter 9 SUPPLIES None 2 APPLICABILITY This Job Card applies to the core product. If the system has the CESM option, perform the CESM version of this Job Card located in the CESM IM/SIP instead. 3 TOOLS Flat field phantom 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 40 minutes (15 minutes for Contact and Stereo modes, and 10 minutes for Mag mode) 5 SAFETY PRECAUTIONS The procedures in this Job Card produce X-rays. Ensure that you take appropriate precautions when operating with X-rays (for example, stay behind the radiation screen during an X-ray exposure). 6 • • • PREREQUISITES It is strongly recommended to perform bad pixel calibration when the detector has not been used for a while and when Flat Field test fails. The Senographe must be in the Medical Application menu. Remove the compression paddle. 7 DETECTOR GAIN CALIBRATION 7-1 Principle The goal of gain calibration is to compensate for differences in pixel responses and differences in electronic gain. This calibration makes the image of a flat uniform object look flat (flat field uniformity). 7-2 Procedure 1. Launch the Service Desktop (see Launching the Service Desktop on page 120). 2. From the Service Desktop, click the Calibration button and select Detector Gain Calibration, after Summary display, click again on Detector. 3. Before starting the calibration, follow the on-screen instructions for pre-requisites. 4. Select the config that you want to calibrate and Initialize. 5. Follow the on-screen instructions to set up the system. Install the flat field phantom (25 mm of acrylic) on the Image Receptor (for example). 6. You are requested to check that the collimator is in full FOV, and then to make an exposure for an image quality check. The IQ check technique and parameters are selected automatically. Page no. 1697 JC-CAL-A-043.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A043 - Detector Gain Calibration 7. If the check is successful you are requested to make four exposures for gain calibration. The system selects the calibration technique and parameters. 8. The system uses information from the four exposures to update the gain map; a message appears to indicate successful completion. 9. Repeat the procedure for each of the listed techniques. The following table lists the techniques that must be calibrated, with specified parameters and configurations. Technique for calibration IQ check technique; Configuration Calibration technique 7-3 Mo/Mo/LF/grid Mo/Mo 26 kV 64 mAs, LF; Mo/Mo 26 kV 320 mAs, LF Bucky installed, no paddle. Phantom on Bucky. Mo/Rh/LF/grid Mo/Rh 28 kV 36 mAs, LF; Mo/Rh 28 kV 180 mAs, LF Bucky installed, no paddle. Phantom on Bucky. Rh/Rh/LF/grid Rh/Rh 30 kV 22 mAs, LF; Rh/Rh 30 kV 100 mAs, LF Bucky installed, no paddle. Phantom on Bucky. Mo/Mo/LF/nogrid Mo/Mo 26 kV 32 mAs, LF; Mo/Mo 26 kV 160 mAs, LF No Bucky, no paddle. Phantom on image receptor. Mo/Rh/LF/nogrid Mo/Rh 28 kV 18 mAs, LF; Mo/Rh 28 kV 90 mAs, LF No Bucky, no paddle. Phantom on image receptor. Rh/Rh/LF/nogrid Rh/Rh 30 kV 11 mAs, LF; Rh/Rh 30 kV 56 mAs, LF No Bucky, no paddle. Phantom on image receptor. If the Magnification Option Present 7-3-1 Calibrations If the Magnification option is present, three more Mag mode techniques must be calibrated with specified parameters and configurations, as follows. Technique for calibration IQ check technique; Configuration Calibration technique Mo/Mo/SF/nogrid/mag Mo/Mo 26 kV 45 mAs, SF; Mo/Mo 26 kV 160 mAs, SF No Bucky, no paddle. Phantom on mag. stand (1.8). Mo/Rh/SF/nogrid/mag Mo/Rh 28 kV 24 mAs, SF; Mo/Rh 28 kV 120 mAs, SF No Bucky, no paddle. Phantom on mag. stand (1.8). Rh/Rh/SF/nogrid/mag Rh/Rh 30 kV 20 mAs, SF; Rh/Rh 30 kV 100 mAs, SF No Bucky, no paddle. Phantom on mag. stand (1.8). Chapter 9 Page no. 1698 JC-CAL-A-043.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A043 - Detector Gain Calibration 7-4 If Stereotaxy Option Present 7-4-1 Prerequisites The Stereotaxy option should have been installed and calibrated and plugged-in before performing these six additional gain calibrations. 7-4-2 Calibrations Six more calibrations are needed if the Stereotaxy option is present: Technique for calibration IQ check technique; Configuration Calibration technique Mo/Mo/LF/nogrid/-15° Mo/Mo 26 kV 32 mAs, LF; Mo/Mo 26 kV 160 mAs, LF No Bucky, no paddle. Phantom on image receptor. Arm at -15° Mo/Rh/LF/nogrid/-15° Mo/Rh 28 kV 18 mAs, LF; Mo/Rh 28 kV 90 mAs, LF No Bucky, no paddle. Phantom on image receptor. Arm at -15° Rh/Rh/LF/nogrid/-15° Rh/Rh 30 kV 11 mAs, LF; Rh/Rh 30 kV 56 mAs, LF No Bucky, no paddle. Phantom on image receptor. Arm at -15° Mo/Mo/LF/nogrid/15° Mo/Mo 26 kV 32 mAs, LF; Mo/Mo 26 kV 160 mAs, LF No Bucky, no paddle. Phantom on image receptor. Arm at 15° Mo/Rh/LF/nogrid/15° Mo/Rh 28 kV 18 mAs, LF; Mo/Rh 28 kV 90 mAs, LF No Bucky, no paddle. Phantom on image receptor. Arm at 15° Rh/Rh/LF/nogrid/15° Rh/Rh 30 kV 11 mAs, LF; Rh/Rh 30 kV 56 mAs, LF No Bucky, no paddle. Phantom on image receptor. Arm at 15° If the Stereotix option is present, perform the following steps before running the Detector Gain Calibration: a. Plug the stereotix on the system b. Perform an angulation to reach -15° c. Remove the stereotix d. Launch the first -15° gain configuration e. Perform the exposures for -15° maps as written on the screen f. Perform the other -15° configurations g. Plug the stereotix on the system again h. Perform the angulation to reach +15° i. Remove the stereotix j. Perform the 3 gain maps at 15° k. When all the stereo gain maps are calibrated, move back to the 0° position. l. It is now safe to exit the calibrations. Page no. 1699 JC-CAL-A-043.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A043 - Detector Gain Calibration 8 ERROR ACTIONS If an error is found, an error message appears, with a request for further action. Possible error messages are: 1. IQ check failed - Detector not ready. You are informed that the IQ check failed because the check for detector lag failed, or because the detector temperature was outside limits. You are then requested to try the test again after a 15 minute delay or after the detector temperature has stabilized. 2. IQ check failed - system configuration is not OK. You are asked to repeat the IQ check after checking the system configuration (phantom position, removal of paddle, collimator in field of view). 9 COMPLETION If you are handing the machine back to the user at this point, switch the Senographe off, then on again. Chapter 9 Page no. 1700 JC-CAL-A-043.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A045 - Conversion Factor Measurement Job Card CAL A045 - Conversion Factor Measurement 1 Chapter 9 SUPPLIES None 2 • • • • TOOLS Radcal 2026 Dosimeter 6M ionization chamber (6cc) calibrated at mammographic X ray beam energies Dosimeter support with Radiation Protection Plate IQST Standard Phantom 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 15 minutes 4 SAFETY PRECAUTIONS WARNING This procedure requires the use of X–rays; take all due precautions. 5 PREREQUISITES None 6 CONVERSION FACTOR MEASUREMENT 6-1 Description The Conversion Factor is required for AOP (Automatic Optimization of Parameters) calculations. It is determined by using a dosimeter to measure the X–ray dose while acquiring an image. This value is compared with the brightness of the corrected image to give a Conversion Factor, used by the system to convert brightness to dose for all AOP–related calculations. The brightness and dose values are also sent to the AWS for the image quality tests. Page no. 1701 JC-CAL-A-045.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A045 - Conversion Factor Measurement 6-2 Procedure 1. Launch the Service Desktop (see Launching the Service Desktop on page 120). 2. From the Service Desktop, click the Calibration button and select Detector/Detector/CF Measurement. 3. Before starting the calibration, follow the on-screen instructions for pre-requisites. 4. Select Conversion Factor Measurement and start. 5. Follow the on–screen instructions; a. Remove the Bucky and the compression paddle. b. Install the Dosimeter Support. c. Install the Radiation Protection Plate. d. Place the IQST phantom on the dosimeter support and the dosimeter in the low position (Source– Dosimeter Distance = 622.5 mm). e. Take an exposure (parameters set automatically: Rh/Rh; 30 kV; 56 mAs). f. Read the dosimeter and enter the dose value (in microGray or mR). g. Remove the Dosimeter and Radiation Protection Plate. h. Take a second exposure using the same technique. 6. The IDC calculates the brightness level in the pre-defined region of interest. 7. The IDC computes the counts/microGray value and checks the result. If good, it displays the message Calibration successful. 6-3 • Error codes Calibration calculation failed. 6-4 Completion If you are handing the machine back to the user at this point, switch the Senographe off, then on again. Chapter 9 Page no. 1702 JC-CAL-A-045.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A046 - Half-Value Layer Measurement Job Card CAL A046 - Half-Value Layer Measurement 1 Chapter 9 SUPPLIES None 2 APPLICABILITY This Job Card applies to the core product. If the system has the CESM option, perform the CESM version of this Job Card located in the CESM IM/SIP instead. 3 • • • • TOOLS Radcal 2026 Dosimeter 6M ionization chamber (6cc) calibrated at mammographic X ray beam energies Dosimeter support with Radiation Protection Plate Two sheets of 0.2 mm and 0.5 mm thickness of 99.9% pure aluminum, of length and width sufficient to fully cover the ionization chamber. The stated thickness should be accurate within ±1%, Standard 19 x 23 compression paddle Magstand simulator • • 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 20 minutes 5 SAFETY PRECAUTIONS The procedures in this Job Card produce X-rays. Ensure that you take appropriate precautions when operating with X-rays (for example, stay behind the radiation screen during an X-ray exposure). 6 PREREQUISITES ! Notice: The Detector must be protected with the Radiation Protection Plate. 7 INTRODUCTION The purpose of this procedure is to verify that the Half-value layer of the X-ray beam is adequate to minimize patient breast dose, while not so excessive that contrast is lost in the resultant image. The tube yield is measured for all track/filter/focal spot combinations and the values used for skin dose computation. For each spectrum the HVL and tube Yield are determined and stored on the Senographe, for use in the skin dose and Mean Glandular Dose evaluation. • The following techniques will be set automatically by the Senographe: • Configuration Technique Mo/Mo 26kV/63mAs Mo/Rh 28kV/56mAs Rh/Rh 30kV/45mAs The calibration of each configuration (focal spot, track/filter) is independent of the results obtained in Page no. 1703 JC-CAL-A-046.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A046 - Half-Value Layer Measurement other configurations. 8 PROCEDURE ! Notice: The dose values to be entered in the X-ray Console menu must be expressed in mGy. - If your dosimeter displays dose values in mR, divide the reading by 114.2 to obtain mGy. - If your dosimeter displays dose values in μGy, divide the reading by 1000 to obtain mGy. Note that you must use the format x.xxx E+0 to enter a dose value x.xxx. 1. Ensure that paddle decompression at end of exposure is set to “NO”. In the X-ray Console menu, set: MEDICAL/DECOMP/DECOMP/NO 2. Place the standard 19 cm x 23 cm compression paddle upside down as close as possible to the Xray tube. 3. Remove the Bucky or breast support; place the Dosimeter Support with Radiation Protection Plate on the image receptor. 4. Place the dosimeter with 6M chamber on the high position of the Dosimeter Support (the source-todosimeter distance SDD = 592mm). 5. Select the 9 x 9 collimator format; verify using the light beam that the 6M ionization chamber is fully in the beam. 6. In the HVL/Yield calibration menu on the X-ray Console, enter the path corresponding to the Large Focus (LF) configuration you are measuring: Configuration X-Ray Console Path Mo/Mo SET UP/GENE/INSTAL/GENE/DOSE /LF/MOMO/CALIB/0/CALIB Mo/Rh SET UP/GENE/INSTAL/GENE/DOSE /LF/MORH/CALIB/0/CALIB Rh/Rh SET UP/GENE/INSTAL/GENE/DOSE /LF/RHRH/CALIB/0/CALIB The Senographe automatically selects the acquisition parameters (see table above). 7. Take the calibration exposure (press the Exposure button on the X-ray Console) with no aluminum sheet on the compression paddle, and read the dose value on the dosimeter. 8. Press Set Up once on X-ray Console, select Meas.D, enter the dose value E0 in mGy (see Notice above) and press Valid. 9. Press Set Up twice, and select 0.2. Chapter 9 Page no. 1704 JC-CAL-A-046.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A046 - Half-Value Layer Measurement 10. Place 0.2 mm aluminum on top of the compression paddle; verify using the light beam that the aluminum sheet fully covers the ionization chamber field of view. 11. Take the calibration exposure (press the Exposure button on the X-ray Console) with the 0.2 mm aluminum sheet on the compression paddle, and read the dose value on the dosimeter. 12. Press Set Up once on X-ray Console, select Meas.D, enter the dose value E0 in mGy (see Notice above) and press Valid. 13. Press Set Up twice, and select 0.5 14. Place 0.5 mm aluminum on top of the paddle. Verify using light beam that the aluminum sheet fully covers the ionization chamber field of view. 15. Take the calibration exposure (press the Exposure button on the X-ray Console) with the 0.5 mm aluminum sheet on the compression paddle, and read the dose value on the dosimeter. 16. Press Set Up once on X-ray Console, select Meas.D, enter the dose value E0 in mGy (see Notice above) and press Valid. 17. Press Set Up twice, and press Calcul. 18. Press Set Up, press Param, verify that the value is within the limits given below (Acceptable Values) 19. If the values are within limits, the Senographe stores HVL and Yield values. If not, check the following and repeat the calibration: • Paddle is present, • Dosimeter is properly calibrated, • 6M probe is correctly placed in the high position of the dosimeter holder tool • Tube tilt and format are correctly calibrated, and probe is in the 9x9 field of view • Generator kV and mA are properly calibrated. If the calibration still fails, the tube must be replaced. 20. Repeat steps 6 through 19 for the other track/filter/focal spot combinations: LF/MoRh, LF/RhRh techniques, and once all three combinations are complete, proceed to step 21. 21. Press Set up and perform a checksum (SETUP/GENE/INSTAL/CKSUM/CKSUM). 22. Press Set up and exit the Calibration Menu. 23. Insert Magstand Simulator. Note: Even if the Senographe system is not delivered with the Mag Stands, you must still perform all of the Small Focus (Mag Mode) calibrations listed below. This is because the Magnification Option Installation Manual does not include a Job Card to perform the HVL Measurement in Mag Mode. 24. In the HVL/Yield calibration menu on the X-ray Console, enter the path corresponding to the Small Focus (SF) configuration you are measuring: Configuration X-Ray Console Path Mo/Mo SET UP/GENE/INSTAL/GENE/DOSE /SF/MOMO/CALIB/0/CALIB Mo/Rh SET UP/GENE/INSTAL/GENE/DOSE /SF/MORH/CALIB/0/CALIB Rh/Rh SET UP/GENE/INSTAL/GENE/DOSE /SF/RHRH/CALIB/0/CALIB The Senographe automatically selects the acquisition parameters (see table above). 25. Take the calibration exposure (press the Exposure button on the X-ray Console) with no aluminum sheet on the compression paddle, and read the dose value on the dosimeter. Page no. 1705 JC-CAL-A-046.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A046 - Half-Value Layer Measurement 26. Press Set Up once on X-ray Console, select Meas.D, enter the dose value E0 in mGy (see Notice above) and press Valid. 27. Press Set Up twice, and select 0.2. 28. Place 0.2 mm aluminum on top of the compression paddle; verify using the light beam that the aluminum sheet fully covers the ionization chamber field of view. 29. Take the calibration exposure (press the Exposure button on the X-ray Console) with the 0.2 mm aluminum sheet on the compression paddle, and read the dose value on the dosimeter. 30. Press Set Up once on X-ray Console, select Meas.D, enter the dose value E0 in mGy (see Notice above) and press Valid. 31. Press Set Up twice, and select 0.5 32. Place 0.5 mm aluminum on top of the paddle. Verify using light beam that the aluminum sheet fully covers the ionization chamber field of view. 33. Take the calibration exposure (press the Exposure button on the X-ray Console) with the 0.5 mm aluminum sheet on the compression paddle, and read the dose value on the dosimeter. 34. Press Set Up once on X-ray Console, select Meas.D, enter the dose value E0 in mGy (see Notice above) and press Valid. 35. Press Set Up twice, and press Calcul. 36. Press Set Up, press Param, verify that the value is within the limits given below (Acceptable Values) 37. If the values are within limits, the Senographe stores HVL and Yield values. If not, check the following and repeat the calibration: • Paddle is present, • Dosimeter is properly calibrated, • 6M probe is correctly placed in the high position of the dosimeter holder tool • Tube tilt and format are correctly calibrated, and probe is in the 9x9 field of view • Generator kV and mA are properly calibrated. If the calibration still fails, the tube must be replaced. 38. Repeat steps 24 through 37 for the other track/filter/focal spot combinations: SF/MoRh, SF/RhRh techniques, and once all three combinations are complete, proceed to step 39. 39. Press Set up and perform a checksum (SETUP/GENE/INSTAL/CKSUM/CKSUM). 40. Press Set up and exit the Calibration Menu. 41. Remove the compression paddle. 8-1 Acceptable values: The specification limits for HVL and Yield values measured under these conditions are: Chapter 9 Configuration HVL (mm Al) Yield (μGy/mAs) MoMo 26kV 0.29 - 0.38 35 – 130 MoRh 28kV 0.31 - 0.47 35 – 130 RhRh 30kV 0.33 - 0.52 35 – 130 Page no. 1706 JC-CAL-A-046.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A046 - Half-Value Layer Measurement 8-2 Information: The Senographe automatically computes the HVL by interpolation using the following formula: HVL = 0.5* ln(2 E 0.2 / E 0 ) − 0.2 ∗ ln(2 E 0.5 / E 0 ) ln(Ε 0.2 / Ε 0.5 ) (the units are mm of Al) Where E0, E0.2, E0.5, are dose values measured behind 0, 0.2 mm and 0.5 mm aluminum respectively. The Senographe calculates Tube Yield as E0 / mAs (unit: mGy/mAs) for this technique. 9 COMPLETION If you are handing the machine back to the user at this point, switch the Senographe off, then on again. Page no. 1707 JC-CAL-A-046.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A046 - Half-Value Layer Measurement This page is blank. Chapter 9 Page no. 1708 JC-CAL-A-046.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A048 - Calibration of Compression Force Sensor Job Card CAL A048 - Calibration of Compression Force Sensor 1 Chapter 9 SUPPLIES None 2 • • TOOLS Calibrated force detector capable of measuring compression force between the compression paddle and the image receptor: required accuracy ±0.5 daN. The Mammography compression scale with digital display is recommended. Set of acrylic plates 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 20 minutes 4 SAFETY PRECAUTIONS None 5 PREREQUISITES None 6 COMPRESSION FORCE CALIBRATION 6-1 Principle • • The compression force sensor is factory calibrated. However, if parts have been replaced or disturbed which affect the software or hardware settings, calibration must be carried out. The calibration establishes a suitable transfer function relating the signal from the internal force sensor to the true force. This is done by comparing the force reported by the internal sensor with the force measured externally by a calibrated force detector at several points over the working range. The system software can then calculate compression forces to an accuracy of 1 daN. Note: If the Paddle Holder Assembly, Force Sensor or Paddle Holder Board has been replaced it is possible that system reports 122/021H03 COMPRESSION CONTROL ERROR on the Gantry LCD Readout when Gantry is powered on. This error can occur when the old calibration information stored in the system differs too much from the parts that have been installed causing system to think that compression force is out of allowed range. When this situation happens it is not possible to enter calibration mode. If this happens first try adding some compresion force with the manual compression knobs and reboot the Gantry. Try 10, 20 and 30 daN and use calibrated force sensor to measure it. If the system does not boot with any of these settings remove compression by manual knobs and add 10daN negative force by adding approximately a10 kg mass on top of the Paddle. When the system boots, enter the calibration mode and when the Gantry LCD Readout requests calibration for 0 daN force remove the compression or weight on paddle and continue calibration normally. Page no. 1709 JC-CAL-A-048.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A048 - Calibration of Compression Force Sensor 6-2 Calibration procedure 1. Select the Compression Force Sensor Calibration on the AWS Screen: Service Desktop/Calibration/Positioner/Compression and press START. 2. You are asked to follow the instructions displayed on the Gantry readout, summarized here: - Set the arm rotation to 0°. - Install the standard 19 x 23 cm compression paddle. - Install the Bucky. - Place a 10 mm acrylic plate (minimum dimensions 200 x 200 mm) on the Bucky. - Place the calibrated force detector on the acrylic. 3. The Gantry readout displays a series of force values to be applied, starting with 0 daN. 4. For each requested force, use the manual compression knobs to move the paddle down until the external force detector displays the requested force. Press the collimator FOV size button (behind the tube head) to signal to the system that the requested force is applied and a measurement can be taken. 5. If an error message appears, follow the instructions of the message. 6. When all requested force values have been successfully measured by the system, save the calibration results by clicking the Save button on the AWS screen. 7. If you wish to exit the calibration without saving the results (leaving the system un-calibrated or using the previous settings), click the Cancel button on the AWS screen. 6-3 Verification of the Compression Force Sensor calibration Note: If you are re-calibrating a Compression board that already contains calibration information (e.g. you are performing a re-calibration of an existing Compression board) then you can directly follow the verification steps below. If you are calibrating a Compression board that does not contain calibration information (e.g. you have changed the Compression board, or have updated the software on the Compression board) then you must manually move up the compression paddle and remove it, then perform Compression Thickness Calibration on page 1721 in Job Card CAL A050 - Compression Thickness Calibration before you follow the verification steps below. If you do not perform these steps first then you will witness a 121/003 COMPRESSION CALIB NOT ACHIEVED error. 1. After completing the compression calibration procedure, return to normal application mode. 2. If necessary, install the compression paddle. 3. Set the system as described above for calibration, with the external calibrated force detector in place on the Bucky. 4. Apply compression to the external force detector. The applied compression force is measured by the system and displayed on the Gantry readout. 5. Use the manual compression knobs to apply compressions of 5, 10, 15, 20, and 30 daN For each value, check that the forces displayed on the external detector and on the Gantry readout agree within ±1 daN. CAUTION After 27 daN, reach manually 30 daN using the compression knobs. To avoid any disengaging mechanism, press the paddle at the same time. 6. If any result is out of range, repeat the calibration procedure. Chapter 9 Page no. 1710 JC-CAL-A-048.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A049 - Compression Paddle Offset Calibration Job Card CAL A049 - Compression Paddle Offset Calibration 1 Chapter 9 SUPPLIES None 2 TOOLS Set of acrylic plates Calipers 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 5 minutes per Compression Paddle (approximately 40 minutes for a set of Compression Paddles) 4 SAFETY PRECAUTIONS No specific safety precautions are applicable. 5 APPLICABILITY This Job Card should be used if you witness problems when peforming Job Card ELE A038 - AOP Mode and SNR Check on page 707 and you have a Gantry CPU Board running NSC 1.2.13 or above. 6 PREREQUISITES The procedure to calibrate the final offset for each Compression Paddle uses a command, whose syntax refers to the padlle number. Before proceeding, consult Table 1 to know which paddle number corresponds to each of the Compression Paddles delivered with the system. TABLE 1 - PADDLE NUMBER REFERENCES Paddle Number Products Compression Paddle Name 1 DS Flexible 19x23 (2383182-2) 2 DS Standard 19x23 (2373344) (Ref. Number on Label) Page no. 1711 JC-CAL-A-049.fm Photo Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A049 - Compression Paddle Offset Calibration Paddle Number Products 3 DS Axillary (2373360) 4 DS Round spot (2373347) 5 DS Square spot (2373343) 6 DS Essential 2D Large localization paddle DS : (2373385) Essential : (5172704) 7 DS Essential 2D Spot localization paddle DS : (2373389) Essential : (5172624) 11 N/A High wall (Not yet available, future use) Chapter 9 Compression Paddle Name Photo (Ref. Number on Label) N/A Page no. 1712 JC-CAL-A-049.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A049 - Compression Paddle Offset Calibration Paddle Number Products Compression Paddle Name 12 DS Essential 19 x 23 magnification paddle DS : (2397559) Essential : (5172828) 14 DS Essential Round spot magnification paddle DS : (2397557) Essential : (5172946) 15 DS Essential Square magnification paddle DS : (2397558) Essential : (5172686) 16 Essential Flexible sliding 19 x 23 paddle (5144833) (Ref. Number on Label) Page no. 1713 JC-CAL-A-049.fm Photo Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A049 - Compression Paddle Offset Calibration Paddle Number Products 17 Essential Sliding 19 x 23 paddle (5144832-2) 18 Essential Sliding round spot paddle (5144836) 19 Essential Sliding square spot paddle (5144835) 20 Essential 2D Large localization paddle (sliding) (Not yet available, future use) N/A 21 Essential 2D Spot localization paddle (sliding) (Not yet available, future use) N/A 22 Essential 24 x 31 paddle (5173061) Chapter 9 Compression Paddle Name Photo (Ref. Number on Label) Page no. 1714 JC-CAL-A-049.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A049 - Compression Paddle Offset Calibration Paddle Number Products 23 Essential Compression Paddle Name (Ref. Number on Label) Flexible 24 x 31 paddle (5172164) Page no. 1715 JC-CAL-A-049.fm Photo Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A049 - Compression Paddle Offset Calibration 7 PROCEDURE 7-1 Display the existing Offset for Compression Paddles Before specifying the final offest you must see if an existing offset is already declared. This existing offset value will need to be added to the current offset that you determine in Section 7-2, page 1717 in order to determine the final offset. To display the existing offsets, proceed as follows: 1. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 2. Make a Telnet connection with the Gantry CPU Board, by entering: telnet pos 3. At the -> prompt that appears, display the existing offsets for the Compression Paddles, by entering: displayPaddleOffsets A list of paddle offets similar to the following appears. --------------------------------------------------No - Paddle Deformation Offset (1/10th mm)) --------------------------------------------------1 - Phlex 19x23 0 2 - Std 19x23 0 3 - Auxiliary 0 4 - Round spot 0 5 - Square spot 0 6 - Biopsy 0 7 - Spot biopsy 0 11 - High wall 0 12 - Std mag stand 0 14 - Round mag stand 0 15 - Square mag stand 0 16 - Phlex 19x23 sliding 0 17 - Std 19x23 sliding 0 18 - Round spot sliding 0 19 - Square spot sliding -3 20 - Biopsy sliding 0 21 - Spot biopsy sliding 0 22 - Std 24x30 0 23 - Phlex 24x30 0 4. The existing offset values are displayed in 1/10ths of a mm. • Record the displayed offset values (in 1/10ths of a mm) in column A of Table 2. Keep the telnet window open, as you will use this again in section 7-3 page 1717. Chapter 9 Page no. 1716 JC-CAL-A-049.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A049 - Compression Paddle Offset Calibration 7-2 Determine the Current Offset for Each of the Compression Paddles For each of the Compression Paddles, do the following to determine their offset: 1. Insert the Compression Paddle and Breast Support. 2. Use a set of calipers to measure the thickness of the 40 mm acrylic plate, and use this measured value for the basis of the known thickness. Convert the known thickness in 1/10 th of a mm by mulitplying the known thickness by 10. Record this converted value in column B of Table 2 on page 1719. 3. Place the 40 mm acrylic plate (of known thickness) on the Breast Support. 4. Lower the Compression Paddle so that it is in contact with the 40 mm acrylic plate (of known thickness), and apply a compression of 10 daN. 5. Calculate the offset between the thickness reported on the Gantry LCD Readout and the 40 mm acrylic plate (of known thickness), using the following equation: Offset (in mm) = (known thickness of 40 mm acrylic plate - Gantry LCD Readout) The offset can be a positive or negative value. The offset is positive if the known thickness is greater than that displayed on the Gantry LCD Readout. The offset is negative if the known thickness is less than that displayed on the Gantry LCD Readout. 6. Convert the calculated offset in 1/10 th of a mm by mulitplying the coffset by 10. Record this converted value in column C of Table 2 on page 1719. 7-3 Specify final the Offset for Each of the Compression Paddles Specify the final offset (in 1/10 th of mm) of the Compression Paddles on the Gantry CPU board, as follows: 1. Calculate the final offset (in 1/10 th of mm) by adding the value from column A and column D. 2. At the -> prompt that appears, execute the following command for each of the Compression Paddles whose offset you want to declare: setPaddleOffset , where: - is the paddle number corresponding to the Compression Paddle you want to declare (see Table 1 on page 1711 for a mapping or paddle number to Compression Paddles). - is the final offset (in 1/10th of a mm) that you derived in column E of Table 2 on page 1719. For example, if for the Sliding square spot paddle (paddle number 19) the initial offset was -0.2 mm and the existing offset was -0.2 mm, the final offset is -0.4 mm. In this case you would specify 4 for the final offset, by entering: setPaddleOffset 19,-4 Repeat this command for each of the Compression Paddles whose final offset you want to declare. 3. Check that the offsets for the Compression Paddles are correctly registered on the Gantry CPU board, by entering: displayPaddleOffsets Page no. 1717 JC-CAL-A-049.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A049 - Compression Paddle Offset Calibration A list of paddle offets similar to the following appears. --------------------------------------------------No - Paddle Deformation Offset (1/10th mm)) --------------------------------------------------1 - Phlex 19x23 0 2 - Std 19x23 0 3 - Auxiliary 0 4 - Round spot 0 5 - Square spot 0 6 - Biopsy 0 7 - Spot biopsy 0 11 - High wall 0 12 - Std mag stand 0 14 - Round mag stand 0 15 - Square mag stand 0 16 - Phlex 19x23 sliding 0 17 - Std 19x23 sliding 0 18 - Round spot sliding 0 19 - Square spot sliding -3 20 - Biopsy sliding 0 21 - Spot biopsy sliding 0 22 - Std 24x30 0 23 - Phlex 24x30 0 4. If any of the final offset values are not as expected, repeat procedure from step 2 of Section 7-2 Determine the Current Offset for Each of the Compression Paddles on page 1717 for the appropriate Compression Paddle(s). 5. For each Compression Paddle you changed the offset for, follow these steps: a. Insert the compression Paddle. b. Apply a compresison of 10 dAN. c. Verify the Gantry LCD Readout displays exactly the known thickness of the 40 mm acrylic plate, as measured in step 2 of Section 7-2 Determine the Current Offset for Each of the Compression Paddles on page 1717. If the LCD readout does not display exactly the known thickness of the 40 mm acrylic plate, repeat the calibration procedure starting from step 2 of Section 7-2 Determine the Current Offset for Each of the Compression Paddles on page 1717. 6. If all of the offset values are as expected, exit the telnet connection with the Gantry CPU Board, by entering: logout Chapter 9 Page no. 1718 JC-CAL-A-049.fm B C (Ref. Number on Label) Existing Offset in displayed in 1/10th of a mm Known Thickness in 1/10th of a mm Calculated Offset in 1/10th of a mm 1 Flexible 19x23 (2383182-2) 2 Standard 19x23 (2373344) 3 Axillary (2373360) 4 Round spot (2373347) 5 Square spot (2373343) 6 2D Large localization paddle DS : (2373385) Essential : (5172704) 7 2D Spot localization paddle DS : (2373389) Essential : (5172624) 11 High wall (Not yet available, future use) 12 19 x 23 magnification paddle DS : (2397559) Essential : (5172828) 14 Round spot magnification paddle DS : (2397557) Essential : (5172946) 15 7 x 7 square magnification paddle DS : (2397558) Essential : (5172686) D Final Offset to declare in 1/10th of a mm (i.e. value from Column A + value from column C) Senographe DS A Service Information and Procedures Class A 2385072-16-8EN Chapter 9 Compression Paddle Name Job Card CAL A049 - Compression Paddle Offset Calibration Page no. 1719 Paddle Number GE Healthcare Revision 1 JC-CAL-A-049.fm TABLE 2 - COMPRESSION PADDLE OFFSETS C (Ref. Number on Label) Existing Offset in displayed in 1/10th of a mm Known Thickness in 1/10th of a mm Calculated Offset in 1/10th of a mm 16 Flexible sliding 19 x 23 paddle (5144833) 17 Sliding 19 x 23 paddle (5144832-2) 18 Sliding round spot paddle (5144836) 19 Sliding square spot paddle (5144835) 20 2D Large localization paddle (sliding) (Not yet available, future use) 21 2D Spot localization paddle (sliding) (Not yet available, future use) 22 24 x 31 paddle (5173061) 23 Flexible 24 x 31 paddle (5172164) COMPLETION Restart the Gantry by powering OFF/ON from the X-ray Console. D Final Offset to declare in 1/10th of a mm (i.e. value from Column A + value from column C) GE Healthcare B Senographe DS JC-CAL-A-049.fm Service Information and Procedures Class A 2385072-16-8EN A Revision 1 Page no. 1720 Compression Paddle Name Job Card CAL A049 - Compression Paddle Offset Calibration Chapter 9 8 Paddle Number GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A050 - Compression Thickness Calibration Job Card CAL A050 - Compression Thickness Calibration 1 Chapter 9 SUPPLIES None 2 TOOLS Set of acrylic plates 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 10 minutes 4 SAFETY PRECAUTIONS 5 PREREQUISITES • • Remove the Compression Paddle Remove the Bucky 6 COMPRESSION THICKNESS CALIBRATION The purpose of breast thickness calibration is to calibrate the absolute breast thickness measurement which is given by a linear potentiometer linked to the compression carriage. This is done by defining two points in the range of travel of the compression carriage. 6-1 Paddle Holder Travel Limits 1. Select the Compression Thickness Calibration on the AWS Screen: Service Desktop/Calibration/ Positioner/Breast Thickness and press START. The Gantry Readout displays the procedure to follow. 2. Press the footswitch continuously (do not release the compression pedal until the movement stops automatically) to reach the lowest mechanical position of the compression. Press the collimator FOV size button (behind the tube head) to register this position. 3. Press the footswitch continuously to reach the upper position and register this position with the FOV size button. 4. If an error message appears, follow the instructions of the message. 5. Save the calibration results by clicking the Save button on the AWS screen. 6. If you wish to exit the calibration without saving the results (leaving the system un-calibrated or using the previous settings), click the Cancel button on the AWS screen. 7. Exit the Calibration Mode. Page no. 1721 JC-CAL-A-050.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A050 - Compression Thickness Calibration 6-2 Check the Thickness Measurement in Contact Mode Note: If you are re-calibrating a Compression board that already contains calibration information (e.g. you are performing a re-calibration of an existing Compression board) then you can directly follow the verification steps below. If you are calibrating a Compression board that does not contain calibration information (e.g. you have changed the Compression board, or have updated the software on the Compression board) then you must perform Compression Force Calibration on page 1709 in Job Card CAL A048 - Calibration of Compression Force Sensor before you follow the verification steps below, otherwise you will witness a compression-related error. 1. Place the Standard Compression Paddle. 2. Still in contact mode, place the corner of a 40 mm thick acrylic plate (1).The plate must be positioned at 45°, entering about 80 mm from the chest wall. 3. Lower the compression paddle into contact with the acrylic. 4. Verify for any compression force between zero and 20 daN of compression (as displayed on the Gantry readout), that the breast thickness displayed on the Gantry readout is equal to 40 mm +/- 2 mm. Chapter 9 80 mm +/- 5mm 1 Page no. 1722 JC-CAL-A-050.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A051 - AOP Calibration Job Card CAL A051 - AOP Calibration 1 Chapter 9 SUPPLIES None 2 APPLICABILITY This Job Card applies to the core product. If the system has the CESM option, perform the CESM version of this Job Card located in the CESM IM/SIP instead. 3 TOOLS Flat field phantom 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 20 minutes 5 SAFETY PRECAUTIONS The procedures in this Job Card produce X-rays. Ensure that you take appropriate precautions when operating with X-rays (for example, stay behind the radiation screen during an X-ray exposure). 6 PREREQUISITES None 7 PROCEDURE 7-1 Presentation This procedure will be done for the three following techniques: • With Grid and Large Focal Spot. • Stereotix and Large Focal Spot (if Stereo option present). • With No Grid and Small Focal Spot (if Magnification option present). Note: AOP Calibration is required to adapt AOP parameters to tube yield (mGy/mAs). 7-2 Calibration with Grid/Large Focal Spot configuration 1. 2. 3. 4. Close the exam window if it is open. Insert the Bucky. Place the Flat Field Phantom on the Bucky. Compress the phantom at 4daN using the standard 19 x 23 paddle for contact mode (Ref. Number 2373344). 5. Select Large Focal Spot from the X-ray Console menu. 6. From the X-ray Console, enter the SETUP/GENE/INSTAL/GENE/AOP/APOLLO/CALIB/GRIDLF menu. 7. Press CALIB. 8. Press the Exposure button on the X-ray Console and hold it down. Three exposures are taken Page no. 1723 JC-CAL-A-051.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A051 - AOP Calibration (about 20 seconds), then CALIBRATION END appears on the X-ray Console display. Release the Exposure button . 9. Perform a checksum (SETUP/SETUP/SETUP/SETUP/SETUP/SETUP/CKSUM/CKSUM). 10. Exit the Calibration Menu (SETUP/SETUP/SETUP//SETUP/SETUP). 7-3 Calibration with Stereo configuration Note: This calibration is applicable only if the Stereo option is present. 1. Remove the Bucky and insert the Stereotix with the paddle without biopsy window. 2. Place the Flat Field Phantom on the Stereotix. 3. Compress the acrylic. 4. Select Large Focal Spot from the X-ray Console. 5. From the X-ray Console, enter the SETUP/GENE/INSTAL/GENE/AOP/APOLLO/CALIB/ NOGRIDLF menu. 6. Press CALIB. 7. Press the Exposure button on the X-ray Console and hold it down. Three exposures are taken (about 20 seconds), then CALIBRATION END appears on the X-ray Console display. Release the Exposure button . 8. Perform a checksum (SETUP/SETUP/SETUP/SETUP/SETUP/SETUP/CKSUM/CKSUM). 9. Exit the Calibration Menu (SETUP/SETUP/SETUP/SETUP/SETUP). 7-4 Calibration with No Grid/Small Focal Spot configuration Note: This calibration is applicable only if the Magnification option is present. 1. Remove the Bucky. 2. Install the 1.8 magnification Mag Stand; the calibration switches automatically to Small Focal Spot configuration. 3. Place the Flat Field Phantom on the magnification stand. 4. Compress the phantom at 4daN using the standard 19 x 23 Magnification paddle (Ref. Number 2397559). 5. From the X-ray Console, enter the SETUP/GENE/INSTAL/GENE/AOP/APOLLO/CALIB/ NOGRIDSF menu. 6. Press CALIB. 7. Press the Exposure button on the X-ray Console and hold it down. Three exposures are taken (about 20 seconds), then CALIBRATION END appears on the X-ray Console display. Release the Exposure button . 8. Perform a checksum (SETUP/SETUP/SETUP/SETUP/SETUP/SETUP/CKSUM/CKSUM). 9. Exit the Calibration Menu (SETUP/SETUP/SETUP/SETUP/SETUP). 8 COMPLETION If you are handing the machine back to the user at this point, switch the Senographe off, then on again. Chapter 9 Page no. 1724 JC-CAL-A-051.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A053 - mAs Non-linearity Calibration Job Card CAL A053 - mAs Non-linearity Calibration 1 Chapter 9 SUPPLIES None 2 TOOLS Flat field phantom 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 10 minutes 4 SAFETY PRECAUTIONS The procedures in this Job Card produce X-rays. Ensure that you take appropriate precautions when operating with X-rays (for example, stay behind the radiation screen during an X-ray exposure). 5 PREREQUISITES None 6 PROCEDURE 6-1 Presentation The object of mAs non-linearity calibration is to compensate for the non-linearity of exposure delivered by the Generator at low mAs values, as used in AOP pre-exposure operations. This procedure measures pre-exposure linearity deviation, and stores a correction factor in the X-ray Console menu, to be applied to the mAs value of all AOP exposures. The correction factor is automatically calculated as: MASPRE CORR = S100 / (25 x S4), where S100 and S4 are the signals measured in the 100 mAs image and the 4 mAs image respectively. 6-2 Procedure 1. Install the Flat Field Phantom on the Bucky. 2. Install the paddle without compressing the phantom. 3. From the X-ray Console menu, enter the SET UP/GENE/INSTAL/GENE/AOP/APOLLO/CALIB/ mAsPRE/CALIB menu. 4. Press CALIB. 5. Press the Exposure button on the X-ray Console and hold it down. Two exposures are taken (about 20 seconds), then CALIBRATION END appears on the X-ray Console display. Release the Exposure button . Parameters for the two exposures are automatically set to MoMo/28 kV/4 mAs and MoMo/28 kV/100 mAs. 6. Press SETUP once, then press PARAM. 7. Verify that the value displayed for MASPRE CORR is within the limits given below (Acceptable values). 8. Perform a checksum (SETUP/SETUP/SETUP/SETUP/SETUP/SETUP/CKSUM/CKSUM). Page no. 1725 JC-CAL-A-053.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CAL A053 - mAs Non-linearity Calibration 9. Exit the Calibration Menu (SETUP/SETUP/SETUP//SETUP/SETUP). 6-3 • • 7 Acceptable Values The value displayed for MASPRE CORR should be within the limits 1.00 and 1.20. If it is outside this range, check the Generator calibration and repeat the calibration. COMPLETION If you are handing the machine back to the user at this point, switch the Senographe off, then on again. Chapter 9 Page no. 1726 JC-CAL-A-053.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Verification checks VERIFICATION CHECKS CHAPTER 9 Verification/checking information is given in the following modules: - Job Card CHK A001 - Boot/Init and Shutdown on page 1729 Job Card CHK A003 - UPS Batteries on page 1737 Job Card CHK A004 - DICOM Printer Adjustments and Checks on page 1741 Job Card CHK A011 - Check kVp settings on page 1745 Job Card CHK A013 - Check mA and mAs settings on page 1755 Page no. 1727 Check.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Verification checks This page is blank. Chapter 9 Page no. 1728 Check.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A001 - Boot/Init and Shutdown Job Card CHK A001 - Boot/Init and Shutdown 1 Chapter 9 SUPPLIES None 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 20 minutes 4 • SAFETY PRECAUTIONS. To remove power from the complete system, switch off the external circuit breaker which connects the system to the hospital supply. There are two circuit breakers inside the Generator Cabinet, one for the Gantry and Generator, the other for the Control Station and imaging equipment. Switching off one of these breakers removes power from only part of the system. Remember that the UPS will continue to supply power to parts of the Control Station and imaging equipment until it is shut down. NEVER switch off the UPS manually (risk of data loss). NEVER switch off power to the Conditioner except in emergency (risk of damage to the Detector if the correct conditions of temperature and humidity are not maintained). • • • WARNING In normal operation (circuit breakers closed): Power is present in the Generator Cabinet, MDR, and Control Station at all times, even after the AWS, UPS, and other components have shut down. Control Station components remain powered by the UPS for about two minutes after switch off. The 230 V supply to the Conditioner the UPS, and the Light Box is maintained at all times. 5 PREREQUISITES None Page no. 1729 JC-CHK-A-001.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A001 - Boot/Init and Shutdown 6 PROCEDURE This Job Card provides check lists for confirmation of the correct operation of power up and power down sequences, and for the steady state conditions to be expected with power on or off. • Refer to the Power Supply Schematic diagram overleaf for an overview of power connections. • In normal operation, system power switches are used as follows: Power comes from the hospital supply circuit breaker to the Generator Circuit Breaker and to a circuit breaker in the MDR (the Main Distribution Rack at the top of the Generator Cabinet), in parallel. Both circuit breakers are normally left ON. All subsystem power switches (items in the Control Station, Conditioner, etc.) are normally left ON. The system is normally switched ON using the ON switch (I) on the Gantry Console. The system is normally switched OFF by clicking the System Off button in the Browser window. When switching off, wait for complete system and UPS shut down (about two minutes). The Gantry and Generator can be switched OFF without affecting components in the Control Station by pressing the OFF switch (STOP) on the Gantry Console. MDR Breaker ON/OFF push buttons: Conditioner and MDR Conditioner Detector supply Control Station UPS Generator Generator Breaker Chapter 9 Page no. 1730 JC-CHK-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A001 - Boot/Init and Shutdown 7 POWER OFF STATE CHECKS Remove Generator Cabinet covers as required for access to the main circuit breaker in the MDR, the Generator circuit breaker, the Conditioner, and to the pushbuttons controlling power to the Conditioner and the Detector. 7-1 Normal power OFF state checks For these power OFF checks, the MDR and Generator circuit breakers should be closed (ON), and the system should have been switched off using the normal OK NOT OK power off sequence (by clicking the System Off button in the Browser window). Check: • No display on the X-ray Console and STOP push-button is lit. • No display on the AWS monitor and no monitor LED lit. • None of the UPS front panel LEDs are lit (visible through the acrylic cover at the base of the Control Station). The Control Station and Conditioner pushbuttons ON (inside the MDR) are lit. The Conditioner is powered up and operating normally. • • 7-2 Complete power OFF state checks For these checks, all items, including the UPS and conditioner, must first be switched off. Starting from the normal power off state as described above, proceed as follows: 1. Switch the MDR circuit breaker OFF 2. Switch the Generator circuit breaker OFF Remember that mains power is still present in the cabinet, at the input to the breakers. 3. Check the following: • No LED lit in the Generator Cabinet • No LED lit in the MDR. • None of the internal and external pushbuttons in/on the MDR are lit. • The Conditioner is not running (no LCD display, no sound from the pump) Page no. 1731 JC-CHK-A-001.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A001 - Boot/Init and Shutdown 8 POWER UP SEQUENCE CHECKS Remove Generator Cabinet covers as required for access to the main circuit breaker in the MDR, the Generator circuit breaker, the Conditioner, and to the pushbuttons controlling power to the Conditioner and the Detector. 8-1 Preliminary Power-Up sequence check Start this sequence with the MDR and Generator circuit breakers switched OFF (as described for the Complete power OFF state checks above). 1. Switch the Generator circuit breaker ON. OK NOT OK 2. Switch the MDR circuit breaker ON. 3. Press the Control Station ON button on the Generator Cabinet; The button lights and power is supplied to the Control Station; check by switching the Light Box on. 4. Press the CONDITIONER ON push button at the top of the MDR; the button lights and the Conditioner starts. 5. Press the UPS ON push-button on the Generator Cabinet for at least one second; the AWS starts up (see VF Job Card UPS Battery if you suspect a problem with the UPS). 6. The Login prompt appears on the AWS monitor within 90 seconds of switchon. At the Login: prompt, enter sdc. At the Password prompt, press the key. The browser application begins to load and the AWS login sceen appears. ! Notice: At this point of the sequence, communication errors between AWS and the Senographe will appear because the Senographe is not yet switched ON. This is normal and does not imply any problem. 7. Press the GANTRY ON push-button in the MDR; the button lights. 8. Press the GANTRY OFF push-button in the MDR; the light goes out. 9. Shut the system down by clicking the System Off button on the Browser window; wait for complete shut down. The system is now in the normal switched-off state, ready for the normal power up sequence (below). Chapter 9 Page no. 1732 JC-CHK-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A001 - Boot/Init and Shutdown 8-2 Normal power UP sequence check Start this sequence with the system in the normal switched-off state (above). 1. Press the power ON push-button I on the X-ray Console. Power is applied to all parts of the system: 2. .The Gantry Console central LCD panel displays default settings for kV and mAs, and displays a message indicating temporary communications errors. 3. The AWS Monitor LED lights. On the UPS the orange LEDs flash during the selftest process, then the On-line LED (green) is lit. No red LED should be lit and no LEDs should continue flashing. OK NOT OK 4. The Login prompt appears on the AWS monitor within 90 seconds of switchon. Log in as described above. 5. The pop-up message All devices are OK appears on the AWS monitor. 6. The Gantry Console displays the two following messages: S70 Wrong application selected and S34 Select Laterality; these messages are normal, because an exam has not been started and no laterality has been selected. 7. The Browser window appears on the AWS monitor. Within about 5 minutes of switching on, it should be possible to use the Start Exam button in the Worklist window (see the Senographe DS Operator Manual). 9 POWER ON STATE CHECKS These checks confirm normal operation after the normal power up sequence (above); 1. The Browser window appears on the AWS monitor. 2. None of the UPS front panel LEDs are flashing; the On–line LED (green) is lit. 3. The Conditioner is running (pump audible and no conditioner error messages displayed). Page no. 1733 JC-CHK-A-001.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A001 - Boot/Init and Shutdown 10 NORMAL POWER OFF SEQUENCE CHECKS 1. Click the System Off button in the Browser window. 2. A message appears, requesting confirmation of the shutdown request. confirm by clicking OK. 3. After a few minutes, the Console display goes blank. OK NOT OK 4. The Control Station and AWS system perform the shut down sequence, which takes approximately two minutes. The normal shut-down message appears on the monitor: System is down. System will power off within 30 seconds; do NOT reboot now! (if system does not turn off, switch off UPS manually. If at any time the Ups does not shut down after the System Off request, the UPS should be turned off by pressing the Control Station OFF button at the front of the Generator Cabinet. 5. Within about two minutes of confirmation of the shutdown request, the Control Station system is switched off and the Gantry/Generator system is switched off (check again at the X-ray Console). 6. No LED lit or flashing on the UPS. 7. Check that the conditioner continues to operate; check that the Control Station ON button (at the front of the Generator Cabinet), and the CONDITIONER ON button (inside the MDR) are still lit. 11 THERMAL CUTOUTS Two thermal cutouts are fitted in the Generator Cabinet, one in the autotransformer, and the other on the 200PL1 board. If either of these cutouts operates, the system shuts down, it is impossible to restart the system; the Xray Console ON push-button has no effect. The system will not start until it has cooled and the cutout has recovered. • Autotransformer cutout. Operates at 120°C; the OFF button on the Main Supply Rack remains lit, but it is impossible to restart the system. Recovery time is one to two hours. • 200PL1 board cutout. Operates at 110°C; the OFF button on the Main Supply Rack is not lit; it is impossible to restart the system. Recovery time is about half an hour. Chapter 9 Page no. 1734 JC-CHK-A-001.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A001 - Boot/Init and Shutdown 12 SYSTEM COMPONENT RESET It may occasionally be necessary to reset one or more components of the system. This usually involves switching the component(s) off and on again. The following table shows suggested switch-off points, classified for use by operating personnel or by FEs (i.e., trained personnel with access to system cabinets). TABLE 1 - RESET OPERATIONS Component(s) Operator F.E. Comments Whole system Hospital supply ON/OFF switch Hospital supply ON/OFF switch Conditioner Hospital supply ON/OFF switch Conditioner OFF button inside MDR Gantry and Generator OFF/ON at X-ray Console Generator Circuit breaker in Generator Cabinet Also resets the Detector and its power supply Detector and its power supply OFF/ON at X-ray Console Detector OFF button inside MDR OFF/ON at X-ray Console also resets the Gantry and Generator Control Station and all contents (AWS system, monitor, IDC, modem, CD-R/W, light box) Click on System Off button in Browser. Wait two minutes for UPS shutdown Control Station OFF button on side of Generator cabinet System Shutdown includes shutdown of Gantry and Generator. UPS Click on System Off button in Browser. Wait two minutes for UPS shutdown Control Station OFF button on side of Generator cabinet System Shutdown includes shutdown of Gantry and Generator. IDC Click on System Off button in Browser. Wait two minutes for UPS shutdown IDC reset button at rear of the IDC. See Caution below. System Shutdown includes shutdown of Gantry and Generator. AWS Click on System Off button in the Tool kit menu. Reboot Open a command window; type halt. Then type reset. CAUTION It is recommended that the IDC should not be booted or reset by itself without a complete system shutdown/power on. If the IDC is rebooted, a minimum interval of two (2) minutes must be left before booting it again. Booting the IDC twice within two minutes may seriously degrade the detector. Page no. 1735 JC-CHK-A-001.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A001 - Boot/Init and Shutdown This page is blank. Chapter 9 Page no. 1736 JC-CHK-A-001.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A003 - UPS Batteries Job Card CHK A003 - UPS Batteries 1 Chapter 9 SUPPLIES None 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 5 minutes for UPS function check and 60 minutes for battery recalibration 4 SAFETY PRECAUTIONS .None 5 PREREQUISITES None 6 UPS FUNCTION CHECK The LEDs and control buttons of the UPS front panel may be observed and accessed through the transparent panel at the front of the Control Station. ON/TEST BUTTON LOAD INDICATOR (5 LEDS) STATUS LEDS: A - SMART TRIM (INPUT HIGH) B - ON LINE C - SMART BOOST (INPUT LOW) D - OVERLOAD E - ON BATTERY F - REPLACE BATTERY CHARGE/LINE VOLTAGE INDICATOR (5 LEDS) A D B E C F OFF BUTTON ! Notice: If you intend to re-calibrate the battery capacity indicator (procedure described below), you should do this before the function check, to avoid an additional delay while the battery recharges. Proceed as follows to carry out the function check: 1. With the system powered on as normal, observe the state of the front panel LEDs: a. The On Line LED (B) should be lit. b. If any of the remaining five status LEDs (A, C, D, E, F, G) are lit, the cause should be investigated. c. The Load Indicator LEDs indicate the power being drawn from the UPS as a percentage of the rated capacity. Normally, four LEDs or less should be lit. d. The Charge/Line Voltage LEDs indicate the current state of battery charge. With all five LEDs lit, the battery is fully charged. When the lowest LED flashes, the battery can supply less than two Page no. 1737 JC-CHK-A-003.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A003 - UPS Batteries minutes of run time; you must wait for the battery to recharge before using the system. 2. Start a UPS self test; press and hold the ON/TEST button until a beep is heard and the On Line LED (B) flashes. During the test the UPS briefly supplies the load from the battery; the On Battery the test passes, the On Battery LED goes out and the On Line LED LED (E) is lit. If (B) again lights steadily. If the test fails, the UPS returns to on-line status, but the Replace Battery LED (F) is lit. The cause should be investigated. 3. To check the input voltage (hospital supply), press and hold the ON/TEST button for at least four seconds (this will start a self test as above): The Charge/Line Voltage LEDs now indicate the input voltage status; normally two, three, or four LEDs should light. If all five LEDs are lit, the input is more than 247 V; if one LED is lit or no LEDs are lit, the input is less than 213 V. 7 BATTERY CAPACITY RE-CALIBRATION About once a year, it may be desirable to re-calibrate the battery capacity indicator. The procedure, including battery recharge, takes about one hour ! Notice: It may not be possible to start this procedure immediately after the function check described above, because it requires the battery charge to be 100% of capacity. 7-1 Battery Capacity Re-Calibration on V1/V2 Control Stations 1. From the Service Desktop, click the Diagnostics button , then the UPS button. 2. To prevent the system from being shut down during the calibration process, select Configuration/ Event Actions, and then the UPS Battery is Discharged event; remove the check mark from the Shutdown Server box. 3. Note that the calibration process will not start if the battery charge is less than 100%. To display Battery Capacity (in place of Run Time Remaining), select Configuration/Monitoring Preferences, and select the parameter to be displayed in the left hand graphical bar of the PowerChute interface. 4. Start the calibration process by selecting Diagnostics/Initiate run Time Calibration. 5. Once started, the calibration process continues until battery capacity falls to 25% (the time from 100% to 25% is about 10 minutes). With the AWS system powered off and power applied to the UPS, the battery takes 45-60 minutes to recharge. 6. Before returning the system to normal operation, you must ensure that it will be shut down if battery capacity is low: - EITHER: In the PowerChute interface menu, select Configuration/Event Actions, and select the UPS Battery is Discharged event; click the Shutdown Server box to restore the check mark. - OR: Log in as root in a command window; execute the command ups stop Chapter 9 Page no. 1738 JC-CHK-A-003.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A003 - UPS Batteries 7-2 Battery Capacity Re-Calibration on V3/V4 Control Stations 1. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 2. Change to the /export/home/insite/browser directory, by entering: cd /export/home/insite/browser 3. Connect to the UPS web-based diagnostics, by entering: mozilla-bin http://localhost:3052 4. At the login page that appears, specify root for the username and root for the password. 5. Note that the calibration process will not start if the battery charge is less than 100%. To display Battery Capacity , select from the left menu Smart-UPS 750 RM ->Status. 6. Prevent the system from being shut down during the calibration process, do the following: a. Select the left menu Event, then Actions, and click on the Battery discharged event. b. Under the Command file item, uncheck the Enable command file execution checkbox. c. Under Shutdown, uncheck the Initiate Shutdown Sequence checkbox. d. Click on the Apply button. e. Click on the Insufficient Runtime Available event. f. Under Shutdown uncheck the Initiate Shutdown Sequence checkbox. g. Click on the Apply button. 7. Start the calibration process. To do this, select in left menu Smart-UPS 750 RM->Select Diagnostic, under item Initiate diagnostic select diagnostic action Runtime calibration, then click the Apply button. 8. During the test and calibration process, the following events occur: - The ON line led (B) is off, and the On Battery led (E) is on. - The UPS beeps. - The UPS charge indicator decreases. Check the test status by clicking on left menu Diagnostics under Smart-UPS 750 RM. Wait until the Initiate Diagnostics staus changes from (Runtime calibration in progress) to (Runtime calibration currently unavailable). Note: Once you launch a test, the Runtime calibration is not available because battery is in the process of being discharged. When the Runtime Calibration test is complete the Runtime Calibration date is updated. 9. Shutdown the AWS system as follows: a. Select menu Shutdown now under Protected System "Shutdown now". You may need to login again (as username root, password root) if session has expired. b. Change the Begin OS Shutdown Sequence In value to 1 second. c. Select the UPS Shutdown type, Manual Restart. d. Click on the Apply button. e. Acknowledge the shutdown. With the AWS system powered off and power applied to the UPS, the battery takes 45-60 minutes to recharge. Page no. 1739 JC-CHK-A-003.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A003 - UPS Batteries 10. Wait until the UPS battery is fully recharged (i.e. when the 5 charge LEDs on the UPS are illumintated. Once the UPS battery is fully recharged, restore the parameters using the steps below. 11. Power up the Senographe system, and login as usual. The from behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 12. Change to the /export/home/insite/browser directory, by entering: cd /export/home/insite/browser 13. Connect to the UPS web-based diagnostics, by entering: mozilla-bin http://localhost:3052 14. At the login page that appears, specify root for the username and root for the password. 15. Use the UPS web-based interface to restore the UPS paramters as follows: a. Select the left menu Event, then Actions, and click on the Battery discharged event. b. Under the Command file item: - check the Enable command file execution checkbox - select in list /opt/APC/PowerChuteBusiness/Agent/cmdfiles/batteryDischarged.sh - enter a value of 3 seconds for Command file Execution Duration c. Under Shutdown, check the Initiate Shutdown Sequence box. d. Click on the Apply button. e. Click the Insufficient Runtime Available event. f. Under Shutdown, check Initiate Shutdown Sequence. g. Click on the Apply button. Chapter 9 Page no. 1740 JC-CHK-A-003.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A004 - DICOM Printer Adjustments and Checks Job Card CHK A004 - DICOM Printer Adjustments and Checks 1 Chapter 9 SUPPLIES None 2 TOOLS Densitometer 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 10 minutes 4 SAFETY PRECAUTIONS. None 5 PREREQUISITES The printer must be correctly calibrated. 6 PROCEDURE 6-1 Preparation and Print 1. Install the SMPTE pattern (together with the Test_pattern pattern). To do this, right mouse click on the Browser background and from the Root Menu that appears, select Service Tools > Install SMPTE. Page no. 1741 JC-CHK-A-004.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A004 - DICOM Printer Adjustments and Checks 2. Select the FFDM Printer patient from the patient list in the Browser. 3. Click the Review Exam button to open a review exam for the selected FFDM Printer. A review exam for the FFDM Printer appears (similar to the following). Auto-windowing options WW and WL values 4. If the display WW and/or WL values have been changed, select the Standard auto-windowing option to return them to the default values of WW =1500 and WL = 2000. Chapter 9 Page no. 1742 JC-CHK-A-004.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A004 - DICOM Printer Adjustments and Checks 5. Click the PRINT button . 6. From the Print Request window that appears, select the DICOM printer you want to check in the list of DICOM printers, then click on Printing Properties .... 7. In the Printer properties window that appears, select Blue film for the Media type, Processor for the Destination, and Portrait for the Film orientation. Then click Save to save the settings and Done to return to the Print Request window. 8. Back in the Print Request window, click Print. Page no. 1743 JC-CHK-A-004.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A004 - DICOM Printer Adjustments and Checks 9. The image is sent to the printer. Check the quality of the printed image as described below. CAUTION Make sure that the SMPTE pattern appears with WW =1500 and WL = 2000 for the image quality tests. 6-2 • • Image Quality checks Examine the printed image (illustrated below). Check the image quality according to the points listed. - Verify continuity of the white diagonal lines [1]. Check that they do not show steps. In the two white squares [2] the vertical and horizontal lines must be well separated for good resolution. In the large light gray square, check that the arc [3] is not duplicated. The small black square [4] within the larger square must not be surrounded by a white line. The small white square [6] within the larger square, must not be surrounded by a black line. Check that the optical density is the same everywhere in the long grey rectangle (+7%) [5]. Chapter 9 Page no. 1744 JC-CHK-A-004.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A011 - Check kVp settings Job Card CHK A011 - Check kVp settings 1 Chapter 9 SUPPLIES None 2 • TOOLS kVp meter. The kVp meter must be in good condition and possess valid certification. Suitable meters are: - Radcal 4083 kVp meter - RMI 232 kVp meter - Keithley 35080B kVp meter Note: The calibration curve attached to the meter (obtained during periodic recalibration of the meter) must be used to correct the meter reading throughout this procedure. Note: The Keithley 35080B kVp meter is not recommended for use in Europe It does not meet the European accuracy requirement of 3%. • Standard 19 X 23 Compression Paddle for positioning the kVp meter close to the Tube Head • Detector Protection Plate (used to protect the detector from the possibility of falling objects) • Radiation Protection Plate (used to protect the detector from excessive exposure to X-rays) 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 5 minutes 4 SAFETY PRECAUTIONS The procedures in this Job Card produce X-rays. Ensure that you take appropriate precautions when operating with X-rays (for example, stay behind the radiation screen during an X-ray exposure). 5 PREREQUISITES None 6 PROCEDURE The procedures described below are designed to verify that the values of kVp delivered by the equipment correspond to the values selected by the operator. Page no. 1745 JC-CHK-A-011.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A011 - Check kVp settings 6-1 Preparation 1. Use adhesive tape (or similar) (1) to attach the Radiation Protection Plate (2) to the bottom side of the Standard 19 x 23 Compression Paddle as shown below. 1 2 Note: Ensure the adhesive tape is attached in such a way that when it is removed, it will not leave glue residue on the Compression Paddle. ! Notice: The Radiation Protection Plate will protect the detector from excessive exposure to X-rays. Before proceeding to make exposures, ensure that the detector has been protected from excessive X–ray doses as instructed above. 2. Remove the Bucky, and install the Detector Protection Plate (3) on the detector. 3. Install the Standard 19 x 23 Compression Paddle updside down, so that the Radiation Protection Plate is approximately below the bottom of the Tube Head as follows: • 205 mm (8.07 inches) for the RMI 232 kVp meter and Keithley 35080B kVp meter • 155 mm (6.10 inches) for the Radcal 4083 kVp meter 205 mm for RMI 232 and Keithley 35080B 155 mm for Radcal 4083 4 Chapter 9 Page no. 1746 JC-CHK-A-011.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A011 - Check kVp settings The purpose here is simply to reduce the distance between the kV peak meter and the X-ray source - see applicable documentation for minimum acceptable distance from X-ray source, if any. Select the appropriate procedure according to the meter to be used, as follows: • Procedure - RMI 232 kVp meter on page 1748 • Procedure - RADCAL 4083 kVp meteR on page 1750 • Procedure - Keithley 35080B KVp meter on page 1752 Page no. 1747 JC-CHK-A-011.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A011 - Check kVp settings 7 PROCEDURE - RMI 232 KVP METER 7-1 kVp meter calibration 1. Note the meter identification number and date of most recent calibration: kVp meter identification number Date of calibration: (dd/mm/yy) 2. Note the required kV correction values by copying CP row values from the meter calibration curve. Measured kVp 26 28 30 32 kV Correction value 7-2 Position the meter 1. Ensure that the Radiation Protection Plate is 205 mm (8.07 inches) below the bottom of the Tube Head. 2. Place the kV peak meter on the Radiation Protection Plate located on the Standard 19 x 23 Compression Paddle. 3. Use the Senographe light centering device to center the kV peak meter target within the X-ray zone. Chapter 9 Page no. 1748 JC-CHK-A-011.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A011 - Check kVp settings 7-3 kVp measurements - RMI 232 kVp meter Make a series of kVp measurements, as follows: 1. Set the X-ray field to the smallest size greater than the kVp meter measurement area shown on the meter. 2. Switch on the meter. Set the waveform selector to CP (constant potential). 3. Select manual exposure mode, and set the X-ray parameters to: Mo track/Mo filter, 50 mAs, LF 4. Make exposures at the Selected kVp values shown in the table below. For each exposure note the Measured kVp value shown on the meter: Focus mAs Selected KVp (S) 0.3 50 0.3 Measured KVp Corrected KVp Upper Limit (S+3%) Lower Limit (S-3%) 26 26.78 25.22 50 28 28.84 27.16 0.3 50 30 30.90 29.10 0.3 50 32 32.96 31.04 Result Pass/Fail 5. Use the kVp correction values noted above to calculate and enter Corrected kVp values. 6. For the check to be passed, each of the Corrected kVp values must lie between the specified Upper and Lower Limits. 7. If the check fails at any value, repeat the complete procedure. 8. If the repeated check fails again, kVp calibration is necessary. Perform the procedure described in Job Card CAL A011 - Calibration of kV Scale Factor on page 1667. Page no. 1749 JC-CHK-A-011.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A011 - Check kVp settings 8 PROCEDURE - RADCAL 4083 KVP METER 8-1 kVp meter calibration • Note the meter identification number and date of most recent calibration: kVp meter identification number Date of calibration: (dd/mm/yy) 8-2 Position the meter 1. Ensure that the Radiation Protection Plate is 155 mm (6.10 inches) below the bottom of the Tube Head. 2. Use the Senographe light centering device to center the kV peak meter target within the X-ray zone. Chapter 9 Page no. 1750 JC-CHK-A-011.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A011 - Check kVp settings 8-3 kVp measurements - RADCAL 4083 kVp meter Make a series of kVp measurements, as follows: 1. Set the X-ray field to the smallest size greater than the kVp meter measurement area. 2. Switch on the meter. 3. Select manual exposure mode, and set the X-ray parameters to: Mo track/Mo filter, 50 mAs, LF 4. Make exposures at the Selected kVp values shown in the table below. For each exposure note the Measured kVp value shown on the meter: Focus mAs Selected KVp (S) 0.3 50 0.3 Measured KVp Upper Limit (S+3%) Lower Limit (S-3%) 26 26.78 25.22 50 28 28.84 27.16 0.3 50 30 30.90 29.10 0.3 50 32 32.96 31.04 Result Pass/Fail 5. For the check to be passed, each of the Measured kVp values must lie between the specified Upper and Lower Limits. 6. If the check fails at any value, repeat the complete procedure. 7. If the repeated check fails again, kVp calibration is necessary. Perform the procedure described in Job Card CAL A011 - Calibration of kV Scale Factor on page 1667. Page no. 1751 JC-CHK-A-011.fm Chapter 9 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A011 - Check kVp settings 9 PROCEDURE - KEITHLEY 35080B KVP METER ! Notice: This meter is not recommended for use in Europe; it does not meet the European accuracy requirement of 3%. 9-1 • kVp meter calibration Note the meter identification number and date of most recent calibration: kVp meter identification number Date of calibration: (dd/mm/yy) 9-2 Position the meter 1. Ensure that the Radiation Protection Plate is 205 mm (8.07 inches) below the bottom of the Tube Head. 2. Place the kV peak meter on the Radiation Protection Plate located on the Standard 19 x 23 Compression Paddle. 3. Use the Senographe light centering device to center the kV peak meter target with the X-ray zone. Chapter 9 Page no. 1752 JC-CHK-A-011.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A011 - Check kVp settings 9-3 kVp measurements - Keithley 35080B KVp meter Make a series of kVp measurements, as follows: 1. Set the X-ray field to the smallest size greater than the kVp meter measurement area shown on the meter. 2. Switch on the meter. 3. Select manual exposure mode, and set the X-ray parameters to: Mo track/Mo filter, 50 mAs, LF 4. Make exposures at the Selected kVp values shown in the table below. For each exposure note the Measured kVp value shown on the meter.: Focus mAs Selected KVp (S) 0.3 50 0.3 Measured KVp Upper Limit (S+0.5 kV) Lower Limit (S-0.5 kV) 26 26.50 25.50 50 28 28.50 27.50 0.3 50 30 30.50 29.50 0.3 50 32 32.50 31.50 Result Pass/Fail 5. For the check to be passed, each of the Measured kVp values must lie between the specified Upper and Lower Limits. 6. If the check fails at any value, repeat the complete procedure. 7. If the repeated check fails again, kVp calibration is necessary. Perform the procedure described in Job Card CAL A011 - Calibration of kV Scale Factor on page 1667. Page no. 1753 JC-CHK-A-011.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A011 - Check kVp settings This page is blank. Chapter 9 Page no. 1754 JC-CHK-A-011.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A013 - Check mA and mAs settings Job Card CHK A013 - Check mA and mAs settings 1 Chapter 9 SUPPLIES None 2 • • 3 TOOLS Radiation Protection Plate Meter for measurement of mAs. The meter used must be in good condition and possess valid certification. Suitable meters are: - Fluke 87 multimeter - Keithley 35035 mAs meter - GS Poner 165 mA-mAs meter REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes 4 SAFETY PRECAUTIONS The procedures in this Job Card produce X-rays. Ensure that you take appropriate precautions when operating with X-rays (for example, stay behind the radiation screen during an X-ray exposure). 5 • PREREQUISITES The Generator covers must have been removed for access to the kV/mA board 701-PL1 on the HV tank unit. Refer to Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513. Page no. 1755 JC-CHK-A-013.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A013 - Check mA and mAs settings 6 PROCEDURE The procedures described below are designed to verify that the values of mA and mAs delivered by the equipment correspond to the values selected by the operator. CAUTION DO NOT touch potentiometer P1 on generator kV/mA board 701-PL1 at any point in this procedure. 6-1. Preparation 1. Switch off the system. 2. Remove the strap between test points MES_M_NEG and MES_M_POS of generator kV/mA board 701-PL1. MES_M_NEG Strap MES_M_POS 3. Connect a milliammeter between test points MES_M_NEG and MES_M_POS of generator kV/mA board 701-PL1. 4. Place the Radiation Protection Plate on the Bucky (to protect the detector). 5. Switch on the system. 6. Configure the SetUp menu to display exposure parameters: select SETUP/GENE/INSTAL/GENE/ CONFIG/DISP/YES. Chapter 9 Page no. 1756 JC-CHK-A-013.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A013 - Check mA and mAs settings 6-2 Check mA displayed on the X-ray Console 1. Go to the medical application and use the parameters shown in the following table to make an exposure. 2. Note the Nominal mA value (N) displayed on the X-ray Console, and the Measured mA value (M) on the meter. Calculate the values N +5% and N -5%. Filter/Track/ Focal spot kV Selected mAs Mo/Mo/LF 30 100 Nominal mA (N) on Console Measured mA (M) N+5% N-5% Test result Pass/Fail 3. For the check to pass, the Measured mA value (M) must be within ±5% of the Nominal mA value (N). 4. If the check fails, perform the calibrations described in Job Card CAL A009 - X-Ray Tube mA Measurement on page 1663 and Job Card CAL A012 - X-Ray Tube Heater Current on page 1673. 6-3 Check mA calibration 1. Make four exposures, using the parameters shown in the following table. 2. For each exposure, note the Measured mA value (M) on the meter. Filter/Track/ Focal spot kV Mo/Mo/LF 30 Mo/Mo/SF Selected mAs Measured mA (M) Expected Nominal mA (N) N-5% N N+5% 63 95 100 105 30 63 38 40 42 Rh/Rh/LF 30 63 58.9 62 65.1 Rh/Rh/SF 30 63 33.25 35 36.75 Test result Pass/Fail 3. For the check to pass, each Measured mA value (M) must be within ±5% of the corresponding Expected Nominal mA value shown (N). 4. If the check fails, there is a system error which must be corrected. 6-4 Check mAs calibration 1. Follow the instructions of section 6-1 Preparation, but this time connect an mAs meter in place of the milliammeter. 2. Use the parameters shown in the following table to make an exposure. 3. Note the meter reading Measured mAs. Filter/Track/ Focal spot kV Selected mAs Mo/Mo/LF 30 63 Measured mAs Lower limit Upper limit (63 mAs -5%) (63 mAs +5%) 59.9 Test result Pass/Fail 66.2 4. For the check to pass, the meter reading Measured mAs must be between the Lower and Upper limits shown. 5. If the check fails, there is a system error which must be corrected. Page no. 1757 JC-CHK-A-013.fm Chapter 9 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CHK A013 - Check mA and mAs settings This page is blank. Chapter 9 Page no. 1758 JC-CHK-A-013.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Long Term Shutdown Procedures CHAPTER 10 LONG TERM SHUTDOWN PROCEDURES This chapter contains important information which will be required if the Senographe system must be stored or left without power for a long period. Page no. 1759 Chap-Shutdown.fm Chapter 10 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Long Term Shutdown Procedures This page is blank. Chapter 10 Page no. 1760 Chap-Shutdown.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CARE A001 - Detector protection during system shutdown Job Card CARE A001 - Detector protection during system shutdown Chapter 10 1 • HOSPITAL/SYSTEM SHUTDOWN The Digital Detector used in the Senographe system contains components which are extremely sensitive to variations of temperature and humidity. Any large or long term variation in temperature or humidity may cause permanent damage to the detector. In normal operation, including normal shut-down, the detector is protected from damage by the Conditioner, which controls the temperature and internal humidity of the detector within close limits. If the system must be completely shut down for any reason, for example if the hospital department is closed for a vacation period, special precautions must be taken to avoid damage to the detector. • 2 DETECTOR PROTECTION DURING SHUTDOWN There are two possible methods of protecting the detector if the normal system power must be switched off during a prolonged shutdown: • Connect the Conditioner to a normal power outlet and leave it switched on. This ensures that power is returned after any brief power outages (due to storms, etc.). If the Generator system is left on standby, it does not start up automatically after a power outage, and power is switched off permanently • Disconnect and drain the cooling circuit as much as possible. Ensure that no coolant is left in the Detector or in the Conditioner. Use a syringe or similar tool if necessary. ! Notice: When the Detector is not protected by connection to a functional Conditioner, the following storage conditions must be respected: Humidity: 10% min., 50% max. (up to 95% R.H. can be tolerated for less than two weeks). Temperature: +10°C (50°F) min. to +25°C (77°F)max. (-10°C (14°F) min. to +50°C (122°F) max. for less than one day). Atmospheric pressure: 500 hPa min., 1060 hPa max. Page no. 1761 JC-CARE-A-001.fm Chapter 10 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card CARE A001 - Detector protection during system shutdown This page is blank. Chapter 10 Page no. 1762 JC-CARE-A-001.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Planned Maintenance Procedures CHAPTER 11 PLANNED MAINTENANCE PROCEDURES 1 INTRODUCTION This chapter contains recommendations for planned maintenance of the Senographe DS. Page no. 1763 Chap-Planned Maintenance.fm Chapter 11 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Planned Maintenance Procedures This page is blank. Chapter 11 Page no. 1764 Chap-Planned Maintenance.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Scenario PM A001 - Planned Maintenance Steering Guide Scenario PM A001 - Planned Maintenance Steering Guide 1 Chapter 11 CONTEXT This scenario is to be used in planning and performing planned maintenance visits (PM visits). • Actions required in preparation for each PM visit are described in section 2 Actions prior to PM visit. • Actions to be carried out on-site during each PM visit are listed in the tables in sections 4 PM Task Schedule (Visits 1-6) on page 1769. The tables list each of the recommended on-site planned maintenance tasks. For each task, they give the recommended frequency (Int.; interval between tasks in months) and the expected duration (Drn.; time in minutes) • PM visits must be made at six-monthly intervals. The tables show a suggested sequence of tasks to be performed at successive PM visits, in columns numbered from1 through 6. For each visit an "X" in the column indicates that the corresponding task should be performed. • The total time required for each PM visit depends upon the tasks scheduled and any additional work, such as FRU replacements, calibrations, etc., found to be required. The schedules proposed take account of the estimated time for each task, so as to balance the times required for each visit. • The sums of estimated times for tasks specified at each visit are shown here: PM Visit no. Total time (hours) • • 1 2 3 4 5 6 6.4 6.7 6.4 6.7 6.4 7.1 If the customer has recently performed IQ-related tasks, you do not need to re-perform these tasks during the PM visit. Some local regulations may require you to peform additional PM tasks. Ensure you follow your local regulations to perform additional PM tasks as necessary. Page no. 1765 SC-PM-A-001.fm Chapter 11 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Scenario PM A001 - Planned Maintenance Steering Guide 2 • ACTIONS PRIOR TO PM VISIT Check that any applicable mandatory FMIs have been carried out. Refer to Product history and compatibility on page 51.The following list may not be complete: FMI Required Applied FMI 12083 - Reliability for FB images in Stereotaxy FMI 12075 - Safety : AWS 43.10/53.10 • Carry out the following tasks in preparation for the visit: Task Title Task Definition Obtain site status information and error logs Job Card PM A101 - Site Status: p. 1773 Analyze AWS Error Codes ERR SUB A005 - AWS Error Messages: p. 935 Analyze IDC Error Codes ERR SUB A007 - IDC Error Messages: p. 937 Analyze Gantry Error Codes ERR SUB A003 - Gantry Error Messages: p. 851 Analyze Generator Error Codes ERR SUB A001 - Generator Error Messages: p. 831 Chapter 11 Page no. 1766 SC-PM-A-001.fm 3-1 Supplies and consumables required per PM visit The following table lists the supplies and consumables required for each PM visit. 1 2 3 4 5 6 GE Healthcare SUPPLIES AND SPECIAL TOOLS PER PM VISIT Revision 1 SC-PM-A-001.fm 3 Supplies Lithium battery (for Generator CPU board) X AWS (U20) Motherboard Battery (V3 Control Stations only) X X X Consumables Blank DOS formatted HD 3.5 floppy disk or blank CD-R X Lubricant X X X Grease (for Lift and Rotation) X X X X X X X X X X X HV Oil X X X X X X X X X Roll of adhesive tape X X X X X X Senographe DS Chapter 11 Scenario PM A001 - Planned Maintenance Steering Guide Page no. 1767 Coolant kit Service Information and Procedures Class A 2385072-16-8EN HV Grease 1 kVp meter 2 3 X 4 5 X 6 X Purge Tool X X X X X X Spirit Level X X X X X X Protractor X X X X X X Mammography compression scale with digital display X X X X X X Meter(s) for measurement of mA and mAs (Fluke 87 multimeter, Keithley 35035 mAs meter, GS Poner 165 mA-mAs meter) X X X Multimeter (Fluke 87) X X X X X X HV unit/cable adaptor X X X X X X X X X Page no. 1768 Mag Stand Simulator X X X X X X Flat Field Phantom (25mm acrylic) X X X X X X ACR standard phantom X X X X X X IQST Standard Phantom X X X X X X RADCAL Dosimeter X X X 6M ionization chamber (6cc) X X X Dosimeter support with Radiation Protection Plate X X X Radiation Protection Plate X X X X X X Detector Protection Plate X X X Two sheets of 0.2 mm and 0.5 mm thick pure aluminium X X X Standard 19 x 23 compression paddle X X X X 24 x 30 cm mammographic cassette with film X X X 1-inch thick attenuator sheet of acrylic or a 1–2 cm thick sheet of BR-12 X X X One coin, GAFCHROMIC® XR-M and Aluminium attenuator plate X X X Siemens Serial Spot Meter (If Stereo or 2D Biopsy Optical Localizer option exists) SC-PM-A-001.fm Vacuum Cleaner X X X X X X X X X X X X X X Senographe DS Set of acrylic plates Service Information and Procedures Class A 2385072-16-8EN Mag Stand or Mag Stand Simulator GE Healthcare The following table lists the special tools required for each PM visit. Revision 1 Special tools required per PM visit Scenario PM A001 - Planned Maintenance Steering Guide Chapter 11 3-2 Note: Some of the tasks listed in this schedule may overlap with similar tasks required by your local regulations. If this is the case you can skip these particular tasks and perform the tasks required by your local regulations instead. Task Title Task Definition Int. Drn. mth. min. 1 2 3 4 5 6 Perform a general inspection of the entire system. See Job Card PM A155 - General System Inspection Checks on page 1775. 6 10 X X X X X X Remove Generator Covers. Job Card PHY A042 - Remove/Reinstall Generator Covers: p. 513 6 5 X X X X X X Clean Conditioner Air Filter Job Card PM A429 - Conditioner Air Filter Cleaning: p. 1807 6 5 X X X X X X Check and top-up Conditioner coolant Job Card PM A428 - Conditioner Coolant Level Check and Top-up: p. 1805 6 5 X X X X X X Change Generator CPU Lithium Battery Job Card D/R A402 - Generator CPU Battery: p. 1549 36 25 Check HV Unit Job Card PM A407 - Check HV Unit: p. 1801 12 5 X X X Check Half Value Layer (HVL) Job Card CAL A046 - Half-Value Layer Measurement: p. 1703 12 10 X X X Check kVp settings Job Card CHK A011 - Check kVp settings: p. 1745 12 5 X X X Check mA and mAs settings Job Card CHK A013 - Check mA and mAs settings: p. 1755 12 30 X X X Reinstall Generator covers. Job Card PHY A042 - Remove/Reinstall Generator Covers: p. 513 6 5 GE Healthcare PM TASK SCHEDULE (VISITS 1-6) Revision 1 SC-PM-A-001.fm 4 PM Visit no. Inspection: General system inspection checks Generator/Tube: X X X X X Senographe DS Chapter 11 Service Information and Procedures Class A 2385072-16-8EN X Scenario PM A001 - Planned Maintenance Steering Guide Page no. 1769 X Drn. PM Visit no. mth. min. 1 2 3 4 5 6 Gantry: 12 20 X X Check Breast Thickness Measurement Job Card ELE A015 - Gantry Functional Checks section 6-9 Check Breast Thickness Measurement: p. 581 6 10 X Check Gantry functions Job Card PM A201 - Gantry operational checks: p. 1777 12 10 X X X Check for correct collimation Job Card ELE A028 - Collimation Checks: p. 679 12 20 X X X Check and lubricate Gantry mechanisms Job Card PM A205 - Mechanical checks and lubrication: p. 1779 12 20 X X X Reinstall Gantry covers Job Card PHY A044 - Remove/Reinstall Gantry Covers: p. 523 12 30 X X X Check Manual Compression maximum force. Job Card ELE A017 - Manual Compression Check and Calibration: p. 583 12 10 X X X Check Gantry emergency stop buttons. Check operation of both Gantry emergency stop buttons. Check that all movement of the Ganttry is stopped when either button is pressed. 12 5 X X X Check UPS function Job Card CHK A003 - UPS Batteries section 6 UPS Function Check: p. 1737 6 5 X Recalibrate UPS Battery Capacity Job Card CHK A003 - UPS Batteries section 7 Battery Capacity Re-Calibration: p. 1738 12 10 X Remove Control Station covers Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503 6 10 X Change AWS (U20) Motherboard battery (V3 Control Stations only) Job Card D/R A335 - AWS (U20) Motherboard Battery (V3 Control Stations only) on page 1537 12 15 Clean IDC air filter (only applicable on systems with the Dione 5 IDC) Job Card PM A425 - IDC Air Filter Cleaning on page 1803 6 10 X X X X X X Reinstall Control Station covers Job Card PHY A040 - Remove/Reinstall Control Station Covers on page 503 6 10 X X X X X X X X X X X X Control Station X X X X X X X X X X X X X X X SC-PM-A-001.fm Senographe DS Job Card PHY A044 - Remove/Reinstall Gantry Covers: p. 523 Service Information and Procedures Class A 2385072-16-8EN Page no. 1770 Remove Gantry covers. GE Healthcare Int. Revision 1 Task Definition Scenario PM A001 - Planned Maintenance Steering Guide Chapter 11 Task Title Int. Drn. mth. min. PM Visit no. 1 2 3 4 5 6 Acquisition IQ: Job Card PM A254 - Tube Head Fan Filter Cleaning: p. 1783 6 20 X X X Clean Collimator Job Card PM A255 - Collimator and Tube Head Cleaning: p. 1787 12 45 X X X If Stereo or 2D Biopsy Optical Localizer option exists, calibrate the LCD Monitor Job Card ELE A043 - AWS Monitor Calibration on page 729 12 40 X X X If the 21-inch 3 MP Monitor option exists, check the monitor luminance Job Card PM A300 - 21-inch 3MP Monitor Luminance Checks on page 1793 12 60 X X X IQ Tools Flat Field Test Job Card ELE A032 – IQ Tools Flat Field Test: p. 699 6 30 Calibrate Conversion Factor Job Card CAL A045 - Conversion Factor Measurement: p. 1701 12 8 Check Image Acquisition and ACR Score Job Card ELE A037 - Image Acquisition and ACR Score: p. 705 6 8 Calibrate mAs Non-Linearity (Automatic) Job Card CAL A053 - mAs Non-linearity Calibration: p. 1725 12 8 X X X AOP calibration Job Card CAL A051 - AOP Calibration: p. 1723 12 8 X X X AOP mode and SNR check Job Card ELE A038 - AOP Mode and SNR Check: p. 707 12 15 X X X Job Card ELE A052 - Back-up/Restore Procedure: p. 771 6 10 X X X X X X X X X X X X X Senographe System PM finalization: Backup Senographe parameters X X X X X X Senographe DS Chapter 11 Service Information and Procedures Class A 2385072-16-8EN X X Scenario PM A001 - Planned Maintenance Steering Guide Page no. 1771 Clean Tube Head Fan Filter (for sites with tube head dust reduction kit) GE Healthcare Task Definition Revision 1 SC-PM-A-001.fm Task Title Drn. PM Visit no. mth. min. 1 2 3 4 5 6 Refer to the Service Manual for the option/review station 6 N/A X X X X X X Check site ready for customer Check the cleanliness and presentation of the site; correct any hazards such as trailing cables, etc. 6 10 X X X X X X Check site records Check that all PM documents, records, etc., are stored with the site log book. 6 15 X X X X X X Customer briefing Review the PM visit with the customer. 6 15 X X X X X X PM tasks for options and review stations If the customer has any options or review stations, perform the PM tasks described in the accompanying Service Manual supplied with that option/review station. Completion: GE Healthcare Int. Revision 1 Task Definition Senographe DS SC-PM-A-001.fm Service Information and Procedures Class A 2385072-16-8EN Page no. 1772 Scenario PM A001 - Planned Maintenance Steering Guide Chapter 11 Task Title GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A101 - Site Status Job Card PM A101 - Site Status 1 • • 2 Chapter 11 CURRENT SITE STATUS Before the PM visit, telephone the client to determine and discuss any current issues. Obtain the current site error lists by local or remote downloading, so that they can be analysed in advance. SITE LOGBOOK 1. Review the site Logbook to identify recently applied FMI procedures and last Planned Maintenance Operation Report. 2. Verify the presence of the following log diskettes or log CD-Rs with the site logbook: - PM log - Acquisition log - Review log 3 REVIEW SYSTEM OPERATION WITH CUSTOMER 1. Discuss with customer to find out if there are any specific problems with the system. Make a list of problems and distinguish between problems that can be solved by: - Corrective maintenance - Planned maintenance 2. Propose solution(s) with the customer and come to an agreement on what actions are to be taken. Page no. 1773 JC-PM-A-101.fm Chapter 11 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A101 - Site Status This page is blank. Chapter 11 Page no. 1774 JC-PM-A-101.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A155 - General System Inspection Checks Job Card PM A155 - General System Inspection Checks 1 Chapter 11 SUPPLIES None 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 10 minutes 4 SAFETY PRECAUTIONS None 5 PREREQUISITES None 6 PROCEDURE 6-1 Other General Inspection Checks 6-1-1 Visual inspection of cables Check the appearance of all visible cables and correct hazardous trailing cables in the room. 6-1-2 Visual inspection of equipment Note any signs of damage to covers, monitor support, etc. 6-1-3 Inspect the Radiation Screen Check for breaks or cracks in the glass, gaps or cracks in the frame, and for correct, stable mounting, etc. 6-2 System Cover Checks 6-2-1 Generator cover check Check covers for security and presence of screw caps, and for damage, scratches, etc. 6-2-2 Gantry cover check Check covers for security and presence of screw caps, and for damage, scratches, etc. 6-2-3 Control Station cover check Check covers for security and presence of screw caps, and for damage, scratches, etc. Page no. 1775 JC-PM-A-155.fm Chapter 11 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A155 - General System Inspection Checks This page is blank. Chapter 11 Page no. 1776 JC-PM-A-155.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A201 - Gantry operational checks Job Card PM A201 - Gantry operational checks 1 Chapter 11 SUPPLIES None 2 • • TOOLS Mammography compression scale with digital display Set of acrylic plates 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 10 minutes 4 SAFETY PRECAUTIONS WARNING • Before beginning work on the lift mechanism, shut down the equipment and switch OFF the Senographe hospital supply circuit breaker. Lock it in the OFF position or mark it clearly with a warning sign to prevent others from applying power. NEVER switch off at the UPS except in emergency (risk of data loss). 5 PREREQUISITES None 6 PROCEDURE 6-1 Check lift movement 1. With the compression paddle out of compression, check that all four sets of lift up/down control buttons are operational (check each button for up and down movement of lift). 2. Move arm to its upper and lower limits. Software limits should stop movement. If the software limits fail, optical sensors are used to recognize and stop any movement before impact with mechanical stops.Total one-way movement time (going either up or down) between upper and lower limits should be 8 ±2 seconds. 3. Lift movement should be smooth and progressive; check for any noise which might indicate excessive friction or binding. 6-2 Check Arm Rotation 1. With the compression paddle out of compression, check that all four arm rotation control buttons are operational. For each button, check that light or firm pressure gives the correct rotation, and that rotation stops when the pressure is released. Refer to Job Card ELE A015 - Gantry Functional Checks, section 6-4 Keypad Functional Checks on page 580, for a full list of these checks. 2. Rotate the arm through its full range of +185°/-165°. Check in several positions that the electrical braking is functioning correctly, by pulling on the handles. Page no. 1777 JC-PM-A-201.fm Chapter 11 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A201 - Gantry operational checks 3. Movement should be smooth and progressive; check for any noise which might indicate excessive friction or binding. 4. Check the alignment of angle markings at 0°. 6-3 Check Light Centering Device Press one of the light centering device activation buttons.; check that the device lights for 45 seconds. 6-4 Check Format Control Check that repeated presses on each of the two format control push buttons give the sequence: 1) light centering device lights; 2) first format reduction; 3) second format reduction; 4) full format. 6-5 Check Magnification Sensors 1. With the magnification device removed, the Gantry readout should show a magnification of 1.0. 2. Install the two magnification devices in turn. The Gantry readout should show magnifications of 1.5 and 1.8, according to the device installed. 6-6 Check Paddle Compression 1. Check the compression paddle mounting for signs of cracks or other damage. 2. Verify that both sets of compression/decompression pedals and the manual compression knobs located on the paddle holder all function correctly (i.e., the paddle moves up or down in response to each command). 3. Use the mammo compression scale placed between the Bucky and the compression paddle to check calibration of the compression force display on the Gantry readout. Measure one point at 5 daN and one point at 15 daN. The value on the Gantry readout must agree within ±1 daN. If it does not, performJob Card CAL A048 - Calibration of Compression Force Sensor on page 1709. If the recommended compression measurement tool is not available, this verification can be done by lowering the paddle close to the top surface of the Bucky, installing the magnification device, and connecting a spring dynamometer (calibrated from 0 to 15 kg) between the compression paddle and the magnification device. Chapter 11 Page no. 1778 JC-PM-A-201.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A205 - Mechanical checks and lubrication Job Card PM A205 - Mechanical checks and lubrication 1 • • Chapter 11 SUPPLIES Lubricant Grease (for Lift and Rotation) 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 20 minutes 4 SAFETY PRECAUTIONS WARNING • 5 • • Before working on any Gantry mechanism, shut down the equipment and switch OFF the Senographe hospital supply circuit breaker. Lock it in the OFF position or mark it clearly with a warning sign to prevent others from applying power. NEVER switch off at the UPS except in emergency (risk of data loss). PREREQUISITES The Gantry Column and Compression Arm covers must be removed. Refer to Job Card PHY A044 Remove/Reinstall Gantry Covers on page 523. Release the four hex head screws securing the lower X plate (10 mm open-ended wrench). Page no. 1779 JC-PM-A-205.fm Chapter 11 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A205 - Mechanical checks and lubrication 6 PROCEDURE 6-1 Check and clean the lift mechanism 1. Raise the arm to its maximum height, to facilitate access to the arm mechanism. 2. Switch off system power (see the Warning above). 3. Check for any sign of oil leakage from the gas spring (1). Leakage may indicate the need to change the spring. 4. Use Grease (for Lift and Rotation) to lubricate the thread of the trapezoidal screw (2) and guide rails (3) 5. Check the motor drive belt manually for adequate tension. 6-2 3 1 2 Check and clean the compression mechanism 1. Switch off system power (see the Warning above). 2. Use Lubricant to clean and lubricate the guide rail (1). 3. Check manually with your hands that the Manual Compression Belt (2) is sufficiently tight, that it does not slide, and that the pulleys move when the Manual Compression Belt moves.. 1 2 4 CAUTION If the belt slides from its position, manual compression functions and braking are not available. If there is a motorized compression failure, patient injury can occur. 4. Check the motorized compression drive belt (3) manually for adequate tension. 3 5. Check the full length of the flexible flat cable (4) and its securing ties for any signs of damage. Chapter 11 Page no. 1780 JC-PM-A-205.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A205 - Mechanical checks and lubrication 6-3 Check and lubricate the rotation mechanism 6-3-1 Position the arm for access • Lower the arm for good access to the rotation gears (1). • Switch OFF the Gantry power. 1 CAUTION The following procedures require power to be applied, in order to rotate the arm for access to the gears. After positioning the arm, be sure to switch off all power when you are inspecting or greasing the gears. 6-3-2 Inspect the gears • Locate the meshing teeth of the worm and worm gear (2), and the pair of spur gears (3). 2 3 Page no. 1781 JC-PM-A-205.fm Chapter 11 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A205 - Mechanical checks and lubrication 6-3-3 Locate dry surfaces • Rotate the examination arm between -165° and +185°. Check for dry or partly dry surfaces as shown here (4); this is the visible effect of incorrect greasing 4 ! Notice: Be sure to identify dry or partly dry surfaces before greasing. General greasing may not help! The most critical areas are visible with the arm in the following positions: 0°, 45°, 135°, and 180°. 6-3-4 Greasing • Rotate the arm between the limits of -165° and +185°, to as many positions as required to fully inspect and grease the gears. CAUTION After each movement, switch OFF power while inspecting and greasing. • Apply a light film of Grease (for Lift and Rotation) as required to the teeth of the worm gears and spur gears. • Do not apply excess grease; the quality of greasing is more important than the quantity. • Use a brush to apply grease, so as to avoid direct skin contact as far as possible. • Use a suitable cloth to remove excess grease. Chapter 11 Page no. 1782 JC-PM-A-205.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A254 - Tube Head Fan Filter Cleaning Job Card PM A254 - Tube Head Fan Filter Cleaning 1 Chapter 11 SUPPLIES None 2 APPLICABILITY This Job Card is only applicable if the site has been installed with the Tube Head Dust Reduction Kit. 3 TOOLS Standard Tool Box 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 20 minutes 5 SAFETY PRECAUTIONS WARNING • 6 • • Before working on any Gantry mechanism, shut down the equipment and switch OFF the Senographe hospital supply circuit breaker. Lock it in the OFF position or mark it clearly with a warning sign to prevent others from applying power. NEVER switch off at the UPS except in emergency (risk of data loss). PREREQUISITES If necessary, apply LOTO to switch off the Gantry power. If necessary, remove the tube head covers (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523) to access Collimator and Tube Head. Note: The tube head covers may have already been removed if fan filter cleaning has been performed. Page no. 1783 JC-PM-A-254.fm Chapter 11 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A254 - Tube Head Fan Filter Cleaning 7 PROCEDURE 1. Gently apply pressure to the side of the Fan Filter front cover to remove the Fan Filter front cover and the Fan Filter from the Fan Filter back cover. With modest pressure, the Fan Filter front cover should unclip. 2. Remove the Fan Filter from the Fan Filter front cover. To clean the Fan Filter, shake it until it is free from dust. A clean Fan Filter should like similar to the following. Note: If when you clean the Fan Filter you notice that it is becoming used/perished, the next time you perform the Planned Maintenance order new kit (5394527) and change the filter instead of cleaning it. Chapter 11 Page no. 1784 JC-PM-A-254.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A254 - Tube Head Fan Filter Cleaning 3. Put the Fan Filter back into the Fan Filter front cover. 4. Place the Fan Filter inside the Fan Filter front piece. Position the Fan Filter front piece over the Fan back piece to that the text (1) written in the middle of the Fan Filter front piece is vertical (i.e goes up/ down) and not horizontal (i.e. goes left/right) and so that the arrows (2) are located on the vertical edges and not the horizontal edges. 2 2 3 1 2 2 Note: It is important that the text (1) and arrows (2) are orientated as described above. Having the text (1) and arrows (2) orientated as described above makes the future removal of the Fan Filter front piece simple. 5. Install the Fan Filter front piece and Fan Filter on the Fan Filter back piece by pushing them on to the Fan Filter back piece. The sides of the Fan Filter front piece will clip over the latches (3) of the Fan Filter back piece when you apply modest pressure. Note: If the Fan Filter is damaged, you must order a new dust kit (PN: 5394527). Page no. 1785 JC-PM-A-254.fm Chapter 11 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A254 - Tube Head Fan Filter Cleaning 8 COMPLETION None. Chapter 11 Page no. 1786 JC-PM-A-254.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A255 - Collimator and Tube Head Cleaning Job Card PM A255 - Collimator and Tube Head Cleaning 1 Chapter 11 SUPPLIES None 2 TOOLS • • • Small Static Duster Flat Field Phantom Cotton buds or similar (e.g. a digital camera sensor cleaner as shown below) • • Ethanol Standard Tool Box including a small Pozi screwdriver 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time:45 - 60 minutes 4 SAFETY PRECAUTIONS WARNING • 5 • • Before working on any Gantry mechanism, shut down the equipment and switch OFF the Senographe hospital supply circuit breaker. Lock it in the OFF position or mark it clearly with a warning sign to prevent others from applying power. NEVER switch off at the UPS except in emergency (risk of data loss). PREREQUISITES If necessary, switch off the Gantry power. Remove the tube covers (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523) to access Collimator and Tube Head. Page no. 1787 JC-PM-A-255.fm Chapter 11 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A255 - Collimator and Tube Head Cleaning 6 PROCEDURE 6-1 Clean Tube Head 1. Use the small static duster to clean both sides of the Tube Head as shown below. 2. Use the small static duster to clean the top of the Tube Head as shown below. Chapter 11 Page no. 1788 JC-PM-A-255.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PM A255 - Collimator and Tube Head Cleaning 6-2 Clean Collimator Note: It is not necessary to remove the Collimator when cleaning the Collimator. 1. Remove the two screws (5, one each side) securing the rear plate (6) which supports the FOV button (4 mm allen wrench). 4 3 2 5 6 2. Using an antistatic bag as protection, place the plate and FOV button on the X-ray head support arm. ! Notice: Do not attempt to disconnect the FOV button. Do not allow the plate to hang down; the FOV connection is fragile. 3. Remove the four screws (3, two each side) which secure the X-ray containment box (2). 4. Remove the X-ray containment box. If necessary, first remove the two screws (4) which secure the fan protection box. 5. Remove the four screws (7) securing the right collimator cover (small Pozi screwdriver). 7 6. Clean the right collimator cover with the small static duster, and ensure that it is free from dust. Page no. 1789 JC-PM-A-255.fm Chapter 11 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PM A255 - Collimator and Tube Head Cleaning 7. Remove the four screws (8) securing the left collimator cover (small Pozi screwdriver). 8 8. Clean the left collimator cover with the small static duster, and ensure that it is free from dust. 9. Inspect the mirror, and if it contains dust use a cotton bud or similar (e.g. a digital camera sensor cleaner) to clean it. If necessary, add some ethanol to the cotton bud to assist the removal of the dust. The use of ethanol may require that you clean the mirror a number of times, so that there is no smearing. ! Notice: The mirror surface is fragile. Ensure that you take care when cleaning the mirror, applying minimal pressure. Only use a cotton bud or similar (e.g. a digital camera sensor cleaner) to clean the mirror. Never touch the mirror with your fingers as the natural oils in your finger can damage the mirror. 10. Once the mirror is clean, use the cotton bud (or a cloth) to remove residual dust in the internal areas Chapter 11 Page no. 1790 JC-PM-A-255.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PM A255 - Collimator and Tube Head Cleaning of the collimator, as indicated below. Mirror side edge Flat surface behind lamp Flat surface below mirror 11. Reinstall the cleaned right collimator cover with the small screws (9) (small Pozi screwdriver). 9 Page no. 1791 JC-PM-A-255.fm Chapter 11 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PM A255 - Collimator and Tube Head Cleaning 12. Reinstall the cleaned left collimator cover with the small screws (10) (small Pozi screwdriver). 9 13. Reinstall the X-ray containment box. If necessary, first put back the two screws (11) to secure the fan protection box. 11 13 12 15 14 14. Reinstall the X-ray containment box (12) with the four screws (13, two each side). 15. Reinstall the plate and FOV button (14) on the X-ray head support arm with the two screws (15, one each side) (4 mm allen wrench). 16. Check visually that all screws securing the Collimator are well mounted. 7 COMPLETION 1. Power up the Senographe system. 2. Perform a Flat Field test using a Flat Field Phantom. 3. Determine your next step: • If the Flat Field test passes, switch off the Gantry power and replace the tube covers (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). • If the Flat Field test fails and there are artifacts in the ROI, switch off the Gantry power and return to section 6-2, Clean Collimator on page 1789. Note: If the Collimator and or Interface Plate moved while cleaning the Collimator, then perform a complete set of calibrations according to Completion on page 1373 in Job Card D/R A280 - Collimator Set. Chapter 11 Page no. 1792 JC-PM-A-255.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A300 - 21-inch 3MP Monitor Luminance Checks Job Card PM A300 - 21-inch 3MP Monitor Luminance Checks 1 Chapter 11 SUPPLIES None 2 • • TOOLS 3MP Test Pattern CD-ROM (P/N 5175614) A calibrated Luminance Meter that permits measuring the luminance of the monitor in contact (Direct) mode as illustrated below. ATTENTION: 1. When putting the Luminance Meter into contact with the monitor screen, do not apply excessive pressure. Remove canon and place foam ring 2. When measuring the luminance value of different parts of the screen, ensure that you apply the same level of pressure on each different part of the screen. Luminance Meter • If the Siemens Serial Spot Meter (P/N 2319223) is used, it must be used with the foam ring attached, and must be configured in Direct mode. Foam Ring Direct mode selected Away/Direct mode button selector • 3 The Away/Direct button toggles between away and direct modes. To select the Direct mode, keep pressing the Away/Direct button until D is displayed on the lower left corner of the Spot Meter screen. REQUIRED EFFORT Personnel: 1 Field Engineer Time: 60 minutes (including 30 minutes to let the monitor warm up) Page no. 1793 JC-PM-A-300.fm Chapter 11 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PM A300 - 21-inch 3MP Monitor Luminance Checks 4 APPLICABILITY The Job Card must be applied during the planned maintenance visit on systems containing the optional 21-inch 3MP Monitor (P/N 5350390). 5 SAFETY PRECAUTIONS None 6 PREREQUISITES The 21-inch 3MP Monitor has already been installed and configured to use 1 - DICOM mode and the maximum luminance is 400 cd/m² according to Monitor Mode Configuration on page 553 within Job Card ELE A008 - Configuring the 21-inch 3MP Monitor. 7 PROCEDURE 7-1 Install Test Images 1. Insert the Test Pattern CD-ROM into the DVD-ROM drive of the ADS Computer. 2. In the Browser, click the CDR read/write icon and select Query from the menu that appears. A Media Browser:CDR window appears. e b a c d 3. From the Media Browser:CDR window: a. Select the AAPM Test Patterns patient. b. Select the 1K-LUMIN Study ID. c. Select both the 2 and 4 Series (use the Control key to select both Series). d. Click the Disk icon under the Series list. From the Restore dialog box that appears, click OK. e. The test patterns from the Test Pattern CD-ROM are transferred to the patient list on the ADS Computer. During this transfer time, an animated data transfer icon towards of the top left of the Media Browser:CDR window appears. When the transfer of the test patterns is complete, the data transfer icon disappears. Chapter 11 Page no. 1794 JC-PM-A-300.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A300 - 21-inch 3MP Monitor Luminance Checks 4. Once the transfer of the test patterns is complete, click the top right corner of the Media Browser:CDR window to return to the main Browser window. The Patient List in the Browser now includes a Patient called AAPM Test Patterns, which contains the test patterns required to check the luminosity of the 21-inch 3MP Monitor. AAPM Test Patterns 5. In the Browser, click the CDR-read/write icon and select Detach from the menu that appears. The DVD-ROM drive of the ADS Computer opens. 6. Remove the Test Pattern CD-ROM and close the DVD-ROM drive. Page no. 1795 JC-PM-A-300.fm Chapter 11 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A300 - 21-inch 3MP Monitor Luminance Checks 7-2 Perform Luminance Tests 1. Ensure that the 21-inch 3MP Monitor has been powered on for at least 30 minutes. The 30 minute warm up period is necessary before performing the luminance tests. 2. From the Patient List in the Browser, select the AAPM Test Patterns Patient. AAPM Test Patterns 3. In the Study list, select the 1K-LUMIN Study ID. 4. In the Series list, select Series 2 (Procedure Description TG18-LN). 5. Click the Review Exam icon. The Exam Review window appears with images from the series. 6. If not already selected, use the Img up/down buttons to select the first image (number 1) in the series. Ensure that the title of the displayed image is TG18-LN12-01 Pattern. Lumiance Meter Position Chapter 11 Page no. 1796 JC-PM-A-300.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A300 - 21-inch 3MP Monitor Luminance Checks 7. With the TG18-LN12-01 Pattern displayed, use the luminance meter to measure the value of the black luminance at the center of the black box. Insert the measured black luminance value into row A of Table 1 on page 1800. The measured black luminance value must be less than 1 cd/m² for the monitor to pass the black luminance test. 8. Use the Img up/down buttons to select the 18th image (number 18) in the series. Ensure that the title of the displayed image is TG18-LN12-18 Pattern. Lumiance Meter Position 9. With the TG18-LN12-18 Pattern displayed, use the luminance meter to measure the value of the white luminance at the center of the white box. Insert the measured white luminance value into row B of Table 1 on page 1800. The measured white luminance value must be more than 350 cd/m² for the monitor to pass the white luminance test. 10. Calculate the contrast ratio. To do this, divide the white luminance value measured in step 9 by the black luminance value measured in step 7. Insert the calculated ratio into row C of Table 1 on page 1800. The calculated contrast ratio (white luminance divided by black luminance) must be greater than 100 for the monitor to pass the contrast ratio test. 11. Within the Exam Review window, use the Ser. up/down buttons to select Series 4 (Procedure Description TG18-UNL). 12. If not already selected, use the Img up/down buttons to select the first image (number 1) in the Page no. 1797 JC-PM-A-300.fm Chapter 11 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PM A300 - 21-inch 3MP Monitor Luminance Checks series. Ensure that the title of the displayed image is TG18-UNL10 Pattern. D2 D1 D5 D3 D4 13. With the TG18-UNL10 Pattern displayed, use the luminance meter to measure the luminance value at the center of five quadrants D1 to D5 illustrated above. Insert the measured luminance values for each quadrant into the following rows of Table 1 on page 1800 : • D1: top left quadrant • D2: top right quadrant • D3: bottom left quadrant • D4: bottom right quadrant • D5: center quadrant 14. Calculate the black non-uniformity value as follows: a. From the measured luminosity values of each corner quadrant (D1, D2, D3, and D4), determine the highest luminosity value (BLmax). b. From the measured luminosity values of each corner quadrant (D1, D2, D3, and D4), determine the lowest luminosity value (BLmin). c. The measured luminosity value of the center quadrant is BLcenter. Calculate the black non-uniformity value as follows: (BLmax - BLmin) / BLcenter. The black non-uniformity value must be less than 0.3 for the monitor to pass the black non-uniformity test. 15. Use the Img up/down buttons to select the second image in the series. Ensure that the title of the Chapter 11 Page no. 1798 JC-PM-A-300.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PM A300 - 21-inch 3MP Monitor Luminance Checks displayed image is TG18-UNL80 Pattern. E2 E1 E5 E3 E4 16. With the TG18-UNL80 Pattern displayed, use the luminance meter to measure the luminance value at the center of five quadrants E1 to E5 illustrated above. Insert the measured luminance values for each quadrant into the following rows of Table 1 on page 1800 : • E1: top left quadrant • E2: top right quadrant • E3: bottom left quadrant • E4: bottom right quadrant • E5: center quadrant 17. Calculate the white non-uniformity value as follows: a. From the measured luminosity values of each corner quadrant (E1, E2, E3, and E4), determine the highest luminosity value (WLmax). b. From the measured luminosity values of each corner quadrant (E1, E2, E3, and E4), determine the lowest luminosity value (WLmin). c. The measured luminosity value of the center quadrant is WLcenter. Calculate the white non-uniformity value as follows: (WLmax - WLmin) / WLcenter. The white nonuniformity value must be less than 0.3 for the monitor to pass the white non-uniformity test. 18. Click the Folder icon to close the Exam Review window. Page no. 1799 JC-PM-A-300.fm Chapter 11 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PM A300 - 21-inch 3MP Monitor Luminance Checks TABLE 1 - LUMINANCE TEST RESULTS Test Test Pattern Measured or calculated value Expected Result A Black luminance TG18-LN12-01 Pattern Pass: less than 1 cd/m² B White luminance TG18-LN12-018 Pattern Pass: greater than 350 cd/m² Pass/Fail Fail: greater than 1 cd/m² Fail: less than 350 cd/m² C Contrast ratio N/A Ratio of measured values between white luminance value and black luminance value Pass: greater than 100 Fail: less than 100 Pass: (BLmax - BLmin) / BLcenter is less than 0.3 D1 D2 D3 Black non-uniformity TG18-UNL10 Pattern Fail: (BLmax - BLmin) / BLcenter is greater than 0.3 D4 D5 Pass: (WLmax - WLmin) / WLcenter is less than 0.3 E1 E2 E3 White non-uniformity TG18-UNL80 Pattern Fail: (WLmax - WLmin) / WLcenter is greater than 0.3 E4 E5 8 COMPLETION If any of the luminance tests failed, change the 21-inch 3MP Monitor according to Job Card D/R A318 LCD Monitor on page 1469. If all of the luminance tests passed, no other action is required. Chapter 11 Page no. 1800 JC-PM-A-300.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A407 - Check HV Unit Job Card PM A407 - Check HV Unit 1 • • Chapter 11 SUPPLIES HV Grease HV Oil 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 5 minutes 4 SAFETY PRECAUTIONS WARNING Before beginning work, shut down the equipment and switch OFF the Senographe hospital supply circuit breaker. Lock it in the OFF position or mark it clearly with a warning sign to prevent others from applying power. NEVER switch off at the UPS except in emergency (risk of data loss). 5 PREREQUISITES Remove rear and left side covers from Generator and Conditioner Cabinet. Refer to Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513. 6 PROCEDURE To check the HV Unit, proceed as follows: 1. Remove HV connector and visually inspect earth braid continuity. 2. Check presence of oil or grease in HV connector. If necessary, add the appropriate product. 3. Reconnect HV connector and secure the locking screw. 4. Check for presence of oil leakage around the connectors on the top of the HV unit. If there is oil leakage, replace the HV unit as per D/R Job Card HV and kV/mA Tank. 5. Check that vent screw is open. 6. Perform a visual check of connectors on HV unit. Primary Winding HV Measurement Vent Screw XJ2 XJ1 XJ3 HV Connector 700-PL1 Page no. 1801 JC-PM-A-407.fm Chapter 11 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A407 - Check HV Unit This page is blank. Chapter 11 Page no. 1802 JC-PM-A-407.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A425 - IDC Air Filter Cleaning Job Card PM A425 - IDC Air Filter Cleaning 1 Chapter 11 SUPPLIES None 2 • • TOOLS Vacuum Cleaner Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 10 minutes 4 SAFETY PRECAUTIONS WARNING Before beginning work, shut down the equipment and switch OFF the Senographe hospital supply circuit breaker. Lock it in the OFF position or mark it clearly with a warning sign to prevent others from applying power. 5 • PREREQUISITES Shut down and switch off the equipment as per the Warning above. Page no. 1803 JC-PM-A-425.fm Chapter 11 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card PM A425 - IDC Air Filter Cleaning 6 PROCEDURE To clean the IDC air filter, proceed as follows: 1. Remove the screws (1) securing the air filter cover (2). 2 1 2. Remove the air filter, and use a vacuum cleaner to ensure that the air filter is free from dust. 3. Put back the air filter into the air filter cover (2). 4. Use the two screws to secure the both the air filter cover and air filter to the IDC framework. Chapter 11 Page no. 1804 JC-PM-A-425.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A428 - Conditioner Coolant Level Check and Top-up Job Card PM A428 - Conditioner Coolant Level Check and Top-upChapter 11 1 • 2 • • 3 SUPPLIES Coolant kit TOOLS Standard Tool Box Purge Tool REQUIRED EFFORT Personnel: 1 Field Engineer Time: 5 minutes 4 • • SAFETY PRECAUTIONS When filling or topping up the Conditioner, take great care to keep coolant away from the vents, the ON/OFF switch and the power cord connection. Do not immerse the Conditioner in any liquid. Dispose of old and surplus coolant with care as described in the section Surplus Coolant Disposal; refer to the Caution below. CAUTION • Before adding coolant to the Conditioner, always switch OFF the Generator and MDR circuit breakers in the Generator Cabinet. Switch on the MDR breaker only as instructed. • Always use a funnel when adding coolant to the Conditioner. • Always wear protective gloves and goggles when working with coolant. • When working with coolant you should treat it with care; avoid unnecessary contact . See below for First Aid advice: First Aid in case of contact with Conditioner coolant: Immediately flush eyes or skin with plenty of water for at least 15 minutes. If coolant contacts the eye, call a physician immediately. If coolant is swallowed, drink one to two glasses of water or milk. Avoid alcohol. Call a physician immediately. Remove and wash contaminated clothing before reuse. 5 PREREQUISITES Remove the Generator Cabinet covers as required for access to the Conditioner. Refer to Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513. 6 PROCEDURE CAUTION When performing any of the following procedures, be careful to avoid spillage of coolant, especially onto or near electrical connections. If any coolant is spilled, it must be cleaned up immediately. Page no. 1805 JC-PM-A-428.fm Chapter 11 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A428 - Conditioner Coolant Level Check and Top-up Note: A document describing an alternate procedure is provided in the coolant kit. For maximum safety and minimum risk of spillage, we recommend using the procedure given below: In terms of a planned maintenance, the coolant must be topped up every 12 months. This procedure and the procedure to change the coolant alternate per site visit, and are both undertaken on a 12 month basis. 1. Check the coolant level weekly or when the CHECK FLUID message appears. 2. When adding coolant use the container labelled Topping. 3. Remove the reservoir cap and check the liquid level. 4. If necessary, add liquid until it reaches the bottom of the cap threads. 5. Replace the reservoir cap when you are satisfied that the level is correct. 6. Clean the exterior of the Conditioner with a soft cloth and warm, soapy water. Never use abrasive or solvent-based cleaners to clean the Conditioner. 6-1 • • Surplus Coolant Disposal In a normal non-sensitive environment, used and surplus coolant may be disposed of by pouring down a drain. Triple-rinse containers before placing them in appropriate waste receptacles. Chapter 11 Page no. 1806 JC-PM-A-428.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A429 - Conditioner Air Filter Cleaning Job Card PM A429 - Conditioner Air Filter Cleaning 1 Chapter 11 SUPPLIES Roll of adhesive tape 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 5 minutes 4 SAFETY PRECAUTIONS WARNING Before beginning work, shut down the equipment and switch OFF the Senographe hospital supply circuit breaker. Lock it in the OFF position or mark it clearly with a warning sign to prevent others from applying power. 5 • • 6 PREREQUISITES Shut down and switch off the equipment as per the Warning above. Remove the Generator Cabinet covers as required for access to the Conditioner. Refer to Job Card PHY A042 - Remove/Reinstall Generator Covers on page 513. PROCEDURE To clean the Conditioner air filter, proceed as follows: 1. Loosen, without removing, screw (1) securing air duct (2) in place, then carefully remove air duct. Page no. 1807 JC-PM-A-429.fm 2 1 Chapter 11 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card PM A429 - Conditioner Air Filter Cleaning 2. Remove the air filter from its housing. Pull the plastic tab (3) towards the rear of the unit then pull the tab out to begin dislodging the air filter (4). 3. 4. Wash the air filter by holding the clean side of the air filter under running water for either two minutes or until the dirty side of the filter is clean. 5. Allow the filter to dry. 6. Use a piece of adhesive tape to remove any lint in the filter. 7. Replace the air filter in its housing. 8. Reassemble the air duct and secure it by tightening the screw. 9. Reassemble the Generator Cabinet covers. Chapter 11 4 3 Page no. 1808 JC-PM-A-429.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN End of the Publication End of the Publication You have reached the end of this Publication. To consult the Revision History, see Revision History on page 39. Page no. 1809 Last-Page.fm Manufacturer address: GE Medical Systems SCS 283, rue de la Minière - BP 34 78533 Buc Cedex France www.gehealthcare.com Imagination at work
Senographe DS and Essential Updating Gantry SW & FW CD-ROM Part Number: 5174994-11 Revision 3 Including "SW & FW Update
GE Healthcare Senographe DS Service Information and Procedures Class A SIP-A 0459 The page behind contains quick acces
Running as sdc... Run SetMonitorConfig.sh script with input SET 3MP Enter root password: Password: Sun Microsystems Inc. SunOS 5.10 Generic January 2005 Run SetScreenConfig script with input 3MP Remove existing setscreenenv file. Creating symbolic link /export/home/sdc/senovision/scripts/setscreenenv -> /export/home/ sdc/senovision/scripts/setscreen env3MP Enter root password : Password: 6. At the Password: prompt during the execution of the SetMonitorConfig.sh script, enter the root password (operator). The SetMonitorConfig.sh script continues to run, and when complete displays the following messages: Sun Microsystems Inc. SunOS 5.10 Generic January 2005 Current lang ext set Current lang ext set Current lang ext set Sun Microsystems Inc. SunOS 5.10 Generic January 2005 END of Script SetScreenConf - PLEASE REBOOT End of Script SetMonitorConfig - PLEASE REBOOT 7. Close the command line window, by entering: exit 8. Shutdown the system from the Browser shutdown button. 9. Wait two minutes for the UPS to be ready, then power up the system from the X-ray Console. Chapter 7 Page no. 552 JC-ELE-A-008.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A008 - Configuring the 21-inch 3MP Monitor 7-2 Monitor Mode Configuration The 21-inch 3 MP Monitor needs configuring to different settings to the factory defaults, so that: • Landscape mode is enabled (see section 7-2-2) • only the 1-DICOM mode is available and no other modes can be selected (see section 7-2-3 and section 7-2-4) • the mode window only appears for 15 seconds (see section 7-2-5) • the luminosity of the monitor is checked to be 400 cd/m² (see section 7-2-6) • the control buttons are inactive (to prevent the Operator changing the settings) (see section 7-2-7) Note: If the 21-inch 3 MP Monitor control buttons are locked, you can unlock them according to the procedure described in section 7-2-7. 7-2-1 General Controls This section descibes the general use of the 21-inch 3 MP Monitor control buttons and power LED. The right hand side of the 21-inch 3 MP Monitor contains various buttons and a LED as shown below. Control Panel 1 2 Existing Mode Setting Item Function Description 1 Power Indicator LED Indicates the monitor’s operational status: Green - ON, Yellow - Power Saving, not illuminated - OFF. 2 Power button Turns the monitor power on or off. 3 Navigational menu buttons Up, Left, Right, and Down buttons for selecting different monitor configuration menu items and adjustings 4 Enter button A single tap displays the ScreenManager menu, or confirms the selection of a menu item. A double tap saves adjusted values and closes configuration menu. 5 Mode button Toggles between different preset display modes 3 4 5 Note: The items in bold above are the names of the buttons used in the procedures below within this Job Card. Page no. 553 JC-ELE-A-008.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A008 - Configuring the 21-inch 3MP Monitor 7-2-2 Set the Monitor to Landscape Mode By default, the 21-inch 3 MP Monitor is set to Potrait mode. Use the following steps to configure the 21inch 3 MP Monitor to use Landscape mode. 1. Ensure that the 21-inch 3 MP Monitor is powered OFF. 2. While pressing the Mode button, press the Power button to power on the 21-inch 3 MP Monitor. The monitor powers up, and the Signal Selection window appears. 3. From the Signal Selection window select the Single Link/10bit item and press the Enter button. 4. From the Orientation window that appears, select the Landscape option and press the Enter button. 5. Double tap the Enter button to save the settings and close the Orientation window. Chapter 7 Page no. 554 JC-ELE-A-008.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A008 - Configuring the 21-inch 3MP Monitor 7-2-3 Enable the DICOM-1 Mode and Disable All Other Modes So the Operator cannot select other display modes, only the 1-DICOM mode must be enabled. 1. Press the Enter button to display the Screen Manager window. 2. On the Screen Manager window that appears, leave the item selected and press the Enter button. 3. On the Setup window that appears, leave the item selected and press the Enter button. 4. On the Setup - Mode Preset window that appears, use the Up/Down navigation menu buttons to select each mode, and the Left/Right navigation buttons to change the state to On/Off, as follows: - 1 - DICOM On - 2 - Custom Off - 3 - CAL Off - 4 - Text Off 5. When the settings for each mode are as described and shown above, double tap the Enter button to store the settings and close the Setup - Mode Preset window. Page no. 555 JC-ELE-A-008.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A008 - Configuring the 21-inch 3MP Monitor 7-2-4 Ensure the 1-DICOM Mode is Configured Even if you have disabled the other modes (i.e. Custom, CAL, and Text) one of them may still be enabled if it was selected before being disabled. Press the MODE button until the 1 - DICOM mode appears. Once the 1 - DICOM mode is chosen and the mode window closes, only the 1 - DICOM mode will be available). 7-2-5 Change the Mode Window Duration Time 1. Press the Enter button to display the Screen Manager window. 2. On the Screen Manager window that appears, keep pressing the Right navigation button until the item selected, and press the Enter button. 3. On the Others window that appears, keep pressing the Right navigation button until the item selected, and press the Enter button. 4. On the Menu Settings window that appears, keep pressing the Right navigation button until the item selected, and press the Enter button. 5. On the Menu Settings window that appears for the timer, keep pressing the Left navigation button to Chapter 7 Page no. 556 JC-ELE-A-008.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A008 - Configuring the 21-inch 3MP Monitor change the time to 15 sec. 6. When the settings for each mode are as described and shown above, double tap the Enter button to store the settings and close the Setup - Mode Preset window. 7-2-6 Ensure DICOM Mode is Operating at a Luminance of 400 cd/m² 1. Ensure that the 21-inch 3MP Monitor has been powered on for at least 30 minutes. The 30 minute warm up period is necessary before performing the luminance tests. 2. Insert the Test Pattern CD-ROM into the DVD-ROM drive of the ADS Computer. 3. In the Browser, click the CDR read/write icon and select Query from the menu that appears. A Media Browser:CDR window appears. e b a c d 4. From the Media Browser:CDR window: a. Select the AAPM Test Patterns patient. b. Select the 1K-LUMIN Study ID. c. Select the 2 Series . d. Click the Disk icon under the Series list. From the Restore dialog box that appears, click OK. e. The test patterns from the Test Pattern CD-ROM are transferred to the patient list on the ADS Computer. During this transfer time, an animated data transfer icon towards of the top left of the Media Browser:CDR window appears. When the transfer of the test patterns is complete, the data transfer icon disappears. Page no. 557 JC-ELE-A-008.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A008 - Configuring the 21-inch 3MP Monitor 5. Once the transfer of the test patterns is complete, click the top right corner of the Media Browser:CDR window to return to the main Browser window. The Patient List in the Browser now includes a Patient called AAPM Test Patterns, which contains the test patterns required to check the luminosity of the 21-inch 3MP Monitor. AAPM Test Patterns 6. In the Browser, click the CDR-read/write icon and select Detach from the menu that appears. The DVD-ROM drive of the ADS Computer opens. 7. Remove the Test Pattern CD-ROM and close the DVD-ROM drive. 8. From the Patient List in the Browser, select the AAPM Test Patterns Patient. AAPM Test Patterns 9. In the Study list, select the 1K-LUMIN Study ID. 10. In the Series list, select Series 2 (Procedure Description TG18-LN). Chapter 7 Page no. 558 JC-ELE-A-008.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A008 - Configuring the 21-inch 3MP Monitor 11. Click the Review Exam icon. The Exam Review window appears with images from the series. 12. Use the Img up/down buttons to select the 18th image (number 18) in the series. Ensure that the title of the displayed image is TG18-LN12-18 Pattern. Lumiance Meter Position 13. Press the Mode button on the Monitor Control Panel until the 1-DICOM mode is displayed. If necessary, press the Left/Right buttons on the Monitor Control Panel until the brigness value is 100%. 14. With the TG18-LN12-18 Pattern displayed, use the luminance meter to measure the value of the luminance at the center of the white box. Allow the displayed luminance value on the luminance meter to stablize. If the value of the luminance meter is 400 cd/m², no further action is required. If the value of the luminance meter is less than or greater than 400 cd/m², proceed as follows to ensure that the maximum luminance of the central white box is at 400 cd/m²: a. Press again the Mode button on the Monitor Control Panel to display the 1-DICOM mode. b. With the lumninance meter positioned at the center of the white box, press the appropriate UP or Down button on the Monitor Control Panel to adjust the brightness until the luminance meter measures 400 cd/m². Note: When adjusting the monitor brightness, adjust the monitor brightness in small increments and allow the displayed luminance value on the luminance meter to stablize. 15. Click the Folder icon to close the Exam Review window. Page no. 559 JC-ELE-A-008.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A008 - Configuring the 21-inch 3MP Monitor 7-2-7 Locking and Unlocking the Control Buttons Before handing the system over to the Operator, you must ensure that the control buttons on the 21-inch 3 MP Monitor locked. The procedure to lock and unlock the control buttons (i.e. toggle between the two states) is the same, and is as follows: 1. Ensure that the 21-inch 3 MP Monitor is powered OFF. 2. While pressing the Enter button, press the Power button to power on the 21-inch 3 MP Monitor. The lock state of the control buttons on the 21-inch 3 MP Monitor will change from its existing state (i.e. unlocked or locked) to the other state (i.e. locked or unlocked). 3. Press the Enter button to see if the Screen Manager window appears. • If the Screen Manager window appears, the control buttons are not locked. If you are handing the system back to the Operator, press the Power button to power off the 21-inch 3 MP Monitor, then return to step 1. • Screen Manager window does not appear, the control buttons are locked. If you are handing the system back to the Operator, no further steps are required. Chapter 7 Page no. 560 JC-ELE-A-008.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A009 - Generator Configuration Job Card ELE A009 - Generator Configuration 1 Chapter 7 INTRODUCTION This module provides information for initial configuration of a Senographe system. It contains two sections: • Configuration procedures. Procedures which are required to set up the system for local site conditions. • Configuration check information. For use only if you suspect that certain important settings have been changed; most settings are made in the factory and do not need to be changed on site. 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 40 minutes 4 CONFIGURATION PROCEDURES 4-1 Prerequisites The system must have powered up and reached a stable state with no checksum error displayed on the X-ray Console. • If, on the first power up, CHECKSUM ERROR (GEN) appears, proceed as follows: Reload the Generator saved parameters, using the delivered diskette (PN 2152250) or CD-R that are to be used to save the generator parameters. This diskette is labeled with the same product locator number as your Senographe system. The CD-R is labeled as the Generator Backup. The files are identified as Gxxxx.DAT (Generator), where xxxx is the factory serial number. There should be no checksum error after a correct reloading of these parameters. • Perform a checksum (SETUP/GENE/INSTAL/CKSUM/CKSUM) and return to the Application mode. 4-2 • Set Language If necessary, change the X-ray Console display language by selecting: SETUP/LANGUAGE/Select LANGUAGE, where LANGUAGE is the desired language (FRANC, ENGL, DEUTS, ESPAN, ITALI, PORTU, DANIS, FINNI, DUTCH, NORWI, or SWEDI ). Note: For compatibility with the English language documentation, you are recommended to select ENGL during installation of the system; change to the local language when the installation is complete. Page no. 561 JC-ELE-A-009.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A009 - Generator Configuration 4-3 Set Gantry Medical Parameters 1. Ask the doctor for the desired paddle compression speed (fast or slow). From application mode, select SETUP/MEDICAL/COMP/SPEED. Select FAST or SLOW as required. 2. Ask the doctor for the desired maximum compression force in daN. Select SETUP/MEDICAL/COMP/ FORCE. Press + or - on the X-ray Console repeatedly until the desired force value is reached. Possible values range from 4 daN to 20 daN in steps of 1 daN. Select VAL on the X-ray Console to confirm the desired value. Note: The ACR recommendation is 18 daN (40 lbs). 3. Ask the doctor if they desire automatic decompression following an exposure (i.e. return of the compression paddle to its home position). Select SETUP/MEDICAL/DECOMP/DECOMP. Select YES or NO as required. 4. Select SETUP/MEDICAL/BEEP, and ensure that YES is selected. 5. Ask the doctor for the desired maximum height during automatic decompression (between 10 cm and 38 cm). Select SETUP/MEDICAL/DECOMP/HEIGHT. Press + or - on the X-ray Console repeatedly until the desired maximum height appears. • Perform a checksum (SETUP/GENE/INSTAL/CKSUM/CKSUM) and return to the Application mode. 4-4 • Select SETUP/GENE/INSTAL/GENE/CONFIG/CONFIG/PMAX/3.0, to set the maximum generator power to 3.0 kW. 4-5 • Set Maximum Generator Output Power Set Maximum X-ray Tube mAs Select SETUP/GENE/INSTAL/GENE/CONFIG/CONFIG/MASMAX. Enter the maximum mAs value according to local regulations, using the NEXT and VALID keys and rotating the kV dial. Note: The default (and maximum possible) value is +6.000E+2 (600) mAs. • Perform a checksum (SETUP/GENE/INSTAL/CKSUM/CKSUM) and return to the Application mode. 4-6 • Set Maximum X-ray Exposure Time Select SETUP/GENE/INSTAL/GENE/CONFIG/CONFIG/T_MAX. Enter the maximum X-ray exposure time according to local regulations. Note: The default and maximum admissible value is +6.000E+0 (6) seconds. • Perform a checksum (SETUP/GENE/INSTAL/CKSUM/CKSUM) and return to the Application mode. Chapter 7 Page no. 562 JC-ELE-A-009.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A009 - Generator Configuration 5 CONFIGURATION CHECK INFORMATION Note: It is not normally necessary to set the configuration parameters listed here. They are set to their correct values in the factory, or by the link from the AWS. They are given here for convenience in the event that you suspect that they have been changed, perhaps during troubleshooting. 5-1 • Set Date and Time The Generator clock updates automatically via the AWS each time the Senographe subsystem is powered up (either alone or when the complete system is powered up). It is not normally necessary to change it manually. Note: After a Generator CLEAR operation, the current date and the date of the last installation mode access are both set to the Generator software release date; the time is set to 0:00:00. The current date and time are updated at the next power up. • The clock is used for the following functions: - Thermal protection cooling algorithms, whether the Generator is turned on. - Recording dates and times in the error log. - Recording the date of last access to installation mode. • If it is necessary to change the date or time on the Gantry manually, note the following points: - Dates (menu path: SETUP/GENE/INSTAL/GENE/CONFIG/DAY) are entered in the form DD/MM/YY; e.g., for February 14th, 2003, you must enter 14/02/03. - Time (menu path: SETUP/GENE/INSTAL/GENE/CONFIG/HOUR) is entered in 24-hour format; e.g., for 3:13:27 pm you must enter 15:13:27. • Perform a checksum (SETUP/GENE/INSTAL/CKSUM/CKSUM) and return to the Application mode. 5-2 Check X-ray Tube Type 1. Select SETUP/GENE/INSTAL/GENE/CONFIG/CONFIG/TUBE. Check that the X-ray Console display shows the correct tube type: 2foc/2met/1ang (dual focus, bimetal, single anode angle, or slope; This corresponds to tube type Maxiray TH100-M1). 2. Select SETUP/GENE/INSTAL/GENE/CONFIG/CONFIG/TUBE/MODEL and choose MAXRAY TH100-M1. If the configuration on step 1 is not correct, proceed with steps 3 and 4 below. 3. If necessary, set the correct X-ray tube type: Select FOCUS/DUAL on the X-ray Console. Select SETUP/ANODE/DM on the X-ray Console. 4. Press SETUP; check that the X-ray Console display now shows the correct tube type (above). • Perform a checksum (SETUP/GENE/INSTAL/CKSUM/CKSUM) and return to the Application mode. Page no. 563 JC-ELE-A-009.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A009 - Generator Configuration 5-3 Check Presence Parameters The following equipment presence parameters must normally be set to YES: • Gantry (Arm) presence; SETUP/GENE/INSTAL/GENE/CONFIG/CONFIG/PRES/PRS-B • Digital System presence; SETUP/GENE/INSTAL/GENE/CONFIG/CONFIG/PRES/PRS-DS • IDC presence; SETUP/GENE/INSTAL/GENE/CONFIG/CONFIG/PRES/PRS-IDC • Perform a checksum (SETUP/GENE/INSTAL/CKSUM/CKSUM) and return to the Application mode. 5-4 • Check Paddle Deformation Parameters Check the values of paddle deformation parameters against the default factory settings are all set to 0.000 E+0. These parameters alter the X-ray exposure behavior in AOP mode. 18 x 24 paddle in contact mode: access SETUP/GENE/INSTAL/GENE/AOP/PELOTE/18x24 Magnification paddles: access SETUP/GENE/INSTAL/GENE/AOP/PELOTE/MAGN • Paddle Offset Value Gain Value Standard metallic arm paddle (*) 0 0 All magnification paddles(*) 0 0 Do not perform any modification of the Paddle deformation parameters. Chapter 7 Page no. 564 JC-ELE-A-009.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A010 - Set Lift Travel Limits Job Card ELE A010 - Set Lift Travel Limits 1 Chapter 7 SUPPLIES None 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 15 minutes 4 SAFETY PRECAUTION No specific safety precautions are applicable. 5 PREREQUISITES None 6 PROCEDURE 6-1 Principle The illustration below highlights the important principles behind setting the lift travel limits. Ceiling Key LE: Lift Encoder LP: Lift Potentiometer Upper lift travel limit Derived from the lift travel limit plus the lower lift travel limit 1 850 mm 750 mm Top 650 mm Middle Bottom Lower optical fork position (fixed) Floor 0 mm LE LP 670 ±2 mm Lift travel limit 4 Set in the ADS software and must correspond to upper optical fork position Lift Potentiometer Upper Reference Voltage Set with FOV size button 650 mm — this automatic stop distance during the calibration phase is determined by the Lift Encoder which accurately translates lift screw turns to height traveled. Lower lift travel limit Measured then set Page no. 565 JC-ELE-A-010.fm 3 Lift Board Firmware Upper optical fork position Lift Potentiometer Lower Reference Voltage 2 Set with FOV size button Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A010 - Set Lift Travel Limits The numbered circles 1, 2, 3 and 4 correspond to the procedural sections within this Job Card as follows: 1. 6-2-1, Upper Optical Fork Positioning 2. 6-2-2, Lower Limit Adjustment (Lift Potentiometer Lower Reference Voltage at 0 mm) 3. 6-2-3, Upper Limit Adjustment (Lift Potentiometer Upper Reference Voltage at 650 mm) 4. 6-2-4, Selection of the Lift Travel Limit (Completion) The top of the Senographe system Tube Head can travel up to three discrete maximum heights, corresponding to each of the three different lift travel limits. The maximum Tube Head heights and minimum required ceiling corresponding to each of the three different Lift Travel Limits, are as follows. Lift Travel Limit Corresponding Upper Optical Fork Position Corresponding Max. Tube Head Height * Recommended Min. Ceiling Height ** 650 mm Bottom 2230 mm 2300 mm 750 mm Middle 2330 mm 2400 mm 850 mm (default setting) Top (default setting) 2430 mm 2500 mm * - Assumes that the lower lift travel limit is accurately set. ** - The recommended minimum ceiling height assumes that there is a marginal gap of 70 mm between the top of the Tube Head and the ceiling. Note: The information in the table above assumes that you have accurately set the lower lift travel limit to 670 ±2 mm from the floor. Goal of Calibration: • Select the upper optical fork position to avoid collision with the ceiling. • Calibrate the Lift Potentiometer. • Set the lift lower limit and the lift travel limit in software, defining the minimum and maximum usable heights. Chapter 7 Page no. 566 JC-ELE-A-010.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A010 - Set Lift Travel Limits 6-2 Calibration Procedure 6-2-1 Upper Optical Fork Positioning • Use a measuring tape to measure the height of the ceiling: Ceiling Height: ____ mm 1. If the ceiling height is equal to or greater than 2500 mm (98.4 inches) (measured from the floor), - Leave the optical fork in the default position (the upper position, allowing 850 mm lift travel), 2. If the ceiling height is between 2400 mm (94.6 inches) and 2500 mm (98.4 inches) - Remove the front covers (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). - Place the optical fork in the middle position (allows 750 mm lift travel). 3. If the ceiling height is between 2300 mm (90.6 inches) and 2400 mm (94.6 inches) - Remove the front covers (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers on page 523). - Place the optical fork in the lower position (allows 650 mm lift travel). Fork position set by default at installation 850 mm lift travel 100 750 mm lift travel 100 650mm lift travel See Rotation /Lift - Rear View on page 192 to locate the upper optical fork. Note: The ceiling height ranges quoted above assume that there is a 70 mm marginal space between the top of the Tube Head and the ceiling. 6-2-2 Lower Limit Adjustment (Lift Potentiometer Lower Reference Voltage at 0 mm) Use the following steps to set the lower lift travel limit (which corresponds to the Lift Potentiometer Lower Reference Voltage): 1. Launch the Service Desktop (see Launching the Service Desktop on page 120) then click the Calibration button . 2. From the Calibration Home Page that appears, click the Positionner button. 3. From the Calibration: Positioner Summary page that appears, click the Lift button. 4. From the Lift Position and Upper Limit Calibration page that appears, follow the on-screen instructions: set the arm rotation position to 0° and remove the Bucky.Then press the Start button to start the calibration process. The Gantry LCD updates with the following message: Adjust lower limit. Lower arm until you reach min usable height defined in JC ELE A010. Then press Page no. 567 JC-ELE-A-010.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A010 - Set Lift Travel Limits the FOV button. 5. Measure the height of the flat surface of the detector (A) with respect to the top of the gantry base plate (B), as shown. A B 6. Use the control buttons on the Tube Head to move the lift down until the measured height at the detector is 670 ±2 mm (26.4 ±0.1 inches). Note: If you move the detector below 670 ±2 mm and too close to 660 mm, the lower optical fork is obstructed, invoking a system halt. If you invoke a halt you have to move manually the lift shaft to raise the detector and start again. 7. When the measured height at the detector is 670 ±2 mm (26.4 ±0.1 inches), press the FOV size button (behind the Tube Head). This action signals the completion of the lower limit adjustment. The voltage of the Lift Potentiometer is sent to the firmware of the Lift Board and stored as the Lift Potentiometer Lower Reference Voltage. The Gantry LCD updates with the following message: Lower position successfully calibrated. Move to upper position. When reached press FOV button. You must now proceed to Upper Limit Adjustment (Lift Potentiometer Upper Reference Voltage at 650 mm) on page 568 to set the upper Lift Potentiometer Upper Reference Voltage. 6-2-3 Upper Limit Adjustment (Lift Potentiometer Upper Reference Voltage at 650 mm) Use the following steps to calibrate the upper limit of the Lift Potentiometer: 1. When the Gantry LCD instructs you to move the lift to the upper position, use the control buttons on the Tube Head to move the lift up to its highest possible position until it automatically stops. The movement stops automatically when the lift reaches 650 mm above the lower limit. The 650 mm is determined by the Lift Encoder which accurately translates lift screw turns to height traveled. 2. Once the lift reaches its highest position and automatically stops, press the FOV size button (behind the Tube Head). This actions signals completion of the upper limit adjustment. The voltage of the Lift Potentiometer is sent to the firmware of the Lift Board and stored as the Lift Chapter 7 Page no. 568 JC-ELE-A-010.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A010 - Set Lift Travel Limits Potentiometer Upper Reference Voltage. The Gantry LCD updates with the message "Lift node fully calibrated. Calibration can be saved or canceled on ADS." and the AWS screen updates instructing you to either save or cancel the calibration (see Selection of the Lift Travel Limit (Completion) on page 569). ! Notice: If you do not move the lift up to its highest possible position until it automatically stops, and you press the FOV size button the Gantry LCD updates with the message "Upper lift position out of range. Check lift position or positioner signal! Then press FOV button.". In this case simply continue to move the lift up to its highest possible position until it automatically stops and then press the FOV size button. 6-2-4 Selection of the Lift Travel Limit (Completion) Use the following steps to save the calibration results and set the lift travel limit,: 1. On the Lift Position and Upper Limit Calibration page, click the Save button. A Lift Optical Fork Position Calibration page on the appears prompting you to select the upper optical fork position. 2. Click the button corresponding to the upper optical fork position that you set in Upper Optical Fork Positioning on page 567, as follows: - click the 850 mm button if the upper optical fork is in the upper position - click the 750 mm button if the upper optical fork is in the middle position - click the 650 mm button if the upper optical fork is in the lower position - click the No Change button if the upper optical fork has not been moved 3. From the Lift Calibration SAVED page that appears, click the OK button. You are returned to the Calibration: Positioner Summary page. 4. From the Calibration: Positioner Summary page, click the Exit button to leave the Service Desktop. 6-2-5 Check the Lift Lower and Upper Travel Limits Move the Arm to the lower position, then to the upper position and check whether the Arm stops at the right positions. Page no. 569 JC-ELE-A-010.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A010 - Set Lift Travel Limits This page is blank. Chapter 7 Page no. 570 JC-ELE-A-010.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A012 - X-ray Parameter Check Job Card ELE A012 - X-ray Parameter Check 1 Chapter 7 SUPPLIES None 2 • • TOOLS Set of acrylic plates Meter for measurement of mAs. The meter used must be in good condition and possess valid certification. Suitable meters are: - Fluke 87 multimeter - Keithley 35035 mAs meter - GS Poner 165 mA-mAs meter 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 40 minutes 4 SAFETY PRECAUTIONS The procedures in this Job Card produce X-rays. Ensure that you take appropriate precautions when operating with X-rays (for example, stay behind the radiation screen during an X-ray exposure). 5 PREREQUISITES None 6 GENERATOR TESTING You must check the Generator kV, mA, and mAs calibrations, which have already been made in the factory. 6-1 Set Up the Generator for Testing 1. Configure the Senographe for the following exposure: - Mode manual (2-point) - Focal spot: large - Track: Mo - Filter: Mo - mAs: 60 (lower mAs value can give inaccurate measurements) - HV: 22 kV 2. Activate display of parameters following an exposure by selecting SETUP/GENE/INSTAL/GENE/ CONFIG/DISP/YES on the X-ray Console. Return to application mode. 3. Connect the digital mAs meter to kV mA board 701-PL1 (on the HV tank unit 701) between terminals MES_MA_POS and MES_MA_NEG. Disconnect the jumper that is normally between these two terminals. 4. Set the mAs meter to current (mA) measurement. Page no. 571 JC-ELE-A-012.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A012 - X-ray Parameter Check 5. Protect the detector using 25 mm of acrylic. 6. Open New Patient in the Browser. Take five exposures at approximately 20 second intervals, incrementing the HV by 2 kV each time (i.e., 22 - 24 - 26 - 28 - 30 kV). 7. Take five more exposures at the same interval, leaving the HV set at 30 kV. 8. The X-ray tube current value displayed on the X-ray Console (Idisplay) must be 100 mA ± 5 mA, and must agree with the value read on the mAs meter (Imeasure) ± 5%. If Idisplay is not equal to Imeasure then perform the procedures of Job Card CAL A009 - X-Ray Tube mA Measurement on page 1663, followed by Job Card CAL A012 - X-Ray Tube Heater Current on page 1673. 9. Take two exposures at 40 kV and 50 mAs at an interval of 30 seconds. No arcing must be detected. If arcing is detected, perform the procedure given in Job Card CAL A007 - Automatic X-ray Tube Warm-Up on page 1661. 10. Reconfigure the Senographe to 30 kV and 25 mAs. Take one exposure for each of the three following focal spot/track combinations and check the expected X-ray tube current reading on the X-ray Console display: SMALL FOCAL SPOT/MO TRACK => I = 40 mA ±2 mA SMALL FOCAL SPOT/RH TRACK => I = 35 mA ±2 mA LARGE FOCAL SPOT/RH TRACK => I = 62 mA ±4 mA 11. Disconnect the mAs meter from the Senographe and reconnect the jumper on kV mA board 701PL1. 12. Verify kVp using a non-invasive kVp meter and, if needed, perform Job Card CAL A011 - Calibration of kV Scale Factor on page 1667. This step may be mandatory, when required by local regulations. Chapter 7 Page no. 572 JC-ELE-A-012.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A013 - AWS Configuration Job Card ELE A013 - AWS Configuration 1 Chapter 7 SUPPLIES None 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 40 minutes 4 SAFETY PRECAUTIONS None 5 PREREQUISITES None 6 PROCEDURE 6-1 Display the Configuration/System Overview Window 1. From the Browser, launch the Service Desktop (see Launching the Service Desktop on page 120). 2. From the Service Desktop, click the Configuration button . The System Overview appears showing the current site and communications settings. 6-2 Set Site Information 1. Click Site under Configuration to display the Site Information screen. Page no. 573 JC-ELE-A-013.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A013 - AWS Configuration 2. To change any of the displayed items, type the new information and confirm the entry by clicking the Submit button. Note: 1. This screen supports all US ASCII characters (i.e. roman alphabet letters, numbers, and classic symbols). All accented characters are not supported, and must be substituted by appropiate letters. 2. The entry Station Name is the name (hostname) that is used for the system when interacting with the RIS server. The Station Name must be the same value as the hostname that is defined in the TCP/IP networking configuration of Job Card ELE A021 - Networking Connection and Configuration on page 625. Do not use the following characters in the Station Name: ! $ ” ‘ ’ { } [ ] * @ # ? ^ _ / etc. ONLY USE ALPHANUMERIC CHARACTERS WITHOUT SPACES. It is also possible to use the characters - (dash) and . (dot). Ensure that the Station Name is no more than 12 characters long. 3. If there is more than one Senographe system on the hospital site, the names chosen must clearly differentiate between them. For example, by including the unit number or name). 6-3 Set General Configuration Parameters 1. Click General under Configuration to display the General Configuration screen. 2. To change any of the displayed items, type the new information and/or select a different option in the following: a. The System Clock yyyy mm dd and hh:mm:ss fields set the current date and time, respectively. ! Notice: After changing the clock the system must be shut down and restarted. If this is not done, system behavior can be unpredictable, because several interacting processes use the clock. Chapter 7 Page no. 574 JC-ELE-A-013.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A013 - AWS Configuration b. The QAP Time-out field sets the time (in days) at which a warning that QAP must be carried out, is displayed. c. The Screen Blank Timeout field sets the delay time (in minutes) that the screen will go blank if there has been no mouse or keyboard activity. This Screen Blank Timout value must not be confused with the Auto-Logoff Timout, which is described in Changing the Auto-Logoff Timeout on page 576. d. If the Auto Delete feature is activated (see Enabling The Auto Delete Feature on page 575), then the Auto Delete parameters are applied. When the disk usage exceeds the configured Upper Threshold value, images are automatically deleted. They are deleted in chronological order, oldest first, until the disk space reaches the Lower Threshold. Images which have been on the disk for less than the Minimum Image’s Storage Time are not deleted. If neccessary, change the default Auto Delete parameters according to the customer requirements. ! Notice: Do not activate Auto Delete or change Auto Delete settings without agreement from the customer. e. The Language check boxes allow you to set the required application language for the Browser, Worklist and Viewer. Changing the language impacts the only the Browser, Worklist and Viewer. The Service Desktop remains in English. f. The Edit Patient radio buttons allow you to determine whether the Edit Patient function is activated when the Edit Patient command is selected from the Tools menu. If On is selected, patient details can be edited. If Off is selected, patient details cannot be edited, and a dialog box appears suggesting that the Edit Patient function is discativated. ! Notice: If you change the application language, you must perform a shutdown and restart before the change takes effect. 3. When you are happy with the changes, confirm them by clicking the Submit button. 6-4 Enabling The Auto Delete Feature By default, the auto-delete feature is not active. If the customer wants to activate the auto-delete feature, perform the following steps: 1. Click the Tools menu button , then click Medical application preferences 2. From the medAppPrefs window that appears, click the Auto delete button. 3. Click the Auto delete ON radio button, and click the appropriate radio buttons to define your auto delete profile. 4. Click the Save button. Page no. 575 JC-ELE-A-013.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A013 - AWS Configuration 6-5 Changing the Auto-Logoff Timeout The Auto-Logoff Timeout sets the delay (in minutes) that the screen will return to the ADS Login Screen if there has been no mouse or keyboard activity. This delay does not apply if the system is in Acquistion mode. The default Auto-Logoff Timeout is never for V1/V2 Control Stations, and 15 minutes on V3/V4 Control Stations. If the default Auto-Logoff Timeout needs changing, use the following steps: 1. Click the Logout button in the Browser to return to the ADS Login Screen. 2. At ADS Login Screen, login as the admin user (the default factory password is admin). 3. Configure the Auto-Logoff Timeout delay as follows: For V1/V2 Control Stations, do the following: a. Click the Password Constraints tab. b. Type a new Auto-Logoff Timeout delay value (in minutes) in the Delay before re-authentication (minutes) field, and uncheck the Never check box. c. Clickthe Apply button. d. Click the Exit Admin button. Chapter 7 Page no. 576 JC-ELE-A-013.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A013 - AWS Configuration For V3/V4 Control Stations, do the following: a. Click the Configuration tab. b. Type a new Auto-Logoff Timeout delay value (in minutes) in the Inactivity Timeout (minutes) field. c. Clickthe Apply Configuration button. d. Click the Exit button. Page no. 577 JC-ELE-A-013.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A013 - AWS Configuration This page is blank. Chapter 7 Page no. 578 JC-ELE-A-013.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A015 - Gantry Functional Checks Job Card ELE A015 - Gantry Functional Checks 1 Chapter 7 SUPPLIES None 2 • • TOOLS Mammography compression scale with digital display Set of acrylic plates 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 10 minutes for breast thickness measurement, 17 minutes for others. 4 SAFETY PRECAUTIONS The procedures in this Job Card produce X-rays. Ensure that you take appropriate precautions when operating with X-rays (for example, stay behind the radiation screen during an X-ray exposure). 5 PREREQUISITES None 6 GANTRY TESTING You must check the basic functions of the Gantry. During each power-up sequence, the software tests the following functions: - Filter holder rotation - Lateral, front, and rear collimator blade movement - X-ray tube housing movement - Compression paddle movement to home position - Column movement limit stops - Coherency between focal spot size, magnification, and X-ray tube housing angulation - Grid movement - Generator-Gantry communications link - Gantry CPU board 6-1 Check Gantry Readout Immediately following the power-up sequence, the Gantry readout must indicate the X-ray format. 6-2 Check Column Movement 1. With the compression paddle out of compression, check that all four sets of column up/down control buttons are operational. Check each button for up and down movement of the column. 2. Move the column to its upper and lower limits. Software limits must stop movement. If software limits have failed, the optical forks are used to recognize and stop any movement before impact with mechanical stops.Total one-way movement time (going either up or down) between upper and lower limits must be 8 ±2 seconds. 3. Movement must be smooth and progressive; check for any noise which can indicate excessive friction or binding. Page no. 579 JC-ELE-A-015.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A015 - Gantry Functional Checks 6-3 Check Arm Rotation 1. With the compression paddle out of compression, check that all four Arm rotation control buttons are operational For each button, check that light or firm pressure gives the correct rotation, and that rotation stops when the pressure is released. Refer to section 6-4 Keypad Functional Checks for a full list of these checks. 2. Rotate the Arm through its full range of +185°/-165°. Check in several positions that the electrical braking is functioning correctly, by pulling on the handles. 3. Movement must be smooth and progressive; check for any noise which can indicate excessive friction or binding. 4. Check alignment of angle markings at 0°. 6-4 Keypad Functional Checks 1. Check the operation of each keypad button by performing the operations listed in the table below. The button references used are shown in the following illustration: Operation Button Tube Head Keypad Left Slow rotation to the left * 4 (light press) Fast rotation to the left * 4 (firm press) Slow rotation to the right * 4 (light press) Fast rotation to the right * 4 (firm press) Slow lift upwards 5 (light press) Fast lift upwards 5 (firm press) Slow lift downwards 5 (light press) Fast lift downwards 5 (firm press) Central preset position (CC) 2 (touch once) Left preset position (+ Oblique) 1 (touch once) Right preset position (- Oblique) 3 (touch once) Arm Keypad Right Left Right * Press the top or bottom of button 4 for rotation in the direction of the arrow, to right or left according to the position of the keypad. Left of Arm 3 4 5 5 4 1 Right of Arm 2 2 3 1 2. Check that movements stop automatically when the keypad button is released. Perform each of the rotation and lift movements again, but release the button before the limit position is reached and check that the movement stops. Chapter 7 Page no. 580 JC-ELE-A-015.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A015 - Gantry Functional Checks Perform this check at least three times for each button. Operation Button Tube Head Keypad Left 6-5 Slow rotation to the left 4 (light press) Fast rotation to the left 4 (firm press) Slow rotation to the right 4 (light press) Fast rotation to the right 4 (firm press) Slow lift upwards 5 (light press) Fast lift upwards 5 (firm press) Slow lift downwards 5 (light press) Fast lift downwards 5 (firm press) Right Arm Keypad Left Right Check Light Centering Device Press one of the light centering device activation buttons.; check that the device lights for 30 seconds. 6-6 Check Format Control Check that repeated presses on each of the two format control push buttons give the sequence: 1) light centering device lights; 2) first format reduction; 3) second format reduction; 4) full format. 6-7 Check Magnification Sensors 1. With the magnification device removed, the Gantry readout must show a magnification of 1.0. 2. Install the two magnification stands in turn. The Gantry readout must show magnifications of 1.5 and 1.8, according to the device installed. 6-8 Check Paddle Compression 1. Check that both sets of compression/decompression pedals and the manual compression knobs located on the paddle holder all function correctly. That is, the paddle moves up or down in response to each command. 2. Use the Mammography Compression Scale placed between the Bucky and the compression paddle to check calibration of the compression force display on the Gantry readout. Measure one point at 5 daN and one point at 15 daN. The value on the Gantry readout must agree within ±1 daN. If it does not, performJob Card CAL A048 - Calibration of Compression Force Sensor on page 1709. If the recommended compression measurement tool is not available, this verification can be done as follows: - Lowering the paddle close to the top surface of the Bucky - Install the magnification device. - Connect a spring dynamometer (calibrated from 0 kg to 15 kg) between the compression paddle and the magnification device. 6-9 Check Breast Thickness Measurement 1. Install the Bucky and place the corner of a 10 mm thick acrylic plate. The plate must be positioned at 45°, entering about 80 mm from the chest wall. 2. Lower the compression paddle into contact with the acrylic plate. 3. Slowly increase compression force on the acrylic plate while watching the breast thickness display on the Gantry readout. The displayed value must remain in the range 10 mm ±2 mm for any value of Page no. 581 JC-ELE-A-015.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A015 - Gantry Functional Checks compression force between 5 kg and 15 kg. 4. Repeat the check as described above, but using a 50 mm thick acrylic plate. The displayed value must now remain in the range 50 mm ±2 mm for any value of compression force between 5 kg and 15 kg. 5. If either or both of the above checks gives an unsatisfactory result, perform the procedures described in Job Card CAL A050 - Compression Thickness Calibration on page 1721. 6-10 Check Stop Motion Buttons Check the red stop motion buttons (located on either side of the Gantry column base). • Both of these buttons must be tested: - Press one of the stop motion buttons and check that all movement of the Gantry is stopped. - Restart the Gantry. Press the other stop motion button and check that all movement of the Gantry is stopped. Chapter 7 Page no. 582 JC-ELE-A-015.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A017 - Manual Compression Check and Calibration Job Card ELE A017 - Manual Compression Check and Calibration Chapter 7 1 SUPPLIES None 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 10 minutes 4 SAFETY PRECAUTIONS None 5 PREREQUISITES None 6 CHECK MANUAL COMPRESSION You must check that the maximum force which can be applied by manual compression is within limits. 1. Set the Compression Arm to the vertical position. 2. Place a phantom on the Bucky. 3. Turn the manual compression knob to apply compression to the phantom until the torque limiter prevents any further increase in compression. Note the value of compression displayed on the Gantry readout. ! Notice: When applying compression, use your fingers to turn the compression knob. Do not allow the mass of your hand and arm to rest on the knob, as this could affect the value of compression. 4. The compression reading must be between 27 daN and 30 daN. If the reading is in this range, no calibration is required and the check is complete. 5. If the reading is outside the specified range, the torque limiter must be calibrated. Continue with the appropriate procedure as described in section 7. Page no. 583 JC-ELE-A-017.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A017 - Manual Compression Check and Calibration 7 TORQUE LIMITER CALIBRATION • Refer to the following illustration when carrying out the procedures described below. Adjusting nut Decrease torque limit Increase torque limit Tapped hole for set screw 7-1 • If the measured value of maximum compression force is greater than the upper limit of 30 daN, proceed as follows: 1. Remove the set screw from the torque limiter (2 mm allen wrench). 2. Turn the adjusting nut counter-clockwise until the set screw hole coincides exactly with the next hole in the lock washer underneath the adjusting nut. 3. Screw the set screw into its position in the adjusting nut, taking care to ensure that it enters the hole in the lock washer. It must not exert pressure on the washer. 4. Repeat the check and adjustment procedures until the measured maximum compression force is within the specification. 7-2 • Adjustment - Measured Value Over the Limit Adjustment - Measured Value Under the Limit If the measured value of maximum compression force is less than the lower limit of 27 daN, proceed as follows: 1. Remove the set screw from the torque limiter (2 mm allen wrench). . Turn the adjusting nut clockwise until the set screw hole coincides exactly with the next hole in the lock washer underneath the adjusting nut. 2. Screw the set screw into its position in the adjusting nut, taking care to ensure that it enters the hole in the lock washer. It must not exert pressure on the washer. 3. Repeat the check and adjustment procedures until the measured maximum compression force is within the specification. Chapter 7 Page no. 584 JC-ELE-A-017.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) Job Card ELE A020 - Declare and Set Printers (Filming Devices) 1 Chapter 7 SUPPLIES None 2 TOOLS REQUIRED None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 20 minutes 4 SAFETY PRECAUTIONS None 5 PREREQUISITES The AWS must have been correctly installed and configured. The local network must have been correctly installed, and the Network Printers to be declared must have been correctly installed and connected to the Network. 5-1 Determine the Printer Hostname and AET When configuring a printer, the Hostname and Application Entity Title (AET) that you specify on ADS, must be the same as the hostname and AET configured on the printer by the printer manufacturer field engineer. The settings in section 7, Printer Parameters describe the default (usual) hostname and AET settings for each printer. However, check with the printer manufacturer field engineer the value of the hostname and AET that was set on the printer, and ensure that you use these same values when configuring the printer on the GE system. 5-2 GE Equipment Hostname Declaration on the Printer The hostname (in DICOM format) of the GE system must be declared on the printer so that it is permitted to print images to the printer. Work with the printer manufacturer field engineer to ensure that the GE system has been added to the permitted hosts list of the printer. The format of the hostname (in DICOM format) that needs adding to the printer is PR_, where is the hostname defined on the GE system. For example, if the hostname of the ADS workstation on a Senographe Essential system is called adsB, the hostname added to the permitted hosts list of the printer is PR_adsB. 5-3 Printer IP Address and Port Number Ensure that the following information is available before starting to install printers: • IP address and Hostname of Network printers. This information can be obtained either from the Network Administrator of the Hospital, or from the Needs assessment Form completed by the Network Champions. • DICOM Port number of Network printers. This information can be obtained from the Printer Supplier. Page no. 585 JC-ELE-A-020.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) 6 PROCEDURE 6-1 Test the Network Connection to the Printer Once a network printer is connected to the network and set with an IP address, it must respond to TCP/ IP messages from another Host on the network (e.g., the AWS). Before declaring a printer on the AWS, check the network connection: Enter the following ping command after the prompt: ping where is the IP address of the network printer (e.g. 192.100.9.5) The reply is of the following format: is alive Note: When entering the printer IP address, do not enter leading zeros in any of the four numeric fields separated by dots. For example, do not type in 192.100.009.005, but type 192.100.9.5 instead. The "alive" answer from the system means that the Network printer can be reached from the Acquisition Workstation system through the network. If the system displays "unknown host", your printer may not be correctly declared on the network. If the system displays "Network unreachable", you probably have given the printer an IP address incompatible with your Review Workstation IP address. Check that they belong to the same network, 192.100.9.X, for example. 6-2 Declare the DICOM Printers to the AWS • From the Browser, click the Tools menu button Dicom printer selection window: • • Click the Add button to display the DICOM Printer parameters window (Illustration 1). Complete the different fields according to the information given by the DICOM Printer manufacturer. For text entries, click in the required field and type the text; click check boxes to select/deselect them. Click Clear to clear all fields, Save to store the entered information, and Done to exit and return to the Printer Selection window. • Chapter 7 , then click Printer Management to display the Page no. 586 JC-ELE-A-020.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) Refer to Printer Parameters on page 590 for information on Konica 793/873, Agfa 4500M/5500/5503/ AXYS, Kodak Dryview 6800/8900/8600/8610,, Carestream 5850, Carestream Dryview 6850, Fuji FMDPL and Fuji Drypix 4000/5000/7000 printers. Note: Before using the values quoted below to configure a printer, contact the printer manufacturer FE to check the software version installed on the printer. 6-3 Set Print Annotation Level Ask the customer which print annotation model they want. Depending on the customer's requirement, set the Printing Annotations selection to the one selected, using the Annotations window in Medical Preferences. Refer to the Browser chapter in the Senographe DS Operator Manual for access to this window. Page no. 587 JC-ELE-A-020.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) ILLUSTRATION 1 - THE DICOM PRINTER PARAMETERS WINDOW Chapter 7 Page no. 588 JC-ELE-A-020.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) 6-4 Points of Consideration 6-4-1 Pixel Depth Raw images taken by the Senographe system are in 14-bits. The pixel depth in the DICOM printer parameters page defines the number of bits per pixel that are sent to the printer. • When no pixel depth (10 or 12) is selected, the default value of 8-bits per pixel are sent to the printer. • When the 10 pixel depth check box is selected, 10-bits per pixel are sent to the printer. • When the 12 pixel depth check box is selected, 12-bits per pixel are sent to the printer. Note: If the pixel depth is set to 10-bits per pixel or 12-bits per pixel, there may be problems with images printed from the Scrapbook. The recommended pixel depth setting is 8-bits per pixel. 6-4-2 Other Printer Parameters If you witness problems with printing, check with the printer manufacturer field engineer that the other printer parameters on the printer (i.e. port number, pixel size, configuration information, density, magnification type, and smoothing factor) match the parameters set on the GE system. Page no. 589 JC-ELE-A-020.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) 7 PRINTER PARAMETERS This section gives information on entries to be made in the DICOM Parameters window for printers qualified for use with the Senographe system. 7-1 Konica Printers 7-1-1 Konica 793 DICOM Printer • DICOM printer label: Any name you wish to see appearing on the Film Composer, e.g., Konica DPRO793. • Hostname: Use printer Hostname if any, or a name unique to your Network, e.g., dpro793. • Network address: A unique IP address given by the hospital Network Administrator), e.g., 3.48.16.135. • Application Entity Title (AET): Must be DPRO793 • Port number: Must be 104 • Layouts: • Film size: • • • • • • • Must be 1 x 1 ,1x2 ,2x1 , or 2 x 2 Must be 8 in x 10 in W = 4596 H = 5674 10 in x 12 in W = 5766 H = 6826 Pixel size 43.75 Configuration information Must be KC_ LUT=1 Density Must be Min: 20 Max: 400 Magnification type: Must be Cubic Smoothing factor: Must not contain any value Trim: Must be NO Printer Memory Size Must be 1024 Chapter 7 Page no. 590 JC-ELE-A-020.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) ILLUSTRATION 2 - TYPICAL KONICA 793 ENTRIES Page no. 591 JC-ELE-A-020.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) 7-1-2 Konica 873 DICOM Printer • DICOM printer label: Any name you wish to see appearing on the Film Composer, e.g., KMDRYPRO873. • Hostname: Use printer Hostname if any, or a name unique to your Network, e.g., dpro873. • Network address: A unique IP address given by the hospital Network Administrator), e.g., 3.48.16.135. • Application Entity Title (AET): Must be dpro873 • Port number: Must be 104 • Layouts: • Film size: • • • • • • • Must be 1 x 1 ,1x2 ,2x1 , or 2 x 2 Must be 8 in x 10 in W = 4596 H = 5674 10 in x 12 in W = 5766 H = 6826 Pixel size 43.75 Configuration information Must not contain any value Density Must be Min: 20 Max: 400 Magnification type: Must be Cubic Smoothing factor: Must not contain any value Trim: Must be NO Printer Memory Size Must be 1024 Chapter 7 Page no. 592 JC-ELE-A-020.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) ILLUSTRATION 3 - TYPICAL KONICA 873 ENTRIES Page no. 593 JC-ELE-A-020.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) 7-2 Agfa Printers 7-2-1 Agfa Drystar AXYS DICOM Printer • DICOM printer label: Any name you wish to see appearing on the Film Composer e.g., Agfa AXYS. • Hostname: Use printer Hostname if any, or a name unique to your Network e.g., DSAXYSM. • Network address: A unique IP address given by the hospital Network Administrator, e.g., 3.48.16.136. • Application Entity Title (AET):Default value is AXYS_M , however contact the Agfa engineer for the correct AET value to use • Port number: Must be 104 • Layouts: • Film size: • • • • • • • Must be 1 x 1 ,1x2 ,2x1 , or 2 x 2 Must be 8 in x 10 in W = 3828 H = 4958 10 in x 12 in W = 4892 H = 5890 Pixel size 50 Configuration information:Must be PERCEPTION_LUT=OEM919 Density Must be Min: no value Max: 370 Magnification type: Must be Cubic Smoothing factor: Must be 143 Trim: Must be NO Printer Memory Size Must be 40 Chapter 7 Page no. 594 JC-ELE-A-020.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) ILLUSTRATION 4 - TYPICAL AGFA AXYS ENTRIES Page no. 595 JC-ELE-A-020.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) 7-2-2 Agfa 5500/5503 DICOM Printer • DICOM printer label: Any name you wish to see appearing on the Film Composer e.g., Drystar5503. • Hostname: Use printer Hostname if any, or a name unique to your Network e.g., drystar5503. • Network address: A unique IP address given by the hospital Network Administrator, e.g., 3.48.16.136. • Application Entity Title (AET):Default value is DS5500 , however contact the Agfa engineer for the correct AET value to use • Port number: Must be 104 • Layouts: • Film size: • • • • • • • Must be 1 x 1 ,1x2 ,2x1 , or 2 x 2 Must be 8 in x 10 in W = 3828 H = 4958 10 in x 12 in W = 4892 H = 5900 Pixel size 50 Configuration information:Must be PERCEPTION_LUT=OEM919 Density Must be Min: no value Max: 370 Magnification type: Must be Cubic Smoothing factor: Must be 143 Trim: Must be NO Printer Memory Size Must be 100 Chapter 7 Page no. 596 JC-ELE-A-020.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) ILLUSTRATION 5 - TYPICAL AGFA DRYSTAR 5500/5503 ENTRIES Page no. 597 JC-ELE-A-020.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) 7-2-3 Agfa 4500M DICOM Printer • DICOM printer label: Any name you wish to see appearing on the Film Composer e.g., DS4500M. • Hostname: Use printer Hostname if any, or a name unique to your Network e.g., DS4500M. • Network address: A unique IP address given by the hospital Network Administrator, e.g., 3.48.16.136. • Application Entity Title (AET):Must be DS4500 • Port number: Must be 104 • Layouts: • Film size: • • • • • • • Must be 1 x 1 ,1x2 ,2x1 , or 2 x 2 Must be 8 in x 10 in W = 3828 H = 4958 10 in x 12 in W = 4892 H = 5900 Pixel size 50 Configuration information:Must be PERCEPTION_LUT=OEM919 Density Must be Min: no value Max: 370 Magnification type: Must be Cubic Smoothing factor: Must be 143 Trim: Must be NO Printer Memory Size Must be 40 Chapter 7 Page no. 598 JC-ELE-A-020.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) ILLUSTRATION 6 - TYPICAL AGFA DRYSTAR 4500M ENTRIES Page no. 599 JC-ELE-A-020.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) 7-3 Kodak / Carestream Printers 7-3-1 DryView 8900 DICOM Printer • DICOM printer label: Any name you wish to see appearing on the Film Composer, e.g., Kodak 8900. • Hostname: Use printer Hostname if any, or a name unique to your Network, e.g., DV8900. • Network address: A unique IP address given by the hospital Network Administrator), e.g., 3.48.16.135. • Application Entity Title (AET): Must be 8900 • Port number: Must be 5040 • Layouts: • Film size: • • • • • • • Must be 1 x 1 ,1x2 ,2x1 , or 2 x 2 Must be 8 in x 10 in W = 5056 H = 6368 10 in x 12 in W = 6368 H = 7656 Pixel size 39.08 Configuration information Must be LUT=gsdfaa0p.w8u,3 Density Must be Min: no value Max: 360 for DVM film type Max: 415 for DVM+ film type Magnification type: Must be Cubic Smoothing factor: Must be 15 Trim: Must be NO Printer Memory Size 40 (default value) Note: To match new AFSSAPS requirements (in France) for Ambient Light=1 & Illumination=4000, do not set Review Room into Review Room Management, and check with the printer manufacturer that the printer is correctly configured. Chapter 7 Page no. 600 JC-ELE-A-020.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) ILLUSTRATION 7 - TYPICAL KODAK DRYVIEW 8900 ENTRIES Page no. 601 JC-ELE-A-020.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) 7-3-2 DryView 6800 DICOM Printer • DICOM printer label: Any name you wish to see appearing on the Film Composer, e.g., Kodak 6800. • Hostname: Use printer Hostname if any, or a name unique to your Network, e.g., DV6800. • Network address: A unique IP address given by the hospital Network Administrator), e.g., 3.48.16.135. • Application Entity Title (AET): Must be DV6800 • Port number: Must be 5040 • Layouts: • Film size: • • • • • • • Must be 1 x 1 ,1x2 ,2x1 , or 2 x 2 Must be 8 in x 10 in W = 5056 H = 6368 10 in x 12 in W = 6368 H = 7656 Pixel size 39.08 Configuration information Must be LUT=gsdfaa0p.w8u,3 Density Must be Min: no value Max: 360 for DVM film type Max: 415 for DVM+ film type Magnification type: Must be Cubic Smoothing factor: Must be 15 Trim: Must be NO Printer Memory Size 40 (default value) Note: To match new AFSSAPS requirements (in France) for Ambient Light=1 & Illumination=4000, do not set Review Room into Review Room Management, and check with the printer manufacturer that the printer is correctly configured. Chapter 7 Page no. 602 JC-ELE-A-020.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) ILLUSTRATION 8 - TYPICAL KODAK DRYVIEW 6800 ENTRIES Page no. 603 JC-ELE-A-020.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) 7-3-3 DryView 5850 DICOM Printer • DICOM printer label: Any name you wish to see appearing on the Film Composer, e.g., Carestream 5850. • Hostname: Use printer Hostname if any, or a name unique to your Network, e.g., DV5850DRE. • Network address: A unique IP address given by the hospital Network Administrator), e.g., 3.48.15.141. • Application Entity Title (AET): Must be DV5850 • Port number: Must be 5040 • Layouts: • Film size: • • • • • • • Must be 1 x 1 ,1x2 ,2x1 , or 2 x 2 Must be 8 in x 10 in W = 3848 H = 4864 10 in x 12 in W = 4864 H = 5880 Pixel size 50 Configuration information Must be LUT=gsdfaa0p.w8u,3 Density Must be Min: 20 Max: 360 for DVM film type Max: 415 for DVM+ film type Magnification type: Must be Cubic Smoothing factor: Must be 15 Trim: Must be NO Printer Memory Size 40 (default value) Note: To match new AFSSAPS requirements (in France) for Ambient Light=1 & Illumination=4000, do not set Review Room into Review Room Management, and check with the printer manufacturer that the printer is correctly configured. Chapter 7 Page no. 604 JC-ELE-A-020.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) ILLUSTRATION 9 - TYPICAL CARESTREAM DRYVIEW 5850 ENTRIES Page no. 605 JC-ELE-A-020.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) 7-3-4 DryView 6850 DICOM Printer • DICOM printer label: Any name you wish to see appearing on the Film Composer, e.g., Carestream 6850. • Hostname: Use printer Hostname if any, or a name unique to your Network, e.g., DV6850DRE. • Network address: A unique IP address given by the hospital Network Administrator), e.g., 3.249.15.142. • Application Entity Title (AET): Must be DV6850 • Port number: Must be 5040 • Layouts: • Film size: • • • • • • • Must be 1 x 1 ,1x2 ,2x1 , or 2 x 2 Must be 8 in x 10 in W = 4924 H = 6224 10 in x 12 in W = 6224 H = 7526 Pixel size 39.08 Configuration information Must be LUT=gsdfaa0p.w8u,3 Density Must be Min: 20 Max: 360 for DVM film type Max: 415 for DVM+ film type Magnification type: Must be Cubic Smoothing factor: Must be 15 Trim: Must be NO Printer Memory Size 40 (default value) Note: To match the new AFSSAPS requirements (in France) for Ambient Light=1 & Illumination=4000, do not set Review Room into Review Room Management, and check with the printer manufacturer that the printer is correctly configured. Chapter 7 Page no. 606 JC-ELE-A-020.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) ILLUSTRATION 10 - TYPICAL CARESTREAM DRYVIEW 6850 ENTRIES Page no. 607 JC-ELE-A-020.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) 7-3-5 DryView 8610 DICOM printer This printer is already in the install base and can no longer be purchased. It is replaced by the Kodak DryView 8900 DICOM printer. However, if you need to declare these printers, the settings are as follows: • DICOM printer label: Any name you wish to see appearing on the Film Composer, e.g., Kodak 8610. • Hostname: Use printer Hostname if any, or a name unique to your Network, e.g., kodak1printer. • Network address: A unique IP address given by the hospital Network Administrator), e.g., 3.48.16.135. • Application Entity Title (AET): Must be IMN_9410 • Port number: Must be 1024 • Layouts: • • • • • • • • Film size: Must be 8 in x 10 in W = 5192 H = 6201 Pixel size 38.75 Configuration information Must be LUT=0,3 Density Must be Min : no value Max : 350 Magnification type: Must be Cubic Smoothing factor: Must be 1 Trim: Must be NO Printer Memory Size Must be 80 Chapter 7 Must be 1 x 1 ,1x2 ,2x1 , or 2 x 2 Page no. 608 JC-ELE-A-020.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) ILLUSTRATION 11 - TYPICAL KODAK DRYVIEW 8610 ENTRIES Page no. 609 JC-ELE-A-020.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) 7-3-6 DryView 8600 DICOM printer This printer is already in the install base and can no longer be purchased. It is replaced by the Kodak DryView 8900 DICOM printer. However, if you need to declare these printers, the settings are as follows: • DICOM printer label: Any name you wish to see appearing on the Film Composer, e.g., Kodak 8600. • Hostname: Use printer Hostname if any, or a name unique to your Network, e.g., kodak1printer. • Network address: A unique IP address given by the hospital Network Administrator), e.g., 3.48.16.135. • Application Entity Title (AET): Must be IMN_9410 • Port number: Must be 1024 • Layouts: • • • • • • • • Film size: Must be 8 in x 10 in W = 5192 H = 6201 Pixel size 38.75 Configuration information Must be LUT=0,3 Density Must be Min : no value Max : no value Magnification type: Must be Cubic Smoothing factor: Must not contain any value Trim: Must be NO Printer Memory Size 40 (default value) Chapter 7 Must be 1 x 1 ,1x2 ,2x1 , or 2 x 2 Page no. 610 JC-ELE-A-020.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) ILLUSTRATION 12 - TYPICAL KODAK DRYVIEW 8600 ENTRIES Page no. 611 JC-ELE-A-020.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) 7-4 Fuji Printers 7-4-1 Fuji Drypix 4000/5000/7000 DICOM Printer • DICOM printer label: Any name you wish to see appearing on the Film Composer, e.g., Fuji Drypix 4000, Fuji Drypix 5000, or Fuji Drypix 7000. • Hostname: Must be drypixstd • Network address: A unique IP address given by the hospital Network Administrator), e.g., 3.48.16.135. • Application Entity Title (AET): Must be DRYPIXSTD • Port number: Must be 104 • Layouts: • Film size: • • • • • • • Must be 1 x 1 ,1x2 ,2x1 , or 2 x 2 Must be 8 in x 10 in W = 3960 H = 4890 10 in x 12 in W = 4790 H = 5900 Pixel size 100 Configuration information Must not contain any value Density Must be Min: no value Max: no value Magnification type: Must be CUBIC Smoothing factor: Must not contain any value Trim: Must be NO Printer Memory Size 40 (default value) Chapter 7 Page no. 612 JC-ELE-A-020.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) ILLUSTRATION 13 - TYPICAL FUJI DRYPIX 4500, 5000 AND 7000 ENTRIES Page no. 613 JC-ELE-A-020.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) 7-4-2 Fuji FMDPL DICOM printers • DICOM printer label: Any name you wish to see appearing on the Film Composer e.g., Fuji FMDPL. • Hostname: Use printer Hostname if any, or a name unique to your Network e.g., Fuji1FMDPL. • Network address: A unique IP address given by the hospital Network Administrator, e.g., 3.48.16.135. • Application Entity Title (AET):Must be FMDPLFINE • Port number: Must be 104 • Layouts: • Film size: • • • • • • • ,2x1 , or 2 x 2 Must be 8 in x 10 in W = 3907 11 in x 14 in W = 5075 Pixel size 50 Configuration information:Must be 1 Density: Must be Min : 20 Max : 300 Magnification type: Must be Cubic Smoothing factor: Must not contain any value Trim: Must be NO Printer Memory Size 200 H = 4931 H = 7199 Chapter 7 Must be 1 x 1 ,1x2 Page no. 614 JC-ELE-A-020.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) ILLUSTRATION 14 - TYPICAL FUJI FMDPL ENTRIES Page no. 615 JC-ELE-A-020.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) 7-5 Sony Printers 7-5-1 SONY UP-DF750 Printer • DICOM printer label: Any name you wish to see appearing on the Film Composer, e.g., SONY UPDF750. • Hostname: Use printer Hostname if any, or a name unique to your Network, e.g., DF750. • Network address: A unique IP address given by the hospital Network Administrator), e.g., 3.48.16.135. • Application Entity Title (AET): Must be UPDF750M • Port number: Must be 104 • Layouts: • Film size: • • • • • • • Must be 1 x 1 ,1x2 ,2x1 , or 2 x 2 Must be 8 in x 10 in W = 4736 H = 5856 10 in x 12 in W = 5952 H = 7040 Pixel size 42.05 Configuration information Must not contain any value Density Must be Min: 20 Max: 380 Magnification type: Must be Cubic Smoothing factor: Must not contain any value Trim: Must be NO Printer Memory Size 20 Note: In order for the Sony DP-DF750 to work with the GE mammography image size produced by the Senographe system, the printer default settings must be changed during the installation. The default Frame Type value of “Caption2” must be changed to “M-Wide2” by the Sony printer technician. Chapter 7 Page no. 616 JC-ELE-A-020.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) ILLUSTRATION 15 - TYPICAL SONY UP-DF750 ENTRIES Page no. 617 JC-ELE-A-020.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A020 - Declare and Set Printers (Filming Devices) 8 REVIEW ROOM DECLARATION A review room represents virtually the lighting review conditions for a printed film. It consists in measuring two values: the Ambient light and the Film Box light and associate them to a specific printer. The selected printer then uses these two values to build dynamically the right printing LUT corresponding to the environmental review conditions. 1. From the Browser, click the Tools menu button The Review Room Selection window appears: and click Review Room Management. 2. Click the Add button. The Review_rooms_parameters window appears. 3. In the Review Room Label field, type the name you want to give to the review room. This is a userdefined field (for example, enter MyRoom1). ! Notice: Do not use the following characters in the name: space, greater than (>) and less than ( To make a selection ............................. ................................................. Networked : X Yes No 2. At the DHCP screen, ensure that No is selected for the Use DHCP option, and press the key to continue. ‐ ‐ ‐ ‐‐ DHCP On this screen ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ … … … … … … … … … … … … …. Use DHCP Yes X No 3. At the Primary Network Interface screen, ensure that eri0 is selected for the Primary Network Interface and press the key to continue. Then press the key to continue. ‐ Primary Network Interface ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ On this screen ......................... Primary Network Interface X eri0 ce0 Chapter 7 Page no. 628 JC-ELE-A-021.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 4. At the Hostname screen, type the Hostname to be used for the Acquisition Workstation in the Hostname field, and press when done. Then press the key to continue. - Hostname - - - - - - - - - - - - - - - - - - - - - - - - - - - On this screen ................................. A host name must be ............................. ................................................. Hostname : Note: The Hostname will automatically be used as the DICOM A.E. Title for the workstation. If there is more than one Senographe system on the hospital site, the names chosen must clearly differentiate between them. For example, by include the unit number or name. Do not use the following characters in the Hostname: ! $ ” ‘ ’ { } [ ] * @ # ? ^ _ / etc. ONLY USE ALPHANUMERIC CHARACTERS WITHOUT SPACES. It is also possible to use the characters - (dash) and . (dot). Ensure that the Hostname is no more than 12 characters long. The Hostname must be the same value as the Station Name that is defined in Job Card ELE A013 - AWS Configuration on page 573. 5. At the IP Address screen, type the external IP address to be used for the Acquisition Workstation in the IP address field, and press the key when done. Then press the key to continue. - IP Address - - - - - - - - - - - - - - - - - - - - - - - - - - On this screen ................................. IP addresses must ............................. ................................................. IP address : 6. At the Subnets screen, ensure that Yes is selected for the System part of a subnet option, and press the key to continue. - Subnets - - - - - - - - - - - - - - - - - - - - - - - - - - - On this screen ................................. > To make a selection ............................. ................................................. System part of a subnet : X Yes No Page no. 629 JC-ELE-A-021.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 7. A Netmask screen appears with a default netmask of 255.255.255.0.. - Netmask - - - - - - - - - - - - - - - - - - - - - - - - - - On this screen ................................. 255.255.255.0 Netmask : Specify an appropriate netmask as follows: • lf the Hospital Network Administrator has given you a different netmask to the default value of 255.255.255.0, erase the displayed default Netmask by back-spacing over it. Then type in the new Netmask address. • If the Hospital Network Administrator has not given you a different netmask to the default value of 255.255.255.0, leave the default Netmask of 255.255.255.0 as is. Press the key to continue. 8. At the IPV6 screen, ensure that No is selected for the Use IPV6 option, and press the key to continue. ‐ ‐ ‐ ‐‐ IPV6 On this screen ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ …………………………………. Use IPV6 Yes X No 9. At the Confirmation information screen, ensure that the correct information appears for the eri0 network interface, and press the key to continue. - Confirm information - - - - - - - - - - - - - - - - - - - - - > Confirm the following ........................... ................................................. Host name : XXXXX Networked : Yes Primary Network Interface : eri0 IP address : X.X.X.X A screen indicating a delay may appear while the settings for the eri0 network interface are being stored. Just a moment 10. At the Kerberos Security screen, ensure that No is selected for the Use Kerberos Security option, Chapter 7 Page no. 630 JC-ELE-A-021.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration and press the key to continue ‐ Kerberos Security ------------------------------ …………………………………….. On this screen Use Kerberos Security Yes X No 11. At the Name service screen, use the Down arrow key to move to None Name Service option, then press to confirm the selection. Then press the key to continue - Name service - - - - - - - - - - - - - - - - - - - - - - - - - On this screen ................................. > To make a selection ............................. ................................................. Name Service : NIS + NIS (formerly Other X None Note: Do not select NIS+ or NIS Client services. None is the primary selection. 12. At the Time Zone screen, use the Up or Down arrow keys to select the Other - Offset from GMT Page no. 631 JC-ELE-A-021.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration region. Press to confirm the selection, and then press the key to continue. ‐ Time Zone ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ On this screen ................................. > To make a selection ............................. Regions : Africa Asia, Eastern --- United States X Other - Offset from GMT Other 13. At the Offset from GMT screen that appears, type 0 for the offset the press to confirm the offset value. Press the key to continue. Offset From GMT Specify the number of hours difference between .... 0 Chapter 7 Page no. 632 JC-ELE-A-021.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 14. A Date and Time screen appear with some existing date and time settings. - Date and Time - - - - - - - - - - - - - - - - - - - - - - - - > Accept the default ............................. ................................................. Date and time : mm/dd/yy hh:mm Year (4 digits) : 2004 Month (1-12) : XX Day (1-31) : XX Hour (0-23) : XX Minute (0-59) : XX Proceed as follows: • If the date and time settings are incorrect, use the Up or Down arrow keys to move to the field to be modified (as applicable). Type in the correct value, then press to confirm the new value and move to the next field. When you are happy with the date and time settings, press the key to continue. • If the date and time settings are correct, press the key to continue. 15. The Root Password screen appears allowing you to change the current root password for the Acquisition Workstation from the default value of operator. On this screen, you can create a root password ..... A root password ................................. > If you do not want ........................... ................................................. Root password : Press Return to continue. If you wish to change it, type in the new password and press the key when done. The password you type is not displayed. The default password for root is operator. Note: Ensure that the caps-lock key is not engaged before entering the password. If you change the password, the system asks you to re-enter the new password. If there is a difference between the two entries, the system will request it again. When the password has been correctly changed, or if you press without changing the password, the system reboots. Log in to the system according to Login on page 652. Page no. 633 JC-ELE-A-021.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 7-3 Network Configuration for V3 Control Stations For V3 Control Stations, proceed as follows to complete the network configuration. 1. At the Network Connectivity screen, ensure that Yes is selected for the Networked option, and press the key to continue. Network Connectivity Specify Yes if the system is connected to .................. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Networked ‐ ‐ ‐ ‐ ‐ X X Yes No ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ 2. At the Configure Multiple Network Interface screen, ensure that only nge0 is selected from the list of Network Interfaces. Press the key to confirm the selection, and then press the key to continue. t e r f a c e s C o n f i g u r e M u l t i p l e N e t w o r k I n Multiple network interfaces have been .................. Note : You must choose at least one interface to configure . Network Interfaces ‐ ‐ ‐ ‐ X ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ nge0 nge1 3. At the DHCP for nge0 screen ensure, that No is selected for the Use DHCP for nge0 option, and press the key to continue. D HCP fo r nge 0 Sp ecify whethe r or no t ... Use DHCP for nge 0 ‐ ‐ ‐ ‐ ‐ ‐ Yes XX Chapter 7 No ‐ ‐ ‐ ‐ Page no. 634 JC-ELE-A-021.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 4. At the Hostname for nge0 screen, type the Hostname to be used for the Acquisition Workstation in the Host name for nge0 field. Press when done, and then press the key to continue. Host Name for nge 0 Enter the host name which ... A host name must have at ... Host name for nge 0 Note: The Hostname will automatically be used as the DICOM A.E. Title for the workstation. If there is more than one Senographe system on the hospital site, the names chosen must clearly differentiate between them. For example, by include the unit number or name. Do not use the following characters in the Hostname: ! $ ” ‘ ’ { } [ ] * @ # ? ^ _ / etc. ONLY USE ALPHANUMERIC CHARACTERS WITHOUT SPACES. It is also possible to use the characters - (dash) and . (dot). Ensure that the Hostname is no more than 12 characters long. The Hostname must be the same value as the Station Name that is defined in Job Card ELE A013 - AWS Configuration on page 573. 5. At the IP Address for nge0 screen, type the external IP address to be used for the Acquisition Workstation in the IP address for nge0 field. Press the key when done, and then press the key to continue. IP Address for nge 0 Enter the Internet Protocol (IP) address for this ... IP addresses contain ... IP address for nge 0 6. At the Subnet for nge0 screen, ensure that Yes is selected for the System part of a subnet option, Page no. 635 JC-ELE-A-021.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration and press the key to continue. Subnet for nge 0 On this screen you must specify whether this system is ... System part of a subnet ‐ ‐ X ‐ ‐ ‐ ‐ Yes No ‐ ‐ ‐ ‐ ‐ ‐ ‐ 7. A Netmask screen appears with a default netmask of 255.255.255.0.. Netmask for nge 0 On this screen you must specify the netmask for your ... ......................... Netmask for nge 0 255.255.255.0 Specify an appropriate netmask as follows: • lf the Hospital Network Administrator has given you a different netmask to the default value of 255.255.255.0, erase the displayed default Netmask by back-spacing over it. Then type in the new Netmask address. • If the Hospital Network Administrator has not given you a different netmask to the default value of 255.255.255.0, leave the default Netmask of 255.255.255.0 as is. Press the key to continue. 8. At the IPv6 for nge0 screen, ensure that No is selected for the Use IPV6 option, and press the key to continue. IPv6 for nge0 Specify whether or not you want to enable IPv6, the next ... ......................... Enable IPV6 for nge0 -------------------Yes XX No 9. At the Set the Default Route for nge0 screen, ensure that None is selected for the Default Route for Chapter 7 Page no. 636 JC-ELE-A-021.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration nge0 option, and press the key to continue. Set the Default Route for nge0 To specify the default route, you can let the software ... ......................... Default Route for nge0 ------------------- Detect one upon reboot Specify one X X None 10. At the Confirmation Information for nge0 screen, ensure that the correct information appears for the nge0 network interface, and press the key to continue. Confirm information for nge0 > Confirm the following information. If it is correct ... ......................... Networked: Yes Use DHCP: No Host name: XXXXXX IP address: N.N.N.N System part of a subnet: Yes Netmask: N.N.N.N Enable IPv6: No Default Route: None A screen indicating a delay may appear while the settings for the nge0 network interface are being stored. Just a moment 11. At the Configure Security Policy screen, ensure that No is selected for the Configure Kerberos Secu- Page no. 637 JC-ELE-A-021.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration rity option, and press the key to continue. Configure Security Policy: Specify Yes if the system will use the Kerberos security mechanism. Specify No if this system will use standard UNIX security. Configure Kerberos Security --------------------------Yes XX Chapter 7 No Page no. 638 JC-ELE-A-021.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 12. At the Confirm Information screen that appears displaying the Kerberos Security settings, press the key to continue. Confirm Information > Confirm the following information. If it is correct ... ......................... Configure Kerberos Security: No 13. At the Name Service screen, use the Down arrow key to move to None Name service option, then press to confirm the selection. Then press the key to continue Name Service On this screen you must provide name service information.... ......................... Name service ----------- NIS+ NIS DNS LDAP XX None Note: Do not select NIS+ or NIS services. NIS+ is the primary selection. Page no. 639 JC-ELE-A-021.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 14. At the Confirm Information screen that appears displaying the Name Service settings, press the key to continue. Confirm Information > Confirm the following information. If it is correct ... ......................... Name service: None 15. At the Time Zone screen, use the Up or Down arrow keys to select the Other - offset from GMT region. Press to confirm the selection, then press the key to continue. Time Zone On this screen ................................. > To make a selection ............................. Continents and Oceans: ---------------------Antartica Arctic Ocean Aisa Atlantic Ocean Australia Europe Indian Ocean Pacific Ocean XX Other - offset from GMT Other - specify time zone file Chapter 7 Page no. 640 JC-ELE-A-021.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 16. At the Offset from GMT screen that appears, type 0 for the offset the press to confirm the offset value. Press the key to continue. Offset From GMT Specify the number of hours difference between .... 0 17. A Date and Time screen appear with some existing date and time settings. Date and Time > Accept the default date and time or enter new values. Date and time: 2007-06-09 11:33 Year (4 digits): 2007 Month (1-12): 06 Day (1-31): 09 Hour (0-23): 11 Minute: 33 Proceed as follows: • If the date and time settings are incorrect, use the Up or Down arrow keys to move to the field to be modified (as applicable). Type in the correct value, then press to confirm the new value and move to the next field. When you are happy with the date and time settings, press the key to continue. • If the date and time settings are correct, press the key to continue. Page no. 641 JC-ELE-A-021.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 18. At the Confirm Information screen that appears displaying the date and time settings, press the key to continue. Confirm Information > Confirm the following information. If it is correct ... ......................... Time zone: GMTn Date and time: 2007-06-09 11:33 19. The Root Password screen appears prompting you to specify a root password for the Acquisition Workstation. Root Password Please enter the root password for this system. The root password may contain alphanumeric and special characters. For security, the password will not be displayed on the screen as you type it. > If you do not want a root password leave both entries blank. Root password: Root password: Type the required root password (usually operator) in both the Root password fields and press the key when done. The password you type is not displayed. The default password for root is operator. Note: Ensure that the caps-lock key is not engaged before entering the password. If there is a difference between the two entries, the system will request it again. Press the key to continue. 20. A System identification screen appears. System identification is completed. This system is configured with NFS version 4, which uses a domain name that is automatically derived from the system’s name services. The derived domain name is sufficient for most configurations. In a few cases, mounts that cross different domains might cause files to be owned by ‘nobody’ due to the lack of a common domain name. Do you need to override the system’s default NFS version 4 domain name (yes/no) ? [no] : _ At the prompt, press the key to accept the default answer (no). The system reboots. Log in to the system according to Login on page 652. Chapter 7 Page no. 642 JC-ELE-A-021.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 7-4 Network Configuration for V4 Control Stations For V4 Control Stations, proceed as follows to complete the network configuration. 1. At the Network Connectivity screen, ensure that Yes is selected for the Networked option, and press the key to continue. Network Connectivity Specify Yes if the system is connected to .................. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Networked ‐ ‐ ‐ ‐ X X ‐ Yes ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ No 2. At the Configure Multiple Network Interface screen, ensure that only e100g0 is selected from the list of Network Interfaces. Press the key to confirm the selection, and then press the key to continue. t e r f a c e s C o n f i g u r e M u l t i p l e N e t w o r k I n Multiple network interfaces have been .................. Note : You must choose at least one interface to configure . Network Interfaces ‐ ‐ X ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ e1000g0 b c m e 0 3. At the DHCP for e1000g0 screen ensure, that No is selected for the Use DHCP for e1000g0 option, and press the key to continue. DHCP for e1000g0 Specify whether or not ... Use DHCP for e 1000g 0 ‐ ‐ ‐ ‐ ‐ ‐ Yes XX No ‐ ‐ ‐ ‐ Page no. 643 JC-ELE-A-021.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 4. At the Hostname for e1000g0 screen, type the Hostname to be used for the Acquisition Workstation in the Host name for e1000g0 field. Press when done, and then press the key to continue. Host Name for e 1000g0 Enter the host name which ... A host name must have at ... Host name for e 1000g0 Note: The Hostname will automatically be used as the DICOM A.E. Title for the workstation. If there is more than one Senographe system on the hospital site, the names chosen must clearly differentiate between them. For example, by include the unit number or name. Do not use the following characters in the Hostname: ! $ ” ‘ ’ { } [ ] * @ # ? ^ _ / etc. ONLY USE ALPHANUMERIC CHARACTERS WITHOUT SPACES. It is also possible to use the characters - (dash) and . (dot). Ensure that the Hostname is no more than 12 characters long. The Hostname must be the same value as the Station Name that is defined in Job Card ELE A013 - AWS Configuration on page 573. 5. At the IP Address for e1000g0 screen, type the external IP address to be used for the Acquisition Workstation in the IP address for e1000g0 field. Press the key when done, and then press the key to continue. IP Address for e 1000g0 Enter the Internet Protocol (IP) address for this ... IP addresses contain ... IP address for e 1000g0 6. At the Subnet for e1000g0 screen, ensure that Yes is selected for the System part of a subnet option, Chapter 7 Page no. 644 JC-ELE-A-021.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration and press the key to continue. Subnet for e 1000g0 On this screen you must specify whether this system is ... System part of a subnet ‐ ‐ ‐ X ‐ ‐ ‐ Yes No ‐ ‐ ‐ ‐ ‐ ‐ ‐ 7. A Netmask screen appears with a default netmask of 255.255.255.0.. Netmask for e 1000g0 On this screen you must specify the netmask for your ... ......................... Netmask for e 1000g0 255.255.255.0 Specify an appropriate netmask as follows: • lf the Hospital Network Administrator has given you a different netmask to the default value of 255.255.255.0, erase the displayed default Netmask by back-spacing over it. Then type in the new Netmask address. • If the Hospital Network Administrator has not given you a different netmask to the default value of 255.255.255.0, leave the default Netmask of 255.255.255.0 as is. Press the key to continue. 8. At the IPv6 for e1000g0 screen, ensure that No is selected for the Use IPV6 option, and press the key to continue. IPv6 for e1000g0 Specify whether or not you want to enable IPv6, the next ... ......................... Enable IPV6 for e1000g0 ----------------------Yes XX No 9. At the Set the Default Route for e1000g0 screen, ensure that None is selected for the Default Route Page no. 645 JC-ELE-A-021.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration for e1000g0 option, and press the key to continue. Set the Default Route for e1000g0 To specify the default route, you can let the software ... ......................... Default Route for e1000g0 ------------------------ Detect one upon reboot Specify one X X None 10. At the Confirmation Information for e1000g0 screen, ensure that the correct information appears for the e1000g0 network interface, and press the key to continue. Confirm information for e1000g0 > Confirm the following information. If it is correct ... ......................... Networked: Yes Use DHCP: No Host name: XXXXXX IP address: N.N.N.N System part of a subnet: Yes Netmask: N.N.N.N Enable IPv6: No Default Route: None A screen indicating a delay may appear while the settings for the e1000g0 network interface are being stored. Just a moment 11. At the Configure Security Policy screen, ensure that No is selected for the Configure Kerberos Secu- Chapter 7 Page no. 646 JC-ELE-A-021.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration rity option, and press the key to continue. Configure Security Policy: Specify Yes if the system will use the Kerberos security mechanism. Specify No if this system will use standard UNIX security. Configure Kerberos Security --------------------------Yes XX No Page no. 647 JC-ELE-A-021.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 12. At the Confirm Information screen that appears displaying the Kerberos Security settings, press the key to continue. Confirm Information > Confirm the following information. If it is correct ... ......................... Configure Kerberos Security: No 13. At the Name Service screen, use the Down arrow key to move to None Name service option, then press to confirm the selection. Then press the key to continue Name Service On this screen you must provide name service information.... ......................... Name service ----------- NIS+ NIS DNS LDAP XX None Note: Do not select NIS+ or NIS services. NIS+ is the primary selection. Chapter 7 Page no. 648 JC-ELE-A-021.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 14. At the Confirm Information screen that appears displaying the Name Service settings, press the key to continue. Confirm Information > Confirm the following information. If it is correct ... ......................... Name service: None 15. At the NFSv4 Domain Name screen, use the Up or Down arrow keys to select the Use the NFSv4 domain derived by system option. Press to confirm the selection, then press the key to continue. NFSv4 Domain Name NFS version 4 uses a domain name .... ......... ......... ......... The current NFSv4 default domain is: « » NFSv4 Domain Configuration ---------------------------------------------[X] Use the NFSv4 domain derived by the system [ ] Specify a different NFSv4 domain Page no. 649 JC-ELE-A-021.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 16. At the Confirm Information for NFSv4 Domain screen that appears, press the key to continue. Confirm Information for NFSv4 Domain correct, press F2; > Confirm the following information. If it is to change any information, press F4. NFSv4 Domain Name: > 17. At the Time Zone screen, use the Up or Down arrow keys to select the Other - offset from GMT region. Press to confirm the selection, then press the key to continue. Time Zone On this screen ................................. > To make a selection ............................. Continents and Oceans: ---------------------Antartica Arctic Ocean Aisa Atlantic Ocean Australia Europe Indian Ocean Pacific Ocean XX Other - offset from GMT Other - specify time zone file Chapter 7 Page no. 650 JC-ELE-A-021.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 18. At the Offset from GMT screen that appears, type 0 for the offset the press to confirm the offset value. Press the key to continue. Offset From GMT Specify the number of hours difference between .... 0 19. A Date and Time screen appear with some existing date and time settings. Date and Time > Accept the default date and time or enter new values. Date and time: 2007-06-09 11:33 Year (4 digits): 2007 Month (1-12): 06 Day (1-31): 09 Hour (0-23): 11 Minute: 33 Proceed as follows: • If the date and time settings are incorrect, use the Up or Down arrow keys to move to the field to be modified (as applicable). Type in the correct value, then press to confirm the new value and move to the next field. When you are happy with the date and time settings, press the key to continue. • If the date and time settings are correct, press the key to continue. Page no. 651 JC-ELE-A-021.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 20. At the Confirm Information screen that appears displaying the date and time settings, press the key to continue. Confirm Information > Confirm the following information. If it is correct ... ......................... Time zone: GMTn Date and time: 2007-06-09 11:33 21. The Root Password screen appears prompting you to specify a root password for the Acquisition Workstation. Root Password Please enter the root password for this system. The root password may contain alphanumeric and special characters. For on the screen as you type it. security, the password will not be displayed > If you do not want a root password leave both entries blank. Root password: Root password: Type the required root password (usually operator) in both the Root password fields and press the key when done. The password you type is not displayed. The default password for root is operator. Note: Ensure that the caps-lock key is not engaged before entering the password. If there is a difference between the two entries, the system will request it again. Press the key to continue. 22. When the configuration is complete, a System identification message appears. System identification is completed. The system then automatically reboots. Log in to the system according to Login on page 652. 7-5 • • • Login The configuration process is now complete. On completion of the boot sequence, the console login: prompt appears. Login with the username sdc, and press the key at the password prompt, to restart the system. Chapter 7 Page no. 652 JC-ELE-A-021.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 8 DECLARE A ROUTER To declare a router you must create file called S93route in the /etc/rc2.d directory and add some lines which declare the router. Each time the system boots the information in the /etc/rc2.d/S93route file is processed automatically and the router is automatically declared. Use the following steps to declare a router: 1. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 2. Log in as root as follows: a. At the ADS prompt enter: su b. When requested to specify the root password, enter: operator 3. Ensure that the /etc/rc2.d/S93route file exists, by entering: touch /etc/rc2.d/S93route 4. Allow the /etc/rc2.d/S93route file to be written to, by entering: chmod ou+w /etc/rc2.d/S93route 5. Exit as root user to return to sdc user, by entering: exit You are returned to the command prompt as sdc user. 6. Open the /etc/rc2.d/S93route file with the textedit command, by entering: textedit /etc/rc2.d/S93route The /etc/rc2.d/S93route file appears in an X-Windows based TextEdit application window. 7. In the TextEdit application window, type the following four lines (separated by carriage returns): #!/bin/sh # Section for routing echo Starting route service route add net where is the address to be accessed through the gateway, and is the IP of the gateway (router) indicated by the administrator. To calculate the network number (with relation to the network mask) you can use this link to a network/node calculator: http://library.mobrien.com/net.shtml or http://www.subnetonline.com/subcalc/ subnet9.html Note: Typing the "echo" lines help you to locate any possible faults during boot in case of mistyping the router information. 8. Save the /etc/rc2.d/S93route file (File > Save) and double click the TextEdit window to exit the editor. 9. Log in as root as follows: a. At the ADS prompt enter: su b. When requested to specify the root password, enter: operator Page no. 653 JC-ELE-A-021.fm button in the top left of the Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 10. Make the /etc/rc2.d/S93route file non-writable by entering: chmod o-w /etc/rc2.d/S93route 11. Reboot the system for the changes to take effect by entering: reboot 9 CHANGE AUTO NEGOTIATION OF NETWORK INTERFACE The workstation SunBlade 150 computer on V1/V2 Control Stations uses a network interface on the motherboard which is called "eri". By default the eri interface is configured for: auto negotiation = yes, and a maximum speed up to 100 Mbit/s full duplex negotiated by the workstation. The workstation U20 computer on V3 Control Stations uses a network interface on the motherboard which is called "nge0". By default the nge0 interface is configured for: auto negotiation = yes, and a maximum speed up to 1000 Mbit/s full duplex negotiated by the workstation. The workstation Z400 computer on V4 Control Stations uses a network interface on the motherboard which is called "e1000g0". By default the e1000g0 interface is configured for: auto negotiation = yes, and a maximum speed up to 1000 Mbit/s full duplex negotiated by the workstation. 9-1 Querying the Current Network Interface Settings You can read the current settings of the Network Interface at any time by using the following steps: 1. Log in as root as follows: a. At the ADS prompt enter: su b. When requested to specify the root password, enter: operator 2. Get the current auto negotiation mode settings as follows: For V1/V2 Control Stations, enter: ndd -get /dev/eri adv_autoneg_cap For V3 Control Stations, enter: ndd -get /dev/nge0 adv_autoneg_cap For V4 Control Stations, enter: ndd -get /dev/e1000g0 adv_autoneg_cap If the system is running in auto negotiation mode the command line responds with the value 1. If the system is not running in auto negotiation mode the command line responds with the value 0. Chapter 7 Page no. 654 JC-ELE-A-021.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 9-2 Disabling Auto Negotiation and Reducing the Speed of the Network Interface By default, the Control Station is delivered with auto-negotiation enabled on the network interface eri0/nge0/e1000g0. Not all hospital switches (or their ports) support auto-negotiation. In the case that the hospital switch does not support auto-negotiation, you must disable the network interface eri0/nge0/ e1000g0 auto-negotiation capabilities via a command that includes adv_autoneg_cap 0 (see procedures below). Once auto-negotiation is disabled, the network interface eri0/nge0/e1000g0 operates at its fasted possible speed unless you have disabled that speed before disabling the network interface auto-negotiation capabilities. If the operating speed of the network interface eri0/nge0/e1000g0 remains greater than that of the hospital switch port which is connected to Control Station, communication with the hospital network may not be possible. Table 1 summarizes the different network interface speeds, their probability that they work with the hospital switch, and the command used to disable the appropriate speed. If you are disabling auto-negotiation, you must consult the hospital network administrator to determine the maximum speed supported by the hospital switch port connected to the Control Station. Any speeds that are not supported by the hospital switch port must be disabled on the network interface eri0/nge0/e1000g0 before disabling the autonegotiation capabilities. TABLE 1 - POSSIBLE NETWORK INTERFACE SPEEDS Network interface speed Probability it works with hospital switch 1000 Mbit/s Full Duplex Maybe ndd command used to disable network interface speed (via command line or S93route file) V1/V2: Not applicable, since 1000 Mbit/s not possible V3: ndd -set /dev/nge0 adv_1000fdx_cap 0 V4: ndd -set /dev/e1000g0 adv_1000fdx_cap 0 1000 Mbit/s Half Duplex Maybe V1/V2: Not applicable, since 1000 Mbit/s not possible V3: ndd -set /dev/nge0 adv_1000hdx_cap 0 V4: Not Applicable - Mode does not exist 100 Mbit/s Full Duplex Probably V1/V2: ndd -set /dev/eri adv_100fdx_cap 0 V3: ndd -set /dev/nge0 adv_100fdx_cap 0 V4: ndd -set /dev/e1000g0 adv_100fdx_cap 0 100 Mbit/s Half Duplex Probably V1/V2: ndd -set /dev/eri adv_100hdx_cap 0 V3: ndd -set /dev/nge0 adv_100hdx_cap 0 V4: ndd -set /dev/e1000g0 adv_100hdx_cap 0 10 Mbit/s Full Duplex Usually V1/V2: ndd -set /dev/eri adv_10fdx_cap 0 V3: ndd -set /dev/nge0 adv_10fdx_cap 0 V4: ndd -set /dev/e1000g0 adv_10fdx_cap 0 10 Mbit/s Half Duplex Definitely V1/V2: ndd -set /dev/eri adv_10hdx_cap 0 V3: ndd -set /dev/nge0 adv_10hdx_cap 0 V4: ndd -set /dev/e1000g0 adv_10hdx_cap 0 Page no. 655 JC-ELE-A-021.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 9-2-1 Determining the Maximum Speed Supported by Hospital Switch If the hospital network engineer does not know the maximum speed supported by the hospital network switch, use the following steps to determine the maximum speed supported by the hospital network switch: 1. Ask the hospital network engineer for an IP address of a known node on the network that is alive and reachable by a network ping command. 2. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 3. Log in as root as follows: a. At the ADS prompt enter: su b. When requested to specify the root password, enter: operator 4. Disable the Senographe firewall, by entering: /etc/rc2.d/S65ipfboot stop 5. Set the eri0/nge0/e1000g0 interface auto-negotiation capabilities to no (i.e. 0) as follows: For V1/V2 Control Stations, enter: ndd -set /dev/eri adv_autoneg_cap 0 For V3 Control Stations, enter: ndd -set /dev/nge0 adv_autoneg_cap 0 For V4 Control Stations, enter: ndd -set /dev/e1000g0 adv_autoneg_cap 0 6. Ping the IP address given to you by the hospital network engineer, by entering: ping • If the ping test works, all speeds are supported and only auto-negotiation is not supported. • If the ping test fails, the highest supported speed needs determining - go to step 7 for V3/V4 Control Stations or go to step 11 for V1/V2 Control Stations. 7. Disable 1000 Mbit/s Full Duplex as follows: For V3 Control Stations, enter: ndd -set /dev/nge0 adv_1000fdx_cap 0 For V4 Control Stations, enter: ndd -set /dev/e1000g0 adv_1000fdx_cap 0 8. Ping the IP address given to you by the hospital network engineer, by entering: ping • If the ping test works, the highest speed supported is 1000 Mbit/s Half Duplex on V3 Control Stations or 100 Mbits/S Full Duplex on V4 Control Stations. • If the ping test fails, the highest supported speed needs determining - go to step 9. 9. Disable 1000 Mbit/s Half Duplex, as follows: For V3 Control Stations, enter: ndd -set /dev/nge0 adv_1000hdx_cap 0 For V4 Control Stations, 1000 Mbit/s Half Duplex is not supported and the Network Interface Card already has 1000 Mbit/s Half Duplex disabled. 10. Ping the IP address given to you by the hospital network engineer, by entering: ping • If the ping test works, the highest speed supported is 100 Mbit/s Full Duplex. • If the ping test fails, the highest supported speed needs determining - go to step 11. Chapter 7 Page no. 656 JC-ELE-A-021.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 11. Disable 100 Mbit/s Full Duplex as follows: For V1/V2 Control Stations, enter: ndd -set /dev/eri adv_100fdx_cap 0 For V3 Control Stations, enter: ndd -set /dev/nge0 adv_100fdx_cap 0 For V4 Control Stations, enter: ndd -set /dev/e1000g0 adv_100fdx_cap 0 12. Ping the IP address given to you by the hospital network engineer, by entering: ping • If the ping test works, the highest speed supported is 100 Mbit/s Half Duplex. • If the ping test fails, the highest supported speed needs determining - go to step 13. 13. Disable 100 Mbit/s Half Duplex as follows: For V1/V2 Control Stations, enter: ndd -set /dev/eri adv_100hdx_cap 0 For V3 Control Stations, enter: ndd -set /dev/nge0 adv_100hdx_cap 0 For V4 Control Stations, enter: ndd -set /dev/e1000g0 adv_100hdx_cap 0 14. Ping the IP address given to you by the hospital network engineer, by entering: ping • If the ping test works, the highest speed supported is 10 Mbit/s Full Duplex. • If the ping test fails, the highest supported is 10 Mbit/s Half Duplex. 15. Enable the Senographe firewall, by entering: /etc/rc2.d/S65ipfboot start 16. Logout as root, by entering: exit 9-2-2 Disabling Auto-negotiation from the Command Line To set the auto negotiation to off on the network interface: 1. Log in as root as follows: a. At the ADS prompt enter: su b. When requested to specify the root password, enter: operator 2. For V1/V2 Control Stations, select the eri0 interface you intend to change, by entering: ndd -set /dev/eri instance 0 3. If the maximum speed supported by the hospital switch port connected to the Control Station is less than that of the eri0/nge0/e1000g0 interface, enter the appropriate commands from Table 1 on page 655 to disable the speeds that are not supported. 4. Set the eri0/nge0/e1000g0 interface auto-negotiation capabilities to no (i.e. 0) as follows: For V1/V2 Control Stations, enter: ndd -set /dev/eri adv_autoneg_cap 0 For V3 Control Stations, enter: ndd -set /dev/nge0 adv_autoneg_cap 0 For V4 Control Stations, enter: ndd -set /dev/e1000g0 adv_autoneg_cap 0 Page no. 657 JC-ELE-A-021.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 9-2-3 Disabling Auto-negotiation at Boot Time via the S93route File To make this setting permanent (done at each boot), you can put these ndd -set command lines in the /etc/rc2.d/S93route file (with or without a route). Each time the system boots the information in the /etc/rc2.d/S93route file is processed automatically. This ensures that the router is automatically declared (if the lines router declaration exist) and the network interface eri0/nge0/e1000g0 is automatically running in auto negotiation=no mode with the maximum speed supported by the hospital switch. To do this, use the following steps: 1. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 2. Log in as root as follows: a. At the ADS prompt enter: su b. When requested to specify the root password, enter: operator 3. Ensure that the /etc/rc2.d/S93route file exists, by entering: touch /etc/rc2.d/S93route 4. Allow the /etc/rc2.d/S93route file to be written to, by entering: chmod ou+w /etc/rc2.d/S93route 5. Exit as root user to return to sdc user, by entering: exit You are returned to the command prompt as sdc user. 6. Open the /etc/rc2.d/S93route file with the textedit command by entering: textedit /etc/rc2.d/S93route The /etc/rc2.d/S93route file appears in an X-Windows based TextEdit application window. Chapter 7 Page no. 658 JC-ELE-A-021.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 7. In the TextEdit application window, add the additional autoneg section after the routing section: For V1/V2 Control Stations type the following lines (separated by carriage returns): #!/bin/sh # Section for routing echo Starting route service route add net # # Section for autoneg echo Setting for no autoneg ndd -set /dev/eri instance 0 If the maximum speed supported by the hospital switch port connected to the Control Station is less than that of the eri0 interface, add appropriate commands from Table 1 on page 655 on each new line to disable the faster speeds that are not supported. For example, if the hospital switch port does not support 100 Mbit/s full duplex, but supports all other speeds add the following line: ndd -set /dev/eri adv_100fdx_cap 0 For example, if the hospital switch port does not support 100 Mbit/s full duplex and 100 Mbit/s half duplex, but supports all other speeds add the following two lines: ndd -set /dev/eri adv_100fdx_cap 0 ndd -set /dev/eri adv_100hdx_cap 0 ndd -set /dev/eri adv_autoneg_cap 0 where is the address to be accessed through the gateway, and is the IP of the gateway (router) indicated by the administrator. Note: Typing the "echo" lines help you to locate any possible faults during boot in case of mistyping the router or auto negotiation information. Note: The example above includes sections for both declaring a router and disabling auto negotiation. Type one or both sections according to your requirements. Page no. 659 JC-ELE-A-021.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration For V3 Control Stations type the following lines (separated by carriage returns): #!/bin/sh # Section for routing echo Starting route service route add net # # Section for autoneg echo Setting for no autoneg If the maximum speed supported by the hospital switch port connected to the Control Station is less than that of the nge0 interface, add appropriate commands from Table 1 on page 655 on each new line to disable the faster speeds that are not supported. If the hospital switch port does not support 1000 Mbit/s full duplex, but supports all other speeds add the following line: ndd -set /dev/nge0 adv_1000fdx_cap 0 If the hospital switch port does not support 1000 Mbit/s full duplex and 1000 Mbit/s half duplex, but supports all other speeds add the following two lines: ndd -set /dev/nge0 adv_1000fdx_cap 0 ndd -set /dev/nge0 adv_1000hdx_cap 0 If the hospital switch port does not support 1000 Mbit/s full duplex, 1000 Mbit/s half duplex and 100 Mbit/s full duplex, but supports all other speeds add the following three lines: ndd -set /dev/nge0 adv_100Ofdx_cap 0 ndd -set /dev/nge0 adv_1000hdx_cap 0 ndd -set /dev/nge0 adv_100fdx_cap 0 If the hospital switch port does not support 1000 Mbit/s full duplex, 1000 Mbit/s half duplex, 100 Mbit/s full duplex and 100 Mbit/s half duplex, but supports all other speeds add the following four lines: ndd -set /dev/nge0 adv_100Ofdx_cap 0 ndd -set /dev/nge0 adv_1000hdx_cap 0 ndd -set /dev/nge0 adv_100fdx_cap 0 ndd -set /dev/nge0 adv_100hdx_cap 0 ndd -set /dev/nge0 adv_autoneg_cap 0 where is the address to be accessed through the gateway, and is the IP of the gateway (router) indicated by the administrator. Note: Typing the "echo" lines help you to locate any possible faults during boot in case of mistyping the router or auto negotiation information. Note: The example above includes sections for both declaring a router and disabling auto negotiation. Type one or both sections according to your requirements. Chapter 7 Page no. 660 JC-ELE-A-021.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration For V4 Control Stations type the following lines (separated by carriage returns): #!/bin/sh # Section for routing echo Starting route service route add net # # Section for autoneg echo Setting for no autoneg If the maximum speed supported by the hospital switch port connected to the Control Station is less than that of the e1000g0 interface, add appropriate commands from Table 1 on page 655 on each new line to disable the faster speeds that are not supported. If the hospital switch port does not support 1000 Mbit/s full duplex, but supports all other speeds add the following line: ndd -set /dev/e1000g0 adv_1000fdx_cap 0 If the hospital switch port does not support 1000 Mbit/s full duplex and 1000 Mbit/s half duplex, but supports all other speeds add the following line ndd -set /dev/e1000g0 adv_1000fdx_cap 0 If the hospital switch port does not support 1000 Mbit/s full duplex, 1000 Mbit/s half duplex and 100 Mbit/s full duplex, but supports all other speeds add the following two lines: ndd -set /dev/e1000g0 adv_100Ofdx_cap 0 ndd -set /dev/e1000g0 adv_100fdx_cap 0 If the hospital switch port does not support 1000 Mbit/s full duplex, 1000 Mbit/s half duplex, 100 Mbit/s full duplex and 100 Mbit/s half duplex, but supports all other speeds add the following three lines: ndd -set /dev/e1000g0 adv_100Ofdx_cap 0 ndd -set /dev/e1000g0 adv_100fdx_cap 0 ndd -set /dev/e1000g0 adv_100hdx_cap 0 ndd -set /dev/e1000g0 adv_autoneg_cap 0 where is the address to be accessed through the gateway, and is the IP of the gateway (router) indicated by the administrator. Note: Typing the "echo" lines help you to locate any possible faults during boot in case of mistyping the router or auto negotiation information. Note: The example above includes sections for both declaring a router and disabling auto negotiation. Type one or both sections according to your requirements. Note: For V4 Control Stations, 1000 Mbit/s Half Duplex is not supported and the Network Interface Card already has 1000 Mbit/s Half Duplex disabled, so there is no need disable this mode within the /etc/rc2.d/S93route file. Page no. 661 JC-ELE-A-021.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A021 - Networking Connection and Configuration 8. Save the /etc/rc2.d/S93route file (File > Save) and double click the TextEdit window to exit the editor. 9. Make the /etc/rc2.d/S93route file non-writable by entering: chmod o-w /etc/rc2.d/S93route 10. Reboot the system for the changes to take effect by entering: reboot button in the top left of the 9-2-4 Testing the network connectivity after disabling auto-negotiation Use the following steps to test whether the there is network connectivity after disabling auto-negotiation: 1. Ask the hospital network engineer for an IP address of a known node on the network that is alive and reachable by a network ping command. 2. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 3. Log in as root as follows: a. At the ADS prompt enter: su b. When requested to specify the root password, enter: operator 4. Disable the Senographe firewall, by entering: /etc/rc2.d/S65ipfboot stop 5. Ping the IP address given to you by the hospital network engineer, by entering: ping • If the ping test works, the auto-negotiation settings you made are correct. • If the ping test fails, double check that you correctly configured the /etc/rc2.d/S93route file, and if necessary work with the hospital network engineer and OLC to resolve the networking issue. 6. Enable the Senographe firewall, by entering: /etc/rc2.d/S65ipfboot start 7. Logout as root, by entering: exit Chapter 7 Page no. 662 JC-ELE-A-021.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A022 - Declare Network Hosts Job Card ELE A022 - Declare Network Hosts 1 Chapter 7 SUPPLIES None 2 APPLICABILITY For network security purposes IP Filters have been implemented from ADS versions 31.27 and above. The final steps in the following procedures that use the IPFreload.sh script are only applicable for ADS versions 31.27. WARNING From ADS versions 31.27 and above a normal ping from a remote host to the ADS computer will result in host unreachable message. This is normal and is due to the IP Filters that have been implemented from ADS versions 31.27 for network security purposes. However, a DICOM ping from a remote host to the ADS computer will work, and it is recommended that you use a DICOM ping from the remote hosts for testing purposes. 3 TOOLS None 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 15 minutes 5 SAFETY PRECAUTIONS No specific safety precautions are applicable. 6 PREREQUISITES Obtain full details of the addresses, names, and characteristics of the hosts to be declared, from the network administrator concerned and/or Remote Host Conformance statement documents. 6-1 Manage Send Settings Determine the host type for each of the hosts you are declaring (i.e. adding or editing) as this affects the setting for their Manage send value. When the value for the manage send function is set to yes, it makes the AWS place the letter “S” in the Browser Series and Image “Status” field when images are sent to the RWS. Host type Setting Review Workstation (RWS) or other workstations Yes – if you will not be sending to a PACS No – if you will be sending to a PACS that supports storage commitment PACS/Archiver that: • supports storage and query–retrieve (Q/R) using a shared AE Title for both storage and Q/R • does not support storage commitment Yes Page no. 663 JC-ELE-A-022.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A022 - Declare Network Hosts Host type Setting PACS/Archiver that: • supports storage and query–retrieve (Q/R) using a shared AE Title for both storage and Q/R (e.g. AGFA) • does support storage commitment Yes PACS/Archiver that: • supports storage and query–retrieve (Q/R) using a different AE Title for both storage and Q/R (e.g. GE PACS) • does support storage commitment Yes PACS/Archiver that: • supports storage and query–retrieve (Q/R) using a different AE Title for both storage and Q/R • does not support storage commitment No 7 PROCEDURE Note: Hosts can be declared before they are physically connected. 7-1 Remote Host Selection Window • From the Browser, click the Tools menu button , then click Network management. The Remote Host Selection window like the following appears (CS V1/V2 version shown). • The Remote Host Selection window displays a list of all currently declared hosts. Click a host name to select it. Click the appropriate button at the bottom of the window to Add or Remove a host. Click Update to apply the changes, or Done button (on V1/V2 Control Stations) / OK (on V3/V4 Control Stations) to close the Remote Host Selection window without applying changes. Chapter 7 Page no. 664 JC-ELE-A-022.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A022 - Declare Network Hosts 7-2 Declaration of a New Host To remove a host from the List of Registered Hosts perform the following steps: 1. Click the Add button in the Remote host selection window. The Remote Host Parameters window like the following appears. Complete the fields in the Remote Host Parameters window according to the information received from the network administrator and the remote host device DICOM 3.0 Conformance Statement. 2. The following fields must be completed for all types of remote host devices (review workstation, NonStorage Commitment capable Archival device, and Storage Commitment capable Archival device): - Host Label: Enter the name you want to give to the icon that will represent the remote host - Host Name: Enter the host name provided by the hospital network administrator. - Application Entity Title: Enter the Application Entity Title (AET). - Network Address: The network address can be local (see Job Card ELE A021 - Networking Connection and Configuration on page 625), or provided by the hospital network administrator. - Network Protocol: Always select DICOM 3.0. - Port Number: Refer to the device DICOM 3.0 Conformance Statement; normal value is 4006. - Manage send must be is set to either No or Yes. The setting you must choose depends on the type of host you are configuring. For more information, see Manage Send Settings on page 663. Page no. 665 JC-ELE-A-022.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A022 - Declare Network Hosts 3. The following field must be completed if the remote host device is a review workstation: - Query Retrieve: Select Patient, Study, or No Provider; (refer to the Review Workstation DICOM 3.0 Conformance Statement). Note: RWS (U60) is not a Q/R provider (it cannot be queried), but some remote stations such as Radworks or AW4.0 (Seno Advantage) are Q/R providers. 4. The following field must be completed if the remote host device is an Archival device: - Storage Commitment: Set to Yes if the Archival device DICOM 3.0 Conformance Statement lists this feature; set to No if the Statement does not list the feature. • If Storage Commitment is set to No; set Message Send to Yes if you want an S to appear in the Report Status column of the Study or Exam list when a study has been sent to the Archival device. • If Storage Commitment is set to Yes; the fields Application Entity Title, Network Address, and Port Number in the lower part of the window are highlighted. You must complete these fields, even if the information is the same as that already entered. This is necessary to allow the possibility of images being sent to one remote host and committed to another. 5. On completion, click the Save button to update and close the window. Note: Network Remote Hosts are not updated in the /etc/inet/hosts file, but are found in the file /export/ home/sdc/Prefs/SdCRHosts. For this reason, it is not possible to use ping, telnet, spray, and similar commands using the hostname. The IP address must be used instead. For example, to ping the MR operator console from the workstation, do not use /usr/sbin/ping MR01_OC0. Instead, use the IP address, e.g., /usr/sbin/ping 192.9.200.1. Though it is not mandatory to declare hosts in the /etc/inet/hosts file when using the SdC NET protocol, it is recommend you to do it in any case. You are returned to the Remote Host Selection window. 6. Click the Done button (on V1/V2 Control Stations) or OK button (on V3/V4 Control Stations) to close the Remote Host Selection window. 7. For Senographe systems using ADS versions 31.27 and above you must reload the Senographe system IP Filters so that the newly declared network host has access through the Senographe system firewall via the DICOM protocol. To do this, perform the following sub-steps: a. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears. b. Execute the IPFreload.sh script, by entering: IPFreload.sh c. When the Password: prompt appears requesting you to enter the root password, enter: operator An End of script message appears. The newly declared network host can now access the Senographe system. 7-2-1 Declaring a DICOM IC (Independent Console) A new protocol has been implemented in order to solve some problems with the IC current software Release 5.5. The problem was that echo, delay, repetition, and inversion times display were being multiplied by 1000. Declare the host as any other Dicom3 host, but select the IC Dicom3.0 protocol. Chapter 7 Page no. 666 JC-ELE-A-022.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A022 - Declare Network Hosts 7-3 Update an Existing Host To update an existing host within the List of Registered Hosts perform the following steps: 1. In the List of registered hosts section within the Remote Host Selection window (CS V1/V2 version shown), click the host name of the host that you intend to update. 2. Click the Update button. The Remote Host Parameters window appears like the following, which contains the existing details of the select host. Append the required fields in the Remote Host Parameters window according to the information Page no. 667 JC-ELE-A-022.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A022 - Declare Network Hosts received from the network administrator and the remote host device DICOM 3.0 Conformance Statement. 3. If necessary, append one or more of the following fields: - Host Label: Enter the name you want to give to the icon that will represent the remote host - Host Name: Enter the host name provided by the hospital network administrator. - Application Entity Title: Enter the Application Entity Title (AET). - Network Address: The network address can be local (see Job Card ELE A021 - Networking Connection and Configuration on page 625), or provided by the hospital network administrator. - Network Protocol: Always select DICOM 3.0. - Port Number: Refer to the device DICOM 3.0 Conformance Statement; normal value is 4006. - Manage send must be is set to either No or Yes. The setting you must choose depends on the type of host you are configuring. For more information, see Manage Send Settings on page 663. 4. If the remote host device is a review workstation, you may need to append the following field: - Query Retrieve: Select Patient, Study, or No Provider; (refer to the Review Workstation DICOM 3.0 Conformance Statement). Note: RWS (U60) is not a Q/R provider (it cannot be queried), but some remote stations such as Radworks or AW4.0 (Seno Advantage) are Q/R providers. 5. If the remote host device is an Archival device, you may need to append one or more of the following fields: - Storage Commitment: Set to Yes if the Archival device DICOM 3.0 Conformance Statement lists this feature; set to No if the Statement does not list the feature. • If Storage Commitment is set to No; set Message Send to Yes if you want an S to appear in the Report Status column of the Study or Exam list when a study has been sent to the Archival device. • If Storage Commitment is set to Yes; the fields Application Entity Title, Network Address, and Port Number in the lower part of the window are highlighted. You must complete these fields, even if the information is the same as that already entered. This is necessary to allow the possibility of images being sent to one remote host and committed to another. 6. On completion, click the Save button to update and close the window. You are returned to the Remote Host Selection window. 7. Click the Done button (on V1/V2 Control Stations) or OK button (on V3/V4 Control Stations) to close the Remote Host Selection window. 8. For Senographe systems using ADS versions 31.27 and above you must reload the Senographe system IP Filters so that the recently updated network host has access through the Senographe system firewall via the DICOM protocol. To do this, perform the following sub-steps: a. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears. b. Execute the IPFreload.sh script, by entering: IPFreload.sh c. When the Password: prompt appears requesting you to enter the root password, enter: operator An End of script message appears. The newly declared network host can now access the Senographe system. Chapter 7 Page no. 668 JC-ELE-A-022.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A022 - Declare Network Hosts 7-4 Remove an Existing Host To remove a host from the List of Registered Hosts perform the following steps: 1. In the List of registered hosts section within the Remote Host Selection window (CS V1/V2 version shown), click the host name of the host that you intend to delete. 2. Click the Remove button in the Remote host selection window. A Remove host dialog box like the following appears. 3. Click the OK button to confirm the removal of the selected host. You are returned to the Remote Host Selection window. 4. Click the Done button (on V1/V2 Control Stations) or OK button (on V3/V4 Control Stations) to close the Remote Host Selection window. 5. For Senographe systems using ADS versions 31.27 and above you must reload the Senographe system IP Filters so that the recently deleted network host no longer has access through the Senographe system firewall via the DICOM protocol. To do this, perform the following sub-steps: a. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears. b. Execute the IPFreload.sh script, by entering: IPFreload.sh c. When the Password: prompt appears requesting you to enter the root password, enter: operator An End of script message appears. The newly deleted network host can no longer access the Senographe system. Page no. 669 JC-ELE-A-022.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A022 - Declare Network Hosts This page is blank. Chapter 7 Page no. 670 JC-ELE-A-022.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A023 - Declare Worklist Hosts Job Card ELE A023 - Declare Worklist Hosts 1 Chapter 7 SUPPLIES None 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 40 minutes 4 SAFETY PRECAUTIONS No specific safety precautions are applicable. 5 PREREQUISITES Obtain full details of the hostname, Application Entity Title, and IP address to be declared from the network administrator or worklist provider concerned. 6 PROCEDURE 1. From the Browser, click the Tools menu button , then click Worklist management. The RIS host selection window like the following appears, which displays a list of all currently registered hosts: 2. Click Add. The RIS Host Parameters window like the following appears. Page no. 671 JC-ELE-A-023.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A023 - Declare Worklist Hosts Note: RIS systems typically utilize the HL7 language. If it does not have integrated DICOM conversion, an HL7 to DICOM interface/broker must be used. This is the sites responsibility. RIS/Worklist icon name RIS hostname Values provided by the RIS IP address worklist server RIS AE Title RIS Port # administrator ! Notice: Worklist server configuration is the responsibility of the RIS administrator. You must give the AWS RIS/Worklist Application Entity Title to the RIS/PACS administrator. The Application Entity Title is WL_XXXX, where XXXX is the Station Name (defined in Job Card ELE A013 - AWS Configuration on page 573) and hostname (defined in Job Card ELE A021 - Networking Connection and Configuration on page 625). Otherwise, you will not be able to update your worklist. Example: If the AWS hostname and Station Name is aws1, the Application Entity Title declared inside the worklist server MUST be WL_aws1. The port number is always 4006. Note: Incorrect declaration of Application Entity Title is the most common issue related to worklist operation. If you witness problems, ensure that the Station Name (defined in Job Card ELE A013 - AWS Configuration on page 573) matches the hostname (defined in Job Card ELE A021 - Networking Connection and Configuration on page 625). 3. Click Save. 4. In the RIS host selection window, click Done (on V1/V2 Control Stations) / OK (on V3/V4 Control Stations). Chapter 7 Page no. 672 JC-ELE-A-023.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A023 - Declare Worklist Hosts 5. In the Browser, click the Worklist button. The Worklist browser window like the following appears: Click to perform RIS Query See next page for settings If Sort by Date&Time does not function correctly work, it is likely that the Solaris operating system language is not English. Only the application language must be the local one. Page no. 673 JC-ELE-A-023.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A023 - Declare Worklist Hosts 6. Click Query. The Query definition window like the following appears. 7. Select All systems in modality from the Which system section. ! Notice: If you do not get a response when "refreshing" using All systems in modality, select All systems. Worklist servers cannot always handle a filtered query such as "All systems in modality". This is since the query places the AWS hostname in the DICOM tag (0040,0001)= "Scheduled Station AE Title". 8. Click Save as default to freeze the selection. 7 • • • • TROUBLESHOOTING Use the "Ping" command to test access to the worklist server. Use the "SendEcho" command to test DICOM association (most worklist servers can support it). Double check AE Title declaration on each side. See log ~sdc/senovision/logfiles/trace.Worklist.log. Chapter 7 Page no. 674 JC-ELE-A-023.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A024 - Declare Performed Procedure Step Hosts Job Card ELE A024 - Declare Performed Procedure Step Hosts 1 Chapter 7 SUPPLIES None 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 40 minutes 4 SAFETY PRECAUTIONS No specific safety precautions are applicable. 5 PREREQUISITES Obtain full details of the remote Performed Procedure Step (PPS) server: Application Entity Title, IP address, and port number to be declared, from the network administrator or PPS server provider concerned. Before PPS is configured and used: • The Declare Network Hosts procedure must have been completed. See Job Card ELE A022 Declare Network Hosts on page 663. • If a PPS server is to be declared for RIS/image archiving, at least one DICOM remote image storage device must be declared on the ADS. This is required so that the DICOM remote image storage device can be associated with the remote PPS server. • If a PPS server is to be declared for CAD image archiving, at least one CAD system must be declared using the service desktop CAD interface from the ADS. This is required so that the CAD system can be associated with the remote PPS server. • The Auto Push feature must be turned on for the relevant network hosts declared in the PPS configuration panel. This is required so that the PPS messages can be sent to the remote servers. Note: For PPS messages to be sent to the remote server associated with a CAD system, the image types pushed to the CAD system must include the raw images. Page no. 675 JC-ELE-A-024.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A024 - Declare Performed Procedure Step Hosts 6 PROCEDURE 1. From the Browser, click the Tools menu button , then click PPS management. The PPS Management selection window like the following appears. • This window is divided into two sections: - The upper section is used to declare the PPS remote servers associated with the archiving system and/or the CAD system. - The lower section is used for management of the PPS retry mechanism if the remote server returns an error. Note: The PPS Server Application Entity Title, IP address, and port number are attached to a specified Image Archiver or CAD system. You must therefore select a system from the drop-down menu before entering PPS configuration data; otherwise the changes are lost. • Determine the number of remote PPS servers (one or two) you have to declare, according to the site workflow. Each PPS instance references the images that have been autopushed to the associated Chapter 7 Page no. 676 JC-ELE-A-024.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A024 - Declare Performed Procedure Step Hosts remote host, based on the currently specified medical application preferences for Auto Push. Use the following table to determine the number of remote PPS servers you have to declare on the system: Auto Push settings for: Image archive CAD PPS setup Raw Not available Declare PPS for RIS/image archive Raw Raw Declare PPS for RIS/image archive Processed Not available Declare PPS for RIS/image archive Processed Raw Declare PPS for RIS/image archive and for CAD Raw+processed Raw Declare PPS for RIS/image archive Note: 1. The Image archive and CAD columns refer to the Auto Push preferences set for the remote image archive and CAD system (if present), that are to be associated with the remote PPS servers. 2. The table does not cover the irrelevant case where processed images are sent to the CAD system, as it would not process them. As a consequence sending processed images to the CAD system does not impact the PPS configuration. • Check the box PPS on RIS/Image archiver and/or the box PPS on CAD, depending on whether you want to configure one or two PPS remote servers. • First select the associated Image Archiver (respectively CAD). Then enter the AET, IP address, and port number of the remote PPS server, using the information provided by the network administrator or PPS remote server provider. • Click the Save button to save the new settings and close the window. Note: It is recommended that you leave the retry management parameters at their default values (three retries, and 30 seconds between retries). These settings can be adjusted later to suit site-specific requirements. 7 TROUBLESHOOTING All PPS communication errors are tracked in the ppslog log file stored in the /export/home/sdc/logfiles directory. If an error is reported in the communication between the ADS and the remote PPS server, the following troubleshooting steps must be taken: • • • • • From the Browser, click the Tools menu button , then click Medical Application Preferences to open the Medical Application Preferences panel. Select the Test Hosts tab. A list of all declared DICOM hosts (storage, worklist, printer, and PPS) appears. Select the appropriate PPS remote server and click the test host button. After a short while a pop-up window appears indicating the DICOM echo status for this particular server. According to the status displayed, check the PPS remote server declaration (AE title, IP address, and port number) If a failure is indicated, check the network declaration of the PPS server and the network configuration of the ADS. Page no. 677 JC-ELE-A-024.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A024 - Declare Performed Procedure Step Hosts This page is blank. Chapter 7 Page no. 678 JC-ELE-A-024.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A028 - Collimation Checks Job Card ELE A028 - Collimation Checks 1 Chapter 7 OBJECTIVE To ensure that: • there is no excessive extension of the X-ray field beyond the edges of the image receptor • the X-ray field aligns with the light field, • the chest wall edge of the compression paddle aligns with the chest wall edge of the image receptor 2 SUPPLIES None 3 • • • • TOOLS One coin (e.g., a nickel, or a 5-Eurocent coin). 4 strips of GAFCHROMIC® XR-M film for each FOV and track tested Aluminium attenuator plate Radiation Protection Plate (used to protect the detector from excessive exposure to X-rays) 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 20 minutes 5 SAFETY PRECAUTIONS The procedures in this Job Card produce X-rays. Ensure that you take appropriate precautions when operating with X-rays (for example, stay behind the radiation screen during an X-ray exposure). 6 PREREQUISITES None Page no. 679 JC-ELE-A-028.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A028 - Collimation Checks 7 PROCEDURE 7-1 Exposures: Mo/Mo and Rh/Rh 7-1-1 X-ray to Light Field Tests 1. Both the Mo and Rh X-ray sources must be tested. Therefore, perform steps 1 through 7 for the large focal spot for both the Mo and the Rh anode tracks.Install the Bucky on the image receptor. 2. Place the Radiation Protection Plate on the surface of the Bucky. Each side of the Radiation Protection Plate must extend about 4 cm beyond each edge of the light field. CAUTION The X-ray doses used in this procedure can saturate the image receptor if the Radiation Protection Plate is not used and not correctly positioned. If the Radiation Protection Plate does not completely cover the field of view, a ghost image may be imposed on the digital image receptor at the edge of the Radiation Protection Plate. Ensure that the entire field of view of the light field is covered by the Radiation Protection Plate. Note: To achive better contrast of the edge of the light field, it is recommended to tape a sheet of white paper to the top of the aluminum attenuator. 3. Verify that the collimator is in the maximum field size setting. 4. Label each of the four XR-M film strips corresponding to the anode track (Mo or Rh), and the field edge (CW - chest wall, Ant - anterior, L - left, R - right) being tested. In the example below, the XR-M film strip is labelled for the Mo anode track, and the chest wall edge. Anode track being tested : Mo or Rh Light field edge being tested : Right (R), Left (L), anterior (Ant), or chest wall (CW) Chapter 7 Page no. 680 JC-ELE-A-028.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A028 - Collimation Checks 5. Turn on the collimator light. Place each of the corresponding XR-M film strips near the center of each light field. ILLUSTRATION 1 - POSITIONING OF XR-M FILM STRIPS X-RM Film B Anterior edge of light field X-RM Film D X-RM Film A X-RM Film C Left edge of light field Right edge of light field Coin Coin attached to chest wall of compression paddle (not shown) Chest wall edge of light field Note: To achieve better contrast of the edge of the light field, it is recommended to place the XR-M film strips with the white side facing the collimator, orange side down. Note: When positioning the XR-M film strips, you must ensure that that positive markers (+1, +2, and +3) are inside the light field as shown above. Page no. 681 JC-ELE-A-028.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A028 - Collimation Checks 6. When placing each of the XR-M film strips, ensure that edge of the light field is aligned with the X marker on the XR-M film strip. There may be a shadow towards the edge of the light field. Ensure the X marker is on the outer edge of the shadow. Inner edge Outer edge Edge of light field Note: When aligning the light field with the X marker on the XR-M film strip, to ensure the light edges are sharply resolved light, it is recommended that you perform this aligment with the room lights off. Note: At the anterior edge of the light field (opposite the chestwall edge), the Bucky cover might obstruct the XR-M, such that it cannot lie flat with the surface of the aluminium attenuator. If there is obstruction from the Bucky, align the "-2" reference line of the XR-M film (instead of the "X" reference line) so that the XR-M film avoids the obstruction and can lie flat with the surface of the aluminium attenuator. Bucky cover can obstruct the XR-M film such that it does not lie flat against the aluminium attenuator. Anterior edge of light field Repositioning the XR-M film to use the "-2" reference instead of the "X" reference can avoid the obstruction from the Bucky cover. Chapter 7 Page no. 682 JC-ELE-A-028.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A028 - Collimation Checks 7. Make a manual exposure using the following parameters: • track/filter combination: either Mo/Mo or Rh/Rh • 30 kVp • 250 mAs 8. Perform the measurements described in section 7-2-1 and section 7-2-2. Then determine if the Action Limits 1 and 2 have passed, as described in section 7-3, Action Limit on page 690. 7-1-2 Compression Paddle Chest Wall Test Both the Mo and Rh X-ray sources must be tested. Perform the steps 1 through 4 for the following paddles: • 19 x 23 paddle • Flexible 19 x 23 paddle (if present with the system) 1. Tape the coin to the underside of the compression paddle as illustrated below. The coin must be as close as possible to the tangent of the inner, vertical surface of the compression paddle at the chest wall edge. Position the coin near the center of the chest wall edge. 2. Place the Radiation Protection Plate on the surface of the Bucky. Each side of the Radiation Protection Plate must extend about 4 cm beyond each edge of the light field. CAUTION The X-ray doses used in this procedure can saturate the image receptor if the Radiation Protection Plate is not used and not correctly positioned. If the Radiation Protection Plate does not completely cover the field of view, a ghost image may be imposed on the digital image receptor at the edge of the Radiation Protection Plate. Ensure that the entire field of view of the light field is covered by the Radiation Protection Plate. 3. Insert the compression paddle and position it approximately 4.2 cm from the Breast Support. 4. Make a manual exposure using the following parameters: • track/filter combination: either Mo/Mo or Rh/Rh • 30 kVp • 250 mAs 5. Perform the measurements described in section 7-2-3 . Then determine if the Action Limit 3 has passed, as described in section 7-3, Action Limit on page 690. Page no. 683 JC-ELE-A-028.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A028 - Collimation Checks 7-2 Measurements 7-2-1 X-ray Field Passing All Four Edges From the RAW digital image on the AWS determine, whether each of the four edges of the X-ray field are outside of the edge of the image receptor. That is, you should not be able to see any of the four edges of the X-ray field in the digital image. • If you can see any of the four edges of the X-ray field in the digital image, there is a problem with the Collimator blade alignment. In this case, you must re-calibrate the Collimator. Once you have re-calibrated the Collimator you must take new exposures before you continue with the measurements described in section 7-2-2 and section 7-2-3. • If you cannot see any of the four edges of the X-ray field in the digital image, the Collimator blades are aligned correctly. You can continue with the measurements described in section 7-2-2 and section 7-2-3. 7-2-2 XR-M Film Measurements From the film and AWS (Acquisition Workstation) RAW digital image, you must make various measurements as described below. Use the Segment tool on the AWS for measurements on the image receptor. Measurements both from the film and the AWS must be scaled to the image receptor plane. You must follow the measurements and calculations described below for each edge of the field (each XR-M film strip A, B, C and D), and complete the following tables. In the tables below, items in bold italics are measured/determined and items in bold are calculated. Mo/Mo Step 1 Yf Step 2 D Zf = D - Yf Step 3 Step 4 Global Scaling Factor (S) = 1.063 x d (in mm) / 10 Zi (S x Zf) Left edge (Film A) Anterior edge (Film B) CW edge (Film C) Right edge (Film D) Rh/Rh Step 1 Yf Step 2 D Zf = D - Yf Step 3 Step 4 Global Scaling Factor (S) = 1.063 x d (in mm) / 10 Zi (S x Zf) Left edge (Film A) Anterior edge (Film B) CW edge (Film C) Right edge (Film D) Chapter 7 Page no. 684 JC-ELE-A-028.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A028 - Collimation Checks In order to complete the tables above and the tables in the Action limits section, perform the following steps for each edge of the field (each XR-M film strip) for both Mo and Rh anode tracks, and if necessary for all field offset positions. 1. Directly from the XR-M film strip, determine the deviation Yf, between the X-ray field and the light field in the plane of the film. Yf can be directly read from the incorprated ruler on the XR-M film strip. In the example illustration below, Yf is 5 mm. Edge of light field (in the plane of the film) Edge of X-ray field (in the plane of the film) Yf = deviation between X-ray field and light field in the plane of the film Note: On the XR-M film strip, the distance between the major "teeth" of the saw tooth pattern is 10 mm, and the tooth-to-tooth distance is 2 mm. Insert the measured value of Yf in the tables above and in the tables for action limit 1 on page 690. 2. Determine the deviation Zf, between the X-ray field from the edge of the detector in the plane of the film. To determine the deviation Zf, proceed as follows: a. From the RAW digital image in the AWS, view the digital image of the XR-M film strip, and determine the location of the detector edge (D) based on the extent of the XR-M film strip imaged. In the example image below, the edge of the detector (D) is 9 mm from the "X" reference marker. Edge of detector Insert the determined value of D in the tables above. b. Knowing the location of the x-ray field edge from step 1 above (i.e. Yf), determine the deviation of the x-ray field edge from the detector edge in the plane of the film (Zf) by using the following equation: Eq. 1 Zf = D - Yf For this example, the edge of the x-ray field is 5 mm from the "X" and the edge of the detector is 9 mm from the "X", and hence, Zf is 4 mm. The relative positions of the edges of the light field, xray field, and detector become more apparent when the x-ray image is scaled and superimposed on the film strip as illustrated in the example below. Page no. 685 JC-ELE-A-028.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A028 - Collimation Checks Edge of X-ray field (in the plane of the film) Edge of detector Edge of light field (in the plane of the film) Yf = deviation between X-ray field and light field in the plane of the film Zf = deviation between X-ray field and detector in the plane of the film Insert the calculated value of Zf in the tables above. 3. Determine the global scaling factor (S) that you need to apply to Zf as follows: a. From the RAW digital image in the AWS, use the Segment tool of the Viewer to measure the distance between two contiguous major reference markers. Measure distance (d) in mm between two contiguous major markers b. Knowing that the distance between two contiguous major markers is 10 mm, calculate the global scaling factor (S) using the following equation: S = 1.063 x d / 10 Eq. 2 Note: Because the reference plane of the Segment tool is 2 cm above the Breast Support surface, a magnification factor 1.063 is applied to value of S as shown in the Eq 2 above. Note: You only need to calculate the global scaling factor (S) once for one of the field edges. You can globally apply the determined global scaling factor (S) to each of the field edges. Insert the determined global scaling factor (S) in the tables above. 4. Finally, determine the deviation of the x-ray field edge from the detector edge in the plane of the image (Zi) by using the following equation: Eq. 3 Zi = S x Z f Insert the calculated value of Zi in the table above and in the tables for action limit 2 on page 691. Chapter 7 Page no. 686 JC-ELE-A-028.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A028 - Collimation Checks 7-2-3 Compression Paddle (Coin) Measurements You must follow the measurements and calculations described below for the coin, and complete the following tables. In the tables below, items in bold italics are measured and items in bold are calculated. Mo/Mo - 19 x 23 paddle Step 1 & 2 Geometric Step 3 Wd Pd Step 4 Step 5 Z’d Zd Case (1.063 x Z’d) Coin (Bottom Edge) (Chest Wall) Mo/Mo - Flexible 19 x 23 paddle Step 1 & 2 Geometric Step 3 Wd Pd Step 4 Step 5 Z’d Zd Case (1.063 x Z’d) Coin (Bottom Edge) (Chest Wall) Rh/Rh - 19 x 23 paddle Step 1 & 2 Geometric Step 3 Wd Pd Step 4 Step 5 Z’d Zd Case (1.063 x Z’d) Coin (Bottom Edge) (Chest Wall) Rh/Rh - Flexible 19 x 23 paddle Step 1 & 2 Geometric Step 3 Wd Pd Case Step 4 Z’d Step 5 Zd (1.063 x Z’d) Coin (Bottom Edge) (Chest Wall) Page no. 687 JC-ELE-A-028.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A028 - Collimation Checks 1. There are two possible geometric cases for the coin. E d g e o f x -ra y fie ld Edge of d e te c to r Edge of x-ray field Edge of detector Z ’d Z’d Pd W d Wd Case 2 Case 1 • Case 1: The outer edge of the coin on the compression paddle goes past the detector edge. Part of the coin is therefore outside of the detector. • Case 2: The outer edge of the coin on the compression paddle does not go past the detector edge. All of the coin is therefore in the detector. 2. Examine the image and determine the geometric case. • If all of the coin is in the detector (case 2), there is a problem with the position of the compression paddle relative to the chest wall edge of the detector. Either change the compression paddle or make adjustments to it, then make another exposure and return to step 1 in this section. • If part of the coin passes past the edge of the detector (case 1), there is no problem with the position of the compression paddle relative to the chest wall edge of the detector. Continue with the measurements in this procedure to determine whether the edge of the compression paddle passes. 3. From the RAW digital image in the AWS, use the Segment tool to measure the following in the plane of the segment tool: • diameter of the coin (Wd) • partial diameter of the coin perpendicular to the edge of the image receptor (Pd) Insert the measured values of Wd and Pd in the table above. 4. From the measured values of Wd and Pd, calculate the deviation (Z’d) between the alignment of the edge of the compression paddle and the edge of the image receptor (in the plane of the segment tool), from the following equation: Z’d = (Wd – Pd) Eq 6 5. Because the reference plane of the Segment tool is 2 cm above the Breast Support surface, use the following equation to scale the calculated deviation (Z’d) in the plane of the segment tool to the plane of the image receptor: Zd = Z’d • M Eq. 7 Chapter 7 Page no. 688 JC-ELE-A-028.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A028 - Collimation Checks where: Zd = the calculation referenced to the image receptor plane. Z’d = the calculation made using the Segment tool. M = 1.063. Insert the calculated value of Zd in the tables above and in the tables for action limit 3 on page 692. Page no. 689 JC-ELE-A-028.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A028 - Collimation Checks 7-3 Action Limit The results from the Mo/Mo and Rh/Rh tests above must adhere to the following three action limits: 1. Congruence of the light field with the X-ray field must be such that the total misalignment (sum of misalignments on opposite sides) is within 2% of the SID. As required by 21 CFR chapter I, Subchapter J, 1020.31(d)(2)(i). Enter measured deviations between the X-ray field and light field on the data form as follows (i.e. Yf for each XR-M film strip determined in step 1 of section 7-2-2) (see illustration 1 on page 681 for film positions): If both | YdA| + |YdD| and | YdB| + |YdC| are less than 13.2 mm then this action limit has passed. If either | YdA| + |YdD| or | YdB| + |YdC| is more than or equal to 13.2 mm then this action limit has failed. Note: If either | YdA| + |YdD| or | YdB| + |YdC| is more than or equal to 10 mm, it is recommended to adjust the position of the Collimator Lamp according to Adjusting a Newly Installed Lamp on page 1388, then re-perform the Collimator Checks. Mo/Mo - The magnitudes of deviations at the left edge and right edge (ignoring + or – signs) are entered on the data form and added together. - Film Edge A Left D Right Yf | Yf A| + |Yf D| Is | Yf A| + |Yf D| less than 13.2 mm? Similarly, the deviations at the anterior and posterior (chest wall) edges are entered (without regard to sign) and the magnitudes added together. Film Edge B Anterior C Posterior (chest wall) Yf | Yf B| + |Yf C| Is | Yf B| + |Yf C| less than 13.2 mm? Rh/Rh - The magnitudes of deviations at the left edge and right edge (ignoring + or – signs) are entered on the data form and added together. - Film Edge A Left D Right Yf | Yf A| + |Yf D| Is | Yf A| + |Yf D| less than 13.2 mm? Similarly, the deviations at the anterior and posterior (chest wall) edges are entered (without regard to sign) and the magnitudes added together. Chapter 7 Film Edge B Anterior C Posterior (chest wall) Yf | Yf B| + |Yf C| Is | Yf B| + |Yf C| less than 13.2 mm? Page no. 690 JC-ELE-A-028.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A028 - Collimation Checks 2. The X-ray field must extend beyond all edges of the active image receptor. The X-ray field must not extend beyond any edge of the image receptor by more than that quoted in Table 1. For each of the exposure configurations below, enter the determined deviations between the edge of the X-ray field and the edge of the image receptor in the plane of the image receptor for each of the four XR-M film strips. That is, the value Zi for each XR-M film strip determined in step 4 of section 72-2. For each of the exposure configurations below, determine whether the action limit for each edge has passed or failed according to the table below (see illustration 1 on page 681 for film positions): TABLE 1 - X-RAY FIELD - IMAGE RECEPTOR ACTION LIMITS Film Edge Action Limit A Left D Right B Anterior • If Zi is below 10 mm, the test has passed, and no further action required. • If Zi is between 10 mm and 13.2 mm, the test may have failed. Consult the physicist regarding the local requirements, and if the test has failed re-calibrate the Collimator according to Job Card CAL A029 - Collimator Format Calibration on page 1683, then reperform the Collimator Checks. • If Zi is above 13.2 mm, the test has failed. Re-calibrate the Collimator according to Job Card CAL A029 - Collimator Format Calibration on page 1683, then re-perform the Collimator Checks. C Posterior (chest wall) • If Zi is between 4 mm and 7 mm, the test has passed, and no further action required. • If Zi is between 0 mm and 4 mm or between 7 mm and 10 mm, the test may have failed. Consult the physicist regarding the local requirements, and if the test has failed re-calibrate the Collimator according to Job Card CAL A029 - Collimator Format Calibration on page 1683, then re-perform the Collimator Checks. • If Zi is above 10 mm, the test has failed. Re-calibrate the Collimator according to Job Card CAL A029 - Collimator Format Calibration on page 1683, then re-perform the Collimator Checks. Mo/Mo Film Edge A Left D Right B Anterior C Posterior (chest wall) Zi Pass / Fail / Comment (see Table 1) Zi Pass / Fail / Comment (see Table 1) Rh/Rh Film Edge A Left D Right B Anterior C Posterior (chest wall) Page no. 691 JC-ELE-A-028.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A028 - Collimation Checks 3. The chest wall edge of the compression paddle must be aligned just beyond the chest wall edge of the image receptor, such that the chest wall edge of the compression paddle does not appear in the mammogram. In addition, the chest wall edge of the compression paddle must not extend beyond the chest wall edge of the image receptor by more than 1% of the SID. Enter the determined deviation between the alignment of the edge of the compression paddle and the edge of the image receptor in the plane of the image receptor for the coin. That is, the value Zd determined in step 5 of section 7-2-3. If the value of Zd for the coin is less than 6.6 mm then this action limit has passed. If the value of Zd for the coin is more than or equal to 6.6 mm then this action limit has failed. Mo/Mo - 19 x 23 paddle Edge Zd Is the value of Zd less than 6.6 mm? Posterior (chest wall) Mo/Mo - Flexible 19 x 23 paddle Edge Zd Is the value of Zd less than 6.6 mm? Posterior (chest wall) Rh/Rh - 19 x 23 paddle Edge Zd Is the value of Zd less than 6.6 mm? Posterior (chest wall) Rh/Rh - Flexible 19 x 23 paddle Edge Zd Is the value of Zd less than 6.6 mm? Posterior (chest wall) If any of these Action Limits are exceeded, the source of the problem must be identified, and corrective actions must be taken. If necessary, call your OLC for help if any of these Action Limits are exceeded. Chapter 7 Page no. 692 JC-ELE-A-028.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A031 - AOP Configuration Job Card ELE A031 - AOP Configuration 1 Chapter 7 SUPPLIES None 2 INTRODUCTION : AOP TABLES DESCRIPTION 2-1 AOP Tables (Classic Tables versus Profile Tables) For each of the three AOP modes, two sets of optimized exposure parameters are available on the Senographe. These are called Profile Tables and Classic Tables. The Profile tables have been created to provide an additional way to manage the trade off between image quality and patient dose by changing some of the selections of exposure parameters for particular breast thickness and composition combinations. Selection of the Classic or Profile tables can be done independently for each of the three AOP modes - Contrast (CNT), Standard (STD), and Dose (DOSE). The changes in exposure parameter selection are expected to affect Contrast to Noise Ratio (CNR) and Average Glandular Dose (AGD). It is important to understand that any improvement in CNR is done at the cost of an increase in AGD and vice versa; a reduction in AGD yields a diminished CNR. • If the site operates in the Contrast mode, and the emphasis is on imaging mid-sized breasts, Classic tables tables may be preferred. If the emphasis is on imaging larger breasts, Classic tables tables may be preferred. • If the site operates in the Standard or Dose mode, and the emphasis is on imaging larger breasts, Profile tables may be preferred. It is the radiologist’s responsibility to make the choice between configuring Profile Tables or Classic Tables. 2-2 AOP Table Identification The AOP tables Classic and Profile are identified in the Senographe system by TAB_A and TAB_B, respectively. 3 TOOLS None 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 15 minutes 5 SAFETY PRECAUTIONS No specific safety precautions are applicable. Page no. 693 JC-ELE-A-031.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A031 - AOP Configuration 6 PREREQUISITES The Application Software versions of the DMR and AWS subsystems must respect the conditions in Table 1. TABLE 1 - SUBSYSTEM REQUIREMENTS Subsystem Version equal or greater than Generator - DMR V1.0.9.CMN ADS Computer - AWS V1/V2 Control Stations V43.0 V3 Control Stations V53.0 V4 Control Stations V54.10 The DMR and AWS Application Software versions are quoted under the Software Release section of the Service Desktop home page (see Launching the Service Desktop on page 120). If these versions are lower than quoted in the paragraph above, you must upgrade them before proceeding (e.g by applying FMI 12075). 7 PROCEDURE 7-1 Goal of the Procedure The Senographe system can be set to use Classic tables (TAB_A) or Profile tables (TAB_B) configuration on the Generator (via the X-ray Console) in each of the AOP modes independently (STD, DOSE and CNT). The ADS Computer must be set with the same configuration as the AOP STD mode configured on the Generator. 7-2 Decide Which Tables You Want to Set 7-2-1 AOP Factory Settings The Senographe system arrives from the factory with Classic tables (TAB_A) set for each of the three AOP modes (DOSE, STD and CNT). TABLE 2 - AOP FACTORY SETTINGS AOP Mode Configured Component Factory AOP Settings STD Generator TAB_A ADS Computer TAB_A DOSE Generator TAB_A CNT Generator TAB_A 7-2-2 Local Recommendations • France : To comply with the "Décision du 30 janvier 2006 fixant les modalités du contrôle de qualité des installations de mammographie numérique", it is suggested to configure the Senographe system with the Profile table (TAB_B) for each of the AOP modes effectively used in clinical operations. • Other European Countries : The Profile tables (TAB_B) allow an easier compatibility with the "European Guidelines for Quality Assurance in Breast Cancer Screening and Diagnosis". • MQSA Countries (e.g. USA) : No specific recommendations. • Other non MQSA and non European Countries : No specific recommendations. Chapter 7 Page no. 694 JC-ELE-A-031.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A031 - AOP Configuration 7-2-3 Review Final AOP Settings 1. Review the Local Recommendations on page 694 above to determine which AOP Configuration to apply. Ensure that the customer obeys any local constraints that may apply to them. 2. Note down the decided configuration in Table 3. TABLE 3 - AOP CONFIGURATION Very first installation Reconfiguration Reconfiguration Reconfiguration 1 2 2 3 Setting Setting Setting Setting Site: Date: AOP Mode Configured Component Generator 7-3 • • STD ADS Computer DOSE Generator CNT Generator Decision Tree At the very first installation: - If you decide to keep the factory settings, go directly to Completion on page 698. - If you decide the AOP settings are different from the factory settings, follow the steps summarized in illustration 1. At a later date after the very first installation: - If you decide to change the current AOP settings, follow the steps summarized in illustration 1. - If the AOP settings were not kept due to performing a DR Job Card or update on the Generator CPU Board or ADS Computer, review the customer’s last known AOP configuration in Table 3 and follow the steps summarized in illustration 1 to restore them. Page no. 695 JC-ELE-A-031.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A031 - AOP Configuration 7-3-1 AOP Configuration Workflow The following flowchart summarizes the workflow of the steps you must take to implement the AOP configuration decided. ILLUSTRATION 1 - WORKFLOW OF STEPS REQUIRED WHEN CHANGING THE AOP CONFIGURATION Generator Configuration (see Setting the AOP Configuration on the Generator on page 697) Configure AOP STD mode Configure AOP DOSE mode Configure AOP CNT mode Checksum and exit Check Generator Configuration (see Checking the Configuration Set on the Generator on page 697) Check AOP STD mode Check AOP DOSE mode Check AOP CNT mode Exit ADS Computer Configuration (see Setting the AOP Configuration on the ADS Computer on page 697) Configure AOP STD mode Exit Check ADS Computer Configuration (see Setting the AOP Configuration on the ADS Computer on page 697) Check AOP STD mode Exit Chapter 7 Page no. 696 JC-ELE-A-031.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A031 - AOP Configuration 7-4 Setting and Checking the AOP Configuration on the Generator 7-4-1 Setting the AOP Configuration on the Generator Use the following steps to set the AOP configuration on the Generator. 1. Select SETUP/GENE/INSTAL/GENE/AOP/APOLLO/TYPE on the X-ray Console. 2. From the SETUP/GENE/INSTAL/GENE/AOP/APOLLO/TYPE menu, select the DOSE mode. 3. Select TAB_A to set the DOSE mode to use Classic table (TAB_A), or TAB_B to set the DOSE mode to use Profile table (TAB_B). 4. From the SETUP/GENE/INSTAL/GENE/AOP/APOLLO/TYPE menu, select the STD mode. 5. Select TAB_A to set the STD mode to use Classic table (TAB_A), or TAB_B to set the STD mode to use Profile table (TAB_B). 6. From the SETUP/GENE/INSTAL/GENE/AOP/APOLLO/TYPE menu, select the CNT mode. 7. Select TAB_A to set the CNT mode to use Classic table (TAB_A), or TAB_B to set the CNT mode to use Profile table (TAB_B). 8. Press the SETUP button five times on the X-ray Console to reach the checksum menu. 9. Select CKSUM/CKSUM to perform a checksum. 10. Keep pressing the SETUP button until you exit the configuration menu on the X-ray Console. 7-4-2 Checking the Configuration Set on the Generator Use the following steps to check the AOP Configuration that is set according to your requirements for each mode on the Generator. 1. Select SETUP/GENE/INSTAL/GENE/AOP/APOLLO/TYPE on the X-ray Console. 2. From the SETUP/GENE/INSTAL/GENE/AOP/APOLLO/TYPE menu, select the mode that you want to check (DOSE , STD, CNT). 3. Check the value displayed to the right selected mode. • If this value is TAB_A, the selected mode is configured with the Classic table. • If this value is TAB_B, the selected mode is configured with Profile table. 4. Keep pressing the SETUP button until you exit the configuration menu on the X-ray Console. 7-5 Setting and Checking the AOP Configuration on the ADS Computer The AOP STD mode on the ADS Computer must be set to match the AOP STD mode on the Generator. 7-5-1 Setting the AOP Configuration on the ADS Computer Use the following steps to set the AOP configuration on the ADS Computer. 1. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 2. Log in as root as follows: a. At the ADS prompt enter: su b. When requested to specify the root password, enter: operator 3. Change to the ~sdc/senovision/scripts directory, by entering: cd ~sdc/senovision/scripts Page no. 697 JC-ELE-A-031.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A031 - AOP Configuration 4. Run the setaop.sh script with the appropriate option to set AOP configuration on the ADS Computer to correspond with the AOP STD mode set on the Generator. • If the Classic table (TAB_A) is configured for the AOP STD mode on the Generator, configure the ADS Computer with Classic table (TAB_A) configuration for the AOP STD mode by entering: setaop.sh AOP_STD_A • If the Profile table (TAB_B) is configured for the AOP STD mode on the Generator, configure the ADS Computer with Profile table (TAB_B) configuration for the AOP STD mode by entering: setaop.sh AOP_STD_B The setaop.sh script displays the current configuration, and prompts you to confirm whether you want to change this setting. 5. When prompted to change the configuration, confirm the change by entering: y 6. Once the setaop.sh script finishes, log out at root user by entering: exit 7. Close the command window, by entering: exit 7-5-2 Checking the AOP Configuration is Set on the ADS Computer Use the following steps to check that the AOP configuration that is set on the ADS Computer. 1. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 2. Change to the ~sdc/senovision/scripts directory, by entering: cd ~sdc/senovision/scripts 3. Run the setaop.sh script to query the current AOP configuration, by entering: setaop.sh The setaop.sh script displays the current configuration. Check that the current configuration corresponds to your desired AOP STD mode: • If this value is AOP STD TAB_A, STD mode is configured with the Classic table (TAB_A). • If this value is AOP STD TAB_B, STD mode is configured with Profile table (TAB_B). 4. Close the command window, by entering: exit 8 COMPLETION Note down the configuration that you set during installation in within AOP Configuration on Generator and AWS Computer on page 799 in Form LBK A001 - System Configuration Form. Chapter 7 Page no. 698 JC-ELE-A-031.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A032 – IQ Tools Flat Field Test Job Card ELE A032 – IQ Tools Flat Field Test 1 Chapter 7 SUPPLIES None 2 APPLICABILITY This Job Card applies to the core product. If the system has the CESM option, perform the CESM version of this Job Card located in the CESM IM/SIP instead. 3 • • TOOLS Flat Field Phantom ACR standard phantom (16 cells Nuclear Associates 18-220 or RMI-156) 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 30 minutes. 5 SAFETY PRECAUTIONS The procedures in this Job Card produce X-rays. Ensure that you take appropriate precautions when operating with X-rays (for example, stay behind the radiation screen during an X-ray exposure). 6 PREREQUISITES The system must have been correctly installed and calibrated. 7 FLATFIELD TESTS 7-1 Objective The flatfield test measures the ability of the detector to reproduce the image of a flat and homogeneous phantom. The ideal response of the detector is a uniform image with no large or small defects, with no pixel having a signal much higher or much weaker than its neighbors, and with a uniform signal-to-noise ratio. The quantities to look for are thus: - Brightness Non uniformity: the magnitude of low frequency structures (large shapes). - High frequency modulation: the magnitude of high frequency structures (small defects). - Number and density of bad pixels: the number of pixels having signals significantly different from those of their neighbors (new bad pixels appeared since the latest bad pixel calibration), and the density of these bad pixels. - Signal-to-noise ratio (SNR) Non uniformity: the variation of signal-to-noise ratio over the image. A test failure indicates incorrect test conditions (phantom position, cleanliness), or an artifact causing inconsistency between the current image and the associated gain map. Such an inconsistency means that either the gain calibration needs to be updated, or the current image contains a defect which must be identified (see section 9). Possible sources of artifacts include the tube output window, the mirror, the Molybdenum filter, the collimator blades, and the detector. Page no. 699 JC-ELE-A-032.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A032 – IQ Tools Flat Field Test 7-2 Method The flatfield image is analyzed by measuring the mean signal level, the noise, and the number of new bad pixMeasurements made i els in a moving analysis box (a 20 mm x 20 mm region a moving analysis box of interest scanning the flatfield image with a 10 mm overlap). The total number of new bad pixels is summed over the whole image. The following checks are performed: - Brightness Non uniformity (BNU): compute maximum deviation of the mean signals measured in each ROI. - High frequency modulation (HFM): measure the minimum signal–to–noise from all ROIs - New bad pixels: detect and count all bad pixels in the whole image - New bad ROIs: count number of regions of interest containing more than 2 bad pixels - Signal–to–noise ratio (SNR) Non uniformity: compute maximum deviation of the SNR measured in each ROI. 8 PROCEDURE 1. From the Browser, click on the QAP button, then select Flat Field Test. 2. Follow the on-screen instructions. You are asked to: a. Remove the bucky and the compression paddle, and to place the flatfield phantom on the image receptor. b. Verify using the light beam that the collimator is in full field of view. c. Verify that the tube arm angle is 0 degrees. d. Make two exposures using the parameters set automatically (Large focal spot; Mo/Mo; 26 kV; 200 mAs). 3. Use the middle-button mouse function to adjust the image for optimum viewing conditions. Suggested starting values are WW = 3000 and WL = 4500. 4. The system calculates and displays test results in a format similar to that shown below. The LSL and USL columns show the minimum acceptable values (Lower Specification Limit) and the maximum acceptable values (Upper Specification Limit) for each test. Test LSL USL Brightness Non Uniformity n/a 10.00 High Frequency Modulation n/a 0.80 Bad Pixel n/a 100.0 Bad ROI n/a 0.00 SNR n/a 40.00 Chapter 7 Measurement Pass/Fail Page no. 700 JC-ELE-A-032.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A032 – IQ Tools Flat Field Test 9 CORRECTIVE ACTIONS IN CASE OF FAILURE 9-1 Brightness Non Uniformity test fails Typical causes are: 1. The flatfield phantom does not cover the full FOV; Brightness non-uniformity: check the position of the flatfield phantom. The flatSignificant signal field phantom must exceed the detector field of view variation detected in the image in every direction. 2. A collimator blade is within the FOV; make an acquisition in the Medical application in the same conditions as the flatfield test (flatfield phantom, MoMo, 26 kV, 200 mAs) and verify in the raw image that the X-ray beam field covers the detector field of view by adjusting the contrast such that window width is less than 200. If collimator blades are visible at the borders, check tube tilt, centering and collimator format calibrations. If necessary redo these calibrations. 3. The gain map is no longer valid; calibrate gain in the MoMo/no grid configuration, move the phantom slightly and run the test again. 9-2 High Frequency Modulation test fails Typical causes are: 1. The detector temperature is not stabilized; check that the system has not been powered on too recently. 2. The gain map is no longer valid; calibrate gain in the MoMo/no grid configuration, and run the test again. Page no. 701 JC-ELE-A-032.fm High frequency modulation: High noise detected within a ROI Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A032 – IQ Tools Flat Field Test 9-3 Bad Pixels or Bad ROI test fails WARNING One Defect category FAIL means that the detector is above the GE Bad Pixel specifications. The root cause of the failure must be found before the customer can use the system for clinical use. If the customer uses a detector having more Bad Pixels than allowed there is a risk to loose information in the clinical images. If Bad pixel or Bad ROI tests fail, do no change the Flat Field Phantom before performing the section 93-1, section 9-3-2 and section 9-3-3 of this troubleshooting guide. 9-3-1 Check if Dust is present on the image receptor Ensure the image receptor is completely clean and run the test again. 9-3-2 Dust is present on the light beam alignment mirror or on the Mo filter Clean the mirror and Mo filter without direct contact according to the directions in Job Card PM A255 Collimator and Tube Head Cleaning on page 1787. Then run the flat field test again. In case dust is found, it is recommended to install the Dust reduction kit (P/N 5394527) to reduce this problem occurrence. 9-3-3 Check if the flat field phantom is the root cause of the issue 1. Clean the Flat Field Phantom to avoid any dust on it, use water if required but no chemical product. 2. Run the Flat Field Test, locate the bad ROIs or bad pixels, adjust the viewing contrast to make the spot visible. 3. Move the Flat Field Phantom slightly, run the Flat Field Test again and note whether the bad ROIs or pixels have moved. Use the mouse middle button to adjust contrast and brightness such that window width WW is less than 200. If necessary, take the images in the Medical Application and use the AWS display tools. 4. Check the position of the detected bad pixel, and determine your next step: • If the bad pixels are at the same position the Flat Field Phantom is not responsible for the test failure and does not need changing. Continue the troubleshooting in section 9-3-4. • If the bad pixel followed the Flat Field Phantom positioning, the phantom is the cause of the test failure. Ensure that this phantom is free from dust (pay specific attention to the part that covers the bad pixel area in the image), you may repeat the test again after cleaning. If bad pixels are still at the same position, you will need to change the flat field phantom. Change the Flat Field Phantom and redo the test without performing any calibration. Chapter 7 Page no. 702 JC-ELE-A-032.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A032 – IQ Tools Flat Field Test 9-3-4 The collimator is visible in the field of view Run the flatfield test, locate the bad ROIs or bad pixels. If there are bad pixels or bad ROIS, check tube tilt, centering and collimator format calibrations. If necessary redo these calibrations. Collimator visible in field of view 9-3-5 Detector response is unequal at some rows, columns, or groups of pixels 1. Check that there is no visible group of defective of pixels (a group of defective pixels = 2 pixels or more which are significantly darker or brighter than the background). Use the mouse middle button to adjust contrast and brightness such that window width WW is less than 200. If necessary, take an image in the Medical Application and use the AWS display tools. 2. If there is at least one group: check that the mirror is clean and free from dust (if not, clean it up) and redo the gain calibration in the configuration of the test which is failing. Move slightly the Flat Field phantom between each X-ray exposure 3. Redo the Flat Field test in the same configuration 4. If it is not passing, run the bad pixel calibration. Move the Flat Field phantom between each X-ray exposures. 5. Redo the Flat Field test in the same configuration. 6. If it is still not passing contact OLC. 9-4 Signal–to–Noise Ratio Non uniformity fails Typical causes are: 1. The X-ray beam is badly centered; carry out the Job Card CAL A027 - Tube Tilt Calibration on page 1681 and Job Card CAL A029 - Collimator Format Calibration on page 1683. 2. The detector sensitivity is not uniform; locate in the graphical window the area having a poor SNR (low mean signal or high standard deviation). Calibrate gain in the MoMo/no grid configuration, and run the test again. If the SNR Non uniformity result is still above the Upper Specification Limit, call your OLC for a possible detector replacement. Page no. 703 JC-ELE-A-032.fm Significant signal-to-noise variation detected in the image Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A032 – IQ Tools Flat Field Test 9-5 Final checks ! Notice: If a new gain calibration was done, you are recommended to recalibrate all other gain configurations. After investigating and correcting the suggested causes of error, repeat the test. If the test still fails, call your OLC. Chapter 7 Page no. 704 JC-ELE-A-032.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A037 - Image Acquisition and ACR Score Job Card ELE A037 - Image Acquisition and ACR Score 1 Chapter 7 SUPPLIES None 2 TOOLS ACR standard phantom (16 cells Nuclear Associates 18-220 or RMI-156) 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 8 minutes 4 SAFETY PRECAUTIONS. The procedures in this Job Card produce X-rays. Ensure that you take appropriate precautions when operating with X-rays (for example, stay behind the radiation screen during an X-ray exposure). 5 PREREQUISITES The system must have been correctly installed and calibrated. 6 TEST DESCRIPTION 6-1 ACR Phantom The phantom used in this procedure is a block of acrylic containing 16 cells. Each cell simulates an anatomical structure which can be found in breast tissue. The acrylic gives attenuation equivalent to a breast of average density compressed to a thickness of 45 mm. Starting from the top left-hand corner, as shown in the illustration, the cells are of three types: 1. Fibers. Six cells represent fibrous calcifications; they contain fibers with sections from 1.56 mm to 0.40 mm. 2. Specks (Calcifications). Five cells represent groups of specks or microcalcifications, with sizes from 0.54 mm to 0.16 mm. 3. Masses. Five cells represent tumors or masses, with sizes from 2 mm to 0.25 mm; each has a different attenuation. 6-2 ACR Score The ACR Score check program obtains and displays an image of the phantom. After suitable adjustment of the viewing parameters, the user notes the visibility of the object in each cell, using a 3-point scale of 1, 0.5, or 0. For each cell, score: - 1 If the object (fiber, mass, or group of six specks) is completely visible. - 0.5 If the object is partially visible, according to the following guidelines; Page no. 705 JC-ELE-A-037.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A037 - Image Acquisition and ACR Score - 7 Fibers; More than half of the fiber is visible. Masses; The mass does not appear circular, but is visible. Specks; At least two specks are visible For all other cases 0 PROCEDURE 1. Install the Bucky, with compression paddle. 2. Place the ACR phantom on the Bucky, against the chest wall side and laterally centered. 3. Lightly compress the phantom with the compression paddle. 4. Check that the collimator is in full FOV and that the tube arm angle is 0 degrees. 5. Enter the Phantom IQ test. From the Browser, click the QAP button . 6. The system applies suitable parameters (Rh/Rh, 29 kV, 56 mAs, LF). Make an exposure and display the image. 7. The image appears with standard parameters which may need adjusting for your system. Press the right mouse button to display a 2-item menu which allows you to select the middle button function. Use it either to control brightness and contrast (window length (WL) changes with vertical movement and window width (WW) changes with horizontal movement) or to obtain the magnifying glass function. As a rough guide, it is suggested that the contrast is adjusted to obtain an on-screen displayed value for WW of less than 200 for good viewing. 8. Obtain the best viewing conditions for an accurate assessment of the score. If necessary, complete the test and repeat it with the phantom in a better position, and observe the 16 cells in the phantom image. Note the ACR score (1, 0.5, or 0, as described in the Test Description above) for each cell, and total the scores for each type of cell (fibers, masses, speck groups). 9. A group of three on-screen sliders are displayed at the top right of the screen. For each type of cell, move the on-screen slider (with the cursor on the slider, press, and hold the mouse button while moving the mouse) until the correct score appears. Then click OK to enter the score into the system. 10. The results of the test are displayed in a format like that shown below. The LSL and USL columns show the minimum acceptable score (Lower Specification Limit) and the maximum score (Upper Specification Limit) for each item. The figures given here in the Measurement and Status columns are for example only. Test Measurement LSL USL Status Masses 4.00 3.00 5.00 Passed Speck groups 2.50 3.00 5.00 Failed Fibers 5.00 4.00 6.00 Passed Score 11.50 11.00 16.00 Passed 11. The test is successful if the total score is 11 or more, with scores for masses of at least 3, for speck groups of at least 3, and for fibers of at least 4. In the example shown the total score is 11.5, but the test fails because the speck group score is less than 3. 12. If the test fails, repeat the flatfield test and then try again. If the flatfield test passes successfully but the ACR Score test fails, the cause must be identified and corrected before further patient examinations are made. Chapter 7 Page no. 706 JC-ELE-A-037.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A038 - AOP Mode and SNR Check Job Card ELE A038 - AOP Mode and SNR Check 1 Chapter 7 SUPPLIES None 2 TOOLS Set of acrylic plates ! Notice: To avoid false results, the plates must be clean and free from scratches. 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 15 minutes 4 SAFETY PRECAUTIONS. The procedures in this Job Card produce X-rays. Ensure that you take appropriate precautions when operating with X-rays (for example, stay behind the radiation screen during an X-ray exposure). 5 PREREQUISITES To allow temperature of the detector to stabilize, the system must be powered on for at least 10 minutes before performing any measurements related to detector image quality. If any test is not passed after allowing a 10-minute warm-up period, see the Guidance section reference in section 7 Action Limit. 6 PROCEDURE 6-1 Objective The test is designed to check the following aspects of system operation: - Correct choice of parameters in AOP (Automatic Optimization of Parameters) mode. - Correct level of SNR (Signal–to–Noise Ratio) in the image. This check is also described in the section AOP Mode and SNR Check of the Senographe DS QC Manual. 6-2 Method 1. From the Browser, click the QAP button . A list of tests appears. Select the AOP and SNR Check test. 2. Install the compression paddle most commonly used by the Operator. 3. The following procedure must be carried out for each of the three thicknesses of acrylic in the field of view (that is 25 mm, 50 mm and 60 mm). a. Place the acrylic plates so that they lie flat on the breast support surface of the Bucky, and stack them to make the required thickness. b. Position the plates with the largest side aligned with the chest wall edge of the Bucky. c. Center the plates left-to-right. d. Apply a compression force of 5 daN to the plates. Page no. 707 JC-ELE-A-038.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A038 - AOP Mode and SNR Check Note: To easily apply a compression force of 5 daN with precision, you can use the MEDICAL/COMP/ FORCE menu on the X-ray Console to set the maximum compression force limit to 5 daN. If you do this, remember to return the maximum compression force limit to the clinically used value following completion of the test. e. AOP STD mode is selected automatically. f. Take an exposure. g. After the image has been captured, the results are displayed (exposure parameters used as well as SNR). h. Record these results in Table 1 below. After performing sub-steps a to h, repeat sub-steps a to h for the 50 mm and 60 mm thicknesses. TABLE 1 - AOP MODE AND SNR CHECK RESULTS Thickness kVp Track Filter mAs SNR 25 mm 50 mm 60 mm 7 ACTION LIMIT If at the end of the results, AOP B is displayed, the AOP Mode test is successful if the exposure parameters are in accord with the values specified in the following table: Acrylic Thickness Exposure Parameters (mm) For AOP STD mode only Track/filter mAs kV 25 Mo/Mo 20 – 60 26 50 Rh/Rh 40 - 90 29 60 Rh/Rh 60 - 120 30 or 31 If at the end of the results, AOP B is not displayed, the AOP Mode test is successful if the exposure parameters are in accord with the values specified in the following table: AWS Version (*) Acrylic Thickness Exposure Parameters (mm) For AOP STD mode only Track/filter mAs kV All 25 Mo/Mo 20 – 60 26 All 50 Rh/Rh 40 - 90 29 V32.10 and lower 60 Rh/Rh 45 - 95 31 V43.0 and higher 60 Rh/Rh 45 - 95 30 or 31 (*) The AWS Application Software version is displayed in the title bar of the Browser, in the form AWS-V:X.Y. For example, AWS-V:32.10 or AWS-V:43.0. The value of SNR must exceed 50. Chapter 7 Page no. 708 JC-ELE-A-038.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A038 - AOP Mode and SNR Check Note: For AWS AWS Application Software equal to V43.0 or higher: For the 60 mm acrylic thickness, either 30 kVp or 31 kVp can be selected by the AOP algorithm. This is normal operation. It is also normal operation that the mAs used with 30 kVp is greater than the value used with 31 kVp. It is only necessary that the mAs remain within the range given in the previous table. If the system fails the test and you have a Gantry CPU Board running NSC 1.2.13 or above, apply Job Card CAL A049 - Compression Paddle Offset Calibration on page 1711 on the compression paddle that you used to perform the test. Setting a compression paddle offset may resolve the issue of the failing test. If the system continues to fail the test after declaring a paddle offset, the source of the problem must be identified, and corrective action taken, before any further mammographic images are acquired. Page no. 709 JC-ELE-A-038.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A038 - AOP Mode and SNR Check This page is blank. Chapter 7 Page no. 710 JC-ELE-A-038.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A039 - Compliance with Germany for Detector Dose Job Card ELE A039 - Compliance with Germany for Detector Dose Chapter 7 1 SUPPLIES None 2 TOOLS Set of acrylic plates (stack 4 of the 10 mm plates and the 5 mm plate to yield a thickness of 45 mm) 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 10 minutes 4 SAFETY PRECAUTIONS The procedures in this Job Card produce X-rays. Ensure that you take appropriate precautions when operating with X-rays (for example, stay behind the radiation screen during an X-ray exposure). 5 PREREQUISITES Activate the display of exposure parameters: select SETUP/GENE/INSTAL/GENE/CONFIG/DISP/YES on the X-ray Console. Deactivate the auto decompression: select MEDICAL/DECOMP/DECOMP/NO on the X-ray Console. 6 PROCEDURE 6-1 Objective This procedure ensures that the Senographe system complies with Detector Dose German regulations. 6-2 First Exposure 1. Make one exposure for each AOP mode, with 45 mm thickness of acrylic on the Bucky compressed at 4 daN. To yield an acrylic thickness of 45 mm, stack 4 of the 10 mm plates and the 5 mm plate. 2. Note the displayed exposure parameters in the following table: TABLE 1 AOP mode Spectrum (Target/ Filter, kVp) CNT RhRh29 STD RhRh29 Dose RhRh29 mAs Radiological thickness, cm Composition: % • The radiological thickness must be in the range 4.40 cm to 4.60 cm. If not: - Repeat the AOP calibration (Job Card CAL A051 - AOP Calibration on page 1723). - Repeat steps 1 and 2. • The composition must be in the range 45% to 55%. If not: - Repeat the compression thickness calibration (Job Card CAL A050 - Compression Thickness Calibration on page 1721). - Repeat steps 1 and 2. Increasing mechanical thickness causes a decrease of composition. Page no. 711 JC-ELE-A-039.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A039 - Compliance with Germany for Detector Dose 6-3 Calculation of New Parameter A Adjust the AOP calibration: 1. On the X-ray Console, go to the menu GENE/INSTAL/GENE/AOP/APOLLO/CALIB/. 2. Select the configuration GridLF/PARAM/LFRhRh. Note the value of parameter A (Aold): Aold 3. Calculate the new AOP parameter Anew: 4. Anew = 4.66 - (STD Radiological thickness from Table 1) + Aold. 5. Change the parameter Aold by A new in X-ray Console menu. Anew 6. Perform a checksum (SETUP/GENE/INSTAL/CKSUM/CKSUM). 6-4 Exposure with New Parameter A 1. Repeat one exposure for each AOP mode with 4.5 cm acrylic thickness on the Bucky and compression of 4 daN. 2. Note the exposure parameters in the following table: TABLE 2 AOP mode Spectrum (Target/ Filter, kVp) CNT RhRh29 STD RhRh29 Dose RhRh29 mAs Radiological thickness, cm Composition, % The radiological thickness must be in the range 4.65 to 4.67. If not, check your calculation of the parameter Anew. The composition must be in the range 40% to 60%. If not, adjust the mechanical thickness by applying a different compression force, which must increase the mechanical thickness. The increase of mechanical thickness causes a decrease of composition. When the composition is in the range 40% to 60%, repeat steps 1 and 2. Chapter 7 Page no. 712 JC-ELE-A-039.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A039 - Compliance with Germany for Detector Dose 6-5 Detector Dose Measurement Detector Dose measurements according to DIN 6868-152. 1. Remove the Bucky and install the dose measure support tool. 2. Place the Bucky and the 45 mm acrylic plate on the top of support tool. 3. Install the 6M Dose probe in the lower position. 4. Perform exposures in manual mode with parameters as close as possible to the AOP exposure parameter (Table 2) and measure the detector dose (1mR=8,76*10-6 µGy). TABLE 3 AOP mode Spectrum (Target/Filter, kVp) CNT RhRh29 STD RhRh29 Dose RhRh29 mAs Detector Dose, measured by dosimeter, µGy The measured detector dose has to be less than 75 µGy for STD and Dose mode. 6-6 Contrast Mode Deactivate Note: Using the STD mode should satisfy most needs. However, if a higher priority is given to the dose delivered to the patient, the DOSE mode may be selected instead. If a higher priority is given to the contrast to noise ratio in images, the CNT mode may be selected. It is important to understand that any improvement in contrast to noise ratio is done at the cost of an increase in glandular dose and vice versa; a decrease in glandular dose will yield a reduction in contrast to noise ratio. For more information on evaluating which priority to select, consult with your interpreting physician or radiologist. In case of site specific requirements, the access to CNT mode can be restricted as described in To Deactivate the Contrast Mode on page 789. 7 POST-REQUISITES On the X-ray Console, select MEDICAL/DECOMP/DECOMP/YES to activate the auto decompression feature. Page no. 713 JC-ELE-A-039.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A039 - Compliance with Germany for Detector Dose This page is blank. Chapter 7 Page no. 714 JC-ELE-A-039.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A042 - Bar Code Scanner (Option) Job Card ELE A042 - Bar Code Scanner (Option) 1 Chapter 7 SUPPLIES Bar Code Scanner 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 17 minutes 4 SAFETY PRECAUTIONS None 5 PRE-REQUISITES The system must have been correctly installed and normal application software must be operational. 6 PROCEDURE 6-1 Introduction The bar code scanner is a fast and accurate tool for scanning bar code symbols in AWS applications. It allows patient information to be entered rapidly and accurately. Available with an 80 mm CCD scanning window and an integrated keyboard decoder, the scanner captures an entire bar code symbol instantly. The integrated decoder then transmits the data to the AWS workstation as if the data was entered from the AWS keyboard. Supported bar code types are: - Code 3 of 9 (standard & full-ASCII) - EAN 13 - Code 128 Page no. 715 JC-ELE-A-042.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A042 - Bar Code Scanner (Option) 6-2 Identify and if Necessary Pre-Configure The Bar Code Scanner Two models of the bar code scanner exist, as follows: • 3800LX-14 - has a coiled USB cable • 3800G - has an uncoiled (straight) USB cable The model number (3800LX-14 or 3800G) is located underneath the head of the bar code scanner. • If the model number of the bar code scanner is 3800LX-14, no pre-configuration is required and you can proceed directly to Connect the Bar Code Scanner on page 720. • If the model number of the bar code scanner is 3800G, the following pre-configuration steps are required before you can proceed to Connect the Bar Code Scanner on page 720. 1. Ensure your laptop PC is powered off, and connect the bar code scanner with model number 3800G to a USB connector on your laptop PC. Note: Connection or disconnection of the bar code scanner USB cable while the laptop PC is powered on on can cause damage to the bar code reader and/or the laptop PC. 2. Power on your laptop PC. 3. Hold the scanner handle horizontally directly over the bar code printed below. 4. Press the scanner trigger located below the scanner handle; the scanner red LED beam lights. The scanner has successfully scanned the symbol if: - You hear a beep. - The LED beam turns off. The bar code scanner is now set back to its factory defaults. 5. Hold the scanner handle horizontally directly over the bar code printed below. 6. Press the scanner trigger located below the scanner handle; the scanner red LED beam lights. The scanner has successfully scanned the symbol if: - You hear a beep. - The LED beam turns off. The bar code scanner is now to full ASCII on mode. 7. Power down your laptop PC. 8. Disconnect the bar code scanner from your laptop PC. Note: If you want to implement a different code set (for example ISBT 128) or change the bar code message length, refer to the bar code scanner documentation. Chapter 7 Page no. 716 JC-ELE-A-042.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A042 - Bar Code Scanner (Option) 6-3 Configuration for V1/V2 Control Stations Refer to the diagram below when connecting the bar code scanner to V1/V2 Control Stations: Base of SB150 ADS SB150 station Top of SB150 Respect the connections shown here ; incorrect connection may prevent boot Free Trackball or Mouse Bar Code Scanner Keyboard USB connectors Keyboard Trackball or mouse Bar Code Scanner Mouse or Trackball Keyboard Bar Code Scanner Empty Page no. 717 JC-ELE-A-042.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A042 - Bar Code Scanner (Option) 6-4 Configuration for V3 Control Stations Refer to the diagram below when connecting the bar code scanner to V3 Control Stations: ADS U20 station Base of U20 USB connectors Keyboard Trackball or mouse Top of U20 Respect the connections shown here; incorrect connection may prevent boot Bar Code Scanner Trackball or Mouse Free Keyboard Bar Code Scanner Mouse or Trackball Keyboard Bar Code Empty Scanner Chapter 7 Page no. 718 JC-ELE-A-042.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A042 - Bar Code Scanner (Option) 6-5 Configuration for V4 Control Stations Refer to the diagram below when connecting the bar code scanner to V4 Control Stations: Base of Z400 ADS Z400 station Top of Z400 Respect the connections shown here; incorrect connection may prevent boot USB connectors Bar Code Scanner Trackball or Mouse Free Keyboard Free Free Keyboard Trackball or mouse Bar Code Scanner Mouse Keyboard or Trackball Empty Bar Code Empty Scanner Page no. 719 JC-ELE-A-042.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A042 - Bar Code Scanner (Option) 6-6 Connect the Bar Code Scanner 1. Power down the AWS workstation. Note: Connection or disconnection of the bar code scanner USB cable while the AWS workstation is powered on can cause damage to the bar code reader and/or the AWS workstation. 2. Connect the USB-pin male connector of the Bar Code Scanner cable to the USB connector of the AWS workstation rear panel. See Configuration for V1/V2 Control Stations on page 717, Configuration for V3 Control Stations on page 718 or Configuration for V4 Control Stations on page 719 above for the position of the USB connector. 3. Route the Bar Code Scanner cable up the right side of the Control Station framework and secure it to the framework using cable ties. Cable Ties 4. Place the bar code scanner on top of the Control Station. At this stage you do not put the Omega covers back on the Control Station. The illustration below shows where you will route the cable through the side of the Omega cover when they are re-installed. Optional bar code Scanner Chapter 7 Page no. 720 JC-ELE-A-042.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A042 - Bar Code Scanner (Option) 6-6-1 Check Installation • Before trying to use the scanner, ensure that all cable connections are secure. • Power up the AWS workstation and wait until the login prompt appears. • The Bar Code Scanner beeps when it initalizes. The sound of the initializing beep is different to the that when scanning a bar code. 6-6-2 Scan a Bar Code Symbol 1. Go to the Patient List on the AWS Browser. Create a new patient, and click in a field of the Medical Procedure Card. 2. Hold the scanner handle horizontally directly over the bar code printed below. 3. Press the scanner trigger located below the scanner handle; the scanner red LED beam lights. The scanner has successfully scanned the symbol if: - You hear a beep. - The LED beam turns off. Page no. 721 JC-ELE-A-042.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A042 - Bar Code Scanner (Option) 6-6-3 Set Default Configuration Use the scanner to scan the symbols below in the order given to activate the scanner and decoder default configuration. Refer to the scanner documentation and/or the AWS operator manual to activate other functions if necessary. 1. Reset the bar code scanner to factory settings. After scanning, wait until you hear a beep. 3800LX-14 Models 3800G Models 2. Set language to English. Start Language setting: Language is English: 3. Save settings. 4. End settings (two beeps). Go directly to Section 6-7 to complete a Medical Procedure Card. Chapter 7 Page no. 722 JC-ELE-A-042.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A042 - Bar Code Scanner (Option) 6-7 Complete a Medical Procedure Card Perform the following procedure to check for correct installation and configuration of the scanner. 1. Power up the AWS and when prompted at the command line Login: prompt, login as the sdc user as follows: a. At the Login: prompt, enter: sdc b. At the Password: prompt, press the key. 2. At the AWS login screen, select clinical from the Username drop-down field, type clinical in the Password field and click the OK button. 3. Wait until the Browser to appear. 4. Request a new exposure and open the Medical Procedure Card (MPC). 5. Click the first text input field Last Name with the left mouse button to set the keyboard focus. 6. Complete the MPC by scanning all the symbols given on the following page in order, scanning left-toright/top-down. As the MPC user interface can change from one AWS release to another, the layout and entries given in these symbols are templates only: field values are not meaningful and can have any value. To go to (change focus to) the next input field, scan the $I bar code symbol. Page no. 723 JC-ELE-A-042.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A042 - Bar Code Scanner (Option) 7. On completion, the Medical Procedure Card appears like the image below. Medical Procedure Card PATIENT Last Name : Save First Name :: Cancel Patient ID : Birth Date : Sex : Start Exam Male Female Other PROCEDURE Study ID : Study Description : Accession Number : Procedure Description : Operator : Performing Physician : Referring Physician : Scheduled date & time : Chapter 7 Jan 05 2000 16:45 Page no. 724 JC-ELE-A-042.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A042 - Bar Code Scanner (Option) Enter a date manually. Page no. 725 JC-ELE-A-042.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A042 - Bar Code Scanner (Option) Chapter 7 Page no. 726 JC-ELE-A-042.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A042 - Bar Code Scanner (Option) 6-8 • • What If… If nothing happens when you follow the operating instructions: - Check the system power. - Check for loose cable connections. If the scanner does not scan a bar code symbol: - Ensure that the scanning system is programmed to scan the type of bar code you are trying to scan. Refer to Section 6-6-3. - Check that the bar code symbol is not defaced. - The scan head must touch and cover every bar and space on the symbol as shown below. You can tilt the scanner forward or backward to achieve a successful decode. Simple practice quickly shows what tolerances to work within. Right Wrong Page no. 727 JC-ELE-A-042.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A042 - Bar Code Scanner (Option) This page is blank. Chapter 7 Page no. 728 JC-ELE-A-042.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration Job Card ELE A043 - AWS Monitor Calibration 1 Chapter 7 SUPPLIES None 2 TOOLS A calibrated Luminance Meter that permits measuring the luminance of the monitor in contact (Direct) mode as illustrated below. Remove canon and place foam ring Luminance Meter • Siemens Serial Spot Meter (P/N 2319223) must be used with the foam ring attached, and must be configured in Direct mode. Foam Ring Direct mode selected Away/Direct mode button selector • 3 The Away/Direct button toggles between away and direct modes. To select the Direct mode, keep pressing the Away/Direct button until D is displayed on the lower left corner of the Spot Meter screen. REQUIRED EFFORT Personnel: 1 Field Engineer Time: 40 minutes Page no. 729 JC-ELE-A-043.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration 4 APPLICABILITY This Job Card must be applied for all the systems with: • the Stereotaxy option • the 2D Biopsy Optical Localizer option For systems with those options, this Job Card must be applied during the installation of the system, then on a yearly basis. This Job Card must also be applied whenever a display problem on AWS is suspected. This Job Card only applies to V1/V2 Control Stations running ADS 32.04 or greater, V3 Control Stations running ADS 53.40 or greater, and V4 Control Stations. 5 SAFETY PRECAUTIONS No specific safety precautions are applicable. 6 PREREQUISITES Before beginning the calibration procedure, check which configuration you have: • Monitor size: (18" or 19") • Control Station type: CS V1/V2 or CS V3/V4 The monitor OSD menu and the calibration procedure depends on whether it is connected via DVI (V3/ V4 Control Station) or via BNC (V1/V2 Control Station). The steps in this Job Card vary according to your system configuration. • Refer to section 7, 18" Monitors on page 731 to calibrate 18" Monitors. • Refer to section 8, 19" Monitors on page 742 to calibrate 19" Monitors. Chapter 7 Page no. 730 JC-ELE-A-043.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration 7 18" MONITORS The table below summarizes the steps required to calibrate an 18" Monitor. Control Monitor Station Keypad 7-1 1 V3/V4 2 V1/V2 7-1 Unlocking OSD Preliminary Configuration Display SMPTE Move OSD Calibration 7-2 7-3 7-4 7-5 7-6-1 7-6-2 18" Monitor Keypad Usage The monitor keypad at the bottom right corner of the monitor has four buttons, whose functionality is summarized below. Button Action Reference in this Job Card Display main menu or select a sub-menu MENU Enter a sub-menu or increase a value or validate changes UP Decrease a value DOWN Jump to upper menu or exit a menu SET Page no. 731 JC-ELE-A-043.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration 7-2 Unlocking and Locking the On Screen Display (OSD) on 18" Monitors If the message OSD Locked appears on the AWS Monitor when pressing any of the keypads, you can unlock the OSD with the following button sequence: • Press the SET button once then press the UP button three times. You can also use the same button sequence to lock the OSD. • After unlocking the OSD, press the MENU button once to open ths OSD menu. 7-3 Preliminary Configuration Checks on 18" Monitors 1. Press the MENU button to access the OSD main menu, then keep pressing the MENU button until Service level 2 is selected. With monitor connected via DVI (V3/V4 CS) With monitor connected via BNC (V1/V2 CS) 2. Press the UP button once, then immediately press and hold the DOWN button until the Service level 2 menu re-appears as shown below. . 3. From the Service level 2 menu, keep pressing the MENU button until Test and Reset is selected, and press the UP button to enter the Test and Reset menu. 4. From the Test and Reset menu, keep pressing the MENU button until Reset to factory defaults is selected, and press the UP button to select that option. The AWS monitor restarts with the factory settings. Chapter 7 Page no. 732 JC-ELE-A-043.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration 5. If necessary, unlock the OSD (see section 7-2) and move the OSD to a convenient position (see section 7-5). 6. Re-enter the Service level 2 menu again (as explained in steps 1 to 4 above). 7. From the Service level 2menu, keep pressing the MENU button so select the Calibration menu, and press the UP button to enter the Calibration menu. 8. In the Calibration menu, verify that the Lut Backlight command value is set to OFF and the Select display function is set to 4 LUT 1. INCORRECT INCORRECT CORRECT CORRECT If these values are set not as recommended: • change them by selecting it with the MENU button and change it to the correct value with the UP button • store the changed settings by pressing the SET button until Accept changes is selected, then press the UP button to exit and save the settings. 9. Once the changed settings are saved, go to section 7-4 for the 18" monitor. Page no. 733 JC-ELE-A-043.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration 7-4 Display the SMPTE Test Pattern Display the SMPTE pattern on the AWS Monitor by using the following steps: 1. From the Browser, launch the Service Desktop (see Launching the Service Desktop on page 120). 2. From the Service Desktop, click the Calibration button and select Peripherals/AWS monitor, then click the START button to display the SMPTE Test Pattern. Central black level square used to do the monitor brightness adjustment. Central white level square used to do the monitor backlight adjustment, and contrast adjustment. 3. Ensure that the mouse cursor is in the image of the SMPTE Test Pattern so that is correctly displayed. Note: Do NOT use the "FFDM pattern" that is accessible from the browser patient list. 4. Once the SMPTE Test Pattern is displayed, go to section 7-5. 7-5 Move the OSD to a Convenient Position on 18" Monitors It may be desirable to move the OSD display toward the upper part of the screen to fully observe the following squares of the SMPTE pattern: • central white level square • central black level square • 5% / 0% grey level square Chapter 7 Page no. 734 JC-ELE-A-043.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration • 95% / 100% grey level square The image below represents a good example of OSD menu position with respect to the SMPTE pattern displayed. The OSD menu does not cover the central white level square used to do the monitor contrast, brightness or backlight adjustment. 1. If the OSD main menu is already in a good position, go to step 6. 2. Press the MENU button to access the OSD main menu, then keep pressing the MENU button until Others is selected, and press the UP button to enter the Others menu. With monitor connected via DVI (V3/V4 CS) With monitor connected via BNC (V1/V2 CS) Page no. 735 JC-ELE-A-043.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration 3. From the Others menu, keep pressing the MENU button until OSD Settings is selected, and press the UP button to enter the OSD Settings menu. With monitor connected via DVI (V3/V4 CS) With monitor connected via BNC (V1/V2 CS) 4. From the OSD Settings menu, keep pressing the MENU button until Vertical Position is selected, and then keep pressing the UP/DOWN button until the position of the OSD is towards the top of the screen. 5. When you have reached the desired position for the OSD, keep pressing the SET button until Accept changes is selected, then press the UP button to exit and save the settings. 6. Once the OSD menu is in a convenient position, proceed as follows: • If you have a V3/V4 Control Station, go to section 7-6-1 for the 18" monitor • If you have a V1/V2 Control Station, go to section 7-6-2 for the 18" monitor Chapter 7 Page no. 736 JC-ELE-A-043.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration 7-6 Calibration 7-6-1 18" Monitor and V3/V4 Control Station 1. The SMPTE pattern is already displayed on the AWS Monitor. If not, refer to section 7-4 to display the SMPTE pattern. 2. Press the MENU button to access the OSD main menu, then keep pressing the MENU button until Auto functions is selected. Press the UP button to enter the Auto functions menu. Press the UP button again to perform an auto-calibration. The auto-calibration takes place. 3. Press the MENU button to access the OSD main menu, then keep pressing the MENU button until Service level 2 is selected. 4. Press the UP button once, then immediately press and hold the DOWN button until the Service level 2 menu re-appears as shown below. Keep pressing the MENU button until User Settings is selected. Page no. 737 JC-ELE-A-043.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration 5. Press the UP button to display the User Settings menu. Keep pressing the MENU button until Reset User settings is selected, and press the UP button to execute Reset User settings. The AWS monitor restarts. 6. Unlock the OSD (see section 7-2) and move the OSD to a convenient position (see section 7-5) if necessary. 7. Press the MENU button to access the OSD main menu, then keep pressing the MENU button until Brightness/Contrast is selected, and press the UP button to enter the RGB menu. The RGB menu appears. 8. Do not change the default Brightness and Contrast values that appear in the RGB menu. The default Brightness and Contrast values vary according to the monitor release as follows: • 50 for the Brightness and 50 for the Contrast • 37 for the Brightness and 24 for the Contrast Chapter 7 Page no. 738 JC-ELE-A-043.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration 9. Perform a monitor backlight adjustment, as follows: a. Stay in the RGB menu, and keep pressing the MENU button until Backlight is selected. b. With the luminance meter positioned on the central white level square of the SMPTE pattern (see the image in section 7-4), use the UP/DOWN buttons to adjust the Backlight value of the RGB menu so that the luminance of the white level meets the target luminance of 400 cd/m² ±10 cd/m². 10. Keep pressing the SET button until Accept changes is selected, then press the UP button to exit and save the settings. 7-6-2 18" Monitor and V1/V2 Control Station 1. The SMPTE pattern is already displayed on the AWS Monitor. If not, refer to section 7-4 to display the SMPTE pattern. 2. Press the MENU button to access the OSD main menu, then keep pressing the MENU button until Auto functions is selected. Press the UP button to enter the Auto functions menu. Press the UP button again to perform an auto-calibration. The auto-calibration takes place. 3. Press the MENU button to access the OSD main menu, then keep pressing the MENU button until Page no. 739 JC-ELE-A-043.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration Brightness/Contrast is selected, and press the UP button to enter the RGB menu. The RGB menu appears. 4. Perform a Monitor brightness adjustment, as follows: a. Stay in the RGB menu, and keep pressing the MENU button until Brightness is selected. b. With the luminance meter positioned on the central black level square of the SMPTE pattern (see the image in section 7-4), use the DOWN button to decrease the Brightness value until the luminance measured stops changing. Then, use the UP/DOWN buttons to verify that the luminance measured is at the limit between not changing and decreasing (see the image below which illustrates this adjustment). Measured lumniance (on black level square) Down Up/Down buttons to find limit where measured liminance is at the limit between not changing and decreasing. Decreasing brightness (Brightness value displayed on Monitor OSD) 5. Perform a Monitor contrast adjustment, as follows: a. Stay in the RGB menu, and keep pressing the MENU button until Contrast is selected. b. With the luminance meter positioned on the central white level square of the SMPTE pattern (see the image in section 7-4), use the UP button to adjust the Contrast value until the luminance measured stops changing. Then use the UP/DOWN buttons to verify that the luminance measured is at the limit between not changing and increasing (see the image below which illustrates this Chapter 7 Page no. 740 JC-ELE-A-043.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration adjustment). Up/Down buttons to find limit where measured liminance is at the limit between not changing and increasing. Measured lumniance (on white level square) Up Increasing contrast (Inreasing value displayed on Monitor OSD) 6. Perform a Monitor backlight adjustment, as follows: a. Stay in the RGB menu, and keep pressing the MENU button until Backlight is selected. b. With the luminance meter positioned on the central white level square of the SMPTE pattern (see the image in section 7-4), use the UP/DOWN buttons to adjust the Backlight value so that the luminance of the white level meets the target luminance of 400 cd/m² ±10 cd/m². 7. Perform a grey-level visibility check on the SMPTE pattern, by checking that: • All the grey levels are visible • The "5%" square remains visible compared to the 0% square. • The "95%" square is visible compared to the 100% square. If you do not have these results, repeat the calibration steps 2 to 6. 8. Keep pressing the SET button until Accept changes is selected, then press the UP button to exit and save the settings. Page no. 741 JC-ELE-A-043.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration 8 19" MONITORS The table below summarizes the steps required to calibrate an 19" Monitor. Control Monitor Station Keypad 8-1 1 V3/V4 2 V1/V2 Unlocking OSD Preliminary Configuration Display SMPTE Move OSD Calibration 8-2 8-3 8-4 8-5 8-6-1 8-1 8-6-2 19" Monitor Keypad Usage The monitor keypad at the bottom right corner of the monitor has four buttons, whose functionality is summarized below. Button Case Action Reference in this Job Card 1 Always Scroll Key1 2 Submenu is highlighted Select the submenu Key2 Function is selected Increase / change the value 3 Function is selected Decrease / change the value Key3 4 Except in the Exit OSD menu Jump one menu level back (settings are retained) Key4 In the Exit OSD menu Return to main menu (settings are retained) Chapter 7 Page no. 742 JC-ELE-A-043.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration 8-2 Unlocking and Locking the On Screen Display (OSD) for 19" Monitors If the message OSD Locked appears on the AWS Monitor when pressing any of the keypads, or if you can only access the Hotkey menu (see image below) the monitor is locked. You can unlock the OSD with the following button sequence: • Press the Key4 button once then press the Key2 button three times. You can also use the same button sequence to lock the OSD. • After unlocking the OSD, press the Key1 button once to open ths OSD menu. Page no. 743 JC-ELE-A-043.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration 8-3 Preliminary Configuration Checks for 19" Monitors 1. Unlock the OSD (see section 8-2) and move the OSD to a convenient position (see section 8-5) if necessary. 2. Press the Key1 button to access the OSD main menu, then keep pressing the Key1 button until Service level 2 is selected. With monitor connected via BNC (V1/V2 CS) With monitor connected via DVI (V3/V4 CS) 3. Press the Key2 button once, then immediately press and hold the Key3 button until the Service level 2 menu re-appears as shown below. With monitor connected via DVI (V3/V4 CS) With monitor connected via BNC (V1/V2 CS) 4. From the Service level 2 menu, keep pressing the Key1 button until Test and Reset is selected, and Chapter 7 Page no. 744 JC-ELE-A-043.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration press the Key2 button to enter the Test and Reset menu. 5. From the Test and Reset menu, keep pressing the Key1 button until Reset to factory defaults is selected, and press the Key2 button to select that option. The AWS monitor restarts with the factory settings. 6. Unlock the OSD (see section 8-2) and move the OSD to a convenient position (see section 8-5) if necessary. 7. Press the Key1 button to access the OSD main menu, then keep pressing the Key1 button until Others is selected. With monitor connected via DVI (V3/V4 CS) With monitor connected via BNC (V1/V2 CS) 8. Press the Key2 button to enter the Others menu, then keep pressing the Key1 button until LUT settings is selected, then press the Key2 button to enter the LUT settings menu. 9. In the LUT settings menu, verify that the Lut Backlight command value is set to OFF and the Select Page no. 745 JC-ELE-A-043.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration display function is set to 4. INCORRECT INCORRECT CORRECT CORRECT If these values are set not as recommended: • change them by selecting it with the Key1 button and change it to the correct value with the Key2 button • store the changed settings by pressing the Key4 button until Accept changes is selected, then press the Key2 button to exit and save the settings. 10. Once the changed settings are saved, go to section 8-3 for the 19" monitor. Chapter 7 Page no. 746 JC-ELE-A-043.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration 8-4 Display the SMPTE Test Pattern on 19" Monitors Display the SMPTE pattern on the AWS Monitor by using the following steps: 1. From the Browser, launch the Service Desktop (see Launching the Service Desktop on page 120). 2. From the Service Desktop, click the Calibration button and select Peripherals/AWS monitor, then click the START button to display the SMPTE Test Pattern. Central black level square used to do the monitor brightness adjustment. Central white level square used to do the monitor backlight adjustment, and contrast adjustment. 3. Ensure that the mouse cursor is in the image of the SMPTE Test Pattern so that is correctly displayed. Note: Do NOT use the "FFDM pattern" that is accessible from the browser patient list. 4. Once the SMPTE Test Pattern is displayed, go to section 8-5. Page no. 747 JC-ELE-A-043.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration 8-5 Move the OSD to a Convenient Position on 19" Monitors It may be desirable to move the OSD display toward the upper part of the screen to fully observe the following squares of the SMPTE pattern: • central white level square • central black level square • 5% / 0% grey level square • 95% / 100% grey level square The image below represents a good example of OSD menu position with respect to the SMPTE pattern displayed. The OSD menu does not cover the central white level square used to do the monitor contrast, brightness or backlight adjustment. 1. If the OSD main menu is already in a good position, go to step 5. 2. Press the Key1 button to access the OSD main menu, then keep pressing the Key1 button until OSD Chapter 7 Page no. 748 JC-ELE-A-043.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration / LED settings is selected, and press the Key2 button to enter the OSD / LED settings menu. With monitor connected via DVI (V3/V4 CS) With monitor connected via BNC (V1/V2 CS) 3. From the OSD / LED settings menu, keep pressing the Key1 button until Vertical Position is selected, and press the Key2/Key3 button until the position of the OSD is towards the top of the screen. 4. When you have reached the desired position for the OSD, keep pressing the Key4 button until Exit OSD appears. Then keep pressing the Key1 button until Accept changes is selected, then press the Key2 button to exit and save the settings. 5. Once the OSD menu is in a convenient position, proceed as follows: • If you have a V3/V4 Control Station, go to section 8-6-1 for the 19" monitor. • If you have a V1/V2 Control Station, go to section 8-6-2 for the 19" monitor. Page no. 749 JC-ELE-A-043.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration 8-6 Calibration on 19" Monitors 8-6-1 19" Monitor and V3/V4 Control Station 1. The SMPTE pattern is already displayed on the AWS Monitor. If not, refer to section 8-4 to display the SMPTE pattern. 2. If necessary, unlock the OSD (see section 8-2) and move the OSD to a convenient position (see section 8-5). 3. Press the Key1 button to access the OSD main menu, then keep pressing the Key1 button until Brightness / Contrast is selected, and press the Key2 button to enter the Brightness / Contrast menu. The Brightness/Contrast appears. The Brightness and the Contrast are both set to 50, and cannot be changed. 4. With the Backlight slider already selected, peform a monitor backlight adjustment. With the luminance meter positioned on the central white level square of the SMPTE pattern (see the image in section 8-4), use the Key2/Key3 buttons to adjust the Backlight value of the Brightness / Contrast menu so that the luminance of the white level meets the target luminance of 400 cd/m² ±10 cd/m². 5. Keep pressing the Key4 button until Accept changes is selected, then press the Key2 button to exit and save the settings. Chapter 7 Page no. 750 JC-ELE-A-043.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration 8-6-2 19" Monitor and V1/V2 Control Station 1. The SMPTE pattern is already displayed on the AWS Monitor. If not, refer to section 8-4 to display the SMPTE pattern. 2. If necessary, unlock the OSD (see section 8-2) and move the OSD to a convenient position (see section 8-5). 3. Press the Key1 button to access the OSD main menu, then keep pressing the Key1 button until Auto functions is selected, and press the Key2 button to enter the Auto functions menu. 4. In the Auto functions menu, keep pressing the Key1 button until Execute selected auto functions is selected, and press the Key2 button to perform an auto calibration. The auto-calibration takes place. 5. If necessary, unlock the OSD (see section 8-4) and move the OSD to a convenient position (see section 8-5). 6. Press the Key1 button to access the OSD main menu, then keep pressing the Key1 button until Brightness / Contrast is selected, and press the Key2 button to enter the Brightness / Contrast menu. Page no. 751 JC-ELE-A-043.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration The Brightness/Contrast menu appears. 7. Perform a Monitor brightness adjustment, as follows: a. Stay in the Brightness/Contrast menu, and keep pressing the Key1 button until Brightness is selected. b. With the luminance meter positioned on the central black level square of the SMPTE pattern (see the image in section 8-4), use the Key3 button to decrease the Brightness value until the luminance measured stops changing. Then, use the Key2/Key3 buttons to verify that the luminance measured is at the limit between not changing and decreasing (see the image below which illustrates this adjustment). Measured lumniance (on black level square) Key 3 Key2/Key3 buttons to find limit where measured liminance is at the limit between not changing and decreasing. Decreasing brightness (Brightness value displayed on Monitor OSD) 8. Perform a Monitor contrast adjustment, as follows: a. Stay in the Brightness/Contrast menu, and keep pressing the Key1 button until Contrast is selected. b. With the luminance meter positioned on the central white level square of the SMPTE pattern (see the image in section 8-4), use the Key2 buttons to increase the Contrast value until the luminance measured stops changing. Then use the Key2/Key3 buttons to verify that the luminance measured is at the limit between not changing and increasing (see the image below which illustrates Chapter 7 Page no. 752 JC-ELE-A-043.fm GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration this adjustment). Key2/Key3 buttons to find limit where measured liminance is at the limit between not changing and increasing. Measured lumniance (on white level square) Key2 Increasing contrast (Inreasing value displayed on Monitor OSD) 9. Perform a Monitor backlight adjustment, as follows: a. Stay in the Brightness/Contrast menu, and keep pressing the Key1 button until Backlight is selected. b. With the luminance meter positioned on the central white level square of the SMPTE pattern (see the image in section 8-4), use the Key2/Key3 buttons to adjust the Backlight value so that the luminance of the white level meets the target luminance of 400 cd/m² ±10 cd/m². 10. Perform a grey-level visibility check on the SMPTE pattern, by checking that: • All the grey levels are visible • The "5%" square remains visible compared to the 0% square. • The "95%" square is visible compared to the 100% square. If you do not have these results, repeat the calibration steps 2 to 9. 11. Keep pressing the Key4 button until Accept changes is selected, then press the Key2 button to exit and save the settings. Page no. 753 JC-ELE-A-043.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A043 - AWS Monitor Calibration This page is blank. Chapter 7 Page no. 754 JC-ELE-A-043.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A044 - Install User Publications Job Card ELE A044 - Install User Publications 1 Chapter 7 SUPPLIES User Publications CD-ROM(s) 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 10 minutes 4 SAFETY PRECAUTIONS No specific safety precautions are applicable. 5 PREREQUISITES None 6 STEERING GUIDE The number of User Publications CD-ROMs that are delivered with the system depend on the options ordered with the Senographe system. There is always a Core User Publications CD-ROM, and there may be one or more Options User Publications CD-ROMs. 1. Firstly, install the Core User Publications using the instructions described in section 7 of this Job Card. 2. Then if supplied, install the each of the Options User Publications using the instructions described in section 7 of this Job Card. 3. Once all Core and Options User Publications are installed, restart the Browser (see Restarting the Browser on page 119). 7 PROCEDURE Use the following steps to install the User Publications (Core or Options) on the Senographe System. 1. Insert the User Publications CD-ROM into the DVD-ROM of the ADS Computer. 2. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 3. Log in as root as follows: a. At the ADS prompt enter: su b. When requested to specify the root password, enter: operator 4. Change to the ~sdc/senovision/scripts directory, by entering: cd ~sdc/senovision/scripts Page no. 755 JC-ELE-A-044.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A044 - Install User Publications 5. Run the install.edoc script by entering: install.edoc Note: If you attempt to install an Options User Publications before the Core User Publications, the command line responds with an appropriate error message. 6. Once the installation script completes, remove the User Publications CD-ROM from the DVD-ROM of the ADS Computer. 8 COMPLETION 1. Check that the Access to Publications button is present in the Browser. Note: If the Access to Publications button is not present, ensure that you have restarted the Browser. Dicom IC_LMO Dicom JFR_RWSS CDR GE Medical Systems No Remaining Save) and click the button in the top left of the TextEdit window to exit the editor. 10. Copy the newly modified /etc/inet/hosts file to the /export/home/extra_tmp/IPbak directory for backup purposes, by entering: cp /etc/inet/hosts /export/home/extra_tmp/IPbak/hosts.new 11. Ensure that /etc/hosts is a symbolic link to /etc/inet/hosts, by using the following sub-steps: a. List all the symbolic links associated with the /etc/hosts file by entering: ls -l /etc/hosts b. Review the command line output. If the command line output Then begins with lrwxrwxrwx and finishes with hosts -> ./inet/hosts the symbolic link is set and you can go to step 12 does not begin with lrwxrwxrwx and does not finish with hosts -> ./inet/hosts the symbolic link is not set and you must go to sub-step c c. Remove the /etc/hosts file without prompting for confirmation, regardless of the file's permissions, by entering: rm -f /etc/hosts d. Create a symbolic link from /etc/hosts is to /etc/inet/hosts by entering: ln -s /etc/inet/hosts /etc/hosts Chapter 7 Page no. 764 JC-ELE-A-050.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A050 - Changing Senographe Internal IP Addresses 12. Copy the original ~sdc/senovision/scripts/light_adjustment file to the /export/home/extra_tmp/IPbak directory for backup purposes, by entering: cp ~sdc/senovision/scripts/light_adjustment /export/home/extra_tmp/IPbak/ light_adjustment.original 13. Open the ~sdc/senovision/scripts/light_adjustment file with the textedit command by entering: textedit ~sdc/senovision/scripts/light_adjustment The ~sdc/senovision/scripts/light_adjustment file appears in an X-Windows based TextEdit application window. Edit IP Address 14. Within the TextEdit application window, scroll down to the last line of the ~sdc/senovision/scripts/ light_adjustment script. Then change the reference of http://192.168.1.10 to match the new address of the AWS (e.g. 192.168.100.10). 15. Save the ~sdc/senovision/scripts/light_adjustment file (File > Save) and click the button in the top left of the TextEdit window to exit the editor. 16. Copy the newly modified ~sdc/senovision/scripts/light_adjustment file to the /export/home/extra_tmp/ IPbak directory for backup purposes, by entering: cp ~sdc/senovision/scripts/light_adjustment /export/home/extra_tmp/IPbak/ light_adjustment.new 17. Copy the original ~sdc/senovision/config/PositionerServer.cfg file to the /export/home/extra_tmp/ IPbak directory for backup purposes, by entering: cp ~sdc/senovision/config/PositionerServer.cfg /export/home/extra_tmp/ IPbak/PositionerServer.cfg.original 18. Open the ~sdc/senovision/config/PositionerServer.cfg file with the textedit command by entering: textedit ~sdc/senovision/config/PositionerServer.cfg The ~sdc/senovision/config/PositionerServer.cfg file appears in an X-Windows based TextEdit appli- Page no. 765 JC-ELE-A-050.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A050 - Changing Senographe Internal IP Addresses cation window. Edit IP Address 19. Within the TextEdit application window, scroll down to the INET_ADDR parameter located in the [ConfigSPLine] section of the ~sdc/senovision/config/PositionerServer.cfg file. Then change the reference of 192.168.1.40 to match the new address of the Poseidon (Gantry CPU) (e.g. 192.168.100.40). 20. Save the ~sdc/senovision/config/PositionerServer.cfg file (File > Save) and click the button in the top left of the TextEdit window to exit the editor. 21. Copy the newly modified ~sdc/senovision/config/PositionerServer.cfg file to the /export/home/ extra_tmp/IPbak directory for backup purposes, by entering: cp ~sdc/senovision/config/PositionerServer.cfg /export/home/extra_tmp/ IPbak/PositionerServer.cfg.new 22. Copy the original /export/home/insite/svcproxy_env.cmd file to the /export/home/extra_tmp/IPbak directory for backup purposes, by entering: cp /export/home/insite/svcproxy_env.cmd /export/home/extra_tmp/IPbak/ svcproxy_env.cmd.original 23. Open the /export/home/insite/svcproxy_env.cmd file with the textedit command by entering: textedit /export/home/insite/svcproxy_env.cmd The /export/home/insite/svcproxy_env.cmd file appears in an X-Windows based TextEdit application Chapter 7 Page no. 766 JC-ELE-A-050.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A050 - Changing Senographe Internal IP Addresses window. Edit all IP Addresses 24. Within the TextEdit application window, change the all of the current Senographe system IP addresses from 192.168.1.x to match your preferred new address scheme (e.g. 192.168.100.x). 25. Save the /export/home/insite/svcproxy_env.cmd file (File > Save) and click the button in the top left of the TextEdit window to exit the editor. 26. Copy the newly modified /export/home/insite/svcproxy_env.cmd file to the /export/home/extra_tmp/ IPbak directory for backup purposes, by entering: cp /export/home/insite/svcproxy_env.cmd /export/home/extra_tmp/IPbak/ svcproxy_env.cmd.new 27. Log in as root as follows: a. At the ADS prompt enter: su b. When requested to specify the root password, enter: operator 28. Revert the permissions of some of the ADS configuration files back to their original state, as follows: a. Change the /etc/inet/hosts file to its original permissions, by entering: chmod o-w /etc/inet/hosts b. Change the ~sdc/senovision/scripts/light_adjustment file to its original permissions, by entering: chmod u-w ~sdc/senovision/scripts/light_adjustment c. Change the ~sdc/senovision/config/PositionerServer.cfg file to its original permissions, by entering: chmod u-w ~sdc/senovision/config/PositionerServer.cfg 29. Exit as root user to return to sdc user, by entering: exit You are returned to the command prompt as sdc user. Page no. 767 JC-ELE-A-050.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A050 - Changing Senographe Internal IP Addresses 30. Reboot the system for the changes to take effect by entering: reboot 31. From the Browser, launch the Service Desktop (see Launching the Service Desktop on page 120), and ensure that the Service Desktop is working as expected. 32. Shut down and power up the entire Senographe system. 33. After the reboot has completed, an S61 X-ray Beam not ready error message may appear on the Xray Console. This occurs because the Gantry CPU has to boot up after the ADS computer. To restore communication between the Gantry CPU and the ADS computer, on the X-ray Console press the O (off) button and then press the I (on) button. 7-7 Copy Backup Files from the IPbak Directory to Floppy Disk or CD-R Copy the backup files you made in /export/home/extra_tmp/IPbak to either floppy diskette or CD-R by following the steps in the appropriate section. Note: No floppy disk drive exists on the V3/V4 Control Station, so you must use the CD-R media on V3/ V4 Control Stations. 7-7-1 Copying Backup Files to Floppy Disk To copy the backup files to floppy disk, proceed as follows: 1. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). 2. Insert a blank DOS formatted floppy diskette in AWS floppy disk drive. 3. Log in as root as follows: a. At the ADS prompt enter: su b. When requested to specify the root password, enter: operator 4. Mount the floppy disk drive to /floppy, by entering: mount -f pcfs /dev/fd0 /floppy 5. Make an IPbak directory on the floppy disk, by entering: mkdir /floppy/IPbak 6. Copy the entire contents of the /export/home/extra_tmp/IPbak directory, by entering: cp /export/home/extra_tmp/IPbak/* /floppy/IPbak 7. Logout as the root user, by entering: exit You are returned to the command prompt as the sdc user. 8. Unmount the floppy disk drive, by entering: umount /floppy 9. Eject the floppy diskette which contains all of the original backed up files, by entering: eject Chapter 7 Page no. 768 JC-ELE-A-050.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A050 - Changing Senographe Internal IP Addresses 7-7-2 Copying the Backup Files to CD-R Note: The use of a writable CD-R disk is only possible from ADS versions 31.27 and above. To copy the backup files to CD-R proceed as follows: Note: Since the V3/V4 Control Station does not contain a floppy disk drive, you must use the steps in this section if you are copying log files on V3/V4 Control Stations. Use the following steps to copy the Senographe system log files to a writable CD-R disk. 1. Insert a writable CD-R disk into the Senographe system writable CD-ROM drive. 2. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 3. Run the BurnCdr.sh script to copy the contents of the /export/home/extra_tmp/IPbak directory to the CD-R disk, with a CD volume name of your choice, by entering: BurnCdr.sh -i -k -v /export/home/extra_tmp/IPbak/ where is your preferred name for the CD volume name (e.g. IPbackup). 4. Once the BurnCdr.sh script completes copying the log files to the CD-R disk, you are prompted to eject the CD-ROM. Accept the prompt, remove the CD-R disk from the CD-ROM drive and close the CD-ROM drive. 5. Exit the command window by entering: exit The command window closes. 8 COMPLETION Make a noticeable entry in the maintenance log book that the internal IP addresses of the Senographe system have been changed. Explain to the customer that each time they power on the Senographe system they may see the following message on the X-ray Console: • S61 X-ray Beam not ready Explain to them that this is normal and due to the fact that the Gantry CPU has to boot up after the ADS computer. Explain to the customer that a simple reboot of the Gantry CPU removes the error and restores communication between the Gantry CPU and the ADS computer. Explain to the customer that once the system has fully powered up, that on they X-ray Console they simply have to press the O (off) button and then press the I (on) button. You can demonstrate this to them as follows: 1. Power off the Senographe system from the ADS software interface. 2. Power on the system from the X-ray Console (press the I (on) button). 3. Login as sdc so that the ADS software is running. 4. Point out the S61 X-ray Beam not ready error message on the X-ray Console. 5. Press the O (off) button on the X-ray Console (this action powers down the Gantry CPU but not the ADS Computer). 6. Press the I (on) button on the X-ray Console (this action powers on the Gantry CPU which then establishes a network connection with the ADS Computer). 7. Point out that the S61 X-ray Beam not ready error message no longer appears on the X-ray Console. Page no. 769 JC-ELE-A-050.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A050 - Changing Senographe Internal IP Addresses 9 STEERING GUIDE FOR FUTURE COMPONENT UPGRADES If you ever upgrade the software on any of the Senographe components in the future you must ensure that the internal IP addresses are reconfigured back to their default values before you run the software upgrade for that component. To do this you would proceed as described in the following sub section. 9-1 Steering Guide for Future AWS Software Upgrades on the ADS Computer If you want to upgrade the AWS Workstation software on the ADS Computer, proceed as follows: • Perform Section 7-6, page 762 to reconfigure each of the files on the ADS Computer back to their default 192.168.1.0 network address scheme. • Run the upgrade of the AWS Workstation software on the ADS Computer. • Perform Section 7-6, page 762 to reconfigure each of the files on the ADS Computer back to your preferred network address scheme (e.g. 192.168.100.0 network). 9-2 Steering Guide for Future Software Upgrades on the IDC If you want to upgrade the software on the IDC, proceed as follows: • Perform Section 1, page 758 to reconfigure the IDC back to the default IP address of 192.168.1.20. • Perform Section 7-6, page 762 to reconfigure each of the files on the ADS Computer back to their default 192.168.1.0 network address scheme. • Run the upgrade of the software on the IDC. • Perform Section 1, page 758 to reconfigure the IDC back to your preferred IP address (e.g. 192.168.100.20). • Perform Section 7-6, page 762 to reconfigure each of the files on the ADS Computer back to your preferred network address scheme (e.g. 192.168.100.0 network). 9-3 Steering Guide for Future Software Upgrades on the Gantry CPU If you want to upgrade the software on the Gantry CPU, proceed as follows: • Perform Section 7-4, page 760 to reconfigure the Gantry CPU back to the default IP address of 192.168.1.40. • Perform Section 7-6, page 762 to reconfigure each of the files on the ADS Computer back to their default 192.168.1.0 network address scheme. • Run the upgrade of the software on the Gantry CPU. • Perform Section 7-4, page 760 to reconfigure the Gantry CPU to your preferred IP address (e.g. 192.168.100.40). • Perform Section 7-6, page 762 to reconfigure each of the files on the ADS Computer back to your preferred network address scheme (e.g. 192.168.100.0 network). Chapter 7 Page no. 770 JC-ELE-A-050.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A052 - Back-up/Restore Procedure Job Card ELE A052 - Back-up/Restore Procedure 1 Chapter 7 SUPPLIES For optionally backing up the AWS parameters to external media: • Blank DOS formatted HD 3.5 floppy disk (for V1/V2 Control Stations) • blank CD-R (for V3/V4 Control Stations) 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 10 minutes 4 SAFETY PRECAUTIONS No specific safety precautions are applicable. 5 PREREQUISITES None 6 BACKUP/RESTORE PROCEDURE Backup and restore procedures are described on the following pages. ! Notice: If backup to floppy disk or CD-R is not possible, it is necessary to record AWS parameters manually so that they can be restored later (e.g., after an upgrade procedure). Refer to Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets on page 801 for a suitable form. ! Notice: An AWS backup from a particular ADS version can only be restored to the same ADS version. Unless it is written in the Upgrade Procedure, it is prohibited to perform a backup and restore from different ADS/IDC versions, since the file structure may vary between the different versions. If you try to restore an ADS/IDC backup to a different version, you will corrupt the AWS/IDC installation and cause system problems. If you are backing up a system before upgrading the ADS version, record the AWS parameters manually so that they can be manually restored later (see Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets on page 801). Page no. 771 JC-ELE-A-052.fm Chapter 7 GE Healthcare Senographe DS Revision 1 Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A052 - Back-up/Restore Procedure 6-1 Introduction The diagram below illustrates the generic backup process. AWS Hard Disk Generator brgen.dat (17 k) AWS Config files browser preferences, hosts declared, printer config., config from Service Desktop, etc. ads.tar (1 M) Optional ads_hd.tar (1 M) iip.data.tar (1 M) iop.tar (100 k) Backup AWS Configuration on external media AWS config floppy ads.tar (1 M) iip.data.tar (10 k) iop.tar (100 k) Backup 1 IDC /export/home/iqst/subsystems/ads/backup/current/ /export/home/iqst/subsystems/dmr/backup/current/ /export/home/iqst/subsystems/idc/backup/current/ Complete directory /idc (160 M) about 200 files V1/V2 Control Stations Next Backup OR Backup 2 /export/home/iqst/subsystems/ads/backup/previous/ /export/home/iqst/subsystems/dmr/backup/previous/ /export/home/iqst/subsystems/idc/backup/previous/ AWS config CD-R ads.tar (1 M) iip.data.tar (10 k) iop.tar (100 k) V3 Control Stations When a backup is performed, the following operations occur: • If Backup 1 files from a previous backup stored in ~/current already exist on the AWS hard disk, they are renamed to Backup 2 stored in ~/previous on the AWS hard disk. • For V1/V2 Control Stations the backup files in ~/previous (Backup 2) are then lost. Whereas for V3/ V4 Control Stations the ~/previous (Backup 2) files are copied to another location (Backup 3). • A new backup file named Backup 1 is created on the AWS hard disk. This contains: - AWS configuration data The numerous AWS configuration files spread in many locations are gathered into four files and copied to Backup 1. - IDC configuration data The IDC directory is copied to Backup 1. - Senographe data Senographe calibration files are copied through the AWS/Senographe serial link to Backup 1. With the Generator parameters, the tube heater current parameters are not saved. • If external media (formatted floppy or CD-R) was optionally inserted then the three AWS configuration files (ads.tar, iip.tar and iop.tar) are copied to the external media. No IDC or Senographe data are written to the external media. Chapter 7 Page no. 772 JC-ELE-A-052.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A052 - Back-up/Restore Procedure It is possible to carry out a restore procedure in the following ways: • AWS configuration data can be restored from floppy diskette Backup 1 or Backup 2. • IDC configuration data can be restored from the AWS disk file Backup 1 or Backup 2. • Senographe data can be restored from the AWS disk file Backup 1 or Backup 2. ! Notice: 1. A system backup is recommended after each change of configuration of any part of the system, and after each set of calibrations. 2. A system backup is not recommended after a single calibration or configuration change when the change is going to be followed by more changes. 3. Each time that a system backup is made, the current AWS file backup Backup 2 is lost (overwritten by Backup 1). This must be taken into account when considering a new backup. 4. Medical Preferences are not saved. They must be noted manually for reinstallation. 7 BACKUP PROCEDURES The backup procedures vary according to the type of Control Station in the system. • Refer to section 7-1, Backup Procedure on V1/V2 Control Stations on page 774 for V1/V2 Control Stations. • Refer to section 7-2, Backup Procedure on V3/V4 Control Stations on page 775 for V3/V4 Control Stations. Page no. 773 JC-ELE-A-052.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A052 - Back-up/Restore Procedure 7-1 Backup Procedure on V1/V2 Control Stations 1. From the Browser, launch the Service Desktop (see Launching the Service Desktop on page 120). 2. From the Service Desktop, click the Utilities button . 3. Insert a blank 3.5" HD floppy disk into the floppy drive on the AWS unit (not the IDC). To access the floppy drive, remove the Control Station front cover and pull back the AWS unit. Click the Floppy Format button, and wait for the format to complete. Note: The presence of a floppy disk is not essential for the backup. If no floppy is inserted, AWS parameters are still copied to the hard disk. 4. Click the Backup button. The Back up screen like the following appears. 5. Enter a suitable name into the text field System Backup Description Text; click the START button to continue. If no floppy disk is present, the message Floppy disk error or not formatted appears; click Continue to continue the backup. The process takes about 10 minutes. 6. An AWS reset is carried out automatically; click OK when it completes. 7. The message System Backup Completed appears at the end of the backup operation. 8. To check that the backup copy is available, click the RESTORE button: The name of the system backup, Backup 1, appears on the screen. 9. If the backup is not completed successfully, refer to section Backup Troubleshooting on page 779. 10. Remove the floppy disk; label it with the name and date of the backup and keep it safely. Chapter 7 Page no. 774 JC-ELE-A-052.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A052 - Back-up/Restore Procedure 7-2 Backup Procedure on V3/V4 Control Stations 1. From the Browser, launch the Service Desktop (see Launching the Service Desktop on page 120). 2. From the Service Desktop, click the Utilities button . 3. Insert a blank CD-R disk into the writable CD-ROM drive on the AWS unit (not the IDC). Note: The presence of a CD-R disk is not essential for the backup. If no CD-R disk is inserted, AWS parameters are still copied to the hard disk. 4. Select System Tools > Backup. The Back up screen like the following appears. 5. Enter a suitable name into the text field System Backup Description Text; click the START button to continue. If no CD-R disk is present, the message CD Mount Error Or CD Not Blank appears; click Continue to continue the backup. The process takes about 10 minutes. 6. An AWS reset is carried out automatically; click OK when it completes. 7. The message System Backup Completed appears at the end of the backup operation. 8. To check that the backup copy is available, click the RESTORE button: The name of the system backup, Backup 1, appears on the screen. 9. If the backup is not completed successfully, refer to section Backup Troubleshooting on page 779. 10. Remove the CD-R disk; label it with the name and date of the backup and keep it safely. Page no. 775 JC-ELE-A-052.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A052 - Back-up/Restore Procedure 8 RESTORE PROCEDURES The restore procedures vary according to the type of Control Station in the system. • Refer to section 8-1, Restore Procedure on V1/V2 Control Stations on page 776 for V1/V2 Control Stations. • Refer to section 8-2, Restore Procedure on V3/V4 Control Stations on page 777 for V3/V4 Control Stations. 8-1 Restore Procedure on V1/V2 Control Stations 1. From the Browser, launch the Service Desktop (see Launching the Service Desktop on page 120). 2. From the Service Desktop, click the Utilities button . 3. Click the Restore button: the Restore screen like the following appears. 4. Select the appropriate restore procedure: you can restore separate sub-system data (AWS, IDC, or Senographe) as required. 5. Select the data source (Backup1 or Backup 2 on the AWS disk or 3.5" floppy). 6. If you are restoring from a floppy drive, insert the diskette containing the backup data into the drive on the AWS unit. To access the floppy drive, remove the Control Station front cover and pull back the AWS unit. 7. Click the START button to proceed, and wait for restore completion. 8. A message indicating successful completion appears at the end of the restore procedure. 9. If the IDC data has been restored, the IDC must be rebooted. See section 8-3-1. 10. If the restore is not completed successfully, check the following: • That the backup source is functioning correctly (AWS or floppy disk). • That communication is correct between the AWS and the sub-system being restored. Chapter 7 Page no. 776 JC-ELE-A-052.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A052 - Back-up/Restore Procedure 11. If the Generator data has been restored, the tube heater current must be recalibrated. See section 8-3-2. 8-2 Restore Procedure on V3/V4 Control Stations 1. From the Browser, launch the Service Desktop (see Launching the Service Desktop on page 120). 2. From the Service Desktop, click the Utilities button . 3. Select System Tools > Restore: the Restore screen like the following appears. 4. Select the appropriate restore procedure: you can restore separate sub-system data (AWS, IDC, or Senographe) as required. 5. Select the data source (Backup1 or Backup 2 on the AWS disk or CD-R disk). 6. If restoring from the CD-R disk, insert the CD-R disk containing the backup data into the CD-ROM drive on the AWS unit. 7. A message indicating successful completion appears at the end of the restore procedure. 8. If the IDC data has been restored, the IDC must be rebooted. See section 8-3-1. 9. If the restore is not completed successfully, check the following: • That the backup source is functioning correctly (AWS hard disk or CD-R disk). • That communication is correct between the AWS and the sub-system being restored. 10. If the Generator data has been restored, the tube heater current must be recalibrated. See section 8-3-2. Page no. 777 JC-ELE-A-052.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A052 - Back-up/Restore Procedure 8-3 Post Restore Procedures If you restored the IDC and/or Generator parameters you must perform the post restore procedures described in the following sub-sections. If the language used by the ADS Computer is a different to English, restore the appropriate language according to section 6-3, Set General Configuration Parameters on page 574 in Job Card ELE A013 AWS Configuration. 8-3-1 IDC Post Restore Procedures After IDC data has been restored, the IDC must be rebooted so that it can recognize the changed data. This can be done either by powering OFF/ON, or using a command window. To reboot the IDC using a command window: 1. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 2. Make a telnet connection with the IDC by entering: telnet idc A -> prompt appears. 3. At the ->prompt, reboot the IDC by entering: idcReboot The IDC shuts down and reboots; the message Connection closed by foreign host appears. If you wish to view IDC startup messages you must reconnect by entering the command telnet idc again. The X-ray Console first displays the message S86 AWS/IDC Communication lost, then displays the message S83 Detector environment not OK until the reboot is complete. 8-3-2 Generator Post Restore Procedures After the Generator data has been restored, the heater current must be recalibrated by performing Job Card CAL A012 - X-Ray Tube Heater Current on page 1673. 8-3-3 Stereotaxy Accuracy Check If the system has the Stereotaxy option, please perform accuracy checks described in the Planned Maintenance chapter of the Stereotaxy Operator Manual. Chapter 7 Page no. 778 JC-ELE-A-052.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A052 - Back-up/Restore Procedure 9 BACKUP TROUBLESHOOTING Use the information in the following sections as a guide in troubleshooting backup/restore problems. 9-1 • • Check communication between the AWS and the IDC. Check that there is enough space on the AWS disk to receive the backup data. 9-2 • If AWS Backup to Hard Disk Fails Check that there is enough space on the AWS disk to receive the backup data. 9-3 • • • If IDC Backup Fails If AWS Backup to Floppy Fails on V1/V2 Control Stations Check that the floppy is correctly formatted. Check that the floppy is not damaged. Check that there is enough space on the floppy to receive the backup data. Note: If backup to floppy is not possible, record the AWS parameters manually (see Form LBK A003 Back-up/Restore Procedure - AWS Parameters Manual Record Sheets on page 801). 9-4 • • If AWS Backup to CD-R Fails on V3/V4 Control Stations Check that the CD-R is not damaged. Ensure that the CD-R has not been erased using the CD Erase function, as this is only applicable to CD-RW media and not CD-R media. Note: If the backup to CD-R is not possible, record the AWS parameters manually. See Form LBK A003 - Back-up/Restore Procedure - AWS Parameters Manual Record Sheets on page 801). 9-5 ADS Hard Disk Size Limitations For V1/V2 Control Stations, the hard disk partition where the backup files are located is of limited size. Therefore, only two backup archives on the AWS hard disk are possible before space needs freeing up. For V3/V4 Control Stations, the size of the hard disk partition is far higher. Many backup archives on the AWS hard disk are possible before space needs freeing up. This section describes how to remove the previous backup archives so that a new backup can be performed. If you have to free up disk space to perform a new backup, proceed as follows. 1. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 2. Log in as root as follows: a. At the ADS prompt enter: su -root b. When requested to specify the root password, enter: operator 3. Change to the /export/home/iqst/subsystems/idc/backup directory by entering: Page no. 779 JC-ELE-A-052.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A052 - Back-up/Restore Procedure cd /export/home/iqst/subsystems/idc/backup 4. Delete files in the current IDC backup directories by entering: rm -rf current 5. Delete files in the previous IDC backup directories by entering: rm -rf previous 6. Make a new current IDC backup directory by entering: mkdir current 7. Change the privileges of the current directory to read/write/execute, by entering: chmod 777 current 8. Change the ownership of the current directory to the sdc user, by entering: chown sdc:informix current 9. Make a new current IDC backup directory by entering: mkdir previous 10. Change the privileges of the previous directory to read/write/execute, by entering: chmod 777 previous 11. Change the ownership of the previous directory to the sdc user, by entering: chown sdc:informix previous 12. Perform a new backup (see Backup Procedure on V1/V2 Control Stations on page 774 or Backup Procedure on V3/V4 Control Stations on page 775). Chapter 7 Page no. 780 JC-ELE-A-052.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A060 - Image Receptor Installation Job Card ELE A060 - Image Receptor Installation 1 • Chapter 7 SUPPLIES Image receptor (Digital Detector + Bucky) 2 TOOLS Standard Tool Box 3 REQUIRED EFFORT Personnel: 2 Field Engineers Time: 30 minutes 4 SAFETY PRECAUTIONS WARNING - Power off the Gantry before disconnecting or working on the Digital Detector. - The Digital Detector is cumbersome. Two people are required for installation (see section 6-2, page 782). Follow standard safety practices for handling large components. 5 • • • PRE-REQUISITES The Gantry has been moved to its final position, and secured to the floor if necessary. All procedures likely to require movement and disturbance in the area of the Tube and Image Receptor have been completed. Physical installation, inter-connection and AC connection of the Gantry, Generator Cabinet, and Control Station have been successfully completed. 5-1 Reception The digital detector is delivered on a single pallet, along with the radiation screen, monitor and the accessories. The Gantry and Generator Cabinet are delivered on another pallet. The Control Station is delivered on another pallet. When a Senographe system arrives, check the entire consignment for damage according to Job Card PRE A001 - Checking for Damage on page 371. WARNING Before installing the detector, you must leave it packed for at least one day so that it does not suffer from condensation. Page no. 781 JC-ELE-A-060.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A060 - Image Receptor Installation 6 PROCEDURE Note: The Senographe system is shipped and delivered with the Image Receptor not installed. The system is assembled and calibrated as usual on the manufacturing line. The Image Receptor is then removed from the system and packed in a separate box with additional thermal protection. 6-1 Before Installation of the Digital Detector 1. Turn Gantry power OFF. 2. Remove the Compression and Arm covers (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers, section 8 page 526). 3. Turn Gantry power ON. 4. Set the Arm to an intermediate height. 5. Rotate the arm to between a working position of –45° to + 45°. ! Notice: Never rotate the arm outside of the range –45° to + 45° when installing the Digital Detector. If the coolant pipes are not secured properly and if this arm angle range is not respected, there is a risk of coolant entering the inner workings of the Digital Detector. 6. Turn Gantry power off. 7. Switch off the Conditioner (the Generator covers are currently uninstalled at this stage, so you do not have to remove them to access the Conditioner). 6-2 Installation of Digital Detector CAUTION 1. 2. 3. 4. Two people are required for installation of the Digital Detector. Never allow the mass of the detector to fall onto its alignment pins before the securing screws have been correctly fitted. Before starting to fit the Detector, prepare the securing screws. Apply a small amount of locking compound Loctite 222 to the threads of each screw. While one person holds the detector against its alignment pins on the interface plate, the other fits and tightens the two upper securing screws (1) to hold it in position (5 mm allen wrench, torque 8.5 N.m). Fit and tighten the two lower securing screws (5 mm allen wrench, torque 8.5 N.m). Fit and tighten the screw securing the ground cable terminal (4 mm allen wrench). Chapter 7 1 Page no. 782 JC-ELE-A-060.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A060 - Image Receptor Installation 5. Fit, but do not tighten, the three screws (2) which secure the Bucky interconnection plate (3) to the rear wall plate (4) of the Digital Detector support (3 mm allen wrench). 6. Install temporarily, one after the other, the Bucky, Mag Stand (1,5 and 1,8) and the Stereotactic positioner (if present), to check that they fit. Make any necessary adjustments and tighten the three screws (2). 7. Connect the front connector (5) and secure it using its two screws (flat screwdriver). 8. Connect the fiber-optic cables to their connectors (6) on the Digital Detector connector panel. 2 3 4 7 6 CAUTION Do not apply force to fiber cables; take care not to bend them excessively. 9. Connect the coolant supply pipes (7). 8 5 CAUTION Be careful to avoid spillage of coolant, especially onto or near electrical connections. If any coolant is spilled, it must be cleaned up immediately. 10. Tighten the nuts (8) securing the ground cables (7 mm open ended wrench). 11. Insert the two white caps. 6-3 • • Installation of Bucky Insert the Bucky. Close the two latches, one each side of the Bucky. Page no. 783 JC-ELE-A-060.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A060 - Image Receptor Installation 6-4 Fill the Conditioner with Coolant Liquid CAUTION • Before adding coolant to the Conditioner, always switch off the Generator and MDR circuit breakers in the Generator Cabinet. Switch on the MDR breaker only as instructed. • Always use a funnel when adding coolant to the Conditioner. • Always wear protective gloves and goggles when working with coolant. • When performing the following procedure, be careful to avoid spillage of coolant, especially onto or near electrical connections. If any coolant is spilled, it must be cleaned up immediately. • Always treat coolant with care; avoid unnecessary contact. See below for First Aid advice: First Aid in case of contact with Conditioner coolant: Immediately flush eyes or skin with plenty of water for at least 15 minutes. If coolant contacts the eye, call a physician immediately. If coolant is swallowed, drink one to two glasses of water or milk. Avoid alcohol. Call a physician immediately. Remove and wash contaminated clothing before reuse. Note: A document describing an alternate procedure is provided in the coolant kit. For maximum safety and minimum risk of spillage, General Electric Healthcare recommend using the procedure given below: 1. Check that all hoses are correctly connected. MDR Breaker 2. Remove the reservoir cap. 3. Use the funnel to add slowlyliquid from the container labeled Topping to the reservoir until the liquid ON/OFF reaches the bottom of the cap threads. The total push buttons: capacity of the cooling system is approximately 500 Conditioner Conditioner and ml (1 pint). MDR Take great care to keep coolant away from the Detector supply vents, the ON/OFF switch, and the power cord conControl Station nection. Do not immerse the Conditioner in any liqUPS uid. 4. Switch on the unit (switch on the MDR circuit breaker and press the Conditioner on button in the Generator Generator cabinet). 5. As the coolant circulates and air bubbles are flushed from the system, the coolant level falls. Add liquid as Generator necessary until the level is steady at the bottom of Breaker the cap threads. 6. Replace the reservoir cap when you are satisfied that the level is correct. 7. Dispose of surplus coolant. In a normal non-sensitive environment, you can dispose of surplus coolant by pouring down a drain. Triple-rinse containers before placing them in appropriate waste receptacles. Chapter 7 Page no. 784 JC-ELE-A-060.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A060 - Image Receptor Installation 6-5 • • Install Covers Install the Detector covers (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers, section 10 page 530). Install the Compression and Arm covers (refer to Job Card PHY A044 - Remove/Reinstall Gantry Covers, section 8 page 526). Page no. 785 JC-ELE-A-060.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A060 - Image Receptor Installation This page is blank. Chapter 7 Page no. 786 JC-ELE-A-060.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A065 - Trackball Configuration Job Card ELE A065 - Trackball Configuration 1 Chapter 7 SUPPLIES ADS Trackball Kit 2 APPLICABILITY The trackball is supplied with the V1 Control Station, which is no longer being produced. V2/V3/V4 Control Stations are supplied with a mouse and with the trackball as an option. This Job Card is only applicable if you have chosen to use the optional trackball, and if the trackball does not have a supplier number of the format X-GEUSB-Axxxx. 3 TOOLS None 4 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 10 minutes 5 SAFETY PRECAUTIONS None 6 PRE-REQUISITES It is recommended that you undertake the trackball configuration in a quiet environment. Since the Senographe system makes some considerable noise, you should ideally unplug the trackball from the Senographe system and connect it to your laptop PC in a quiet area. 7 PROCEDURE - TRACKBALL CONFIGURATION 7-1 Trackball Configuration • • • • • Reference numbers used to identify the buttons of the trackball are shown in the illustration. button 4 Trackballs supplied on a new system are correctly configured in button 5 the factory. button 6 Replacement trackballs are supplied as received from the manubutton 1 button 2 facturer, and must be configured. button 3 Before use, check that the trackball buttons are set to be equivalent to mouse buttons, as follows: 1. Check that buttons 1 and 6 are set up for right click. 2. Check that buttons 2 and 5 are set up for middle click. 3. Check that buttons 3 and 4 are set up for left click. A suggested check procedure is given in the Trackball Setup Checks on page 789. If necessary, use the trackball program mode to configure the buttons as described in the Trackball Button Setup Procedures on page 788 Page no. 787 JC-ELE-A-065.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A065 - Trackball Configuration Note: During each configuration procedure, the trackball may "beep" between four and 10 times. If the configuration instruction asks you to wait for the beeping to stop, it is important that no button is pressed before the end of the beep. In each procedure: First press buttons 1 and 6 until the trackball beeps to enter program mode. Press buttons 2 and 5 until the trackball beeps to confirm entry to program mode. To abort the programming operation, press buttons 1 and 6. 7-2 • • • • • Trackball Button Setup Procedures Button 1: Right click 1. Press and hold buttons 1 and 6 until the trackball beeps. 2. Press and hold buttons 2 and 5. Wait until the trackball beeps and ensure that you release both buttons before the beep ends (the beep lasts 2 seconds). 3. Press and release button 1 and wait for the trackball to stop beeping. 4. Press and release button 3 and wait for the trackball to stop beeping. 5. Press and release button 1 and wait for the trackball to stop beeping. Button 2: Middle click 1. Press and hold buttons 1 and 6 until the trackball beeps. 2. Press and hold buttons 2 and 5. Wait until the trackball beeps and ensure that you release both buttons before the beep ends (the beep lasts 2 seconds). 3. Press and release button 2 and wait for the trackball to stop beeping. 4. Press and release button 2 and wait for the trackball to stop beeping. 5. Press and release button 1 and wait for the trackball to stop beeping. Button 3: Left click 1. Press and hold buttons 1 and 6 until the trackball beeps. 2. Press and hold buttons 2 and 5. Wait until the trackball beeps and ensure that you release both buttons before the beep ends (the beep lasts 2 seconds). 3. Press and release button 3 and wait for the trackball to stop beeping. 4. Press and release button 1 and wait for the trackball to stop beeping. 5. Press and release button 1 and wait for the trackball to stop beeping. Button 4: Left click 1. Press and hold buttons 1 and 6 until the trackball beeps. 2. Press and hold buttons 2 and 5. Wait until the trackball beeps and ensure that you release both buttons before the beep ends (the beep lasts 2 seconds). 3. Press and release button 4 and wait for the trackball to stop beeping. 4. Press and release button 1 and wait for the trackball to stop beeping. 5. Press and release button 1 and wait for the trackball to stop beeping. Button 5: Middle click 1. Press and hold buttons 1 and 6 until the trackball beeps. 2. Press and hold buttons 2 and 5. Wait until the trackball beeps and ensure that you release both buttons before the beep ends (the beep lasts 2 seconds). 3. Press and release button 5 and wait for the trackball to stop beeping. 4. Press and release button 2 and wait for the trackball to stop beeping. Chapter 7 Page no. 788 JC-ELE-A-065.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A065 - Trackball Configuration • 5. Press and release button 1 and wait for the trackball to stop beeping. Button 6: Right click 1. Press and hold buttons 1 and 6 until the trackball beeps. 2. Press and hold buttons 2 and 5. Wait until the trackball beeps and ensure that you release both buttons before the beep ends (the beep lasts 2 seconds). 3. Press and release button 6 and wait for the trackball to stop beeping. 4. Press and release button 3 and wait for the trackball to stop beeping. 5. Press and release button 1 and wait for the trackball to stop beeping. 7-3 Trackball Setup Checks The following procedure is suggested as a check for correct trackball setup: 1. Start up the system as usual. 2. With the Browser window displayed on the AWS screen, press the keyboard Front key on V1/V2/V3 Control Stations, or the keyboard Alt + Tab keys together on V4 Control Stations until the Iconbox window appears. 3. Double-click the trackball button 4 to open the Console window. • If the Console window does not open, repeat the setup procedure for button 4. 4. To check that buttons 3 and 4 are correctly set for left click: With the cursor in the Console window, press the keyboard Control key. Keep the Control key pressed while you do each of the following checks: • Press button 3: if the Main Options Menu does not appear, repeat the setup procedure for button 3. • Release button 3: if the Main Options Menu does not close, repeat the setup procedure for button 3. • Press button 4: if the Main Options Menu does not appear, repeat the setup procedure for button 4. • Release button 4: if the Main Options Menu does not close, repeat the setup procedure for button 4. 5. To check that buttons 2 and 5 are correctly set for middle click: With the cursor in the Console window, press the keyboard Control key. Keep the Control key pressed while you do each of the following checks: • Press button 2: if the VT Options Menu does not appear, repeat the setup procedure for button 2. • Release button 2: if the VT Options Menu does not close, repeat the setup procedure for button 2. • Press button 5: if the VT Options Menu does not appear, repeat the setup procedure for button 5. • Release button 5: if the VT Options Menu does not close, repeat the setup procedure for button 5. Page no. 789 JC-ELE-A-065.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A065 - Trackball Configuration 6. To check that buttons 1 and 6 are correctly set for right click: With the cursor in the Console window, press the keyboard Control key. Keep the Control key pressed while you do each of the following checks: • Press button 1: if the VT Fonts Menu does not appear, repeat the setup procedure for button 1. • Release button 1: if the VT Fonts Menu does not close, repeat the setup procedure for button 1. • Press button 6: if the VT Fonts Menu does not appear, repeat the setup procedure for button 6. • Release button 6: if the VT Fonts Menu does not close, repeat the setup procedure for button 6. Chapter 7 Page no. 790 JC-ELE-A-065.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A067 - Repeat and Reject Analysis Configuration Job Card ELE A067 - Repeat and Reject Analysis Configuration 1 Chapter 7 SUPPLIES AWS Application Software CD-ROM 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 10 minutes 4 SAFETY PRECAUTIONS No specific safety precautions are applicable. 5 PREREQUISITES The Repeat and Reject Analysis feature must have been installed, and the installation step Reset Repeat & Reject Analysis OK must have been performed. In the booklet supplied with the AWS Application Software CD, refer to the last step of Install from Scratch or Update from CD-ROM. 6 PROCEDURE 1. Discuss the required configuration of the Repeat and Reject Analysis feature with the customer. 2. Before activating the feature, ensure that all names held on the system for technologists who are concerned with this feature are correctly entered. ! Notice: Check that no name includes unwanted blank characters. Data for any technologists whose name contains two or more consecutive blank characters are not taken into account for the analysis. 3. Activate and configure the Repeat and Reject Analysis feature. Instructions are given in the Senographe DS Operator Manual. Refer to the Browser chapter and locate the section Tools menu utilities - Medical Application preferences - Quality Check. Page no. 791 JC-ELE-A-067.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A067 - Repeat and Reject Analysis Configuration This page is blank. Chapter 7 Page no. 792 JC-ELE-A-067.fm GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A071 - Installation of CAD option on AWS Job Card ELE A071 - Installation of CAD option on AWS 1 Chapter 7 SUPPLIES None 2 TOOLS None 3 REQUIRED EFFORT Personnel: 1 Field Engineer Time: 10 minutes 4 SAFETY PRECAUTIONS None 5 PREREQUISITES None 6 PROCEDURE 6-1 Installation of the CAD Button on AWS 1. From behind the Browser, launch a command window (see Launching a Command Line Window on page 120). A command window appears with an ADS prompt. 2. In the command window, run the install.cad script, by entering: install.cad 3. When requested to specify the root password, enter: operator Once the installation is complete the following message appears: install.cad: Installation complete 4. Close the command window, by entering: exit Page no. 793 JC-ELE-A-071.fm Chapter 7 GE Healthcare Revision 1 Senographe DS Service Information and Procedures Class A 2385072-16-8EN Job Card ELE A071 - Installation of CAD option on AWS 6-2 Declaration of the CAD option on the AWS 1. From the Browser, launch the Service Desktop (see Launching the Service Desktop on page 120). 2. Access the CAD Home Page as follows: • For V1/V2 Control Stations, from the Service Desktop, click the CAD button . • For V3/V4 Control Stations, from the Service Desktop, click the Utilities button . Then from the Utilities page that appears, click the CAD icon to expand the CAD tree and then click the CAD icon that is revealed. The CAD Home page appears. Note: If existing CAD Units have already been declared, the CAD Home page lists the name, IP address, and Hostname for each of the already declared CAD Units. 3. From the CAD Home Page, click the ADD button. 4. The bottom part of the CAD Home Page updates with the following three fields, allowing you to declare the new CAD Unit: • In the Label field, enter the name to be used to identify the CAD Unit in the Service desktop (e.g. iCAD_SLDU). If the same CAD Unit is declared on more than one AWS, it is recommended that the same name should be used on each AWS, to avoid confusion. • In the IP address field, enter the IP address allocated to the CAD Unit. • In the Hostname field, enter the hostname allocated to the CAD Unit (typically in the form SLD