5456324 1-3 CFC_24VDC_HD PWA by GE CT - 5456324-3 CFC_24VDC_HD PWA by GE CT

GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.Please note, cuffs, BP items, sterile and hazmat items cannot be returned. If a replacement order is requested, the restocking fee may be waived at GE HealthCare’s sole discretion.
The 16 Slice Global Data Acquisition System (GDAS) Converter Card is used in CT scanners and other medical systems. It is a printed circuit board which processes low level current signals from 128 channels of CT X-ray detector photodiode and convert them into 128 voltage/charge signals. This circuit board is comprised of a 2 GDAS ASICs, 32-bit floating point DSP, 100uA bias current circuit for the GDAS ASICs, GDAS ASIC Bridge (GAB) FPGA, CAN Transceiver, I2C serial digital output temperature sensor, bootable 16 Mbit flash memory, 128 Mbit SDRAM ICs, regulators, local ferrite beads, and digital I/O circuitry. The signal from detector output is amplified by the GDAS ASIC. The flash memory holds the necessary ASICs input offset voltage trim values, firmware version, date, time, vector table, checksum, FPGA configuration file and the converter board serial number. The on board temperature sensor (U5) monitors the board ambient temperature to ensure that the board is operating in its proper temperature range. The converter board shall not constitute a safety hazard to personnel using or maintaining the CT equipment. The product is securely packaged inside a high quality packing box to avoid physical damage during transit.
Don't know your approval number? Call 800-437-1171Enter opt 1 for the first three prompts, and have your System ID available.If you add item(s) to cart and submit your order without selecting an approver, GE will contact you before your order can be confirmed for shipment.
Time is valuable when it comes to patient care. Service Shop, from GE HealthCare, makes ordering faster and easier than ever before, so you can focus on what matters the most - patient care.
You have accepted a quote and it is currently available in your cart. Please complete the order processing to add an item to the cart.
The 16 Slice Global Data Acquisition System (GDAS) Converter Card is used in CT scanners and other medical systems. It is a printed circuit board which processes low level current signals from 128 channels of CT X-ray detector photodiode and convert them into 128 voltage/charge signals. This circuit board is comprised of a 2 GDAS ASICs, 32-bit floating point DSP, 100uA bias current circuit for the GDAS ASICs, GDAS ASIC Bridge (GAB) FPGA, CAN Transceiver, I2C serial digital output temperature sensor, bootable 16 Mbit flash memory, 128 Mbit SDRAM ICs, regulators, local ferrite beads, and digital I/O circuitry. The signal from detector output is amplified by the GDAS ASIC. The flash memory holds the necessary ASICs input offset voltage trim values, firmware version, date, time, vector table, checksum, FPGA configuration file and the converter board serial number. The on board temperature sensor (U5) monitors the board ambient temperature to ensure that the board is operating in its proper temperature range. The converter board shall not constitute a safety hazard to personnel using or maintaining the CT equipment. The product is securely packaged inside a high quality packing box to avoid physical damage during transit.
GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.Please note, cuffs, BP items, sterile and hazmat items cannot be returned. If a replacement order is requested, the restocking fee may be waived at GE HealthCare’s sole discretion.

Customer agrees that products purchased from the GE HealthCare Service Shop will only be used in operating and servicing medical equipment at a healthcare facility located in the United States in which it was intended, and will not be otherwise used for manufacturing, resale or other distribution.
Don't know your approval number? Call 800-437-1171Enter opt 1 for the first three prompts, and have your System ID available.If you add item(s) to cart and submit your order without the approval number, GE will contact you before your order can be confirmed for shipment.

Neil
Neil