Sonositelogo

Google Analytics cookies help us improve the performance of the website by understanding how visitors use the site.We recommend you set these 'ON'.

For advanced obstetric applications, a vaginal transducer (ICT x/ 8-5MHz) can be ordered separately (see accessories). This transducer is intended for trained and experienced users. It must always be used with a male condom.

After each examination, it must be cleaned and disinfected with a 0.5% detergent-disinfectant solution for medical equipment (either 25 ml = 1 stroke of dosing pump for 5 liters of water).

Sonositeultrasound portable

In using Google Analytics, we do not collect or store personal information that could identify you (for example your name or address). We do not allow Google to use or share our analytics data. Google has developed a tool to help you opt out of Google Analytics cookies.

SonositePX

**Only 0.5% Anios Clean diluted solution, made fresh daily, should be used to clean transducers. This is required after EVERY patient exam. Surfanios is NOT approved as a cleaning solution and may damage the transducers. NEVER use alcohol or oil based products (Sterilium, povidone-iodine, alcohol gel, gel cleansers) as these may damage the transducer.

It is mandatory to protect the device with a double conversion UPS, and a voltage limiter with timer (see related articles below)

Ultrasound-based diagnostic imaging apparatus used to visualize subcutaneous body structures. High image quality for abdominal, nerve, vascular, cardiac, venous access, pelvic and superficial imaging.

These cookies enable the website to function properly. You can only disable these by changing your browser preferences, but this will affect how the website performs.

SonositeEdge

Our mission is to provide lifesaving medical care to those most in need. MSF provides assistance to populations in distress, to victims of natural or man-made disasters, and to victims of armed conflict.

Transducer needs vary by project site. To order the most suitable transducers for your site, please contact POCUS@msf.org or the POCUS advisor for further advice.

Sonositeultrasound

This high-resolution ultrasound system offers such performance features as larger cart-based systems in a hand-carried, stand-alone unit.

Cf https://msfintl.sharepoint.com/sites/msfintlcommunities/pocus/TIC/Forms/AllItems.aspx?csf=1&web=1&e=ORc1q2&cid=9f78c21b%2D1a90%2D4478%2Db725%2D1dd9ec6bb5dc&RootFolder=%2Fsites%2Fmsfintlcommunities%2Fpocus%2FTIC%2F2023%20BioMed%20Briefing%20and%20Sessions&FolderCTID=0x0120005CCD79C1461B264790B1478C06A0D076

If a patient shows infectious lesions, the end of the transducer must be covered with a male condom or glove during the examination.

Sonositeultrasound price

It appears that your web browser does not support JavaScript, or you have temporarily disabled scripting. Either way, this site won't work without it. Please take a look at how to enable javascript for more help.

Sonositeultrasound machine

Summary: We cannot investigate Miss X’s complaint that the Council has failed to provide court ordered therapy for her daughter because it lies outside our jurisdiction. The law prevents us from investigating matters that are being, or have been, considered in court proceedings. We have no discretion to do so.

If gel is not readily available, it can be replaced with water. Never use alcohol, oil or any other fluids as they can damage the transducer.

*Ultrasound exams are not possible without gel! Please order months in advance, and recommend ordering more than necessary until exact usage/month is well known. This gel has a long shelf-life with no temperature requirements. NEVER use alcohol or oil based products (Sterilium, povidone-iodine, alcohol gel, gel cleansers) as these may damage the transducer. Sterile lubrication or plain WATER may be used as alternatives.

Stopped in 2023 because this model is no longer produced. It is replaced by the Edge 2 from Sonosite (see "replaced by" at bottom of the page)