The Impulse 6000D Defibrillator Analyzer and Impulse 7000DP Defibrillator/Transcutaneous Pacer Analyzer Test Systems are rugged, portable precision test instruments that ensure proper operation and ultimate performance of critical life-support cardiac-resuscitation equipment.

In conjunction with an Impulse 7000DP, the Impulse 7010 Defibrillator Selectable Load Accessory provides multiple loads of 25 Ω, 50 Ω, 75 Ω, 100 Ω, 125 Ω, 150 Ω, 175 Ω, and 200 Ω for defibrillator performance testing. A standard USB interface enables computer control and data transfer, and optional Ansur PC-based automation software increases productivity by outfitting users with an easy-to-use method to standardize testing procedures and capture, print and document data.

• Impulse 7010 Defibrillator Selectable Load Accessory provides multiple loads of 25 Ω, 50 Ω, 75 Ω, 100 Ω, 125 Ω, 150 Ω, 175 Ω, and 200 Ω to comply with IEC 60601-2-4 standard (optional) • Lown, Edmark, trapezoidal, biphasic and pulsed-biphasic defibrillation technology compatibility • AED technology compatibility • First-class measurement accuracy ± 1 % of reading + 0.1 J • Intuitive user interface and backlight, easy-to-read display • Portable, rugged, easy to carry • Long-lasting, rechargeable battery • Pacer brand selections • Pacer input protected against defibrillator output (7000DP only) • 10 independent ECG outputs that provide 12 lead combinations for standardized clinical signals • Flexible heart-rate settings (1 BPM step) facilitate rate meter accuracy and alarm testing • DSP-based measurements enable future firmware and waveforms upgrade • Unique integrated posts for secure connections • Two-year extended warranty (no-cost extended warranty available after first-year calibration at any Fluke Biomedical authorized service center) • Optional Ansur test automation software to standardize testing procedures, capture waveforms and test results, and print and document test results • Designed, tested, and built to incomparable Fluke quality standards

The Impulse 6000D and Impulse 7000DP test capabilities encompass the spectrum of worldwide established pulse shapes, showcase breakthrough AED technology compatibility, and outperform in accuracy and standards. Additionally, the Impulse 7000DP incorporates the tests and the extensive range of test loads and measurement algorithms needed to test external transcutaneous pacemakers.

RTCI – Réchauffement Thermique Cote d’Ivoire Adresse: Rue Lumière, Face à Saprolait – Zone 4C Marcory – 30 BP 836 Abidjan 30 – Cote d’Ivoire

Hello! Please let me know your question about this opportunity. I will answer based on the related documents for this opportunity.

Place your question(s) below. One of our analysts will anonymously submit the question(s) within 8 hours and provide any responses via email once received. Incumbent Award Status