Inspection includes a pressure and flow test of the pump. A visual inspection of all internal pipes and cables, function check of warning lamps and switches, cleaning or replacement of filters.

Inspection includes a check of the condition of the water reservoir seal, function of hand and foot control and variable water pressure control.

Dorset Nursing Supplies Ltd. Unit 4A, Wilverley Road, Somerford Christchurch, BH23 3RU Telephone: 01202 425070 Whatsapp: +44 1202 425070

Inspection includes a check of the function, condition and calibration of the actuator and variable timing mechanism. Conditions of syringe mountings, battery connections and voltages.

Inspection includes a visual check to determine the security of all stitching, sling fabric and mounting tags. It is recommended that this inspection is carried out at six monthly intervals.

Inspection includes a visual check and lubrication of all tilt mechanisms, all pivots and bushes, the adjustment of all operating cables. Hydraulic mechanisms operation and security. Electric models all functions and electrical safety checked. All castors are examined to determine their condition and the operation of brakes. A complete check of the couch frame for fractures and a summary is provided of the couch's general condition.

Inspection includes a check of the condition of all hoses, internal exhaust bottle and suction and flow test of the pump. Function of all warning lamps, non-return valves and filter.

Our qualified engineers will inspect, service and repair items, including (but not limited to) hoists, beds and sluice machines for Care Homes and ECG machines, Couches, Ear Syringes and Pulse Oximeters for Surgeries. We also calibrate measuring devices such as blood pressure monitors and scales. Much of the work can be carried out on site (Dorset and much of Hampshire - other areas, please enquire) or, if necessary, repairs can be carried out at the Wilverley Road workshop.

For more details please see below or if you would like to discuss your equipment requirements please contact us via email: engineers@dorsetnursing.co.uk or alternatively you can call us on: 01202 425070

Inspection includes checks of the fill water temperature, condition operation and security of hydraulic and/or electrical system. Operation of door, gas strut and condition of door seals. Security of all mountings and grab handles, general condition of bath and internal surfaces. Lubricate pivots and hinges. A test of electrical safety and the function of all warning lights.

Medical equipmentrepair jobs

Inspection includes checks of the condition and security of all seat mounting points, safety straps and bath mounting pads. The condition of all gaiter and covers. The operation and security of all pivots, an inspection of the frame for cracks or damage and all bolts for security. The operation of all powered functions and a check of the battery chargers functions. A specific test load is applied and an over all condition report produced.

Includes external examination of all leads and connections, Inspection of filters and complete calibration and function check.

medical equipment repairs nearlondon

Inspection includes an examination of all electrical cables and vacuum hoses, function of all indicator lamps and drills speed controls and drill check. Clean or replace all filters and dust collection bags.

Medical equipmentservicing

Inspection includes checks of the security and condition of spreader bar and attachment clips, mast box and chassis, boom and mast mounting bolts. Function and condition of hydraulic or electrical actuator and controls. Operation of leg adjustment, the condition of the castors and operation of the castor brakes. Function of the battery charger and a check of the security of all bolts and fixings. Application of specific test load. It is recommended that this inspection is carried out at six monthly intervals.

Inspection includes a check of the security of all seat mountings, operation of brakes, balance arm links and locks balance arm adjuster. Lubrication of wheels and castors and the adjustment of base plate feet. Calibration of scales using test weights.

Inspection includes a visual check of water levels, operating temperatures, cycle times and thermostat functions. Condition of water pump seals, water tank ball valve, spray bar and all pipe work. A test of electrical safety and the function of all warning lights.

Exklusiv für Gewerbetreibende Jetzt auf mehr als 1.500 Produkte zugreifen. Kein Gewerbekunde? Jetzt im Privatkunden Online Shop einkaufen.

Additionally, DNS Engineering offers PAT testing to ensure that all your electrically operated devices comply with relevant legislation.

Inspection includes a physical and full electrical test of all patient cables leads and electrodes. Complete function test using an input simulator. Printer head cleaning and a machine configuration test.

Includes an examination of the condition of the unit and mains supply cable. Full leakage test at maximum operating power.

Inspection includes a check of the operation and security of balance arm links and balance arm locks. Clean and lubricate all pivots and coupling arms. Calibration check using test weights.

Inspection includes a check of the condition of all hoses, the armband, hand pump and deflation valve. Calibration of the gauge.

Inspection includes checks of all seat mounting points, safety straps, boom and fittings, floor mounting plate fixing bolts, mast-locking mechanisms. Function and condition of hydraulic or mechanical actuator. Application of specific test load and a check of the security of all bolts and fixings. It is recommended that this inspection is carried out at six monthly intervals.

Inspection includes: Pump: Function and condition al all indicator lamps, timer or channel control valves, all pipes, pump output and comfort control range. Inspection of filters and pump bellows. Mattress: Inspection of condition and security of all inflation cells.

Inspection includes a check of all chair functions, the security of all mountings, pivots, fixings and cables and a general report on the chair's overall condition. Electric functions and safety checked.

Inspection includes checks of all mounting points, webbing for wear and fraying, mounting catch and safety clip, winch mountings, hanging web and safety catch. Operation of all electrical functions, emergency lowering control, the state and charge of battery and charger when installed. Application of test load and a check of the security of all bolts and fixings. It is recommended this inspection is carried out at six monthly intervals.

Check all electrical functions, temperatures, spray intensity, seat and fixings. Test air temperatures and controls. Check water reservoir condition and water tank ball valve. Check all pipework. Test ventilating system.

medical equipment repairs nearmanchester

Inspection includes a check of the operation, cleaning and lubrication of all pivots and coupling arms, condition of batteries and charger. Calibration using test weights.

Inspection includes a check of the condition of all hoses, armbands digital display panels and individual battery voltages. The calibration of the maximum and minimum pressure settings, the functions of the pump and auto pressure release.

Inspection includes a check of the operation of all locking mechanisms. Adjustment of brakes, wheel bearings and tyre pressures. Condition of tyres, front swivels, seat and backrest fabric, footrests, retaining straps, arm rests and side plates. Lubricate all pivots and bearings and tighten all bolts.

Inspection includes a visual check and lubrication of all tilt mechanisms, all pivots and bushes, the adjustment of all operating cables, operation and security of back rest. Hydraulic mechanisms operation and security. All castors are examined to determine their condition and the operation of brakes. A complete check of the bed frame for fractures and a summary is provided of the beds general condition.