Evacuated container meaning

Image

You have already flagged this document.Thank you, for helping us keep this platform clean.The editors will have a look at it as soon as possible.

What is an Evacuated Container used for

By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU.

This ePaper is currently not available for download.You can find similar magazines on this topic below under ‘Recommendations’.

Baxter

Instructions for Use: SonoCheck TMBrand Name of ProductGeneric Name of ProductProduct Code Number(s)Purpose of ProductRange of Applications for ProductKey specifications of productShipping Conditions & RequirementsStorage ConditionsPackaging ConditionsShelf LifeSonocheck TM Ultrasonic Function TestDosimeter for cavitation energy in an ultrasonic bath.TI-108To provide a pass/fail detection of cavitation energy within an ultrasonic bath.Table top ultrasonic, MIS instrument cleaners utilizing ultrasonic cleaning, automatedinstrument washers with an ultrasonic bath stage.Color change from blue/green to yellow indicates cavitation energy is present.Shipping & StorageDo not allow to freeze.35 o F (2 o C) – 77 o F (25 o C). Do not allow to freeze.30 Sonocheck test vials per box12 months from date of manufacture. See package label for expiration date.Instructions for Using ProductDescription of Use (s)To test for the presence of cavitation energy inside of an ultrasonic bath. May be used forqualification testing after initial installation and after major repair, as well as for routinetesting to insure proper performance.Preparation for Use 1. Prepare a bath of cleaning solution (water and detergent) in compliance withinstructions for use by the sonic manufacturer and the detergent manufacturer.2. De-gas the bath in accordance with ultrasonic manufacturer’s instructions.3. Insure that the bath is within the proper temperature range as provided by the detergentmanufacturer.Diagrams (drawings, pictures): Small Tank Medium Tank Large Tankxxxxxx x xx x xx x xFigure 1 (Qualification Testing)Small tank= Up to 5 ltrsMedium tank=5 to 20 ltrsLarge=Above 20 ltrsx x x xx x x xx x x xSmall Tank Medium Tank Large Tankx x x x x xFigure 2 (Routine Testing)Steps for Use of ProductFigure 3 (color change)Routine Testing:1. Select the appropriate number of SonoCheck TM vials and as depicted in Figure 2 tochoose the layout that matches the size of the equipment to be tested.2. Place the SonoChecks as indicated in Figure 2 in an empty ultrasonic basket and placethe basket in the ultrasonic cleaner that has been de-gassed.3. Run the equipment as directed by the ultrasonic manufacturer and record the testresults on the “Log Sheet” located on hmark.com.4. All SonoChecks should change from blue/green to yellow (see Figure 3) withinspecified time. The time needed for the color change will indicate the level of energyand degree of cavitation provided by the ultrasonic cleaner. A change slower than average will indicate a weak spot. A negative result will indicate a blind spot of ultrasonic energy.5. In case of an unsatisfactory result, refer to the SonoCheck TM troubleshooting guide.

Image